An unspecified script in the web interface in Cisco Firepower Extensible Operating System 1.1(1.160) on Firepower 9000 devices allows remote authenticated users to execute arbitrary OS commands via crafted parameters, aka Bug ID CSCux10622.
OS command injection in user.cgi in ASUSTOR ADM version 3.1.1 allows attackers to execute system commands as root via the "name" POST parameter.
OS command injection in group.cgi in ASUSTOR ADM version 3.1.1 allows attackers to execute system commands as root by modifying the "name" POST parameter.
A command injection vulnerability in PWS in Imperva SecureSphere 13.0.0.10 and 13.1.0.10 Gateway allows an attacker with authenticated access to execute arbitrary OS commands on a vulnerable installation.
Dell EMC Data Protection Advisor 6.4, 6.5 and 18.1 contain an OS command injection vulnerability. A remote authenticated malicious user may exploit this vulnerability to execute arbitrary commands on the affected system.
The Patient Portal of OpenEMR 5.0.2.1 is affected by a Command Injection vulnerability in /interface/main/backup.php. To exploit the vulnerability, an authenticated attacker can send a POST request that executes arbitrary OS commands via shell metacharacters.
OS command injection in user.cgi in ASUSTOR ADM version 3.1.1 allows attackers to execute system commands as root via the "secret_key" URL parameter.
OCS Inventory 2.4.1 is prone to a remote command-execution vulnerability. Specifically, this issue occurs because the content of the ipdiscover_analyser rzo GET parameter is concatenated to a string used in an exec() call in the PHP code. Authentication is needed in order to exploit this vulnerability.
IBM Spectrum Scale and IBM Spectrum Protect Plus 10.1.0 through 10.1.5 could allow a remote authenticated attacker to execute arbitrary commands on the system. By sending a specially crafted request, an attacker could exploit this vulnerability to execute arbitrary commands on the system. IBM X-Force ID: 175419.
IBM Spectrum Protect Plus 10.1.0 through 10.1.5 could allow a remote attacker to execute arbitrary commands on the system in the context of root user, caused by improper validation of user-supplied input. IBM X-Force ID: 174966.
LINK-NET LW-N605R devices with firmware 12.20.2.1486 allow Remote Code Execution via shell metacharacters in the HOST field of the ping feature at adm/systools.asp. Authentication is needed but the default password of admin for the admin account may be used in some cases.
IBM Spectrum Scale and IBM Spectrum Protect Plus 10.1.0 through 10.1.5 could allow a remote authenticated attacker to execute arbitrary commands on the system. By sending a specially crafted request, an attacker could exploit this vulnerability to execute arbitrary commands on the system. IBM X-Force ID: 175418.
The network diagnostic function (ping) in the Yeahlink Ultra-elegant IP Phone SIP-T41P (firmware 66.83.0.35) allows a remote authenticated attacker to trigger OS commands or open a reverse shell via command injection.
NETGEAR NMS300 devices before 1.6.0.27 are affected by command injection by an authenticated user.
A Command Injection issue in the traceroute feature on TP-Link TL-WR841N V13 (JP) with firmware versions prior to 201216 allows authenticated users to execute arbitrary code as root via shell metacharacters, a different vulnerability than CVE-2018-12577.
Arbitrary command execution can occur in Webmin through 1.962. Any user authorized for the Package Updates module can execute arbitrary commands with root privileges via vectors involving %0A and %0C. NOTE: this issue exists because of an incomplete fix for CVE-2019-12840.
A vulnerability in the web-based management interface of Cisco Small Business RV110W, RV130, RV130W, and RV215W Series Routers could allow an authenticated, remote attacker to inject arbitrary shell commands that are executed by an affected device. The vulnerability is due to insufficient input validation of user-supplied data. An attacker could exploit this vulnerability by sending a crafted request to the web-based management interface of an affected device. A successful exploit could allow the attacker to execute arbitrary shell commands or scripts with root privileges on the affected device.
A low-privileged remote attacker could exploit the vulnerability and inject additional system commands via file system libraries which could give the attacker full control of the device.
Belkin LINKSYS RE6500 devices before 1.0.012.001 allow remote authenticated users to execute arbitrary commands via shell metacharacters in a filename to the upload_settings.cgi page.
cups-filters contains backends, filters, and other software required to get the cups printing service working on operating systems other than macos. If you use the Backend Error Handler (beh) to create an accessible network printer, this security vulnerability can cause remote code execution. `beh.c` contains the line `retval = system(cmdline) >> 8;` which calls the `system` command with the operand `cmdline`. `cmdline` contains multiple user controlled, unsanitized values. As a result an attacker with network access to the hosted print server can exploit this vulnerability to inject system commands which are executed in the context of the running server. This issue has been addressed in commit `8f2740357` and is expected to be bundled in the next release. Users are advised to upgrade when possible and to restrict access to network printers in the meantime.
A vulnerability in the web UI of Cisco Integrated Management Controller (IMC) could allow an authenticated, remote attacker to inject arbitrary code and execute arbitrary commands at the underlying operating system level. The vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by sending crafted commands to the web-based management interface of the affected software. A successful exploit could allow the attacker to inject and execute arbitrary commands at the underlying operating system level.
D-Link DSL-3782 v1.03 and below was discovered to contain a command injection vulnerability via the function byte_4C0160.
Belkin LINKSYS RE6500 devices before 1.0.11.001 allow remote authenticated users to execute arbitrary commands via goform/systemCommand?command= in conjunction with the goform/pingstart program.
A vulnerability in the Device Manager application of Cisco Data Center Network Manager (DCNM) could allow an authenticated, remote attacker to inject arbitrary commands on the affected device. The vulnerability is due to insufficient validation of user-supplied input. An attacker could exploit this vulnerability by sending crafted arguments to a specific field within the application. A successful exploit could allow the attacker to run commands as the administrator on the DCNM.
A vulnerability was found in Byzoro Smart S85F Management Platform up to 20231010 and classified as critical. This issue affects some unknown processing of the file /sysmanage/importconf.php. The manipulation of the argument btn_file_renew leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-243059. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
An OS command injection vulnerability in FortiDeceptor 3.1.0, 3.0.1, 3.0.0 may allow a remote authenticated attacker to execute arbitrary commands on the system by exploiting a command injection vulnerability on the Customization page.
Quest DR Series Disk Backup software version before 4.0.3.1 allows command injection (issue 8 of 46).
Quest DR Series Disk Backup software version before 4.0.3.1 allows command injection (issue 35 of 46).
Quest DR Series Disk Backup software version before 4.0.3.1 allows command injection (issue 33 of 46).
Quest DR Series Disk Backup software version before 4.0.3.1 allows command injection (issue 32 of 46).
A vulnerability in the web-based user interface (web UI) of Cisco IOS XE Software could allow an authenticated, remote attacker with read-only privileges to inject IOS commands to an affected device. The injected commands should require a higher privilege level in order to be executed. The vulnerability is due to insufficient input validation of specific HTTP requests. An attacker could exploit this vulnerability by sending crafted HTTP requests to a specific web UI endpoint on an affected device. A successful exploit could allow the attacker to inject IOS commands to the affected device, which could allow the attacker to alter the configuration of the device or cause a denial of service (DoS) condition.
Quest DR Series Disk Backup software version before 4.0.3.1 allows command injection (issue 40 of 46).
Quest DR Series Disk Backup software version before 4.0.3.1 allows command injection (issue 12 of 46).
The Bosch Ethernet switch PRA-ES8P2S with software version 1.01.05 and earlier was found to be vulnerable to command injection through its diagnostics web interface. This allows execution of shell commands.
On D-Link DIR-550A and DIR-604M devices through v2.10KR, a malicious user can forge an HTTP request to inject operating system commands that can be executed on the device with higher privileges, aka remote code execution.
Quest DR Series Disk Backup software version before 4.0.3.1 allows command injection (issue 28 of 46).
Quest DR Series Disk Backup software version before 4.0.3.1 allows command injection (issue 42 of 46).
Quest DR Series Disk Backup software version before 4.0.3.1 allows command injection (issue 19 of 46).
Quest DR Series Disk Backup software version before 4.0.3.1 allows command injection (issue 34 of 46).
Maxum Rumpus 8.2.13 and 8.2.14 is affected by a command injection vulnerability. The web administration contains functionality in which administrators are able to manage users. The edit users form contains a parameter vulnerable to command injection due to insufficient validation.
Quest DR Series Disk Backup software version before 4.0.3.1 allows command injection (issue 2 of 46).
Quest DR Series Disk Backup software version before 4.0.3.1 allows command injection (issue 18 of 46).
The '/common/ajax_email_connection_test.php' script in the Quest KACE System Management Appliance 8.0.318 is accessible by any authenticated user and can be abused to execute arbitrary commands on the system. This script is vulnerable to command injection via the unsanitized user input 'TEST_SERVER' sent to the script via the POST method.
Quest DR Series Disk Backup software version before 4.0.3.1 allows command injection (issue 24 of 46).
Quest DR Series Disk Backup software version before 4.0.3.1 allows command injection (issue 37 of 46).
RUCKUS SmartZone (SZ) before 6.1.2p3 Refresh Build allows OS command injection via a certain parameter in an API route.
Quest DR Series Disk Backup software version before 4.0.3.1 allows command injection (issue 25 of 46).
An issue was discovered on D-Link DSR-250 3.17 devices. Certain functionality in the Unified Services Router web interface could allow an authenticated attacker to execute arbitrary commands, due to a lack of validation of inputs provided in multipart HTTP POST requests.
Quest DR Series Disk Backup software version before 4.0.3.1 allows command injection (issue 15 of 46).
An issue was discovered in EyesOfNetwork 5.3 through 5.3-8. An authenticated web user with sufficient privileges could abuse the AutoDiscovery module to run arbitrary OS commands via the nmap_binary parameter to lilac/autodiscovery.php.