An Uncontrolled Search Path Element issue was discovered in Advantech WebAccess versions prior to V8.2_20170817. A maliciously crafted dll file placed earlier in the search path may allow an attacker to execute code within the context of the application.
Cross-site request forgery (CSRF) vulnerability in Advantech WebAccess before 8.1 allows remote attackers to hijack the authentication of unspecified victims via unknown vectors.
In Advantech WebAccess HMI Designer Version 2.1.9.23 and prior, processing specially crafted MCR files lacking proper validation of user supplied data may cause the system to write outside the intended buffer area, allowing remote code execution.
In WebAccess/SCADA Versions 8.3.5 and prior, multiple out-of-bounds write vulnerabilities are caused by a lack of proper validation of the length of user-supplied data. Exploitation of these vulnerabilities may allow remote code execution.
Processing specially crafted .pm3 files in Advantech WebAccess HMI Designer 2.1.7.32 and prior may cause the system to write outside the intended buffer area and may allow remote code execution.
Heap-based buffer overflow vulnerabilities in Advantech WebAccess HMI Designer 2.1.7.32 and prior caused by processing specially crafted .pm3 files may allow remote code execution.
WPLSoft in Delta Electronics versions 2.45.0 and prior utilizes a fixed length heap buffer where a value larger than the buffer can be read from a file into the buffer, causing the buffer to be overwritten, which may allow remote code execution or cause the application to crash.
WPLSoft in Delta Electronics versions 2.45.0 and prior utilizes a fixed length stack buffer where a value larger than the buffer can be read from a file into the buffer, causing the buffer to be overwritten, which may allow remote code execution or cause the application to crash.
WebAccess Versions 8.3.2 and prior. The application fails to properly validate the length of user-supplied data, causing a buffer overflow condition that allows for arbitrary remote code execution.
LCDS Laquis SCADA prior to version 4.1.0.4150 allows taking in user input without proper sanitation, which may allow an attacker to execute remote code on the server.
Several use after free vulnerabilities have been identified in CX-Supervisor (Versions 3.42 and prior). When processing project files, the application fails to check if it is referencing freed memory. An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application.
NetComm Wireless G LTE Light Industrial M2M Router (NWL-25) with firmware 2.0.29.11 and prior. A cross-site request forgery condition can occur, allowing an attacker to change passwords of the device remotely.
Stack-based buffer overflow in Advantech WebAccess (formerly BroadWin WebAccess) 7.2 allows remote attackers to execute arbitrary code via the GotoCmd parameter.
Stack-based buffer overflow in Advantech WebAccess (formerly BroadWin WebAccess) 7.2 allows remote attackers to execute arbitrary code via the AccessCode parameter.
Stack-based buffer overflow in Advantech WebAccess (formerly BroadWin WebAccess) 7.2 allows remote attackers to execute arbitrary code via the password parameter.
Stack-based buffer overflow in Advantech WebAccess (formerly BroadWin WebAccess) 7.2 allows remote attackers to execute arbitrary code via the projectname parameter.
Stack-based buffer overflow in Advantech WebAccess (formerly BroadWin WebAccess) 7.2 allows remote attackers to execute arbitrary code via the NodeName parameter.
The TextEditor 2.0 in ABB CP400 Panel Builder versions 2.0.7.05 and earlier contain a vulnerability in the file parser of the Text Editor wherein the application doesn't properly prevent the insertion of specially crafted files which could allow arbitrary code execution.
A type confusion vulnerability exists when processing project files in CX-Supervisor (Versions 3.42 and prior). An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application.
Stack-based buffer overflow in Advantech WebAccess (formerly BroadWin WebAccess) 7.2 allows remote attackers to execute arbitrary code via the UserName parameter.
Stack-based buffer overflow in Advantech WebAccess (formerly BroadWin WebAccess) 7.2 allows remote attackers to execute arbitrary code via the AccessCode2 parameter.
In ABB IP GATEWAY 3.39 and prior, the web server does not sufficiently verify that a request was performed by the authenticated user, which may allow an attacker to launch a request impersonating that user.
A Stack-based Buffer Overflow issue was discovered in Advantech WebAccess versions prior to V8.2_20170817. The application lacks proper validation of the length of user-supplied data prior to copying it to a stack-based buffer, which could allow an attacker to execute arbitrary code under the context of the process.
A heap-based buffer overflow issue was discovered in Advantech WebAccess versions prior to V8.2_20170817. Researchers have identified multiple vulnerabilities where there is a lack of proper validation of the length of user-supplied data prior to copying it to the heap-based buffer, which could allow an attacker to execute arbitrary code under the context of the process.
An Externally Controlled Format String issue was discovered in Advantech WebAccess versions prior to V8.2_20170817. String format specifiers based on user provided input are not properly validated, which could allow an attacker to execute arbitrary code.
Opening a maliciously crafted project file may cause an out-of-bounds write, which may allow an attacker to execute arbitrary code. User interaction is require on the WebAccess HMI Designer (versions 2.1.9.95 and prior).
The affected product is vulnerable to memory corruption condition due to lack of proper validation of user supplied files, which may allow an attacker to execute arbitrary code. User interaction is required on the WebAccess HMI Designer (versions 2.1.9.95 and prior).
Parsing a maliciously crafted project file may cause a heap-based buffer overflow, which may allow an attacker to perform arbitrary code execution. User interaction is required on the WebAccess HMI Designer (versions 2.1.9.95 and prior).
Stack-based buffer overflow in Advantech WebAccess (formerly BroadWin WebAccess) 7.2 allows remote attackers to execute arbitrary code via the NodeName2 parameter.
Advantech WebAccess HMI Designer, Versions 2.1.9.31 and prior. A double free vulnerability caused by processing specially crafted project files may allow remote code execution, disclosure/modification of information, or cause the application to crash.
Advantech WebAccess HMI Designer, Versions 2.1.9.31 and prior. Processing specially crafted project files lacking proper validation of user supplied data may cause a type confusion condition, which may allow remote code execution, disclosure/modification of information, or cause the application to crash.
Advantech WebAccess HMI Designer, Versions 2.1.9.31 and prior. Multiple heap-based buffer overflow vulnerabilities may be exploited by opening specially crafted project files that may overflow the heap, which may allow remote code execution, disclosure/modification of information, or cause the application to crash.
Advantech WebAccess HMI Designer, Versions 2.1.9.31 and prior. Processing specially crafted project files lacking proper validation of user supplied data may cause the system to write outside the intended buffer area, which may allow remote code execution, disclosure/modification of information, or cause the application to crash.
Cscape, 9.80 SP4 and prior. An improper input validation vulnerability may be exploited by processing specially crafted POC files. This may allow an attacker to read confidential information and remotely execute arbitrary code.
A memory corruption vulnerability has been identified in WECON LeviStudioU version 1.8.56 and prior, which may allow arbitrary code execution. Mat Powell, Ziad Badawi, and Natnael Samson working with Trend Micro's Zero Day Initiative, reported these vulnerabilities to NCCIC.
Cross-site request forgery has been identified in Moxa IKS and EDS, which may allow for the execution of unauthorized actions on the device.
Multiple stack-based buffer overflow vulnerabilities in WECON LeviStudioU version 1.8.56 and prior may be exploited when parsing strings within project files. The process does not properly validate the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage these vulnerabilities to execute code under the context of the current process. Mat Powell, Ziad Badawi, and Natnael Samson working with Trend Micro's Zero Day Initiative, reported these vulnerabilities to NCCIC.
Double free vulnerabilities in Advantech WebAccess HMI Designer 2.1.7.32 and prior caused by processing specially crafted .pm3 files may allow remote code execution.
WPLSoft in Delta Electronics versions 2.45.0 and prior writes data from a file outside the bounds of the intended buffer space, which could cause memory corruption or may allow remote code execution.
CX-Supervisor (Versions 3.42 and prior) can execute code that has been injected into a project file. An attacker could exploit this to execute code under the privileges of the application.
In AutomationDirect CLICK Programming Software (Part Number C0-PGMSW) Versions 2.10 and prior; C-More Programming Software (Part Number EA9-PGMSW) Versions 6.30 and prior; C-More Micro (Part Number EA-PGMSW) Versions 4.20.01.0 and prior; Do-more Designer Software (Part Number DM-PGMSW) Versions 2.0.3 and prior; GS Drives Configuration Software (Part Number GSOFT) Versions 4.0.6 and prior; SL-SOFT SOLO Temperature Controller Configuration Software (Part Number SL-SOFT) Versions 1.1.0.5 and prior; and DirectSOFT Programming Software Versions 6.1 and prior, an uncontrolled search path element (DLL Hijacking) vulnerability has been identified. To exploit this vulnerability, an attacker could rename a malicious DLL to meet the criteria of the application, and the application would not verify that the DLL is correct. Once loaded by the application, the DLL could run malicious code at the privilege level of the application.
PC-Doctor Toolbox before 7.3 has an Uncontrolled Search Path Element.
An Uncontrolled Search Path or Element issue was discovered in i-SENS SmartLog Diabetes Management Software, Version 2.4.0 and prior versions. An uncontrolled search path element vulnerability has been identified which could be exploited by placing a specially crafted DLL file in the search path. If the malicious DLL is loaded prior to the valid DLL, an attacker could execute arbitrary code on the system. This vulnerability does not affect the connected blood glucose monitor and would not impact delivery of therapy to the patient.
Privilege escalation due to insecure directory permissions affecting ViveportDesktopService in HTC VIVEPORT before 1.0.0.36 allows local attackers to escalate privileges via DLL hijacking.
In the F-Secure installer in F-Secure SAFE for Windows before 17.6, F-Secure Internet Security before 17.6, F-Secure Anti-Virus before 17.6, F-Secure Client Security Standard and Premium before 14.10, F-Secure PSB Workstation Security before 12.01, and F-Secure Computer Protection Standard and Premium before 19.3, a local user can escalate their privileges through a DLL hijacking attack against the installer. The installer writes the file rm.exe to C:\Windows\Temp and then executes it. The rm.exe process then attempts to load several DLLs from its current directory. Non-admin users are able to write to this folder, so an attacker can create a malicious C:\Windows\Temp\OLEACC.dll file. When an admin runs the installer, rm.exe will execute the attacker's DLL in an elevated security context.
Akeo Consulting Rufus 3.0 and earlier is affected by: DLL search order hijacking. The impact is: Arbitrary code execution WITH escalation of privilege. The component is: Executable installers, portable executables (ALL executables on the web site). The attack vector is: CAPEC-471, CWE-426, CWE-427.
Quick Heal Total Security 64 bit 17.00 (QHTS64.exe), (QHTSFT64.exe) - Version 10.0.1.38; Quick Heal Total Security 32 bit 17.00 (QHTS32.exe), (QHTSFT32.exe) - Version 10.0.1.38; Quick Heal Internet Security 64 bit 17.00 (QHIS64.exe), (QHISFT64.exe) - Version 10.0.0.37; Quick Heal Internet Security 32 bit 17.00 (QHIS32.exe), (QHISFT32.exe) - Version 10.0.0.37; Quick Heal AntiVirus Pro 64 bit 17.00 (QHAV64.exe), (QHAVFT64.exe) - Version 10.0.0.37; and Quick Heal AntiVirus Pro 32 bit 17.00 (QHAV32.exe), (QHAVFT32.exe) - Version 10.0.0.37 allow DLL Hijacking because of Insecure Library Loading.
A DLL hijacking vulnerability exists in Schneider Electric Software Update (SESU), all versions prior to V2.2.0, which could allow an attacker to execute arbitrary code on the targeted system when placing a specific DLL file.
Norton Power Eraser (prior to 5.3.0.24) and SymDiag (prior to 2.1.242) may be susceptible to a DLL Preloading vulnerability, which is a type of issue that can occur when an application looks to call a DLL for execution and an attacker provides a malicious DLL to use instead. Depending on how the application is configured, it will generally follow a specific search path to locate the DLL. The vulnerability can be exploited by a simple file write (or potentially an over-write) which results in a foreign DLL running under the context of the application.
ExifTool 8.32 allows local users to gain privileges by creating a %TEMP%\par-%username%\cache-exiftool-8.32 folder with a victim's username, and then copying a Trojan horse ws32_32.dll file into this new folder, aka DLL Hijacking. NOTE: 8.32 is an obsolete version from 2010 (9.x was released starting in 2012, and 10.x was released starting in 2015).