Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2017-7973

Summary
Assigner-schneider
Assigner Org ID-076d1eb6-cfab-4401-b34d-6dfc2a413bdb
Published At-25 Sep, 2017 | 19:00
Updated At-16 Sep, 2024 | 16:13
Rejected At-
Credits

A SQL injection vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which an unauthenticated user can use calls to various paths allowing performance of arbitrary SQL commands against the underlying database.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:schneider
Assigner Org ID:076d1eb6-cfab-4401-b34d-6dfc2a413bdb
Published At:25 Sep, 2017 | 19:00
Updated At:16 Sep, 2024 | 16:13
Rejected At:
▼CVE Numbering Authority (CNA)

A SQL injection vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which an unauthenticated user can use calls to various paths allowing performance of arbitrary SQL commands against the underlying database.

Affected Products
Vendor
Schneider Electric SESchneider Electric SE
Product
U.Motion
Versions
Affected
  • U.motion Builder Versions 1.2.1 and prior.
Problem Types
TypeCWE IDDescription
textN/ASQL Injection
Type: text
CWE ID: N/A
Description: SQL Injection
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
http://www.schneider-electric.com/en/download/document/SEVD-2017-178-01/
x_refsource_CONFIRM
http://www.securityfocus.com/bid/99344
vdb-entry
x_refsource_BID
Hyperlink: http://www.schneider-electric.com/en/download/document/SEVD-2017-178-01/
Resource:
x_refsource_CONFIRM
Hyperlink: http://www.securityfocus.com/bid/99344
Resource:
vdb-entry
x_refsource_BID
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
http://www.schneider-electric.com/en/download/document/SEVD-2017-178-01/
x_refsource_CONFIRM
x_transferred
http://www.securityfocus.com/bid/99344
vdb-entry
x_refsource_BID
x_transferred
Hyperlink: http://www.schneider-electric.com/en/download/document/SEVD-2017-178-01/
Resource:
x_refsource_CONFIRM
x_transferred
Hyperlink: http://www.securityfocus.com/bid/99344
Resource:
vdb-entry
x_refsource_BID
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cybersecurity@se.com
Published At:26 Sep, 2017 | 01:29
Updated At:20 Apr, 2025 | 01:37

A SQL injection vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which an unauthenticated user can use calls to various paths allowing performance of arbitrary SQL commands against the underlying database.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.09.8CRITICAL
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Primary2.07.5HIGH
AV:N/AC:L/Au:N/C:P/I:P/A:P
Type: Primary
Version: 3.0
Base score: 9.8
Base severity: CRITICAL
Vector:
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 2.0
Base score: 7.5
Base severity: HIGH
Vector:
AV:N/AC:L/Au:N/C:P/I:P/A:P
CPE Matches

Schneider Electric SE
schneider-electric
>>u.motion_builder>>Versions up to 1.2.1(inclusive)
cpe:2.3:a:schneider-electric:u.motion_builder:*:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-89Primarynvd@nist.gov
CWE ID: CWE-89
Type: Primary
Source: nvd@nist.gov
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
http://www.schneider-electric.com/en/download/document/SEVD-2017-178-01/cybersecurity@se.com
Vendor Advisory
http://www.securityfocus.com/bid/99344cybersecurity@se.com
Third Party Advisory
VDB Entry
http://www.schneider-electric.com/en/download/document/SEVD-2017-178-01/af854a3a-2127-422b-91ae-364da2661108
Vendor Advisory
http://www.securityfocus.com/bid/99344af854a3a-2127-422b-91ae-364da2661108
Third Party Advisory
VDB Entry
Hyperlink: http://www.schneider-electric.com/en/download/document/SEVD-2017-178-01/
Source: cybersecurity@se.com
Resource:
Vendor Advisory
Hyperlink: http://www.securityfocus.com/bid/99344
Source: cybersecurity@se.com
Resource:
Third Party Advisory
VDB Entry
Hyperlink: http://www.schneider-electric.com/en/download/document/SEVD-2017-178-01/
Source: af854a3a-2127-422b-91ae-364da2661108
Resource:
Vendor Advisory
Hyperlink: http://www.securityfocus.com/bid/99344
Source: af854a3a-2127-422b-91ae-364da2661108
Resource:
Third Party Advisory
VDB Entry

Change History

0
Information is not available yet

Similar CVEs

6829Records found

CVE-2016-5815
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-1.19% / 77.95%
||
7 Day CHG~0.00%
Published-13 Feb, 2017 | 21:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered on Schneider Electric IONXXXX series power meters ION73XX series, ION75XX series, ION76XX series, ION8650 series, ION8800 series, and PM5XXX series. No authentication is configured by default. An unauthorized user can access the device management portal and make configuration changes.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-ion7300ion7600ion7500ion5000ion8650ion8800Schneider Electric IONXXXX Series Power Meter Vulnerabilities
CWE ID-CWE-284
Improper Access Control
CVE-2016-4529
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.3||HIGH
EPSS-2.86% / 85.73%
||
7 Day CHG~0.00%
Published-15 Jul, 2016 | 16:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An unspecified ActiveX control in Schneider Electric SoMachine HVAC Programming Software for M171/M172 Controllers before 2.1.0 allows remote attackers to execute arbitrary code via unknown vectors, related to the INTERFACESAFE_FOR_UNTRUSTED_CALLER (aka safe for scripting) flag.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-somachine_hvac_firmwarem171m172n/a
CVE-2016-4520
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-2.71% / 85.36%
||
7 Day CHG~0.00%
Published-15 Jul, 2016 | 16:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Schneider Electric Pelco Digital Sentry Video Management System with firmware before 7.14 has hardcoded credentials, which allows remote attackers to obtain access, and consequently execute arbitrary code, via unspecified vectors.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-pelco_digital_sentry_video_management_system_firmwaren/a
CVE-2020-7498
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.49% / 64.40%
||
7 Day CHG~0.00%
Published-16 Jun, 2020 | 19:15
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-798: Use of Hard-coded Credentials vulnerability exists in the Unity Loader and OS Loader Software (all versions). The fixed credentials are used to simplify file transfer. Today the use of fixed credentials is considered a vulnerability, which could cause unauthorized access to the file transfer service provided by the Modicon PLCs. This could result in various unintended results.

Action-Not Available
Vendor-n/a
Product-os_loaderunity_loaderUnity Loader and OS Loader Software (All versions)
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2020-7497
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.49% / 80.27%
||
7 Day CHG~0.00%
Published-16 Jun, 2020 | 19:13
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)which could cause arbitrary application execution when the computer starts.

Action-Not Available
Vendor-n/a
Product-ecostruxure_operator_terminal_expertEcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2021-22731
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-2.01% / 82.95%
||
7 Day CHG~0.00%
Published-26 May, 2021 | 19:19
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Weak Password Recovery Mechanism for Forgotten Password vulnerability exists on Modicon Managed Switch MCSESM* and MCSESP* V8.21 and prior which could cause an unauthorized password change through HTTP / HTTPS when basic user information is known by a remote attacker.

Action-Not Available
Vendor-n/a
Product-mcsesm083f23f0hmcsesp083f23g0t_firmwaremcsesm083f23f0_firmwaremcsesp083f23g0tmcsesm063f2cu0mcsesm063f2cs0_firmwaremcsesm103f2cu0mcsesm123f2lg0mcsesp083f23g0_firmwaremcsesm103f2cu0hmcsesm053f1cu0_firmwaremcsesm103f2cs0hmcsesm093f1cu0_firmwaremcsesm093f1cu0mcsesm043f23f0_firmwaremcsesm093f1cs0_firmwaremcsesm053f1cu0mcsesm043f23f0mcsesm103f2cs0_firmwaremcsesm103f2cs0h_firmwaremcsesm083f23f0h_firmwaremcsesm083f23f0mcsesm063f2cu0_firmwaremcsesm123f2lg0_firmwaremcsesm053f1cs0_firmwaremcsesp083f23g0mcsesm063f2cs0mcsesm103f2cu0_firmwaremcsesm103f2cu0h_firmwaremcsesm093f1cs0mcsesm103f2cs0mcsesm053f1cs0Modicon Managed Switch MCSESM* and MCSESP* V8.21 and prior
CWE ID-CWE-640
Weak Password Recovery Mechanism for Forgotten Password
CVE-2017-5155
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.3||HIGH
EPSS-0.64% / 69.66%
||
7 Day CHG~0.00%
Published-13 Feb, 2017 | 21:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in Schneider Electric Wonderware Historian 2014 R2 SP1 P01 and earlier. Wonderware Historian creates logins with default passwords, which can allow a malicious entity to compromise Historian databases. In some installation scenarios, resources beyond those created by Wonderware Historian may be compromised as well.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-wonderware_historianSchneider Electric Wonderware Historian 2014 R2 SP1 P01 and earlier
CWE ID-CWE-1188
Initialization of a Resource with an Insecure Default
CVE-2018-7241
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.58% / 67.96%
||
7 Day CHG~0.00%
Published-18 Apr, 2018 | 20:00
Updated-05 Aug, 2024 | 06:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Hard coded accounts exist in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules.

Action-Not Available
Vendor-
Product-140cpu65160ctsxp573634mmodicon_m340_bmxp3420302h_firmware140cpu65160_firmwaretsxh5744m_firmwaremodicon_m340_bmxp342020h_firmwaretsxh5744m140cpu65160s_firmwaretsxp571634mcmodicon_m340_bmxp3420102cltsxp574634m_firmwaremodicon_m340_bmxp3420302_firmwaretsxp575634mtsxh5724mc_firmwaretsxp57304mc140cpu65860tsxp575634mc140cpu65160modicon_m340_bmxp3420302cl_firmwaretsxh5744mc_firmwaretsxp573634mc_firmwaremodicon_m340_bmxp342020_firmwaretsxp57454m_firmwaretsxp57254m_firmwaremodicon_m340_bmxp3420102_firmwaretsxp572634mtsxp57554mc_firmwaretsxp574634mtsxh5724mtsxp57304m_firmwaretsxp571634mc_firmwaretsxp57454mcmodicon_m340_bmxp341000h140cpu65160sbmxnor0200_firmwaremodicon_m340_bmxp3420302clbmxnor0200htsxp574634mc_firmwaretsxp57154mctsxp57154m_firmwaretsxp57154mtsxp576634mtsxh5744mctsxp57204mcmodicon_m340_bmxp342020140cpu31110modicon_m340_bmxp342020htsxp57354mc_firmwaretsxp57104m140cpu65150c_firmwaretsxp57354m140cpu65150_firmwaremodicon_m340_bmxp342000_firmware140cpu65860cbmxnor0200h_firmwaretsxp57204m_firmwaretsxp57204m140cpu65260tsxp571634m_firmwaretsxp573634mc140cpu43412uc140cpu65150tsxp571634mtsxp57304mc_firmware140cpu65860_firmwarebmxnor0200modicon_m340_bmxp341000h_firmware140cpu65260ctsxp57354mc140cpu65150c140cpu43412u_firmwaretsxh5724m_firmwaremodicon_m340_bmxp342000tsxp575634m_firmwaretsxp573634m_firmwaretsxp57204mc_firmwaretsxp57104mc_firmwaremodicon_m340_bmxp341000tsxh5724mc140cpu65260c_firmwaretsxp57254mc_firmware140cpu31110_firmware140cpu31110ctsxp57304mtsxp576634mcmodicon_m340_bmxp3420302htsxp574634mcmodicon_m340_bmxp3420102cl_firmwaretsxp572634mc_firmwaretsxp57454mc_firmwaretsxp576634mc_firmwaretsxp57554mctsxp575634mc_firmware140cpu65160c_firmwaretsxp576634m_firmware140cpu65260_firmwaremodicon_m340_bmxp3420302140cpu43412uc_firmwaretsxp57454mtsxp572634mcmodicon_m340_bmxp341000_firmwaretsxp57254mtsxp57104m_firmwaretsxp572634m_firmwaretsxp57554mtsxp57254mctsxp57354m_firmwaretsxp57104mctsxp57554m_firmwaremodicon_m340_bmxp3420102140cpu31110c_firmware140cpu43412utsxp57154mc_firmware140cpu65860c_firmwareModicon Premium, Modicon Quantum, Modicon M340, BMXNOR0200
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2018-7231
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.20% / 78.10%
||
7 Day CHG~0.00%
Published-09 Mar, 2018 | 23:00
Updated-16 Sep, 2024 | 19:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'system.opkg.remove'.

Action-Not Available
Vendor-
Product-imp519-1er_firmwareibp319-1erimp319-1erimps110-1eibp519-1er_firmwareimp1110-1er_firmwareimps110-1eribp1110-1erimp519-1_firmwareimp519-1ibps110-1er_firmwareimp219-1_firmwareimp319-1_firmwareimps110-1er_firmwareimp219-1erimp319-1mps110-1ibp319-1er_firmwareimp319-1er_firmwareimps110-1e_firmwareimp219-1e_firmwareimp219-1eibp219-1erimp1110-1e_firmwareimp1110-1_firmwareimp519-1eimp319-1e_firmwareimp1110-1erimp219-1ibp219-1er_firmwareimp519-1erimp1110-1eimp319-1eibp1110-1er_firmwareibps110-1erimp219-1er_firmwareimp519-1e_firmwareimp1110-1ibp519-1ermps110-1_firmwarePelco Sarix Professional
CWE ID-CWE-20
Improper Input Validation
CVE-2018-7246
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.16% / 37.31%
||
7 Day CHG~0.00%
Published-18 Apr, 2018 | 20:00
Updated-05 Aug, 2024 | 06:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A cleartext transmission of sensitive information vulnerability exists in Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS. he integrated web server (Port 80/443/TCP) of the affected devices could allow remote attackers to discover an administrative account. If default on device, it is not using a SSL in settings and if multiple request of the page "Access Control" (IP-address device/ups/pas_cont.htm) account data will be sent in cleartext

Action-Not Available
Vendor-
Product-mge_galaxy_4000mge_galaxy_5000mge_eps_8000mge_galaxy_pwmge_galaxy_300066074_mge_network_management_card_transversemge_comet_upsmge_eps_6000mge_galaxy_6000mge_galaxy_9000mge_eps_700066074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS
CWE ID-CWE-319
Cleartext Transmission of Sensitive Information
CVE-2018-7760
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.15% / 36.17%
||
7 Day CHG~0.00%
Published-18 Apr, 2018 | 20:00
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An authorization bypass vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. Requests to CGI functions allow malicious users to bypass authorization.

Action-Not Available
Vendor-
Product-140cpu65160ctsxp573634mmodicon_m340_bmxp3420302h_firmware140cpu65160_firmwaretsxh5744m_firmwaremodicon_m340_bmxp342020h_firmwaretsxh5744m140cpu65160s_firmwaretsxp571634mcmodicon_m340_bmxp3420102cltsxp574634m_firmwaremodicon_m340_bmxp3420302_firmwaretsxp575634mtsxh5724mc_firmwaretsxp57304mc140cpu65860tsxp575634mc140cpu65160modicon_m340_bmxp3420302cl_firmwaretsxh5744mc_firmwaretsxp573634mc_firmwaremodicon_m340_bmxp342020_firmwaretsxp57454m_firmwaretsxp57254m_firmwaremodicon_m340_bmxp3420102_firmwaretsxp572634mtsxp57554mc_firmwaretsxp574634mtsxh5724mtsxp57304m_firmwaretsxp571634mc_firmwaretsxp57454mcmodicon_m340_bmxp341000h140cpu65160sbmxnor0200_firmwaremodicon_m340_bmxp3420302clbmxnor0200htsxp574634mc_firmwaretsxp57154mctsxp57154m_firmwaretsxp57154mtsxp576634mtsxh5744mctsxp57204mcmodicon_m340_bmxp342020140cpu31110modicon_m340_bmxp342020htsxp57354mc_firmwaretsxp57104m140cpu65150c_firmwaretsxp57354m140cpu65150_firmwaremodicon_m340_bmxp342000_firmware140cpu65860cbmxnor0200h_firmwaretsxp57204m_firmwaretsxp57204m140cpu65260tsxp571634m_firmwaretsxp573634mc140cpu43412uc140cpu65150tsxp571634mtsxp57304mc_firmware140cpu65860_firmwarebmxnor0200modicon_m340_bmxp341000h_firmware140cpu65260ctsxp57354mc140cpu65150c140cpu43412u_firmwaretsxh5724m_firmwaremodicon_m340_bmxp342000tsxp575634m_firmwaretsxp573634m_firmwaretsxp57204mc_firmwaretsxp57104mc_firmwaremodicon_m340_bmxp341000tsxh5724mc140cpu65260c_firmwaretsxp57254mc_firmware140cpu31110_firmware140cpu31110ctsxp57304mtsxp576634mcmodicon_m340_bmxp3420302htsxp574634mcmodicon_m340_bmxp3420102cl_firmwaretsxp572634mc_firmwaretsxp57454mc_firmwaretsxp576634mc_firmwaretsxp57554mctsxp575634mc_firmware140cpu65160c_firmwaretsxp576634m_firmware140cpu65260_firmwaremodicon_m340_bmxp3420302140cpu43412uc_firmwaretsxp57454mtsxp572634mcmodicon_m340_bmxp341000_firmwaretsxp57254mtsxp57104m_firmwaretsxp572634m_firmwaretsxp57554mtsxp57254mctsxp57354m_firmwaretsxp57104mctsxp57554m_firmwaremodicon_m340_bmxp3420102140cpu31110c_firmware140cpu43412utsxp57154mc_firmware140cpu65860c_firmwareModicon M340, Modicon Premium, Modicon Quantum, BMXNOR0201
CWE ID-CWE-287
Improper Authentication
CVE-2018-7780
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.54% / 66.74%
||
7 Day CHG~0.00%
Published-03 Jul, 2018 | 14:00
Updated-17 Sep, 2024 | 00:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, a buffer overflow vulnerability exist in cgi program "set".

Action-Not Available
Vendor-
Product-imp519-1er_firmwareimp319-1eribp319-1erimps110-1eibp519-1er_firmwareimp1110-1er_firmwareimps110-1eribp1110-1erimp519-1_firmwareimp519-1ibps110-1er_firmwareimp219-1_firmwareimp319-1_firmwareimps110-1er_firmwareimp219-1erimps110-1_firmwareibp319-1er_firmwareimp319-1er_firmwareimps110-1e_firmwareimp219-1e_firmwareimp219-1eibp219-1erimps110-1imp1110-1e_firmwareimp1110-1_firmwareimp519-1eimp319-1e_firmwareimp1110-1erimp219-1ibp219-1er_firmwareimp519-1erimp1110-1eimp319-1eibp1110-1er_firmwareibps110-1erimp219-1er_firmwareimp519-1e_firmwareimp1110-1ibp519-1erimp319-1Pelco Sarix Professional V1
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2018-7811
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.62% / 81.10%
||
7 Day CHG~0.00%
Published-30 Nov, 2018 | 19:00
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An Unverified Password Change vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 which could allow an unauthenticated remote user to access the change password function of the web server

Action-Not Available
Vendor-
Product-modicom_bmxnor0200hmodicom_quantum_firmwaremodicom_premiummodicom_bmxnor0200h_firmwaremodicom_m340_firmwaremodicom_m340modicom_quantummodicom_premium_firmwareEmbedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200
CWE ID-CWE-640
Weak Password Recovery Mechanism for Forgotten Password
CVE-2018-7233
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.20% / 78.10%
||
7 Day CHG~0.00%
Published-09 Mar, 2018 | 23:00
Updated-17 Sep, 2024 | 01:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'model_name' or 'mac_address'.

Action-Not Available
Vendor-
Product-imp519-1er_firmwareibp319-1erimp319-1erimps110-1eibp519-1er_firmwareimp1110-1er_firmwareimps110-1eribp1110-1erimp519-1_firmwareimp519-1ibps110-1er_firmwareimp219-1_firmwareimp319-1_firmwareimps110-1er_firmwareimp219-1erimp319-1mps110-1ibp319-1er_firmwareimp319-1er_firmwareimps110-1e_firmwareimp219-1e_firmwareimp219-1eibp219-1erimp1110-1e_firmwareimp1110-1_firmwareimp519-1eimp319-1e_firmwareimp1110-1erimp219-1ibp219-1er_firmwareimp519-1erimp1110-1eimp319-1eibp1110-1er_firmwareibps110-1erimp219-1er_firmwareimp519-1e_firmwareimp1110-1ibp519-1ermps110-1_firmwarePelco Sarix Professional
CWE ID-CWE-20
Improper Input Validation
CVE-2018-7228
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.73% / 71.79%
||
7 Day CHG~0.00%
Published-09 Mar, 2018 | 23:00
Updated-16 Sep, 2024 | 23:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to bypass authentication and get the administrator privileges.

Action-Not Available
Vendor-
Product-imp519-1er_firmwareibp319-1erimp319-1erimps110-1eibp519-1er_firmwareimp1110-1er_firmwareimps110-1eribp1110-1erimp519-1_firmwareimp519-1ibps110-1er_firmwareimp219-1_firmwareimp319-1_firmwareimps110-1er_firmwareimp219-1erimp319-1mps110-1ibp319-1er_firmwareimp319-1er_firmwareimps110-1e_firmwareimp219-1e_firmwareimp219-1eibp219-1erimp1110-1e_firmwareimp1110-1_firmwareimp519-1eimp319-1e_firmwareimp1110-1erimp219-1ibp219-1er_firmwareimp519-1erimp1110-1eimp319-1eibp1110-1er_firmwareibps110-1erimp219-1er_firmwareimp519-1e_firmwareimp1110-1ibp519-1ermps110-1_firmwarePelco Sarix Professional
CWE ID-CWE-287
Improper Authentication
CVE-2018-7791
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.34% / 55.66%
||
7 Day CHG~0.00%
Published-29 Aug, 2018 | 21:00
Updated-17 Sep, 2024 | 04:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Permissions, Privileges, and Access Control vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to overwrite the original password with their password. If an attacker exploits this vulnerability and overwrite the password, the attacker can upload the original program from the PLC.

Action-Not Available
Vendor-
Product-modicon_m221_firmwaremodicon_m221Modicon M221, all references, all versions prior to firmware V1.6.2.0
CWE ID-CWE-287
Improper Authentication
CVE-2018-7800
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.17% / 77.84%
||
7 Day CHG~0.00%
Published-24 Dec, 2018 | 16:00
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Hard-coded Credentials vulnerability exists in EVLink Parking, v3.2.0-12_v1 and earlier, which could enable an attacker to gain access to the device.

Action-Not Available
Vendor-
Product-evlink_parkingevlink_parking_firmwareEVLink Parking v3.2.0-12_v1 and earlier
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2018-7243
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-2.35% / 84.28%
||
7 Day CHG~0.00%
Published-18 Apr, 2018 | 20:00
Updated-05 Aug, 2024 | 06:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An authorization bypass vulnerability exists In Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS. The integrated web server (Port 80/443/TCP) of the affected devices could allow a remote attacker to get a full access to device, bypassing the authorization system.

Action-Not Available
Vendor-
Product-mge_galaxy_4000mge_galaxy_5000mge_eps_8000mge_galaxy_pwmge_galaxy_300066074_mge_network_management_card_transversemge_comet_upsmge_eps_6000mge_galaxy_6000mge_galaxy_9000mge_eps_700066074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS
CVE-2018-7847
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.22% / 78.29%
||
7 Day CHG~0.00%
Published-22 May, 2019 | 20:00
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service or potential code execution by overwriting configuration settings of the controller over Modbus.

Action-Not Available
Vendor-n/a
Product-modicon_quantummodicon_quantum_firmwaremodicon_m580_firmwaremodicon_premium_firmwaremodicon_premiummodicon_m340modicon_m340_firmwaremodicon_m580Modicon M580 Modicon M340 Modicon Quantum Modicon Premium
CWE ID-CWE-287
Improper Authentication
CVE-2018-7778
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.69% / 70.93%
||
7 Day CHG~0.00%
Published-03 Jul, 2018 | 14:00
Updated-17 Sep, 2024 | 01:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Schneider Electric Evlink Charging Station versions prior to v3.2.0-12_v1, the Web Interface has an issue that may allow a remote attacker to gain administrative privileges without properly authenticating remote users.

Action-Not Available
Vendor-
Product-evlink_charging_stationevlink_charging_station_firmwareEvlink Charging Station
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2018-7238
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-2.73% / 85.39%
||
7 Day CHG~0.00%
Published-09 Mar, 2018 | 23:00
Updated-16 Sep, 2024 | 16:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A buffer overflow vulnerability exist in the web-based GUI of Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to execute arbitrary code.

Action-Not Available
Vendor-
Product-imp519-1er_firmwareibp319-1erimp319-1erimps110-1eibp519-1er_firmwareimp1110-1er_firmwareimps110-1eribp1110-1erimp519-1_firmwareimp519-1ibps110-1er_firmwareimp219-1_firmwareimp319-1_firmwareimps110-1er_firmwareimp219-1erimp319-1mps110-1ibp319-1er_firmwareimp319-1er_firmwareimps110-1e_firmwareimp219-1e_firmwareimp219-1eibp219-1erimp1110-1e_firmwareimp1110-1_firmwareimp519-1eimp319-1e_firmwareimp1110-1erimp219-1ibp219-1er_firmwareimp519-1erimp1110-1eimp319-1eibp1110-1er_firmwareibps110-1erimp219-1er_firmwareimp519-1e_firmwareimp1110-1ibp519-1ermps110-1_firmwarePelco Sarix Professional
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2018-7836
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-2.32% / 84.16%
||
7 Day CHG~0.00%
Published-24 Dec, 2018 | 16:00
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An unrestricted Upload of File with Dangerous Type vulnerability exists on numerous methods of the IIoT Monitor 3.1.38 software that could allow upload and execution of malicious files.

Action-Not Available
Vendor-
Product-iiot_monitorIIoT Monitor 3.1.38
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CVE-2018-7229
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.54% / 66.58%
||
7 Day CHG~0.00%
Published-09 Mar, 2018 | 23:00
Updated-16 Sep, 2024 | 19:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to bypass authentication and gain administrator privileges because the use of hardcoded credentials.

Action-Not Available
Vendor-
Product-imp519-1er_firmwareibp319-1erimp319-1erimps110-1eibp519-1er_firmwareimp1110-1er_firmwareimps110-1eribp1110-1erimp519-1_firmwareimp519-1ibps110-1er_firmwareimp219-1_firmwareimp319-1_firmwareimps110-1er_firmwareimp219-1erimp319-1mps110-1ibp319-1er_firmwareimp319-1er_firmwareimps110-1e_firmwareimp219-1e_firmwareimp219-1eibp219-1erimp1110-1e_firmwareimp1110-1_firmwareimp519-1eimp319-1e_firmwareimp1110-1erimp219-1ibp219-1er_firmwareimp519-1erimp1110-1eimp319-1eibp1110-1er_firmwareibps110-1erimp219-1er_firmwareimp519-1e_firmwareimp1110-1ibp519-1ermps110-1_firmwarePelco Sarix Professional
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2018-7785
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-14.47% / 94.18%
||
7 Day CHG~0.00%
Published-03 Jul, 2018 | 14:00
Updated-16 Sep, 2024 | 18:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Schneider Electric U.motion Builder software versions prior to v1.3.4, a remote command injection allows authentication bypass.

Action-Not Available
Vendor-
Product-u.motion_builderU.motion Builder
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2018-7242
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.26% / 49.22%
||
7 Day CHG~0.00%
Published-18 Apr, 2018 | 20:00
Updated-05 Aug, 2024 | 06:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Vulnerable hash algorithms exists in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules. The algorithm used to encrypt the password is vulnerable to hash collision attacks.

Action-Not Available
Vendor-
Product-140cpu65160ctsxp573634mmodicon_m340_bmxp3420302h_firmware140cpu65160_firmwaretsxh5744m_firmwaremodicon_m340_bmxp342020h_firmwaretsxh5744m140cpu65160s_firmwaretsxp571634mcmodicon_m340_bmxp3420102cltsxp574634m_firmwaremodicon_m340_bmxp3420302_firmwaretsxp575634mtsxh5724mc_firmwaretsxp57304mc140cpu65860tsxp575634mc140cpu65160modicon_m340_bmxp3420302cl_firmwaretsxh5744mc_firmwaretsxp573634mc_firmwaremodicon_m340_bmxp342020_firmwaretsxp57454m_firmwaretsxp57254m_firmwaremodicon_m340_bmxp3420102_firmwaretsxp572634mtsxp57554mc_firmwaretsxp574634mtsxh5724mtsxp57304m_firmwaretsxp571634mc_firmwaretsxp57454mcmodicon_m340_bmxp341000h140cpu65160sbmxnor0200_firmwaremodicon_m340_bmxp3420302clbmxnor0200htsxp574634mc_firmwaretsxp57154mctsxp57154m_firmwaretsxp57154mtsxp576634mtsxh5744mctsxp57204mcmodicon_m340_bmxp342020140cpu31110modicon_m340_bmxp342020htsxp57354mc_firmwaretsxp57104m140cpu65150c_firmwaretsxp57354m140cpu65150_firmwaremodicon_m340_bmxp342000_firmware140cpu65860cbmxnor0200h_firmwaretsxp57204m_firmwaretsxp57204m140cpu65260tsxp571634m_firmwaretsxp573634mc140cpu43412uc140cpu65150tsxp571634mtsxp57304mc_firmware140cpu65860_firmwarebmxnor0200modicon_m340_bmxp341000h_firmware140cpu65260ctsxp57354mc140cpu65150c140cpu43412u_firmwaretsxh5724m_firmwaremodicon_m340_bmxp342000tsxp575634m_firmwaretsxp573634m_firmwaretsxp57204mc_firmwaretsxp57104mc_firmwaremodicon_m340_bmxp341000tsxh5724mc140cpu65260c_firmwaretsxp57254mc_firmware140cpu31110_firmware140cpu31110ctsxp57304mtsxp576634mcmodicon_m340_bmxp3420302htsxp574634mcmodicon_m340_bmxp3420102cl_firmwaretsxp572634mc_firmwaretsxp57454mc_firmwaretsxp576634mc_firmwaretsxp57554mctsxp575634mc_firmware140cpu65160c_firmwaretsxp576634m_firmware140cpu65260_firmwaremodicon_m340_bmxp3420302140cpu43412uc_firmwaretsxp57454mtsxp572634mcmodicon_m340_bmxp341000_firmwaretsxp57254mtsxp57104m_firmwaretsxp572634m_firmwaretsxp57554mtsxp57254mctsxp57354m_firmwaretsxp57104mctsxp57554m_firmwaremodicon_m340_bmxp3420102140cpu31110c_firmware140cpu43412utsxp57154mc_firmware140cpu65860c_firmwareModicon Premium, Modicon Quantum, Modicon M340, BMXNOR0200
CWE ID-CWE-326
Inadequate Encryption Strength
CVE-2018-7784
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.00% / 76.11%
||
7 Day CHG~0.00%
Published-03 Jul, 2018 | 14:00
Updated-16 Sep, 2024 | 19:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Schneider Electric U.motion Builder software versions prior to v1.3.4, this exploit occurs when the submitted data of an input string is evaluated as a command by the application. In this way, the attacker could execute code, read the stack, or cause a segmentation fault in the running application.

Action-Not Available
Vendor-
Product-u.motionU.motion Builder
CWE ID-CWE-20
Improper Input Validation
CVE-2018-7842
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-6.47% / 90.69%
||
7 Day CHG~0.00%
Published-22 May, 2019 | 19:59
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-290: Authentication Bypass by Spoofing vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause an elevation of privilege by conducting a brute force attack on Modbus parameters sent to the controller.

Action-Not Available
Vendor-n/a
Product-modicon_quantummodicon_quantum_firmwaremodicon_m580_firmwaremodicon_premium_firmwaremodicon_premiummodicon_m340modicon_m340_firmwaremodicon_m580Modicon M580 Modicon M340 Modicon Quantum Modicon Premium
CWE ID-CWE-290
Authentication Bypass by Spoofing
CVE-2018-7809
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.98% / 82.85%
||
7 Day CHG~0.00%
Published-30 Nov, 2018 | 19:00
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An Unverified Password Change vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 which could allow an unauthenticated remote user to access the password delete function of the web server.

Action-Not Available
Vendor-
Product-modicom_bmxnor0200hmodicom_quantum_firmwaremodicom_premiummodicom_bmxnor0200h_firmwaremodicom_m340_firmwaremodicom_m340modicom_quantummodicom_premium_firmwareEmbedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200
CWE ID-CWE-640
Weak Password Recovery Mechanism for Forgotten Password
CVE-2018-7232
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.20% / 78.10%
||
7 Day CHG~0.00%
Published-09 Mar, 2018 | 23:00
Updated-17 Sep, 2024 | 00:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'network.ieee8021x.delete_certs'.

Action-Not Available
Vendor-
Product-imp519-1er_firmwareibp319-1erimp319-1erimps110-1eibp519-1er_firmwareimp1110-1er_firmwareimps110-1eribp1110-1erimp519-1_firmwareimp519-1ibps110-1er_firmwareimp219-1_firmwareimp319-1_firmwareimps110-1er_firmwareimp219-1erimp319-1mps110-1ibp319-1er_firmwareimp319-1er_firmwareimps110-1e_firmwareimp219-1e_firmwareimp219-1eibp219-1erimp1110-1e_firmwareimp1110-1_firmwareimp519-1eimp319-1e_firmwareimp1110-1erimp219-1ibp219-1er_firmwareimp519-1erimp1110-1eimp319-1eibp1110-1er_firmwareibps110-1erimp219-1er_firmwareimp519-1e_firmwareimp1110-1ibp519-1ermps110-1_firmwarePelco Sarix Professional
CWE ID-CWE-20
Improper Input Validation
CVE-2018-7761
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.58% / 67.86%
||
7 Day CHG~0.00%
Published-18 Apr, 2018 | 20:00
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability exists in the HTTP request parser in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow arbitrary code execution.

Action-Not Available
Vendor-
Product-140cpu65160ctsxp573634mmodicon_m340_bmxp3420302h_firmware140cpu65160_firmwaretsxh5744m_firmwaremodicon_m340_bmxp342020h_firmwaretsxh5744m140cpu65160s_firmwaretsxp571634mcmodicon_m340_bmxp3420102cltsxp574634m_firmwaremodicon_m340_bmxp3420302_firmwaretsxp575634mtsxh5724mc_firmwaretsxp57304mc140cpu65860tsxp575634mc140cpu65160modicon_m340_bmxp3420302cl_firmwaretsxh5744mc_firmwaretsxp573634mc_firmwaremodicon_m340_bmxp342020_firmwaretsxp57454m_firmwaretsxp57254m_firmwaremodicon_m340_bmxp3420102_firmwaretsxp572634mtsxp57554mc_firmwaretsxp574634mtsxh5724mtsxp57304m_firmwaretsxp571634mc_firmwaretsxp57454mcmodicon_m340_bmxp341000h140cpu65160sbmxnor0200_firmwaremodicon_m340_bmxp3420302clbmxnor0200htsxp574634mc_firmwaretsxp57154mctsxp57154m_firmwaretsxp57154mtsxp576634mtsxh5744mctsxp57204mcmodicon_m340_bmxp342020140cpu31110modicon_m340_bmxp342020htsxp57354mc_firmwaretsxp57104m140cpu65150c_firmwaretsxp57354m140cpu65150_firmwaremodicon_m340_bmxp342000_firmware140cpu65860cbmxnor0200h_firmwaretsxp57204m_firmwaretsxp57204m140cpu65260tsxp571634m_firmwaretsxp573634mc140cpu43412uc140cpu65150tsxp571634mtsxp57304mc_firmware140cpu65860_firmwarebmxnor0200modicon_m340_bmxp341000h_firmware140cpu65260ctsxp57354mc140cpu65150c140cpu43412u_firmwaretsxh5724m_firmwaremodicon_m340_bmxp342000tsxp575634m_firmwaretsxp573634m_firmwaretsxp57204mc_firmwaretsxp57104mc_firmwaremodicon_m340_bmxp341000tsxh5724mc140cpu65260c_firmwaretsxp57254mc_firmware140cpu31110_firmware140cpu31110ctsxp57304mtsxp576634mcmodicon_m340_bmxp3420302htsxp574634mcmodicon_m340_bmxp3420102cl_firmwaretsxp572634mc_firmwaretsxp57454mc_firmwaretsxp576634mc_firmwaretsxp57554mctsxp575634mc_firmware140cpu65160c_firmwaretsxp576634m_firmware140cpu65260_firmwaremodicon_m340_bmxp3420302140cpu43412uc_firmwaretsxp57454mtsxp572634mcmodicon_m340_bmxp341000_firmwaretsxp57254mtsxp57104m_firmwaretsxp572634m_firmwaretsxp57554mtsxp57254mctsxp57354m_firmwaretsxp57104mctsxp57554m_firmwaremodicon_m340_bmxp3420102140cpu31110c_firmware140cpu43412utsxp57154mc_firmware140cpu65860c_firmwareModicon M340, Modicon Premium, Modicon Quantum, BMXNOR0202
CWE ID-CWE-20
Improper Input Validation
CVE-2015-0982
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.5||HIGH
EPSS-2.56% / 84.93%
||
7 Day CHG~0.00%
Published-14 Mar, 2015 | 01:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Buffer overflow in an unspecified DLL in Schneider Electric Pelco DS-NVs before 7.8.90 allows remote attackers to execute arbitrary code via unspecified vectors.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-pelco_ds-nvn/a
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2014-9200
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.5||HIGH
EPSS-1.47% / 80.13%
||
7 Day CHG~0.00%
Published-01 Feb, 2015 | 15:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Stack-based buffer overflow in an unspecified DLL file in a DTM development kit in Schneider Electric Unity Pro, SoMachine, SoMove, SoMove Lite, Modbus Communication Library 2.2.6 and earlier, CANopen Communication Library 1.0.2 and earlier, EtherNet/IP Communication Library 1.0.0 and earlier, EM X80 Gateway DTM (MB TCP/SL), Advantys DTM for OTB, Advantys DTM for STB, KINOS DTM, SOLO DTM, and Xantrex DTMs allows remote attackers to execute arbitrary code via unspecified vectors.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-unity_prosomovesomove_litesomachinen/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2018-7790
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.49% / 64.64%
||
7 Day CHG~0.00%
Published-29 Aug, 2018 | 21:00
Updated-16 Sep, 2024 | 19:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An Information Management Error vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to replay authentication sequences. If an attacker exploits this vulnerability and connects to a Modicon M221, the attacker can upload the original program from the PLC.

Action-Not Available
Vendor-
Product-modicon_m221_firmwaremodicon_m221Modicon M221, all references, all versions prior to firmware V1.6.2.0
CWE ID-CWE-294
Authentication Bypass by Capture-replay
CVE-2020-7475
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.57% / 67.66%
||
7 Day CHG~0.00%
Published-23 Mar, 2020 | 18:56
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection'), reflective DLL, vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior to V3.10), which, if exploited, could allow attackers to transfer malicious code to the controller.

Action-Not Available
Vendor-n/a
Product-ecostruxure_control_expertmodicon_m580_firmwareunity_promodicon_m340modicon_m340_firmwaremodicon_m580EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior to V3.10)
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CVE-2020-7521
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.73% / 71.83%
||
7 Day CHG~0.00%
Published-31 Aug, 2020 | 16:10
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in SFAPV9601 - APC Easy UPS On-Line Software (V2.0 and earlier) when accessing a vulnerable method of `FileUploadServlet` which may lead to uploading executable files to non-specified directories.

Action-Not Available
Vendor-n/a
Product-apc_easy_ups_online_softwareSFAPV9601 - APC Easy UPS On-Line Software V2.0 and earlier
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2020-7540
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.31% / 53.68%
||
7 Day CHG~0.00%
Published-11 Dec, 2020 | 00:52
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause unauthenticated command execution in the controller when sending special HTTP requests.

Action-Not Available
Vendor-n/a
Product-140noc78100140cpu65150140noc78000_firmwaretsxp575634_firmware140noc78000bmxnoe0110_firmware140cpu65160_firmwaretsxp574634modicon_m340_bmxp3420102clmodicon_m340_bmxp3420302_firmwarebmxnor200h_firmware140noc78100_firmwaremodicon_m340_bmxp342000140cpu65160modicon_m340_bmxp3420302cl_firmwaremodicon_m340_bmxp341000140noe77111_firmwaremodicon_m340_bmxp342020_firmware140noc77101_firmwaremodicon_m340_bmxp3420102_firmware140noc77101bmxnoe0110140noe77101tsxety5103_firmwaremodicon_m340_bmxp3420102cl_firmwaretsxety5103tsxp574634_firmwarebmxnoc0401_firmware140noe77111modicon_m340_bmxp3420302clmodicon_m340_bmxp3420302140noe77101_firmwaremodicon_m340_bmxp342020bmxnoe0100_firmwaretsxp576634modicon_m340_bmxp341000_firmwaretsxety4103_firmwarebmxnor200htsxp576634_firmwarebmxnoc0401modicon_m340_bmxp342000_firmwarebmxnoe0100140cpu65150_firmwaremodicon_m340_bmxp3420102tsxety4103tsxp575634Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions)
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2020-7533
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.24% / 46.22%
||
7 Day CHG~0.00%
Published-01 Dec, 2020 | 14:47
Updated-10 Jun, 2025 | 08:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-287: Improper Authentication vulnerability exists which could cause the execution of commands on the webserver without authentication when sending specially crafted HTTP requests.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-140noc78000tsxp574634_firmwaretsxp574634140cpu65260_firmwaretsxety4103tsxp575634modicon_m340_bmxp342000modicon_m340_bmxp3420302_firmwarebmxnoe0100modicon_m340_bmxp342000_firmwarebmxnoe0110_firmwaretsxety5103_firmwaretsxp576634140noe77111_firmwaremodicon_m340_bmxp341000modicon_m340_bmxp3420102_firmwaremodicon_m340_bmxp341000_firmwarebmxnoe0110tsxp575634_firmware140noe77111bmxnoe0100_firmwarebmxnoc0401_firmware140noc77101140cpu65260bmxnoc0401140noc77101_firmwaretsxety4103_firmwaremodicon_m340_bmxp3420302140noc78000_firmwaretsxp576634_firmwaremodicon_m340_bmxp3420102tsxety5103Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules (see security notification for version information)
CWE ID-CWE-287
Improper Authentication
CVE-2020-7493
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.34% / 56.10%
||
7 Day CHG~0.00%
Published-16 Jun, 2020 | 19:10
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD) which could cause malicious code execution when opening the project file.

Action-Not Available
Vendor-n/a
Product-ecostruxure_operator_terminal_expertEcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2018-7765
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.23% / 45.85%
||
7 Day CHG~0.00%
Published-03 Jul, 2018 | 14:00
Updated-17 Sep, 2024 | 00:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The vulnerability exists within processing of track_import_export.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query is subject to SQL injection on the object_id input parameter.

Action-Not Available
Vendor-
Product-u.motion_builderU.Motion
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2023-37196
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.33% / 55.27%
||
7 Day CHG~0.00%
Published-12 Jul, 2023 | 06:22
Updated-07 Nov, 2024 | 14:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-89: Improper Neutralization of Special Elements vulnerability used in an SQL Command ('SQL Injection') vulnerability exists that could allow a user already authenticated on DCE to access unauthorized content, change, or delete content, or perform unauthorized actions when tampering with the alert settings of endpoints on DCE.

Action-Not Available
Vendor-
Product-struxureware_data_center_expertStruxureWare Data Center Expert struxureware_data_center_expert
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2023-37197
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.33% / 55.27%
||
7 Day CHG~0.00%
Published-12 Jul, 2023 | 06:41
Updated-07 Nov, 2024 | 14:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-89: Improper Neutralization of Special Elements vulnerability used in an SQL Command ('SQL Injection') vulnerability exists that could allow a user already authenticated on DCE to access unauthorized content, change, or delete content, or perform unauthorized actions when tampering with the mass configuration settings of endpoints on DCE.

Action-Not Available
Vendor-
Product-struxureware_data_center_expertStruxureWare Data Center Expert struxureware_data_center_expert
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2022-41671
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-7||HIGH
EPSS-0.07% / 20.87%
||
7 Day CHG~0.00%
Published-04 Nov, 2022 | 00:00
Updated-01 May, 2025 | 19:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-89: Improper Neutralization of Special Elements used in SQL Command (‘SQL Injection’) vulnerability exists that allows adversaries with local user privileges to craft a malicious SQL query and execute as part of project migration which could result in execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or prior).

Action-Not Available
Vendor-Schneider Electric SE
Product-ecostruxure_operator_terminal_expertpro-face_blueEcoStruxure Operator Terminal ExpertPro-face BLUE
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2018-7772
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.35% / 56.42%
||
7 Day CHG~0.00%
Published-03 Jul, 2018 | 14:00
Updated-16 Sep, 2024 | 23:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The vulnerability exists within processing of applets which are exposed on the web service in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query to determine whether a user is logged in is subject to SQL injection on the loginSeed parameter, which can be embedded in the HTTP cookie of the request.

Action-Not Available
Vendor-
Product-u.motion_builderU.Motion
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2018-7768
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.35% / 56.42%
||
7 Day CHG~0.00%
Published-03 Jul, 2018 | 14:00
Updated-16 Sep, 2024 | 23:01
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The vulnerability exists within processing of loadtemplate.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query is subject to SQL injection on the tpl input parameter.

Action-Not Available
Vendor-
Product-u.motion_builderU.Motion
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2018-7774
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.35% / 56.42%
||
7 Day CHG~0.00%
Published-03 Jul, 2018 | 14:00
Updated-16 Sep, 2024 | 23:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The vulnerability exists within processing of localize.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query is subject to SQL injection on the username input parameter.

Action-Not Available
Vendor-
Product-u.motion_builderU.Motion
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2018-7767
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.35% / 56.42%
||
7 Day CHG~0.00%
Published-03 Jul, 2018 | 14:00
Updated-17 Sep, 2024 | 02:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The vulnerability exists within processing of editobject.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query is subject to SQL injection on the type input parameter.

Action-Not Available
Vendor-
Product-u.motion_builderU.Motion
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2018-7773
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.35% / 56.42%
||
7 Day CHG~0.00%
Published-03 Jul, 2018 | 14:00
Updated-16 Sep, 2024 | 17:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The vulnerability exists within processing of nfcserver.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query is subject to SQL injection on the sessionid input parameter.

Action-Not Available
Vendor-
Product-u.motion_builderU.Motion
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2018-7766
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.35% / 56.42%
||
7 Day CHG~0.00%
Published-03 Jul, 2018 | 14:00
Updated-16 Sep, 2024 | 18:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The vulnerability exists within processing of track_getdata.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query is subject to SQL injection on the id input parameter.

Action-Not Available
Vendor-
Product-u.motion_builderU.Motion
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2018-7769
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.35% / 56.42%
||
7 Day CHG~0.00%
Published-03 Jul, 2018 | 14:00
Updated-16 Sep, 2024 | 17:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The vulnerability exists within processing of xmlserver.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query is subject to SQL injection on the id input parameter.

Action-Not Available
Vendor-
Product-u.motion_builderU.Motion
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2018-7802
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.87% / 74.26%
||
7 Day CHG~0.00%
Published-24 Dec, 2018 | 16:00
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A SQL Injection vulnerability exists in EVLink Parking, v3.2.0-12_v1 and earlier, which could give access to the web interface with full privileges.

Action-Not Available
Vendor-
Product-evlink_parkingevlink_parking_firmwareEVLink Parking v3.2.0-12_v1 and earlier
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')