In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, authenticated users can view passwords in clear text.
In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, by sending a specially crafted request an authenticated user can view password in clear text and results in privilege escalation.
Vulnerability in the Java SE, Java SE Embedded, JRockit component of Oracle Java SE (subcomponent: LDAP). Supported versions that are affected are Java SE: 6u171, 7u161, 8u152 and 9.0.1; Java SE Embedded: 8u151; JRockit: R28.3.16. Easily exploitable vulnerability allows low privileged attacker with network access via multiple protocols to compromise Java SE, Java SE Embedded, JRockit. Successful attacks of this vulnerability can result in unauthorized read access to a subset of Java SE, Java SE Embedded, JRockit accessible data. Note: This vulnerability applies to client and server deployment of Java. This vulnerability can be exploited through sandboxed Java Web Start applications and sandboxed Java applets. It can also be exploited by supplying data to APIs in the specified Component without using sandboxed Java Web Start applications or sandboxed Java applets, such as through a web service. CVSS 3.0 Base Score 4.3 (Confidentiality impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N).
A CWE-200: Information Exposure vulnerability exists in Easergy T300 with firmware V2.7.1 and older that exposes sensitive information to an actor not explicitly authorized to have access to that information.
A CWE-552: Files or Directories Accessible to External Parties vulnerability exists in Easergy T300 with firmware V2.7.1 and older that could expose files or directory content when access from an attacker is not restricted or incorrectly restricted.
A CWE-200: Information Exposure vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could cause disclosure of encrypted credentials when consulting the maintenance report.
Information Exposure vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause information to be exposed when an unauthorized file is uploaded.
A vulnerability exists in Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 that allows the use of outdated cipher suites and improper verification of peer SSL Certificate.
A CWE-20: Improper Input Validation vulnerability exists that could allow arbitrary files on the server to be read by authenticated users through a limited operating system service account. Affected Product: EcoStruxure Power Monitoring Expert (Versions 2020 and prior)
A CWE-798 use of hardcoded credentials vulnerability exists in BMX-NOR-0200H with firmware versions prior to V1.7 IR 19 which could cause a confidentiality issue when using FTP protocol.
A Credentials Management CWE-255 vulnerability exists in the APC UPS Network Management Card 2 AOS v6.5.6, which could cause Remote Monitoring Credentials to be viewed in plaintext when Remote Monitoring is enabled, and then disabled.
Schneider Electric StruxureWare Building Expert MPM before 2.15 does not use encryption for the client-server data stream, which allows remote attackers to discover credentials by sniffing the network.
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could cause Sensitive data such as login credentials being exposed when a Network is sniffed. Affected Product: Conext� ComBox (All Versions)
Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause a leak of SMTP credential used for mailbox authentication when an attacker can access a project file.
Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause protected derived function blocks to be read or modified by unauthorized users when accessing a project file.
Schneider Electric Ampla MES 6.4 provides capability to interact with data from third party databases. When connectivity to those databases is configured to use a SQL user name and password, an attacker may be able to sniff details from the connection string. Schneider Electric recommends that users of Ampla MES versions 6.4 and prior should upgrade to Ampla MES version 6.5 as soon as possible.
An information disclosure vulnerability exists in Schneider Electric's IGSS Mobile application version 3.01 and prior. Passwords are stored in clear text in the configuration which can result in exposure of sensitive information.
An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions. Log-in credentials are sent over the network with Base64 encoding leaving them susceptible to sniffing. Sniffed credentials could then be used to log into the web application.
A CWE-257: Storing Passwords in a Recoverable Format vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. Affected Products: Data Center Expert (Versions prior to V7.9.0)
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32520. Affected Products: Data Center Expert (Versions prior to V7.9.0)
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32518. Affected Products: Data Center Expert (Versions prior to V7.9.0)
CWE-522: Insufficiently Protected Credentials vulnerability exists that could cause unauthorized access to the project file in EcoStruxure Control Expert when a local user tampers with the memory of the engineering workstation.
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x stores the password in plaintext in a file that is in the same directory as the executable file. ISaGRAF Runtime reads the file and saves the data in a variable without any additional modification. A local, unauthenticated attacker could compromise the user passwords, resulting in information disclosure.
Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause unauthorized access to a project file protected by a password when this file is shared with untrusted sources. An attacker may bypass the password protection and be able to view and modify a project file.
In Vijeo Citect 7.30 and 7.40, and CitectSCADA 7.30 and 7.40, a vulnerability has been identified that may allow an authenticated local user access to Citect user credentials.
A CWE-522: Insufficiently Protected Credentials vulnerability exists in EcoStruxure Geo SCADA Expert 2019 (Original release and Monthly Updates to September 2020, from 81.7268.1 to 81.7578.1) and EcoStruxure Geo SCADA Expert 2020 (Original release and Monthly Updates to September 2020, from 83.7551.1 to 83.7578.1), that could cause exposure of credentials to server-side users when web users are logged in to Virtual ViewX.
An issue was discovered on Eaton UPS 9PX 8000 SP devices. The appliance discloses the user's password. The web page displayed by the appliance contains the password in cleartext. Passwords could be retrieved by browsing the source code of the webpage.
An issue was discovered in Grafana 5.4.0. Passwords for data sources used by Grafana (e.g., MySQL) are not encrypted. An admin user can reveal passwords for any data source by pressing the "Save and test" button within a data source's settings menu. When watching the transaction with Burp Proxy, the password for the data source is revealed and sent to the server. From a browser, a prompt to save the credentials is generated, and the password can be revealed by simply checking the "Show password" box.
IBM Business Automation Workflow 18.0, 19.0, 20.0, and 21.0 and IBM Business Process Manager 8.5 and 8.6 stores user credentials in plain clear text which can be read by a lprivileged user. IBM X-Force ID: 214346.
An issue was discovered on Eaton UPS 9PX 8000 SP devices. The appliance discloses the SNMP version 3 user's password. The web page displayed by the appliance contains the password in cleartext. Passwords of the read and write users could be retrieved by browsing the source code of the webpage.
The F5 BIG-IP Controller for Kubernetes 1.0.0-1.5.0 (k8s-bigip-crtl) passes BIG-IP username and password as command line parameters, which may lead to disclosure of the credentials used by the container.
An issue was discovered in Django 2.1 before 2.1.2, in which unprivileged users can read the password hashes of arbitrary accounts. The read-only password widget used by the Django Admin to display an obfuscated password hash was bypassed if a user has only the "view" permission (new in Django 2.1), resulting in display of the entire password hash to those users. This may result in a vulnerability for sites with legacy user accounts using insecure hashes.
An issue was discovered on Digi TransPort devices through 2021-07-21. An authenticated attacker may read a password file (with reversible passwords) from the device, which allows decoding of other users' passwords.
Dell Enterprise SONiC OS, versions 3.3.0 and earlier, contains a sensitive information disclosure vulnerability. An authenticated malicious user with access to the system may use the TACACS\Radius credentials stored to read sensitive information and use it in further attacks.
A insufficiently protected credentials in Fortinet FortiSDNConnector version 1.1.7 and below allows attacker to disclose third-party devices credential information via configuration page lookup.
Jenkins Fortify Plugin 19.1.29 and earlier stores proxy server passwords unencrypted in job config.xml files on the Jenkins master where they can be viewed by users with Extended Read permission, or access to the master file system.
IBM Jazz for Service Management and IBM Tivoli Netcool/OMNIbus_GUI 8.1.0 stores user credentials in plain clear text which can be read by an authenticated admin user. IBM X-Force ID: 204329.
Verba Collaboration Compliance and Quality Management Platform before 9.2.1.5545 has Incorrect Access Control.
Squash TM through 1.18.0 presents the cleartext passwords of external services in the administration panel, as demonstrated by a ta-server-password field in the HTML source code.
On systems running Arista EOS and CloudEOS with the affected release version, when using shared secret profiles the password configured for use by BiDirectional Forwarding Detection (BFD) will be leaked when displaying output over eAPI or other JSON outputs to other authenticated users on the device. The affected EOS Versions are: all releases in 4.22.x train, 4.23.9 and below releases in the 4.23.x train, 4.24.7 and below releases in the 4.24.x train, 4.25.4 and below releases in the 4.25.x train, 4.26.1 and below releases in the 4.26.x train
ovirt-engine API and administration web portal before versions 4.2.2.5, 4.1.11.2 is vulnerable to an exposure of Power Management credentials, including cleartext passwords to Host Administrators. A Host Administrator could use this flaw to gain access to the power management systems of hosts they control.
A exposure of sensitive information vulnerability exists in Jenkins z/OS Connector Plugin 1.2.6.1 and earlier in SCLMSCM.java that allows an attacker with local file system access or control of a Jenkins administrator's web browser (e.g. malicious extension) to retrieve the configured password.
The Ericsson-LG iPECS NMS A.1Ac web application discloses sensitive information such as the NMS admin credentials and the PostgreSQL database credentials to logged-in users via the responses to certain HTTP POST requests. In order to be able to see the credentials in cleartext, an attacker needs to be authenticated.
A exposure of sensitive information vulnerability exists in Jenkins Configuration as Code Plugin 0.7-alpha and earlier in DataBoundConfigurator.java, Attribute.java, BaseConfigurator.java, ExtensionConfigurator.java that allows attackers with access to Jenkins log files to obtain the passwords configured using Configuration as Code Plugin.
Cloud Controller API versions prior to 1.106.0 logs service broker credentials if the default value of db logging config field is changed. CAPI database logs service broker password in plain text whenever a job to clean up orphaned items is run by Cloud Controller.
The Philips DoseWise Portal web-based application versions 1.1.7.333 and 2.1.1.3069 stores login credentials in clear text within backend system files. CVSS v3 base score: 6.5, CVSS vector string: AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N.
Jenkins Jabber (XMPP) notifier and control Plugin 1.41 and earlier stores passwords unencrypted in its global configuration file on the Jenkins controller where they can be viewed by users with access to the Jenkins controller file system.
A vulnerability in the web-based management interface of Cisco Unified Communications Manager could allow an authenticated, remote attacker to view digest credentials in clear text. The vulnerability is due to the incorrect inclusion of saved passwords in configuration pages. An attacker could exploit this vulnerability by logging in to the Cisco Unified Communications Manager web-based management interface and viewing the source code for the configuration page. A successful exploit could allow the attacker to recover passwords and expose those accounts to further attack.
IBM Maximo for Civil Infrastructure 7.6.2 could allow a user to obtain sensitive information due to insecure storeage of authentication credentials. IBM X-Force ID: 196621.
Trendnet AC2600 TEW-827DRU version 2.08B01 leaks information via the ftp web page. Usernames and passwords for all ftp users are revealed in plaintext on the ftpserver.asp page.