In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, authenticated users can view passwords in clear text.
A CWE-20: Improper Input Validation vulnerability exists that could allow arbitrary files on the server to be read by authenticated users through a limited operating system service account. Affected Product: EcoStruxure Power Monitoring Expert (Versions 2020 and prior)
A CWE-200: Information Exposure vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could cause disclosure of encrypted credentials when consulting the maintenance report.
Information Exposure vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause information to be exposed when an unauthorized file is uploaded.
A CWE-200: Information Exposure vulnerability exists in Easergy T300 with firmware V2.7.1 and older that exposes sensitive information to an actor not explicitly authorized to have access to that information.
A vulnerability exists in Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 that allows the use of outdated cipher suites and improper verification of peer SSL Certificate.
A CWE-552: Files or Directories Accessible to External Parties vulnerability exists in Easergy T300 with firmware V2.7.1 and older that could expose files or directory content when access from an attacker is not restricted or incorrectly restricted.
In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, by sending a specially crafted request an authenticated user can view password in clear text and results in privilege escalation.
Vulnerability in the Java SE, Java SE Embedded, JRockit component of Oracle Java SE (subcomponent: LDAP). Supported versions that are affected are Java SE: 6u171, 7u161, 8u152 and 9.0.1; Java SE Embedded: 8u151; JRockit: R28.3.16. Easily exploitable vulnerability allows low privileged attacker with network access via multiple protocols to compromise Java SE, Java SE Embedded, JRockit. Successful attacks of this vulnerability can result in unauthorized read access to a subset of Java SE, Java SE Embedded, JRockit accessible data. Note: This vulnerability applies to client and server deployment of Java. This vulnerability can be exploited through sandboxed Java Web Start applications and sandboxed Java applets. It can also be exploited by supplying data to APIs in the specified Component without using sandboxed Java Web Start applications or sandboxed Java applets, such as through a web service. CVSS 3.0 Base Score 4.3 (Confidentiality impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N).
A CWE-798 use of hardcoded credentials vulnerability exists in BMX-NOR-0200H with firmware versions prior to V1.7 IR 19 which could cause a confidentiality issue when using FTP protocol.
CWE-522 Insufficiently Protected Credentials vulnerability that could cause unauthorized access and exposure of sensitive information when unauthenticated attacker accesses credentials stored within firmware or system files. With this credential an attacker could subsequently compromise the device if they have physical access to the device.
Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause unauthorized access to a project file protected by a password when this file is shared with untrusted sources. An attacker may bypass the password protection and be able to view and modify a project file.
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could cause Sensitive data such as login credentials being exposed when a Network is sniffed. Affected Product: Conext� ComBox (All Versions)
Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause protected derived function blocks to be read or modified by unauthorized users when accessing a project file.
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x stores the password in plaintext in a file that is in the same directory as the executable file. ISaGRAF Runtime reads the file and saves the data in a variable without any additional modification. A local, unauthenticated attacker could compromise the user passwords, resulting in information disclosure.
An information disclosure vulnerability exists in Schneider Electric's IGSS Mobile application version 3.01 and prior. Passwords are stored in clear text in the configuration which can result in exposure of sensitive information.
Schneider Electric Ampla MES 6.4 provides capability to interact with data from third party databases. When connectivity to those databases is configured to use a SQL user name and password, an attacker may be able to sniff details from the connection string. Schneider Electric recommends that users of Ampla MES versions 6.4 and prior should upgrade to Ampla MES version 6.5 as soon as possible.
An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions. Log-in credentials are sent over the network with Base64 encoding leaving them susceptible to sniffing. Sniffed credentials could then be used to log into the web application.
A CWE-522: Insufficiently Protected Credentials vulnerability exists in EcoStruxure Geo SCADA Expert 2019 (Original release and Monthly Updates to September 2020, from 81.7268.1 to 81.7578.1) and EcoStruxure Geo SCADA Expert 2020 (Original release and Monthly Updates to September 2020, from 83.7551.1 to 83.7578.1), that could cause exposure of credentials to server-side users when web users are logged in to Virtual ViewX.
In Vijeo Citect 7.30 and 7.40, and CitectSCADA 7.30 and 7.40, a vulnerability has been identified that may allow an authenticated local user access to Citect user credentials.
Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause a leak of SMTP credential used for mailbox authentication when an attacker can access a project file.
Schneider Electric StruxureWare Building Expert MPM before 2.15 does not use encryption for the client-server data stream, which allows remote attackers to discover credentials by sniffing the network.
A Credentials Management CWE-255 vulnerability exists in the APC UPS Network Management Card 2 AOS v6.5.6, which could cause Remote Monitoring Credentials to be viewed in plaintext when Remote Monitoring is enabled, and then disabled.
CWE-522: Insufficiently Protected Credentials vulnerability exists that could cause unauthorized access to the project file in EcoStruxure Control Expert when a local user tampers with the memory of the engineering workstation.
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32520. Affected Products: Data Center Expert (Versions prior to V7.9.0)
A CWE-257: Storing Passwords in a Recoverable Format vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. Affected Products: Data Center Expert (Versions prior to V7.9.0)
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32518. Affected Products: Data Center Expert (Versions prior to V7.9.0)
A vulnerability has been identified in SICAM GridEdge (Classic) (All versions < V2.6.6). The affected application discloses password hashes of other users upon request. This could allow an authenticated user to retrieve another user's password hash.
Jenkins Proxmox Plugin 0.5.0 and earlier stores the Proxmox Datacenter password unencrypted in the global config.xml file on the Jenkins controller where it can be viewed by users with access to the Jenkins controller file system.
Jenkins instant-messaging Plugin 1.41 and earlier stores passwords for group chats unencrypted in the global configuration file of plugins based on Jenkins instant-messaging Plugin on the Jenkins controller where they can be viewed by users with access to the Jenkins controller file system.
A malicious actor having access to the exported configuration file may obtain the stored credentials and thereby gain access to the protected resource. If the same passwords were used for other resources, further such assets may be compromised.
Jenkins dbCharts Plugin 0.5.2 and earlier stores JDBC connection passwords unencrypted in its global configuration file on the Jenkins controller where they can be viewed by users with access to the Jenkins controller file system.
Forms generated by JQueryForm.com before 2022-02-05 allows a remote authenticated attacker to access the cleartext credentials of all other form users. admin.php contains a hidden base64-encoded string with these credentials.
Jenkins Pipeline: Build Step Plugin 2.15 and earlier reveals password parameter default values when generating a pipeline script using the Pipeline Snippet Generator, allowing attackers with Item/Read permission to retrieve the default password parameter value from jobs.
Credentials are printed in clear text in the IBM Spectrum Protect Plus 10.1.0.0 through 10.1.9.3 virgo log file in certain cases. Credentials could be the remote vSnap, offload targets, or VADP credentials depending on the operation performed. Credentials that are using API key or certificate are not printed. IBM X-Force ID: 222231.
Information Exposure vulnerability in My Account Settings of Devolutions Remote Desktop Manager before 2022.1.8 allows authenticated users to access credentials of other users. This issue affects: Devolutions Remote Desktop Manager versions prior to 2022.1.8.
In GNU Mailman before 2.1.36, the CSRF token for the Cgi/admindb.py admindb page contains an encrypted version of the list admin password. This could potentially be cracked by a moderator via an offline brute-force attack.
Jenkins Google Compute Engine Plugin 4.3.8 and earlier stores private keys unencrypted in cloud agent config.xml files on the Jenkins controller where they can be viewed by users with Extended Read permission, or access to the Jenkins controller file system.
Apache Superset up to and including 1.3.1 allowed for database connections password leak for authenticated users. This information could be accessed in a non-trivial way.
IBM Business Automation Workflow 18.0, 19.0, 20.0, and 21.0 and IBM Business Process Manager 8.5 and 8.6 stores user credentials in plain clear text which can be read by a lprivileged user. IBM X-Force ID: 214346.
An issue was discovered on Digi TransPort devices through 2021-07-21. An authenticated attacker may read a password file (with reversible passwords) from the device, which allows decoding of other users' passwords.
Dell Enterprise SONiC OS, versions 3.3.0 and earlier, contains a sensitive information disclosure vulnerability. An authenticated malicious user with access to the system may use the TACACS\Radius credentials stored to read sensitive information and use it in further attacks.
Brocade SANnav before Brocade SANvav v. 2.2.0.2 and Brocade SANanv v.2.1.1.8 logs the Brocade Fabric OS switch password in plain text in asyncjobscheduler-manager.log
On systems running Arista EOS and CloudEOS with the affected release version, when using shared secret profiles the password configured for use by BiDirectional Forwarding Detection (BFD) will be leaked when displaying output over eAPI or other JSON outputs to other authenticated users on the device. The affected EOS Versions are: all releases in 4.22.x train, 4.23.9 and below releases in the 4.23.x train, 4.24.7 and below releases in the 4.24.x train, 4.25.4 and below releases in the 4.25.x train, 4.26.1 and below releases in the 4.26.x train
Jenkins incapptic connect uploader Plugin 1.15 and earlier stores tokens unencrypted in job config.xml files on the Jenkins controller where they can be viewed by users with Extended Read permission, or access to the Jenkins controller file system.
IBM Jazz for Service Management and IBM Tivoli Netcool/OMNIbus_GUI 8.1.0 stores user credentials in plain clear text which can be read by an authenticated admin user. IBM X-Force ID: 204329.
Jenkins Vmware vRealize CodeStream Plugin 1.2 and earlier stores passwords unencrypted in job config.xml files on the Jenkins controller where they can be viewed by users with Extended Read permission, or access to the Jenkins controller file system.
Jenkins GitLab Authentication Plugin 1.13 and earlier stores the GitLab client secret unencrypted in the global config.xml file on the Jenkins controller where it can be viewed by users with access to the Jenkins controller file system.
Cloud Controller API versions prior to 1.106.0 logs service broker credentials if the default value of db logging config field is changed. CAPI database logs service broker password in plain text whenever a job to clean up orphaned items is run by Cloud Controller.