A vulnerability has been identified in XHQ (All Versions < 6.1). The application's web server could expose non-sensitive information about the server's architecture. This could allow an attacker to adapt further attacks to the version in place.
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could gain access to directory listings of the server by sending specifically crafted packets to 80/tcp, 8095/tcp or 8080/tcp. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SINAMICS PERFECT HARMONY GH180 with NXG I control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- (All Versions with option G21, G22, G23, G26, G28, G31, G32, G38, G43 or G46), SINAMICS PERFECT HARMONY GH180 with NXG II control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- (All Versions with option G21, G22, G23, G26, G28, G31, G32, G38, G43 or G46). An improperly configured Parameter Read/Write execution via Field bus network may cause the controller to restart. The vulnerability could be exploited by an attacker with network access to the device. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise the availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could gain access to path and filenames on the server by sending specifically crafted packets to 1099/tcp. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). The Application Server exposes directory listings and files containing sensitive information. This vulnerability is independent from CVE-2019-18286. Please note that an attacker needs to have access to the Application Highway in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could be able to enumerate valid user names by sending specifically crafted packets to 8090/tcp. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SIMOTION C240 (All versions >= V5.4 < V5.5 SP1), SIMOTION C240 PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D410-2 DP (All versions >= V5.4 < V5.5 SP1), SIMOTION D410-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D425-2 DP (All versions >= V5.4 < V5.5 SP1), SIMOTION D425-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D435-2 DP (All versions >= V5.4 < V5.5 SP1), SIMOTION D435-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D445-2 DP/PN (All versions >= V5.4), SIMOTION D445-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D455-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION P320-4 E (All versions >= V5.4), SIMOTION P320-4 S (All versions >= V5.4). When operated with Security Level Low the device does not protect access to certain services relevant for debugging. This could allow an unauthenticated attacker to extract confidential technology object (TO) configuration from the device.
A vulnerability has been identified in Teamcenter Active Workspace V4 (All versions < V4.3.9), Teamcenter Active Workspace V5.0 (All versions < V5.0.7), Teamcenter Active Workspace V5.1 (All versions < V5.1.4). By sending malformed requests, a remote attacker could leak an application token due to an error not properly handled by the system.
An issue was discovered on Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00. The integrated web server (port 80/tcp) of the affected devices could allow unauthenticated remote attackers to obtain sensitive device information over the network.
A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 V6 and earlier CPU family (All versions), SIMATIC S7-400 V7 CPU family (All versions), SIMATIC S7-410 V8 CPU family (All versions), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) (All versions). An attacker with network access to port 102/tcp (ISO-TSAP) or via Profibus could obtain credentials from the PLC if protection-level 2 is configured on the affected devices.
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V1.81.2). An attacker with network access to the integrated web server on port 80/tcp could obtain the session ID of an active user session. A user must be logged in to the web interface. Siemens recommends to use the integrated webserver on port 80/tcp only in trusted networks.
Siemens SIMATIC STEP 7 (TIA Portal) before 14 uses an improper format for managing TIA project files during version updates, which makes it easier for local users to obtain sensitive configuration information via unspecified vectors.
The integrated web server on Siemens SCALANCE M-800 and S615 modules with firmware before 4.02 does not set the secure flag for the session cookie in an https session, which makes it easier for remote attackers to capture this cookie by intercepting its transmission within an http session.
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could be able to gain access to logs and configuration files by sending specifically crafted packets to 80/tcp. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
Siemens SICAM PAS through 8.07 allows local users to obtain sensitive configuration information by leveraging database stoppage.
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could gain access to filenames on the server by sending specifically crafted packets to 8090/tcp. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
Siemens SIMATIC WinCC 7.0 through SP3 and 7.2 allows remote attackers to read arbitrary WinCC station files via crafted packets.
Siemens APOGEE Insight uses weak permissions for the application folder, which allows local users to obtain sensitive information or modify data via unspecified vectors.
curl 7.1.1 to and including 7.75.0 is vulnerable to an "Exposure of Private Personal Information to an Unauthorized Actor" by leaking credentials in the HTTP Referer: header. libcurl does not strip off user credentials from the URL when automatically populating the Referer: HTTP request header field in outgoing HTTP requests, and therefore risks leaking sensitive data to the server that is the target of the second HTTP request.
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). The Application Server exposes directory listings and files containing sensitive information. This vulnerability is independent from CVE-2019-18287. Please note that an attacker needs to have access to the Application Highway in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02. The integrated web server (port 80/tcp) of the affected devices could allow remote attackers to obtain a limited amount of device memory content if network access was obtained. This vulnerability only affects EN100 Ethernet module included in SIPROTEC4 and SIPROTEC Compact devices.
A vulnerability has been identified in firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02; SIPROTEC 7SJ686 : All versions < V 4.83; SIPROTEC 7UT686 : All versions < V 4.01; SIPROTEC 7SD686 : All versions < V 4.03; SIPROTEC 7SJ66 : All versions < V 4.20. The integrated web server (port 80/tcp) of the affected devices could allow remote attackers to obtain sensitive device information if network access was obtained.
The Siemens SIMATIC WinCC Sm@rtClient and Sm@rtClient Lite applications before 01.00.01.00 for Android do not properly store passwords, which allows physically proximate attackers to obtain sensitive information via unspecified vectors.
Siemens Ruggedcom WIN51xx devices with firmware before SS4.4.4624.35, WIN52xx devices with firmware before SS4.4.4624.35, WIN70xx devices with firmware before BS4.4.4621.32, and WIN72xx devices with firmware before BS4.4.4621.32 allow context-dependent attackers to discover password hashes by reading (1) files or (2) security logs.
A vulnerability has been identified in Spectrum Power 4 (All versions < V4.70 SP8). If configured in an insecure manner, the web server might be susceptible to a directory listing attack.
A vulnerability has been identified in Desigo Insight (All versions). Some error messages in the web application show the absolute path to the requested resource. This could allow an authenticated attacker to retrieve additional information about the host system.
Siemens SINUMERIK Integrate Operate Clients between 2.0.3.00.016 (including) and 2.0.6 (excluding) and between 3.0.4.00.032 (including) and 3.0.6 (excluding) contain a vulnerability that could allow an attacker to read and manipulate data in TLS sessions while performing a man-in-the-middle (MITM) attack.
A vulnerability has been identified in SIMATIC Reader RF610R CMIIT (6GT2811-6BC10-2AA0) (All versions < V4.2), SIMATIC Reader RF610R ETSI (6GT2811-6BC10-0AA0) (All versions < V4.2), SIMATIC Reader RF610R FCC (6GT2811-6BC10-1AA0) (All versions < V4.2), SIMATIC Reader RF615R CMIIT (6GT2811-6CC10-2AA0) (All versions < V4.2), SIMATIC Reader RF615R ETSI (6GT2811-6CC10-0AA0) (All versions < V4.2), SIMATIC Reader RF615R FCC (6GT2811-6CC10-1AA0) (All versions < V4.2), SIMATIC Reader RF650R ARIB (6GT2811-6AB20-4AA0) (All versions < V4.2), SIMATIC Reader RF650R CMIIT (6GT2811-6AB20-2AA0) (All versions < V4.2), SIMATIC Reader RF650R ETSI (6GT2811-6AB20-0AA0) (All versions < V4.2), SIMATIC Reader RF650R FCC (6GT2811-6AB20-1AA0) (All versions < V4.2), SIMATIC Reader RF680R ARIB (6GT2811-6AA10-4AA0) (All versions < V4.2), SIMATIC Reader RF680R CMIIT (6GT2811-6AA10-2AA0) (All versions < V4.2), SIMATIC Reader RF680R ETSI (6GT2811-6AA10-0AA0) (All versions < V4.2), SIMATIC Reader RF680R FCC (6GT2811-6AA10-1AA0) (All versions < V4.2), SIMATIC Reader RF685R ARIB (6GT2811-6CA10-4AA0) (All versions < V4.2), SIMATIC Reader RF685R CMIIT (6GT2811-6CA10-2AA0) (All versions < V4.2), SIMATIC Reader RF685R ETSI (6GT2811-6CA10-0AA0) (All versions < V4.2), SIMATIC Reader RF685R FCC (6GT2811-6CA10-1AA0) (All versions < V4.2), SIMATIC RF1140R (6GT2831-6CB00) (All versions < V1.1), SIMATIC RF1170R (6GT2831-6BB00) (All versions < V1.1), SIMATIC RF166C (6GT2002-0EE20) (All versions < V2.2), SIMATIC RF185C (6GT2002-0JE10) (All versions < V2.2), SIMATIC RF186C (6GT2002-0JE20) (All versions < V2.2), SIMATIC RF186CI (6GT2002-0JE50) (All versions < V2.2), SIMATIC RF188C (6GT2002-0JE40) (All versions < V2.2), SIMATIC RF188CI (6GT2002-0JE60) (All versions < V2.2), SIMATIC RF360R (6GT2801-5BA30) (All versions < V2.2). The service log files of the affected application can be accessed without proper authentication. This could allow an unauthenticated attacker to get access to sensitive information.
A vulnerability has been identified in SIMATIC CP 343-1 Advanced (incl. SIPLUS NET variant) (All versions < V3.0.53), SIMATIC CP 443-1 Advanced (incl. SIPLUS NET variant) (All versions < V3.2.17), SIMATIC S7-300 PN/DP CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP CPU family (incl. SIPLUS variants) (All versions). The integrated web server delivers cookies without the "secure" flag. Modern browsers interpreting the flag would mitigate potential data leakage in case of clear text transmission.
In check_user_token in util.c in the Yubico PAM module (aka pam_yubico) 2.18 through 2.25, successful logins can leak file descriptors to the auth mapping file, which can lead to information disclosure (serial number of a device) and/or DoS (reaching the maximum number of file descriptors).
On Junos OS, rpcbind should only be listening to port 111 on the internal routing instance (IRI). External packets destined to port 111 should be dropped. Due to an information leak vulnerability, responses were being generated from the source address of the management interface (e.g. fxp0) thus disclosing internal addressing and existence of the management interface itself. A high rate of crafted packets destined to port 111 may also lead to a partial Denial of Service (DoS). Note: Systems with fxp0 disabled or unconfigured are not vulnerable to this issue. This issue only affects Junos OS releases based on FreeBSD 10 or higher (typically Junos OS 15.1+). Administrators can confirm whether systems are running a version of Junos OS based on FreeBSD 10 or higher by typing: user@junos> show version | match kernel JUNOS OS Kernel 64-bit [20181214.223829_fbsd-builder_stable_10] Affected releases are Juniper Networks Junos OS: 15.1 versions prior to 15.1F6-S12, 15.1R7-S4; 15.1X53 versions prior to 15.1X53-D236; 16.1 versions prior to 16.1R7-S1; 16.2 versions prior to 16.2R2-S9; 17.1 versions prior to 17.1R3; 17.2 versions prior to 17.2R1-S8; 17.3 versions prior to 17.3R2; 17.4 versions prior to 17.4R1-S1, 17.4R1-S7, 17.4R2. This issue does not affect Junos OS releases prior to 15.1.
The gdImageRotateInterpolated function in ext/gd/libgd/gd_interpolation.c in PHP before 5.5.31, 5.6.x before 5.6.17, and 7.x before 7.0.2 allows remote attackers to obtain sensitive information or cause a denial of service (out-of-bounds read and application crash) via a large bgd_color argument to the imagerotate function.
OCaml before 4.03.0 does not properly handle sign extensions, which allows remote attackers to conduct buffer overflow attacks or obtain sensitive information as demonstrated by a long string to the String.copy function.
Heap-based buffer overflow in the find_fixedlength function in pcre_compile.c in PCRE before 8.38 allows remote attackers to cause a denial of service (crash) or obtain sensitive information from heap memory and possibly bypass the ASLR protection mechanism via a crafted regular expression with an excess closing parenthesis.
Possible information exposure and denial of service due to NAS not dropping messages when integrity check fails in Snapdragon Auto, Snapdragon Compute, Snapdragon Connectivity, Snapdragon Consumer IOT, Snapdragon Industrial IOT, Snapdragon IoT, Snapdragon Mobile, Snapdragon Voice & Music, Snapdragon Wearables
X.Org Server (aka xserver and xorg-server) before 1.16.3 and 1.17.x before 1.17.1 allows remote attackers to obtain sensitive information from process memory or cause a denial of service (crash) via a crafted string length value in a XkbSetGeometry request.
The mod_auth_mellon module before 0.8.1 allows remote attackers to obtain sensitive information or cause a denial of service (segmentation fault) via unspecified vectors related to a "session overflow" involving "sessions overlapping in memory."
In Apache httpd before 2.2.34 and 2.4.x before 2.4.27, the value placeholder in [Proxy-]Authorization headers of type 'Digest' was not initialized or reset before or between successive key=value assignments by mod_auth_digest. Providing an initial key with no '=' assignment could reflect the stale value of uninitialized pool memory used by the prior request, leading to leakage of potentially confidential information, and a segfault in other cases resulting in denial of service.
An Exposure of System Data vulnerability in Juniper Networks Junos OS and Junos OS Evolved, where a sensitive system-level resource is not being sufficiently protected, allows a network-based unauthenticated attacker to send specific traffic which partially reaches this resource. A high rate of specific traffic may lead to a partial Denial of Service (DoS) as the CPU utilization of the RE is significantly increased. The SNMP Agent Extensibility (agentx) process should only be listening to TCP port 705 on the internal routing instance. External connections destined to port 705 should not be allowed. This issue affects: Juniper Networks Junos OS: 15.1 versions prior to 15.1R7-S9; 17.3 versions prior to 17.3R3-S12; 17.4 versions prior to 17.4R2-S13, 17.4R3-S5; 18.3 versions prior to 18.3R3-S5; 18.4 versions prior to 18.4R2-S8; 19.1 versions prior to 19.1R3-S5; 19.2 versions prior to 19.2R3-S2; 19.3 versions prior to 19.3R2-S6, 19.3R3-S2; 19.4 versions prior to 19.4R1-S4, 19.4R2-S4, 19.4R3; 20.1 versions prior to 20.1R2; 20.2 versions prior to 20.2R2; 20.3 versions prior to 20.3R2. Juniper Networks Junos OS Evolved versions prior to 20.3R2-EVO. This issue does not affect Juniper Networks Junos OS versions prior to 13.2R1.
Zyxel P2000W Version 1 VOIP WIFI Phone Wj.00.10 allows remote attackers to obtain sensitive information and possibly cause a denial of service via a direct connection to UDP port 9090, which is undocumented and does not require authentication.
A flaw was found in podman. The `podman machine` function (used to create and manage Podman virtual machine containing a Podman process) spawns a `gvproxy` process on the host system. The `gvproxy` API is accessible on port 7777 on all IP addresses on the host. If that port is open on the host's firewall, an attacker can potentially use the `gvproxy` API to forward ports on the host to ports in the VM, making private services on the VM accessible to the network. This issue could be also used to interrupt the host's services by forwarding all ports to the VM.
Pomerium is an identity-aware access proxy. In distributed service mode, Pomerium's Authenticate service exposes pprof debug and prometheus metrics handlers to untrusted traffic. This can leak potentially sensitive environmental information or lead to limited denial of service conditions. This issue is patched in version v0.17.1 Workarounds: Block access to `/debug` and `/metrics` paths on the authenticate service. This can be done with any L7 proxy, including Pomerium's own proxy service.
An exploitable arbitrary memory read vulnerability exists in the KCodes NetUSB.ko kernel module which enables the ReadySHARE Printer functionality of at least two NETGEAR Nighthawk Routers and potentially several other vendors/products. A specially crafted index value can cause an invalid memory read, resulting in a denial of service or remote information disclosure. An unauthenticated attacker can send a crafted packet on the local network to trigger this vulnerability.
Escalation of privilege vulnerability in admin portal for Intel Unite App versions 3.1.32.12, 3.1.41.18 and 3.1.45.26 allows an attacker with network access to cause a denial of service and/or information disclosure.
An information disclosure vulnerability in the Android media framework (libavc). Product: Android. Versions: 7.0, 7.1.1, 7.1.2, 8.0, 8.1. Android ID: A-64380237.
An information disclosure vulnerability in the Android media framework (libhevc). Product: Android. Versions: 7.0, 7.1.1, 7.1.2, 8.0, 8.1. Android ID: A-65034175.
An information disclosure vulnerability in the Android media framework (n/a). Product: Android. Versions: 7.0, 7.1.1, 7.1.2, 8.0. Android ID A-65719872.
An information disclosure vulnerability in the Android media framework (n/a). Product: Android. Versions: 7.0, 7.1.1, 7.1.2, 8.0. Android ID A-65025028.
An information disclosure vulnerability in the Android media framework (libhevc). Product: Android. Versions: 7.0, 7.1.1, 7.1.2, 8.0. Android ID: A-65123471.
decoder/impeg2d_bitstream.c in mediaserver in Android 6.x before 2016-07-01 allows attackers to obtain sensitive information from process memory or cause a denial of service (out-of-bounds read) via a crafted application, aka internal bug 28168413.