Vulnerability Details :

CVE-2018-7759

Summary
Assigner-schneider
Assigner Org ID-076d1eb6-cfab-4401-b34d-6dfc2a413bdb
Published At-18 Apr, 2018 | 20:00
Updated At-05 Aug, 2024 | 06:37
Rejected At-
Credits

A buffer overflow vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. The buffer overflow vulnerability is caused by the length of the source string specified (instead of the buffer size) as the number of bytes to be copied.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:schneider
Assigner Org ID:076d1eb6-cfab-4401-b34d-6dfc2a413bdb
Published At:18 Apr, 2018 | 20:00
Updated At:05 Aug, 2024 | 06:37
Rejected At:
▼CVE Numbering Authority (CNA)

A buffer overflow vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. The buffer overflow vulnerability is caused by the length of the source string specified (instead of the buffer size) as the number of bytes to be copied.

Affected Products
Vendor
Schneider Electric SESchneider Electric SE
Product
Modicon M340, Modicon Premium, Modicon Quantum, BMXNOR0200
Versions
Affected
  • All Modicon M340, Premium, Quantum PLCs and BMXNOR0200
Problem Types
TypeCWE IDDescription
textN/ABuffer overflow
Type: text
CWE ID: N/A
Description: Buffer overflow
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.schneider-electric.com/en/download/document/SEVD-2018-081-02/
x_refsource_CONFIRM
Hyperlink: https://www.schneider-electric.com/en/download/document/SEVD-2018-081-02/
Resource:
x_refsource_CONFIRM
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.schneider-electric.com/en/download/document/SEVD-2018-081-02/
x_refsource_CONFIRM
x_transferred
Hyperlink: https://www.schneider-electric.com/en/download/document/SEVD-2018-081-02/
Resource:
x_refsource_CONFIRM
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cybersecurity@se.com
Published At:18 Apr, 2018 | 20:29
Updated At:10 Apr, 2024 | 12:28

A buffer overflow vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. The buffer overflow vulnerability is caused by the length of the source string specified (instead of the buffer size) as the number of bytes to be copied.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.07.5HIGH
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Primary2.05.0MEDIUM
AV:N/AC:L/Au:N/C:N/I:N/A:P
Type: Primary
Version: 3.0
Base score: 7.5
Base severity: HIGH
Vector:
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Type: Primary
Version: 2.0
Base score: 5.0
Base severity: MEDIUM
Vector:
AV:N/AC:L/Au:N/C:N/I:N/A:P
CPE Matches

Schneider Electric SE
schneider-electric
>>bmxnor0200_firmware>>-
cpe:2.3:o:schneider-electric:bmxnor0200_firmware:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>bmxnor0200>>-
cpe:2.3:h:schneider-electric:bmxnor0200:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>bmxnor0200h_firmware>>-
cpe:2.3:o:schneider-electric:bmxnor0200h_firmware:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>bmxnor0200h>>-
cpe:2.3:h:schneider-electric:bmxnor0200h:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140cpu65150_firmware>>-
cpe:2.3:o:schneider-electric:140cpu65150_firmware:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140cpu65150>>-
cpe:2.3:h:schneider-electric:140cpu65150:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140cpu31110_firmware>>-
cpe:2.3:o:schneider-electric:140cpu31110_firmware:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140cpu31110>>-
cpe:2.3:h:schneider-electric:140cpu31110:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140cpu43412u_firmware>>-
cpe:2.3:o:schneider-electric:140cpu43412u_firmware:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140cpu43412u>>-
cpe:2.3:h:schneider-electric:140cpu43412u:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140cpu65160_firmware>>-
cpe:2.3:o:schneider-electric:140cpu65160_firmware:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140cpu65160>>-
cpe:2.3:h:schneider-electric:140cpu65160:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140cpu65260_firmware>>-
cpe:2.3:o:schneider-electric:140cpu65260_firmware:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140cpu65260>>-
cpe:2.3:h:schneider-electric:140cpu65260:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140cpu65860_firmware>>-
cpe:2.3:o:schneider-electric:140cpu65860_firmware:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140cpu65860>>-
cpe:2.3:h:schneider-electric:140cpu65860:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140cpu65160s_firmware>>-
cpe:2.3:o:schneider-electric:140cpu65160s_firmware:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140cpu65160s>>-
cpe:2.3:h:schneider-electric:140cpu65160s:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140cpu65150c_firmware>>-
cpe:2.3:o:schneider-electric:140cpu65150c_firmware:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140cpu65150c>>-
cpe:2.3:h:schneider-electric:140cpu65150c:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140cpu31110c_firmware>>-
cpe:2.3:o:schneider-electric:140cpu31110c_firmware:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140cpu31110c>>-
cpe:2.3:h:schneider-electric:140cpu31110c:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140cpu43412uc_firmware>>-
cpe:2.3:o:schneider-electric:140cpu43412uc_firmware:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140cpu43412uc>>-
cpe:2.3:h:schneider-electric:140cpu43412uc:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140cpu65160c_firmware>>-
cpe:2.3:o:schneider-electric:140cpu65160c_firmware:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140cpu65160c>>-
cpe:2.3:h:schneider-electric:140cpu65160c:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140cpu65160c_firmware>>-
cpe:2.3:o:schneider-electric:140cpu65160c_firmware:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140cpu65160c>>-
cpe:2.3:h:schneider-electric:140cpu65160c:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140cpu65260c_firmware>>-
cpe:2.3:o:schneider-electric:140cpu65260c_firmware:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140cpu65260c>>-
cpe:2.3:h:schneider-electric:140cpu65260c:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140cpu65860c_firmware>>-
cpe:2.3:o:schneider-electric:140cpu65860c_firmware:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140cpu65860c>>-
cpe:2.3:h:schneider-electric:140cpu65860c:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m340_bmxp341000_firmware>>-
cpe:2.3:o:schneider-electric:modicon_m340_bmxp341000_firmware:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m340_bmxp341000>>-
cpe:2.3:h:schneider-electric:modicon_m340_bmxp341000:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m340_bmxp342000_firmware>>-
cpe:2.3:o:schneider-electric:modicon_m340_bmxp342000_firmware:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m340_bmxp342000>>-
cpe:2.3:h:schneider-electric:modicon_m340_bmxp342000:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m340_bmxp3420102_firmware>>-
cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420102_firmware:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m340_bmxp3420102>>-
cpe:2.3:h:schneider-electric:modicon_m340_bmxp3420102:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m340_bmxp3420102cl_firmware>>-
cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420102cl_firmware:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m340_bmxp3420102cl>>-
cpe:2.3:h:schneider-electric:modicon_m340_bmxp3420102cl:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m340_bmxp342020_firmware>>-
cpe:2.3:o:schneider-electric:modicon_m340_bmxp342020_firmware:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m340_bmxp342020>>-
cpe:2.3:h:schneider-electric:modicon_m340_bmxp342020:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m340_bmxp3420302_firmware>>-
cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420302_firmware:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m340_bmxp3420302>>-
cpe:2.3:h:schneider-electric:modicon_m340_bmxp3420302:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m340_bmxp3420302cl_firmware>>-
cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420302cl_firmware:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m340_bmxp3420302cl>>-
cpe:2.3:h:schneider-electric:modicon_m340_bmxp3420302cl:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m340_bmxp3420302h_firmware>>-
cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420302h_firmware:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m340_bmxp3420302h>>-
cpe:2.3:h:schneider-electric:modicon_m340_bmxp3420302h:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m340_bmxp342020h_firmware>>-
cpe:2.3:o:schneider-electric:modicon_m340_bmxp342020h_firmware:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m340_bmxp342020h>>-
cpe:2.3:h:schneider-electric:modicon_m340_bmxp342020h:-:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-119Primarynvd@nist.gov
CWE ID: CWE-119
Type: Primary
Source: nvd@nist.gov
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://www.schneider-electric.com/en/download/document/SEVD-2018-081-02/cybersecurity@se.com
Vendor Advisory
Hyperlink: https://www.schneider-electric.com/en/download/document/SEVD-2018-081-02/
Source: cybersecurity@se.com
Resource:
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

798Records found

CVE-2022-24314
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.63% / 69.30%
||
7 Day CHG~0.00%
Published-09 Feb, 2022 | 22:05
Updated-03 Aug, 2024 | 04:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-125: Out-of-bounds Read vulnerability exists that could cause memory leaks potentially resulting in denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_system_data_serverInteractive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
CWE ID-CWE-125
Out-of-bounds Read
CVE-2022-24315
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.64% / 69.69%
||
7 Day CHG~0.00%
Published-09 Feb, 2022 | 22:05
Updated-03 Aug, 2024 | 04:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_system_data_serverInteractive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
CWE ID-CWE-125
Out-of-bounds Read
CVE-2022-24321
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.46% / 63.00%
||
7 Day CHG~0.00%
Published-09 Feb, 2022 | 22:05
Updated-03 Aug, 2024 | 04:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause Denial of Service against the Geo SCADA server when receiving a malformed HTTP request. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)

Action-Not Available
Vendor-n/a
Product-clearscadaecostruxure_geo_scada_expert_2020ecostruxure_geo_scada_expert_2019ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)
CWE ID-CWE-754
Improper Check for Unusual or Exceptional Conditions
CVE-2022-22724
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.48% / 64.19%
||
7 Day CHG~0.00%
Published-04 Feb, 2022 | 22:29
Updated-03 Aug, 2024 | 03:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-400: Uncontrolled Resource Consumption vulnerability exists that could cause a denial of service on ports 80 (HTTP) and 502 (Modbus), when sending a large number of TCP RST or FIN packets to any open TCP port of the PLC. Affected Product: Modicon M340 CPUs: BMXP34 (All Versions)

Action-Not Available
Vendor-n/a
Product-modicon_m340_bmxp341000_firmwaremodicon_m340_bmxp342030_firmwaremodicon_m340_bmxp342000modicon_m340_bmxp342010_firmwaremodicon_m340_bmxp341000modicon_m340_bmxp342000_firmwaremodicon_m340_bmxp3420102_firmwaremodicon_m340_bmxp3420302modicon_m340_bmxp3420102modicon_m340_bmxp342030modicon_m340_bmxp3420302_firmwaremodicon_m340_bmxp342010Modicon M340 CPUs: BMXP34 (All Versions)
CWE ID-CWE-400
Uncontrolled Resource Consumption
CVE-2019-6856
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.37% / 57.91%
||
7 Day CHG~0.00%
Published-06 Jan, 2020 | 22:57
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when writing specific physical memory blocks using Modbus TCP.

Action-Not Available
Vendor-
Product-140cpu67260_firmware140cpu67261_firmwaretsxp573634m140cpu65150tsxp571634m140cpu67861modicon_m580_firmwaretsxh5744m_firmwaretsxh5744m140cpu65160_firmware140cpu67160s_firmware140cpu65160s_firmware140cpu67160_firmware140cpu65860_firmwaretsxp574634m_firmwaretsxp575634mmodicon_m580140cpu65860tsxp575634m_firmwaretsxh5724m_firmware140cpu65160tsxp573634m_firmwaretsxp57454m_firmware140cpu67160140cpu67861_firmwaretsxp57254m_firmwaretsxp57304mtsxp572634mtsxp574634mtsxh5724mtsxp57304m_firmwaretsxp57204m_140cpu67261140cpu67060_firmwaretsxp576634m_firmware140cpu65160s140cpu65260_firmware140cpu67160stsxp576634m_tsxp57154m_firmwaretsxp57154mtsxp57454mmodicon_m340tsxp57254mtsxp57554mtsxp572634m_firmwaretsxp57104m_firmware140cpu67260tsxp57104mtsxp57354mtsxp57354m_firmware140cpu65150_firmwaretsxp57204m_firmwaretsxp57554m_firmware140cpu65260140cpu67060tsxp571634m_firmwaremodicon_m340_firmwareModicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions)
CWE ID-CWE-754
Improper Check for Unusual or Exceptional Conditions
CVE-2019-6819
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.47% / 63.53%
||
7 Day CHG~0.00%
Published-22 May, 2019 | 19:45
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists which could cause a possible Denial of Service when specific Modbus frames are sent to the controller in the products: Modicon M340 - firmware versions prior to V3.01, Modicon M580 - firmware versions prior to V2.80, All firmware versions of Modicon Quantum and Modicon Premium.

Action-Not Available
Vendor-n/a
Product-bmeh584040cmodicon_quantum_firmwaremodicon_m580_firmwarebmeh584040bmeh582040cmodicon_premium_firmwaremodicon_m340_bmxp3420102clmodicon_m580_bmep583020modicon_m580_bmep586040modicon_m340_bmxp342000modicon_m580_bmep584040modicon_m580_bmep582020modicon_m340_bmxp341000modicon_m340_bmxp3420302hmodicon_m580_bmep585040cmodicon_m580_bmep584040smodicon_m580_bmep583040modicon_m340_bmxp341000hmodicon_m580_bmep582040modicon_m580_bmep585040modicon_m340_bmxp3420302clmodicon_m580_bmep582040hbmeh586040modicon_m340_bmxp3420302modicon_premiummodicon_m580_bmep584020modicon_m340_bmxp342020modicon_m580_bmep582040smodicon_quantummodicon_m340_bmxp342020hmodicon_m580_bmep581020modicon_m580_bmep586040cbmeh586040cmodicon_m580_bmep581020hmodicon_m580_bmep582020hbmeh582040modicon_m340_bmxp3420102modicon_m340_firmwareModicon Controllers, Modicon M340 - firmware versions prior to V3.01 Modicon M580 - firmware versions prior to V2.80 All firmware versions of Modicon Quantum and Modicon Premium
CWE ID-CWE-754
Improper Check for Unusual or Exceptional Conditions
CVE-2019-6848
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.6||HIGH
EPSS-0.46% / 63.15%
||
7 Day CHG~0.00%
Published-29 Oct, 2019 | 14:53
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580 CPU (BMEx58*) and Modicon M580 communication module (BMENOC0311, BMENOC0321) (see notification for version info), which could cause a Denial of Service attack on the PLC when sending specific data on the REST API of the controller/communication module.

Action-Not Available
Vendor-n/a
Product-modicon_bmenoc_0321_firmwaremodicon_m580_firmwaremodicon_bmenoc_0321modicon_bmenoc_0311_firmwaremodicon_bmenoc_0311modicon_m580Modicon M580 CPU (BMEx58*) and Modicon M580 communication module (BMENOC0311, BMENOC0321) (see notification for version info)
CWE ID-CWE-755
Improper Handling of Exceptional Conditions
CVE-2019-6857
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.37% / 57.91%
||
7 Day CHG~0.00%
Published-06 Jan, 2020 | 22:57
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service of the controller when reading specific memory blocks using Modbus TCP.

Action-Not Available
Vendor-
Product-140cpu67260_firmware140cpu67261_firmwaretsxp573634m140cpu65150tsxp571634m140cpu67861modicon_m580_firmwaretsxh5744m_firmwaretsxh5744m140cpu65160_firmware140cpu67160s_firmware140cpu65160s_firmware140cpu67160_firmware140cpu65860_firmwaretsxp574634m_firmwaretsxp575634mmodicon_m580140cpu65860tsxp575634m_firmwaretsxh5724m_firmware140cpu65160tsxp573634m_firmwaretsxp57454m_firmware140cpu67160140cpu67861_firmwaretsxp57254m_firmwaretsxp57304mtsxp572634mtsxp574634mtsxh5724mtsxp57304m_firmwaretsxp57204m_140cpu67261140cpu67060_firmwaretsxp576634m_firmware140cpu65160s140cpu65260_firmware140cpu67160stsxp576634m_tsxp57154m_firmwaretsxp57154mtsxp57454mmodicon_m340tsxp57254mtsxp57554mtsxp572634m_firmwaretsxp57104m_firmware140cpu67260tsxp57104mtsxp57354mtsxp57354m_firmware140cpu65150_firmwaretsxp57204m_firmwaretsxp57554m_firmware140cpu65260140cpu67060tsxp571634m_firmwaremodicon_m340_firmwareModicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions)
CWE ID-CWE-754
Improper Check for Unusual or Exceptional Conditions
CVE-2021-22736
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.39% / 59.35%
||
7 Day CHG~0.00%
Published-26 May, 2021 | 19:19
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause a denial of service when an unauthorized file is uploaded.

Action-Not Available
Vendor-n/a
Product-homelynkspacelynk_firmwarehomelynk_firmwarespacelynkhomeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2021-22824
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.63% / 69.30%
||
7 Day CHG~0.00%
Published-11 Feb, 2022 | 17:40
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in denial of service, due to missing length check on user-supplied data from a constructed message received on the network. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_system_data_collectorInteractive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2021-22792
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.46% / 63.08%
||
7 Day CHG~0.00%
Published-02 Sep, 2021 | 16:53
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-476: NULL Pointer Dereference vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers BMEP* and BMEH*, all versions), Modicon M340 CPU (part numbers BMXP34*, all versions), Modicon MC80 (part numbers BMKC80*, all versions), Modicon Momentum Ethernet CPU (part numbers 171CBU*, all versions), PLC Simulator for EcoStruxureª Control Expert, including all Unity Pro versions (former name of EcoStruxureª Control Expert, all versions), PLC Simulator for EcoStruxureª Process Expert including all HDCS versions (former name of EcoStruxureª Process Expert, all versions), Modicon Quantum CPU (part numbers 140CPU*, all versions), Modicon Premium CPU (part numbers TSXP5*, all versions).

Action-Not Available
Vendor-n/a
Product-modicon_m580_bmeh582040modicon_premium_tsxp57_454mmodicon_mc80_bmkc8030311modicon_quantum_140cpu65160modicon_momentum_171cbu98090modicon_premium_tsxp57_1634mmodicon_m580_bmeh582040smodicon_m340_bmxp342010modicon_m580_bmep583020modicon_m580_bmeh584040smodicon_m580_bmeh586040smodicon_m580_bmep586040modicon_mc80_bmkc8020310modicon_m580_bmeh586040modicon_m580_bmep584040modicon_m580_bmep582020modicon_premium_tsxp57_2634mmodicon_quantum_140cpu65160cmodicon_m340_bmxp341000plc_simulator_for_ecostruxure_process_expertmodicon_quantum_140cpu65150cmodicon_quantum_140cpu65150modicon_m580_bmep585040cmodicon_m580_bmep584040smodicon_m580_bmeh582040cmodicon_m580_bmep583040modicon_m580_bmep582040modicon_m580_bmep585040modicon_m580_bmeh584040modicon_premium_tsxp57_4634mmodicon_m580_bmep582040hmodicon_momentum_171cbu78090modicon_premium_tsxp57_5634mmodicon_premium_tsxp57_554mmodicon_m580_bmep584020modicon_mc80_bmkc8020301modicon_m340_bmxp342020modicon_m580_bmep582040smodicon_premium_tsxp57_2834mplc_simulator_for_ecostruxure_control_expertmodicon_m580_bmep581020modicon_m580_bmep586040cmodicon_m580_bmeh586040cmodicon_momentum_171cbu98091modicon_m580_bmep581020hmodicon_m580_bmep582020hmodicon_m580_bmeh584040cmodicon_m340_bmxp342030modicon_premium_tsxp57_6634mModicon M580 CPU (part numbers BMEP* and BMEH*, all versions), Modicon M340 CPU (part numbers BMXP34*, all versions), Modicon MC80 (part numbers BMKC80*, all versions), Modicon Momentum Ethernet CPU (part numbers 171CBU*, all versions), PLC Simulator for EcoStruxureª Control Expert, including all Unity Pro versions (former name of EcoStruxureª Control Expert, all versions), PLC Simulator for EcoStruxureª Process Expert including all HDCS versions (former name of EcoStruxureª Process Expert, all versions), Modicon Quantum CPU (part numbers 140CPU*, all versions), Modicon Premium CPU (part numbers TSXP5*, all versions)
CWE ID-CWE-476
NULL Pointer Dereference
CVE-2020-7537
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.39% / 59.17%
||
7 Day CHG~0.00%
Published-11 Dec, 2020 | 00:51
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium (see security notifications for affected versions), that could cause denial of service when a specially crafted Read Physical Memory request over Modbus is sent to the controller.

Action-Not Available
Vendor-n/a
Product-modicon_m580_bmep582040_firmwaretsxp575634_firmwaretsxp574634modicon_m580_bmep583040_firmwaremodicon_m340_bmxp3420102clmodicon_m340_bmxp3420302_firmwaremodicon_m580_bmep583020modicon_m580_bmep586040modicon_m580_bmep584040modicon_m340_bmxp342000modicon_m580_bmep582020modicon_m580_bmep583020_firmwaremodicon_m340_bmxp3420302cl_firmwaremodicon_m340_bmxp341000modicon_m340_bmxp342020_firmwaremodicon_m340_bmxp3420102_firmwaremodicon_m580_bmep585040_firmwaremodicon_m340_bmxp3420102cl_firmwaremodicon_m580_bmep584040_firmwaremodicon_m580_bmep583040tsxp574634_firmwaremodicon_m580_bmep582040modicon_m580_bmep585040modicon_m580_bmep584020_firmwaremodicon_m340_bmxp3420302clmodicon_m340_bmxp3420302modicon_m580_bmep584020modicon_m340_bmxp342020tsxp576634modicon_m340_bmxp341000_firmwaremodicon_m580_bmep581020_firmwaremodicon_m580_bmep581020modicon_m580_bmep582020_firmwaretsxp576634_firmwaremodicon_m340_bmxp342000_firmwaremodicon_m340_bmxp3420102tsxp575634modicon_m580_bmep586040_firmwareModicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium (see security notifications for affected versions)
CWE ID-CWE-754
Improper Check for Unusual or Exceptional Conditions
CVE-2020-7486
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.30% / 52.81%
||
7 Day CHG~0.00%
Published-15 Apr, 2020 | 21:03
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

**VERSION NOT SUPPORTED WHEN ASSIGNED** A vulnerability could cause TCM modules to reset when under high network load in TCM v10.4.x and in system v10.3.x. This vulnerability was discovered and remediated in version v10.5.x on August 13, 2009. TCMs from v10.5.x and on will no longer exhibit this behavior.

Action-Not Available
Vendor-n/a
Product-tricon_tcm_4352tricon_tcm_4352atricon_tcm_4351btricon_tcm_4351a_firmwaretricon_tcm_4351_firmwaretricon_tcm_4352btricon_tcm_4352b_firmwaretricon_tcm_4352_firmwaretricon_tcm_4351b_firmwaretricon_tcm_4351atricon_tcm_4352a_firmwaretricon_tcm_4351Tricon TCM Model 4351, 4352, 4351A/B, 4352A/B (v10.3.x, v10.4.x)
CWE ID-CWE-400
Uncontrolled Resource Consumption
CVE-2019-6811
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.39% / 59.17%
||
7 Day CHG~0.00%
Published-17 Sep, 2019 | 19:55
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An Improper Check for Unusual or Exceptional Conditions (CWE-754) vulnerability exists in Modicon Quantum 140 NOE771x1 version 6.9 and earlier, which could cause denial of service when the module receives an IP fragmented packet with a length greater than 65535 bytes. The module then requires a power cycle to recover.

Action-Not Available
Vendor-
Product-modicon_quantum_140noe77101modicon_quantum_140noe77111_firmwaremodicon_quantum_140noe77111modicon_quantum_140noe77101_firmwareModicon Quantum 140 NOE771x1
CWE ID-CWE-754
Improper Check for Unusual or Exceptional Conditions
CVE-2019-6807
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.14% / 34.83%
||
7 Day CHG~0.00%
Published-22 May, 2019 | 20:05
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible denial of service when writing sensitive application variables to the controller over Modbus.

Action-Not Available
Vendor-n/a
Product-modicon_quantummodicon_quantum_firmwaremodicon_m580_firmwaremodicon_premium_firmwaremodicon_premiummodicon_m340modicon_m340_firmwaremodicon_m580Modicon M580 Modicon M340 Modicon Quantum Modicon Premium
CWE ID-CWE-755
Improper Handling of Exceptional Conditions
CVE-2017-7965
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-7.3||HIGH
EPSS-0.08% / 25.11%
||
7 Day CHG~0.00%
Published-07 Jun, 2017 | 19:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A buffer overflow vulnerability exists in Programming Software executable AlTracePrint.exe, in Schneider Electric's SoMachine HVAC v2.1.0 for Modicon M171/M172 Controller.

Action-Not Available
Vendor-Schneider Electric SE
Product-somachine_hvacSoMachine HVAC Programming Software
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2013-3075
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-10||HIGH
EPSS-34.69% / 96.88%
||
7 Day CHG~0.00%
Published-19 Apr, 2013 | 10:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Multiple buffer overflows in ActUWzd.dll 1.0.0.1 in Mitsubishi MX Component 3, as distributed in Citect CitectFacilities 7.10 and CitectScada 7.10r1, allow remote attackers to execute arbitrary code via a long string, as demonstrated by a long WzTitle property value to a certain ActiveX control.

Action-Not Available
Vendor-n/aSchneider Electric SEMitsubishi Electric Automation, Inc.
Product-mitsubishi_mx_componentcitectscadacitectfacilitiesn/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2013-2761
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-4||MEDIUM
EPSS-0.54% / 66.58%
||
7 Day CHG~0.00%
Published-04 Apr, 2013 | 10:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The Schneider Electric M340 BMXNOE01xx and BMXP3420xx PLC modules allow remote authenticated users to cause a denial of service (module crash) via crafted FTP traffic, as demonstrated by the FileZilla FTP client.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-modicon_m340n/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2017-14024
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-3.53% / 87.18%
||
7 Day CHG~0.00%
Published-13 Nov, 2017 | 20:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Stack-based Buffer Overflow issue was discovered in Schneider Electric InduSoft Web Studio v8.0 SP2 Patch 1 and prior versions, and InTouch Machine Edition v8.0 SP2 Patch 1 and prior versions. The stack-based buffer overflow vulnerability has been identified, which may allow remote code execution with high privileges.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-wonderware_intouchwonderware_indusoft_web_studioSchneider Electric InduSoft Web Studio and InTouch Machine Edition
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2012-0929
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-12.55% / 93.69%
||
7 Day CHG~0.00%
Published-28 Jan, 2012 | 01:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Multiple buffer overflows in Schneider Electric Modicon Quantum PLC allow remote attackers to cause a denial of service via malformed requests to the (1) FTP server or (2) HTTP server.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-modicon_quantum_plcn/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2021-22709
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.70% / 71.06%
||
7 Day CHG~0.00%
Published-11 Mar, 2021 | 20:27
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in loss of data or remote code execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_systemInteractive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2011-3330
Matching Score-6
Assigner-CERT/CC
ShareView Details
Matching Score-6
Assigner-CERT/CC
CVSS Score-7.2||HIGH
EPSS-1.13% / 77.42%
||
7 Day CHG~0.00%
Published-04 Nov, 2011 | 21:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Buffer overflow in the UnitelWay Windows Device Driver, as used in Schneider Electric Unity Pro 6 and earlier, OPC Factory Server 3.34, Vijeo Citect 7.20 and earlier, Telemecanique Driver Pack 2.6 and earlier, Monitor Pro 7.6 and earlier, and PL7 Pro 4.5 and earlier, allows local users, and possibly remote attackers, to execute arbitrary code via an unspecified system parameter.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-telemecanique_driver_packunity_promonitor_propl7_provijeo_citectopc_factory_servern/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2021-22712
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.13% / 32.71%
||
7 Day CHG~0.00%
Published-11 Mar, 2021 | 20:25
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in arbitrary read or write conditions when malicious CGF (Configuration Group File) file is imported to IGSS Definition due to an unchecked pointer address.

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_systemInteractive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2021-22705
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.06% / 18.28%
||
7 Day CHG~0.00%
Published-26 May, 2021 | 19:19
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause denial of service or unauthorized access to system information when interacting directly with a driver installed by Vijeo Designer or EcoStruxure Machine Expert

Action-Not Available
Vendor-n/a
Product-harmony_gkvijeo_designerecostruxure_machine_expertharmony_stuharmony_gtuharmony_hmiscuharmony_gtoharmony_stoharmony_gtuxHarmony HMI Products Configured by Vijeo Designer (all versions prior to V6.2 SP11 ) or EcoStruxure Machine Expert (all versions prior to V2.0)
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2020-7554
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.66% / 70.21%
||
7 Day CHG~0.00%
Published-19 Nov, 2020 | 21:07
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_systemIGSS Definition (Def.exe) version 14.0.0.20247 and prior
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2021-22710
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.70% / 71.06%
||
7 Day CHG~0.00%
Published-11 Mar, 2021 | 20:26
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could cause remote code execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_systemInteractive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2018-7522
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-6.7||MEDIUM
EPSS-0.07% / 21.02%
||
7 Day CHG~0.00%
Published-04 May, 2018 | 17:00
Updated-17 Sep, 2024 | 00:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, when a system call is made, registers are stored to a fixed memory location. Modifying the data in this location could allow attackers to gain supervisor-level access and control system states.

Action-Not Available
Vendor-
Product-triconex_tricon_mp_3008triconex_tricon_mp_3008_firmwareTriconex Tricon
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2018-7796
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-6.3||MEDIUM
EPSS-0.28% / 51.39%
||
7 Day CHG~0.00%
Published-24 Dec, 2018 | 16:00
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Buffer Error vulnerability exists in PowerSuite 2, all released versions (VW3A8104 & Patches), which could cause an overflow in the memcpy function, leading to corruption of data and program instability.

Action-Not Available
Vendor-
Product-powersuite_2PowerSuite 2, All released versions (VW3A8104 & Patches)
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2016-8352
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-10||CRITICAL
EPSS-2.50% / 84.72%
||
7 Day CHG~0.00%
Published-13 Feb, 2017 | 21:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in Schneider Electric ConneXium firewalls TCSEFEC23F3F20 all versions, TCSEFEC23F3F21 all versions, TCSEFEC23FCF20 all versions, TCSEFEC23FCF21 all versions, and TCSEFEC2CF3F20 all versions. A stack-based buffer overflow can be triggered during the SNMP login authentication process that may allow an attacker to remotely execute code.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-connexium_firmwaretcsefec23f3f21tcsefec23fcf20tcsefec23f3f20tcsefec23fcf21tcsefec2cf3f20Schneider Electric ConneXium TCSEFEC2*
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2020-7550
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.66% / 70.21%
||
7 Day CHG~0.00%
Published-19 Nov, 2020 | 21:06
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 and prior that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_systemIGSS Definition (Def.exe) version 14.0.0.20247 and prior
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2020-28220
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-6.8||MEDIUM
EPSS-0.28% / 50.68%
||
7 Day CHG~0.00%
Published-11 Dec, 2020 | 00:51
Updated-04 Aug, 2024 | 16:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Modicon M258 Firmware (All versions prior to V5.0.4.11) and SoMachine/SoMachine Motion software (All versions), that could cause a buffer overflow when the length of a file transferred to the webserver is not verified.

Action-Not Available
Vendor-n/a
Product-modicon_m258_firmwaresomachine_motionsomachinemodicon_m258Modicon M258 Firmware (All versions prior to V5.0.4.11) and SoMachine/SoMachine Motion software (All versions)
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2015-7937
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-10||HIGH
EPSS-4.68% / 88.91%
||
7 Day CHG~0.00%
Published-21 Dec, 2015 | 11:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Stack-based buffer overflow in the GoAhead Web Server on Schneider Electric Modicon M340 PLC BMXNOx and BMXPx devices allows remote attackers to execute arbitrary code via a long password in HTTP Basic Authentication data.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-modicon_m340_bmxp342030bmxnoc0401modicon_m340_bmxp3420302bmxnoe0110hbmxnoe0110bmxpra0100bmxnoe0100modicon_m340_bmxp3420302hbmxnor0200modicon_m340_bmxp342020modicon_m340_bmxp342020hbmxnoe0100hbmxnor0200hn/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2015-8561
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-6.8||MEDIUM
EPSS-4.46% / 88.63%
||
7 Day CHG~0.00%
Published-15 Dec, 2015 | 02:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allows remote attackers to execute arbitrary code or cause a denial of service (memory corruption) via a crafted integer value to the (1) AttachToSS, (2) CopyAll, (3) CopyRange, (4) CopyRangeEx, or (5) SwapTable method, a different vulnerability than CVE-2015-7918.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-procliman/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2015-7918
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-6.8||MEDIUM
EPSS-12.86% / 93.77%
||
7 Day CHG~0.00%
Published-15 Dec, 2015 | 02:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Multiple buffer overflows in the F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allow remote attackers to execute arbitrary code via the (1) Attach, (2) DefinedName, (3) DefinedNameLocal, (4) ODBCPrepareEx, (5) ObjCreatePolygon, (6) SetTabbedTextEx, or (7) SetValidationRule method, a different vulnerability than CVE-2015-8561.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-procliman/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2018-8872
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.1||HIGH
EPSS-0.80% / 73.09%
||
7 Day CHG~0.00%
Published-04 May, 2018 | 17:00
Updated-16 Sep, 2024 | 16:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, system calls read directly from memory addresses within the control program area without any verification. Manipulating this data could allow attacker data to be copied anywhere within memory.

Action-Not Available
Vendor-
Product-triconex_tricon_mp_3008triconex_tricon_mp_3008_firmwareTriconex Tricon
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2018-7838
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.37% / 57.87%
||
7 Day CHG~0.00%
Published-15 Jul, 2019 | 20:49
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-119 Buffer Errors vulnerability exists in Modicon M580 CPU - BMEP582040, all versions before V2.90, and Modicon Ethernet Module BMENOC0301, all versions before V2.16, which could cause denial of service on the FTP service of the controller or the Ethernet BMENOC module when it receives a FTP CWD command with a data length greater than 1020 bytes. A power cycle is then needed to reactivate the FTP service.

Action-Not Available
Vendor-
Product-bmeh584040cmodicon_m580_bmep582040_firmwarebmeh582040_firmwarebmeh584040bmeh582040cmodicon_m580_bmep583040_firmwaremodicon_m580_bmep583020modicon_m580_bmep586040modicon_m580_bmep584040modicon_m580_bmep582020modicon_m580_bmep583020_firmwarebmeh586040_firmwaremodicon_m580_bmep585040_firmwaremodicon_m580_bmep584040_firmwaremodicon_m580_bmep585040cmodicon_m580_bmep584040smodicon_m580_bmep583040modicon_m580_bmep582040modicon_m580_bmep584020_firmwaremodicon_m580_bmep585040modicon_m580_bmep582040hbmeh586040modicon_m580_bmep584020modicon_m580_bmep582040s_firmwaremodicon_m580_bmep582040smodicon_m580_bmep581020_firmwaremodicon_m580_bmep581020modicon_m580_bmep586040cbmenoc0301_firmwarebmeh586040cmodicon_m580_bmep582020_firmwaremodicon_m580_bmep581020hmodicon_m580_bmep582020hbmeh582040bmenoc0301modicon_m580_bmep586040_firmwareModicon M580 CPU - BMEP582040 all versions before V2.90 and Modicon Ethernet Module BMENOC0301 all versions before V2.16
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2018-7780
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.54% / 66.73%
||
7 Day CHG~0.00%
Published-03 Jul, 2018 | 14:00
Updated-17 Sep, 2024 | 00:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, a buffer overflow vulnerability exist in cgi program "set".

Action-Not Available
Vendor-
Product-imp519-1er_firmwareimp319-1eribp319-1erimps110-1eibp519-1er_firmwareimp1110-1er_firmwareimps110-1eribp1110-1erimp519-1_firmwareimp519-1ibps110-1er_firmwareimp219-1_firmwareimp319-1_firmwareimps110-1er_firmwareimp219-1erimps110-1_firmwareibp319-1er_firmwareimp319-1er_firmwareimps110-1e_firmwareimp219-1e_firmwareimp219-1eibp219-1erimps110-1imp1110-1e_firmwareimp1110-1_firmwareimp519-1eimp319-1e_firmwareimp1110-1erimp219-1ibp219-1er_firmwareimp519-1erimp1110-1eimp319-1eibp1110-1er_firmwareibps110-1erimp219-1er_firmwareimp519-1e_firmwareimp1110-1ibp519-1erimp319-1Pelco Sarix Professional V1
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2018-7851
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-6.5||MEDIUM
EPSS-0.33% / 55.52%
||
7 Day CHG-0.02%
Published-22 May, 2019 | 19:56
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-119: Buffer errors vulnerability exists in Modicon M580 with firmware prior to V2.50, Modicon M340 with firmware prior to V3.01, BMxCRA312xx with firmware prior to V2.40, All firmware versions of Modicon Premium and 140CRA312xxx when sending a specially crafted Modbus packet, which could cause a denial of service to the device that would force a restart to restore availability.

Action-Not Available
Vendor-n/a
Product-bmeh584040cbmx\/e_cra_firmwarebmeh584040bmxcra31200bmeh582040c140cra312xxx_firmwaremodicon_premium_firmwaremodicon_m340_bmxp3420102clmodicon_m580_bmep583020bmxcra31210cmodicon_m580_bmep586040modicon_m580_bmep584040modicon_m340_bmxp342000modicon_m580_bmep582020modicon_m340_bmxp341000m340_firmwaremodicon_m340_bmxp3420302hmodicon_m580_bmep585040cmodicon_m580_bmep584040smodicon_m580_bmep583040modicon_m580_bmep582040modicon_m580_bmep585040modicon_m340_bmxp341000hmodicon_m580_bmep582040hmodicon_m340_bmxp3420302clbmeh586040modicon_m340_bmxp3420302modicon_premiummodicon_m580_bmep584020modicon_m580_bmep582040smodicon_m340_bmxp342020modicon_m340_bmxp342020hmodicon_m580_bmep581020modicon_m580_bmep586040cbmeh586040c140cra312xxxmodicon_m580_bmep581020hmodicon_m580_bmep582020hbmeh582040modicon_m340_bmxp3420102m580_firmwareModicon M580 with firmware prior to V2.50 Modicon M340 with firmware prior to V3.01 BMxCRA312xx with firmware prior to V2.40 All firmware versions of Modicon Premium and 140CRA312xxx
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2014-8511
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-10||HIGH
EPSS-5.35% / 89.69%
||
7 Day CHG~0.00%
Published-27 Dec, 2014 | 15:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Buffer overflow in an ActiveX control in Atx45.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8512. NOTE: this may be clarified later based on details provided by researchers.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-procliman/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2014-9200
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.5||HIGH
EPSS-1.47% / 80.11%
||
7 Day CHG~0.00%
Published-01 Feb, 2015 | 15:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Stack-based buffer overflow in an unspecified DLL file in a DTM development kit in Schneider Electric Unity Pro, SoMachine, SoMove, SoMove Lite, Modbus Communication Library 2.2.6 and earlier, CANopen Communication Library 1.0.2 and earlier, EtherNet/IP Communication Library 1.0.0 and earlier, EM X80 Gateway DTM (MB TCP/SL), Advantys DTM for OTB, Advantys DTM for STB, KINOS DTM, SOLO DTM, and Xantrex DTMs allows remote attackers to execute arbitrary code via unspecified vectors.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-unity_prosomovesomove_litesomachinen/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2014-9190
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-10||HIGH
EPSS-5.34% / 89.67%
||
7 Day CHG~0.00%
Published-10 Jan, 2015 | 02:00
Updated-24 Jul, 2025 | 22:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Schneider Electric Wonderware InTouch Access Anywhere Server Buffer Overflow

Stack-based buffer overflow in Schneider Electric Wonderware InTouch Access Anywhere Server 10.6 and 11.0 allows remote attackers to execute arbitrary code via a request for a filename that does not exist.

Action-Not Available
Vendor-Schneider Electric SE
Product-wonderware_intouch_access_anywhere_serverInTouch Access Anywhere Server
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2014-8390
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-4.4||MEDIUM
EPSS-0.16% / 37.70%
||
7 Day CHG-0.01%
Published-03 Apr, 2015 | 10:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Multiple buffer overflows in Schneider Electric VAMPSET before 2.2.168 allow local users to gain privileges via malformed disturbance-recording data in a (1) CFG or (2) DAT file.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-vampsetn/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2014-9206
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-6.9||MEDIUM
EPSS-0.05% / 13.58%
||
7 Day CHG~0.00%
Published-14 Mar, 2015 | 01:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Stack-based buffer overflow in Device Type Manager (DTM) 3.1.6 and earlier for Schneider Electric Invensys SRD Control Valve Positioner devices 960 and 991 allows local users to gain privileges via a malformed DLL file.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-device_type_managern/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2014-5407
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-4.4||MEDIUM
EPSS-0.05% / 15.65%
||
7 Day CHG~0.00%
Published-15 Sep, 2014 | 14:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Multiple stack-based buffer overflows in Schneider Electric VAMPSET 2.2.136 and earlier allow local users to cause a denial of service (application halt) via a malformed (1) setting file or (2) disturbance recording file.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-vampsetn/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2014-0789
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.8||HIGH
EPSS-0.52% / 65.60%
||
7 Day CHG~0.00%
Published-04 Apr, 2014 | 15:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Multiple buffer overflows in the OPC Automation 2.0 Server Object ActiveX control in Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 3.5 and earlier, TLXCDSTOFS33 3.5 and earlier, TLXCDLUOFS33 3.5 and earlier, TLXCDLTOFS33 3.5 and earlier, and TLXCDLFOFS33 3.5 and earlier allow remote attackers to cause a denial of service via long arguments to unspecified functions.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-opc_factory_server_tlxcdluofsopc_factory_server_tlxcdsuofsopc_factory_server_tlxcdlfofsopc_factory_server_tlxcdstofsopc_factory_server_tlxcdltofsn/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2014-0774
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-6.9||MEDIUM
EPSS-0.05% / 15.06%
||
7 Day CHG~0.00%
Published-28 Feb, 2014 | 02:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Stack-based buffer overflow in the C++ sample client in Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 - 3.35, TLXCDSTOFS33 - 3.35, TLXCDLUOFS33 - 3.35, TLXCDLTOFS33 - 3.35, and TLXCDLFOFS33 - 3.35 allows local users to gain privileges via vectors involving a malformed configuration file.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-ofs_test_client_tlxcdlfofs33opc_factory_serverofs_test_client_tlxcdltofs33ofs_test_client_tlxcdsuofs33ofs_test_client_tlxcdstofs33ofs_test_client_tlxcdluofs33n/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2022-37302
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-5.5||MEDIUM
EPSS-0.06% / 17.88%
||
7 Day CHG~0.00%
Published-13 Sep, 2022 | 09:35
Updated-03 Aug, 2024 | 10:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a crash of the Control Expert software when an incorrect project file is opened. Affected Products: EcoStruxure Control Expert(V15.1 HF001 and prior).

Action-Not Available
Vendor-
Product-ecostruxure_control_expertEcoStruxure Control Expert
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2013-0658
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-10||HIGH
EPSS-69.61% / 98.59%
||
7 Day CHG~0.00%
Published-15 Feb, 2013 | 11:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Heap-based buffer overflow in RFManagerService.exe in Schneider Electric Accutech Manager 2.00.1 and earlier allows remote attackers to execute arbitrary code via a crafted HTTP request.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-accutech_managern/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2013-0657
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-10||HIGH
EPSS-60.15% / 98.20%
||
7 Day CHG~0.00%
Published-21 Jan, 2013 | 16:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Stack-based buffer overflow in Schneider Electric Interactive Graphical SCADA System (IGSS) 10 and earlier allows remote attackers to execute arbitrary code by sending TCP port-12397 data that does not comply with a protocol.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-interactive_graphical_scada_systemn/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2017-9629
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-19.42% / 95.16%
||
7 Day CHG~0.00%
Published-07 Jul, 2017 | 17:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Stack-Based Buffer Overflow issue was discovered in Schneider Electric Wonderware ArchestrA Logger, versions 2017.426.2307.1 and prior. The stack-based buffer overflow vulnerability has been identified, which may allow a remote attacker to execute arbitrary code in the context of a highly privileged account.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-wonderware_archestra_loggerSchneider Electric Wonderware ArchestrA Logger
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
  • Previous
  • 1
  • 2
  • 3
  • 4
  • ...
  • 15
  • 16
  • Next
Details not found