A URL redirection vulnerability exists in Power Monitoring Expert, Energy Expert (formerly Power Manager) - EcoStruxure Power Monitoring Expert (PME) v8.2 (all editions), EcoStruxure Energy Expert 1.3 (formerly Power Manager), EcoStruxure Power SCADA Operation (PSO) 8.2 Advanced Reports and Dashboards Module, EcoStruxure Power Monitoring Expert (PME) v9.0, EcoStruxure Energy Expert v2.0, and EcoStruxure Power SCADA Operation (PSO) 9.0 Advanced Reports and Dashboards Module which could cause a phishing attack when redirected to a malicious site.
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 allowing an attacker to craft a URL containing JavaScript that will be executed within the user's browser, potentially impacting the machine the browser is running on.
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could enable SSH service due to lack of authentication for /login/bin/set_param could enable SSH service.
A CWE-79 Cross-Site Scripting vulnerability exists in all versions of the TSXETG100 allowing an attacker to send a specially crafted URL with an embedded script to a user that would then be executed within the context of that user.
In Schneider Electric U.motion Builder software versions prior to v1.3.4, a cross site scripting (XSS) vulnerability exists which could allow injection of malicious scripts.
Vulnerability in the Java SE, Java SE Embedded, JRockit component of Oracle Java SE (subcomponent: JMX). Supported versions that are affected are Java SE: 6u171, 7u161, 8u152 and 9.0.1; Java SE Embedded: 8u151; JRockit: R28.3.16. Difficult to exploit vulnerability allows unauthenticated attacker with network access via multiple protocols to compromise Java SE, Java SE Embedded, JRockit. Successful attacks of this vulnerability can result in unauthorized creation, deletion or modification access to critical data or all Java SE, Java SE Embedded, JRockit accessible data as well as unauthorized access to critical data or complete access to all Java SE, Java SE Embedded, JRockit accessible data. Note: This vulnerability can only be exploited by supplying data to APIs in the specified Component without using Untrusted Java Web Start applications or Untrusted Java applets, such as through a web service. CVSS 3.0 Base Score 7.4 (Confidentiality and Integrity impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N).
A cross-site request forgery vulnerability exists on the Secure Gateway component of Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 for multiple state-changing requests. This type of attack requires some level of social engineering in order to get a legitimate user to click on or access a malicious link/site containing the CSRF attack.
An issue was discovered in Schneider Electric homeLYnk Controller, LSS100100, all versions prior to V1.5.0. The homeLYnk controller is susceptible to a cross-site scripting attack. User inputs can be manipulated to cause execution of JavaScript code.
Cross-site scripting (XSS) vulnerability in the Schneider Electric PowerLogic PM8ECC module before 2.651 for PowerMeter 800 devices allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
A Path Traversal issue was discovered in Schneider Electric Pelco VideoXpert Enterprise all versions prior to 2.1. By sniffing communications, an unauthorized person can execute a directory traversal attack resulting in authentication bypass or session hijack.
A Cross Protocol Injection vulnerability exists in Schneider Electric's PowerLogic (PM5560 prior to FW version 2.5.4) product. The vulnerability makes the product susceptible to cross site scripting attack on its web browser. User inputs can be manipulated to cause execution of java script code.
A CWE-601 URL Redirection to Untrusted Site vulnerability exists that could cause an openredirect vulnerability leading to a cross site scripting attack. By providing a URL-encoded input attackers can cause the software’s web application to redirect to the chosen domain after a successful login is performed.
A CWE-601:URL Redirection to Untrusted Site (‘Open Redirect’) vulnerability exists that could cause disclosure of information through phishing attempts over HTTP.
A CWE-601: URL Redirection to Untrusted Site ('Open Redirect') vulnerability exists in Schneider Electric Software Update (SESU), V2.4.0 and prior, which could cause execution of malicious code on the victim's machine. In order to exploit this vulnerability, an attacker requires privileged access on the engineering workstation to modify a Windows registry key which would divert all traffic updates to go through a server in the attacker's possession. A man-in-the-middle attack is then used to complete the exploit.
In OAuth2 Proxy from version 5.1.1 and less than version 6.0.0, users can provide a redirect address for the proxy to send the authenticated user to at the end of the authentication flow. This is expected to be the original URL that the user was trying to access. This redirect URL is checked within the proxy and validated before redirecting the user to prevent malicious actors providing redirects to potentially harmful sites. This has been fixed in version 6.0.0.
Open redirect vulnerability in the SO Connect SO WIFI hotspot web interface, prior to version 140, allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks via a URL.
IBM Security Secret Server 10.6 could allow a remote attacker to conduct phishing attacks, using an open redirect attack. By persuading a victim to visit a specially crafted Web site, a remote attacker could exploit this vulnerability to spoof the URL displayed to redirect a user to a malicious Web site that would appear to be trusted. This could allow the attacker to obtain highly sensitive information or conduct further attacks against the victim. IBM X-Force ID: 190044.
A vulnerability was found in Netegrity SiteMinder up to 4.5.1 and classified as critical. Affected by this issue is the file /siteminderagent/pwcgi/smpwservicescgi.exe of the component Login. The manipulation of the argument target leads to an open redirect. The exploit has been disclosed to the public and may be used. NOTE: This vulnerability only affects products that are no longer supported by the maintainer
Microsoft Outlook Web Access (OWA), when used with Exchange, allows remote attackers to redirect users to arbitrary URLs for login via a link to the owalogon.asp application.
Unvalidated redirect vulnerability in in NetIQ eDirectory before 9.1.1 HF1.
The NetIQ Identity Manager user console, in versions prior to 4.7, is susceptible to URL redirection.
HPE XP P9000 Command View Advanced Edition Software (CVAE) has open URL redirection vulnerability in versions 7.0.0-00 to earlier than 8.60-00 of DevMgr, TSMgr and RepMgr.
vBulletin 3.x.x and 4.2.x through 4.2.5 has an open redirect via the redirector.php url parameter.
F-Secure Radar (on-premises) before 2018-02-15 has an Unvalidated Redirect via the ReturnUrl parameter that triggers upon a user login.
SimpleSAMLphp before 1.15.2 allows remote attackers to bypass an open redirect protection mechanism via crafted authority data in a URL.
Caddy v2.4 was discovered to contain an open redirect vulnerability. A remote unauthenticated attacker may exploit this vulnerability to redirect users to arbitrary web URLs by tricking the victim users to click on crafted links.
Gitpod before 0.6.0 allows unvalidated redirects.
On BIG-IP APM 11.6.0-11.6.3, an insecure AES ECB mode is used for orig_uri parameter in an undisclosed /vdesk link of APM virtual server configured with an access profile, allowing a malicious user to build a redirect URI value using different blocks of cipher texts.
NextAuth.js (next-auth) is am open source authentication solution for Next.js applications. Prior to versions 3.29.3 and 4.3.3, an open redirect vulnerability is present when the developer is implementing an OAuth 1 provider. Versions 3.29.3 and 4.3.3 contain a patch for this issue. The maintainers recommend adding a certain configuration to one's `callbacks` option as a workaround for those unable to upgrade.
IBM Maximo Asset Management 7.6.0 and 7.6.1 could allow a remote attacker to conduct phishing attacks, using a tabnabbing attack. By persuading a victim to visit a specially-crafted Web site, a remote attacker could exploit this vulnerability to redirect a user to a malicious Web site that would appear to be trusted. This could allow the attacker to obtain highly sensitive information or conduct further attacks against the victim. IBM X-Force ID: 179537.
In Nagios XI through 5.8.5, an open redirect vulnerability exists in the login function that could lead to spoofing.
In PrestaShop between versions 1.7.6.0 and 1.7.6.5, there is an open redirection when using back parameter. The impacts can be many, and vary from the theft of information and credentials to the redirection to malicious websites containing attacker-controlled content, which in some cases even cause XSS attacks. So even though an open redirection might sound harmless at first, the impacts of it can be severe should it be exploitable. The problem is fixed in 1.7.6.5
In nopCommerce 4.50.1, an open redirect vulnerability can be triggered by luring a user to authenticate to a nopCommerce page by clicking on a crafted link.
A PHP Local File inclusion vulnerability in the Redbasic theme for Hubzilla before version 7.2 allows remote attackers to include arbitrary php files via the schema parameter.
Open redirect vulnerability in objects/login.json.php in WWBN AVideo through 11.6, allows attackers to arbitrarily redirect users from a crafted url to the login page.
By linking to a specific url in Plone 2.5-5.1rc1 with a parameter, an attacker could send you to his own website. On its own this is not so bad: the attacker could more easily link directly to his own website instead. But in combination with another attack, you could be sent to the Plone login form and login, then get redirected to the specific url, and then get a second redirect to the attacker website. (The specific url can be seen by inspecting the hotfix code, but we don't want to make it too easy for attackers by spelling it out here.)
OAuth2 Proxy before 5.0 has an open redirect vulnerability. Authentication tokens could be silently harvested by an attacker. This has been patched in version 5.0.
The fix in Kibana for ESA-2017-23 was incomplete. With X-Pack security enabled, Kibana versions before 6.1.3 and 5.6.7 have an open redirect vulnerability on the login page that would enable an attacker to craft a link that redirects to an arbitrary website.
An issue was discovered in the web application in Cherwell Service Management (CSM) 10.2.3. It accepts and reflects arbitrary domains supplied via a client-controlled Host header. Injection of a malicious URL in the Host: header of the HTTP Request results in a 302 redirect to an attacker-controlled page.
Potential open redirection vulnerability when URL is crafted in specific format in NetIQ Access Manager prior to 5.0.2
Open redirect in hekto <=0.2.3 when target domain name is used as html filename on server.
The floragunn Search Guard plugin before 6.x-16 for Kibana allows URL injection for login redirects on the login page when basePath is set.
An open redirect was discovered in Symfony 2.7.x before 2.7.50, 2.8.x before 2.8.49, 3.x before 3.4.20, 4.0.x before 4.0.15, 4.1.x before 4.1.9 and 4.2.x before 4.2.1. By using backslashes in the `_failure_path` input field of login forms, an attacker can work around the redirection target restrictions and effectively redirect the user to any domain after login.
Express OpenID Connect is an Express JS middleware implementing sign on for Express web apps using OpenID Connect. Users of the `requiresAuth` middleware, either directly or through the default `authRequired` option, are vulnerable to an Open Redirect when the middleware is applied to a catch all route. If all routes under `example.com` are protected with the `requiresAuth` middleware, a visit to `http://example.com//google.com` will be redirected to `google.com` after login because the original url reported by the Express framework is not properly sanitized. This vulnerability affects versions prior to 2.7.2. Users are advised to upgrade. There are no known workarounds.
IBM Security Guardium Insights 2.0.1 could allow a remote attacker to conduct phishing attacks, using an open redirect attack. By persuading a victim to visit a specially crafted Web site, a remote attacker could exploit this vulnerability to spoof the URL displayed to redirect a user to a malicious Web site that would appear to be trusted. This could allow the attacker to obtain highly sensitive information or conduct further attacks against the victim. IBM X-Force ID: 184823.
next-auth v3 users before version 3.29.2 are impacted. next-auth version 4 users before version 4.3.2 are also impacted. Upgrading to 3.29.2 or 4.3.2 will patch this vulnerability. If you are not able to upgrade for any reason, you can add a configuration to your callbacks option. If you already have a `redirect` callback, make sure that you match the incoming `url` origin against the `baseUrl`.
Nextcloud Talk is a video and audio conferencing app for Nextcloud, a self-hosted productivity platform. Prior to versions 11.3.4, 12.2.2, and 13.0.0, when sharing a Deck card in conversation, the metaData can be manipulated so users can be tricked into opening arbitrary URLs. This issue is fixed in versions 11.3.4, 12.2.2, and 13.0.0. There are currently no known workarounds.
RSA Archer, versions prior to 6.7 P1 (6.7.0.1), contain a URL redirection vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability to redirect application users to arbitrary web URLs by tricking the victim users to click on maliciously crafted links. The vulnerability could be used to conduct phishing attacks that cause users to unknowingly visit malicious sites.
An issue was discovered in Oracle WebCenter Interaction Portal 10.3.3. The login function of the portal is vulnerable to insecure redirection (also called an open redirect). The in_hi_redirect parameter is not validated by the application after a successful login. NOTE: this CVE is assigned by MITRE and isn't validated by Oracle because Oracle WebCenter Interaction Portal is out of support.
An issue was discovered in BTITeam XBTIT. The "returnto" parameter of the login page is vulnerable to an open redirect due to a lack of validation. If a user is already logged in when accessing the page, they will be instantly redirected.