CVE-2023-5629

Summary
Assigner-schneider
Assigner Org ID-076d1eb6-cfab-4401-b34d-6dfc2a413bdb
Published At-14 Dec, 2023 | 04:42
Updated At-02 Aug, 2024 | 08:07
Rejected At-
Credits

A CWE-601:URL Redirection to Untrusted Site (‘Open Redirect’) vulnerability exists that could cause disclosure of information through phishing attempts over HTTP.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:schneider
Assigner Org ID:076d1eb6-cfab-4401-b34d-6dfc2a413bdb
Published At:14 Dec, 2023 | 04:42
Updated At:02 Aug, 2024 | 08:07
Rejected At:
▼CVE Numbering Authority (CNA)

A CWE-601:URL Redirection to Untrusted Site (‘Open Redirect’) vulnerability exists that could cause disclosure of information through phishing attempts over HTTP.

Affected Products
Vendor
Schneider Electric SESchneider Electric
Product
Trio Q-Series Ethernet Data Radio
Default Status
unaffected
Versions
Affected
  • Versions prior to 2.7.0
Vendor
Schneider Electric SESchneider Electric
Product
Trio E-Series Ethernet Data Radio
Default Status
unaffected
Versions
Affected
  • All versions of models ER45e, EB45e, EH45e
Vendor
Schneider Electric SESchneider Electric
Product
Trio J-Series Ethernet Data Radio
Default Status
unaffected
Versions
Affected
  • All Versions
Problem Types
TypeCWE IDDescription
CWECWE-601CWE-601 URL Redirection to Untrusted Site ('Open Redirect')
Type: CWE
CWE ID: CWE-601
Description: CWE-601 URL Redirection to Untrusted Site ('Open Redirect')
Metrics
VersionBase scoreBase severityVector
3.18.2HIGH
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:L/A:N
Version: 3.1
Base score: 8.2
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:L/A:N
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-346-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-346-01.pdf
N/A
Hyperlink: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-346-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-346-01.pdf
Resource: N/A
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-346-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-346-01.pdf
x_transferred
Hyperlink: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-346-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-346-01.pdf
Resource:
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cybersecurity@se.com
Published At:14 Dec, 2023 | 05:15
Updated At:27 Dec, 2023 | 18:45

A CWE-601:URL Redirection to Untrusted Site (‘Open Redirect’) vulnerability exists that could cause disclosure of information through phishing attempts over HTTP.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.16.1MEDIUM
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
Secondary3.18.2HIGH
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:L/A:N
Type: Primary
Version: 3.1
Base score: 6.1
Base severity: MEDIUM
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
Type: Secondary
Version: 3.1
Base score: 8.2
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:L/A:N
CPE Matches

Schneider Electric SE
schneider-electric
>>eb450>>-
cpe:2.3:h:schneider-electric:eb450:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>eb450_firmware>>-
cpe:2.3:o:schneider-electric:eb450_firmware:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>eb45e>>-
cpe:2.3:h:schneider-electric:eb45e:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>eb45e_firmware>>-
cpe:2.3:o:schneider-electric:eb45e_firmware:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>eh450>>-
cpe:2.3:h:schneider-electric:eh450:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>eh450_firmware>>-
cpe:2.3:o:schneider-electric:eh450_firmware:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>eh45e>>-
cpe:2.3:h:schneider-electric:eh45e:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>eh45e_firmware>>-
cpe:2.3:o:schneider-electric:eh45e_firmware:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>er450_firmware>>-
cpe:2.3:o:schneider-electric:er450_firmware:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>er450>>-
cpe:2.3:h:schneider-electric:er450:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>er45e_firmware>>-
cpe:2.3:o:schneider-electric:er45e_firmware:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>er45e>>-
cpe:2.3:h:schneider-electric:er45e:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>jr240_firmware>>-
cpe:2.3:o:schneider-electric:jr240_firmware:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>jr240>>-
cpe:2.3:h:schneider-electric:jr240:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>jr900_firmware>>-
cpe:2.3:o:schneider-electric:jr900_firmware:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>jr900>>-
cpe:2.3:h:schneider-electric:jr900:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>qr450_firmware>>Versions before 2.7.0(exclusive)
cpe:2.3:o:schneider-electric:qr450_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>qr450>>-
cpe:2.3:h:schneider-electric:qr450:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>qr150_firmware>>Versions before 2.7.0(exclusive)
cpe:2.3:o:schneider-electric:qr150_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>qr150>>-
cpe:2.3:h:schneider-electric:qr150:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>qb450_firmware>>Versions before 2.7.0(exclusive)
cpe:2.3:o:schneider-electric:qb450_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>qb450>>-
cpe:2.3:h:schneider-electric:qb450:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>qb150_firmware>>Versions before 2.7.0(exclusive)
cpe:2.3:o:schneider-electric:qb150_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>qb150>>-
cpe:2.3:h:schneider-electric:qb150:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>qp450_firmware>>Versions before 2.7.0(exclusive)
cpe:2.3:o:schneider-electric:qp450_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>qp450>>-
cpe:2.3:h:schneider-electric:qp450:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>qp150_firmware>>Versions before 2.7.0(exclusive)
cpe:2.3:o:schneider-electric:qp150_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>qp150>>-
cpe:2.3:h:schneider-electric:qp150:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>qh450_firmware>>Versions before 2.7.0(exclusive)
cpe:2.3:o:schneider-electric:qh450_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>qh450>>-
cpe:2.3:h:schneider-electric:qh450:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>qh150_firmware>>Versions before 2.7.0(exclusive)
cpe:2.3:o:schneider-electric:qh150_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>qh150>>-
cpe:2.3:h:schneider-electric:qh150:-:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-601Primarycybersecurity@se.com
CWE ID: CWE-601
Type: Primary
Source: cybersecurity@se.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-346-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-346-01.pdfcybersecurity@se.com
Vendor Advisory
Hyperlink: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-346-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-346-01.pdf
Source: cybersecurity@se.com
Resource:
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

740Records found

CVE-2023-5986
Matching Score-10
Assigner-Schneider Electric
ShareView Details
Matching Score-10
Assigner-Schneider Electric
CVSS Score-8.2||HIGH
EPSS-0.17% / 38.73%
||
7 Day CHG~0.00%
Published-15 Nov, 2023 | 03:47
Updated-02 Dec, 2024 | 21:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-601 URL Redirection to Untrusted Site vulnerability exists that could cause an openredirect vulnerability leading to a cross site scripting attack. By providing a URL-encoded input attackers can cause the software’s web application to redirect to the chosen domain after a successful login is performed.

Action-Not Available
Vendor-
Product-ecostruxure_power_monitoring_expertEcoStruxure Power Monitoring Expert (PME)EcoStruxure Power Operation (EPO) – Advanced Reporting and Dashboards ModuleEcoStruxure Power SCADA Operation (PSO) - Advanced Reporting and Dashboards Module
CWE ID-CWE-601
URL Redirection to Untrusted Site ('Open Redirect')
CVE-2023-5987
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-6.1||MEDIUM
EPSS-0.12% / 31.21%
||
7 Day CHG~0.00%
Published-15 Nov, 2023 | 03:48
Updated-02 Aug, 2024 | 08:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting) vulnerability that could cause a vulnerability leading to a cross site scripting condition where attackers can have a victim’s browser run arbitrary JavaScript when they visit a page containing the injected payload.

Action-Not Available
Vendor-
Product-ecostruxure_power_monitoring_expertEcoStruxure Power Monitoring Expert (PME)EcoStruxure Power Operation (EPO) – Advanced Reporting and Dashboards ModuleEcoStruxure Power SCADA Operation (PSO) - Advanced Reporting and Dashboards Module
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2021-22706
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-6.1||MEDIUM
EPSS-0.29% / 51.58%
||
7 Day CHG~0.00%
Published-21 Jul, 2021 | 10:41
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to impersonate the user who manages the charging station or carry out actions on their behalf when crafted malicious parameters are submitted to the charging station web server.

Action-Not Available
Vendor-n/a
Product-evlink_city_evc1s22p4evlink_parking_evf2evlink_parking_evf2_firmwareevlink_parking_ev.2_firmwareevlink_parking_evw2evlink_city_evc1s22p4_firmwareevlink_city_evc1s7p4_firmwareevlink_smart_wallbox_evb1a_firmwareevlink_smart_wallbox_evb1aevlink_parking_evw2_firmwareevlink_parking_ev.2evlink_city_evc1s7p4EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 )
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2021-22813
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-6.1||MEDIUM
EPSS-0.49% / 65.04%
||
7 Day CHG-0.32%
Published-28 Jan, 2022 | 19:09
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to an edit policy file. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)

Action-Not Available
Vendor-n/a
Product-single-phase_symmetragalaxy_g9kchupdpm138h-5upd60f6fk1pdpm277hpd40e5ek20-mpd40l6fk1-msymmetra_px_20galaxy_gvmsapd60g6fk1gutor_gvxgalaxy_3500network_management_card_2_firmwarepdpm150g6fpdrppnx10pdpb150g6fpmm500-alaxgutor_sxwpdpm150l6fpdpm175g6hapc_rack_power_distribution_unitspd60l6fk1pdpm288g6hnetwork_management_card_3pdpm138h-rpdrppnx10mpd40f6fk1-mrack_automatic_transfer_switchessmart-upspd40h5ek20-mnetwork_management_card_2symmetra_px_160pmm400-alaxsymmetra_px_40symmetra_px_48netbotz_nbrk0250pmm400-alagalaxy_g7xnetwork_management_card_3_firmwarepdpm144fpmm400-cubgalaxy_gfcgalaxy_rpp_grppip2x84ap9922_battery_management_systemsymmetra_px_100symmetra_px_500galaxy_gcxsagalaxy_gvxtssymmetra_px_250symmetra_px_96pmm500-cubpd40g6fk1-mgalaxy_gvmtspmm500-alapdpm72f-5un/a
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2012-0930
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-6.1||MEDIUM
EPSS-1.05% / 77.21%
||
7 Day CHG~0.00%
Published-28 Jan, 2012 | 01:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Cross-site scripting (XSS) vulnerability in Schneider Electric Modicon Quantum PLC allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-modicon_quantum_plcn/a
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2022-22812
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-6.1||MEDIUM
EPSS-0.53% / 66.48%
||
7 Day CHG~0.00%
Published-09 Feb, 2022 | 22:05
Updated-03 Aug, 2024 | 03:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause a web session compromise when an attacker injects and then executes arbitrary malicious JavaScript code inside the target browser. Affected Product: spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior)

Action-Not Available
Vendor-n/a
Product-fellerlynkwiser_for_knxspacelynkwiser_for_knx_firmwarefellerlynk_firmwarespacelynk_firmwarespaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior)
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2024-2050
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.2||HIGH
EPSS-0.10% / 26.91%
||
7 Day CHG~0.00%
Published-18 Mar, 2024 | 16:04
Updated-01 Aug, 2024 | 19:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-79: Improper Neutralization of Input During Web Page Generation (‘Cross-site Scripting’) vulnerability exists when an attacker injects then executes arbitrary malicious JavaScript code within the context of the product.

Action-Not Available
Vendor-
Product-Easergy T200 (Modbus) Models: T200I, T200E, T200P, T200S, T200H Easergy T200 (IEC104) Models: T200I, T200E, T200P, T200S, T200HEasergy T200 (DNP3) Models: T200I, T200E, T200P, T200S, T200H
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2023-25551
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-6.1||MEDIUM
EPSS-0.35% / 56.62%
||
7 Day CHG~0.00%
Published-18 Apr, 2023 | 20:37
Updated-12 Feb, 2025 | 16:01
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists on a DCE file upload endpoint when tampering with parameters over HTTP. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)

Action-Not Available
Vendor-Schneider Electric SE
Product-struxureware_data_center_expertStruxureWare Data Center Expert
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2022-43376
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.6||HIGH
EPSS-0.39% / 59.23%
||
7 Day CHG~0.00%
Published-18 Apr, 2023 | 19:55
Updated-05 Feb, 2025 | 20:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause code and session manipulation when malicious code is inserted into the browser. Affected Products: NetBotz 4 - 355/450/455/550/570 (V4.7.0 and prior)

Action-Not Available
Vendor-Schneider Electric SE
Product-netbotz_570_firmwarenetbotz_355netbotz_455_firmwarenetbotz_550netbotz_570netbotz_450netbotz_455netbotz_550_firmwarenetbotz_355_firmwarenetbotz_450_firmwareNetBotz 4 - 355/450/455/550/570
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2019-6853
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-6.1||MEDIUM
EPSS-0.36% / 57.57%
||
7 Day CHG~0.00%
Published-20 Nov, 2019 | 22:01
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-79: Failure to Preserve Web Page Structure vulnerability exists in Andover Continuum (models 9680, 5740 and 5720, bCX4040, bCX9640, 9900, 9940, 9924 and 9702) , which could enable a successful Cross-site Scripting (XSS attack) when using the products web server.

Action-Not Available
Vendor-
Product-andover_continuum_9941_firmwareandover_continuum_5720_firmwareandover_continuum_9924andover_continuum_9900_firmwareandover_continuum_5740_firmwareandover_continuum_9940andover_continuum_bcx9640andover_continuum_9702andover_continuum_9900andover_continuum_9924_firmwareandover_continuum_9680andover_continuum_9702_firmwareandover_continuum_9941andover_continuum_bcx9640_firmwareandover_continuum_9940_firmwareandover_continuum_5740andover_continuum_9200_firmwareandover_continuum_bcx4040_firmwareandover_continuum_bcx4040andover_continuum_9200andover_continuum_9680_firmwareandover_continuum_5720Andover Continuum models 9680, 5740 and 5720, bCX4040, bCX9640, 9900, 9940, 9924 and 9702
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2021-22814
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-6.1||MEDIUM
EPSS-0.49% / 65.04%
||
7 Day CHG-0.32%
Published-28 Jan, 2022 | 19:09
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists which could cause arbritrary script execution when a malicious file is read and displayed. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)

Action-Not Available
Vendor-n/a
Product-single-phase_symmetragalaxy_g9kchupdpm138h-5upd60f6fk1pdpm277hpd40e5ek20-mpd40l6fk1-msymmetra_px_20galaxy_gvmsapd60g6fk1gutor_gvxgalaxy_3500network_management_card_2_firmwarepdpm150g6fpdrppnx10pdpb150g6fpmm500-alaxgutor_sxwpdpm150l6fpdpm175g6hapc_rack_power_distribution_unitspd60l6fk1pdpm288g6hnetwork_management_card_3pdpm138h-rpdrppnx10mpd40f6fk1-mrack_automatic_transfer_switchessmart-upspd40h5ek20-mnetwork_management_card_2symmetra_px_160pmm400-alaxsymmetra_px_40symmetra_px_48netbotz_nbrk0250pmm400-alagalaxy_g7xnetwork_management_card_3_firmwarepdpm144fpmm400-cubgalaxy_gfcgalaxy_rpp_grppip2x84ap9922_battery_management_systemsymmetra_px_100symmetra_px_500galaxy_gcxsagalaxy_gvxtssymmetra_px_250symmetra_px_96pmm500-cubpd40g6fk1-mgalaxy_gvmtspmm500-alapdpm72f-5un/a
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2021-22811
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-6.1||MEDIUM
EPSS-0.49% / 65.04%
||
7 Day CHG-0.32%
Published-28 Jan, 2022 | 19:09
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause script execution when the request of a privileged account accessing the vulnerable web page is intercepted. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)

Action-Not Available
Vendor-n/a
Product-single-phase_symmetragalaxy_g9kchupdpm138h-5upd60f6fk1pdpm277hpd40e5ek20-mpd40l6fk1-msymmetra_px_20galaxy_gvmsapd60g6fk1gutor_gvxgalaxy_3500network_management_card_2_firmwarepdpm150g6fpdrppnx10pdpb150g6fpmm500-alaxgutor_sxwpdpm150l6fpdpm175g6hapc_rack_power_distribution_unitspd60l6fk1pdpm288g6hnetwork_management_card_3pdpm138h-rpdrppnx10mpd40f6fk1-mrack_automatic_transfer_switchessmart-upspd40h5ek20-mnetwork_management_card_2symmetra_px_160pmm400-alaxsymmetra_px_40symmetra_px_48netbotz_nbrk0250pmm400-alagalaxy_g7xnetwork_management_card_3_firmwarepdpm144fpmm400-cubgalaxy_gfcgalaxy_rpp_grppip2x84ap9922_battery_management_systemsymmetra_px_100symmetra_px_500galaxy_gcxsagalaxy_gvxtssymmetra_px_250symmetra_px_96pmm500-cubpd40g6fk1-mgalaxy_gvmtspmm500-alapdpm72f-5un/a
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2021-22723
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-6.1||MEDIUM
EPSS-0.32% / 54.30%
||
7 Day CHG~0.00%
Published-21 Jul, 2021 | 10:43
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-79: Improper Neutralization of Input During Web Page Generation (Cross-siteScripting) through Cross-Site Request Forgery (CSRF) vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to impersonate the user who manages the charging station or carry out actions on their behalf when crafted malicious parameters are submitted to the charging station web server.

Action-Not Available
Vendor-n/a
Product-evlink_city_evc1s22p4evlink_parking_evf2evlink_parking_evf2_firmwareevlink_parking_ev.2_firmwareevlink_parking_evw2evlink_city_evc1s22p4_firmwareevlink_city_evc1s7p4_firmwareevlink_smart_wallbox_evb1a_firmwareevlink_smart_wallbox_evb1aevlink_parking_evw2_firmwareevlink_parking_ev.2evlink_city_evc1s7p4EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 )
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2021-22822
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-6.1||MEDIUM
EPSS-0.32% / 54.30%
||
7 Day CHG-0.21%
Published-28 Jan, 2022 | 19:09
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-79 Improper Neutralization of Input During Web Page Generation (�Cross-site Scripting�) vulnerability exists that could allow an attacker to impersonate the user who manages the charging station or carry out actions on their behalf when crafted malicious parameters are submitted to the charging station web server. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2)

Action-Not Available
Vendor-n/a
Product-evlink_city_evc1s22p4evlink_parking_evf2evlink_parking_evp2pe_firmwareevlink_parking_evf2_firmwareevlink_parking_evw2evlink_parking_evp2peevlink_city_evc1s22p4_firmwareevlink_city_evc1s7p4_firmwareevlink_smart_wallbox_evb1a_firmwareevlink_smart_wallbox_evb1aevlink_parking_evw2_firmwareevlink_city_evc1s7p4n/a
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2021-22810
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-6.1||MEDIUM
EPSS-0.49% / 65.04%
||
7 Day CHG-0.32%
Published-28 Jan, 2022 | 19:09
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to a delete policy file. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)

Action-Not Available
Vendor-n/a
Product-single-phase_symmetragalaxy_g9kchupdpm138h-5upd60f6fk1pdpm277hpd40e5ek20-mpd40l6fk1-msymmetra_px_20galaxy_gvmsapd60g6fk1gutor_gvxgalaxy_3500network_management_card_2_firmwarepdpm150g6fpdrppnx10pdpb150g6fpmm500-alaxgutor_sxwpdpm150l6fpdpm175g6hapc_rack_power_distribution_unitspd60l6fk1pdpm288g6hnetwork_management_card_3pdpm138h-rpdrppnx10mpd40f6fk1-mrack_automatic_transfer_switchessmart-upspd40h5ek20-mnetwork_management_card_2symmetra_px_160pmm400-alaxsymmetra_px_40symmetra_px_48netbotz_nbrk0250pmm400-alagalaxy_g7xnetwork_management_card_3_firmwarepdpm144fpmm400-cubgalaxy_gfcgalaxy_rpp_grppip2x84ap9922_battery_management_systemsymmetra_px_100symmetra_px_500galaxy_gcxsagalaxy_gvxtssymmetra_px_250symmetra_px_96pmm500-cubpd40g6fk1-mgalaxy_gvmtspmm500-alapdpm72f-5un/a
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2021-22812
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-6.1||MEDIUM
EPSS-0.49% / 65.04%
||
7 Day CHG-0.32%
Published-28 Jan, 2022 | 19:09
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)

Action-Not Available
Vendor-n/a
Product-single-phase_symmetragalaxy_g9kchupdpm138h-5upd60f6fk1pdpm277hpd40e5ek20-mpd40l6fk1-msymmetra_px_20galaxy_gvmsapd60g6fk1gutor_gvxgalaxy_3500network_management_card_2_firmwarepdpm150g6fpdrppnx10pdpb150g6fpmm500-alaxgutor_sxwpdpm150l6fpdpm175g6hapc_rack_power_distribution_unitspd60l6fk1pdpm288g6hnetwork_management_card_3pdpm138h-rpdrppnx10mpd40f6fk1-mrack_automatic_transfer_switchessmart-upspd40h5ek20-mnetwork_management_card_2symmetra_px_160pmm400-alaxsymmetra_px_40symmetra_px_48netbotz_nbrk0250pmm400-alagalaxy_g7xnetwork_management_card_3_firmwarepdpm144fpmm400-cubgalaxy_gfcgalaxy_rpp_grppip2x84ap9922_battery_management_systemsymmetra_px_100symmetra_px_500galaxy_gcxsagalaxy_gvxtssymmetra_px_250symmetra_px_96pmm500-cubpd40g6fk1-mgalaxy_gvmtspmm500-alapdpm72f-5un/a
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2023-25553
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-6.1||MEDIUM
EPSS-0.42% / 61.20%
||
7 Day CHG~0.00%
Published-18 Apr, 2023 | 20:38
Updated-05 Feb, 2025 | 21:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists on a DCE endpoint through the logging capabilities of the webserver. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)

Action-Not Available
Vendor-Schneider Electric SE
Product-struxureware_data_center_expertStruxureWare Data Center Expert
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2020-7482
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-6.1||MEDIUM
EPSS-0.32% / 54.30%
||
7 Day CHG~0.00%
Published-23 Mar, 2020 | 19:23
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-79:Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists Andover Continuum (All versions), which could cause a Reflective Cross-site Scripting (XSS attack) when using the products' web server.

Action-Not Available
Vendor-n/a
Product-andover_continuum_9941_firmwareandover_continuum_5720_firmwareandover_continuum_9924andover_continuum_9900_firmwareandover_continuum_5740_firmwareandover_continuum_9940andover_continuum_bcx9640andover_continuum_9702andover_continuum_9900andover_continuum_9924_firmwareandover_continuum_9680andover_continuum_9702_firmwareandover_continuum_9941andover_continuum_bcx9640_firmwareandover_continuum_9940_firmwareandover_continuum_5740andover_continuum_9200_firmwareandover_continuum_bcx4040_firmwareandover_continuum_bcx4040andover_continuum_9200andover_continuum_9680_firmwareandover_continuum_5720Andover Continuum (All versions)
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2020-7481
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-6.1||MEDIUM
EPSS-0.32% / 54.30%
||
7 Day CHG~0.00%
Published-23 Mar, 2020 | 19:23
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-79:Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists Andover Continuum (All versions), which could enable a successful Cross-site Scripting (XSS attack) when using the products' web server.

Action-Not Available
Vendor-n/a
Product-andover_continuum_9941_firmwareandover_continuum_5720_firmwareandover_continuum_9924andover_continuum_9900_firmwareandover_continuum_5740_firmwareandover_continuum_9940andover_continuum_bcx9640andover_continuum_9702andover_continuum_9900andover_continuum_9924_firmwareandover_continuum_9680andover_continuum_9702_firmwareandover_continuum_9941andover_continuum_bcx9640_firmwareandover_continuum_9940_firmwareandover_continuum_5740andover_continuum_9200_firmwareandover_continuum_bcx4040_firmwareandover_continuum_bcx4040andover_continuum_9200andover_continuum_9680_firmwareandover_continuum_5720Andover Continuum (All versions)
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2020-28210
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-6.1||MEDIUM
EPSS-0.37% / 58.50%
||
7 Day CHG~0.00%
Published-19 Nov, 2020 | 21:01
Updated-04 Aug, 2024 | 16:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting) vulnerability exists in EcoStruxure Building Operation WebStation V2.0 - V3.1 that could cause an attacker to inject HTML and JavaScript code into the user's browser.

Action-Not Available
Vendor-n/a
Product-ecostruxure_building_operationEcoStruxure Building Operation WebStation V2.0 - V3.1
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2024-6528
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-5.4||MEDIUM
EPSS-0.57% / 68.00%
||
7 Day CHG~0.00%
Published-11 Jul, 2024 | 09:03
Updated-01 Aug, 2024 | 21:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause a vulnerability leading to a cross-site scripting condition where attackers can have a victim’s browser run arbitrary JavaScript when they visit a page containing the injected payload.

Action-Not Available
Vendor-
Product-modicon_m241_firmwaremodicon_m262_firmwaremodicon_m262modicon_lmc058modicon_m241modicon_m258modicon_m258_firmwaremodicon_lmc058_firmwaremodicon_m251_firmwaremodicon_m251Modicon Controllers M262Modicon Controllers M241 / M251Modicon Controllers M258 / LMC058
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2020-7520
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-4.7||MEDIUM
EPSS-0.33% / 55.00%
||
7 Day CHG~0.00%
Published-23 Jul, 2020 | 20:46
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-601: URL Redirection to Untrusted Site ('Open Redirect') vulnerability exists in Schneider Electric Software Update (SESU), V2.4.0 and prior, which could cause execution of malicious code on the victim's machine. In order to exploit this vulnerability, an attacker requires privileged access on the engineering workstation to modify a Windows registry key which would divert all traffic updates to go through a server in the attacker's possession. A man-in-the-middle attack is then used to complete the exploit.

Action-Not Available
Vendor-n/a
Product-software_update_utilitySchneider Electric Software Update (SESU) V2.4.0 and prior.
CWE ID-CWE-601
URL Redirection to Untrusted Site ('Open Redirect')
CVE-2018-7797
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-6.1||MEDIUM
EPSS-0.17% / 38.66%
||
7 Day CHG~0.00%
Published-17 Dec, 2018 | 22:00
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A URL redirection vulnerability exists in Power Monitoring Expert, Energy Expert (formerly Power Manager) - EcoStruxure Power Monitoring Expert (PME) v8.2 (all editions), EcoStruxure Energy Expert 1.3 (formerly Power Manager), EcoStruxure Power SCADA Operation (PSO) 8.2 Advanced Reports and Dashboards Module, EcoStruxure Power Monitoring Expert (PME) v9.0, EcoStruxure Energy Expert v2.0, and EcoStruxure Power SCADA Operation (PSO) 9.0 Advanced Reports and Dashboards Module which could cause a phishing attack when redirected to a malicious site.

Action-Not Available
Vendor-
Product-ecostruxure_energy_expertecostruxure_power_monitoring_expertecostruxure_power_scada_operationPower Monitoring Expert, Energy Expert (formerly Power Manager) - EcoStruxureª Power Monitoring Expert (PME) v8.2 (all editions), EcoStruxureª Energy Expert 1.3 (formerly Power Manager), EcoStruxureª Power SCADA Operation (PSO) 8.2 Advanced Reports and Dashboards Module, EcoStruxureª Power Monitoring Expert (PME) v9.0, EcoStruxureª Energy Expert v2.0, and EcoStruxureªPower SCADA Operation (PSO) 9.0 Advanced Reports and Dashboards Module
CWE ID-CWE-601
URL Redirection to Untrusted Site ('Open Redirect')
CVE-2018-7804
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-6.1||MEDIUM
EPSS-0.20% / 41.54%
||
7 Day CHG~0.00%
Published-17 Dec, 2018 | 22:00
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A URL Redirection to Untrusted Site vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 where a user clicking on a specially crafted link can be redirected to a URL of the attacker's choosing.

Action-Not Available
Vendor-
Product-modicom_bmxnor0200hmodicom_quantum_firmwaremodicom_premiummodicom_bmxnor0200h_firmwaremodicom_m340_firmwaremodicom_m340modicom_quantummodicom_premium_firmwareEmbedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200
CWE ID-CWE-601
URL Redirection to Untrusted Site ('Open Redirect')
CVE-2025-1300
Matching Score-4
Assigner-Ericsson
ShareView Details
Matching Score-4
Assigner-Ericsson
CVSS Score-6.1||MEDIUM
EPSS-0.10% / 27.09%
||
7 Day CHG~0.00%
Published-28 Feb, 2025 | 12:47
Updated-14 Nov, 2025 | 15:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Open redirect in CodeChecker web server

CodeChecker is an analyzer tooling, defect database and viewer extension for the Clang Static Analyzer and Clang Tidy. The CodeChecker web server contains an open redirect vulnerability due to missing protections against multiple slashes after the product name in the URL. This results in bypassing the protections against CVE-2021-28861, leading to the same open redirect pathway. This issue affects CodeChecker: through 6.24.5.

Action-Not Available
Vendor-Ericsson
Product-codecheckerCodeChecker
CWE ID-CWE-601
URL Redirection to Untrusted Site ('Open Redirect')
CVE-2021-32645
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-4.3||MEDIUM
EPSS-0.29% / 51.59%
||
7 Day CHG~0.00%
Published-27 May, 2021 | 16:50
Updated-03 Aug, 2024 | 23:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Open Redirect in tenancy

Tenancy multi-tenant is an open source multi-domain controller for the Laravel web framework. In some situations, it is possible to have open redirects where users can be redirected from your site to any other site using a specially crafted URL. This is only the case for installations where the default Hostname Identification is used and the environment uses tenants that have `force_https` set to `true` (default: `false`). Version 5.7.2 contains the relevant patches to fix this bug. Stripping the URL from special characters to prevent specially crafted URL's from being redirected to. As a work around users can set the `force_https` to every tenant to `false`, however this may degrade connection security.

Action-Not Available
Vendor-tenancytenancy
Product-multi-tenantmulti-tenant
CWE ID-CWE-601
URL Redirection to Untrusted Site ('Open Redirect')
CVE-2021-32478
Matching Score-4
Assigner-Red Hat, Inc.
ShareView Details
Matching Score-4
Assigner-Red Hat, Inc.
CVSS Score-6.1||MEDIUM
EPSS-3.75% / 87.75%
||
7 Day CHG~0.00%
Published-11 Mar, 2022 | 00:00
Updated-03 Aug, 2024 | 23:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The redirect URI in the LTI authorization endpoint required extra sanitizing to prevent reflected XSS and open redirect risks. Moodle versions 3.10 to 3.10.3, 3.9 to 3.9.6, 3.8 to 3.8.8 and earlier unsupported versions are affected.

Action-Not Available
Vendor-n/aMoodle Pty Ltd
Product-moodlemoodle
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CWE ID-CWE-601
URL Redirection to Untrusted Site ('Open Redirect')
CVE-2018-25091
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.1||MEDIUM
EPSS-0.25% / 48.05%
||
7 Day CHG~0.00%
Published-15 Oct, 2023 | 00:00
Updated-16 Sep, 2024 | 19:01
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

urllib3 before 1.24.2 does not remove the authorization HTTP header when following a cross-origin redirect (i.e., a redirect that differs in host, port, or scheme). This can allow for credentials in the authorization header to be exposed to unintended hosts or transmitted in cleartext. NOTE: this issue exists because of an incomplete fix for CVE-2018-20060 (which was case-sensitive).

Action-Not Available
Vendor-n/aPython Software Foundation
Product-urllib3n/a
CWE ID-CWE-601
URL Redirection to Untrusted Site ('Open Redirect')
CVE-2022-36029
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-9.1||CRITICAL
EPSS-0.07% / 22.46%
||
7 Day CHG~0.00%
Published-25 Apr, 2024 | 20:42
Updated-24 Apr, 2025 | 13:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
BigBlueButton Greenlight Open Redirect vulnerability

Greenlight is an end-user interface for BigBlueButton servers. Versions prior to 2.13.0 have an open redirect vulnerability in the Login page due to unchecked the value of the `return_to` cookie. Versions 2.13.0 contains a patch for the issue.

Action-Not Available
Vendor-bigbluebuttonbigbluebuttonbigbluebutton
Product-greenlightgreenlightgreenlight
CWE ID-CWE-601
URL Redirection to Untrusted Site ('Open Redirect')
CVE-2021-32956
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-6.1||MEDIUM
EPSS-0.16% / 36.51%
||
7 Day CHG~0.00%
Published-18 Jun, 2021 | 13:52
Updated-03 Aug, 2024 | 23:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Advantech WebAccess/SCADA Versions 9.0.1 and prior is vulnerable to redirection, which may allow an attacker to send a maliciously crafted URL that could result in redirecting a user to a malicious webpage.

Action-Not Available
Vendor-n/aAdvantech (Advantech Co., Ltd.)
Product-webaccess\/scadaAdvantech WebAccess/SCADA
CWE ID-CWE-601
URL Redirection to Untrusted Site ('Open Redirect')
CVE-2021-32805
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-7.2||HIGH
EPSS-0.19% / 40.66%
||
7 Day CHG~0.00%
Published-08 Sep, 2021 | 17:45
Updated-07 Mar, 2025 | 14:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
URL Redirection to Untrusted Site ('Open Redirect') in Flask-AppBuilder

Flask-AppBuilder is an application development framework, built on top of Flask. In affected versions if using Flask-AppBuilder OAuth, an attacker can share a carefully crafted URL with a trusted domain for an application built with Flask-AppBuilder, this URL can redirect a user to a malicious site. This is an open redirect vulnerability. To resolve this issue upgrade to Flask-AppBuilder 3.2.2 or above. If upgrading is infeasible users may filter HTTP traffic containing `?next={next-site}` where the `next-site` domain is different from the application you are protecting as a workaround.

Action-Not Available
Vendor-dpgaspardpgaspar
Product-flask-appbuilderFlask-AppBuilder
CWE ID-CWE-601
URL Redirection to Untrusted Site ('Open Redirect')
CVE-2021-32786
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-4.7||MEDIUM
EPSS-0.10% / 27.17%
||
7 Day CHG-0.02%
Published-22 Jul, 2021 | 00:00
Updated-03 Aug, 2024 | 23:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Open Redirect in oidc_validate_redirect_url()

mod_auth_openidc is an authentication/authorization module for the Apache 2.x HTTP server that functions as an OpenID Connect Relying Party, authenticating users against an OpenID Connect Provider. In versions prior to 2.4.9, `oidc_validate_redirect_url()` does not parse URLs the same way as most browsers do. As a result, this function can be bypassed and leads to an Open Redirect vulnerability in the logout functionality. This bug has been fixed in version 2.4.9 by replacing any backslash of the URL to redirect with slashes to address a particular breaking change between the different specifications (RFC2396 / RFC3986 and WHATWG). As a workaround, this vulnerability can be mitigated by configuring `mod_auth_openidc` to only allow redirection whose destination matches a given regular expression.

Action-Not Available
Vendor-openidczmartzoneThe Apache Software FoundationFedora Project
Product-mod_auth_openidchttp_serverfedoramod_auth_openidc
CWE ID-CWE-601
URL Redirection to Untrusted Site ('Open Redirect')
CVE-2021-31879
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.1||MEDIUM
EPSS-0.15% / 36.20%
||
7 Day CHG~0.00%
Published-29 Apr, 2021 | 03:03
Updated-03 Aug, 2024 | 23:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

GNU Wget through 1.21.1 does not omit the Authorization header upon a redirect to a different origin, a related issue to CVE-2018-1000007.

Action-Not Available
Vendor-n/aNetApp, Inc.GNUBroadcom Inc.
Product-500f500f_firmwarea250_firmwarecloud_backupontap_select_deploy_administration_utilitya250wgetbrocade_fabric_operating_system_firmwaren/a
CWE ID-CWE-601
URL Redirection to Untrusted Site ('Open Redirect')
CVE-2022-35953
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-7.1||HIGH
EPSS-0.25% / 48.39%
||
7 Day CHG~0.00%
Published-12 Aug, 2022 | 20:15
Updated-22 Apr, 2025 | 17:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
URL Redirection to Untrusted Site ('Open Redirect') in bookwyrm

BookWyrm is a social network for tracking your reading, talking about books, writing reviews, and discovering what to read next. Some links in BookWyrm may be vulnerable to tabnabbing, a form of phishing that gives attackers an opportunity to redirect a user to a malicious site. The issue was patched in version 0.4.5.

Action-Not Available
Vendor-joinbookwyrmbookwyrm-social
Product-bookwyrmbookwyrm
CWE ID-CWE-601
URL Redirection to Untrusted Site ('Open Redirect')
CVE-2022-3486
Matching Score-4
Assigner-GitLab Inc.
ShareView Details
Matching Score-4
Assigner-GitLab Inc.
CVSS Score-4.7||MEDIUM
EPSS-0.38% / 58.99%
||
7 Day CHG~0.00%
Published-09 Nov, 2022 | 00:00
Updated-01 May, 2025 | 20:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An open redirect vulnerability in GitLab EE/CE affecting all versions from 9.3 prior to 15.3.5, 15.4 prior to 15.4.4, and 15.5 prior to 15.5.2, allows an attacker to redirect users to an arbitrary location if they trust the URL.

Action-Not Available
Vendor-GitLab Inc.
Product-gitlabGitLab
CWE ID-CWE-601
URL Redirection to Untrusted Site ('Open Redirect')
CVE-2025-11222
Matching Score-4
Assigner-LY Corporation
ShareView Details
Matching Score-4
Assigner-LY Corporation
CVSS Score-6.1||MEDIUM
EPSS-0.04% / 11.27%
||
7 Day CHG~0.00%
Published-04 Dec, 2025 | 12:18
Updated-19 Dec, 2025 | 18:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Central Dogma versions before 0.78.0 contain an Open Redirect vulnerability that allows attackers to redirect users to untrusted sites via specially crafted URLs, potentially facilitating phishing attacks and credential theft.

Action-Not Available
Vendor-linecorpLINE Corporation
Product-central_dogmaCentral Dogma
CWE ID-CWE-601
URL Redirection to Untrusted Site ('Open Redirect')
CVE-2021-32721
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-4.7||MEDIUM
EPSS-0.20% / 41.92%
||
7 Day CHG~0.00%
Published-29 Jun, 2021 | 18:40
Updated-03 Aug, 2024 | 23:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
URL Redirection to Untrusted Site ('Open Redirect') in github.com/AndrewBurian/powermux

PowerMux is a drop-in replacement for Go's http.ServeMux. In PowerMux versions prior to 1.1.1, attackers may be able to craft phishing links and other open redirects by exploiting the trailing slash redirection feature. This may lead to users being redirected to untrusted sites after following an attacker crafted link. The issue is resolved in v1.1.1. There are no existing workarounds.

Action-Not Available
Vendor-powermux_projectAndrewBurian
Product-powermuxpowermux
CWE ID-CWE-601
URL Redirection to Untrusted Site ('Open Redirect')
CVE-2021-32806
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-6.5||MEDIUM
EPSS-0.30% / 52.89%
||
7 Day CHG~0.00%
Published-02 Aug, 2021 | 18:25
Updated-03 Aug, 2024 | 23:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
URL Redirection to Untrusted Site ('Open Redirect') in Products.isurlinportal

Products.isurlinportal is a replacement for isURLInPortal method in Plone. Versions of Products.isurlinportal prior to 1.2.0 have an Open Redirect vulnerability. Various parts of Plone use the 'is url in portal' check for security, mostly to see if it is safe to redirect to a url. A url like `https://example.org` is not in the portal. The url `https:example.org` without slashes is considered to be in the portal. When redirecting, some browsers go to `https://example.org`, others give an error. Attackers may use this to redirect victims to their site, especially as part of a phishing attack. The problem has been patched in Products.isurlinportal 1.2.0.

Action-Not Available
Vendor-Plone Foundation
Product-isurlinportalProducts.isurlinportal
CWE ID-CWE-601
URL Redirection to Untrusted Site ('Open Redirect')
CVE-2026-24323
Matching Score-4
Assigner-SAP SE
ShareView Details
Matching Score-4
Assigner-SAP SE
CVSS Score-6.1||MEDIUM
EPSS-0.05% / 16.10%
||
7 Day CHG~0.00%
Published-10 Feb, 2026 | 03:04
Updated-10 Feb, 2026 | 16:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Multiple vulnerabilities in BSP Applications of SAP Document Management System

The BSP applications allow an unauthenticated user to inject malicious script content via user-controlled URL parameters that are not sufficiently sanitized. When a victim accesses a crafted URL, the injected script is executed in the victim�s browser, leading to a low impact on confidentiality and integrity, and no impact on the availability of the application.

Action-Not Available
Vendor-SAP SE
Product-SAP Document Management System
CWE ID-CWE-601
URL Redirection to Untrusted Site ('Open Redirect')
CVE-2008-2951
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.1||MEDIUM
EPSS-0.60% / 68.92%
||
7 Day CHG~0.00%
Published-27 Jul, 2008 | 22:00
Updated-07 Aug, 2024 | 09:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Open redirect vulnerability in the search script in Trac before 0.10.5 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks via a URL in the q parameter, possibly related to the quickjump function.

Action-Not Available
Vendor-edgewalln/aFedora Project
Product-tracfedoran/a
CWE ID-CWE-601
URL Redirection to Untrusted Site ('Open Redirect')
CVE-2026-23729
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-4.8||MEDIUM
EPSS-0.03% / 8.36%
||
7 Day CHG~0.00%
Published-16 Jan, 2026 | 19:47
Updated-30 Jan, 2026 | 18:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
WeGIA has an Open Redirect Vulnerability in control.php Endpoint via nextPage Parameter (metodo=listarDescricao, nomeClasse=ProdutoControle)

WeGIA is a web manager for charitable institutions. Prior to 3.6.2, an Open Redirect vulnerability was identified in the /WeGIA/controle/control.php endpoint of the WeGIA application, specifically through the nextPage parameter when combined with metodo=listarDescricao and nomeClasse=ProdutoControle. The application fails to validate or restrict the nextPage parameter, allowing attackers to redirect users to arbitrary external websites. This can be abused for phishing attacks, credential theft, malware distribution, and social engineering using the trusted WeGIA domain. This vulnerability is fixed in 3.6.2.

Action-Not Available
Vendor-wegiaLabRedesCefetRJ
Product-wegiaWeGIA
CWE ID-CWE-601
URL Redirection to Untrusted Site ('Open Redirect')
CVE-2026-23728
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-4.8||MEDIUM
EPSS-0.03% / 8.36%
||
7 Day CHG~0.00%
Published-16 Jan, 2026 | 19:46
Updated-30 Jan, 2026 | 18:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
WeGIA has an Open Redirect Vulnerability in control.php Endpoint via nextPage Parameter (metodo=listarTodos, nomeClasse=DestinoControle)

WeGIA is a web manager for charitable institutions. Prior to 3.6.2, an Open Redirect vulnerability was identified in the /WeGIA/controle/control.php endpoint of the WeGIA application, specifically through the nextPage parameter when combined with metodo=listarTodos and nomeClasse=DestinoControle. The application fails to validate or restrict the nextPage parameter, allowing attackers to redirect users to arbitrary external websites. This can be abused for phishing attacks, credential theft, malware distribution, and social engineering using the trusted WeGIA domain. This vulnerability is fixed in 3.6.2.

Action-Not Available
Vendor-wegiaLabRedesCefetRJ
Product-wegiaWeGIA
CWE ID-CWE-601
URL Redirection to Untrusted Site ('Open Redirect')
CVE-2026-25956
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-6.1||MEDIUM
EPSS-0.03% / 7.49%
||
7 Day CHG~0.00%
Published-10 Feb, 2026 | 17:39
Updated-10 Feb, 2026 | 21:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Frappe Affected by XSS and Open Redirect in Sign Up

Frappe is a full-stack web application framework. Prior to 14.99.14 and 15.94.0, an attacker could craft a malicious signup URL for a frappe site which could lead to an open redirect (or reflected XSS, depending on the crafted payload) when a user signs up. This vulnerability is fixed in 14.99.14 and 15.94.0.

Action-Not Available
Vendor-frappe
Product-frappe
CWE ID-CWE-601
URL Redirection to Untrusted Site ('Open Redirect')
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2021-3189
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.1||MEDIUM
EPSS-0.11% / 30.42%
||
7 Day CHG~0.00%
Published-19 Feb, 2021 | 22:24
Updated-03 Aug, 2024 | 16:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The slashify package 1.0.0 for Node.js allows open-redirect attacks, as demonstrated by a localhost:3000///example.com/ substring.

Action-Not Available
Vendor-n/aGoogle LLC
Product-slashifyn/a
CWE ID-CWE-601
URL Redirection to Untrusted Site ('Open Redirect')
CVE-2026-23726
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-4.8||MEDIUM
EPSS-0.03% / 8.36%
||
7 Day CHG~0.00%
Published-16 Jan, 2026 | 19:40
Updated-30 Jan, 2026 | 18:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
WeGIA has an Open Redirect Vulnerability in control.php Endpoint via nextPage Parameter (metodo=listarTodos, nomeClasse=TipoEntradaControle)

WeGIA is a web manager for charitable institutions. Prior to 3.6.2, An Open Redirect vulnerability was identified in the /WeGIA/controle/control.php endpoint of the WeGIA application, specifically through the nextPage parameter when combined with metodo=listarTodos and nomeClasse=TipoEntradaControle. The application fails to validate or restrict the nextPage parameter, allowing attackers to redirect users to arbitrary external websites. This can be abused for phishing attacks, credential theft, malware distribution, and social engineering using the trusted WeGIA domain. This vulnerability is fixed in 3.6.2.

Action-Not Available
Vendor-wegiaLabRedesCefetRJ
Product-wegiaWeGIA
CWE ID-CWE-601
URL Redirection to Untrusted Site ('Open Redirect')
CVE-2021-32618
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-3.1||LOW
EPSS-17.16% / 94.84%
||
7 Day CHG~0.00%
Published-17 May, 2021 | 18:05
Updated-03 Aug, 2024 | 23:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Open Redirect Vulnerability

The Python "Flask-Security-Too" package is used for adding security features to your Flask application. It is an is an independently maintained version of Flask-Security based on the 3.0.0 version of Flask-Security. All versions of Flask-Security-Too allow redirects after many successful views (e.g. /login) by honoring the ?next query param. There is code in FS to validate that the url specified in the next parameter is either relative OR has the same netloc (network location) as the requesting URL. This check utilizes Pythons urlsplit library. However many browsers are very lenient on the kind of URL they accept and 'fill in the blanks' when presented with a possibly incomplete URL. As a concrete example - setting http://login?next=\\\github.com will pass FS's relative URL check however many browsers will gladly convert this to http://github.com. Thus an attacker could send such a link to an unwitting user, using a legitimate site and have it redirect to whatever site they want. This is considered a low severity due to the fact that if Werkzeug is used (which is very common with Flask applications) as the WSGI layer, it by default ALWAYS ensures that the Location header is absolute - thus making this attack vector mute. It is possible for application writers to modify this default behavior by setting the 'autocorrect_location_header=False`.

Action-Not Available
Vendor-flask-security_projectFlask-Middleware
Product-flask-securityflask-security
CWE ID-CWE-601
URL Redirection to Untrusted Site ('Open Redirect')
CVE-2026-23730
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-4.8||MEDIUM
EPSS-0.03% / 8.36%
||
7 Day CHG~0.00%
Published-16 Jan, 2026 | 19:48
Updated-30 Jan, 2026 | 18:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
WeGIA has an Open Redirect Vulnerability in control.php Endpoint via nextPage Parameter (metodo=listarTodos, nomeClasse=ProdutoControle)

WeGIA is a web manager for charitable institutions. Prior to 3.6.2, an Open Redirect vulnerability was identified in the /WeGIA/controle/control.php endpoint of the WeGIA application, specifically through the nextPage parameter when combined with metodo=listarTodos and nomeClasse=ProdutoControle. The application fails to validate or restrict the nextPage parameter, allowing attackers to redirect users to arbitrary external websites. This can be abused for phishing attacks, credential theft, malware distribution, and social engineering using the trusted WeGIA domain. This vulnerability is fixed in 3.6.2.

Action-Not Available
Vendor-wegiaLabRedesCefetRJ
Product-wegiaWeGIA
CWE ID-CWE-601
URL Redirection to Untrusted Site ('Open Redirect')
CVE-2026-23727
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-4.8||MEDIUM
EPSS-0.03% / 8.36%
||
7 Day CHG~0.00%
Published-16 Jan, 2026 | 19:41
Updated-30 Jan, 2026 | 18:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
WeGIA has an Open Redirect Vulnerability in control.php Endpoint via nextPage Parameter (metodo=listarTodos, nomeClasse=TipoSaidaControle)

WeGIA is a web manager for charitable institutions. Prior to 3.6.2, an Open Redirect vulnerability was identified in the /WeGIA/controle/control.php endpoint of the WeGIA application, specifically through the nextPage parameter when combined with metodo=listarTodos and nomeClasse=TipoSaidaControle. The application fails to validate or restrict the nextPage parameter, allowing attackers to redirect users to arbitrary external websites. This can be abused for phishing attacks, credential theft, malware distribution, and social engineering using the trusted WeGIA domain. This vulnerability is fixed in 3.6.2.

Action-Not Available
Vendor-wegiaLabRedesCefetRJ
Product-wegiaWeGIA
CWE ID-CWE-601
URL Redirection to Untrusted Site ('Open Redirect')
CVE-2026-24768
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-5.7||MEDIUM
EPSS-0.01% / 2.30%
||
7 Day CHG~0.00%
Published-28 Jan, 2026 | 20:32
Updated-04 Feb, 2026 | 20:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
NocoDB has Unvalidated Redirect in Login Flow via continueAfterSignIn Parameter

NocoDB is software for building databases as spreadsheets. Prior to version 0.301.0, an unvalidated redirect (open redirect) vulnerability exists in NocoDB’s login flow due to missing validation of the `continueAfterSignIn` parameter. During authentication, NocoDB processes a user-controlled redirect value and conditionally performs client-side navigation without enforcing any restrictions on the destination’s origin, domain or protocol. This allows attackers to redirect authenticated users to arbitrary external websites after login. This vulnerability enables phishing attacks by leveraging user trust in the legitimate NocoDB login flow. While it does not directly expose credentials or bypass authentication, it increases the likelihood of credential theft through social engineering. The issue does not allow arbitrary code execution or privilege escalation, but it undermines authentication integrity. Version 0.301.0 fixes the issue.

Action-Not Available
Vendor-nocodbnocodb
Product-nocodbnocodb
CWE ID-CWE-601
URL Redirection to Untrusted Site ('Open Redirect')
CVE-2026-24328
Matching Score-4
Assigner-SAP SE
ShareView Details
Matching Score-4
Assigner-SAP SE
CVSS Score-6.1||MEDIUM
EPSS-0.05% / 16.10%
||
7 Day CHG~0.00%
Published-10 Feb, 2026 | 03:04
Updated-10 Feb, 2026 | 15:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Open Redirection vulnerability in Business Server Pages Application (TAF_APPLAUNCHER)

SAP TAF_APPLAUNCHER within Business Server Pages allows unauthenticated attacker to craft malicious links that, when clicked by a victim, redirect them to attacker?controlled sites, potentially exposing or altering sensitive information in the victim�s browser. This results in a low impact on confidentiality and integrity, with no impact on the availability of the application.

Action-Not Available
Vendor-SAP SE
Product-Business Server Pages Application (TAF_APPLAUNCHER)
CWE ID-CWE-601
URL Redirection to Untrusted Site ('Open Redirect')
  • Previous
  • 1
  • 2
  • 3
  • ...
  • 14
  • 15
  • Next
Details not found