An Improper Check for Unusual or Exceptional Conditions vulnerability in the chassis management daemon (chassisd) of Juniper Networks Junos OS allows an unauthenticated, network-based attacker to cause a Denial-of-Service (DoS). If an attempt is made to access specific sensors on platforms not supporting these sensors, either via GRPC or netconf, chassisd will crash and restart leading to a restart of all FPCs and thereby a complete outage. This issue affects Junos OS: * 21.4 versions from 21.4R3 before 21.4R3-S5, * 22.1 versions from 22.1R3 before 22.1R3-S4, * 22.2 versions from 22.2R2 before 22.2R3, * 22.3 versions from 22.3R1 before 22.3R2-S2, 22.3R3, * 22.4 versions from 22.4R1 before 22.4R2. This issue does not affect Junos OS versions earlier than 21.4.
An Improper Check for Unusual or Exceptional Conditions vulnerability in packet processing of Juniper Networks Junos OS Evolved may allow a network-based unauthenticated attacker to crash the device (vmcore) by sending a specific TCP packet over an established TCP session with MD5 authentication enabled, destined to an accessible port on the device, resulting in a Denial of Service (DoS). The receipt of this packet must occur within a specific timing window outside the attacker's control (i.e., race condition). Continued receipt and processing of this packet will create a sustained Denial of Service (DoS) condition. This issue only affects dual RE systems with Nonstop Active Routing (NSR) enabled. Exploitation can only occur over TCP sessions with MD5 authentication enabled (e.g., BGP with MD5 authentication). This issue affects Junos OS Evolved: * All versions before 21.2R3-S8-EVO, * from 21.4-EVO before 21.4R3-S6-EVO, * from 22.1-EVO before 22.1R3-S4-EVO, * from 22.2-EVO before 22.2R3-S4-EVO, * from 22.3-EVO before 22.3R3-S3-EVO, * from 22.4-EVO before 22.4R2-S2-EVO, 22.4R3-EVO.
An Improper Check for Unusual or Exceptional Conditions vulnerability in the flow daemon (flowd) of Juniper Networks Junos OS on SRX4600 and SRX5000 Series allows an attacker to send TCP packets with SYN/FIN or SYN/RST flags, bypassing the expected blocking of these packets. A TCP packet with SYN/FIN or SYN/RST should be dropped in flowd. However, when no-syn-check and Express Path are enabled, these TCP packets are unexpectedly transferred to the downstream network. This issue affects Junos OS on SRX4600 and SRX5000 Series: * All versions before 21.2R3-S8, * from 21.4 before 21.4R3-S7, * from 22.1 before 22.1R3-S6, * from 22.2 before 22.2R3-S4, * from 22.3 before 22.3R3-S3, * from 22.4 before 22.4R3-S2, * from 23.2 before 23.2R2, * from 23.4 before 23.4R1-S1, 23.4R2.
An Improper Check for Unusual or Exceptional Conditions vulnerability combined with Improper Handling of Exceptional Conditions in Juniper Networks Junos OS on QFX Series and PTX Series allows an unauthenticated network based attacker to cause increased FPC CPU utilization by sending specific IP packets which are being VXLAN encapsulated leading to a partial Denial of Service (DoS). Continued receipted of these specific traffic will create a sustained Denial of Service (DoS) condition. This issue affects: Juniper Networks Junos OS on QFX Series: All versions prior to 17.3R3-S11; 17.4 versions prior to 17.4R2-S13, 17.4R3-S4; 18.1 versions prior to 18.1R3-S12; 18.2 versions prior to 18.2R2-S8, 18.2R3-S7; 18.3 versions prior to 18.3R3-S4; 18.4 versions prior to 18.4R1-S8, 18.4R2-S7, 18.4R3-S7; 19.1 versions prior to 19.1R1-S6, 19.1R2-S2, 19.1R3-S4; 19.2 versions prior to 19.2R1-S6, 19.2R3-S2; 19.3 versions prior to 19.3R3-S1; 19.4 versions prior to 19.4R2-S3, 19.4R3-S1; 20.1 versions prior to 20.1R2, 20.1R3; 20.2 versions prior to 20.2R2, 20.2R3; 20.3 versions prior to 20.3R1-S1, 20.3R2. Juniper Networks Junos OS on PTX Series: All versions prior to 18.4R3-S9; 19.1 versions prior to 19.1R3-S6; 19.2 versions prior to 19.2R1-S7, 19.2R3-S3; 19.3 versions prior to 19.3R2-S6, 19.3R3-S3; 19.4 versions prior to 19.4R1-S4, 19.4R3-S5; 20.1 versions prior to 20.1R2-S2, 20.1R3; 20.2 versions prior to 20.2R3-S1; 20.3 versions prior to 20.3R2-S1, 20.3R3; 20.4 versions prior to 20.4R2-S1, 20.4R3; 21.1 versions prior to 21.1R1-S1, 21.1R2.
An Improper Check for Unusual or Exceptional Conditions in packet processing on the MS-MPC/MS-MIC utilized by Juniper Networks Junos OS allows a malicious attacker to send a specific packet, triggering the MS-MPC/MS-MIC to reset, causing a Denial of Service (DoS). Continued receipt and processing of this packet will create a sustained Denial of Service (DoS) condition. This issue only affects specific versions of Juniper Networks Junos OS on MX Series: 17.3R3-S11; 17.4R2-S13; 17.4R3 prior to 17.4R3-S5; 18.1R3-S12; 18.2R2-S8, 18.2R3-S7, 18.2R3-S8; 18.3R3-S4; 18.4R3-S7; 19.1R3-S4, 19.1R3-S5; 19.2R1-S6; 19.3R3-S2; 19.4R2-S4, 19.4R2-S5; 19.4R3-S2; 20.1R2-S1; 20.2R2-S2, 20.2R2-S3, 20.2R3; 20.3R2, 20.3R2-S1; 20.4R1, 20.4R1-S1, 20.4R2; 21.1R1; This issue does not affect any version of Juniper Networks Junos OS prior to 15.1X49-D240;
An Improper Check for Unusual or Exceptional Conditions vulnerability in the routing protocol daemon (RPD) of Juniper Networks Junos OS and Junos OS Evolved allows an unauthenticated, network based attacker to cause a Denial of Service (DoS). In a scenario where BGP Monitoring Protocol (BMP) is configured with rib-in pre-policy monitoring, receiving a BGP update with a specifically malformed AS PATH attribute over an established BGP session, can cause an RPD crash and restart. This issue affects: Junos OS: * All versions before 21.2R3-S8, * 21.4 versions before 21.4R3-S8, * 22.2 versions before 22.2R3-S4, * 22.3 versions before 22.3R3-S3, * 22.4 versions before 22.4R3-S2, * 23.2 versions before 23.2R2-S1, * 23.4 versions before 23.4R1-S2, 23.4R2; Junos OS Evolved: * All versions before 21.2R3-S8-EVO, * 21.4 versions before 21.4R3-S8-EVO, * 22.2 versions before 22.2R3-S4-EVO, * 22.3 versions before 22.3R3-S3-EVO, * 22.4 versions before 22.4R3-S2-EVO, * 23.2 versions before 23.2R2-S1-EVO, * 23.4 versions before 23.4R1-S2-EVO, 23.4R2-EVO.
An Improper Check for Unusual or Exceptional Conditions vulnerability in the flow processing daemon (flowd) of Juniper Networks Junos OS on SRX4600 and SRX5000 Series allows an unauthenticated and logically adjacent attacker to cause a Denial-of-Service (DoS). If in a multicast scenario a sequence of specific PIM packets is received, this will cause a flowd crash and restart, which leads to momentary service interruption. This issue affects Junos OS on SRX 4600 and SRX 5000 Series: * All versions before 21.4R3-S9, * 22.2 versions before 22.2R3-S5, * 22.3 versions before 22.3R3-S4, * 22.4 versions before 22.4R3-S4, * 23.2 versions before 23.2R2-S2, * 23.4 versions before 23.4R2, * 24.2 versions before 24.2R1-S1, 24.2R2.
An Improper Check for Unusual or Exceptional Conditions vulnerability in the Layer 2 Address Learning Daemon (l2ald) of Juniper Networks Junos OS and Junos OS Evolved allows an unauthenticated, adjacent attacker to cause a Denial of Service (DoS). When telemetry requests are sent to the device, and the Dynamic Rendering Daemon (drend) is suspended, the l2ald crashes and restarts due to factors outside the attackers control. Repeated occurrences of these events causes a sustained DoS condition. This issue affects: Junos OS: * All versions earlier than 20.4R3-S10; * 21.2 versions earlier than 21.2R3-S7; * 21.4 versions earlier than 21.4R3-S5; * 22.1 versions earlier than 22.1R3-S4; * 22.2 versions earlier than 22.2R3-S3; * 22.3 versions earlier than 22.3R3-S1; * 22.4 versions earlier than 22.4R3; * 23.2 versions earlier than 23.2R1-S2, 23.2R2. Junos OS Evolved: * All versions earlier than 21.4R3-S5-EVO; * 22.1-EVO versions earlier than 22.1R3-S4-EVO; * 22.2-EVO versions earlier than 22.2R3-S3-EVO; * 22.3-EVO versions earlier than 22.3R3-S1-EVO; * 22.4-EVO versions earlier than 22.4R3-EVO; * 23.2-EVO versions earlier than 23.2R2-EVO.
An Improper Check for Unusual or Exceptional Conditions vulnerability in the Packet Forwarding Engine (PFE) of Juniper Networks Junos OS on EX4300 Series allows a locally authenticated attacker with low privileges to cause a Denial-of-Service (Dos). If a specific CLI command is issued, a PFE crash will occur. This will cause traffic forwarding to be interrupted until the system self-recovers. This issue affects Junos OS: All versions before 20.4R3-S10, 21.2 versions before 21.2R3-S7, 21.4 versions before 21.4R3-S6.
An Improper Check for Unusual or Exceptional Conditions vulnerability in the the Public Key Infrastructure daemon (pkid) of Juniper Networks Junos OS allows an unauthenticated networked attacker to cause Denial of Service (DoS). The pkid is responsible for the certificate verification. Upon a failed verification, the pkid uses all CPU resources and becomes unresponsive to future verification attempts. This means that all subsequent VPN negotiations depending on certificate verification will fail. This CPU utilization of pkid can be checked using this command: root@srx> show system processes extensive | match pkid xxxxx root 103 0 846M 136M CPU1 1 569:00 100.00% pkid This issue affects: Juniper Networks Junos OS * All versions prior to 20.4R3-S10; * 21.2 versions prior to 21.2R3-S7; * 21.4 versions prior to 21.4R3-S5; * 22.1 versions prior to 22.1R3-S4; * 22.2 versions prior to 22.2R3-S3; * 22.3 versions prior to 22.3R3-S1; * 22.4 versions prior to 22.4R3; * 23.2 versions prior to 23.2R1-S2, 23.2R2.
An Improper Check for Unusual or Exceptional Conditions in the Packet Forwarding Engine (pfe) of Juniper Networks Junos OS Evolved on PTX10003 Series allows an unauthenticated adjacent attacker to cause an impact to the integrity of the system. When specific transit MPLS packets are received by the PFE, these packets are internally forwarded to the RE. This issue is a prerequisite for CVE-2023-44195. This issue affects Juniper Networks Junos OS Evolved: * All versions prior to 20.4R3-S8-EVO; * 21.1-EVO version 21.1R1-EVO and later; * 21.2-EVO versions prior to 21.2R3-S6-EVO; * 21.3-EVO version 21.3R1-EVO and later; * 21.4-EVO versions prior to 21.4R3-S3-EVO; * 22.1-EVO versions prior to 22.1R3-S4-EVO; * 22.2-EVO versions prior to 22.2R3-S3-EVO; * 22.3-EVO versions prior to 22.3R2-S2-EVO, 22.3R3-EVO; * 22.4-EVO versions prior to 22.4R2-EVO.
An Improper Check for Unusual or Exceptional Conditions vulnerability in the SIP ALG of Juniper Networks Junos OS on SRX Series and MX Series allows an unauthenticated network-based attacker to cause an integrity impact in connected networks. If the SIP ALG is configured and a device receives a specifically malformed SIP packet, the device prevents this packet from being forwarded, but any subsequently received retransmissions of the same packet are forwarded as if they were valid. This issue affects Juniper Networks Junos OS on SRX Series and MX Series: * 20.4 versions prior to 20.4R3-S5; * 21.1 versions prior to 21.1R3-S4; * 21.2 versions prior to 21.2R3-S4; * 21.3 versions prior to 21.3R3-S3; * 21.4 versions prior to 21.4R3-S2; * 22.1 versions prior to 22.1R2-S2, 22.1R3; * 22.2 versions prior to 22.2R2-S1, 22.2R3; * 22.3 versions prior to 22.3R1-S2, 22.3R2. This issue doesn't not affected releases prior to 20.4R1.
In a Segment Routing ISIS (SR-ISIS)/MPLS environment, on Juniper Networks Junos OS and Junos OS Evolved devices, configured with ISIS Flexible Algorithm for Segment Routing and sensor-based statistics, a flap of a ISIS link in the network, can lead to a routing process daemon (RPD) crash and restart, causing a Denial of Service (DoS). Continued link flaps will create a sustained Denial of Service (DoS) condition. This issue affects: Juniper Networks Junos OS: 19.4 versions prior to 19.4R1-S4, 19.4R3-S2; 20.1 versions prior to 20.1R2-S1, 20.1R3; 20.2 versions prior to 20.2R2-S2, 20.2R3; 20.3 versions prior to 20.3R2; Juniper Networks Junos OS Evolved: 20.3-EVO versions prior to 20.3R2-EVO; 20.4-EVO versions prior to 20.4R2-EVO. This issue does not affect: Juniper Networks Junos OS releases prior to 19.4R1. Juniper Networks Junos OS Evolved releases prior to 19.4R1-EVO.
An improper check for unusual or exceptional conditions in Juniper Networks Junos OS and Junos OS Evolved Routing Protocol Daemon (RPD) service allows an attacker to send a valid BGP FlowSpec message thereby causing an unexpected change in the route advertisements within the BGP FlowSpec domain leading to disruptions in network traffic causing a Denial of Service (DoS) condition. Continued receipt of these update messages will cause a sustained Denial of Service condition. This issue affects Juniper Networks: Junos OS: All versions prior to 17.3R3-S10 with the exceptions of 15.1X49-D240 on SRX Series and 15.1R7-S8 on EX Series; 17.3 versions prior to 17.3R3-S10; 17.4 versions prior to 17.4R2-S12, 17.4R3-S4; 18.1 versions prior to 18.1R3-S12; 18.2 versions prior to 18.2R2-S8, 18.2R3-S6; 18.3 versions prior to 18.3R3-S4; 18.4 versions prior to 18.4R1-S8, 18.4R2-S6, 18.4R3-S6; 19.1 versions prior to 19.1R1-S6, 19.1R2-S2, 19.1R3-S3; 19.2 versions prior to 19.2R3-S1; 19.3 versions prior to 19.3R2-S5, 19.3R3-S1; 19.4 versions prior to 19.4R1-S3, 19.4R2-S3, 19.4R3; 20.1 versions prior to 20.1R2; 20.2 versions prior to 20.2R1-S3 20.2R2; 20.3 versions prior to 20.3R1-S1, 20.3R2. Junos OS Evolved: All versions prior to 20.3R1-S1-EVO, 20.3R2-EVO.
An Improper Check for Unusual or Exceptional Conditions vulnerability in the Packet Forwarding Engine (PFE) of Juniper Networks Junos OS on SRX Series and NFX Series allows an unauthenticated, network-based attacker to cause a Denial-of-Service (DoS). If an affected device receives specific valid traffic destined to the device, it will cause the PFE to crash and restart. Continued receipt and processing of this traffic will create a sustained DoS condition. This issue affects Junos OS on SRX Series: * 21.4 versions before 21.4R3-S7.9, * 22.1 versions before 22.1R3-S5.3, * 22.2 versions before 22.2R3-S4.11, * 22.3 versions before 22.3R3, * 22.4 versions before 22.4R3. This issue affects Junos OS on NFX Series: * 21.4 versions before 21.4R3-S8, * 22.1 versions after 22.1R1, * 22.2 versions before 22.2R3-S5, * 22.3 versions before 22.3R3, * 22.4 versions before 22.4R3. Junos OS versions prior to 21.4R1 are not affected by this issue.
An Improper Check for Unusual or Exceptional Conditions vulnerability in the Packet Forwarding Engine (PFE) of Juniper Networks Junos OS on QFX10000 Series allows a network based attacker to cause a Denial of Service (DoS). If a specific valid IP packet is received and that packet needs to be routed over a VXLAN tunnel, this will result in a PFE wedge condition due to which traffic gets impacted. As this is not a crash and restart scenario, this condition will persist until the system is rebooted to recover. This issue affects Juniper Networks Junos OS on QFX10000: 20.3 version 20.3R1 and later versions; 20.4 versions prior to 20.4R3-S5; 21.1 versions prior to 21.1R3-S5; 21.2 versions prior to 21.2R3-S5; 21.3 versions prior to 21.3R3-S4; 21.4 versions prior to 21.4R3-S1; 22.1 versions prior to 22.1R3; 22.2 versions prior to 22.2R2; 22.3 versions prior to 22.3R1-S2, 22.3R2.
An Improper Check for Unusual or Exceptional Conditions vulnerability in the Packet Forwarding Engine (PFE) of Juniper Networks Junos OS Evolved on ACX7000 Series allows an unauthenticated, adjacent attacker to cause a Denial-of-Service (DoS). On all ACX 7000 Series platforms running Junos OS Evolved, and configured with IRBs, if a Customer Edge device (CE) device is dual homed to two Provider Edge devices (PE) a traffic loop will occur when the CE sends multicast packets. This issue can be triggered by IPv4 and IPv6 traffic. This issue affects Junos OS Evolved: All versions from 22.2R1-EVO and later versions before 22.4R2-EVO, This issue does not affect Junos OS Evolved versions before 22.1R1-EVO.
An Improper Check for Unusual or Exceptional Conditions vulnerability in the packet forwarding engine (pfe) of Juniper Networks Junos OS on MX Series allows an unauthenticated, network-based attacker to cause a Denial of Service (DoS). If specific traffic is received on MX Series and its rate exceeds the respective DDoS protection limit the ingress PFE will crash and restart. Continued receipt of this traffic will create a sustained DoS condition. This issue affects Juniper Networks Junos OS on MX Series: All versions prior to 19.1R3-S10; 19.2 versions prior to 19.2R3-S7; 19.3 versions prior to 19.3R3-S8; 19.4 versions prior to 19.4R3-S11; 20.2 versions prior to 20.2R3-S5; 20.4 versions prior to 20.4R3-S6; 21.1 versions prior to 21.1R3-S5; 21.2 versions prior to 21.2R3-S4; 21.3 versions prior to 21.3R3; 21.4 versions prior to 21.4R3; 22.1 versions prior to 22.1R2.
An Improper Check or Handling of Exceptional Conditions within the storm control feature of Juniper Networks Junos OS allows an attacker sending a high rate of traffic to cause a Denial of Service. Continued receipt and processing of these packets will create a sustained Denial of Service (DoS) condition. Storm control monitors the level of applicable incoming traffic and compares it with the level specified. If the combined level of the applicable traffic exceeds the specified level, the switch drops packets for the controlled traffic types. This issue affects Juniper Networks Junos OS on QFX10002: All versions prior to 19.3R3-S7; 19.4 versions prior to 19.4R3-S11; 20.2 versions prior to 20.2R3-S6; 20.4 versions prior to 20.4R3-S5; 21.1 versions prior to 21.1R3-S4; 21.2 versions prior to 21.2R3-S3; 21.3 versions prior to 21.3R3; 21.4 versions prior to 21.4R2.
The SRX flowd process, responsible for packet forwarding, may crash and restart when processing specific multicast packets. By continuously sending the specific multicast packets, an attacker can repeatedly crash the flowd process causing a sustained Denial of Service. This issue affects Juniper Networks Junos OS on SRX Series: 12.3X48 versions prior to 12.3X48-D90; 15.1X49 versions prior to 15.1X49-D180; 17.3 versions; 17.4 versions prior to 17.4R2-S5, 17.4R3; 18.1 versions prior to 18.1R3-S6; 18.2 versions prior to 18.2R2-S4, 18.2R3; 18.3 versions prior to 18.3R2-S1, 18.3R3; 18.4 versions prior to 18.4R2; 19.1 versions prior to 19.1R1-S1, 19.1R2.
On EX4300-MP Series devices with any lo0 filters applied, transit network traffic may reach the control plane via loopback interface (lo0). The device may fail to forward such traffic. This issue affects Juniper Networks Junos OS 18.2 versions prior to 18.2R1-S2, 18.2R2 on EX4300-MP Series. This issue does not affect any other EX series devices.
An Improper Check for Unusual or Exceptional Conditions vulnerability in the kernel of Juniper Networks Junos OS allows an adjacent unauthenticated attacker to bypass an integrity check. In a 6PE scenario and if an additional integrity check is configured, it will fail to drop specific malformed IPv6 packets, and then these packets will be forwarded to other connected networks. This issue affects Juniper Networks Junos OS: All versions prior to 19.3R3-S7; 19.4 versions prior to 19.4R3-S9; 20.2 versions prior to 20.2R3-S7; 20.3 versions prior to 20.3R3-S5; 20.4 versions prior to 20.4R3-S4; 21.1 versions prior to 21.1R3-S3; 21.2 versions prior to 21.2R3-S2; 21.3 versions prior to 21.3R3-S1; 21.4 versions prior to 21.4R2-S1, 21.4R3; 22.1 versions prior to 22.1R2; 22.2 versions prior to 22.2R2.
An Improper Check for Unusual or Exceptional Conditions vulnerability in the bbe-smgd of Juniper Networks Junos OS allows an unauthenticated, adjacent attacker to cause a Denial of Service (DoS). In a Broadband Edge / Subscriber Management scenario on MX Series when a specifically malformed ICMP packet addressed to the device is received from a subscriber the bbe-smgd will crash, affecting the subscriber sessions that are connecting, updating, or terminating. Continued receipt of such packets will lead to a sustained DoS condition. When this issue happens the below log can be seen if the traceoptions for the processes smg-service are enabled: BBE_TRACE(TRACE_LEVEL_INFO, "%s: Dropped unsupported ICMP PKT ... This issue affects Juniper Networks Junos OS on MX Series: All versions prior to 19.4R3-S11; 20.2 versions prior to 20.2R3-S7; 20.3 versions prior to 20.3R3-S6; 20.4 versions prior to 20.4R3-S6; 21.1 versions prior to 21.1R3-S4; 21.2 versions prior to 21.2R3-S4; 21.3 versions prior to 21.3R3-S3; 21.4 versions prior to 21.4R3-S2; 22.1 versions prior to 22.1R2-S2, 22.1R3; 22.2 versions prior to 22.2R2; 22.3 versions prior to 22.3R1-S2, 22.3R2.
An Improper Check for Unusual or Exceptional Conditions vulnerability in BGP route processing of Juniper Networks Junos OS and Junos OS Evolved allows an attacker to cause Routing Protocol Daemon (RPD) crash by sending a BGP route with invalid next-hop resulting in a Denial of Service (DoS). Continued receipt and processing of this packet will create a sustained Denial of Service (DoS) condition. This issue only affects systems without import policy configured. This issue affects: Juniper Networks Junos OS 21.1 versions prior to 21.1R3-S4; 21.2 versions prior to 21.2R3-S3; 21.3 versions prior to 21.3R3-S2; 21.4 versions prior to 21.4R2-S2, 21.4R3; 22.1 versions prior to 22.1R1-S2, 22.1R2; 22.2 versions prior to 22.2R1-S1, 22.2R2. Juniper Networks Junos OS Evolved 21.4-EVO versions prior to 21.4R2-S2-EVO, 21.4R3-EVO; 22.1-EVO versions prior to 22.1R1-S2-EVO, 22.1R2-EVO; 22.2-EVO versions prior to 22.2R1-S1-EVO, 22.2R2-EVO. This issue does not affect: Juniper Networks Junos OS versions prior to 21.1R1. Juniper Networks Junos OS Evolved versions prior to 21.3R1-EVO.
An Improper Check for Unusual or Exceptional Conditions vulnerability in telemetry processing of Juniper Networks Junos OS and Junos OS Evolved allows a network-based authenticated attacker to cause the forwarding information base telemetry daemon (fibtd) to crash, leading to a limited Denial of Service. This issue affects Juniper Networks Junos OS: * from 22.1 before 22.1R1-S2, 22.1R2. Junos OS Evolved: * from 22.1 before 22.1R1-S2-EVO, 22.1R2-EVO.
An Improper Check for Unusual or Exceptional Conditions in Juniper Networks Junos OS Evolved may cause the stateless firewall filter configuration which uses the action 'policer' in certain combinations with other options to not take effect. An administrator can use the following CLI command to see the failures with filter configuration: user@device> show log kfirewall-agent.log | match ERROR Jul 23 14:16:03 ERROR: filter not supported This issue affects Juniper Networks Junos OS Evolved: Versions 19.1R1-EVO and above prior to 20.3R1-S2-EVO, 20.3R2-EVO. This issue does not affect Juniper Networks Junos OS.
When the "Intrusion Detection Service" (IDS) feature is configured on Juniper Networks MX series with a dynamic firewall filter using IPv6 source or destination prefix, it may incorrectly match the prefix as /32, causing the filter to block unexpected traffic. This issue affects only IPv6 prefixes when used as source and destination. This issue affects MX Series devices using MS-MPC, MS-MIC or MS-SPC3 service cards with IDS service configured. This issue affects: Juniper Networks Junos OS 17.3 versions prior to 17.3R3-S10 on MX Series; 17.4 versions prior to 17.4R3-S3 on MX Series; 18.1 versions prior to 18.1R3-S11 on MX Series; 18.2 versions prior to 18.2R3-S6 on MX Series; 18.3 versions prior to 18.3R3-S4 on MX Series; 18.4 versions prior to 18.4R3-S6 on MX Series; 19.1 versions prior to 19.1R2-S2, 19.1R3-S3 on MX Series; 19.2 versions prior to 19.2R3-S1 on MX Series; 19.3 versions prior to 19.3R2-S5, 19.3R3-S1 on MX Series; 19.4 versions prior to 19.4R3 on MX Series; 20.1 versions prior to 20.1R2 on MX Series; 20.2 versions prior to 20.2R2 on MX Series;
Due to an improper check for unusual or exceptional conditions in Juniper Networks Junos OS and Junos OS Evolved the Routing Protocol Daemon (RPD) service, upon receipt of a specific matching BGP packet meeting a specific term in the flowspec configuration, crashes and restarts causing a Denial of Service (DoS). Continued receipt and processing of this packet will create a sustained Denial of Service (DoS) condition. This issue affects only Multiprotocol BGP (MP-BGP) VPNv6 FlowSpec deployments. This issue affects: Juniper Networks Junos OS: 18.4 versions prior to 18.4R1-S8, 18.4R2-S7, 18.4R3-S7; 19.1 versions prior to 19.1R2-S2, 19.1R3-S4; 19.2 versions prior to 19.2R1-S6, 19.2R3-S2; 19.3 versions prior to 19.3R3-S2; 19.4 versions prior to 19.4R2-S4, 19.4R3-S1; 20.1 versions prior to 20.1R2, 20.1R3; 20.2 versions prior to 20.2R2, 20.2R3; 20.3 versions prior to 20.3R1-S1, 20.3R2. Juniper Networks Junos OS Evolved: All versions after 18.4R1-EVO prior to 20.3R2-EVO. This issue does not affect: Juniper Networks Junos OS versions prior to 18.4R1. Juniper Networks Junos OS Evolved versions prior to 18.4R1-EVO.
An Improper Access Control vulnerability in the User Interface (UI) of Juniper Networks Junos OS allows a local, low-privileged attacker to bring down an interface, leading to a Denial-of-Service. Users with "view" permissions can run a specific request interface command which allows the user to shut down the interface. This issue affects Junos OS: * All versions before 21.2R3-S9, * from 21.4 before 21.4R3-S11, * from 22.2 before 22.2R3-S7, * from 22.4 before 22.4R3-S7, * from 23.2 before 23.2R2-S4, * from 23.4 before 23.4R2-S5, * from 24.2 before 24.2R2-S1, * from 24.4 before 24.4R1-S3, 24.4R2.
An Improper Check for Unusual or Exceptional Conditions vulnerability in the flow processing daemon (flowd) of Juniper Networks Junos OS on SRX1600, SRX2300, SRX 4000 Series, and SRX5000 Series with SPC3 allows an unauthenticated, network-based attacker to cause a Denial-of-Service (DoS). If a sequence of specific PIM packets is received, this will cause a flowd crash and restart. This issue affects Junos OS: * all versions before 21.2R3-S9, * 21.4 versions before 21.4R3-S11, * 22.2 versions before 22.2R3-S7, * 22.4 versions before 22.4R3-S6, * 23.2 versions before 23.2R2-S4, * 23.4 versions before 23.4R2-S4, * 24.2 versions before 24.2R2. This is a similar, but different vulnerability than the issue reported as CVE-2024-47503, published in JSA88133.
An Improper Access Control vulnerability in the Juniper Networks Paragon Active Assurance Control Center allows an unauthenticated network-based attacker to access reports without authenticating, potentially containing sensitive configuration information. A feature was introduced in version 3.1.0 of the Paragon Active Assurance Control Center which allows users to selectively share account data. By exploiting this vulnerability, it is possible to access reports without being logged in, resulting in the opportunity for malicious exfiltration of user data. Note that the Paragon Active Assurance Control Center SaaS offering is not affected by this issue. This issue affects Juniper Networks Paragon Active Assurance versions 3.1.0, 3.2.0, 3.2.2, 3.3.0, 3.3.1, 3.4.0. This issue does not affect Juniper Networks Paragon Active Assurance versions earlier than 3.1.0.
An Improper Check for Unusual or Exceptional Conditions vulnerability in Routing Protocol Daemon (RPD) of Juniper Networks Junos OS and Junos OS Evolved allows a network-based, unauthenticated attacker to cause rpd to crash, leading to Denial of Service (DoS). On all Junos OS and Junos OS Evolved platforms, when NETCONF and gRPC are enabled, and a specific query is executed via Dynamic Rendering (DREND), rpd will crash and restart. Continuous execution of this specific query will cause a sustained Denial of Service (DoS) condition. This issue affects: Juniper Networks Junos OS * 22.2 versions earlier than 22.2R2-S2, 22.2R3; * 22.3 versions earlier than 22.3R2, 22.3R3. Juniper Networks Junos OS Evolved * 22.2 versions earlier than 22.2R2-S2-EVO, 22.2R3-EVO; * 22.3 versions earlier than 22.3R2-EVO, 22.3R3-EVO. This issue does not affect Juniper Networks: Junos OS versions earlier than 22.2R1; Junos OS Evolved versions earlier than 22.2R1-EVO.
An Improper Check for Unusual or Exceptional Conditions vulnerability in the kernel of Juniper Network Junos OS on MX Series allows a network based attacker with low privileges to cause a denial of service. If a scaled configuration for Source class usage (SCU) / destination class usage (DCU) (more than 10 route classes) is present and the SCU/DCU statistics are gathered by executing specific SNMP requests or CLI commands, a 'vmcore' for the RE kernel will be seen which leads to a device restart. Continued exploitation of this issue will lead to a sustained DoS. This issue only affects MX Series devices with MPC10, MPC11 or LC9600, and MX304. No other MX Series devices are affected. This issue affects Juniper Networks Junos OS: * All versions earlier than 20.4R3-S9; * 21.2 versions earlier than 21.2R3-S6; * 21.3 versions earlier than 21.3R3-S5; * 21.4 versions earlier than 21.4R3; * 22.1 versions earlier than 22.1R3; * 22.2 versions earlier than 22.2R2; * 22.3 versions earlier than 22.3R2.
A vulnerability in Juniper Networks Junos OS on SRX Series, allows a network-based unauthenticated attacker to cause a Denial of Service (DoS) by sending a specific fragmented packet to the device, resulting in a flowd process crash, which is responsible for packet forwarding. Continued receipt and processing of this specific packet will create a sustained DoS condition. This issue only affects SRX Series when 'preserve-incoming-fragment-size' feature is enabled. This issue affects Juniper Networks Junos OS on SRX Series: 18.3 versions prior to 18.3R3-S6; 18.4 versions prior to 18.4R3-S10; 19.1 versions prior to 19.1R3-S7; 19.2 versions prior to 19.2R3-S4; 19.3 versions prior to 19.3R3-S4; 19.4 versions prior to 19.4R3-S6; 20.1 versions prior to 20.1R3-S2; 20.2 versions prior to 20.2R3-S3; 20.3 versions prior to 20.3R3-S1; 20.4 versions prior to 20.4R3; 21.1 versions prior to 21.1R2-S1, 21.1R3; 21.2 versions prior to 21.2R2. This issue does not affect Juniper Networks Junos OS prior to 17.3R1.
An Improper Check for Unusual or Exceptional Conditions vulnerability in the Packet Forwarding Engine (PFE) of Juniper Networks Junos OS allows an adjacent unauthenticated attacker to cause a Denial of Service (DoS). The issue is caused by malformed MLD packets looping on a multi-homed Ethernet Segment Identifier (ESI) when VXLAN is configured. These MLD packets received on a multi-homed ESI are sent to the peer, and then incorrectly forwarded out the same ESI, violating the split horizon rule. This issue only affects QFX10K Series switches, including the QFX10002, QFX10008, and QFX10016. Other products and platforms are unaffected by this vulnerability. This issue affects Juniper Networks Junos OS on QFX10K Series: All versions prior to 19.1R3-S9; 19.2 versions prior to 19.2R1-S9, 19.2R3-S5; 19.3 versions prior to 19.3R3-S6; 19.4 versions prior to 19.4R2-S7, 19.4R3-S8; 20.1 versions prior to 20.1R3-S4; 20.2 versions prior to 20.2R3-S4; 20.3 versions prior to 20.3R3-S2; 20.4 versions prior to 20.4R3-S2; 21.1 versions prior to 21.1R3; 21.2 versions prior to 21.2R2-S1, 21.2R3; 21.3 versions prior to 21.3R2.
QFX and EX Series switches configured to drop traffic when the MAC move limit is exceeded will forward traffic instead of dropping traffic. This can lead to denials of services or other unintended conditions. Affected releases are Juniper Networks Junos OS: 14.1X53 versions prior to 14.1X53-D40; 15.1X53 versions prior to 15.1X53-D55; 15.1 versions prior to 15.1R7.
An Improper Check for Unusual or Exceptional Conditions vulnerability in the Routing Protocol Daemon (rpd) of Juniper Networks Junos OS and Junos OS Evolved allows a local, low-privileged attacker to cause a Denial-of-Service (DoS). When a specific "show bgp neighbor" CLI command is run, the rpd cpu utilization rises and eventually causes a crash and restart. Repeated use of this command will cause a sustained DoS condition. The device is only affected if BGP RIB sharding and update-threading is enabled. This issue affects Junos OS: * All versions before 21.2R3-S9, * from 21.4 before 21.4R3-S8, * from 22.2 before 22.2R3-S6, * from 22.4 before 22.4R3-S2, * from 23.2 before 23.2R2-S3, * from 23.4 before 23.4R2. and Junos OS Evolved: * All versions before 21.2R3-S9-EVO, * from 21.4-EVO before 21.4R3-S8-EVO, * from 22.2-EVO before 22.2R3-S6-EVO, * from 22.4-EVO before 22.4R3-S2-EVO, * from 23.2-EVO before 23.2R2-S3-EVO, * from 23.4-EVO before 23.4R2-EVO.
An Improper Check for Unusual or Exceptional Conditions vulnerability in the Packet Forwarding Engine (pfe) of Juniper Networks Junos OS on MX Series allows an unauthenticated, network-based attacker to cause a Denial-of-Service (DoS).When processing a high rate of specific GRE traffic destined to the device, the respective PFE will hang causing traffic forwarding to stop. When this issue occurs the following logs can be observed: <fpc #> MQSS(0): LI-3: Received a parcel with more than 512B accompanying data CHASSISD_FPC_ASIC_ERROR: ASIC Error detected <...> This issue affects Junos OS: * all versions before 21.2R3-S9, * 21.4 versions before 21.4R3-S8, * 22.2 versions before 22.2R3-S4, * 22.4 versions before 22.4R3-S5, * 23.2 versions before 23.2R2-S2, * 23.4 versions before 23.4R2.
An Improper Check for Unusual or Exceptional Conditions vulnerability in the Packet Forwarding Engine (PFE) of Juniper Networks Junos OS on SRX Series allows an unauthenticated, network-based, attacker to cause Denial of Service (DoS). A PFE crash will happen when a GPRS Tunnel Protocol (GTP) packet is received with a malformed field in the IP header of GTP encapsulated General Packet Radio Services (GPRS) traffic. The packet needs to match existing state which is outside the attackers control, so the issue cannot be directly exploited. The issue will only be observed when endpoint address validation is enabled. This issue affects Juniper Networks Junos OS on SRX Series: 20.2 versions prior to 20.2R3-S5; 20.3 versions prior to 20.3R3-S4; 20.4 versions prior to 20.4R3-S3; 21.1 versions prior to 21.1R3-S2; 21.2 versions prior to 21.2R3-S1; 21.3 versions prior to 21.3R3; 21.4 versions prior to 21.4R1-S2, 21.4R2; 22.1 versions prior to 22.1R1-S1, 22.1R2. This issue does not affect Juniper Networks Junos OS versions prior to 20.2R1.
An Improper Access Control vulnerability in Juniper Networks Junos OS Evolved allows a network-based unauthenticated attacker who is able to connect to a specific open IPv4 port, which in affected releases should otherwise be unreachable, to cause the CPU to consume all resources as more traffic is sent to the port to create a Denial of Service (DoS) condition. Continued receipt and processing of these packets will create a sustained Denial of Service (DoS) condition. This issue affects: Juniper Networks Junos OS Evolved 20.4 versions prior to 20.4R3-S2-EVO; 21.1 versions prior to 21.1R3-S1-EVO; 21.2 versions prior to 21.2R3-EVO; 21.3 versions prior to 21.3R2-EVO; 21.4 versions prior to 21.4R2-EVO. This issue does not affect Junos OS.
An Improper Check for Unusual or Exceptional Conditions vulnerability in the Packet Forwarding Engine (PFE) of Juniper Networks Junos OS allows an unauthenticated networked attacker to cause a Denial of Service (DoS) by sending specific packets over VXLAN which cause the PFE to reset. This issue affects: Juniper Networks Junos OS 19.4 versions prior to 19.4R3-S7; 20.1 versions prior to 20.1R3-S3; 20.2 versions prior to 20.2R3-S3; 20.3 versions prior to 20.3R3-S2; 20.4 versions prior to 20.4R3-S1; 21.1 versions prior to 21.1R3; 21.2 versions prior to 21.2R2; 21.3 versions prior to 21.3R1-S1, 21.3R2. This issue does not affect versions of Junos OS prior to 19.4R1.
A vulnerability in the processing of specific MPLS packets in Juniper Networks Junos OS on MX Series and EX9200 Series devices with Trio-based MPCs (Modular Port Concentrators) may cause FPC to crash and lead to a Denial of Service (DoS) condition. Continued receipt of this packet will sustain the Denial of Service (DoS) condition. This issue only affects MX Series and EX9200 Series with Trio-based PFEs (Packet Forwarding Engines). This issue affects Juniper Networks Junos OS on MX Series, EX9200 Series: 17.3 versions prior to 17.3R3-S12; 17.4 versions prior to 17.4R2-S13, 17.4R3-S5; 18.1 versions prior to 18.1R3-S13; 18.2 versions prior to 18.2R3-S8; 18.3 versions prior to 18.3R3-S5; 18.4 versions prior to 18.4R2-S8, 18.4R3-S8; 19.1 versions prior to 19.1R3-S5; 19.2 versions prior to 19.2R3-S2; 19.3 versions prior to 19.3R2-S6, 19.3R3-S3; 19.4 versions prior to 19.4R1-S4, 19.4R2-S4, 19.4R3-S2; 20.1 versions prior to 20.1R3; 20.2 versions prior to 20.2R2-S2, 20.2R3; 20.3 versions prior to 20.3R2; 20.4 versions prior to 20.4R2;
An Improper Access Control vulnerability in the Juniper Networks Paragon Active Assurance Control Center allows an unauthenticated attacker to leverage a crafted URL to generate PDF reports, potentially containing sensitive configuration information. A feature was introduced in version 3.1 of the Paragon Active Assurance Control Center which allows users to selective share account data using a unique identifier. Knowing the proper format of the URL and the identifier of an existing object in an application it is possible to get access to that object without being logged in, even if the object is not shared, resulting in the opportunity for malicious exfiltration of user data. Note that the Paragon Active Assurance Control Center SaaS offering is not affected by this issue. This issue affects Juniper Networks Paragon Active Assurance version 3.1.0.
An Improper Check for Unusual or Exceptional Conditions vulnerability in the Packet Forwarding Engine (PFE) of Juniper Networks Junos OS Evolved on ACX7000 Series allows an unauthenticated network-based attacker to cause a partial Denial of Service (DoS). On receipt of specific IPv6 transit traffic, Junos OS Evolved on ACX7100-48L, ACX7100-32C and ACX7509 sends this traffic to the Routing Engine (RE) instead of forwarding it, leading to increased CPU utilization of the RE and a partial DoS. This issue only affects systems configured with IPv6. This issue does not affect ACX7024 which is supported from 22.3R1-EVO onwards where the fix has already been incorporated as indicated in the solution section. This issue affects Juniper Networks Junos OS Evolved on ACX7100-48L, ACX7100-32C, ACX7509: 21.1-EVO versions prior to 21.1R3-S2-EVO; 21.2-EVO versions prior to 21.2R3-S2-EVO; 21.3-EVO versions prior to 21.3R3-EVO; 21.4-EVO versions prior to 21.4R1-S1-EVO, 21.4R2-EVO. This issue does not affect Juniper Networks Junos OS Evolved versions prior to 21.1R1-EVO.
An authentication bypass vulnerability in the Juniper Networks Paragon Active Assurance Control Center may allow an attacker with specific information about the deployment to mimic an already registered Test Agent and access its configuration including associated inventory details. If the issue occurs, the affected Test Agent will not be able to connect to the Control Center. This issue affects Juniper Networks Paragon Active Assurance Control Center All versions prior to 2.35.6; 2.36 versions prior to 2.36.2.
On SRX Series devices, an Improper Check for Unusual or Exceptional Conditions when using Certificate Management Protocol Version 2 (CMPv2) auto re-enrollment, allows a network-based, unauthenticated attacker to cause a Denial of Service (DoS) by crashing the pkid process. The pkid process cannot handle an unexpected response from the Certificate Authority (CA) server, leading to crash. A restart is required to restore services. This issue affects: Juniper Networks Junos OS on SRX Series: All versions prior to 19.1R3-S9; 19.2 versions prior to 19.2R3-S6; 19.3 versions prior to 19.3R3-S7; 19.4 versions prior to 19.4R3-S9; 20.2 versions prior to 20.2R3-S5; 20.3 versions prior to 20.3R3-S4; 20.4 versions prior to 20.4R3-S4; 21.1 versions prior to 21.1R3-S1; 21.2 versions prior to 21.2R3; 21.3 versions prior to 21.3R2; 21.4 versions prior to 21.4R2.
An Improper Check for Unusual or Exceptional Conditions vulnerability in the routing protocol daemon (rpd) of Juniper Networks Junos OS and Junos OS Evolved allows an unauthenticated, adjacent attacker to cause a Denial of Service (DoS). When an incoming RESV message corresponding to a protected LSP is malformed it causes an incorrect internal state resulting in an rpd core. This issue affects: Juniper Networks Junos OS All versions prior to 19.2R3-S6; 19.3 versions prior to 19.3R3-S6; 19.4 versions prior to 19.4R3-S8; 20.1 versions prior to 20.1R3-S2; 20.2 versions prior to 20.2R3-S3; 20.3 versions prior to 20.3R3-S2; 20.4 versions prior to 20.4R3-S1; 21.1 versions prior to 21.1R3; 21.2 versions prior to 21.2R1-S2, 21.2R3; 21.3 versions prior to 21.3R2. Juniper Networks Junos OS Evolved All versions prior to 20.2R3-S3-EVO; 20.3-EVO version 20.3R1-EVO and later versions; 20.4-EVO versions prior to 20.4R3-S1-EVO; 21.1-EVO version 21.1R1-EVO and later versions; 21.2-EVO version 21.2R1-EVO and later versions; 21.3-EVO versions prior to 21.3R2-EVO.
An Improper Check for Unusual or Exceptional Conditions vulnerability in the Routing Protocol Daemon (rpd) of Juniper Networks Junos OS and Junos OS Evolved allows an adjacent, unauthenticated attacker with an established ISIS adjacency to cause a Denial of Service (DoS). The rpd CPU spikes to 100% after a malformed ISIS TLV has been received which will lead to processing issues of routing updates and in turn traffic impact. This issue affects: Juniper Networks Junos OS 19.3 versions prior to 19.3R3-S4; 19.4 versions prior to 19.4R2-S6, 19.4R3-S6; 20.1 versions prior to 20.1R3-S2; 20.2 versions prior to 20.2R3-S3; 20.3 versions prior to 20.3R3-S1; 20.4 versions prior to 20.4R3; 21.1 versions prior to 21.1R3; 21.2 versions prior to 21.2R2. Juniper Networks Junos OS Evolved All versions prior to 20.4R3-S3-EVO; 21.2 versions prior to 21.2R2-EVO. This issue does not affect Juniper Networks Junos OS versions prior to 19.3R1.
An Improper Check for Unusual or Exceptional Conditions vulnerability in the processing of specific IPv6 packets on certain EX Series devices may lead to exhaustion of DMA memory causing a Denial of Service (DoS). Over time, exploitation of this vulnerability may cause traffic to stop being forwarded, or a crash of the fxpc process. An indication of the issue occurring may be observed through the following log messages: Sep 13 17:14:59 hostname : %PFE-3: fpc0 (buf alloc) failed allocating packet buffer Sep 13 17:14:59 hostname : %PFE-7: fpc0 brcm_pkt_buf_alloc:393 (buf alloc) failed allocating packet buffer When Packet DMA heap utilization reaches 99%, the system will become unstable. Packet DMA heap utilization can be monitored using the command: user@junos# request pfe execute target fpc0 timeout 30 command "show heap" ID Base Total(b) Free(b) Used(b) % Name -- ---------- ----------- ----------- ----------- --- ----------- 0 213301a8 536870488 387228840 149641648 27 Kernel 1 91800000 8388608 3735120 4653488 55 DMA 2 92000000 75497472 74452192 1045280 1 PKT DMA DESC 3 d330000 335544320 257091400 78452920 23 Bcm_sdk 4 96800000 184549376 2408 184546968 99 Packet DMA <<<< 5 903fffe0 20971504 20971504 0 0 Blob This issue affects: Juniper Networks Junos OS 18.4 versions prior to 18.4R2-S10, 18.4R3-S10 on EX2300 Series, EX2300-MP Series, EX3400 Series; 19.1 versions prior to 19.1R3-S7 on EX2300 Series, EX2300-MP Series, EX3400 Series; 19.2 versions prior to 19.2R1-S8, 19.2R3-S4 on EX2300 Series, EX2300-MP Series, EX3400 Series; 19.3 versions prior to 19.3R3-S5 on EX2300 Series, EX2300-MP Series, EX3400 Series; 19.4 versions prior to 19.4R3-S7 on EX2300 Series, EX2300-MP Series, EX3400 Series; 20.1 versions prior to 20.1R3-S3 on EX2300 Series, EX2300-MP Series, EX3400 Series; 20.2 versions prior to 20.2R3-S3 on EX2300 Series, EX2300-MP Series, EX3400 Series; 20.3 versions prior to 20.3R3-S2 on EX2300 Series, EX2300-MP Series, EX3400 Series; 20.4 versions prior to 20.4R3-S1 on EX2300 Series, EX2300-MP Series, EX3400 Series; 21.1 versions prior to 21.1R2-S2, 21.1R3 on EX2300 Series, EX2300-MP Series, EX3400 Series; 21.2 versions prior to 21.2R1-S2, 21.2R2 on EX2300 Series, EX2300-MP Series, EX3400 Series; 21.3 versions prior to 21.3R1-S1, 21.3R2 on EX2300 Series, EX2300-MP Series, EX3400 Series.
An Improper Check for Unusual or Exceptional Conditions vulnerability in the packetIO daemon of Juniper Networks Junos OS Evolved on PTX10003, PTX10004, and PTX10008 allows an unauthenticated, network-based attacker to cause a Denial of Service (DoS). Continued receipt of these crafted packets will cause a sustained Denial of Service condition. This issue affects Juniper Networks Junos OS Evolved all versions prior to 20.4R2-S3-EVO on PTX10003, PTX10004, and PTX10008. This issue does not affect: Juniper Networks Junos OS Evolved versions 21.1R1-EVO and above; Juniper Networks Junos OS.