This vulnerability allows remote attackers to execute arbitrary code on affected installations of D-Link DCS-960L v1.07.102. Authentication is not required to exploit this vulnerability. The specific flaw exists within the HNAP service, which listens on TCP port 80 by default. When parsing the SOAPAction request header, the process does not properly validate the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the admin user. Was ZDI-CAN-8458.
An issue discovered on D-Link DIR-615 devices with firmware version 20.05 and 20.07. wan.htm can be accessed directly without authentication, which can lead to disclosure of information about the WAN, and can also be leveraged by an attacker to modify the data fields of the page.
There are some web interfaces without authentication requirements on D-Link DIR-412 A1-1.14WW routers. An attacker can clear the router's log file via act=clear&logtype=sysact to log_clear.php, which could be used to erase attack traces.
D-Link DAP-1320 A2-V1.21 routers have some web interfaces without authentication requirements, as demonstrated by uplink_info.xml. An attacker can remotely obtain a user's Wi-Fi SSID and password, which could be used to connect to Wi-Fi or perform a dictionary attack.
D-Link DIR-822+ V1.0.2 contains a login bypass in the HNAP1 interface, which allows attackers to log in to administrator accounts with empty passwords.
There are some web interfaces without authentication requirements on D-Link DIR-412 A1-1.14WW routers. An attacker can get the router's log file via log_get.php, which could be used to discover the intranet network structure.
There are some web interfaces without authentication requirements on D-Link DIR-868L B1-2.03 and DIR-817LW A1-1.04 routers. An attacker can get the router's username and password (and other information) via a DEVICE.ACCOUNT value for SERVICES in conjunction with AUTHORIZED_GROUP=1%0a to getcfg.php. This could be used to control the router remotely.
D-Link DSL-2875AL devices through 1.00.05 are prone to password disclosure via a simple crafted /romfile.cfg request to the web management server. This request doesn't require any authentication and will lead to saving the configuration file. The password is stored in cleartext.
D-Link DAP-2622 DDP Set SSID List Missing Authentication Vulnerability. This vulnerability allows network-adjacent attackers to make unauthorized changes to device configuration on affected installations of D-Link DAP-2622 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the DDP service. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to manipulate wireless authentication settings. . Was ZDI-CAN-20104.
The D-Link DIR-816 A2 1.11 router only checks the random token when authorizing a goform request. An attacker can get this token from dir_login.asp and use an API URL /goform/LoadDefaultSettings to reset the router without authentication.
D-Link G416 httpd Missing Authentication for Critical Function Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of D-Link G416 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the HTTP service listening on TCP port 80. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to gain access to critical functions on the device. Was ZDI-CAN-21287.
An issue was discovered on D-Link DIR-600M 3.02, 3.03, 3.04, and 3.06 devices. wan.htm can be accessed directly without authentication, which can lead to disclosure of information about the WAN, and can also be leveraged by an attacker to modify the data fields of the page.
An issue was discovered on D-Link DSR-250N before 3.17B devices. The CGI script upgradeStatusReboot.cgi can be accessed without authentication. Any access reboots the device, rendering it therefore unusable for several minutes.
D-link DSL-2750U ISL2750UEME3.V1E devices allow approximately 90 seconds of access to the control panel, after a restart, before MAC address filtering rules become active.
Several web interfaces in D-Link DIR-868LW 1.12b have no authentication requirements for access, allowing for attackers to obtain users' DNS query history.
On D-Link DIR-823G 2018-09-19 devices, the GoAhead configuration allows /HNAP1 RunReboot commands without authentication to trigger a reboot.
An issue was discovered on D-Link DSL-2888A devices with firmware prior to AU_2.31_V1.1.47ae55. Lack of authentication functionality allows an attacker to assign a static IP address that was once used by a valid user.
An issue was discovered on D-Link DIR-816L devices 2.x before 1.10b04Beta02. There exists an exposed administration function in getcfg.php, which can be used to call various services. It can be utilized by an attacker to retrieve various sensitive information, such as admin login credentials, by setting the value of _POST_SERVICES in the query string to DEVICE.ACCOUNT.
An issue was discovered in /bin/goahead on D-Link DIR-823G devices with the firmware 1.02B03. There is incorrect access control allowing remote attackers to reset the router without authentication via the SetFactoryDefault HNAP API. Consequently, an attacker can achieve a denial-of-service attack without authentication.
In D-link DIR-816 A2_v1.10CNB04.img,the network can be reset without authentication via /goform/setMAC.
Missing authentication for critical function in DAP-1880AC firmware version 1.21 and earlier allows a remote attacker to login to the device as an authenticated user without the access privilege via unspecified vectors.
An issue was discovered on D-Link DSL-2640B B2 EU_4.01B devices. The device can be reset to its default configuration by accessing an unauthenticated URL.
An issue was discovered on Humax Digital HG100R 2.0.6 devices. To download the backup file it's not necessary to use credentials, and the router credentials are stored in plaintext inside the backup, aka GatewaySettings.bin.
An Improper Authorization issue was discovered in Sierra Wireless AirLink Raven XE, all versions prior to 4.0.14, and AirLink Raven XT, all versions prior to 4.0.11. Several files and directories can be accessed without authentication, which may allow a remote attacker to perform sensitive functions including arbitrary file upload, file download, and device reboot.
An issue was discovered in Veritas NetBackup 8.0 and earlier and NetBackup Appliance 3.0 and earlier. Unauthenticated CORBA interfaces permit inappropriate access.
An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Lack of authentication for remote service gives access to application set up and configuration.
Exploitation of Authentication vulnerability in the web interface in McAfee Advanced Threat Defense (ATD) 3.10, 3.8, 3.6, 3.4 allows remote unauthenticated users / remote attackers to bypass ATD detection via loose enforcement of authentication and authorization.
WiMAX routers based on the MediaTek SDK (libmtk) that use a custom httpd plugin are vulnerable to an authentication bypass allowing a remote, unauthenticated attacker to gain administrator access to the device by performing an administrator password change on the device via a crafted POST request.
ACTi cameras including the D, B, I, and E series using firmware version A1D-500-V6.11.31-AC fail to properly restrict access to the factory reset page. An unauthenticated, remote attacker can exploit this vulnerability by directly accessing the http://x.x.x.x/setup/setup_maintain_firmware-default.html page. This will allow an attacker to perform a factory reset on the device, leading to a denial of service condition or the ability to make use of default credentials (CVE-2017-3186).
Tad Uploader edit book list function is vulnerable to authorization bypass, thus remote attackers can use the function to amend the folder names in the book list without logging in.
Trustwave Secure Web Gateway (SWG) through 11.8.0.27 allows remote attackers to append an arbitrary public key to the device's SSH Authorized Keys data, and consequently obtain remote root access, via the publicKey parameter to the /sendKey URI.
A Missing Authentication for Critical Function issue was discovered in Schneider Electric InduSoft Web Studio v8.0 SP2 or prior, and InTouch Machine Edition v8.0 SP2 or prior. InduSoft Web Studio provides the capability for an HMI client to trigger script execution on the server for the purposes of performing customized calculations or actions. A remote malicious entity could bypass the server authentication and trigger the execution of an arbitrary command. The command is executed under high privileges and could lead to a complete compromise of the server.
The web administration server in Solar-Log 500 before 2.8.2 Build 52 does not require authentication, which allows remote attackers to gain administrative privileges by connecting to the server. As a result, the attacker can modify configuration files and change the system status. Fixed with 3.0.0-60 11.10.2013 for SL 200, 500, 1000 / not existing for SL 250, 300, 1200, 2000, SL 50 Gateway, SL Base.
Fresenius Kabi Agilia SP MC WiFi vD25 and prior has a default configuration page accessible without authentication. An attacker may use this functionality to change the exposed configuration values such as network settings.
A potential security vulnerability has been identified in HPE Application Performance Management (BSM) Platform versions 9.26, 9.30, 9.40. The vulnerability could be remotely exploited to allow code execution.
The Alcatel Lucent I-240W-Q GPON ONT using firmware version 3FE54567BOZJ19 allows a remote, unauthenticated attacker to enable telnetd on the router via a crafted HTTP request.
A Missing Authentication for Critical Function issue was discovered in OPW Fuel Management Systems SiteSentinel Integra 100, SiteSentinel Integra 500, and SiteSentinel iSite ATG consoles with the following software versions: older than V175, V175-V189, V191-V195, and V16Q3.1. An attacker may create an application user account to gain administrative privileges.
RouterOS versions 6.45.6 Stable, 6.44.5 Long-term, and below allow remote unauthenticated attackers to trigger DNS queries via port 8291. The queries are sent from the router to a server of the attacker's choice. The DNS responses are cached by the router, potentially resulting in cache poisoning
The Thrive Optimize WordPress plugin before 1.4.13.3, Thrive Comments WordPress plugin before 1.4.15.3, Thrive Headline Optimizer WordPress plugin before 1.3.7.3, Thrive Leads WordPress plugin before 2.3.9.4, Thrive Ultimatum WordPress plugin before 2.3.9.4, Thrive Quiz Builder WordPress plugin before 2.3.9.4, Thrive Apprentice WordPress plugin before 2.3.9.4, Thrive Visual Editor WordPress plugin before 2.6.7.4, Thrive Dashboard WordPress plugin before 2.3.9.3, Thrive Ovation WordPress plugin before 2.4.5, Thrive Clever Widgets WordPress plugin before 1.57.1 and Rise by Thrive Themes WordPress theme before 2.0.0, Ignition by Thrive Themes WordPress theme before 2.0.0, Luxe by Thrive Themes WordPress theme before 2.0.0, FocusBlog by Thrive Themes WordPress theme before 2.0.0, Minus by Thrive Themes WordPress theme before 2.0.0, Squared by Thrive Themes WordPress theme before 2.0.0, Voice WordPress theme before 2.0.0, Performag by Thrive Themes WordPress theme before 2.0.0, Pressive by Thrive Themes WordPress theme before 2.0.0, Storied by Thrive Themes WordPress theme before 2.0.0, Thrive Themes Builder WordPress theme before 2.2.4 register a REST API endpoint associated with Zapier functionality. While this endpoint was intended to require an API key in order to access, it was possible to access it by supplying an empty api_key parameter in vulnerable versions if Zapier was not enabled. Attackers could use this endpoint to add arbitrary data to a predefined option in the wp_options table.
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)
Missing authentication for critical function in SolarView Compact SV-CPT-MC310 prior to Ver.6.5 allows an attacker to alter the setting information without the access privileges via unspecified vectors.
A vulnerability in the web-based management interface of Cisco HyperFlex HX Data Platform could allow an unauthenticated, remote attacker to upload files to an affected device. This vulnerability is due to missing authentication for the upload function. An attacker could exploit this vulnerability by sending a specific HTTP request to an affected device. A successful exploit could allow the attacker to upload files to the affected device with the permissions of the tomcat8 user.
An issue was discovered on D-Link DSL-2640B E1 EU_1.01 devices. The administrative interface doesn't perform authentication checks for a firmware-update POST request. Any attacker that can access the administrative interface can install firmware of their choice.
Control Web Panel Missing Authentication Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Control Web Panel. Authentication is not required to exploit this vulnerability. The specific flaw exists within the implementation of authentication within the web interface. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to execute code in the context of a valid CWP user. Was ZDI-CAN-20582.
A vulnerability in the HTTPS proxy feature of Cisco Wide Area Application Services (WAAS) Software could allow an unauthenticated, remote attacker to use the Central Manager as an HTTPS proxy. The vulnerability is due to insufficient authentication of proxy connection requests. An attacker could exploit this vulnerability by sending a malicious HTTPS CONNECT message to the Central Manager. A successful exploit could allow the attacker to access public internet resources that would normally be blocked by corporate policies.
Intelbras WRN240 devices do not require authentication to replace the firmware via a POST request to the incoming/Firmware.cfg URI.
A vulnerability in the Virtual Network Computing (VNC) console implementation of Cisco Enterprise NFV Infrastructure Software (NFVIS) could allow an unauthenticated, remote attacker to access the VNC console session of an administrative user on an affected device. The vulnerability is due to an insufficient authentication mechanism used to establish a VNC session. An attacker could exploit this vulnerability by intercepting an administrator VNC session request prior to login. A successful exploit could allow the attacker to watch the administrator console session or interact with it, allowing admin access to the affected device.
On Signify Philips Taolight Smart Wi-Fi Wiz Connected LED Bulb 9290022656 devices, an unprotected API lets remote users control the bulb's operation. Anyone can turn the bulb on or off, or change its color or brightness remotely. There is no authentication or encryption to use the control API. The only requirement is that the attacker have network access to the bulb.
Functions/EWD_UFAQ_Import.php in the ultimate-faqs plugin through 1.8.24 for WordPress allows unauthenticated options import.
The udpServerSys service in Petwant PF-103 firmware 4.22.2.42 and Petalk AI 3.2.2.30 allows remote attackers to initiate firmware upgrades and alter device settings.