An issue was discovered on Humax Digital HG100 2.0.6 devices. The attacker can find the root credentials in the backup file, aka GatewaySettings.bin.
An issue was discovered on Humax Wireless Voice Gateway HGB10R-2 20160817_1855 devices. Admin credentials are sent over cleartext HTTP.
AOMEI Cyber Backup Missing Authentication for Critical Function Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of AOMEI Cyber Backup. Authentication is not required to exploit this vulnerability. The specific flaw exists within the StorageNode service, which listens on TCP port 9075 by default. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-26156.
AOMEI Cyber Backup Missing Authentication for Critical Function Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of AOMEI Cyber Backup. Authentication is not required to exploit this vulnerability. The specific flaw exists within the DaoService service, which listens on TCP port 9074 by default. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-26158.
Veeam Backup & Replication 10.x and 11.x has Incorrect Access Control (issue 1 of 2).
Arbitrary code execution vulnerability on Micro Focus Operation Bridge Reporter, affecting version 10.40 and earlier. The vulnerability could allow remote attackers to execute arbitrary code on affected installations of OBR.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the control service, which listens on TCP port 9999 by default. The issue results from the lack of authentication prior to allowing alterations to the system configuration. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-10493.
This vulnerability allows remote attackers to issue commands on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the EA-HTTP.exe process. The issue results from the lack of authentication prior to allowing alterations to the system configuration. An attacker can leverage this vulnerability to issue commands to the physical equipment controlled by the device. Was ZDI-CAN-10482.
Emerson OpenEnterprise versions through 3.3.4 may allow an attacker to run an arbitrary commands with system privileges or perform remote code execution via a specific communication service.
The Micro Air Vehicle Link (MAVLink) protocol presents no authentication mechanism on its version 1.0 (nor authorization) whichs leads to a variety of attacks including identity spoofing, unauthorized access, PITM attacks and more. According to literature, version 2.0 optionally allows for package signing which mitigates this flaw. Another source mentions that MAVLink 2.0 only provides a simple authentication system based on HMAC. This implies that the flying system overall should add the same symmetric key into all devices of network. If not the case, this may cause a security issue, that if one of the devices and its symmetric key are compromised, the whole authentication system is not reliable.
MiR100, MiR200 and other MiR robots use the Robot Operating System (ROS) default packages exposing the computational graph without any sort of authentication. This allows attackers with access to the internal wireless and wired networks to take control of the robot seamlessly. In combination with CVE-2020-10269 and CVE-2020-10271, this flaw allows malicious actors to command the robot at desire.
HPE Data Protector before 7.03_108, 8.x before 8.15, and 9.x before 9.06 allow remote attackers to execute arbitrary code via unspecified vectors related to lack of authentication. NOTE: this vulnerability exists because of an incomplete fix for CVE-2014-2623.
eQ-3 Homematic CCU2 prior to 2.47.10 and CCU3 prior to 3.47.10 JSON API has Improper Access Control for Interface.***Metadata related operations, resulting in the ability to read, set and deletion of Metadata.
The root password of the Cobham EXPLORER 710 is the same for all versions of firmware up to and including v1.08. This could allow an attacker to reverse-engineer the password from available versions to gain authenticated access to the device.
The WPGraphQL 0.2.3 plugin for WordPress allows remote attackers to register a new user with admin privileges, whenever new user registrations are allowed. This is related to the registerUser mutation.
Jector Smart TV FM-K75 devices allow remote code execution because there is an adb open port with root permission.
In several versions of JetBrains IntelliJ IDEA Ultimate, creating Task Servers configurations leads to saving a cleartext unencrypted record of the server credentials in the IDE configuration files. The issue has been fixed in the following versions: 2019.1, 2018.3.5, 2018.2.8, and 2018.1.8.
In several JetBrains IntelliJ IDEA versions, creating remote run configurations of JavaEE application servers leads to saving a cleartext record of the server credentials in the IDE configuration files. The issue has been fixed in the following versions: 2018.3.5, 2018.2.8, 2018.1.8.
In IOBit IOTransfer 4.3.1.1561, an unauthenticated attacker can send GET and POST requests to Airserv and gain arbitrary read/write access to the entire file-system (with admin privileges) on the victim's endpoint, which can result in data theft and remote code execution.
An issue was discovered on D-Link DIR-878 1.12B01 devices. Because strncpy is misused, there is a stack-based buffer overflow vulnerability that does not require authentication via the HNAP_AUTH HTTP header.
NUUO NVRmini2 through 3.11 allows an unauthenticated attacker to upload an encrypted TAR archive, which can be abused to add arbitrary users because of the lack of handle_import_user.php authentication. When combined with another flaw (CVE-2011-5325), it is possible to overwrite arbitrary files under the web root and achieve code execution as root.
An issue was discovered on Moxa MGate MB3170 and MB3270 devices before 4.1, MB3280 and MB3480 devices before 3.1, MB3660 devices before 2.3, and MB3180 devices before 2.1. The application's configuration file contains parameters that represent passwords in cleartext.
On Netis WF2411 with firmware 2.1.36123 and other Netis WF2xxx devices (possibly WF2411 through WF2880), there is a stack-based buffer overflow that does not require authentication. This can cause denial of service (device restart) or remote code execution. This vulnerability can be triggered by a GET request with a long HTTP "Authorization: Basic" header that is mishandled by user_auth->user_ok in /bin/boa.
An issue was discovered on Shenzhen Coship WM3300 WiFi Router 5.0.0.55 devices. The password reset functionality of the Wireless SSID doesn't require any type of authentication. By making a POST request to the regx/wireless/wl_security_2G.asp URI, the attacker can change the password of the Wi-FI network.
Nortek Linear eMerge 50P/5000P devices have Default Credentials.
Linear eMerge E3-Series devices have Cleartext Credentials in a Database.
A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The RCP+ network port allows access without authentication. Adding authentication feature to the respective library fixes the issue. The issue is classified as "CWE-284: Improper Access Control." This vulnerability, for example, allows a potential attacker to delete video or read video data.
In NICE Engage through 6.5, the default configuration binds an unauthenticated JMX/RMI interface to all network interfaces, without restricting registration of MBeans, which allows remote attackers to execute arbitrary code via the RMI protocol by using the JMX connector. The observed affected TCP port is 6338 but, based on the product's configuration, a different one could be vulnerable.
An issue was discovered in portier vision 4.4.4.2 and 4.4.4.6. Passwords are stored using reversible encryption rather than as a hash value, and the used Vigenere algorithm is badly outdated. Moreover, the encryption key is static and too short. Due to this, the passwords stored by the application can be easily decrypted.
AVEVA Software, LLC InduSoft Web Studio prior to Version 8.1 SP3 and InTouch Edge HMI (formerly InTouch Machine Edition) prior to Version 2017 Update. Code is executed under the program runtime privileges, which could lead to the compromise of the machine.
The telnet daemon (telnetd) in MIT krb5 before 1.6.1 allows remote attackers to bypass authentication and gain system access via a username beginning with a '-' character, a similar issue to CVE-2007-0882.
An issue was discovered on D-Link DAP-1360 revision F devices. Remote attackers can start a telnet service without authorization via an undocumented HTTP request. Although this is the primary vulnerability, the impact depends on the firmware version. Versions 609EU through 613EUbeta were tested. Versions through 6.12b01 have weak root credentials, allowing an attacker to gain remote root access. After 6.12b01, the root credentials were changed but the telnet service can still be started without authorization.
There are some web interfaces without authentication requirements on D-Link DIR-868L B1-2.03 and DIR-817LW A1-1.04 routers. An attacker can get the router's username and password (and other information) via a DEVICE.ACCOUNT value for SERVICES in conjunction with AUTHORIZED_GROUP=1%0a to getcfg.php. This could be used to control the router remotely.
Due to unencrypted and unauthenticated data communication, the wireless barcode scanner Inateck BCST-60 is prone to keystroke injection attacks. Thus, an attacker is able to send arbitrary keystrokes to a victim's computer system, e.g., to install malware when the target system is unattended. In this way, an attacker can remotely take control over the victim's computer that is operated with an affected receiver of this device.
An issue was discovered on Weidmueller IE-SW-VL05M 3.6.6 Build 16102415, IE-SW-VL08MT 3.5.2 Build 16102415, and IE-SW-PL10M 3.3.16 Build 16102416 devices. Sensitive Credentials data is transmitted in cleartext.
The HTTP client in Gradle before 5.6 sends authentication credentials originally destined for the configured host. If that host returns a 30x redirect, Gradle also sends those credentials to all subsequent hosts that the request redirects to. This is similar to CVE-2018-1000007.
In Totolink A3100R V5.9c.4577, multiple pages can be read by curl or Burp Suite without authentication. Additionally, admin configurations can be set without cookies.
Directus 7 API before 2.2.2 has insufficient anti-automation, as demonstrated by lack of a CAPTCHA in core/Directus/Services/AuthService.php and endpoints/Auth.php.
A broken access control vulnerability in Smart Battery A4, a multifunctional portable charger, firmware version ?<= r1.7.9 allows an attacker to get/reset administrator’s password without any authentication.
In ONAP MSB through Dublin, by accessing an applicable port (30234, 30290, 32010, 30270, 30224, 30281, 30254, 30285, and/or 30271), an attacker gains full access to the respective ONAP services without any authentication. All ONAP Operations Manager (OOM) setups are affected.
An Incorrect Access Control vulnerability was found in Wikimedia MediaWiki 1.27.0 through 1.32.1. Directly POSTing to Special:ChangeEmail would allow for bypassing re-authentication, allowing for potential account takeover.
Improper Access Control in the RCP+ server of the Bosch Video Recording Manager (VRM) component allows arbitrary and unauthenticated access to a limited subset of certificates, stored in the underlying Microsoft Windows operating system. The fixed versions implement modified authentication checks. Prior releases of VRM software version 3.70 are considered unaffected. This vulnerability affects VRM v3.70.x, v3.71 < v3.71.0034 and v3.81 < 3.81.0050; DIVAR IP 5000 3.80 < 3.80.0039; BVMS all versions using VRM.
In ONAP SO through Dublin, by accessing an applicable port (30234, 30290, 32010, 30270, 30224, 30281, 30254, 30285, and/or 30271), an attacker gains full access to the respective ONAP services without any authentication. All ONAP Operations Manager (OOM) setups are affected.
Missing Authentication for Critical Function vulnerability in debug_post_set.cgi of D-Link DWR-932C E1 firmware allows an unauthenticated attacker to execute administrative actions.
An issue was discovered in upgrade_firmware.cgi on VStarcam 100T (C7824WIP) CH-sys-48.53.75.119~123 and 200V (C38S) CH-sys-48.53.203.119~123 devices. A remote command can be executed through a system firmware update without authentication. The attacker can modify the files within the internal firmware or even steal account information by executing a command.
Anviz Global M3 Outdoor RFID Access Control executes any command received from any source. No authentication/encryption is done. Attackers can fully interact with the device: for example, send the "open door" command, download the users list (which includes RFID codes and passcodes in cleartext), or update/create users. The same attack can be executed on a local network and over the internet (if the device is exposed on a public IP address).
Fujifilm FCR Capsula X/ Carbon X/ FCR XC-2, model versions CR-IR 357 FCR Carbon X, CR-IR 357 FCR XC-2, FCR-IR 357 FCR Capsula X provide insecure telnet services that lack authentication requirements. An attacker who successfully exploits this vulnerability may be able to access the underlying operating system.
CloudBees Jenkins Operations Center 2.150.2.3, when an expired trial license exists, allows Cleartext Password Storage and Retrieval via the proxy configuration page.
An issue was discovered in AUO Solar Data Recorder before 1.3.0. The web portal uses HTTP Basic Authentication and provides the account and password in the WWW-Authenticate attribute. By using this account and password, anyone can login successfully.
A vulnerability in Veeam ONE allows an unprivileged user who has access to the Veeam ONE Web Client the ability to acquire the NTLM hash of the account used by the Veeam ONE Reporting Service.