Summary
Assigner-siemens
Assigner Org ID-cec7a2ec-15b4-4faf-bd53-b40f371f3a77
Published At-14 May, 2019 | 19:54
Updated At-04 Aug, 2024 | 22:40
Rejected At-
Credits

A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Unencrypted storage of passwords in the project could allow an attacker with access to port 10005/tcp to obtain passwords of the device. The security vulnerability could be exploited by an unauthenticated attacker with network access to port 10005/tcp. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:siemens
Assigner Org ID:cec7a2ec-15b4-4faf-bd53-b40f371f3a77
Published At:14 May, 2019 | 19:54
Updated At:04 Aug, 2024 | 22:40
Rejected At:
▼CVE Numbering Authority (CNA)

A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Unencrypted storage of passwords in the project could allow an attacker with access to port 10005/tcp to obtain passwords of the device. The security vulnerability could be exploited by an unauthenticated attacker with network access to port 10005/tcp. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known

Affected Products
Vendor
Siemens AGSiemens
Product
LOGO! 8 BM (incl. SIPLUS variants)
Versions
Affected
  • All versions < V8.3
Problem Types
TypeCWE IDDescription
CWECWE-256CWE-256: Unprotected Storage of Credentials
Type: CWE
CWE ID: CWE-256
Description: CWE-256: Unprotected Storage of Credentials
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
http://www.securityfocus.com/bid/108382
vdb-entry
x_refsource_BID
https://seclists.org/bugtraq/2019/May/74
mailing-list
x_refsource_BUGTRAQ
http://seclists.org/fulldisclosure/2019/May/49
mailing-list
x_refsource_FULLDISC
https://cert-portal.siemens.com/productcert/pdf/ssa-542701.pdf
x_refsource_MISC
http://packetstormsecurity.com/files/153124/Siemens-LOGO-8-Recoverable-Password-Format.html
x_refsource_MISC
Hyperlink: http://www.securityfocus.com/bid/108382
Resource:
vdb-entry
x_refsource_BID
Hyperlink: https://seclists.org/bugtraq/2019/May/74
Resource:
mailing-list
x_refsource_BUGTRAQ
Hyperlink: http://seclists.org/fulldisclosure/2019/May/49
Resource:
mailing-list
x_refsource_FULLDISC
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-542701.pdf
Resource:
x_refsource_MISC
Hyperlink: http://packetstormsecurity.com/files/153124/Siemens-LOGO-8-Recoverable-Password-Format.html
Resource:
x_refsource_MISC
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
http://www.securityfocus.com/bid/108382
vdb-entry
x_refsource_BID
x_transferred
https://seclists.org/bugtraq/2019/May/74
mailing-list
x_refsource_BUGTRAQ
x_transferred
http://seclists.org/fulldisclosure/2019/May/49
mailing-list
x_refsource_FULLDISC
x_transferred
https://cert-portal.siemens.com/productcert/pdf/ssa-542701.pdf
x_refsource_MISC
x_transferred
http://packetstormsecurity.com/files/153124/Siemens-LOGO-8-Recoverable-Password-Format.html
x_refsource_MISC
x_transferred
Hyperlink: http://www.securityfocus.com/bid/108382
Resource:
vdb-entry
x_refsource_BID
x_transferred
Hyperlink: https://seclists.org/bugtraq/2019/May/74
Resource:
mailing-list
x_refsource_BUGTRAQ
x_transferred
Hyperlink: http://seclists.org/fulldisclosure/2019/May/49
Resource:
mailing-list
x_refsource_FULLDISC
x_transferred
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-542701.pdf
Resource:
x_refsource_MISC
x_transferred
Hyperlink: http://packetstormsecurity.com/files/153124/Siemens-LOGO-8-Recoverable-Password-Format.html
Resource:
x_refsource_MISC
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:productcert@siemens.com
Published At:14 May, 2019 | 20:29
Updated At:04 Jan, 2022 | 18:11

A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Unencrypted storage of passwords in the project could allow an attacker with access to port 10005/tcp to obtain passwords of the device. The security vulnerability could be exploited by an unauthenticated attacker with network access to port 10005/tcp. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.17.5HIGH
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Primary2.05.0MEDIUM
AV:N/AC:L/Au:N/C:P/I:N/A:N
Type: Primary
Version: 3.1
Base score: 7.5
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Type: Primary
Version: 2.0
Base score: 5.0
Base severity: MEDIUM
Vector:
AV:N/AC:L/Au:N/C:P/I:N/A:N
CPE Matches

Siemens AG
siemens
>>logo\!8_bm_firmware>>Versions before 8.3(exclusive)
cpe:2.3:o:siemens:logo\!8_bm_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>logo\!8_bm>>*
cpe:2.3:h:siemens:logo\!8_bm:*:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-256Primaryproductcert@siemens.com
CWE-522Secondarynvd@nist.gov
CWE ID: CWE-256
Type: Primary
Source: productcert@siemens.com
CWE ID: CWE-522
Type: Secondary
Source: nvd@nist.gov
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
http://packetstormsecurity.com/files/153124/Siemens-LOGO-8-Recoverable-Password-Format.htmlproductcert@siemens.com
Exploit
Third Party Advisory
VDB Entry
http://seclists.org/fulldisclosure/2019/May/49productcert@siemens.com
Exploit
Mailing List
Third Party Advisory
http://www.securityfocus.com/bid/108382productcert@siemens.com
Third Party Advisory
VDB Entry
https://cert-portal.siemens.com/productcert/pdf/ssa-542701.pdfproductcert@siemens.com
Vendor Advisory
https://seclists.org/bugtraq/2019/May/74productcert@siemens.com
Exploit
Mailing List
Third Party Advisory
Hyperlink: http://packetstormsecurity.com/files/153124/Siemens-LOGO-8-Recoverable-Password-Format.html
Source: productcert@siemens.com
Resource:
Exploit
Third Party Advisory
VDB Entry
Hyperlink: http://seclists.org/fulldisclosure/2019/May/49
Source: productcert@siemens.com
Resource:
Exploit
Mailing List
Third Party Advisory
Hyperlink: http://www.securityfocus.com/bid/108382
Source: productcert@siemens.com
Resource:
Third Party Advisory
VDB Entry
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-542701.pdf
Source: productcert@siemens.com
Resource:
Vendor Advisory
Hyperlink: https://seclists.org/bugtraq/2019/May/74
Source: productcert@siemens.com
Resource:
Exploit
Mailing List
Third Party Advisory

Change History

0
Information is not available yet

Similar CVEs

458Records found

CVE-2020-25235
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.31% / 53.77%
||
7 Day CHG~0.00%
Published-14 Dec, 2020 | 21:05
Updated-04 Aug, 2024 | 15:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). The password used for authentication for the LOGO! Website and the LOGO! Access Tool is sent in a recoverable format. An attacker with access to the network traffic could derive valid logins.

Action-Not Available
Vendor-Siemens AG
Product-logo\!_8_bmlogo\!_8_bm_firmwareLOGO! 8 BM (incl. SIPLUS variants)
CWE ID-CWE-522
Insufficiently Protected Credentials
CVE-2022-27241
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.54% / 66.98%
||
7 Day CHG~0.00%
Published-12 Apr, 2022 | 09:08
Updated-03 Aug, 2024 | 05:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.31), Mendix Applications using Mendix 8 (All versions < V8.18.18), Mendix Applications using Mendix 9 (All versions < V9.11), Mendix Applications using Mendix 9 (V9.6) (All versions < V9.6.12). Applications built with an affected system publicly expose the internal project structure. This could allow an unauthenticated remote attacker to read confidential information.

Action-Not Available
Vendor-mendixSiemens AG
Product-mendixMendix Applications using Mendix 7Mendix Applications using Mendix 9 (V9.6)Mendix Applications using Mendix 8Mendix Applications using Mendix 9
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2024-54089
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.04% / 13.45%
||
7 Day CHG~0.00%
Published-11 Feb, 2025 | 10:29
Updated-12 Feb, 2025 | 15:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in APOGEE PXC Series (BACnet) (All versions), APOGEE PXC Series (P2 Ethernet) (All versions), TALON TC Series (BACnet) (All versions). Affected devices contain a weak encryption mechanism based on a hard-coded key. This could allow an attacker to guess or decrypt the password from the cyphertext.

Action-Not Available
Vendor-Siemens AG
Product-APOGEE PXC Series (P2 Ethernet)APOGEE PXC Series (BACnet)TALON TC Series (BACnet)
CWE ID-CWE-326
Inadequate Encryption Strength
CVE-2021-22918
Matching Score-8
Assigner-HackerOne
ShareView Details
Matching Score-8
Assigner-HackerOne
CVSS Score-5.3||MEDIUM
EPSS-0.72% / 72.00%
||
7 Day CHG~0.00%
Published-12 Jul, 2021 | 00:00
Updated-30 Apr, 2025 | 22:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Node.js before 16.4.1, 14.17.2, 12.22.2 is vulnerable to an out-of-bounds read when uv__idna_toascii() is used to convert strings to ASCII. The pointer p is read and increased without checking whether it is beyond pe, with the latter holding a pointer to the end of the buffer. This can lead to information disclosures or crashes. This function can be triggered via uv_getaddrinfo().

Action-Not Available
Vendor-Node.js (OpenJS Foundation)Siemens AG
Product-sinec_infrastructure_network_servicesnode.jsNode
CWE ID-CWE-125
Out-of-bounds Read
CVE-2021-22925
Matching Score-8
Assigner-HackerOne
ShareView Details
Matching Score-8
Assigner-HackerOne
CVSS Score-5.3||MEDIUM
EPSS-0.42% / 61.63%
||
7 Day CHG~0.00%
Published-05 Aug, 2021 | 00:00
Updated-03 Aug, 2024 | 18:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

curl supports the `-t` command line option, known as `CURLOPT_TELNETOPTIONS`in libcurl. This rarely used option is used to send variable=content pairs toTELNET servers.Due to flaw in the option parser for sending `NEW_ENV` variables, libcurlcould be made to pass on uninitialized data from a stack based buffer to theserver. Therefore potentially revealing sensitive internal information to theserver using a clear-text network protocol.This could happen because curl did not call and use sscanf() correctly whenparsing the string provided by the application.

Action-Not Available
Vendor-n/aNetApp, Inc.Oracle CorporationSiemens AGSplunk LLC (Cisco Systems, Inc.)Apple Inc.CURLFedora Project
Product-h300epeoplesoft_enterprise_peopletoolsh500scloud_backuph300s_firmwareh410smacoscurlh300suniversal_forwardersolidfiresinec_infrastructure_network_servicesh300e_firmwareclustered_data_ontapsinema_remote_connect_serverh500ehci_management_nodeh410s_firmwarefedorah500s_firmwaremac_os_xh500e_firmwareh700s_firmwareh700eh700e_firmwareh700smysql_serverhttps://github.com/curl/curl
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CWE ID-CWE-908
Use of Uninitialized Resource
CVE-2019-15681
Matching Score-8
Assigner-Kaspersky
ShareView Details
Matching Score-8
Assigner-Kaspersky
CVSS Score-7.5||HIGH
EPSS-6.19% / 90.64%
||
7 Day CHG~0.00%
Published-29 Oct, 2019 | 16:04
Updated-05 Aug, 2024 | 00:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

LibVNC commit before d01e1bb4246323ba6fcee3b82ef1faa9b1dac82a contains a memory leak (CWE-655) in VNC server code, which allow an attacker to read stack memory and can be abused for information disclosure. Combined with another vulnerability, it can be used to leak stack memory and bypass ASLR. This attack appear to be exploitable via network connectivity. These vulnerabilities have been fixed in commit d01e1bb4246323ba6fcee3b82ef1faa9b1dac82a.

Action-Not Available
Vendor-libvnc_projectDebian GNU/LinuxSiemens AGCanonical Ltd.Kaspersky Lab
Product-simatic_itc1500_pro_firmwareubuntu_linuxdebian_linuxsimatic_itc1500_prosimatic_itc1500simatic_itc1900simatic_itc1900_firmwaresimatic_itc1900_pro_firmwaresimatic_itc1500_firmwaresimatic_itc2200_firmwaresimatic_itc2200_prosimatic_itc2200_pro_firmwarelibvncserversimatic_itc1900_prosimatic_itc2200LibVNC
CWE ID-CWE-665
Improper Initialization
CVE-2023-23835
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-5.9||MEDIUM
EPSS-0.03% / 7.65%
||
7 Day CHG~0.00%
Published-14 Feb, 2023 | 10:36
Updated-20 Mar, 2025 | 16:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.34), Mendix Applications using Mendix 8 (All versions < V8.18.23), Mendix Applications using Mendix 9 (All versions < V9.22.0), Mendix Applications using Mendix 9 (V9.12) (All versions < V9.12.10), Mendix Applications using Mendix 9 (V9.18) (All versions < V9.18.4), Mendix Applications using Mendix 9 (V9.6) (All versions < V9.6.15). Some of the Mendix runtime API’s allow attackers to bypass XPath constraints and retrieve information using XPath queries that trigger errors.

Action-Not Available
Vendor-mendixSiemens AG
Product-mendixMendix Applications using Mendix 7Mendix Applications using Mendix 8Mendix Applications using Mendix 9Mendix Applications using Mendix 9 (V9.18)Mendix Applications using Mendix 9 (V9.12)Mendix Applications using Mendix 9 (V9.6)
CWE ID-CWE-284
Improper Access Control
CVE-2021-22946
Matching Score-8
Assigner-HackerOne
ShareView Details
Matching Score-8
Assigner-HackerOne
CVSS Score-7.5||HIGH
EPSS-0.07% / 21.58%
||
7 Day CHG~0.00%
Published-29 Sep, 2021 | 00:00
Updated-03 Aug, 2024 | 18:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A user can tell curl >= 7.20.0 and <= 7.78.0 to require a successful upgrade to TLS when speaking to an IMAP, POP3 or FTP server (`--ssl-reqd` on the command line or`CURLOPT_USE_SSL` set to `CURLUSESSL_CONTROL` or `CURLUSESSL_ALL` withlibcurl). This requirement could be bypassed if the server would return a properly crafted but perfectly legitimate response.This flaw would then make curl silently continue its operations **withoutTLS** contrary to the instructions and expectations, exposing possibly sensitive data in clear text over the network.

Action-Not Available
Vendor-n/aNetApp, Inc.Debian GNU/LinuxOracle CorporationSiemens AGSplunk LLC (Cisco Systems, Inc.)Apple Inc.CURLFedora Project
Product-peoplesoft_enterprise_peopletoolscommunications_cloud_native_core_consolecommunications_cloud_native_core_network_function_cloud_native_environmentcloud_backuph300s_firmwareh410smacoscurlh300ssolidfire_baseboard_management_controllersnapcenterh300e_firmwaresinec_infrastructure_network_servicesclustered_data_ontaph500efedorah500s_firmwareh500e_firmwarecommunications_cloud_native_core_binding_support_functionh700eoncommand_insighth300ecommunications_cloud_native_core_service_communication_proxycommunications_cloud_native_core_network_slice_selection_functioncommunications_cloud_native_core_security_edge_protection_proxyh500scommunications_cloud_native_core_network_repository_functiononcommand_workflow_automationuniversal_forwarderdebian_linuxh410s_firmwareh700s_firmwareh700e_firmwaresolidfire_baseboard_management_controller_firmwareh700scommerce_guided_searchmysql_serverhttps://github.com/curl/curl
CWE ID-CWE-325
Missing Cryptographic Step
CWE ID-CWE-319
Cleartext Transmission of Sensitive Information
CVE-2019-13941
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.47% / 63.98%
||
7 Day CHG~0.00%
Published-11 Feb, 2020 | 15:36
Updated-05 Aug, 2024 | 00:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in OZW672 (All versions < V10.00), OZW772 (All versions < V10.00). Vulnerable versions of OZW Web Server use predictable path names for project files that legitimately authenticated users have created by using the application's export function. By accessing a specific uniform resource locator on the web server, a remote attacker could be able to download a project file without prior authentication. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected system. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises the confidentiality of the targeted system.

Action-Not Available
Vendor-Siemens AG
Product-ozw672_firmwareozw772ozw772_firmwareozw672OZW772OZW672
CWE ID-CWE-552
Files or Directories Accessible to External Parties
CVE-2021-22876
Matching Score-8
Assigner-HackerOne
ShareView Details
Matching Score-8
Assigner-HackerOne
CVSS Score-5.3||MEDIUM
EPSS-0.07% / 20.78%
||
7 Day CHG~0.00%
Published-01 Apr, 2021 | 17:45
Updated-09 Jun, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

curl 7.1.1 to and including 7.75.0 is vulnerable to an "Exposure of Private Personal Information to an Unauthorized Actor" by leaking credentials in the HTTP Referer: header. libcurl does not strip off user credentials from the URL when automatically populating the Referer: HTTP request header field in outgoing HTTP requests, and therefore risks leaking sensitive data to the server that is the target of the second HTTP request.

Action-Not Available
Vendor-n/aNetApp, Inc.Fedora ProjectDebian GNU/LinuxOracle CorporationSplunk LLC (Cisco Systems, Inc.)Broadcom Inc.CURLSiemens AG
Product-hci_compute_nodedebian_linuxsinec_infrastructure_network_servicesfabric_operating_systemsolidfireessbasehci_management_nodeuniversal_forwardercommunications_billing_and_revenue_managementfedorahci_storage_nodelibcurlhttps://github.com/curl/curl
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CWE ID-CWE-359
Exposure of Private Personal Information to an Unauthorized Actor
CVE-2019-13944
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-5.3||MEDIUM
EPSS-0.26% / 48.66%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-05 Aug, 2024 | 00:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in EN100 Ethernet module DNP3 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.37), EN100 Ethernet module IEC104 variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). A vulnerability in the integrated web server of the affected devices could allow unauthorized attackers to obtain sensitive information about the device, including logs and configurations. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-en100_ethernet_module_with_firmware_variant_profinet_ioen100_ethernet_module_with_firmware_variant_modbus_tcpen100_ethernet_module_with_firmware_variant_iec_61850en100_ethernet_module_with_firmware_variant_dnp3_tcpen100_ethernet_module_with_firmware_variant_iec104en100_ethernet_moduleEN100 Ethernet module PROFINET IO variantEN100 Ethernet module DNP3 variantEN100 Ethernet module IEC104 variantEN100 Ethernet module Modbus TCP variantEN100 Ethernet module IEC 61850 variant
CWE ID-CWE-23
Relative Path Traversal
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2019-12265
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-5.3||MEDIUM
EPSS-12.87% / 93.87%
||
7 Day CHG~0.00%
Published-09 Aug, 2019 | 18:14
Updated-04 Aug, 2024 | 23:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Wind River VxWorks 6.5, 6.6, 6.7, 6.8, 6.9.3 and 6.9.4 has a Memory Leak in the IGMPv3 client component. There is an IPNET security vulnerability: IGMP Information leak via IGMPv3 specific membership report.

Action-Not Available
Vendor-windriverbeldenn/aNetApp, Inc.Siemens AGSonicWall Inc.
Product-power_meter_9810_firmwarehirschmann_rsp20ruggedcom_win7025_firmwarehirschmann_ees25sonicoshirschmann_grs1030hirschmann_grs1142ruggedcom_win7018_firmwarehirschmann_rspe32hirschmann_grs1130garrettcom_magnum_dx940ehirschmann_rspe35hirschmann_eesx20hirschmann_rspe37ruggedcom_win7018power_meter_9410_firmwarehirschmann_grs1042siprotec_5_firmwareruggedcom_win7000ruggedcom_win7200hirschmann_rsp35garrettcom_magnum_dx940e_firmwaree-series_santricity_os_controllervxworkshirschmann_msp40hirschmann_octopus_os3hirschmann_rsp30hirschmann_dragon_mach4000hirschmann_dragon_mach4500hirschmann_msp32hirschmann_rsp25hirschmann_rail_switch_power_smarthirschmann_eesx30hirschmann_grs1020hirschmann_rail_switch_power_litehirschmann_eagle20hirschmann_eagle30hirschmann_hiosruggedcom_win7025hirschmann_rspe30hirschmann_eagle_oneruggedcom_win7200_firmwaresiprotec_5hirschmann_ees20hirschmann_red25power_meter_9410power_meter_9810ruggedcom_win7000_firmwarehirschmann_msp30hirschmann_grs1120n/a
CWE ID-CWE-401
Missing Release of Memory after Effective Lifetime
CVE-2019-10920
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.81% / 73.80%
||
7 Day CHG~0.00%
Published-14 May, 2019 | 19:54
Updated-04 Aug, 2024 | 22:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Project data stored on the device, which is accessible via port 10005/tcp, can be decrypted due to a hardcoded encryption key. The security vulnerability could be exploited by an unauthenticated attacker with network access to port 10005/tcp. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-logo\!8_bm_firmwarelogo\!8_bmLOGO! 8 BM (incl. SIPLUS variants)
CWE ID-CWE-321
Use of Hard-coded Cryptographic Key
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2024-41792
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.2||CRITICAL
EPSS-0.55% / 67.45%
||
7 Day CHG~0.00%
Published-08 Apr, 2025 | 08:22
Updated-23 Sep, 2025 | 16:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). The web interface of affected devices contains a path traversal vulnerability. This could allow an unauthenticated attacker it to access arbitrary files on the device with root privileges.

Action-Not Available
Vendor-Siemens AG
Product-7kt_pac1260_data_manager7kt_pac1260_data_manager_firmwareSENTRON 7KT PAC1260 Data Manager
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2019-10941
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-5.3||MEDIUM
EPSS-0.18% / 40.01%
||
7 Day CHG~0.00%
Published-14 Sep, 2021 | 10:47
Updated-04 Aug, 2024 | 22:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEMA Server (All versions < V14 SP3). Missing authentication for functionality that requires administrative user identity could allow an attacker to obtain encoded system configuration backup files. This is only possible through network access to the affected system, and successful exploitation requires no system privileges.

Action-Not Available
Vendor-Siemens AG
Product-sinema_serverSINEMA Server
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2022-46355
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.40% / 60.11%
||
7 Day CHG~0.00%
Published-13 Dec, 2022 | 00:00
Updated-22 Apr, 2025 | 15:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SCALANCE X204RNA (HSR) (All versions < V3.2.7), SCALANCE X204RNA (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (HSR) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP/HSR) (All versions < V3.2.7). The affected products are vulnerable to an "Exposure of Sensitive Information to an Unauthorized Actor" vulnerability by leaking sensitive data in the HTTP Referer.

Action-Not Available
Vendor-Siemens AG
Product-6gk5204-0ba00-2mb26gk5204-0ba00-2kb26gk5204-0bs00-3pa36gk5204-0bs00-3pa3_firmware6gk5204-0ba00-2kb2_firmware6gk5204-0bs00-2na3_firmware6gk5204-0bs00-3la36gk5204-0bs00-3la3_firmware6gk5204-0bs00-2na36gk5204-0ba00-2mb2_firmwareSCALANCE X204RNA (HSR)SCALANCE X204RNA EEC (PRP/HSR)SCALANCE X204RNA EEC (HSR)SCALANCE X204RNA EEC (PRP)SCALANCE X204RNA (PRP)
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2024-39873
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.45% / 63.03%
||
7 Day CHG~0.00%
Published-09 Jul, 2024 | 12:05
Updated-27 Aug, 2025 | 20:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). The affected application does not properly implement brute force protection against user credentials in its web API. This could allow an attacker to learn user credentials that are vulnerable to brute force attacks.

Action-Not Available
Vendor-Siemens AG
Product-sinema_remote_connect_serverSINEMA Remote Connect Serversinema_remote_connect_server
CWE ID-CWE-307
Improper Restriction of Excessive Authentication Attempts
CVE-2003-0190
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-5||MEDIUM
EPSS-17.16% / 94.84%
||
7 Day CHG~0.00%
Published-02 May, 2003 | 00:00
Updated-03 Apr, 2025 | 01:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

OpenSSH-portable (OpenSSH) 3.6.1p1 and earlier with PAM support enabled immediately sends an error message when a user does not exist, which allows remote attackers to determine valid usernames via a timing attack.

Action-Not Available
Vendor-openpkgn/aOpenBSDSiemens AG
Product-scalance_x204rna_firmwarescalance_x204rnaopensshscalance_x204rna_eccscalance_x204rna_ecc_firmwareopenpkgn/a
CWE ID-CWE-203
Observable Discrepancy
CVE-2022-42733
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.32% / 54.83%
||
7 Day CHG~0.00%
Published-17 Nov, 2022 | 00:00
Updated-29 Apr, 2025 | 20:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in syngo Dynamics (All versions < VA40G HF01). syngo Dynamics application server hosts a web service using an operation with improper read access control that could allow files to be retrieved from any folder accessible to the account assigned to the website’s application pool.

Action-Not Available
Vendor-Siemens AG
Product-syngo_dynamics_cardiovascular_imaging_and_information_systemsyngo Dynamics
CWE ID-CWE-73
External Control of File Name or Path
CWE ID-CWE-610
Externally Controlled Reference to a Resource in Another Sphere
CVE-2022-42732
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.32% / 54.83%
||
7 Day CHG~0.00%
Published-17 Nov, 2022 | 00:00
Updated-29 Apr, 2025 | 21:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in syngo Dynamics (All versions < VA40G HF01). syngo Dynamics application server hosts a web service using an operation with improper read access control that could allow files to be retrieved from any folder accessible to the account assigned to the website’s application pool.

Action-Not Available
Vendor-Siemens AG
Product-syngo_dynamics_cardiovascular_imaging_and_information_systemsyngo Dynamics
CWE ID-CWE-73
External Control of File Name or Path
CWE ID-CWE-610
Externally Controlled Reference to a Resource in Another Sphere
CVE-2022-42894
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.32% / 54.30%
||
7 Day CHG~0.00%
Published-17 Nov, 2022 | 00:00
Updated-30 Apr, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in syngo Dynamics (All versions < VA40G HF01). An unauthenticated Server-Side Request Forgery (SSRF) vulnerability was identified in one of the web services exposed on the syngo Dynamics application that could allow for the leaking of NTLM credentials as well as local service enumeration.

Action-Not Available
Vendor-Siemens AG
Product-syngo_dynamics_cardiovascular_imaging_and_information_systemsyngo Dynamics
CWE ID-CWE-918
Server-Side Request Forgery (SSRF)
CVE-2024-54015
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.15% / 35.47%
||
7 Day CHG~0.00%
Published-11 Feb, 2025 | 10:28
Updated-12 Aug, 2025 | 12:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.90), SIPROTEC 5 6MD85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD89 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD89 (CP300) V9.6x (All versions < V9.68), SIPROTEC 5 6MU85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7KE85 (CP300) (All versions >= V8.80 < V10.0), SIPROTEC 5 7SA82 (CP150) (All versions < V9.90), SIPROTEC 5 7SA86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SA87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.90), SIPROTEC 5 7SD86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SD87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SJ86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SK82 (CP150) (All versions < V9.90), SIPROTEC 5 7SK85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.90), SIPROTEC 5 7SL86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SL87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SS85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7ST85 (CP300) (All versions >= V8.80 < V10.0), SIPROTEC 5 7ST85 (CP300) V9.6x (All versions < V9.68), SIPROTEC 5 7ST86 (CP300) (All versions < V10.0), SIPROTEC 5 7ST86 (CP300) V9.8x (All versions < V9.83), SIPROTEC 5 7SX82 (CP150) (All versions < V9.90), SIPROTEC 5 7SX85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SY82 (CP150) (All versions < V9.90), SIPROTEC 5 7UM85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.90), SIPROTEC 5 7UT85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VE85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VK87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VU85 (CP300) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.8 (All versions < V9.83), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.8 (All versions < V9.83), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions >= V8.80 < V9.90), SIPROTEC 5 Communication Module ETH-BD-2FO V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BD-2FO V9.8 (All versions < V9.83), SIPROTEC 5 Compact 7SX800 (CP050) (All versions >= V9.50 < V9.90). Affected devices do not properly validate SNMP GET requests. This could allow an unauthenticated, remote attacker to retrieve sensitive information of the affected devices with SNMPv2 GET requests using default credentials.

Action-Not Available
Vendor-Siemens AG
Product-SIPROTEC 5 7SA82 (CP150)SIPROTEC 5 7SL86 (CP300)SIPROTEC 5 7UM85 (CP300)SIPROTEC 5 7SS85 (CP300)SIPROTEC 5 7UT87 (CP300)SIPROTEC 5 7SY82 (CP150)SIPROTEC 5 7SJ82 (CP150)SIPROTEC 5 7VK87 (CP300)SIPROTEC 5 7ST86 (CP300)SIPROTEC 5 Compact 7SX800 (CP050)SIPROTEC 5 Communication Module ETH-BD-2FO V9.8SIPROTEC 5 6MD85 (CP300)SIPROTEC 5 7SD87 (CP300)SIPROTEC 5 7ST85 (CP300) V9.6xSIPROTEC 5 7SK85 (CP300)SIPROTEC 5 Communication Module ETH-BD-2FO V9.6SIPROTEC 5 7ST86 (CP300) V9.8xSIPROTEC 5 7UT86 (CP300)SIPROTEC 5 6MD86 (CP300)SIPROTEC 5 7KE85 (CP300)SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2)SIPROTEC 5 7SJ85 (CP300)SIPROTEC 5 6MU85 (CP300)SIPROTEC 5 7SD82 (CP150)SIPROTEC 5 7SD86 (CP300)SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.8SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.8SIPROTEC 5 7SX82 (CP150)SIPROTEC 5 7VE85 (CP300)SIPROTEC 5 7UT82 (CP150)SIPROTEC 5 7SJ81 (CP150)SIPROTEC 5 6MD89 (CP300)SIPROTEC 5 7SL87 (CP300)SIPROTEC 5 7SJ86 (CP300)SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.6SIPROTEC 5 7SA86 (CP300)SIPROTEC 5 7SX85 (CP300)SIPROTEC 5 Communication Module ETH-BD-2FOSIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2)SIPROTEC 5 6MD89 (CP300) V9.6xSIPROTEC 5 7SA87 (CP300)SIPROTEC 5 7SL82 (CP150)SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.6SIPROTEC 5 6MD84 (CP300)SIPROTEC 5 7SK82 (CP150)SIPROTEC 5 7UT85 (CP300)SIPROTEC 5 7ST85 (CP300)SIPROTEC 5 7VU85 (CP300)
CWE ID-CWE-1392
Use of Default Credentials
CVE-2024-39888
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.25% / 48.33%
||
7 Day CHG~0.00%
Published-09 Jul, 2024 | 12:05
Updated-27 Aug, 2025 | 20:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Mendix Encryption (All versions >= V10.0.0 < V10.0.2). Affected versions of the module define a specific hard-coded default value for the EncryptionKey constant, which is used in projects where no individual EncryptionKey was specified. This could allow to an attacker to decrypt any encrypted project data, as the default encryption key can be considered compromised.

Action-Not Available
Vendor-Siemens AG
Product-Mendix Encryptionmendix_encryption
CWE ID-CWE-547
Use of Hard-coded, Security-relevant Constants
CVE-2015-1358
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-5||MEDIUM
EPSS-0.80% / 73.55%
||
7 Day CHG~0.00%
Published-18 Feb, 2015 | 02:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The remote-management module in the (1) Multi Panels, (2) Comfort Panels, and (3) RT Advanced functionality in Siemens SIMATIC WinCC (TIA Portal) before 13 SP1 and in the (4) panels and (5) runtime functionality in SIMATIC WinCC flexible before 2008 SP3 Up7 does not properly encrypt credentials in transit, which makes it easier for remote attackers to determine cleartext credentials by sniffing the network and conducting a decryption attack.

Action-Not Available
Vendor-n/aSiemens AG
Product-winccn/a
CVE-2020-8169
Matching Score-8
Assigner-HackerOne
ShareView Details
Matching Score-8
Assigner-HackerOne
CVSS Score-7.5||HIGH
EPSS-0.06% / 17.79%
||
7 Day CHG+0.01%
Published-14 Dec, 2020 | 19:41
Updated-04 Aug, 2024 | 09:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

curl 7.62.0 through 7.70.0 is vulnerable to an information disclosure vulnerability that can lead to a partial password being leaked over the network and to the DNS server(s).

Action-Not Available
Vendor-n/aDebian GNU/LinuxSplunk LLC (Cisco Systems, Inc.)CURLSiemens AG
Product-sinec_infrastructure_network_servicessimatic_tim_1531_irc_firmwaredebian_linuxcurlsimatic_tim_1531_ircuniversal_forwarderhttps://github.com/curl/curl
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2020-8231
Matching Score-8
Assigner-HackerOne
ShareView Details
Matching Score-8
Assigner-HackerOne
CVSS Score-7.5||HIGH
EPSS-0.22% / 44.53%
||
7 Day CHG~0.00%
Published-14 Dec, 2020 | 19:39
Updated-04 Aug, 2024 | 09:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Due to use of a dangling pointer, libcurl 7.29.0 through 7.71.1 can use the wrong connection when sending data.

Action-Not Available
Vendor-n/aDebian GNU/LinuxOracle CorporationSplunk LLC (Cisco Systems, Inc.)CURLSiemens AG
Product-sinec_infrastructure_network_serviceslibcurldebian_linuxuniversal_forwardercommunications_cloud_native_core_policyhttps://github.com/curl/curl
CWE ID-CWE-416
Use After Free
CVE-2024-35210
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-5.1||MEDIUM
EPSS-0.18% / 39.72%
||
7 Day CHG~0.00%
Published-11 Jun, 2024 | 11:15
Updated-11 Feb, 2025 | 11:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V1.2). The affected web server is not enforcing HSTS. This could allow an attacker to perform downgrade attacks exposing confidential information.

Action-Not Available
Vendor-Siemens AG
Product-sinec_traffic_analyzerSINEC Traffic Analyzersinec_traffic_analyzer
CWE ID-CWE-319
Cleartext Transmission of Sensitive Information
CVE-2020-28397
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-5.3||MEDIUM
EPSS-0.18% / 39.87%
||
7 Day CHG~0.00%
Published-10 Aug, 2021 | 10:35
Updated-04 Aug, 2024 | 16:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7 PLCSIM Advanced (All versions > V2 < V4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (Version V4.4), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions > V2.5 < V2.9.2), SIMATIC S7-1500 Software Controller (All versions > V2.5 < V21.9), TIM 1531 IRC (incl. SIPLUS NET variants) (Version V2.1). Due to an incorrect authorization check in the affected component, an attacker could extract information about access protected PLC program variables over port 102/tcp from an affected device when reading multiple attributes at once.

Action-Not Available
Vendor-Siemens AG
Product-cpu_1517t-3_pn\/dpsiplus_cpu_1511f-1_pnsimatic_s7_plcsim_advancedcpu_1513pro_f-2_pn_firmwarecpu_1512sp-1_pncpu_1513r-1_pn_firmwarecpu_1516pro_f-2_pn_firmwarecpu_1515tf-2_pncpu_1212fccpu_1215c_firmwaresiplus_cpu_1511f-1_pn_firmwaresiplus_cpu_1510sp_f-1pn_firmwarecpu_1511tf-1pncpu_1212fc_firmwarecpu_1515sp_pc2_tf_firmwarecpu_1513f-1_pncpu_1517f-3_pn\/dp_firmwarecpu_1515f-2_firmwaretim_1531_irccpu_1515-2cpu_1507d_tf_firmwarecpu_1515sp_pc2_tfcpu_1211ccpu_1517f-3_pn\/dpsiplus_cpu-1516f-3_pn\/dpcpu_1217ccpu_1513f-1_pn_firmwarecpu_1516tf-3_pn\/dpcpu_1215fccpu_1510sp-1pn_firmwarecpu_1214fc_firmwarecpu_1517tf-3_pn\/dp_firmwarecpu_1516t-3_pn\/dp_firmwarecpu_1215ccpu_1518f-4_pn\/dp_firmwaresiplus_cpu_1512sp-1_pn_firmwarecpu_1517-3_pn\/dpsiplus_cpu_1518f-4_pn\/dp_firmwarecpu_1511f-1pncpu_1516f-3_firmwarecpu_1516pro-2_pn_firmwarecpu_1504d_tf_firmwaresiplus_cpu_1516-3_pn\/dp_firmwaresiplus_cpu_1513-1_pncpu_1518f-4_pn\/dpcpu_1516t-3_pn\/dpsiplus_cpu_1513-1_pn_firmwarecpu_1510sp-1pncpu_1217c_firmwarecpu_1211c_firmwarecpu_1513-1_pncpu_1512sp_f-1_pnsimatic_s7-1500_software_controllercpu_1518-4_pn\/dpsiplus_cpu_1518-4_pn\/dpcpu_1512sp_f-1_pn_firmwarecpu_1513pro_f-2_pnsiplus_cpu_1510sp_f-1pncpu_1214c_firmwaresiplus_cpu_1512sp_f-1pnsiplus_cpu_1513f-1_pncpu_1511t-1pncpu_1511f-1pn_firmwarecpu_1515r-2_pn_firmwarecpu_1512sp-1_pn_firmwarecpu_1515f-2cpu_1214ccpu_1517t-3_pn\/dp_firmwaresiplus_cpu_1512sp-1_pncpu_1517-3_pn\/dp_firmwaresiplus_cpu_1513f-1_pn_firmwarecpu_1516pro-2_pncpu_1516tf-3_pn\/dp_firmwaresiplus_cpu_1516-3_pn\/dpcpu_1513-1_pn_firmwarecpu_1515tf-2_pn_firmwaretim_1531_irc_firmwaresiplus_cpu_1518f-4_pn\/dpcpu_1512c-1_pncpu_1507d_tfcpu_1511t-1pn_firmwarecpu1510sp_f-1_firmwarecpu_1515r-2_pncpu_1214fccpu_1516f-3cpu_1511c-1_pn_firmwarecpu_1513r-1_pncpu_1516-3simatic_s7_plcsim_advanced_firmwarecpu_1515-2_firmwarecpu_1215fc_firmwarecpu_1511-1pn_firmwarecpu_1511c-1_pnsiplus_cpu_1511-1_pn_firmwarecpu1510sp_f-1cpu_1516pro_f-2_pnsiplus_cpu_1518-4_pn\/dp_firmwarecpu_1504d_tfcpu_1517tf-3_pn\/dpcpu_1511-1pncpu_1212ccpu_1515t-2_pnsiplus_cpu-1516f-3_pn\/dp_firmwarecpu_1512c-1_pn_firmwaresiplus_cpu_1511-1_pnsiplus_cpu_1512sp_f-1pn_firmwarecpu_1515t-2_pn_firmwarecpu_1212c_firmwarecpu_1518-4_pn\/dp_firmwarecpu_1511tf-1pn_firmwarecpu_1516-3_firmwareTIM 1531 IRC (incl. SIPLUS NET variants)SIMATIC S7-1500 Software ControllerSIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)SIMATIC Drive Controller familySIMATIC S7-1200 CPU family (incl. SIPLUS variants)SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)SIMATIC S7 PLCSIM Advanced
CWE ID-CWE-863
Incorrect Authorization
CVE-2015-1357
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-5||MEDIUM
EPSS-0.26% / 49.33%
||
7 Day CHG~0.00%
Published-02 Feb, 2015 | 15:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Siemens Ruggedcom WIN51xx devices with firmware before SS4.4.4624.35, WIN52xx devices with firmware before SS4.4.4624.35, WIN70xx devices with firmware before BS4.4.4621.32, and WIN72xx devices with firmware before BS4.4.4621.32 allow context-dependent attackers to discover password hashes by reading (1) files or (2) security logs.

Action-Not Available
Vendor-n/aSiemens AG
Product-ruggedcom_win5200ruggedcom_win5100ruggedcom_win7200ruggedcom_win7000ruggedcom_firmwaren/a
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2018-7083
Matching Score-8
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-8
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-7.5||HIGH
EPSS-0.54% / 66.95%
||
7 Day CHG~0.00%
Published-10 May, 2019 | 16:43
Updated-05 Aug, 2024 | 06:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

If a process running within Aruba Instant crashes, it may leave behind a "core dump", which contains the memory contents of the process at the time it crashed. It was discovered that core dumps are stored in a way that unauthenticated users can access them through the Aruba Instant web interface. Core dumps could contain sensitive information such as keys and passwords. Workaround: Block access to the Aruba Instant web interface from all untrusted users. Resolution: Fixed in Aruba Instant 4.2.4.12, 6.5.4.11, 8.3.0.6, and 8.4.0.0

Action-Not Available
Vendor-n/aSiemens AGAruba Networks
Product-aruba_instantscalance_w1750d_firmwarescalance_w1750dAruba Instant (IAP)
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2024-50310
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.41% / 60.97%
||
7 Day CHG~0.00%
Published-12 Nov, 2024 | 12:49
Updated-13 Nov, 2024 | 23:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC CP 1543-1 V4.0 (6GK7543-1AX10-0XE0) (All versions >= V4.0.44 < V4.0.50). Affected devices do not properly handle authorization. This could allow an unauthenticated remote attacker to gain access to the filesystem.

Action-Not Available
Vendor-Siemens AG
Product-simatic_cp_1543-1simatic_cp_1543-1_firmwareSIMATIC CP 1543-1 V4.0simatic_cp_1543-1
CWE ID-CWE-863
Incorrect Authorization
CVE-2018-21247
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-1.48% / 80.64%
||
7 Day CHG~0.00%
Published-17 Jun, 2020 | 15:10
Updated-05 Aug, 2024 | 12:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in LibVNCServer before 0.9.13. There is an information leak (of uninitialized memory contents) in the libvncclient/rfbproto.c ConnectToRFBRepeater function.

Action-Not Available
Vendor-libvnc_projectn/aDebian GNU/LinuxSiemens AGCanonical Ltd.openSUSE
Product-ubuntu_linuxsimatic_itc1500_prosimatic_itc1900simatic_itc2200_pro_firmwaresimatic_itc2200simatic_itc1500_pro_firmwaredebian_linuxsimatic_itc1500simatic_itc1900_firmwaresimatic_itc1900_pro_firmwaresimatic_itc1500_firmwaresimatic_itc2200_firmwaresimatic_itc2200_prolibvncserversimatic_itc1900_proleapn/a
CWE ID-CWE-909
Missing Initialization of Resource
CVE-2023-25957
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.1||CRITICAL
EPSS-0.05% / 16.08%
||
7 Day CHG~0.00%
Published-14 Mar, 2023 | 09:31
Updated-27 Feb, 2025 | 15:01
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Mendix SAML (Mendix 7 compatible) (All versions >= V1.16.4 < V1.17.3), Mendix SAML (Mendix 8 compatible) (All versions >= V2.2.0 < V2.3.0), Mendix SAML (Mendix 9 latest compatible, New Track) (All versions >= V3.1.9 < V3.3.1), Mendix SAML (Mendix 9 latest compatible, Upgrade Track) (All versions >= V3.1.8 < V3.3.0), Mendix SAML (Mendix 9.6 compatible, New Track) (All versions >= V3.1.9 < V3.2.7), Mendix SAML (Mendix 9.6 compatible, Upgrade Track) (All versions >= V3.1.8 < V3.2.6). The affected versions of the module insufficiently verify the SAML assertions. This could allow unauthenticated remote attackers to bypass authentication and get access to the application. For compatibility reasons, fix versions still contain this issue, but only when the recommended, default configuration option `'Use Encryption'` is disabled.

Action-Not Available
Vendor-mendixSiemens AG
Product-samlMendix SAML (Mendix 9 latest compatible, New Track)Mendix SAML (Mendix 8 compatible)Mendix SAML (Mendix 9 latest compatible, Upgrade Track)Mendix SAML (Mendix 9.6 compatible, New Track)Mendix SAML (Mendix 9.6 compatible, Upgrade Track)Mendix SAML (Mendix 7 compatible)
CWE ID-CWE-303
Incorrect Implementation of Authentication Algorithm
CWE ID-CWE-287
Improper Authentication
CVE-2022-34659
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.34% / 56.27%
||
7 Day CHG~0.00%
Published-10 Aug, 2022 | 11:17
Updated-03 Aug, 2024 | 09:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Simcenter STAR-CCM+ (All versions only if the Power-on-Demand public license server is used). Affected applications expose user, host and display name of users, when the public license server is used. This could allow an attacker to retrieve this information.

Action-Not Available
Vendor-Siemens AG
Product-simcenter_star-ccm\+_viewerSimcenter STAR-CCM+
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2019-8277
Matching Score-8
Assigner-Kaspersky
ShareView Details
Matching Score-8
Assigner-Kaspersky
CVSS Score-7.5||HIGH
EPSS-0.82% / 73.98%
||
7 Day CHG~0.00%
Published-09 Mar, 2019 | 00:00
Updated-04 Aug, 2024 | 21:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

UltraVNC revision 1211 contains multiple memory leaks (CWE-665) in VNC server code, which allows an attacker to read stack memory and can be abused for information disclosure. Combined with another vulnerability, it can be used to leak stack memory and bypass ASLR. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1212.

Action-Not Available
Vendor-uvncSiemens AGKaspersky Lab
Product-sinumerik_pcu_base_win10_software\/ipcultravncsinumerik_pcu_base_win7_software\/ipcsinumerik_access_mymachine\/p2pUltraVNC
CWE ID-CWE-665
Improper Initialization
CVE-2014-8552
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-5||MEDIUM
EPSS-0.12% / 30.83%
||
7 Day CHG~0.00%
Published-26 Nov, 2014 | 11:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to read arbitrary files via crafted packets.

Action-Not Available
Vendor-n/aSiemens AG
Product-simatic_pcs7simatic_pcs_7simatic_tiaportalsimatic_winccn/a
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2022-32254
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-4.3||MEDIUM
EPSS-0.29% / 52.09%
||
7 Day CHG~0.00%
Published-14 Jun, 2022 | 09:22
Updated-03 Aug, 2024 | 07:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). A customized HTTP POST request could force the application to write the status of a given user to a log file, exposing sensitive user information that could provide valuable guidance to an attacker.

Action-Not Available
Vendor-Siemens AG
Product-sinema_remote_connect_serverSINEMA Remote Connect Server
CWE ID-CWE-532
Insertion of Sensitive Information into Log File
CVE-2022-32258
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-5.3||MEDIUM
EPSS-0.26% / 49.40%
||
7 Day CHG~0.00%
Published-14 Jun, 2022 | 09:22
Updated-03 Aug, 2024 | 07:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). The affected application contains an older feature that allows to import device configurations via a specific endpoint. An attacker could use this vulnerability for information disclosure.

Action-Not Available
Vendor-Siemens AG
Product-sinema_remote_connect_serverSINEMA Remote Connect Serversinema_remote_connect_server
CWE ID-CWE-448
Obsolete Feature in UI
CVE-2022-32255
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-5.3||MEDIUM
EPSS-0.24% / 47.14%
||
7 Day CHG~0.00%
Published-14 Jun, 2022 | 09:22
Updated-03 Aug, 2024 | 07:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). The affected application consists of a web service that lacks proper access control for some of the endpoints. This could lead to unauthorized access to limited information.

Action-Not Available
Vendor-Siemens AG
Product-sinema_remote_connect_serverSINEMA Remote Connect Serversinema_remote_connect_server
CWE ID-CWE-284
Improper Access Control
CVE-2014-2732
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-5||MEDIUM
EPSS-0.35% / 56.99%
||
7 Day CHG~0.00%
Published-19 Apr, 2014 | 19:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Multiple directory traversal vulnerabilities in the integrated web server in Siemens SINEMA Server before 12 SP1 allow remote attackers to access arbitrary files via HTTP traffic to port (1) 4999 or (2) 80.

Action-Not Available
Vendor-n/aSiemens AG
Product-sinema_servern/a
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2022-29801
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.41% / 60.54%
||
7 Day CHG~0.00%
Published-10 May, 2022 | 09:47
Updated-03 Aug, 2024 | 06:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Teamcenter V12.4 (All versions < V12.4.0.13), Teamcenter V13.0 (All versions < V13.0.0.9). The application contains a XML External Entity Injection (XXE) vulnerability. This could allow an attacker to view files on the application server filesystem.

Action-Not Available
Vendor-Siemens AG
Product-teamcenterTeamcenter V12.4Teamcenter V13.0
CWE ID-CWE-611
Improper Restriction of XML External Entity Reference
CVE-2020-25230
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.10% / 27.88%
||
7 Day CHG~0.00%
Published-14 Dec, 2020 | 21:05
Updated-04 Aug, 2024 | 15:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Due to the usage of an outdated cipher mode on port 10005/tcp, an attacker could extract the encryption key from a captured communication with the device.

Action-Not Available
Vendor-Siemens AG
Product-logo\!_8_bmlogo\!_8_bm_firmwareLOGO! 8 BM (incl. SIPLUS variants)
CWE ID-CWE-327
Use of a Broken or Risky Cryptographic Algorithm
CVE-2014-0160
Matching Score-8
Assigner-Red Hat, Inc.
ShareView Details
Matching Score-8
Assigner-Red Hat, Inc.
CVSS Score-7.5||HIGH
EPSS-94.46% / 99.99%
||
7 Day CHG~0.00%
Published-07 Apr, 2014 | 00:00
Updated-22 Oct, 2025 | 01:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Known KEV||Action Due Date - 2022-05-25||Apply updates per vendor instructions.

The (1) TLS and (2) DTLS implementations in OpenSSL 1.0.1 before 1.0.1g do not properly handle Heartbeat Extension packets, which allows remote attackers to obtain sensitive information from process memory via crafted packets that trigger a buffer over-read, as demonstrated by reading private keys, related to d1_both.c and t1_lib.c, aka the Heartbleed bug.

Action-Not Available
Vendor-riconintellianfilezilla-projectn/aRed Hat, Inc.Siemens AGopenSUSECanonical Ltd.Splunk LLC (Cisco Systems, Inc.)OpenSSLMitel Networks Corp.Fedora ProjectBroadcom Inc.Debian GNU/Linux
Product-filezilla_serverenterprise_linux_serversymantec_messaging_gatewaywincc_open_architectureubuntu_linuxelan-8.2enterprise_linux_desktopv100simatic_s7-1500_firmwaresimatic_s7-1500tapplication_processing_engine_firmwarevirtualizationdebian_linuxsimatic_s7-1500enterprise_linux_server_eusmivoicecp_1543-1_firmwarestorages9922lmicollabv100_firmwaregluster_storagev60_firmwareapplication_processing_engineopensusev60enterprise_linux_workstationsimatic_s7-1500t_firmwareenterprise_linux_server_ausenterprise_linux_server_tusopensslfedoras9922l_firmwaresplunkcp_1543-1n/aOpenSSL
CWE ID-CWE-125
Out-of-bounds Read
CVE-2020-25232
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.19% / 40.36%
||
7 Day CHG~0.00%
Published-14 Dec, 2020 | 21:05
Updated-04 Aug, 2024 | 15:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Due to the usage of an insecure random number generation function and a deprecated cryptographic function, an attacker could extract the key that is used when communicating with an affected device on port 8080/tcp.

Action-Not Available
Vendor-Siemens AG
Product-logo\!_8_bmlogo\!_8_bm_firmwareLOGO! 8 BM (incl. SIPLUS variants)
CWE ID-CWE-327
Use of a Broken or Risky Cryptographic Algorithm
CVE-2022-29874
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.35% / 56.66%
||
7 Day CHG~0.00%
Published-10 May, 2022 | 09:47
Updated-09 Dec, 2025 | 16:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SICAM T (All versions < V3.0). Affected devices do not encrypt web traffic with clients but communicate in cleartext via HTTP. This could allow an unauthenticated attacker to capture the traffic and interfere with the functionality of the device.

Action-Not Available
Vendor-Siemens AG
Product-7kg8551-0aa12-0aa0_firmware7kg8550-0aa10-2aa07kg8501-0aa31-2aa07kg8500-0aa30-2aa07kg8551-0aa32-2aa07kg8551-0aa01-0aa0_firmware7kg8551-0aa12-2aa0_firmware7kg8550-0aa30-2aa07kg8501-0aa32-0aa07kg8551-0aa02-0aa07kg8501-0aa31-0aa07kg8501-0aa12-0aa0_firmware7kg8500-0aa30-0aa0_firmware7kg8501-0aa01-2aa0_firmware7kg8551-0aa12-0aa07kg8501-0aa02-0aa0_firmware7kg8551-0aa31-2aa0_firmware7kg8551-0aa32-0aa07kg8551-0aa02-2aa0_firmware7kg8501-0aa11-0aa07kg8551-0aa01-2aa07kg8500-0aa00-2aa07kg8551-0aa31-0aa0_firmware7kg8501-0aa01-0aa0_firmware7kg8551-0aa11-2aa0_firmware7kg8500-0aa30-0aa07kg8501-0aa11-0aa0_firmware7kg8500-0aa10-0aa07kg8550-0aa00-0aa07kg8500-0aa00-2aa0_firmware7kg8501-0aa32-2aa07kg8500-0aa00-0aa0_firmware7kg8501-0aa31-2aa0_firmware7kg8550-0aa30-2aa0_firmware7kg8551-0aa02-0aa0_firmware7kg8550-0aa00-2aa0_firmware7kg8501-0aa12-2aa07kg8551-0aa11-0aa07kg8501-0aa12-2aa0_firmware7kg8550-0aa30-0aa07kg8501-0aa11-2aa0_firmware7kg8501-0aa02-0aa07kg8551-0aa31-2aa07kg8551-0aa31-0aa07kg8500-0aa10-0aa0_firmware7kg8551-0aa12-2aa07kg8551-0aa11-2aa07kg8501-0aa11-2aa07kg8501-0aa32-2aa0_firmware7kg8500-0aa00-0aa07kg8551-0aa01-2aa0_firmware7kg8551-0aa32-2aa0_firmware7kg8550-0aa00-2aa07kg8550-0aa30-0aa0_firmware7kg8500-0aa30-2aa0_firmware7kg8551-0aa01-0aa07kg8550-0aa10-0aa07kg8500-0aa10-2aa07kg8501-0aa12-0aa07kg8550-0aa00-0aa0_firmware7kg8500-0aa10-2aa0_firmware7kg8501-0aa02-2aa07kg8551-0aa11-0aa0_firmware7kg8550-0aa10-0aa0_firmware7kg8551-0aa02-2aa07kg8551-0aa32-0aa0_firmware7kg8501-0aa01-2aa07kg8501-0aa02-2aa0_firmware7kg8501-0aa32-0aa0_firmware7kg8501-0aa31-0aa0_firmware7kg8501-0aa01-0aa07kg8550-0aa10-2aa0_firmwareSICAM T
CWE ID-CWE-319
Cleartext Transmission of Sensitive Information
CVE-2022-29881
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-6.9||MEDIUM
EPSS-1.09% / 77.59%
||
7 Day CHG~0.00%
Published-10 May, 2022 | 09:47
Updated-09 Dec, 2025 | 16:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SICAM T (All versions < V3.0). The web based management interface of affected devices does not employ special access protection for certain internal developer views. This could allow unauthenticated users to extract internal configuration details.

Action-Not Available
Vendor-Siemens AG
Product-7kg8551-0aa12-0aa0_firmware7kg8550-0aa10-2aa07kg8501-0aa31-2aa07kg8500-0aa30-2aa07kg8551-0aa32-2aa07kg8551-0aa01-0aa0_firmware7kg8551-0aa12-2aa0_firmware7kg8550-0aa30-2aa07kg8501-0aa32-0aa07kg8551-0aa02-0aa07kg8501-0aa31-0aa07kg8501-0aa12-0aa0_firmware7kg8500-0aa30-0aa0_firmware7kg8501-0aa01-2aa0_firmware7kg8551-0aa12-0aa07kg8501-0aa02-0aa0_firmware7kg8551-0aa31-2aa0_firmware7kg8551-0aa32-0aa07kg8551-0aa02-2aa0_firmware7kg8501-0aa11-0aa07kg8551-0aa01-2aa07kg8500-0aa00-2aa07kg8551-0aa31-0aa0_firmware7kg8501-0aa01-0aa0_firmware7kg8551-0aa11-2aa0_firmware7kg8500-0aa30-0aa07kg8501-0aa11-0aa0_firmware7kg8500-0aa10-0aa07kg8550-0aa00-0aa07kg8500-0aa00-2aa0_firmware7kg8501-0aa32-2aa07kg8500-0aa00-0aa0_firmware7kg8501-0aa31-2aa0_firmware7kg8550-0aa30-2aa0_firmware7kg8551-0aa02-0aa0_firmware7kg8550-0aa00-2aa0_firmware7kg8501-0aa12-2aa07kg8551-0aa11-0aa07kg8501-0aa12-2aa0_firmware7kg8550-0aa30-0aa07kg8501-0aa11-2aa0_firmware7kg8501-0aa02-0aa07kg8551-0aa31-2aa07kg8551-0aa31-0aa07kg8500-0aa10-0aa0_firmware7kg8551-0aa12-2aa07kg8551-0aa11-2aa07kg8501-0aa11-2aa07kg8501-0aa32-2aa0_firmware7kg8500-0aa00-0aa07kg8551-0aa01-2aa0_firmware7kg8551-0aa32-2aa0_firmware7kg8550-0aa00-2aa07kg8550-0aa30-0aa0_firmware7kg8500-0aa30-2aa0_firmware7kg8551-0aa01-0aa07kg8550-0aa10-0aa07kg8500-0aa10-2aa07kg8501-0aa12-0aa07kg8550-0aa00-0aa0_firmware7kg8500-0aa10-2aa0_firmware7kg8501-0aa02-2aa07kg8551-0aa11-0aa0_firmware7kg8550-0aa10-0aa0_firmware7kg8551-0aa02-2aa07kg8551-0aa32-0aa0_firmware7kg8501-0aa01-2aa07kg8501-0aa02-2aa0_firmware7kg8501-0aa32-0aa0_firmware7kg8501-0aa31-0aa0_firmware7kg8501-0aa01-0aa07kg8550-0aa10-2aa0_firmwareSICAM T
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2020-15784
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-5.3||MEDIUM
EPSS-0.11% / 29.59%
||
7 Day CHG~0.00%
Published-09 Sep, 2020 | 18:11
Updated-04 Aug, 2024 | 13:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Spectrum Power 4 (All versions < V4.70 SP8). Insecure storage of sensitive information in the configuration files could allow the retrieval of user names.

Action-Not Available
Vendor-Siemens AG
Product-spectrum_power_4Spectrum Power 4
CWE ID-CWE-312
Cleartext Storage of Sensitive Information
CVE-2020-10037
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.32% / 54.83%
||
7 Day CHG~0.00%
Published-14 Jul, 2020 | 13:18
Updated-04 Aug, 2024 | 10:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). By performing a flooding attack against the web server, an attacker might be able to gain read access to the device's memory, possibly revealing confidential information.

Action-Not Available
Vendor-Siemens AG
Product-sicam_t_firmwaresicam_mmusicam_sgu_firmwaresicam_mmu_firmwaresicam_sgusicam_tSICAM TSICAM MMUSICAM SGU
CWE ID-CWE-125
Out-of-bounds Read
CVE-2024-41904
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.59% / 68.77%
||
7 Day CHG~0.00%
Published-13 Aug, 2024 | 07:54
Updated-14 Aug, 2024 | 18:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V2.0). The affected application do not properly enforce restriction of excessive authentication attempts. This could allow an unauthenticated attacker to conduct brute force attacks against legitimate user credentials or keys.

Action-Not Available
Vendor-Siemens AG
Product-sinec_traffic_analyzerSINEC Traffic Analyzersinec_traffic_analyzer
CWE ID-CWE-307
Improper Restriction of Excessive Authentication Attempts
CVE-2022-27480
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.36% / 57.76%
||
7 Day CHG~0.00%
Published-12 Apr, 2022 | 09:08
Updated-03 Aug, 2024 | 05:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SICAM A8000 CP-8031 (All versions < V4.80), SICAM A8000 CP-8050 (All versions < V4.80). Affected devices do not require an user to be authenticated to access certain files. This could allow unauthenticated attackers to download these files.

Action-Not Available
Vendor-Siemens AG
Product-sicam_a8000_cp-8031sicam_a8000_cp-8050sicam_a8000_cp-8031_firmwaresicam_a8000_cp-8050_firmwareSICAM A8000 CP-8050SICAM A8000 CP-8031
CWE ID-CWE-862