Arbitrary code execution vulnerability on Micro Focus Operation Bridge Reporter, affecting version 10.40 and earlier. The vulnerability could allow remote attackers to execute arbitrary code on affected installations of OBR.
An issue was discovered on D-Link DIR-600M 3.02, 3.03, 3.04, and 3.06 devices. wan.htm can be accessed directly without authentication, which can lead to disclosure of information about the WAN, and can also be leveraged by an attacker to modify the data fields of the page.
A broken access control vulnerability found in Advan VD-1 firmware version 230 leads to insecure ADB service. An attacker can send a POST request to cgibin/AdbSetting.cgi to enable ADB without any authentication then take the compromised device as a relay or to install mining software.
Vulnerability in the Oracle Hospitality Simphony product of Oracle Food and Beverage Applications (component: Simphony Enterprise Server). Supported versions that are affected are 19.1.0-19.5.4. Easily exploitable vulnerability allows unauthenticated attacker with network access via HTTP to compromise Oracle Hospitality Simphony. Successful attacks of this vulnerability can result in takeover of Oracle Hospitality Simphony. CVSS 3.1 Base Score 9.8 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
Advantech WISE-PaaS/RMM, Versions 3.3.29 and prior. There is an unsecured function that allows anyone who can access the IP address to use the function without authentication.
An issue was discovered in Squid through 4.7. When handling requests from users, Squid checks its rules to see if the request should be denied. Squid by default comes with rules to block access to the Cache Manager, which serves detailed server information meant for the maintainer. This rule is implemented via url_regex. The handler for url_regex rules URL decodes an incoming request. This allows an attacker to encode their URL to bypass the url_regex check, and gain access to the blocked resource.
Due to unencrypted and unauthenticated data communication, the wireless barcode scanner Inateck BCST-60 is prone to keystroke injection attacks. Thus, an attacker is able to send arbitrary keystrokes to a victim's computer system, e.g., to install malware when the target system is unattended. In this way, an attacker can remotely take control over the victim's computer that is operated with an affected receiver of this device.
Windows Mobile Device Management Elevation of Privilege Vulnerability
Anviz access control devices allow remote attackers to issue commands without a password.
An issue was discovered in upgrade_firmware.cgi on VStarcam 100T (C7824WIP) CH-sys-48.53.75.119~123 and 200V (C38S) CH-sys-48.53.203.119~123 devices. A remote command can be executed through a system firmware update without authentication. The attacker can modify the files within the internal firmware or even steal account information by executing a command.
An issue was discovered in upgrade_htmls.cgi on VStarcam 100T (C7824WIP) KR75.8.53.20 and 200V (C38S) KR203.18.1.20 devices. The web service, network, and account files can be manipulated through a web UI firmware update without any authentication. The attacker can achieve access to the device through a manipulated web UI firmware update.
Improper Access Control in the RCP+ server of the Bosch Video Recording Manager (VRM) component allows arbitrary and unauthenticated access to a limited subset of certificates, stored in the underlying Microsoft Windows operating system. The fixed versions implement modified authentication checks. Prior releases of VRM software version 3.70 are considered unaffected. This vulnerability affects VRM v3.70.x, v3.71 < v3.71.0034 and v3.81 < 3.81.0050; DIVAR IP 5000 3.80 < 3.80.0039; BVMS all versions using VRM.
A Missing Authentication for Critical Function vulnerability in SUSE Manager allows anyone with access to the websocket at /rhn/websocket/minion/remote-commands to execute arbitrary commands as root. This issue affects Container suse/manager/5.0/x86_64/server:5.0.5.7.30.1: from ? before 0.3.7-150600.3.6.2; Container suse/manager/5.0/x86_64/server:5.0.5.7.30.1: from ? before 5.0.14-150600.4.17.1; Container suse/manager/5.0/x86_64/server:5.0.5.7.30.1: from ? before 5.0.14-150600.4.17.1; Image SLES15-SP4-Manager-Server-4-3-BYOS: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Server-4-3-BYOS: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Server-4-3-BYOS-Azure: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Server-4-3-BYOS-Azure: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Server-4-3-BYOS-EC2: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Server-4-3-BYOS-EC2: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Server-4-3-BYOS-GCE: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Server-4-3-BYOS-GCE: from ? before 4.3.33-150400.3.55.2; SUSE Manager Server Module 4.3: from ? before 0.3.7-150400.3.39.4; SUSE Manager Server Module 4.3: from ? before 4.3.33-150400.3.55.2; SUSE Manager Server Module 4.3: from ? before 4.3.33-150400.3.55.2.
SAP PowerDesigner - version 16.7, has improper access control which might allow an unauthenticated attacker to run arbitrary queries against the back-end database via Proxy.
The web management interface of Okcat Parking Management Platform from ZONG YU has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to directly access system functions. These functions include opening gates, viewing license plates and parking records, and restarting the system.
D-Link - CWE-288:Authentication Bypass Using an Alternate Path or Channel
Fujifilm FCR Capsula X/ Carbon X/ FCR XC-2, model versions CR-IR 357 FCR Carbon X, CR-IR 357 FCR XC-2, FCR-IR 357 FCR Capsula X provide insecure telnet services that lack authentication requirements. An attacker who successfully exploits this vulnerability may be able to access the underlying operating system.
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 and newer (All versions), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 and newer (All versions). An attacker with network access to affected installations, which are configured without "Encrypted Communication", can execute arbitrary code. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected installation. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.
Missing authentication checks in the query.fcgi endpoint of NS3000 v8.1.1.125110 , v7.2.8.124852 , and v7.x and NS2000 v7.02.08 allows attackers to execute a session hijacking attack.
MiR100, MiR200 and other MiR robots use the Robot Operating System (ROS) default packages exposing the computational graph without any sort of authentication. This allows attackers with access to the internal wireless and wired networks to take control of the robot seamlessly. In combination with CVE-2020-10269 and CVE-2020-10271, this flaw allows malicious actors to command the robot at desire.
A vulnerability has been identified in SINEC NMS (All versions < V4.0). The affected application exposes an endpoint that allows an unauthorized modification of administrative credentials. This could allow an unauthenticated attacker to reset the superadmin password and gain full control of the application (ZDI-CAN-26569).
The D-Link DIR-816 A2 1.11 router only checks the random token when authorizing a goform request. An attacker can get this token from dir_login.asp and use a hidden API URL /goform/SystemCommand to execute a system command without authentication.
CasaOS is an open-source Personal Cloud system. Due to a lack of IP address verification an unauthenticated attackers can execute arbitrary commands as `root` on CasaOS instances. The problem was addressed by improving the detection of client IP addresses in `391dd7f`. This patch is part of CasaOS 0.4.4. Users should upgrade to CasaOS 0.4.4. If they can't, they should temporarily restrict access to CasaOS to untrusted users, for instance by not exposing it publicly.
IBM Spectrum Protect Server 8.1 through 8.1.26 could allow attacker to bypass authentication due to improper session authentication which can result in access to unauthorized resources.
The Civi - Job Board & Freelance Marketplace WordPress Theme plugin for WordPress is vulnerable to authentication bypass in all versions up to, and including, 2.1.4. This is due to a lack of user validation before changing a password. This makes it possible for unauthenticated attackers to change the password of arbitrary users, including administrators, if the attacker knows the username of the victim.
A Missing Authentication for Critical Function issue was discovered in Schneider Electric InduSoft Web Studio v8.0 SP2 or prior, and InTouch Machine Edition v8.0 SP2 or prior. InduSoft Web Studio provides the capability for an HMI client to trigger script execution on the server for the purposes of performing customized calculations or actions. A remote malicious entity could bypass the server authentication and trigger the execution of an arbitrary command. The command is executed under high privileges and could lead to a complete compromise of the server.
Langflow versions prior to 1.3.0 are susceptible to code injection in the /api/v1/validate/code endpoint. A remote and unauthenticated attacker can send crafted HTTP requests to execute arbitrary code.
NetAlertX is a network, presence scanner and alert framework. Prior to version 25.4.14, it is possible to bypass the authentication mechanism of NetAlertX to update settings without authentication. An attacker can trigger sensitive functions within util.php by sending crafted requests to /index.php. This issue has been patched in version 25.4.14.
Zoho ManageEngine ADSelfService Plus through 6113 has an authentication bypass that can be exploited to steal the domain controller session token for identity spoofing, thereby achieving the privileges of the domain controller administrator. NOTE: the vendor's perspective is that they have "found no evidence or detail of a security vulnerability."
A potential security vulnerability has been identified in HPE Application Performance Management (BSM) Platform versions 9.26, 9.30, 9.40. The vulnerability could be remotely exploited to allow code execution.
Built-in SMS-configuration command in Forever KidsWatch Call Me KW50 R36_YDR_A3PW_GM7S_V1.0_2019_07_15_16.19.24_cob_h and Forever KidsWatch Call Me 2 KW-60 R36CW_YDE_S4_A29_2_V1.0_2023.05.24_22.49.44_cob_b allows malicious users to change the device IMEI-number which allows for forging the identity of the device.
STW (aka Sensor-Technik Wiedemann) TCG-4 Connectivity Module DeploymentPackage_v3.03r0-Impala and DeploymentPackage_v3.04r2-Jellyfish and TCG-4lite Connectivity Module DeploymentPackage_v3.04r2-Jellyfish allow an attacker to gain full remote access with root privileges without the need for authentication, giving an attacker arbitrary remote code execution over LTE / 4G network via SMS.
Vulnerability in the Oracle Scripting product of Oracle E-Business Suite (component: iSurvey Module). Supported versions that are affected are 12.2.3-12.2.14. Easily exploitable vulnerability allows unauthenticated attacker with network access via HTTP to compromise Oracle Scripting. Successful attacks of this vulnerability can result in takeover of Oracle Scripting. CVSS 3.1 Base Score 9.8 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
Swissphone DiCal-RED 4009 devices allow a remote attacker to gain a root shell via TELNET without authentication.
register_send.php on D-Link DIR-850L REV. B (with firmware through FW208WWb02) devices does not require authentication, which can result in unintended enrollment in mydlink Cloud Services.
Vasion Print (formerly PrinterLogic) before Virtual Appliance Host 22.0.933 Application 20.0.2368 allows Unauthenticated Driver Package Editing V-2024-008.
VMware Cloud Director Appliance contains an authentication bypass vulnerability in case VMware Cloud Director Appliance was upgraded to 10.5 from an older version. On an upgraded version of VMware Cloud Director Appliance 10.5, a malicious actor with network access to the appliance can bypass login restrictions when authenticating on port 22 (ssh) or port 5480 (appliance management console) . This bypass is not present on port 443 (VCD provider and tenant login). On a new installation of VMware Cloud Director Appliance 10.5, the bypass is not present. VMware Cloud Director Appliance is impacted since it uses an affected version of sssd from the underlying Photon OS. The sssd issue is no longer present in versions of Photon OS that ship with sssd-2.8.1-11 or higher (Photon OS 3) or sssd-2.8.2-9 or higher (Photon OS 4 and 5).
An issue in Planet Technologies WDRT-1800AX v1.01-CP21 allows attackers to bypass authentication and escalate privileges to root via manipulation of the LoginStatus cookie.
A Missing Authentication in Critical Function in Bosch IP cameras allows an unauthenticated remote attacker to extract sensitive information or change settings of the camera by sending crafted requests to the device. Only devices of the CPP6, CPP7 and CPP7.3 family with firmware 7.70, 7.72, and 7.80 prior to B128 are affected by this vulnerability. Versions 7.62 or lower and INTEOX cameras are not affected.
Vasion Print (formerly PrinterLogic) before Virtual Appliance Host 22.0.913 Application 20.0.2253 allows Addition of Partial Admin Users Without Authentication V-2024-002.
A CWE-306 "Missing Authentication for Critical Function" in maxprofile/menu/routes.lua in Q-Free MaxTime less than or equal to version 2.11.0 allows an unauthenticated remote attacker to edit user group permissions via crafted HTTP requests.
A CWE-306 "Missing Authentication for Critical Function" in maxprofile/menu/routes.lua in Q-Free MaxTime less than or equal to version 2.11.0 allows an unauthenticated remote attacker to edit user permissions via crafted HTTP requests.
A Missing Authentication for Critical Function vulnerability in the UniFi Connect EV Station Pro may allow a malicious actor with physical or adjacent access to perform an unauthorized factory reset. Affected Products: UniFi Connect EV Station Pro (Version 1.5.18 and earlier) Mitigation: Update UniFi Connect EV Station Pro to Version 1.5.27 or later
A CWE-306 "Missing Authentication for Critical Function" in maxtime/handleRoute.lua in Q-Free MaxTime less than or equal to version 2.11.0 allows an unauthenticated remote attacker to affect the device confidentiality, integrity, or availability in multiple unspecified ways via crafted HTTP requests.
The AdForest theme for WordPress is vulnerable to authentication bypass in all versions up to, and including, 5.1.8. This is due to the plugin not properly verifying a user's identity prior to logging them in as that user. This makes it possible for unauthenticated attackers to authenticate as any user as long as they have configured OTP login by phone number.
A CWE-306 "Missing Authentication for Critical Function" in maxprofile/guest-mode/routes.lua in Q-Free MaxTime less than or equal to version 2.11.0 allows an unauthenticated remote attacker to enable passwordless guest mode via crafted HTTP requests.
A CWE-306 "Missing Authentication for Critical Function" in maxprofile/accounts/routes.lua in Q-Free MaxTime less than or equal to version 2.11.0 allows an unauthenticated remote attacker to reset arbitrary user passwords via crafted HTTP requests.
A CWE-306 "Missing Authentication for Critical Function" in maxprofile/accounts/routes.lua in Q-Free MaxTime less than or equal to version 2.11.0 allows an unauthenticated remote attacker to create arbitrary users, including administrators, via crafted HTTP requests.
The administrative web interface of mySCADA myPRO Manager can be accessed without authentication which could allow an unauthorized attacker to retrieve sensitive information and upload files without the associated password.
An attacker could modify or disable settings, disrupt fuel monitoring and supply chain operations, leading to disabling of ATG monitoring. This would result in potential safety hazards in fuel storage and transportation.