A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker with network access to the SiPass integrated server to bypass the authentication mechanism and perform administrative operations.
A vulnerability has been identified in SINAMICS S200 (All versions with serial number beginning with SZVS8, SZVS9, SZVS0 or SZVSN and the FS number is 02). The affected device contains an unlocked bootloader. This security oversight enables attackers to inject malicious code, or install untrusted firmware. The intrinsic security features designed to protect against data manipulation and unauthorized access are compromised when the bootloader is not secured.
A vulnerability has been identified in Polarion ALM (All versions < V2404.0). The REST API endpoints of doorsconnector of the affected product lacks proper authentication. An unauthenticated attacker could access the endpoints, and potentially execute code.
A vulnerability was discovered in Siemens ViewPort for Web Office Portal before revision number 1453 that could allow an unauthenticated remote user to upload arbitrary code and execute it with the permissions of the operating-system user running the web server by sending specially crafted network packets to port 443/TCP or port 80/TCP.
The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime generates predictable authentication tokens for cookies, which makes it easier for remote attackers to bypass authentication via a crafted cookie.
Siemens RUGGEDCOM ROX I (all versions) allow an authenticated user to bypass access restrictions in the web interface at port 10000/TCP to obtain privileged file system access or change configuration settings.
A vulnerability has been identified in SENTRON 7KM PAC3200 (All versions). Affected devices only provide a 4-digit PIN to protect from administrative access via Modbus TCP interface. Attackers with access to the Modbus TCP interface could easily bypass this protection by brute-force attacks or by sniffing the Modbus clear text communication.
A vulnerability has been identified in Siemens APOGEE PXC and TALON TC BACnet Automation Controllers in all versions <V3.5. An attacker with network access to the integrated web server (80/tcp and 443/tcp) could bypass the authentication and download sensitive information from the device.
A vulnerability has been identified in SICAM GridEdge (Classic) (All versions < V2.6.6). The affected application does not require authenticated access for privileged functions. This could allow an unauthenticated attacker to change data of a user, such as credentials, in case that user's id is known.
A vulnerability has been identified in PowerSys (All versions < V3.11). The affected application insufficiently protects responses to authentication requests. This could allow a local attacker to bypass authentication, thereby gaining administrative privileges for the managed remote devices.
A vulnerability was discovered in Siemens SIMATIC WinCC Sm@rtClient for Android (All versions before V1.0.2.2) and SIMATIC WinCC Sm@rtClient for Android Lite (All versions before V1.0.2.2). An attacker with physical access to an unlocked mobile device, that has the affected app running, could bypass the app's authentication mechanism under certain conditions.
An Improper Authentication issue was discovered in Siemens SIMATIC CP 44x-1 RNA, all versions prior to 1.4.1. An unauthenticated remote attacker may be able to perform administrative actions on the Communication Process (CP) of the RNA series module, if network access to Port 102/TCP is available and the configuration file for the CP is stored on the RNA's CPU.
A vulnerability has been identified in SICAM T (All versions < V3.0). Affected devices do not restrict unauthenticated access to certain pages of the web interface. This could allow an attacker to delete log files without authentication.
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02. Attackers with network access to the device's web interface (port 80/tcp) could possibly circumvent authentication and perform certain administrative operations.
ntpd in NTP 4.x before 4.2.8p8 allows remote attackers to cause a denial of service (ephemeral-association demobilization) by sending a spoofed crypto-NAK packet with incorrect authentication data at a certain time.
Siemens SpeedStream 5200 with NetPort Software 1.1 allows remote attackers to bypass authentication via an invalid Host header, possibly involving a trailing dot in the hostname.
A vulnerability has been identified in SiPass integrated V2.76 (All versions), SiPass integrated V2.80 (All versions), SiPass integrated V2.85 (All versions), Siveillance Identity V1.5 (All versions), Siveillance Identity V1.6 (All versions < V1.6.284.0). Affected applications insufficiently limit the access to the internal user authentication service. This could allow an unauthenticated remote attacker to trigger several actions on behalf of valid user accounts.
Siemens SINAMICS S/G controllers with firmware before 4.6.11 do not require authentication for FTP and TELNET sessions, which allows remote attackers to bypass intended access restrictions via TCP traffic to port (1) 21 or (2) 23.
A vulnerability has been identified in SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (V4.5.0). Affected devices fail to authenticate against configured passwords when provisioned using TIA Portal V13. This could allow an attacker using TIA Portal V13 or later versions to bypass authentication and download arbitrary programs to the PLC. The vulnerability does not occur when TIA Portal V13 SP1 or any later version was used to provision the device.
The web server on the Siemens Scalance S Security Module firewall S602 V2, S612 V2, and S613 V2 with firmware before 2.3.0.3 does not limit the rate of authentication attempts, which makes it easier for remote attackers to obtain access via a brute-force attack on the administrative password.
A vulnerability has been identified in SIPORT MP (All versions < 3.2.1). Vulnerable versions of the device could allow an authenticated attacker to impersonate other users of the system and perform (potentially administrative) actions on behalf of those users if the single sign-on feature ("Allow logon without password") is enabled.
NTP 4.x before 4.2.8p6 and 4.3.x before 4.3.90 do not verify peer associations of symmetric keys when authenticating packets, which might allow remote attackers to conduct impersonation attacks via an arbitrary trusted key, aka a "skeleton key."
The TELNET daemon in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not perform authentication, which makes it easier for remote attackers to obtain access via a TCP session.
An issue was discovered in the kernel in NetBSD 7.1. An Access Point (AP) forwards EAPOL frames to other clients even though the sender has not yet successfully authenticated to the AP. This might be abused in projected Wi-Fi networks to launch denial-of-service attacks against connected clients and makes it easier to exploit other vulnerabilities in connected clients.
Siemens SIMATIC HMI Basic Panels 2nd Generation before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Comfort Panels before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Advanced before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Professional before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Basic Panels 1st Generation (WinCC TIA Portal), SIMATIC HMI Mobile Panel 277 (WinCC TIA Portal), SIMATIC HMI Multi Panels (WinCC TIA Portal), and SIMATIC WinCC 7.x before 7.3 Upd4 allow remote attackers to complete authentication by leveraging knowledge of a password hash without knowledge of the associated password.
A vulnerability has been identified in SIMATIC HMI Unified Comfort Panels (All versions <= V16). Affected devices insufficiently validate authentication attempts as the information given can be truncated to match only a set number of characters versus the whole provided string. This could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack.
A vulnerability has been identified in SIMATIC PCS 7 (All versions), SIMATIC WinCC (All versions < V7.5 SP2). Due to an insecure password verification process, an attacker could bypass the password protection set on protected files, thus being granted access to the protected content, circumventing authentication.
Forcepoint Next Generation Firewall (Forcepoint NGFW) 6.4.x before 6.4.7, 6.5.x before 6.5.4, and 6.6.x before 6.6.2 has a serious authentication vulnerability that potentially allows unauthorized users to bypass password authentication and access services protected by the NGFW Engine. The vulnerability affects the following NGFW features when the LDAP authentication method is used as the backend authentication: IPsec VPN, SSL VPN or Browser-based user authentication. The vulnerability does not apply when any other backend authentication is used. The RADIUS authentication method is not vulnerable, for example.
IKEv2 in strongSwan 4.0.7 before 5.1.3 allows remote attackers to bypass authentication by rekeying an IKE_SA during (1) initiation or (2) re-authentication, which triggers the IKE_SA state to be set to established.
CIE.AspNetCore.Authentication is an AspNetCore Remote Authenticator for CIE 3.0. Authentication using Spid and CIE is based on the SAML2 standard which provides two entities: 1. Identity Provider (IDP): the system that authenticates users and provides identity information (SAML affirmation) to the Service Provider, in essence, is responsible for the management of the credentials and identity of users; 2. Service Provider (SP): the system that provides a service to the user and relies on the Identity Provider to authenticate the user, receives SAML assertions from the IdP to grant access to resources. The library cie-aspnetcore refers to the second entity, the SP, and implements the validation logic of SAML assertions within SAML responses. In affected versions there is no guarantee that the first signature refers to the root object, it follows that if an attacker injects an item signed as the first element, all other signatures will not be verified. The only requirement is to have an XML element legitimately signed by the IdP, a condition that is easily met using the IdP's public metadata. An attacker could create an arbitrary SAML response that would be accepted by SPs using vulnerable SDKs, allowing him to impersonate any Spid and/or CIE user. This issue has been addressed in version 2.1.0 and all users are advised to upgrade. There are no known workarounds for this vulnerability.
Cryptographic issue in GPS HLOS Driver while downloading Qualcomm GNSS assistance data.
IBM Aspera HSTS for CP4I 1.5.1 through 1.5.19 is affected by an authentication bypass vulnerability. A transfer client may be able to take advantage of this vulnerability to access files in the server's local storage that they should not have access to, when specific restriction settings are not in place.
`effectindex/tripreporter` is a community-powered, universal platform for submitting and analyzing trip reports. Prior to commit bd80ba833b9023d39ca22e29874296c8729dd53b, any user with an account on an instance of `effectindex/tripreporter`, e.g. `subjective.report`, may be affected by an improper password verification vulnerability. The vulnerability allows any user with a password matching the password requirements to log in as any user. This allows access to accounts / data loss of the user. This issue is patched in commit bd80ba833b9023d39ca22e29874296c8729dd53b. No action necessary for users of `subjective.report`, and anyone running their own instance should update to this commit or newer as soon as possible. As a workaround, someone running their own instance may apply the patch manually.
D-Link DIR-845L router v1.01KRb03 and before is vulnerable to Permission Bypass via the getcfg.php component.
Improper Authentication vulnerability in Mobatime mobile application AMXGT100 allows Authentication Bypass.This issue affects Mobatime mobile application AMXGT100 through 1.3.20.
The Masteriyo LMS WordPress plugin before 2.3.1 does not correctly verify authorization on an unauthenticated AJAX action used to clear user sessions, allowing unauthenticated attackers to terminate the active sessions (force-logout) of any user on the site, including administrators.
The 微信二维码登陆 WordPress plugin through 1.3 does not properly validate WeChat webhook requests, as its signature check always passes, and it discloses the generated login code in the webhook response. This allows an unauthenticated attacker to forge a login event for any existing username, read the login code, and redeem it through an unauthenticated AJAX action to log in as that user, including an administrator, without a password.
maddy is a composable, all-in-one mail server. Starting with version 0.2.0 and prior to version 0.6.3, maddy allows a full authentication bypass if SASL authorization username is specified when using the PLAIN authentication mechanisms. Instead of validating the specified username, it is accepted as is after checking the credentials for the authentication username. maddy 0.6.3 includes the fix for the bug. There are no known workarounds.
Cryptographic issue in Data Modem due to improper authentication during TLS handshake.
IBM Security Guardium 10.0 and 10.1 does not perform an authentication check for a critical resource or functionality allowing anonymous users access to protected areas. IBM X-Force ID: 124685
An authentication bypass vulnerability in Check Point Security Management and Multi-Domain Security Management allows an unauthenticated remote attacker to execute administrative commands on the Management Server. Successful exploitation may also allow command execution on managed Security Gateways. Exploitation requires network access to the Management Server without firewall protection or a configuration that does not restrict Trusted Clients.
Vulnerability in the Oracle Access Manager product of Oracle Fusion Middleware (component: Authentication Engine). Supported versions that are affected are 12.2.1.4.0 and 14.1.2.1.0. Easily exploitable vulnerability allows unauthenticated attacker with network access via HTTP to compromise Oracle Access Manager. Successful attacks of this vulnerability can result in unauthorized creation, deletion or modification access to critical data or all Oracle Access Manager accessible data as well as unauthorized access to critical data or complete access to all Oracle Access Manager accessible data. CVSS 3.1 Base Score 9.1 (Confidentiality and Integrity impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N).
The make_password function in ipsclass.php in Invision Power Board (IPB) 2.1.4 uses random data generated from partially predictable seeds to create the authentication code that is sent by e-mail to a user with a lost password, which might make it easier for remote attackers to guess the code and change the password for an IPB account, possibly involving millions of requests.
IBM QRadar 7.2 does not perform an authentication check for a critical resource or functionality allowing anonymous users access to protected areas. IBM Reference #: 1999545.
A vulnerability was found in wolfSSH's server-side state machine before versions 1.4.17. A malicious client could create channels without first performing user authentication, resulting in unauthorized access.
The N-central server is vulnerable to an authentication bypass of the user interface. This vulnerability is present in all deployments of N-central prior to 2024.2. This vulnerability was discovered through internal N-central source code review and N-able has not observed any exploitation in the wild.
Capgo before 12.128.2 contains a broken authentication vulnerability in its API key generation mechanism. API keys are exposed in frontend requests, and the backend fails to validate that keys are securely generated and bound to the authenticated user. An attacker can tamper with the API key parameter in the generation request and supply arbitrary values, generating custom API keys without proper authorization, which can lead to unauthorized access to protected endpoints.
Flask-AppBuilder is an application development framework, built on top of Flask. When Flask-AppBuilder is set to AUTH_TYPE AUTH_OID, it allows an attacker to forge an HTTP request, that could deceive the backend into using any requested OpenID service. This vulnerability could grant an attacker unauthorised privilege access if a custom OpenID service is deployed by the attacker and accessible by the backend. This vulnerability is only exploitable when the application is using the OpenID 2.0 authorization protocol. Upgrade to Flask-AppBuilder 4.3.11 to fix the vulnerability.
An issue was discovered in WAGO 750-8202/PFC200 prior to FW04 (released August 2015), WAGO 750-881 prior to FW09 (released August 2016), and WAGO 0758-0874-0000-0111. By accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to edit and to view settings without authenticating.
Priority Web version 19.1.0.68, parameter manipulation on an unspecified end-point may allow authentication bypass.