Communication between the client and the server application of the affected products is partially done using CORBA (Common Object Request Broker Architecture) over TCP/IP. This protocol is not encrypted and allows tracing of internal messages. This issue affects * FOXMAN-UN product: FOXMAN-UN R15B, FOXMAN-UN R15A, FOXMAN-UN R14B, FOXMAN-UN R14A, FOXMAN-UN R11B, FOXMAN-UN R11A, FOXMAN-UN R10C, FOXMAN-UN R9C; * UNEM product: UNEM R15B, UNEM R15A, UNEM R14B, UNEM R14A, UNEM R11B, UNEM R11A, UNEM R10C, UNEM R9C. List of CPEs: * cpe:2.3:a:hitachienergy:foxman-un:R15B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R15A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R14B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R14A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R11B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R11A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R10C:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R9C:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R15B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R15A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R14B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R14A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R11B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R11A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R10C:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R9C:*:*:*:*:*:*:*
Concrete CMS Versions 9.0.0 through 9.0.2 and 8.5.7 and below can download zip files over HTTP and execute code from those zip files which could lead to an RCE. Fixed by enforcing ‘concrete_secure’ instead of ‘concrete’. Concrete now only makes requests over https even a request comes in via http. Concrete CMS security team ranked this 8 with CVSS v3.1 vector: AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H Credit goes to Anna for reporting HackerOne 1482520.
3xLOGIC Infinias eIDC32 2.213 devices with Web 1.107 allow Authentication Bypass via CMD.HTM?CMD= because authentication depends on the client side's interpretation of the <KEY>MYKEY</KEY> substring.
Sigma Spectrum Infusion System v's6.x (model 35700BAX) and Baxter Spectrum Infusion System Version(s) 8.x (model 35700BAX2) at the application layer uses an unauthenticated clear-text communication channel to send and receive system status and operational data. This could allow an attacker that has circumvented network security measures to view sensitive non-private data or to perform a man-in-the-middle attack.
A firmware update vulnerability exists in the Firmware Signature Validation functionality of Tenda AC6 V5.0 V02.03.01.110. A specially crafted malicious file can lead to arbitrary code execution. An attacker can provide a malicious file to trigger this vulnerability.
Nautel VX Series transmitters VX SW v6.4.0 and below was discovered to contain a remote code execution (RCE) vulnerability in the firmware update process. This vulnerability allows attackers to execute arbitrary code via supplying a crafted update package to the /#/software/upgrades endpoint.
CloudClassroom-PHP-Project v1.0 is affected by an insecure credential transmission vulnerability. The application transmits passwords over unencrypted HTTP during the login process, exposing sensitive credentials to potential interception by network-based attackers. A remote attacker with access to the same network (e.g., public Wi-Fi or compromised router) can capture login credentials via Man-in-the-Middle (MitM) techniques. If the attacker subsequently uses the credentials to log in and exploit administrative functions (e.g., file upload), this may lead to remote code execution depending on the environment.
The Customer's Tomedo Server in Version 1.7.3 communicates to the Vendor Tomedo Server via HTTP (in cleartext) that can be sniffed by unauthorized actors. Basic authentication is used for the authentication, making it possible to base64 decode the sniffed credentials and discover the username and password.
Certain General Electric Renewable Energy products download firmware without an integrity check. This affects iNET and iNET II before 8.3.0, SD before 6.4.7, TD220X before 2.0.16, and TD220MAX before 1.2.6.
The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower stores and transmits the credentials of third-party services in cleartext.
In Ruckus R310 10.5.1.0.199, Ruckus R500 10.5.1.0.199, Ruckus R600 10.5.1.0.199, Ruckus T300 10.5.1.0.199, Ruckus T301n 10.5.1.0.199, Ruckus T301s 10.5.1.0.199, SmartCell Gateway 200 (SCG200) before 3.6.2.0.795, SmartZone 100 (SZ-100) before 3.6.2.0.795, SmartZone 300 (SZ300) before 3.6.2.0.795, Virtual SmartZone (vSZ) before 3.6.2.0.795, ZoneDirector 1100 9.10.2.0.130, ZoneDirector 1200 10.2.1.0.218, ZoneDirector 3000 10.2.1.0.218, ZoneDirector 5000 10.0.1.0.151, a vulnerability allows attackers to bypass firmware image bad md5 checksum failed error.
In Ruckus R310 10.5.1.0.199, Ruckus R500 10.5.1.0.199, Ruckus R600 10.5.1.0.199, Ruckus T300 10.5.1.0.199, Ruckus T301n 10.5.1.0.199, Ruckus T301s 10.5.1.0.199, SmartCell Gateway 200 (SCG200) before 3.6.2.0.795, SmartZone 100 (SZ-100) before 3.6.2.0.795, SmartZone 300 (SZ300) before 3.6.2.0.795, Virtual SmartZone (vSZ) before 3.6.2.0.795, ZoneDirector 1100 9.10.2.0.130, ZoneDirector 1200 10.2.1.0.218, ZoneDirector 3000 10.2.1.0.218, ZoneDirector 5000 10.0.1.0.151, a vulnerability allows attackers to switch completely to unauthorized image to be Boot as primary verified image.
An issue was discovered on HUMAX HGA12R-02 BRGCAA 1.1.53 devices. A vulnerability in the authentication functionality in the web-based interface could allow an unauthenticated remote attacker to capture packets at the time of authentication and gain access to the cleartext password. An attacker could use this access to create a new user account or control the device.
An incomplete SSL server certification validation vulnerability in the Trend Micro Security 2019 (v15) consumer family of products could allow an attacker to combine this vulnerability with another attack to trick an affected client into downloading a malicious update instead of the expected one. CWE-494: Update files are not properly verified.
The affected product is vulnerable due to cleartext transmission of credentials seen in the CIMPLICITY network, which can be easily spoofed and used to log in to make operational changes to the system.
Barco wePresent WiPG-1600W devices download code without an Integrity Check. Affected Version(s): 2.5.1.8, 2.5.0.25, 2.5.0.24, 2.4.1.19. The Barco wePresent WiPG-1600W firmware does not perform verification of digitally signed firmware updates and is susceptible to processing and installing modified/malicious images.
The vulnerability exists in TP-Link TL-WR841N V11 3.16.9 Build 160325 Rel.62500n wireless router due to transmission of authentication information in cleartextbase64 format. Successful exploitation of this vulnerability could allow a remote attacker to intercept credentials and subsequently perform administrative operations on the affected device through web-based management interface.
Technicolor TC7337NET 08.89.17.23.03 devices allow remote attackers to discover passwords by sniffing the network for an "Authorization: Basic" HTTP header.
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow'), Out-of-bounds Write, Download of Code Without Integrity Check vulnerability in Silicon Labs Gecko Bootloader on ARM (Firmware Update File Parser modules) allows Code Injection, Authentication Bypass.This issue affects "Standalone" and "Application" versions of Gecko Bootloader.
Moxa IKS-G6824A series Versions 4.5 and prior, EDS-405A series Version 3.8 and prior, EDS-408A series Version 3.8 and prior, and EDS-510A series Version 3.8 and prior use plaintext transmission of sensitive data, which may allow an attacker to capture sensitive data such as an administrative password.
Synel Terminals - CWE-494: Download of Code Without Integrity Check
Shenzen Tenda Technology IP Camera CP3 V11.10.00.2211041355 does not defend against physical access to U-Boot via the UART: the Wi-Fi password is shown, and the hardcoded boot password can be inserted for console access.
An issue was discovered in Emote Remote Mouse through 4.0.0.0. Attackers can maximize or minimize the window of a running process by sending the process name in a crafted packet. This information is sent in cleartext and is not protected by any authentication logic.
Jenkins Plugin Installation Manager Tool 2.1.3 and earlier does not verify plugin downloads.
Video Insight VMS versions prior to 7.8 allows a remote attacker to execute arbitrary code with the system user privilege by sending a specially crafted request.
Rubetek SmartHome 2020 devices use unencrypted 433 MHz communication between controllers and beacons, allowing an attacker to sniff and spoof beacon requests remotely.
EyeSurfer BflyInstallerX.ocx v1.0.0.16 and earlier versions contain a vulnerability that could allow remote files to be download by setting the arguments to the vulnerable method. This can be leveraged for code execution. When the vulnerable method is called, they fail to properly check the parameters that are passed to it.
SAP Solution Manager (Diagnostics Agent), version 720, allows unencrypted connections from unauthenticated sources. This allows an attacker to control all remote functions on the Agent due to Missing Authentication Check.
Scheduler for TAS prior to version 1.4.0 was permitting plaintext transmission of UAA client token by sending it over a non-TLS connection. This also depended on the configuration of the MySQL server which is used to cache a UAA client token used by the service. If intercepted the token can give an attacker admin level access in the cloud controller.
Last Yard 22.09.8-1 does not enforce HSTS headers