A vulnerability in the web-based management interface of ClearPass Policy Manager could allow an unauthenticated remote attacker to create arbitrary users on the platform. A successful exploit allows an attacker to achieve total cluster compromise.
A vulnerability has been discovered in the customer-managed ShareFile storage zones controller which, if exploited, could allow an unauthenticated attacker to remotely compromise the customer-managed ShareFile storage zones controller.
D-Link - CWE-288:Authentication Bypass Using an Alternate Path or Channel
An authentication bypass vulnerability exists in the httpd nvram.cgi functionality of Yifan YF325 v1.0_20221108. A specially crafted network request can lead to arbitrary command execution. An attacker can send a network request to trigger this vulnerability.
An access control issue in Axcora POS #0~gitf77ec09 allows unauthenticated attackers to execute arbitrary commands via unspecified vectors.
Improper Access Control in GitHub repository thorsten/phpmyfaq prior to 3.1.13.
HGiga PowerStation has a vulnerability of Information Leakage. An unauthenticated remote attacker can exploit this vulnerability to obtain the administrator's credential. This credential can then be used to login PowerStation or Secure Shell to achieve remote code execution.
The system application (com.transsion.kolun.aiservice) component does not perform an authentication check, which allows attackers to perform malicious exploitations and affect system services.
Broken access control in Advanced Authentication versions prior to 6.4.1.1 and 6.3.7.2
The Flexi Classic and Flexi Soft Gateways SICK UE410-EN3 FLEXI ETHERNET GATEW. with serial number <=2311xxxx all Firmware versions, SICK UE410-EN1 FLEXI ETHERNET GATEW. with serial number <=2311xxxx all Firmware versions, SICK UE410-EN3S04 FLEXI ETHERNET GATEW. with serial number <=2311xxxx all Firmware versions, SICK UE410-EN4 FLEXI ETHERNET GATEW. with serial number <=2311xxxx all Firmware versions, SICK FX0-GENT00000 FLEXISOFT EIP GATEW. with serial number <=2311xxxx with Firmware <=V2.11.0, SICK FX0-GMOD00000 FLEXISOFT MOD GATEW. with serial number <=2311xxxx with Firmware <=V2.11.0, SICK FX0-GPNT00000 FLEXISOFT PNET GATEW. with serial number <=2311xxxx with Firmware <=V2.12.0, SICK FX0-GENT00030 FLEXISOFT EIP GATEW.V2 with serial number <=2311xxxx all Firmware versions, SICK FX0-GPNT00030 FLEXISOFT PNET GATEW.V2 with serial number <=2311xxxx all Firmware versions and SICK FX0-GMOD00010 FLEXISOFT MOD GW with serial number <=2311xxxx with Firmware <=V2.11.0 all have Telnet enabled by factory default. No password is set in the default configuration.
Microsoft SQL Server Elevation of Privilege Vulnerability
An issue regarding missing authentication for certain utilities exists in CyberPower PowerPanel Enterprise prior to v2.8.3. An unauthenticated remote attacker can access the PDNU REST APIs, which may result in compromise of the application.
Missing Authentication for Critical Function in SICK FX0-GPNT v3 Firmware Version V3.04 and V3.05 allows an unprivileged remote attacker to achieve arbitrary remote code execution via maliciously crafted RK512 commands to the listener on TCP port 9000.
Infoblox NIOS through 8.6.4 has Improper Authentication for Grids.
A security misconfiguration vulnerability exists in the Zyxel LTE3316-M604 firmware version V2.00(ABMP.6)C0 due to a factory default misconfiguration intended for testing purposes. A remote attacker could leverage this vulnerability to access an affected device using Telnet.
SICK Package Analytics software up to and including version V04.0.0 are vulnerable to an authentication bypass by directly interfacing with the REST API. An attacker can send unauthorized requests, bypass current authentication controls presented by the application and could potentially write files without authentication.
Missing Authentication for Critical Function in SICK FX0-GENT v3 Firmware Version V3.04 and V3.05 allows an unprivileged remote attacker to achieve arbitrary remote code execution via maliciously crafted RK512 commands to the listener on TCP port 9000.
In MISP 2.4.167, app/Controller/Component/ACLComponent.php has incorrect access control for the decaying import function.
Baicells Nova 227, Nova 233, and Nova 243 LTE TDD eNodeB devices with firmware through RTS/RTD 3.7.11.3 have hardcoded credentials that are easily discovered and can be used by remote attackers to authenticate via ssh. (The credentials are stored in the firmware, encrypted by the crypt function.)
An incorrect access control vulnerability in Rubrik CDM versions prior to 9.1.2-p1, 9.0.3-p6 and 8.1.3-p12, allows an attacker with network access to execute arbitrary code.
Vulnerability in the Oracle WebLogic Server product of Oracle Fusion Middleware (component: Core). The supported version that is affected is 12.2.1.3.0. Easily exploitable vulnerability allows unauthenticated attacker with network access via T3, IIOP to compromise Oracle WebLogic Server. Successful attacks of this vulnerability can result in takeover of Oracle WebLogic Server. CVSS 3.1 Base Score 9.8 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
TOTOLINK CP900L v4.1.5cu.798_B20221228 was discovered to contain a hardcoded password for telnet in /web_cste/cgi-bin/product.ini, which allows attackers to log in as root.
Vulnerability in the Oracle WebLogic Server product of Oracle Fusion Middleware (component: Core). Supported versions that are affected are 12.2.1.4.0 and 14.1.1.0.0. Easily exploitable vulnerability allows unauthenticated attacker with network access via T3, IIOP to compromise Oracle WebLogic Server. Successful attacks of this vulnerability can result in takeover of Oracle WebLogic Server. CVSS 3.1 Base Score 9.8 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
LS ELECTRIC XBC-DN32U with operating system version 01.80 does not properly control access to the PLC over its internal XGT protocol. An attacker could control and tamper with the PLC by sending the packets to the PLC over its XGT protocol.
LS ELECTRIC XBC-DN32U with operating system version 01.80 is missing authentication to create users on the PLC. This could allow an attacker to create and use an account with elevated privileges and take control of the device.
A vulnerability, which was classified as critical, was found in MAXTECH MAX-G866ac 0.4.1_TBRO_20160314. This affects an unknown part of the component Remote Management. The manipulation leads to missing authentication. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-227001 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Multiple vulnerabilities in Cisco Nexus Dashboard could allow an unauthenticated, remote attacker to execute arbitrary commands, read or upload container image files, or perform a cross-site request forgery attack. For more information about these vulnerabilities, see the Details section of this advisory.
Axiros AXESS Auto Configuration Server (ACS) 4.x and 5.0.0 is affected by an Incorrect Access Control vulnerability. An authorization bypass allows remote attackers to achieve unauthenticated remote code execution.
include/functions_installer.inc.php in Serendipity through 2.0.5 is vulnerable to File Inclusion and a possible Code Execution attack during a first-time installation because it fails to sanitize the dbType POST parameter before adding it to an include() call in the bundled-libs/serendipity_generateFTPChecksums.php file.
IBM WebSphere Application Server (WAS) 7.0 before 7.0.0.5 does not properly read the portletServingEnabled parameter in ibm-portlet-ext.xmi, which allows remote attackers to bypass intended access restrictions via unknown vectors.
A vulnerability in the web-based management interface of Cisco SPA112 2-Port Phone Adapters could allow an unauthenticated, remote attacker to execute arbitrary code on an affected device. This vulnerability is due to a missing authentication process within the firmware upgrade function. An attacker could exploit this vulnerability by upgrading an affected device to a crafted version of firmware. A successful exploit could allow the attacker to execute arbitrary code on the affected device with full privileges. Cisco has not released firmware updates to address this vulnerability.
admin.php in Frax.dk Php Recommend 1.3 and earlier does not require authentication when the user password is changed, which allows remote attackers to gain administrative privileges via modified form_admin_user and form_admin_pass parameters.
An issue in flusity CMS v2.33 allows a remote attacker to execute arbitrary code via the add_addon.php component.
A vulnerability classified as critical was found in SourceCodester Online Pizza Ordering System 1.0. Affected by this vulnerability is the function delete_category of the file ajax.php of the component POST Parameter Handler. The manipulation leads to missing authentication. The attack can be launched remotely. The associated identifier of this vulnerability is VDB-221455.
A vulnerability classified as critical has been found in Software AG WebMethods 10.11.x/10.15.x. Affected is an unknown function of the file wm.server/connect/. The manipulation leads to improper access controls. It is possible to launch the attack remotely. To access a file like /assets/ a popup may request username and password. By just clicking CANCEL you will be redirected to the directory. If you visited /invoke/wm.server/connect, you'll be able to see details like internal IPs, ports, and versions. In some cases if access to /assets/ is refused, you may enter /assets/x as a wrong value, then come back to /assets/ which we will show the requested data. It appears that insufficient access control is depending on referrer header data. VDB-247158 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
An unauthenticated remote attacker who is aware of a MQTT topic name can send and receive messages, including GET/SET configuration commands, reboot commands and firmware updates.
SnapCenter versions 4.7 prior to 4.7P2 and 4.8 prior to 4.8P1 are susceptible to a vulnerability which could allow a remote unauthenticated attacker to gain access as an admin user.
A vulnerability was found in SourceCodester Music Gallery Site 1.0. It has been rated as critical. This issue affects some unknown processing of the file Users.php of the component POST Request Handler. The manipulation leads to improper access controls. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-221633 was assigned to this vulnerability.
A vulnerability was found in SourceCodester Online Food Ordering System 2.0 and classified as critical. Affected by this issue is some unknown functionality of the file /fos/admin/ajax.php?action=save_settings of the component POST Request Handler. The manipulation leads to improper access controls. The attack may be launched remotely. VDB-223214 is the identifier assigned to this vulnerability.
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability that could allow an attacker to achieve unauthenticated remote code execution in the context of an administrator.
Improper Access Control in GitHub repository answerdev/answer prior to 1.0.4.
The UI in DevSpace 4.13.0 allows web sites to execute actions on pods (on behalf of a victim) because of a lack of authentication for the WebSocket protocol. This leads to remote code execution.
SAUTER Controls Nova 200–220 Series with firmware version 3.3-006 and prior and BACnetstac version 4.2.1 and prior allows the execution of commands without credentials. As Telnet and file transfer protocol (FTP) are the only protocols available for device management, an unauthorized user could access the system and modify the device configuration, which could result in the unauthorized user executing unrestricted malicious commands.
An unauthenticated attacker in SAP NetWeaver AS for Java - version 7.50, due to improper access control, can attach to an open interface and make use of an open naming and directory API to access services which can be used to perform unauthorized operations affecting users and data on the current system. This could allow the attacker to have full read access to user data, make modifications to user data, and make services within the system unavailable.
Grandstream GRP261x VoIP phone running firmware version 1.0.3.6 (Base) allow Authentication Bypass in its administrative web interface.
It is possible to enumerate access card credentials via an unauthenticated network connection to the server in versions of Command Centre v8.20 prior to v8.20.1166(MR3), versions of 8.10 prior to v8.10.1211(MR5), versions of 8.00 prior to v8.00.1228(MR6), all versions of 7.90 and earlier. These credentials can then be used to encode low security cards to be used by the system where insecure card technologies are supported.
The Alfresco Reset Password add-on before version 1.2.0 relies on untrusted inputs in a security decision. Intruders can get admin's access to the system using the vulnerability in the project. Impacts all servers where this add-on is installed. The problem is fixed in version 1.2.0
COMFAST (Shenzhen Sihai Zhonglian Network Technology Co., Ltd) CF-WR623N Router firmware V2.3.0.1 is vulnerable to Incorrect Access Control.
Improper Access Control in GitHub repository ikus060/rdiffweb prior to 2.5.5.
A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046)