4Vulnerabilities found

CVE-2019-25678
Assigner-VulnCheck
ShareView Details
Assigner-VulnCheck
CVSS Score-8.8||HIGH
EPSS-0.08% / 22.61%
||
7 Day CHG+0.02%
Published-05 Apr, 2026 | 20:45
Updated-20 Apr, 2026 | 17:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
C4G BLIS 3.4 SQL Injection via users_select.php

C4G Basic Laboratory Information System 3.4 contains multiple SQL injection vulnerabilities that allow unauthenticated attackers to execute arbitrary SQL commands by injecting malicious code through the site parameter. Attackers can send GET requests to the users_select.php endpoint with crafted SQL payloads to extract sensitive database information including patient records and system credentials.

Action-Not Available
Vendor-gatechC4G
Product-computing_for_good\'s_basic_laboratory_information_systemBasic Laboratory Information System
CWE ID-CWE-306
Missing Authentication for Critical Function
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2019-5644
Assigner-Rapid7, Inc.
ShareView Details
Assigner-Rapid7, Inc.
CVSS Score-10||CRITICAL
EPSS-1.91% / 83.38%
||
7 Day CHG~0.00%
Published-06 Nov, 2019 | 18:30
Updated-16 Sep, 2024 | 22:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
C4G BLIS Improper Access Control

Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.5 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may alter several facets of a user account, including promoting any user to an administrator.

Action-Not Available
Vendor-gatechComputing For Good
Product-computing_for_good\'s_basic_laboratory_information_systemBasic Laboratory Information System
CWE ID-CWE-284
Improper Access Control
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-5643
Assigner-Rapid7, Inc.
ShareView Details
Assigner-Rapid7, Inc.
CVSS Score-5.3||MEDIUM
EPSS-0.84% / 74.78%
||
7 Day CHG~0.00%
Published-06 Nov, 2019 | 18:30
Updated-16 Sep, 2024 | 19:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
C4G BLIS Improper Access Control

Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.5 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may enumerate the user names and facility names in use on a particular installation.

Action-Not Available
Vendor-gatechComputing For Good
Product-computing_for_good\'s_basic_laboratory_information_systemBasic Laboratory Information System
CWE ID-CWE-284
Improper Access Control
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-5617
Assigner-Rapid7, Inc.
ShareView Details
Assigner-Rapid7, Inc.
CVSS Score-10||CRITICAL
EPSS-1.91% / 83.38%
||
7 Day CHG~0.00%
Published-06 Nov, 2019 | 18:30
Updated-17 Sep, 2024 | 02:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
C4G BLIS Improper Access Control

Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.4 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may change the password of any administrator-level user.

Action-Not Available
Vendor-gatechComputing For Good
Product-computing_for_good\'s_basic_laboratory_information_systemBasic Laboratory Information System
CWE ID-CWE-284
Improper Access Control
CWE ID-CWE-306
Missing Authentication for Critical Function