UltraVNC revision 1206 has stack-based Buffer overflow vulnerability in VNC client code inside FileTransfer module, which leads to a denial of service (DoS) condition. This attack appear to be exploitable via network connectivity. This vulnerability has been fixed in revision 1207.
Siemens SIMATIC S7-400 PN CPU devices with firmware 6 before 6.0.3 allow remote attackers to cause a denial of service (defect-mode transition and service outage) via crafted ICMP packets.
Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to TCP port 102 (aka the ISO-TSAP port).
A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions < V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R family (All versions < V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Upd 4), SINEC NMS (All versions < V1.0 SP1), SINEMA Server (All versions < V14 SP2), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions < V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication.
A vulnerability has been identified in SINAMICS PERFECT HARMONY GH180 with NXG I control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- (All Versions with option G28), SINAMICS PERFECT HARMONY GH180 with NXG II control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- (All Versions with option G28). A denial of service vulnerability exists in the affected products. The vulnerability could be exploited by an attacker with network access to the device. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SIMATIC CP 343-1 (6GK7343-1EX30-0XE0) (All versions), SIMATIC CP 343-1 Lean (6GK7343-1CX10-0XE0) (All versions), SIPLUS NET CP 343-1 (6AG1343-1EX30-7XE0) (All versions), SIPLUS NET CP 343-1 Lean (6AG1343-1CX10-2XE0) (All versions). Affected products incorrectly validate TCP sequence numbers. This could allow an unauthenticated remote attacker to create a denial of service condition by injecting spoofed TCP RST packets.
UltraVNC revision 1211 has a stack buffer overflow vulnerability in VNC server code inside file transfer request handler, which can result in Denial of Service (DoS). This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212.
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V2.7). The affected application allows IP configuration change without authentication to the device. This could allow an attacker to cause denial of service condition.
A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an improper input validation vulnerability that could allow an attacker to bring the service into a Denial-of-Service state by sending a specifically crafted message to 4004/tcp. The corresponding service is auto-restarted after the crash is detected by a watchdog.
A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash.
A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp and 4004/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash.
Affected devices improperly handle specially crafted packets sent to port 102/tcp. This could allow an attacker to create a denial of service condition. A restart is needed to restore normal operations.
The Diffie-Hellman Key Agreement Protocol allows remote attackers (from the client side) to send arbitrary numbers that are actually not public keys, and trigger expensive server-side DHE modular-exponentiation calculations, aka a D(HE)at or D(HE)ater attack. The client needs very little CPU resources and network bandwidth. The attack may be more disruptive in cases where a client can require a server to select its largest supported key size. The basic attack scenario is that the client must claim that it can only communicate with DHE, and the server must be configured to allow DHE.
A vulnerability has been identified in SIPROTEC 5 6MD85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 6MD86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 6MD89 (CP300) (All versions >= V7.80 < V9.64), SIPROTEC 5 6MU85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7KE85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SA82 (CP100) (All versions), SIPROTEC 5 7SA82 (CP150) (All versions < V9.40), SIPROTEC 5 7SA86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SA87 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SD82 (CP100) (All versions), SIPROTEC 5 7SD82 (CP150) (All versions < V9.40), SIPROTEC 5 7SD86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SD87 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SJ81 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.40), SIPROTEC 5 7SJ82 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.40), SIPROTEC 5 7SJ85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SJ86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SK82 (CP100) (All versions < V8.89), SIPROTEC 5 7SK82 (CP150) (All versions < V9.40), SIPROTEC 5 7SK85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SL82 (CP100) (All versions), SIPROTEC 5 7SL82 (CP150) (All versions < V9.40), SIPROTEC 5 7SL86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SL87 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SS85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7ST85 (CP300) (All versions >= V7.80 < V9.64), SIPROTEC 5 7ST86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SX82 (CP150) (All versions < V9.40), SIPROTEC 5 7SX85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7UM85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7UT82 (CP100) (All versions), SIPROTEC 5 7UT82 (CP150) (All versions < V9.40), SIPROTEC 5 7UT85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7UT86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7UT87 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7VE85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7VK87 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7VU85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 Communication Module ETH-BA-2EL (All versions < V9.40 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BA-2EL (All versions < V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (All versions < V9.40 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (All versions < V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions < V9.40), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V9.40). Affected devices lack proper validation of http request parameters of the hosted web service. An unauthenticated remote attacker could send specially crafted packets that could cause denial of service condition of the target device.
The OPC UA implementations (ANSI C and C++) in affected products contain an integer overflow vulnerability that could cause the application to run into an infinite loop during certificate validation. This could allow an unauthenticated remote attacker to create a denial of service condition by sending a specially crafted certificate.
An issue was discovered in LibVNCServer before 0.9.13. libvncserver/ws_decode.c can lead to a crash because of unaligned accesses in hybiReadAndDecode.
A vulnerability has been identified in SIPROTEC 4 and SIPROTEC Compact relays equipped with EN100 Ethernet communication modules (All versions). Specially crafted packets sent to port 50000/UDP of the EN100 Ethernet communication modules could cause a Denial-of-Service of the affected device. A manual reboot is required to recover the service of the device. At the time of advisory publication no public exploitation of this security vulnerability was known to Siemens.
flattenSubquery in select.c in SQLite 3.30.1 mishandles certain uses of SELECT DISTINCT involving a LEFT JOIN in which the right-hand side is a view. This can cause a NULL pointer dereference (or incorrect results).
zipfileUpdate in ext/misc/zipfile.c in SQLite 3.30.1 mishandles a NULL pathname during an update of a ZIP archive.
A vulnerability has been identified in OpenPCS 7 V8.1 (All versions), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd3), SIMATIC BATCH V8.1 (All versions), SIMATIC BATCH V8.2 (All versions < V8.2 Upd12), SIMATIC BATCH V9.0 (All versions < V9.0 SP1 Upd5), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Update 1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions < V9.0 Upd4), SIMATIC WinCC (TIA Portal) V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC (TIA Portal) V15.1 (All versions < V15.1 Update 5), SIMATIC WinCC (TIA Portal) V16 (All versions < V16 Update 1), SIMATIC WinCC V7.3 (All versions), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 1). Through specially crafted messages, when encrypted communication is enabled, an attacker with network access could use the vulnerability to compromise the availability of the system by causing a Denial-of-Service condition. Successful exploitation requires no system privileges and no user interaction.
Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device.
Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device.
A vulnerability has been identified in SIMATIC eaSie Core Package (All versions < V22.00). The affected systems do not properly validate input that is sent to the underlying message passing framework. This could allow an remote attacker to trigger a denial of service of the affected system.
Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device.
The in-memory certificate cache in strongSwan before 5.9.4 has a remote integer overflow upon receiving many requests with different certificates to fill the cache and later trigger the replacement of cache entries. The code attempts to select a less-often-used cache entry by means of a random number generator, but this is not done correctly. Remote code execution might be a slight possibility.
The webserver of the affected devices contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device.
A vulnerability has been identified in SIMATIC Reader RF610R CMIIT (6GT2811-6BC10-2AA0) (All versions < V4.2), SIMATIC Reader RF610R ETSI (6GT2811-6BC10-0AA0) (All versions < V4.2), SIMATIC Reader RF610R FCC (6GT2811-6BC10-1AA0) (All versions < V4.2), SIMATIC Reader RF615R CMIIT (6GT2811-6CC10-2AA0) (All versions < V4.2), SIMATIC Reader RF615R ETSI (6GT2811-6CC10-0AA0) (All versions < V4.2), SIMATIC Reader RF615R FCC (6GT2811-6CC10-1AA0) (All versions < V4.2), SIMATIC Reader RF650R ARIB (6GT2811-6AB20-4AA0) (All versions < V4.2), SIMATIC Reader RF650R CMIIT (6GT2811-6AB20-2AA0) (All versions < V4.2), SIMATIC Reader RF650R ETSI (6GT2811-6AB20-0AA0) (All versions < V4.2), SIMATIC Reader RF650R FCC (6GT2811-6AB20-1AA0) (All versions < V4.2), SIMATIC Reader RF680R ARIB (6GT2811-6AA10-4AA0) (All versions < V4.2), SIMATIC Reader RF680R CMIIT (6GT2811-6AA10-2AA0) (All versions < V4.2), SIMATIC Reader RF680R ETSI (6GT2811-6AA10-0AA0) (All versions < V4.2), SIMATIC Reader RF680R FCC (6GT2811-6AA10-1AA0) (All versions < V4.2), SIMATIC Reader RF685R ARIB (6GT2811-6CA10-4AA0) (All versions < V4.2), SIMATIC Reader RF685R CMIIT (6GT2811-6CA10-2AA0) (All versions < V4.2), SIMATIC Reader RF685R ETSI (6GT2811-6CA10-0AA0) (All versions < V4.2), SIMATIC Reader RF685R FCC (6GT2811-6CA10-1AA0) (All versions < V4.2), SIMATIC RF1140R (6GT2831-6CB00) (All versions < V1.1), SIMATIC RF1170R (6GT2831-6BB00) (All versions < V1.1), SIMATIC RF166C (6GT2002-0EE20) (All versions < V2.2), SIMATIC RF185C (6GT2002-0JE10) (All versions < V2.2), SIMATIC RF186C (6GT2002-0JE20) (All versions < V2.2), SIMATIC RF186CI (6GT2002-0JE50) (All versions < V2.2), SIMATIC RF188C (6GT2002-0JE40) (All versions < V2.2), SIMATIC RF188CI (6GT2002-0JE60) (All versions < V2.2), SIMATIC RF360R (6GT2801-5BA30) (All versions < V2.2). The affected devices does not properly handle the error in case of exceeding characters while setting SNMP leading to the restart of the application.
A vulnerability has been identified in SINAMICS PERFECT HARMONY GH180 with NXG I control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- (All Versions with option G21, G22, G23, G26, G28, G31, G32, G38, G43 or G46), SINAMICS PERFECT HARMONY GH180 with NXG II control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- (All Versions with option G21, G22, G23, G26, G28, G31, G32, G38, G43 or G46). An improperly configured Parameter Read/Write execution via Field bus network may cause the controller to restart. The vulnerability could be exploited by an attacker with network access to the device. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise the availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.
The gmp plugin in strongSwan before 5.9.4 has a remote integer overflow via a crafted certificate with an RSASSA-PSS signature. For example, this can be triggered by an unrelated self-signed CA certificate sent by an initiator. Remote code execution cannot occur.
A vulnerability has been identified in Desigo DXR2 (All versions < V01.21.142.5-22), Desigo PXC3 (All versions < V01.21.142.4-18), Desigo PXC4 (All versions < V02.20.142.10-10884), Desigo PXC5 (All versions < V02.20.142.10-10884). When the controller receives a specific BACnet protocol packet, an exception causes the BACnet communication function to go into a “out of work” state and could result in the controller going into a “factory reset” state.
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.14.1), RUGGEDCOM ROX RX1400 (All versions < V2.14.1), RUGGEDCOM ROX RX1500 (All versions < V2.14.1), RUGGEDCOM ROX RX1501 (All versions < V2.14.1), RUGGEDCOM ROX RX1510 (All versions < V2.14.1), RUGGEDCOM ROX RX1511 (All versions < V2.14.1), RUGGEDCOM ROX RX1512 (All versions < V2.14.1), RUGGEDCOM ROX RX1524 (All versions < V2.14.1), RUGGEDCOM ROX RX1536 (All versions < V2.14.1), RUGGEDCOM ROX RX5000 (All versions < V2.14.1). Affected devices write crashdumps without checking if enough space is available on the filesystem. Once the crashdump fills the entire root filesystem, affected devices fail to boot successfully. An attacker can leverage this vulnerability to cause a permanent Denial-of-Service.
A vulnerability has been identified in RUGGEDCOM i800, RUGGEDCOM i800NC, RUGGEDCOM i801, RUGGEDCOM i801NC, RUGGEDCOM i802, RUGGEDCOM i802NC, RUGGEDCOM i803, RUGGEDCOM i803NC, RUGGEDCOM M2100, RUGGEDCOM M2100NC, RUGGEDCOM M2200, RUGGEDCOM M2200NC, RUGGEDCOM M969, RUGGEDCOM M969NC, RUGGEDCOM RMC30, RUGGEDCOM RMC30NC, RUGGEDCOM RMC8388 V4.X, RUGGEDCOM RMC8388 V5.X, RUGGEDCOM RMC8388NC V4.X, RUGGEDCOM RMC8388NC V5.X, RUGGEDCOM RP110, RUGGEDCOM RP110NC, RUGGEDCOM RS1600, RUGGEDCOM RS1600F, RUGGEDCOM RS1600FNC, RUGGEDCOM RS1600NC, RUGGEDCOM RS1600T, RUGGEDCOM RS1600TNC, RUGGEDCOM RS400, RUGGEDCOM RS400NC, RUGGEDCOM RS401, RUGGEDCOM RS401NC, RUGGEDCOM RS416, RUGGEDCOM RS416NC, RUGGEDCOM RS416NCv2 V4.X, RUGGEDCOM RS416NCv2 V5.X, RUGGEDCOM RS416P, RUGGEDCOM RS416PNC, RUGGEDCOM RS416PNCv2 V4.X, RUGGEDCOM RS416PNCv2 V5.X, RUGGEDCOM RS416Pv2 V4.X, RUGGEDCOM RS416Pv2 V5.X, RUGGEDCOM RS416v2 V4.X, RUGGEDCOM RS416v2 V5.X, RUGGEDCOM RS8000, RUGGEDCOM RS8000A, RUGGEDCOM RS8000ANC, RUGGEDCOM RS8000H, RUGGEDCOM RS8000HNC, RUGGEDCOM RS8000NC, RUGGEDCOM RS8000T, RUGGEDCOM RS8000TNC, RUGGEDCOM RS900, RUGGEDCOM RS900 (32M) V4.X, RUGGEDCOM RS900 (32M) V5.X, RUGGEDCOM RS900G, RUGGEDCOM RS900G (32M) V4.X, RUGGEDCOM RS900G (32M) V5.X, RUGGEDCOM RS900GNC, RUGGEDCOM RS900GNC(32M) V4.X, RUGGEDCOM RS900GNC(32M) V5.X, RUGGEDCOM RS900GP, RUGGEDCOM RS900GPNC, RUGGEDCOM RS900L, RUGGEDCOM RS900LNC, RUGGEDCOM RS900M-GETS-C01, RUGGEDCOM RS900M-GETS-XX, RUGGEDCOM RS900M-STND-C01, RUGGEDCOM RS900M-STND-XX, RUGGEDCOM RS900MNC-GETS-C01, RUGGEDCOM RS900MNC-GETS-XX, RUGGEDCOM RS900MNC-STND-XX, RUGGEDCOM RS900MNC-STND-XX-C01, RUGGEDCOM RS900NC, RUGGEDCOM RS900NC(32M) V4.X, RUGGEDCOM RS900NC(32M) V5.X, RUGGEDCOM RS900W, RUGGEDCOM RS910, RUGGEDCOM RS910L, RUGGEDCOM RS910LNC, RUGGEDCOM RS910NC, RUGGEDCOM RS910W, RUGGEDCOM RS920L, RUGGEDCOM RS920LNC, RUGGEDCOM RS920W, RUGGEDCOM RS930L, RUGGEDCOM RS930LNC, RUGGEDCOM RS930W, RUGGEDCOM RS940G, RUGGEDCOM RS940GNC, RUGGEDCOM RS969, RUGGEDCOM RS969NC, RUGGEDCOM RSG2100, RUGGEDCOM RSG2100 (32M) V4.X, RUGGEDCOM RSG2100 (32M) V5.X, RUGGEDCOM RSG2100NC, RUGGEDCOM RSG2100NC(32M) V4.X, RUGGEDCOM RSG2100NC(32M) V5.X, RUGGEDCOM RSG2100P, RUGGEDCOM RSG2100P (32M) V4.X, RUGGEDCOM RSG2100P (32M) V5.X, RUGGEDCOM RSG2100PNC, RUGGEDCOM RSG2100PNC (32M) V4.X, RUGGEDCOM RSG2100PNC (32M) V5.X, RUGGEDCOM RSG2200, RUGGEDCOM RSG2200NC, RUGGEDCOM RSG2288 V4.X, RUGGEDCOM RSG2288 V5.X, RUGGEDCOM RSG2288NC V4.X, RUGGEDCOM RSG2288NC V5.X, RUGGEDCOM RSG2300 V4.X, RUGGEDCOM RSG2300 V5.X, RUGGEDCOM RSG2300NC V4.X, RUGGEDCOM RSG2300NC V5.X, RUGGEDCOM RSG2300P V4.X, RUGGEDCOM RSG2300P V5.X, RUGGEDCOM RSG2300PNC V4.X, RUGGEDCOM RSG2300PNC V5.X, RUGGEDCOM RSG2488 V4.X, RUGGEDCOM RSG2488 V5.X, RUGGEDCOM RSG2488NC V4.X, RUGGEDCOM RSG2488NC V5.X, RUGGEDCOM RSG907R, RUGGEDCOM RSG908C, RUGGEDCOM RSG909R, RUGGEDCOM RSG910C, RUGGEDCOM RSG920P V4.X, RUGGEDCOM RSG920P V5.X, RUGGEDCOM RSG920PNC V4.X, RUGGEDCOM RSG920PNC V5.X, RUGGEDCOM RSL910, RUGGEDCOM RSL910NC, RUGGEDCOM RST2228, RUGGEDCOM RST2228P, RUGGEDCOM RST916C, RUGGEDCOM RST916P. The third-party component, in its TFTP functionality fails to check for null terminations in file names. If an attacker were to exploit this, it could result in data corruption, and possibly a hard-fault of the application.
Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device.
A vulnerability has been identified in RUGGEDCOM i800, RUGGEDCOM i800NC, RUGGEDCOM i801, RUGGEDCOM i801NC, RUGGEDCOM i802, RUGGEDCOM i802NC, RUGGEDCOM i803, RUGGEDCOM i803NC, RUGGEDCOM M2100, RUGGEDCOM M2100F, RUGGEDCOM M2100NC, RUGGEDCOM M2200, RUGGEDCOM M2200F, RUGGEDCOM M2200NC, RUGGEDCOM M969, RUGGEDCOM M969F, RUGGEDCOM M969NC, RUGGEDCOM RMC30, RUGGEDCOM RMC30NC, RUGGEDCOM RMC8388 V4.X, RUGGEDCOM RMC8388 V5.X, RUGGEDCOM RMC8388NC V4.X, RUGGEDCOM RMC8388NC V5.X, RUGGEDCOM RP110, RUGGEDCOM RP110NC, RUGGEDCOM RS1600, RUGGEDCOM RS1600F, RUGGEDCOM RS1600FNC, RUGGEDCOM RS1600NC, RUGGEDCOM RS1600T, RUGGEDCOM RS1600TNC, RUGGEDCOM RS400, RUGGEDCOM RS400F, RUGGEDCOM RS400NC, RUGGEDCOM RS401, RUGGEDCOM RS401NC, RUGGEDCOM RS416, RUGGEDCOM RS416F, RUGGEDCOM RS416NC, RUGGEDCOM RS416NCv2 V4.X, RUGGEDCOM RS416NCv2 V5.X, RUGGEDCOM RS416P, RUGGEDCOM RS416PF, RUGGEDCOM RS416PNC, RUGGEDCOM RS416PNCv2 V4.X, RUGGEDCOM RS416PNCv2 V5.X, RUGGEDCOM RS416Pv2 V4.X, RUGGEDCOM RS416Pv2 V5.X, RUGGEDCOM RS416v2 V4.X, RUGGEDCOM RS416v2 V5.X, RUGGEDCOM RS8000, RUGGEDCOM RS8000A, RUGGEDCOM RS8000ANC, RUGGEDCOM RS8000H, RUGGEDCOM RS8000HNC, RUGGEDCOM RS8000NC, RUGGEDCOM RS8000T, RUGGEDCOM RS8000TNC, RUGGEDCOM RS900, RUGGEDCOM RS900 (32M) V4.X, RUGGEDCOM RS900 (32M) V5.X, RUGGEDCOM RS900F, RUGGEDCOM RS900G, RUGGEDCOM RS900G (32M) V4.X, RUGGEDCOM RS900G (32M) V5.X, RUGGEDCOM RS900GF, RUGGEDCOM RS900GNC, RUGGEDCOM RS900GNC(32M) V4.X, RUGGEDCOM RS900GNC(32M) V5.X, RUGGEDCOM RS900GP, RUGGEDCOM RS900GPF, RUGGEDCOM RS900GPNC, RUGGEDCOM RS900L, RUGGEDCOM RS900LNC, RUGGEDCOM RS900M-GETS-C01, RUGGEDCOM RS900M-GETS-XX, RUGGEDCOM RS900M-STND-C01, RUGGEDCOM RS900M-STND-XX, RUGGEDCOM RS900MNC-GETS-C01, RUGGEDCOM RS900MNC-GETS-XX, RUGGEDCOM RS900MNC-STND-XX, RUGGEDCOM RS900MNC-STND-XX-C01, RUGGEDCOM RS900NC, RUGGEDCOM RS900NC(32M) V4.X, RUGGEDCOM RS900NC(32M) V5.X, RUGGEDCOM RS900W, RUGGEDCOM RS910, RUGGEDCOM RS910L, RUGGEDCOM RS910LNC, RUGGEDCOM RS910NC, RUGGEDCOM RS910W, RUGGEDCOM RS920L, RUGGEDCOM RS920LNC, RUGGEDCOM RS920W, RUGGEDCOM RS930L, RUGGEDCOM RS930LNC, RUGGEDCOM RS930W, RUGGEDCOM RS940G, RUGGEDCOM RS940GF, RUGGEDCOM RS940GNC, RUGGEDCOM RS969, RUGGEDCOM RS969NC, RUGGEDCOM RSG2100, RUGGEDCOM RSG2100 (32M) V4.X, RUGGEDCOM RSG2100 (32M) V5.X, RUGGEDCOM RSG2100F, RUGGEDCOM RSG2100NC, RUGGEDCOM RSG2100NC(32M) V4.X, RUGGEDCOM RSG2100NC(32M) V5.X, RUGGEDCOM RSG2100P, RUGGEDCOM RSG2100P (32M) V4.X, RUGGEDCOM RSG2100P (32M) V5.X, RUGGEDCOM RSG2100PF, RUGGEDCOM RSG2100PNC, RUGGEDCOM RSG2100PNC (32M) V4.X, RUGGEDCOM RSG2100PNC (32M) V5.X, RUGGEDCOM RSG2200, RUGGEDCOM RSG2200F, RUGGEDCOM RSG2200NC, RUGGEDCOM RSG2288 V4.X, RUGGEDCOM RSG2288 V5.X, RUGGEDCOM RSG2288NC V4.X, RUGGEDCOM RSG2288NC V5.X, RUGGEDCOM RSG2300 V4.X, RUGGEDCOM RSG2300 V5.X, RUGGEDCOM RSG2300F, RUGGEDCOM RSG2300NC V4.X, RUGGEDCOM RSG2300NC V5.X, RUGGEDCOM RSG2300P V4.X, RUGGEDCOM RSG2300P V5.X, RUGGEDCOM RSG2300PF, RUGGEDCOM RSG2300PNC V4.X, RUGGEDCOM RSG2300PNC V5.X, RUGGEDCOM RSG2488 V4.X, RUGGEDCOM RSG2488 V5.X, RUGGEDCOM RSG2488F, RUGGEDCOM RSG2488NC V4.X, RUGGEDCOM RSG2488NC V5.X, RUGGEDCOM RSG907R, RUGGEDCOM RSG908C, RUGGEDCOM RSG909R, RUGGEDCOM RSG910C, RUGGEDCOM RSG920P V4.X, RUGGEDCOM RSG920P V5.X, RUGGEDCOM RSG920PNC V4.X, RUGGEDCOM RSG920PNC V5.X, RUGGEDCOM RSL910, RUGGEDCOM RSL910NC, RUGGEDCOM RST2228, RUGGEDCOM RST2228P, RUGGEDCOM RST916C, RUGGEDCOM RST916P. The web server of the affected devices contains a vulnerability that may lead to a denial of service condition. An attacker may cause total loss of availability of the web server, which might recover after the attack is over.
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543-1 (6GK7543-1AX00-0XE0) (All versions < V3.0.37), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SINAMICS S210 (6SL5...) (All versions >= V6.1 < V6.1 HF2), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1543-1 (6AG1543-1AX00-2XE0) (All versions < V3.0.37). The webserver implementation of the affected products does not correctly release allocated memory after it has been used. An attacker with network access could use this vulnerability to cause a denial-of-service condition in the webserver of the affected product.
A vulnerability has been identified in SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations.
A vulnerability has been identified in SCALANCE XM408-4C (All versions < V6.5), SCALANCE XM408-4C (L3 int.) (All versions < V6.5), SCALANCE XM408-8C (All versions < V6.5), SCALANCE XM408-8C (L3 int.) (All versions < V6.5), SCALANCE XM416-4C (All versions < V6.5), SCALANCE XM416-4C (L3 int.) (All versions < V6.5), SCALANCE XR524-8C, 1x230V (All versions < V6.5), SCALANCE XR524-8C, 1x230V (L3 int.) (All versions < V6.5), SCALANCE XR524-8C, 24V (All versions < V6.5), SCALANCE XR524-8C, 24V (L3 int.) (All versions < V6.5), SCALANCE XR524-8C, 2x230V (All versions < V6.5), SCALANCE XR524-8C, 2x230V (L3 int.) (All versions < V6.5), SCALANCE XR526-8C, 1x230V (All versions < V6.5), SCALANCE XR526-8C, 1x230V (L3 int.) (All versions < V6.5), SCALANCE XR526-8C, 24V (All versions < V6.5), SCALANCE XR526-8C, 24V (L3 int.) (All versions < V6.5), SCALANCE XR526-8C, 2x230V (All versions < V6.5), SCALANCE XR526-8C, 2x230V (L3 int.) (All versions < V6.5), SCALANCE XR528-6M (All versions < V6.5), SCALANCE XR528-6M (2HR2) (All versions < V6.5), SCALANCE XR528-6M (2HR2, L3 int.) (All versions < V6.5), SCALANCE XR528-6M (L3 int.) (All versions < V6.5), SCALANCE XR552-12M (All versions < V6.5), SCALANCE XR552-12M (2HR2) (All versions < V6.5), SCALANCE XR552-12M (2HR2) (All versions < V6.5), SCALANCE XR552-12M (2HR2, L3 int.) (All versions < V6.5). The OSPF protocol implementation in affected devices fails to verify the checksum and length fields in the OSPF LS Update messages. An unauthenticated remote attacker could exploit this vulnerability to cause interruptions in the network by sending specially crafted OSPF packets. Successful exploitation requires OSPF to be enabled on an affected device.
A vulnerability has been identified in SINUMERIK 808D (All versions), SINUMERIK 828D (All versions < V4.95). Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial-of-service in the device.
A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 Ready4Linux (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packet over port 102/tcp. A restart of the affected device is needed to restore normal operations.
axios is vulnerable to Inefficient Regular Expression Complexity
A vulnerability has been identified in SIPROTEC 5 relays with CPU variants CP050 (All versions < V8.80), SIPROTEC 5 relays with CPU variants CP100 (All versions < V8.80), SIPROTEC 5 relays with CPU variants CP300 (All versions < V8.80). Received webpackets are not properly processed. An unauthenticated remote attacker with access to any of the Ethernet interfaces could send specially crafted packets to force a restart of the target device.
A vulnerability has been identified in SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations.
A vulnerability has been identified in SIMATIC MV540 H (All versions < V3.3.4), SIMATIC MV540 S (All versions < V3.3.4), SIMATIC MV550 H (All versions < V3.3.4), SIMATIC MV550 S (All versions < V3.3.4), SIMATIC MV560 U (All versions < V3.3.4), SIMATIC MV560 X (All versions < V3.3.4). Affected devices cannot properly process specially crafted Ethernet frames sent to the devices. This could allow an unauthenticated remote attacker to cause a denial of service condition. The affected devices must be restarted manually.
Malformed requests may cause the server to dereference a NULL pointer. This issue affects Apache HTTP Server 2.4.48 and earlier.
A vulnerability has been identified in SIMATIC MV540 H (All versions < V3.3.4), SIMATIC MV540 S (All versions < V3.3.4), SIMATIC MV550 H (All versions < V3.3.4), SIMATIC MV550 S (All versions < V3.3.4), SIMATIC MV560 U (All versions < V3.3.4), SIMATIC MV560 X (All versions < V3.3.4). Affected devices cannot properly process specially crafted IP packets sent to the devices. This could allow an unauthenticated remote attacker to cause a denial of service condition. The affected devices must be restarted manually.
A vulnerability has been identified in SIPROTEC 5 relays with CPU variants CP050 (All versions < V8.80), SIPROTEC 5 relays with CPU variants CP100 (All versions < V8.80), SIPROTEC 5 relays with CPU variants CP300 (All versions < V8.80). Specially crafted packets sent to port 4443/tcp could cause a Denial-of-Service condition.
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0). Malformed TCP packets with a corrupted SACK option leads to Information Leaks and Denial-of-Service conditions. (FSMD-2021-0015)
A vulnerability has been identified in SIMATIC RF166C (All versions > V1.1 and < V1.3.2), SIMATIC RF185C (All versions > V1.1 and < V1.3.2), SIMATIC RF186C (All versions > V1.1 and < V1.3.2), SIMATIC RF186CI (All versions > V1.1 and < V1.3.2), SIMATIC RF188C (All versions > V1.1 and < V1.3.2), SIMATIC RF188CI (All versions > V1.1 and < V1.3.2), SIMATIC RF360R (All versions < V2.0), SIMATIC Reader RF610R CMIIT (All versions > V3.0 < V4.0), SIMATIC Reader RF610R ETSI (All versions > V3.0 < V4.0), SIMATIC Reader RF610R FCC (All versions > V3.0 < V4.0), SIMATIC Reader RF615R CMIIT (All versions > V3.0 < V4.0), SIMATIC Reader RF615R ETSI (All versions > V3.0 < V4.0), SIMATIC Reader RF615R FCC (All versions > V3.0 < V4.0), SIMATIC Reader RF650R ARIB (All versions > V3.0 < V4.0), SIMATIC Reader RF650R CMIIT (All versions > V3.0 < V4.0), SIMATIC Reader RF650R ETSI (All versions > V3.0 < V4.0), SIMATIC Reader RF650R FCC (All versions > V3.0 < V4.0), SIMATIC Reader RF680R ARIB (All versions > V3.0 < V4.0), SIMATIC Reader RF680R CMIIT (All versions > V3.0 < V4.0), SIMATIC Reader RF680R ETSI (All versions > V3.0 < V4.0), SIMATIC Reader RF680R FCC (All versions > V3.0 < V4.0), SIMATIC Reader RF685R ARIB (All versions > V3.0 < V4.0), SIMATIC Reader RF685R CMIIT (All versions > V3.0 < V4.0), SIMATIC Reader RF685R ETSI (All versions > V3.0 < V4.0), SIMATIC Reader RF685R FCC (All versions > V3.0 < V4.0). Affected devices do not properly handle large numbers of incoming connections. An attacker may leverage this to cause a Denial-of-Service situation.
sqlite3Select in select.c in SQLite 3.30.1 allows a crash if a sub-select uses both DISTINCT and window functions, and also has certain ORDER BY usage.
A vulnerability has been identified in SCALANCE X200-4P IRT, SCALANCE X201-3P IRT, SCALANCE X201-3P IRT PRO, SCALANCE X202-2IRT, SCALANCE X202-2P IRT, SCALANCE X202-2P IRT PRO, SCALANCE X204-2, SCALANCE X204-2FM, SCALANCE X204-2LD, SCALANCE X204-2LD TS, SCALANCE X204-2TS, SCALANCE X204IRT, SCALANCE X204IRT PRO, SCALANCE X206-1, SCALANCE X206-1LD, SCALANCE X208, SCALANCE X208PRO, SCALANCE X212-2, SCALANCE X212-2LD, SCALANCE X216, SCALANCE X224, SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XF201-3P IRT, SCALANCE XF202-2P IRT, SCALANCE XF204, SCALANCE XF204-2, SCALANCE XF204-2BA IRT, SCALANCE XF204IRT, SCALANCE XF206-1, SCALANCE XF208, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIMATIC CP 343-1 Advanced, SIMATIC CP 442-1 RNA, SIMATIC CP 443-1, SIMATIC CP 443-1, SIMATIC CP 443-1 Advanced, SIMATIC CP 443-1 RNA, SIMATIC RF180C, SIMATIC RF182C, SIPLUS NET CP 343-1 Advanced, SIPLUS NET CP 443-1, SIPLUS NET CP 443-1 Advanced, SIPLUS NET SCALANCE X308-2. The VxWorks-based Profinet TCP Stack can be forced to make very expensive calls for every incoming packet which can lead to a denial of service.