Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2019-6584

Summary
Assigner-siemens
Assigner Org ID-cec7a2ec-15b4-4faf-bd53-b40f371f3a77
Published At-12 Jun, 2019 | 13:47
Updated At-04 Aug, 2024 | 20:23
Rejected At-
Credits

A vulnerability has been identified in SIEMENS LOGO!8 (6ED1052-xyyxx-0BA8 FS:01 to FS:06 / Firmware version V1.80.xx and V1.81.xx), SIEMENS LOGO!8 (6ED1052-xyy08-0BA0 FS:01 / Firmware version < V1.82.02). The integrated webserver does not invalidate the Session ID upon user logout. An attacker that successfully extracted a valid Session ID is able to use it even after the user logs out. The security vulnerability could be exploited by an attacker in a privileged network position who is able to read the communication between the affected device and the user or by an attacker who is able to obtain valid Session IDs through other means. The user must invoke a session to the affected device. At the time of advisory publication no public exploitation of this security vulnerability was known.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:siemens
Assigner Org ID:cec7a2ec-15b4-4faf-bd53-b40f371f3a77
Published At:12 Jun, 2019 | 13:47
Updated At:04 Aug, 2024 | 20:23
Rejected At:
▼CVE Numbering Authority (CNA)

A vulnerability has been identified in SIEMENS LOGO!8 (6ED1052-xyyxx-0BA8 FS:01 to FS:06 / Firmware version V1.80.xx and V1.81.xx), SIEMENS LOGO!8 (6ED1052-xyy08-0BA0 FS:01 / Firmware version < V1.82.02). The integrated webserver does not invalidate the Session ID upon user logout. An attacker that successfully extracted a valid Session ID is able to use it even after the user logs out. The security vulnerability could be exploited by an attacker in a privileged network position who is able to read the communication between the affected device and the user or by an attacker who is able to obtain valid Session IDs through other means. The user must invoke a session to the affected device. At the time of advisory publication no public exploitation of this security vulnerability was known.

Affected Products
Vendor
Siemens AGSiemens AG
Product
SIEMENS LOGO!8
Versions
Affected
  • 6ED1052-xyyxx-0BA8 FS:01 to FS:06 / Firmware version V1.80.xx and V1.81.xx
Vendor
Siemens AGSiemens AG
Product
SIEMENS LOGO!8
Versions
Affected
  • 6ED1052-xyy08-0BA0 FS:01 / Firmware version < V1.82.02
Problem Types
TypeCWE IDDescription
CWECWE-384CWE-384: Session Fixation
Type: CWE
CWE ID: CWE-384
Description: CWE-384: Session Fixation
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://cert-portal.siemens.com/productcert/pdf/ssa-774850.pdf
x_refsource_MISC
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-774850.pdf
Resource:
x_refsource_MISC
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://cert-portal.siemens.com/productcert/pdf/ssa-774850.pdf
x_refsource_MISC
x_transferred
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-774850.pdf
Resource:
x_refsource_MISC
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:productcert@siemens.com
Published At:12 Jun, 2019 | 14:29
Updated At:29 Sep, 2020 | 00:30

A vulnerability has been identified in SIEMENS LOGO!8 (6ED1052-xyyxx-0BA8 FS:01 to FS:06 / Firmware version V1.80.xx and V1.81.xx), SIEMENS LOGO!8 (6ED1052-xyy08-0BA0 FS:01 / Firmware version < V1.82.02). The integrated webserver does not invalidate the Session ID upon user logout. An attacker that successfully extracted a valid Session ID is able to use it even after the user logs out. The security vulnerability could be exploited by an attacker in a privileged network position who is able to read the communication between the affected device and the user or by an attacker who is able to obtain valid Session IDs through other means. The user must invoke a session to the affected device. At the time of advisory publication no public exploitation of this security vulnerability was known.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Primary2.06.8MEDIUM
AV:N/AC:M/Au:N/C:P/I:P/A:P
Type: Primary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Type: Primary
Version: 2.0
Base score: 6.8
Base severity: MEDIUM
Vector:
AV:N/AC:M/Au:N/C:P/I:P/A:P
CPE Matches

Siemens AG
siemens
>>logo\!8_firmware>>Versions from 1.80.00(inclusive) to 1.81.00(inclusive)
cpe:2.3:o:siemens:logo\!8_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>logo\!8>>-
cpe:2.3:h:siemens:logo\!8:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>logo\!8_firmware>>Versions before 1.82.00(exclusive)
cpe:2.3:o:siemens:logo\!8_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>logo\!8>>-
cpe:2.3:h:siemens:logo\!8:-:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-613Primarynvd@nist.gov
CWE-384Secondaryproductcert@siemens.com
CWE ID: CWE-613
Type: Primary
Source: nvd@nist.gov
CWE ID: CWE-384
Type: Secondary
Source: productcert@siemens.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://cert-portal.siemens.com/productcert/pdf/ssa-774850.pdfproductcert@siemens.com
Patch
Vendor Advisory
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-774850.pdf
Source: productcert@siemens.com
Resource:
Patch
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

299Records found

CVE-2021-44016
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.31% / 53.36%
||
7 Day CHG~0.00%
Published-09 Feb, 2022 | 15:17
Updated-04 Aug, 2024 | 04:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V13.2.0.7), Solid Edge SE2021 (All versions < SE2021MP9), Solid Edge SE2022 (All versions < SE2022MP1), Teamcenter Visualization V13.1 (All versions < V13.1.0.9), Teamcenter Visualization V13.2 (All versions < V13.2.0.7), Teamcenter Visualization V13.3 (All versions < V13.3.0.1). The plmxmlAdapterSE70.dll library is vulnerable to memory corruption condition while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-15110)

Action-Not Available
Vendor-Siemens AG
Product-jt2gosolid_edgeteamcenter_visualizationSolid Edge SE2021Teamcenter Visualization V13.2Teamcenter Visualization V13.3JT2GoTeamcenter Visualization V13.1Solid Edge SE2022
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-787
Out-of-bounds Write
CVE-2020-26994
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-1.59% / 80.93%
||
7 Day CHG~0.00%
Published-12 Jan, 2021 | 20:18
Updated-04 Aug, 2024 | 16:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V13.1.0), Teamcenter Visualization (All versions < V13.1.0). Affected applications lack proper validation of user-supplied data when parsing of PCX files. This could result in a heap-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-jt2goteamcenter_visualizationJT2GoTeamcenter Visualization
CWE ID-CWE-122
Heap-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-46098
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8||HIGH
EPSS-0.19% / 40.83%
||
7 Day CHG~0.00%
Published-14 Nov, 2023 | 11:04
Updated-08 Jan, 2025 | 16:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC PCS neo (All versions < V4.1). When accessing the Information Server from affected products, the products use an overly permissive CORS policy. This could allow an attacker to trick a legitimate user to trigger unwanted behavior.

Action-Not Available
Vendor-Siemens AG
Product-simatic_pcs_neoSIMATIC PCS neo
CWE ID-CWE-942
Permissive Cross-domain Policy with Untrusted Domains
CVE-2021-41535
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.59% / 68.22%
||
7 Day CHG~0.00%
Published-28 Sep, 2021 | 11:12
Updated-04 Aug, 2024 | 03:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in NX 1953 Series (All versions < V1973.3700), NX 1980 Series (All versions < V1988), Solid Edge SE2021 (All versions < SE2021MP8). The affected application contains a use-after-free vulnerability while parsing OBJ files. An attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13771).

Action-Not Available
Vendor-Siemens AG
Product-nx_1969nx_1965nx_1961_firmwarenx_1988_firmwarenx_1984nx_1969_firmwarenx_1961nx_1984_firmwarenx_1957nx_1965_firmwarenx_1988nx_1957_firmwaresolid_edgeNX 1980 SeriesNX 1953 SeriesSolid Edge SE2021
CWE ID-CWE-416
Use After Free
CVE-2021-41539
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.68% / 70.60%
||
7 Day CHG~0.00%
Published-28 Sep, 2021 | 11:12
Updated-04 Aug, 2024 | 03:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Solid Edge SE2021 (All versions < SE2021MP8). The affected application contains a use-after-free vulnerability while parsing OBJ files. An attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13773).

Action-Not Available
Vendor-Siemens AG
Product-solid_edgeSolid Edge SE2021
CWE ID-CWE-416
Use After Free
CVE-2020-15795
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.1||HIGH
EPSS-0.69% / 70.77%
||
7 Day CHG~0.00%
Published-22 Apr, 2021 | 20:42
Updated-04 Aug, 2024 | 13:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions < V5.2), Nucleus Source Code (Versions including affected DNS modules), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS domain name label parsing functionality does not properly validate the names in DNS-responses. The parsing of malformed responses could result in a write past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to execute code in the context of the current process or cause a denial-of-service condition.

Action-Not Available
Vendor-Siemens AG
Product-nucleus_netnucleus_source_codeTALON TC Compact (BACnet)APOGEE PXC Compact (P2 Ethernet)Nucleus Source CodeAPOGEE PXC Compact (BACnet)APOGEE PXC Modular (P2 Ethernet)Nucleus NETAPOGEE PXC Modular (BACnet)TALON TC Modular (BACnet)
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-46161
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.40% / 60.18%
||
7 Day CHG~0.00%
Published-09 Feb, 2022 | 15:17
Updated-04 Aug, 2024 | 05:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15302)

Action-Not Available
Vendor-Siemens AG
Product-simcenter_femapSimcenter Femap V2020.2Simcenter Femap V2021.1
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-41540
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.68% / 70.60%
||
7 Day CHG~0.00%
Published-28 Sep, 2021 | 11:12
Updated-04 Aug, 2024 | 03:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Solid Edge SE2021 (All versions < SE2021MP8). The affected application contains a use-after-free vulnerability while parsing OBJ files. An attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13776).

Action-Not Available
Vendor-Siemens AG
Product-solid_edgeSolid Edge SE2021
CWE ID-CWE-416
Use After Free
CVE-2021-44014
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.69% / 70.79%
||
7 Day CHG~0.00%
Published-14 Dec, 2021 | 12:06
Updated-04 Aug, 2024 | 04:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT Open (All versions < V11.1.1.0), JT Utilities (All versions < V13.1.1.0), Solid Edge (All versions < V2023). The Jt1001.dll contains a use-after-free vulnerability that could be triggered while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-15057, ZDI-CAN-19081)

Action-Not Available
Vendor-Siemens AG
Product-jt2gojt_open_toolkitteamcenter_visualizationjt_utilitiessolid_edgeJT OpenSolid EdgeJT Utilities
CWE ID-CWE-416
Use After Free
CVE-2021-44000
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.29% / 51.87%
||
7 Day CHG~0.00%
Published-09 Feb, 2022 | 15:17
Updated-04 Aug, 2024 | 04:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V13.2.0.7), Solid Edge SE2021 (All versions < SE2021MP9), Solid Edge SE2022 (All versions < SE2022MP1), Teamcenter Visualization V13.1 (All versions < V13.1.0.9), Teamcenter Visualization V13.2 (All versions < V13.2.0.7), Teamcenter Visualization V13.3 (All versions < V13.3.0.1). The plmxmlAdapterSE70.dll contains an out of bounds write past the fixed-length heap-based buffer while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15053)

Action-Not Available
Vendor-Siemens AG
Product-jt2gosolid_edgeteamcenter_visualizationSolid Edge SE2021Teamcenter Visualization V13.2Teamcenter Visualization V13.3JT2GoTeamcenter Visualization V13.1Solid Edge SE2022
CWE ID-CWE-122
Heap-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-44437
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.42% / 60.99%
||
7 Day CHG~0.00%
Published-14 Dec, 2021 | 12:06
Updated-04 Aug, 2024 | 04:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT Utilities (All versions < V13.1.1.0), JTTK (All versions < V11.1.1.0). JTTK library in affected products is vulnerable to an out of bounds write past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14906)

Action-Not Available
Vendor-Siemens AG
Product-jt_utilitiesjt_open_toolkitJTTKJT Utilities
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-44433
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.68% / 70.60%
||
7 Day CHG~0.00%
Published-14 Dec, 2021 | 12:06
Updated-04 Aug, 2024 | 04:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT Utilities (All versions < V13.1.1.0), JTTK (All versions < V11.1.1.0). JTTK library in affected products contains a use after free vulnerability that could be triggered while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-14900)

Action-Not Available
Vendor-Siemens AG
Product-jt_utilitiesjt_open_toolkitJTTKJT Utilities
CWE ID-CWE-416
Use After Free
CVE-2021-44446
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.42% / 60.99%
||
7 Day CHG~0.00%
Published-14 Dec, 2021 | 12:07
Updated-04 Aug, 2024 | 04:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT Utilities (All versions < V13.0.3.0), JTTK (All versions < V11.0.3.0). JTTK library in affected products contains an out of bounds write past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14828, ZDI-CAN-14898)

Action-Not Available
Vendor-Siemens AG
Product-jt_utilitiesjt_open_toolkitJTTKJT Utilities
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-44450
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.22% / 44.28%
||
7 Day CHG~0.00%
Published-14 Dec, 2021 | 12:07
Updated-04 Aug, 2024 | 04:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT Utilities (All versions < V12.8.1.1), JTTK (All versions < V10.8.1.1). JTTK library in affected products is vulnerable to an out of bounds read past the end of an allocated buffer when parsing JT files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-15055, ZDI-CAN-14915, ZDI-CAN-14865)

Action-Not Available
Vendor-Siemens AG
Product-jt_utilitiesjt_open_toolkitJTTKJT Utilities
CWE ID-CWE-125
Out-of-bounds Read
CVE-2021-44434
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.42% / 60.99%
||
7 Day CHG~0.00%
Published-14 Dec, 2021 | 12:06
Updated-04 Aug, 2024 | 04:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT Utilities (All versions < V13.1.1.0), JTTK (All versions < V11.1.1.0). JTTK library in affected products is vulnerable to an out of bounds write past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14902, ZDI-CAN-14866)

Action-Not Available
Vendor-Siemens AG
Product-jt_utilitiesjt_open_toolkitJTTKJT Utilities
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-41536
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.68% / 70.60%
||
7 Day CHG~0.00%
Published-28 Sep, 2021 | 11:12
Updated-04 Aug, 2024 | 03:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Solid Edge SE2021 (All versions < SE2021MP8). The affected application contains a use-after-free vulnerability while parsing OBJ files. An attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13778).

Action-Not Available
Vendor-Siemens AG
Product-solid_edgeSolid Edge SE2021
CWE ID-CWE-416
Use After Free
CVE-2021-44440
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.37% / 57.91%
||
7 Day CHG~0.00%
Published-14 Dec, 2021 | 12:07
Updated-04 Aug, 2024 | 04:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT Utilities (All versions < V13.1.1.0), JTTK (All versions < V11.1.1.0). JTTK library in affected products is vulnerable to memory corruption condition while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-14912)

Action-Not Available
Vendor-Siemens AG
Product-jt_utilitiesjt_open_toolkitJTTKJT Utilities
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-44430
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.42% / 60.99%
||
7 Day CHG~0.00%
Published-14 Dec, 2021 | 12:06
Updated-04 Aug, 2024 | 04:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT Utilities (All versions < V13.1.1.0), JTTK (All versions < V11.1.1.0). JTTK library in affected products is vulnerable to an out of bounds write past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14829)

Action-Not Available
Vendor-Siemens AG
Product-jt_utilitiesjt_open_toolkitJTTKJT Utilities
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-43336
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-7.8||HIGH
EPSS-0.27% / 49.92%
||
7 Day CHG~0.00%
Published-14 Nov, 2021 | 00:00
Updated-04 Aug, 2024 | 03:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An Out-of-Bounds Write vulnerability exists when reading a DXF or DWG file using Open Design Alliance Drawings SDK before 2022.11. The specific issue exists within the parsing of DXF and DWG files. Crafted data in a DXF or DWG file (an invalid number of properties) can trigger a write operation past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process.

Action-Not Available
Vendor-opendesignn/aSiemens AG
Product-jt2godrawings_software_development_kitsolid_edgeteamcenter_visualizationn/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-41537
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.68% / 70.60%
||
7 Day CHG~0.00%
Published-28 Sep, 2021 | 11:12
Updated-04 Aug, 2024 | 03:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Solid Edge SE2021 (All versions < SE2021MP8). The affected application contains a use-after-free vulnerability while parsing OBJ files. An attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13789).

Action-Not Available
Vendor-Siemens AG
Product-solid_edgeSolid Edge SE2021
CWE ID-CWE-416
Use After Free
CVE-2021-42024
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.42% / 60.99%
||
7 Day CHG~0.00%
Published-14 Dec, 2021 | 12:06
Updated-04 Aug, 2024 | 03:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Simcenter STAR-CCM+ Viewer (All versions < 2021.3.1). The starview+.exe application lacks proper validation of user-supplied data when parsing scene files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-simcenter_star-ccm\+_viewerSimcenter STAR-CCM+ Viewer
CWE ID-CWE-787
Out-of-bounds Write
CVE-2013-0656
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-6.8||MEDIUM
EPSS-2.13% / 83.49%
||
7 Day CHG~0.00%
Published-21 Jan, 2013 | 21:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Buffer overflow in a third-party ActiveX component in Siemens SIMATIC RF-MANAGER 2008, and RF-MANAGER Basic 3.0 and earlier, allows remote attackers to execute arbitrary code via a crafted web site.

Action-Not Available
Vendor-n/aSiemens AG
Product-simatic_rf-manager_2008simatic_rf-managern/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2013-0674
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-6.8||MEDIUM
EPSS-2.71% / 85.33%
||
7 Day CHG~0.00%
Published-21 Mar, 2013 | 15:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Buffer overflow in the RegReader ActiveX control in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to execute arbitrary code via a long parameter.

Action-Not Available
Vendor-n/aSiemens AG
Product-simatic_pcs7winccn/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2020-28382
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.34% / 56.34%
||
7 Day CHG~0.00%
Published-12 Jan, 2021 | 20:18
Updated-04 Aug, 2024 | 16:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Solid Edge SE2020 (All Versions < SE2020MP12), Solid Edge SE2021 (All Versions < SE2021MP2). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in a out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-solid_edgeSolid Edge SE2021Solid Edge SE2020
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-40438
Matching Score-8
Assigner-Apache Software Foundation
ShareView Details
Matching Score-8
Assigner-Apache Software Foundation
CVSS Score-9||CRITICAL
EPSS-94.44% / 99.99%
||
7 Day CHG~0.00%
Published-16 Sep, 2021 | 14:40
Updated-30 Jul, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Known KEV||Action Due Date - 2021-12-15||Apply updates per vendor instructions.
mod_proxy SSRF

A crafted request uri-path can cause mod_proxy to forward the request to an origin server choosen by the remote user. This issue affects Apache HTTP Server 2.4.48 and earlier.

Action-Not Available
Vendor-resfBroadcom Inc.F5, Inc.NetApp, Inc.Siemens AGDebian GNU/LinuxRed Hat, Inc.Tenable, Inc.Fedora ProjectThe Apache Software FoundationOracle Corporation
Product-enterprise_linux_for_power_big_endianenterprise_linux_server_workstationenterprise_linux_workstationsinec_nmsenterprise_linux_server_ausbrocade_fabric_operating_system_firmwaresoftware_collectionsenterprise_linux_update_services_for_sap_solutionsclustered_data_ontapenterprise_linux_serverzfs_storage_appliance_kitsecure_global_desktopenterprise_linux_for_power_little_endiansinema_serverenterprise_linux_for_arm_64storagegridf5osenterprise_linux_server_for_power_little_endian_update_services_for_sap_solutionsenterprise_linux_eusenterprise_linux_server_tusenterprise_linux_server_update_services_for_sap_solutionsenterprise_linuxhttp_serverinstantis_enterprisetrackcloud_backuptenable.scrocky_linuxenterprise_manager_ops_centerruggedcom_nmsenterprise_linux_for_scientific_computingenterprise_linux_for_ibm_z_systemsenterprise_linux_for_power_little_endian_eussinema_remote_connect_serverfedorajboss_core_servicesdebian_linuxenterprise_linux_for_ibm_z_systems_eus_s390xenterprise_linux_for_ibm_z_systems_eusenterprise_linux_for_arm_64_eusApache HTTP ServerApache
CWE ID-CWE-918
Server-Side Request Forgery (SSRF)
CVE-2022-25754
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.23% / 46.10%
||
7 Day CHG~0.00%
Published-12 Apr, 2022 | 09:07
Updated-03 Aug, 2024 | 04:49
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The integrated web server of the affected device could allow remote attackers to perform actions with the permissions of a victim user, provided the victim user has an active session and is induced to trigger the malicious request.

Action-Not Available
Vendor-Siemens AG
Product-scalance_x308-2m_ts_firmwarescalance_x307-3_firmwarescalance_xr324-12mscalance_x310fescalance_x310fe_firmwarescalance_xr324-4m_eecscalance_x308-2ldscalance_x320-1fe_firmwaresiplus_net_scalance_x308-2scalance_xr324-4m_poe_firmwarescalance_x308-2scalance_x307-2eecscalance_xr324-4m_eec_firmwarescalance_x308-2_firmwarescalance_x304-2fe_firmwarescalance_xr324-12m_ts_firmwarescalance_x306-1ldfe_firmwarescalance_x307-2eec_firmwarescalance_x320-1-2ldfesiplus_net_scalance_x308-2_firmwarescalance_x308-2lh_firmwarescalance_x302-7eec_firmwarescalance_x308-2lhscalance_x307-3ld_firmwarescalance_x310scalance_x320-1-2ldfe_firmwarescalance_xr324-12m_firmwarescalance_x308-2m_poe_firmwarescalance_x308-2lh\+scalance_x310_firmwarescalance_x308-2m_poescalance_x308-2lh\+_firmwarescalance_x308-2ld_firmwarescalance_xr324-12m_tsscalance_x308-2m_tsscalance_x308-2m_firmwarescalance_x320-1fescalance_x408-2scalance_xr324-4m_poescalance_x306-1ldfescalance_x307-3ldscalance_x308-2mscalance_x408-2_firmwarescalance_x307-3scalance_x304-2fescalance_xr324-4m_poe_tsscalance_xr324-4m_poe_ts_firmwarescalance_x302-7eecSCALANCE XR324-12M TS (24V)SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)SCALANCE XR324-4M PoE (24V, ports on rear)SCALANCE XR324-4M EEC (24V, ports on front)SCALANCE XR324-12M (230V, ports on rear)SCALANCE X307-2 EEC (2x 24V, coated)SCALANCE XR324-4M PoE TS (24V, ports on front)SCALANCE X307-3SCALANCE X308-2MSCALANCE XR324-12M (24V, ports on rear)SCALANCE X308-2SCALANCE X308-2M PoESCALANCE X310FESCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)SCALANCE X308-2LH+SCALANCE X302-7 EEC (24V, coated)SCALANCE X307-2 EEC (230V, coated)SCALANCE X307-3LDSCALANCE X308-2LHSCALANCE XR324-4M EEC (24V, ports on rear)SCALANCE XR324-4M PoE (24V, ports on front)SCALANCE X302-7 EEC (2x 230V)SCALANCE X408-2SIPLUS NET SCALANCE X308-2SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)SCALANCE XR324-4M PoE (230V, ports on rear)SCALANCE X302-7 EEC (230V)SCALANCE X307-2 EEC (24V, coated)SCALANCE X307-2 EEC (2x 230V, coated)SCALANCE X302-7 EEC (2x 24V, coated)SCALANCE X308-2LDSCALANCE X307-2 EEC (24V)SCALANCE X304-2FESCALANCE X310SCALANCE X307-2 EEC (2x 24V)SCALANCE X307-2 EEC (230V)SCALANCE XR324-12M (24V, ports on front)SCALANCE X320-1 FESCALANCE X302-7 EEC (2x 24V)SCALANCE X306-1LD FESCALANCE X308-2M TSSCALANCE XR324-4M PoE (230V, ports on front)SCALANCE X307-2 EEC (2x 230V)SCALANCE X302-7 EEC (24V)SCALANCE X302-7 EEC (230V, coated)SCALANCE X302-7 EEC (2x 230V, coated)SCALANCE X320-1-2LD FESCALANCE XR324-4M EEC (2x 24V, ports on rear)SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)SCALANCE XR324-12M (230V, ports on front)SCALANCE XR324-4M EEC (2x 24V, ports on front)
CWE ID-CWE-352
Cross-Site Request Forgery (CSRF)
CVE-2020-27009
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.1||HIGH
EPSS-0.69% / 70.85%
||
7 Day CHG~0.00%
Published-22 Apr, 2021 | 20:42
Updated-04 Aug, 2024 | 16:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions < V5.2), Nucleus Source Code (Versions including affected DNS modules), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS domain name record decompression functionality does not properly validate the pointer offset values. The parsing of malformed responses could result in a write past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to execute code in the context of the current process or cause a denial-of-service condition.

Action-Not Available
Vendor-Siemens AG
Product-nucleus_netnucleus_source_codeTALON TC Compact (BACnet)APOGEE PXC Compact (P2 Ethernet)Nucleus Source CodeAPOGEE PXC Compact (BACnet)APOGEE PXC Modular (P2 Ethernet)Nucleus NETAPOGEE PXC Modular (BACnet)TALON TC Modular (BACnet)
CWE ID-CWE-823
Use of Out-of-range Pointer Offset
CWE ID-CWE-787
Out-of-bounds Write
CVE-2020-26984
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-1.07% / 76.87%
||
7 Day CHG~0.00%
Published-12 Jan, 2021 | 20:18
Updated-04 Aug, 2024 | 16:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V13.1.0), Teamcenter Visualization (All versions < V13.1.0). Affected applications lack proper validation of user-supplied data when parsing of JT files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11972)

Action-Not Available
Vendor-Siemens AG
Product-jt2goteamcenter_visualizationJT2GoTeamcenter Visualization
CWE ID-CWE-787
Out-of-bounds Write
CVE-2012-3028
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-6.8||MEDIUM
EPSS-0.17% / 38.62%
||
7 Day CHG~0.00%
Published-18 Sep, 2012 | 14:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Cross-site request forgery (CSRF) vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to hijack the authentication of arbitrary users for requests that modify data or cause a denial of service.

Action-Not Available
Vendor-n/aSiemens AG
Product-winccsimatic_pcs7n/a
CWE ID-CWE-352
Cross-Site Request Forgery (CSRF)
CVE-2020-26987
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-4.10% / 88.14%
||
7 Day CHG~0.00%
Published-12 Jan, 2021 | 20:18
Updated-04 Aug, 2024 | 16:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V13.1.0), Teamcenter Visualization (All versions < V13.1.0). Affected applications lack proper validation of user-supplied data when parsing of TGA files. This could lead to a heap-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12016, ZDI-CAN-12017)

Action-Not Available
Vendor-Siemens AG
Product-jt2goteamcenter_visualizationJT2GoTeamcenter Visualization
CWE ID-CWE-122
Heap-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2020-26985
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-4.10% / 88.14%
||
7 Day CHG~0.00%
Published-12 Jan, 2021 | 20:18
Updated-04 Aug, 2024 | 16:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V13.1.0), Teamcenter Visualization (All versions < V13.1.0). Affected applications lack proper validation of user-supplied data when parsing of RGB and SGI files. This could result in a heap-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11986, ZDI-CAN-11994)

Action-Not Available
Vendor-Siemens AG
Product-jt2goteamcenter_visualizationJT2GoTeamcenter Visualization
CWE ID-CWE-122
Heap-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-36386
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.47% / 63.52%
||
7 Day CHG~0.00%
Published-11 Jul, 2023 | 09:07
Updated-21 Oct, 2024 | 21:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected application that could allow an attacker to execute malicious javascript code by tricking users into accessing a malicious link. The value is reflected in the response without sanitization while throwing an “invalid params element name” error on the get_elements parameters.

Action-Not Available
Vendor-Siemens AG
Product-ruggedcom_rox_mx5000reruggedcom_rox_rx1511ruggedcom_rox_rx1512_firmwareruggedcom_rox_rx1512ruggedcom_rox_mx5000_firmwareruggedcom_rox_rx1511_firmwareruggedcom_rox_rx1510ruggedcom_rox_rx1400_firmwareruggedcom_rox_rx1500_firmwareruggedcom_rox_rx1400ruggedcom_rox_rx1510_firmwareruggedcom_rox_rx1500ruggedcom_rox_rx1524_firmwareruggedcom_rox_rx5000ruggedcom_rox_rx1501ruggedcom_rox_rx1536ruggedcom_rox_mx5000ruggedcom_rox_rx1524ruggedcom_rox_rx1536_firmwareruggedcom_rox_mx5000re_firmwareruggedcom_rox_rx1501_firmwareruggedcom_rox_rx5000_firmwareRUGGEDCOM ROX MX5000RERUGGEDCOM ROX RX1511RUGGEDCOM ROX RX1536RUGGEDCOM ROX RX1400RUGGEDCOM ROX RX1501RUGGEDCOM ROX RX1500RUGGEDCOM ROX RX5000RUGGEDCOM ROX MX5000RUGGEDCOM ROX RX1524RUGGEDCOM ROX RX1510RUGGEDCOM ROX RX1512
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2023-36390
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.47% / 63.52%
||
7 Day CHG~0.00%
Published-11 Jul, 2023 | 09:07
Updated-01 Aug, 2025 | 02:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected application that could allow an attacker to execute malicious javascript code by tricking users into accessing a malicious link. The value is reflected in the response without sanitization while throwing an “invalid params element name” error on the action parameters.

Action-Not Available
Vendor-Siemens AG
Product-ruggedcom_rox_rx1400_firmwareruggedcom_rox_mx5000reruggedcom_rox_rx1536_firmwareruggedcom_rox_rx5000_firmwareruggedcom_rox_mx5000ruggedcom_rox_rx1500ruggedcom_rox_rx1536ruggedcom_rox_rx1512_firmwareruggedcom_rox_mx5000_firmwareruggedcom_rox_rx1501ruggedcom_rox_rx1501_firmwareruggedcom_rox_rx1500_firmwareruggedcom_rox_rx5000ruggedcom_rox_rx1524_firmwareruggedcom_rox_rx1512ruggedcom_rox_rx1524ruggedcom_rox_rx1511ruggedcom_rox_mx5000re_firmwareruggedcom_rox_rx1510ruggedcom_rox_rx1511_firmwareruggedcom_rox_rx1400ruggedcom_rox_rx1510_firmwareRUGGEDCOM ROX MX5000RERUGGEDCOM ROX RX1511RUGGEDCOM ROX RX1536RUGGEDCOM ROX RX1400RUGGEDCOM ROX RX1501RUGGEDCOM ROX RX1500RUGGEDCOM ROX RX5000RUGGEDCOM ROX MX5000RUGGEDCOM ROX RX1524RUGGEDCOM ROX RX1510RUGGEDCOM ROX RX1512
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2023-36389
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.47% / 63.52%
||
7 Day CHG~0.00%
Published-11 Jul, 2023 | 09:07
Updated-21 Oct, 2024 | 21:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected application that could allow an attacker to execute malicious javascript code by tricking users into accessing a malicious link. The malformed value is reflected directly in the response without sanitization while throwing an “invalid path” error.

Action-Not Available
Vendor-Siemens AG
Product-ruggedcom_rox_mx5000reruggedcom_rox_rx1511ruggedcom_rox_rx1512_firmwareruggedcom_rox_rx1512ruggedcom_rox_mx5000_firmwareruggedcom_rox_rx1511_firmwareruggedcom_rox_rx1510ruggedcom_rox_rx1400_firmwareruggedcom_rox_rx1500_firmwareruggedcom_rox_rx1400ruggedcom_rox_rx1510_firmwareruggedcom_rox_rx1500ruggedcom_rox_rx1524_firmwareruggedcom_rox_rx5000ruggedcom_rox_rx1501ruggedcom_rox_rx1536ruggedcom_rox_mx5000ruggedcom_rox_rx1524ruggedcom_rox_rx1536_firmwareruggedcom_rox_mx5000re_firmwareruggedcom_rox_rx1501_firmwareruggedcom_rox_rx5000_firmwareRUGGEDCOM ROX MX5000RERUGGEDCOM ROX RX1511RUGGEDCOM ROX RX1536RUGGEDCOM ROX RX1400RUGGEDCOM ROX RX1501RUGGEDCOM ROX RX1500RUGGEDCOM ROX RX5000RUGGEDCOM ROX MX5000RUGGEDCOM ROX RX1524RUGGEDCOM ROX RX1510RUGGEDCOM ROX RX1512
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2021-37201
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.14% / 34.99%
||
7 Day CHG~0.00%
Published-14 Sep, 2021 | 10:47
Updated-04 Aug, 2024 | 01:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP1). The web interface of affected devices is vulnerable to a Cross-Site Request Forgery (CSRF) attack. This could allow an attacker to manipulate the SINEC NMS configuration by tricking an unsuspecting user with administrative privileges to click on a malicious link.

Action-Not Available
Vendor-Siemens AG
Product-sinec_network_management_systemSINEC NMS
CWE ID-CWE-352
Cross-Site Request Forgery (CSRF)
CVE-2021-32936
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.8||HIGH
EPSS-0.17% / 38.28%
||
7 Day CHG~0.00%
Published-17 Jun, 2021 | 00:00
Updated-03 Aug, 2024 | 23:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An out-of-bounds write issue exists in the DXF file-recovering procedure in the Drawings SDK (All versions prior to 2022.4) resulting from the lack of proper validation of user-supplied data. This can result in a write past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or execute code in the context of the current process.

Action-Not Available
Vendor-opendesignn/aSiemens AG
Product-jt2gocomosdrawings_sdkteamcenter_visualizationDrawings SDK
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-37179
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.53% / 66.36%
||
7 Day CHG~0.00%
Published-10 Aug, 2021 | 10:35
Updated-04 Aug, 2024 | 01:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Solid Edge SE2021 (All Versions < SE2021MP7). The PSKERNEL.dll library in affected application lacks proper validation while parsing user-supplied OBJ files that could lead to a use-after-free condition. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13777)

Action-Not Available
Vendor-Siemens AG
Product-solid_edge_se2021solid_edge_se2021_firmwareSolid Edge SE2021
CWE ID-CWE-416
Use After Free
CVE-2021-37180
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.38% / 58.68%
||
7 Day CHG~0.00%
Published-10 Aug, 2021 | 10:35
Updated-04 Aug, 2024 | 01:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Solid Edge SE2021 (All Versions < SE2021MP7). The PSKERNEL.dll library lacks proper validation while parsing user-supplied OBJ files that could cause an out of bounds access to an uninitialized pointer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13775)

Action-Not Available
Vendor-Siemens AG
Product-solid_edge_se2021solid_edge_se2021_firmwareSolid Edge SE2021
CWE ID-CWE-824
Access of Uninitialized Pointer
CVE-2021-37184
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-0.52% / 65.72%
||
7 Day CHG~0.00%
Published-14 Sep, 2021 | 10:47
Updated-04 Aug, 2024 | 01:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Industrial Edge Management (All versions < V1.3). An unauthenticated attacker could change the the password of any user in the system under certain circumstances. With this an attacker could impersonate any valid user on an affected system.

Action-Not Available
Vendor-Siemens AG
Product-industrial_edge_managementIndustrial Edge Management
CWE ID-CWE-639
Authorization Bypass Through User-Controlled Key
CVE-2021-37198
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.14% / 34.95%
||
7 Day CHG~0.00%
Published-11 Jan, 2022 | 11:27
Updated-22 May, 2025 | 19:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in COMOS V10.2 (All versions only if web components are used), COMOS V10.3 (All versions < V10.3.3.3 only if web components are used), COMOS V10.4 (All versions < V10.4.1 only if web components are used). The COMOS Web component of COMOS uses a flawed implementation of CSRF prevention. An attacker could exploit this vulnerability to perform cross-site request forgery attacks.

Action-Not Available
Vendor-Siemens AG
Product-comosCOMOS V10.4COMOS V10.3COMOS V10.2
CWE ID-CWE-352
Cross-Site Request Forgery (CSRF)
CVE-2023-30901
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-4.3||MEDIUM
EPSS-0.12% / 32.32%
||
7 Day CHG~0.00%
Published-13 Jun, 2023 | 08:17
Updated-05 Mar, 2025 | 18:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in POWER METER SICAM Q100 (All versions < V2.60), POWER METER SICAM Q100 (All versions < V2.60), POWER METER SICAM Q100 (All versions < V2.60), POWER METER SICAM Q100 (All versions < V2.60). The web interface of the affected devices are vulnerable to Cross-Site Request Forgery attacks. By tricking an authenticated victim user to click a malicious link, an attacker could perform arbitrary actions on the device on behalf of the victim user.

Action-Not Available
Vendor-Siemens AG
Product-q200q200_firmwarePOWER METER SICAM Q100
CWE ID-CWE-352
Cross-Site Request Forgery (CSRF)
CVE-2021-3672
Matching Score-8
Assigner-Red Hat, Inc.
ShareView Details
Matching Score-8
Assigner-Red Hat, Inc.
CVSS Score-5.6||MEDIUM
EPSS-0.11% / 30.49%
||
7 Day CHG~0.00%
Published-23 Nov, 2021 | 00:00
Updated-15 Oct, 2024 | 17:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A flaw was found in c-ares library, where a missing input validation check of host names returned by DNS (Domain Name Servers) can lead to output of wrong hostnames which might potentially lead to Domain Hijacking. The highest threat from this vulnerability is to confidentiality and integrity as well as system availability.

Action-Not Available
Vendor-pgbouncerc-ares_projectn/aSiemens AGRed Hat, Inc.Fedora ProjectNode.js (OpenJS Foundation)
Product-c-aresenterprise_linux_server_update_services_for_sap_solutionsenterprise_linux_server_ausenterprise_linuxenterprise_linux_computer_nodeenterprise_linux_tusnode.jssinec_infrastructure_network_servicespgbouncerenterprise_linux_workstationfedoraenterprise_linux_for_ibm_z_systemsenterprise_linux_eusenterprise_linux_for_power_little_endian_eusenterprise_linux_server_tusenterprise_linux_for_power_little_endianenterprise_linux_for_ibm_z_systems_eusc-ares
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2021-27398
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.94% / 75.25%
||
7 Day CHG~0.00%
Published-12 May, 2021 | 13:18
Updated-03 Aug, 2024 | 20:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V16.0.5). The PlantSimCore.dll library lacks proper validation of user-supplied data when parsing SPP files. This could result in a stack based buffer overflow, a different vulnerability than CVE-2021-27396. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13290)

Action-Not Available
Vendor-Siemens AG
Product-tecnomatix_plant_simulationTecnomatix Plant Simulation
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2020-15781
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.6||CRITICAL
EPSS-0.50% / 65.14%
||
7 Day CHG~0.00%
Published-14 Aug, 2020 | 15:24
Updated-04 Aug, 2024 | 13:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SICAM WEB firmware for SICAM A8000 RTUs (All versions < V05.30). The login screen does not sufficiently sanitize input, which enables an attacker to generate specially crafted log messages. If an unsuspecting victim views the log messages via the web browser, these log messages might be interpreted and executed as code by the web application. This Cross-Site-Scripting (XSS) vulnerability might compromize the confidentiality, integrity and availability of the web application.

Action-Not Available
Vendor-Siemens AG
Product-sicam_a8000sicam_a8000_firmwareSICAM WEB firmware for SICAM A8000 RTUs
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2021-46699
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.88% / 74.44%
||
7 Day CHG~0.00%
Published-22 Feb, 2022 | 17:52
Updated-04 Aug, 2024 | 05:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Simcenter Femap (All versions < V2022.1.1). Affected application contains a stack based buffer overflow vulnerability while parsing specially crafted BDF files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15061)

Action-Not Available
Vendor-Siemens AG
Product-simcenter_femapSimcenter Femap
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2020-10039
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.1||HIGH
EPSS-0.20% / 42.31%
||
7 Day CHG~0.00%
Published-14 Jul, 2020 | 13:18
Updated-04 Aug, 2024 | 10:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). An attacker in a privileged network position between a legitimate user and the web server might be able to conduct a Man-in-the-middle attack and gain read and write access to the transmitted data.

Action-Not Available
Vendor-Siemens AG
Product-sicam_t_firmwaresicam_mmusicam_sgu_firmwaresicam_mmu_firmwaresicam_sgusicam_tSICAM TSICAM MMUSICAM SGU
CWE ID-CWE-311
Missing Encryption of Sensitive Data
CVE-2020-10045
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.33% / 55.37%
||
7 Day CHG~0.00%
Published-14 Jul, 2020 | 13:18
Updated-04 Aug, 2024 | 10:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). An error in the challenge-response procedure could allow an attacker to replay authentication traffic and gain access to protected areas of the web application.

Action-Not Available
Vendor-Siemens AG
Product-sicam_t_firmwaresicam_mmusicam_sgu_firmwaresicam_mmu_firmwaresicam_sgusicam_tSICAM TSICAM MMUSICAM SGU
CWE ID-CWE-294
Authentication Bypass by Capture-replay
CVE-2021-44447
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.68% / 70.60%
||
7 Day CHG~0.00%
Published-14 Dec, 2021 | 12:07
Updated-04 Aug, 2024 | 04:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT Utilities (All versions < V13.0.3.0), JTTK (All versions < V11.0.3.0). JTTK library in affected products contains a use-after-free vulnerability that could be triggered while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-14911)

Action-Not Available
Vendor-Siemens AG
Product-jt_utilitiesjt_open_toolkitJTTKJT Utilities
CWE ID-CWE-416
Use After Free
CVE-2021-37202
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.45% / 62.65%
||
7 Day CHG~0.00%
Published-14 Sep, 2021 | 10:47
Updated-04 Aug, 2024 | 01:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in NX 1980 Series (All versions < V1984), Solid Edge SE2021 (All versions < SE2021MP8). The IFC adapter in affected application contains a use-after-free vulnerability that could be triggered while parsing user-supplied IFC files. An attacker could leverage this vulnerability to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-nx_1980solid_edgeNX 1980 SeriesSolid Edge SE2021
CWE ID-CWE-416
Use After Free
CVE-2021-34293
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.42% / 60.99%
||
7 Day CHG~0.00%
Published-13 Jul, 2021 | 11:03
Updated-04 Aug, 2024 | 00:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The Gif_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing GIF files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13020)

Action-Not Available
Vendor-Siemens AG
Product-jt2goteamcenter_visualizationJT2GoTeamcenter Visualization
CWE ID-CWE-787
Out-of-bounds Write
CWE ID-CWE-20
Improper Input Validation
  • Previous
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • Next
Details not found