On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an SSH login can succeed with hardcoded default credentials (if the device is in the uncommissioned state).
CWE-200: Information Exposure vulnerability exists that could cause disclosure of credentials when a specially crafted message is sent to the device.
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'system.opkg.remove'.
CWE-787: Out-of-bounds Write vulnerability exists that could result in an authentication bypass when sending a malformed POST request and particular configuration parameters are set.
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'model_name' or 'mac_address'.
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to bypass authentication and get the administrator privileges.
A Permissions, Privileges, and Access Control vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to overwrite the original password with their password. If an attacker exploits this vulnerability and overwrite the password, the attacker can upload the original program from the PLC.
A Credentials Management CWE-255 vulnerability exists in the APC UPS Network Management Card 2 AOS v6.5.6, which could cause Remote Monitoring Credentials to be viewed in plaintext when Remote Monitoring is enabled, and then disabled.
A Hard-coded Credentials vulnerability exists in EVLink Parking, v3.2.0-12_v1 and earlier, which could enable an attacker to gain access to the device.
A SQL Injection (CWE-89) vulnerability exists in U.motion Builder software version 1.3.4 which could cause unwanted code execution when an improper set of characters is entered.
A CWE-501: Trust Boundary Violation vulnerability on connection to the Controller exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum and Modicon Premium which could cause unauthorized access by conducting a brute force attack on Modbus protocol to the controller.
An authorization bypass vulnerability exists In Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS. The integrated web server (Port 80/443/TCP) of the affected devices could allow a remote attacker to get a full access to device, bypassing the authorization system.
A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service or potential code execution by overwriting configuration settings of the controller over Modbus.
A buffer overflow vulnerability exist in the web-based GUI of Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to execute arbitrary code.
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to bypass authentication and gain administrator privileges because the use of hardcoded credentials.
A CWE-290: Authentication Bypass by Spoofing vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause an elevation of privilege by conducting a brute force attack on Modbus parameters sent to the controller.
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'network.ieee8021x.delete_certs'.
The FTP server on the Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware through 1.60 IR 04 has hardcoded credentials, which makes it easier for remote attackers to obtain access via an FTP session.
An Information Management Error vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to replay authentication sequences. If an attacker exploits this vulnerability and connects to a Modicon M221, the attacker can upload the original program from the PLC.
Buffer overflow in an ActiveX control in Atx45.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8512. NOTE: this may be clarified later based on details provided by researchers.
A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Including all Unity Pro versions (former name of EcoStruxure Control Expert) (V15.0 SP1 and prior), EcoStruxure Process Expert, Including all versions of EcoStruxure Hybrid DCS (former name of EcoStruxure Process Expert) (V2021 and prior), Modicon M340 CPU (part numbers BMXP34*) (V3.40 and prior), Modicon M580 CPU (part numbers BMEP* and BMEH*) (V3.20 and prior).
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted setting value messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)
The Schneider Electric Magelis XBT HMI controller has a default password for authentication of configuration uploads, which makes it easier for remote attackers to bypass intended access restrictions via crafted configuration data.
A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection'), reflective DLL, vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior to V3.10), which, if exploited, could allow attackers to transfer malicious code to the controller.
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in SFAPV9601 - APC Easy UPS On-Line Software (V2.0 and earlier) when accessing a vulnerable method of `FileUploadServlet` which may lead to uploading executable files to non-specified directories.
A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause unauthenticated command execution in the controller when sending special HTTP requests.
CWE-287: Improper Authentication vulnerability exists which could cause the execution of commands on the webserver without authentication when sending specially crafted HTTP requests.
A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could cause brute force attacks to take over the admin account when the product does not implement a rate limit mechanism on the admin authentication form. Affected Products: Conext™ ComBox (All Versions)
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that could cause remote code execution when an admin user on DCE tampers with backups which are then manually restored.
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that could cause remote code execution when an admin user on DCE uploads or tampers with install packages.
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that could cause execution of malicious code when an unsuspicious user loads a project file from the local filesystem into the HMI.
An issue was discovered in Schneider Electric Unity PRO prior to V11.1. Unity projects can be compiled as x86 instructions and loaded onto the PLC Simulator delivered with Unity PRO. These x86 instructions are subsequently executed directly by the simulator. A specially crafted patched Unity project file can make the simulator execute malicious code by redirecting the control flow of these instructions.
A Code Injection vulnerability exists in EVLink Parking, v3.2.0-12_v1 and earlier, which could enable access with maximum privileges when a remote code execution is performed.
In Modicon Quantum all firmware versions, a CWE-94: Code Injection vulnerability could cause an unauthorized firmware modification with possible Denial of Service when using Modbus protocol.
A code injection vulnerability exists within the firewall software of GlassWire v2.1.167 that could lead to arbitrary code execution from a file in the user path on first execution.
myBB version 1.6.4 was distributed with an unauthorized backdoor embedded in the source code. The backdoor allowed remote attackers to execute arbitrary PHP code by injecting payloads into a specially crafted collapsed cookie. This vulnerability was introduced during packaging and was not part of the intended application logic. Exploitation requires no authentication and results in full compromise of the web server under the context of the web application.
An arbitrary code injection vector was found in PouchDB 6.0.4 and lesser via the map/reduce functions used in PouchDB temporary views and design documents. The code execution engine for this branch is not properly sandboxed and may be used to run arbitrary JavaScript as well as system commands.
The Management Console (webagent.exe) in Cisco Security Agent 5.1, 5.2, and 6.0 before 6.0.2.145 allows remote attackers to create arbitrary files and execute arbitrary code via unspecified parameters in a crafted st_upload request.
A vulnerability was found in PbootCMS up to 3.2.3. It has been classified as critical. This affects an unknown part of the file apps/home/controller/IndexController.php. The manipulation of the argument tag leads to code injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. Upgrading to version 3.2.4 is able to address this issue. It is recommended to upgrade the affected component.
The “ipk” package containing the configuration created by TWinSoft can be uploaded, extracted, and executed in Ovarro TBox, allowing malicious code execution.
Code injection in pluginconfig.php in Image Uploader and Browser for CKEditor before 4.1.9 allows remote authenticated users to execute arbitrary PHP code.
A vulnerability classified as critical has been found in FoxCMS up to 1.2. Affected is an unknown function of the file /install/installdb.php of the component Configuration File Handler. The manipulation of the argument database password leads to code injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
The Avada | Website Builder For WordPress & WooCommerce theme for WordPress is vulnerable to arbitrary shortcode execution in all versions up to, and including, 7.11.13. This is due to the software allowing users to execute an action that does not properly validate a value before running do_shortcode. This makes it possible for unauthenticated attackers to execute arbitrary shortcodes.
Chamilo LMS version 11.x contains an Unserialization vulnerability in the "hash" GET parameter for the api endpoint located at /webservices/api/v2.php that can result in Unauthenticated remote code execution. This attack appear to be exploitable via a simple GET request to the api endpoint. This vulnerability appears to have been fixed in After commit 0de84700648f098c1fbf6b807dee28ec640efe62.
The network-play implementation in Mednafen before 0.8.D might allow remote servers to execute arbitrary code via unspecified vectors, related to "stack manipulation" issues.
Unspecified vulnerability in IBM Tivoli Storage Manager (TSM) FastBack 5.5.0.0 through 5.5.6.0 and 6.1.0.0 through 6.1.0.1 allows remote attackers to execute arbitrary code via unknown vectors, aka ZDI-CAN-700. NOTE: this might overlap CVE-2010-3058 or CVE-2010-3059.
parserIfLabel in inc/zzz_template.php in ZZZCMS zzzphp 1.7.3 allows remote attackers to execute arbitrary code because the danger_key function can be bypassed via manipulations such as strtr.
An internal security review has identified an unauthenticated remote code execution vulnerability in Cloud Networking Operating System (CNOS)’ optional REST API management interface. This interface is disabled by default and not vulnerable unless enabled. When enabled, it is only vulnerable where attached to a VRF and as allowed by defined ACLs. Lenovo strongly recommends upgrading to a non-vulnerable CNOS release. Where not possible, Lenovo recommends disabling the REST API management interface or restricting access to the management VRF and further limiting access to authorized management stations via ACL.
Adobe Flash Media Server (FMS) 3.0.x before 3.0.7, 3.5.x before 3.5.5, and 4.0.x before 4.0.1 allows attackers to execute arbitrary code via unspecified vectors, related to a "segmentation fault vulnerability."
Adobe Flash Media Server (FMS) before 3.0.6, and 3.5.x before 3.5.4, allows attackers to execute arbitrary code via unspecified vectors, related to a "JS method vulnerability."