Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2019-6823

Summary
Assigner-schneider
Assigner Org ID-076d1eb6-cfab-4401-b34d-6dfc2a413bdb
Published At-15 Jul, 2019 | 20:41
Updated At-04 Aug, 2024 | 20:31
Rejected At-
Credits

A CWE-94: Code Injection vulnerability exists in ProClima (all versions prior to version 8.0.0) which could allow an unauthenticated, remote attacker to execute arbitrary code on the targeted system in all versions of ProClima prior to version 8.0.0.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:schneider
Assigner Org ID:076d1eb6-cfab-4401-b34d-6dfc2a413bdb
Published At:15 Jul, 2019 | 20:41
Updated At:04 Aug, 2024 | 20:31
Rejected At:
▼CVE Numbering Authority (CNA)

A CWE-94: Code Injection vulnerability exists in ProClima (all versions prior to version 8.0.0) which could allow an unauthenticated, remote attacker to execute arbitrary code on the targeted system in all versions of ProClima prior to version 8.0.0.

Affected Products
Vendor
Schneider Electric SEProClima
Product
ProClima all versions prior to version 8.0.0
Versions
Affected
  • ProClima all versions prior to version 8.0.0
Problem Types
TypeCWE IDDescription
CWECWE-94CWE-94: Code Injection
Type: CWE
CWE ID: CWE-94
Description: CWE-94: Code Injection
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.schneider-electric.com/en/download/document/SEVD-2019-162-01/
x_refsource_MISC
Hyperlink: https://www.schneider-electric.com/en/download/document/SEVD-2019-162-01/
Resource:
x_refsource_MISC
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.schneider-electric.com/en/download/document/SEVD-2019-162-01/
x_refsource_MISC
x_transferred
Hyperlink: https://www.schneider-electric.com/en/download/document/SEVD-2019-162-01/
Resource:
x_refsource_MISC
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cybersecurity@se.com
Published At:15 Jul, 2019 | 21:15
Updated At:14 Oct, 2022 | 03:03

A CWE-94: Code Injection vulnerability exists in ProClima (all versions prior to version 8.0.0) which could allow an unauthenticated, remote attacker to execute arbitrary code on the targeted system in all versions of ProClima prior to version 8.0.0.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.19.8CRITICAL
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Primary2.010.0HIGH
AV:N/AC:L/Au:N/C:C/I:C/A:C
Type: Primary
Version: 3.1
Base score: 9.8
Base severity: CRITICAL
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 2.0
Base score: 10.0
Base severity: HIGH
Vector:
AV:N/AC:L/Au:N/C:C/I:C/A:C
CPE Matches

Schneider Electric SE
schneider-electric
>>proclima>>Versions before 8.0.0(exclusive)
cpe:2.3:a:schneider-electric:proclima:*:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-94Primarynvd@nist.gov
CWE-94Secondarycybersecurity@se.com
CWE ID: CWE-94
Type: Primary
Source: nvd@nist.gov
CWE ID: CWE-94
Type: Secondary
Source: cybersecurity@se.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://www.schneider-electric.com/en/download/document/SEVD-2019-162-01/cybersecurity@se.com
Vendor Advisory
Hyperlink: https://www.schneider-electric.com/en/download/document/SEVD-2019-162-01/
Source: cybersecurity@se.com
Resource:
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

1015Records found

CVE-2021-30064
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.06% / 17.87%
||
7 Day CHG~0.00%
Published-03 Apr, 2022 | 21:56
Updated-03 Aug, 2024 | 22:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an SSH login can succeed with hardcoded default credentials (if the device is in the uncommissioned state).

Action-Not Available
Vendor-beldenn/a
Product-tofino_argon_fa-tsa-220-mm\/txeagle_20_tofino_943_987-504-mm\/txtofino_argon_fa-tsa-220-tx\/txtcsefea23f3f21_firmwareeagle_20_tofino_943_987-502_-tx\/mm_firmwareeagle_20_tofino_943_987-501-tx\/txtofino_argon_fa-tsa-220-mm\/tx_firmwaretofino_argon_fa-tsa-100-tx\/txtofino_xenon_security_appliance_firmwareeagle_20_tofino_943_987-501-tx\/tx_firmwaretcsefea23f3f21eagle_20_tofino_943_987-504-mm\/tx_firmwaretofino_argon_fa-tsa-220-tx\/mm_firmwaretofino_xenon_security_appliancetofino_argon_fa-tsa-100-tx\/tx_firmwareeagle_20_tofino_943_987-502_-tx\/mmtcsefea23f3f22_firmwaretofino_argon_fa-tsa-220-tx\/tx_firmwareeagle_20_tofino_943_987-505-mm\/mmtofino_argon_fa-tsa-220-tx\/mmtcsefea23f3f22eagle_20_tofino_943_987-505-mm\/mm_firmwaretofino_argon_fa-tsa-220-mm\/mmtcsefea23f3f20tofino_argon_fa-tsa-220-mm\/mm_firmwaretcsefea23f3f20_firmwaren/a
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2024-6407
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.38% / 58.49%
||
7 Day CHG+0.16%
Published-11 Jul, 2024 | 09:07
Updated-01 Aug, 2024 | 21:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-200: Information Exposure vulnerability exists that could cause disclosure of credentials when a specially crafted message is sent to the device.

Action-Not Available
Vendor-
Product-whc-5918awhc-5918a_firmwareWiser Home Controller WHC-5918A
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2018-7231
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.20% / 78.10%
||
7 Day CHG~0.00%
Published-09 Mar, 2018 | 23:00
Updated-16 Sep, 2024 | 19:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'system.opkg.remove'.

Action-Not Available
Vendor-
Product-imp519-1er_firmwareibp319-1erimp319-1erimps110-1eibp519-1er_firmwareimp1110-1er_firmwareimps110-1eribp1110-1erimp519-1_firmwareimp519-1ibps110-1er_firmwareimp219-1_firmwareimp319-1_firmwareimps110-1er_firmwareimp219-1erimp319-1mps110-1ibp319-1er_firmwareimp319-1er_firmwareimps110-1e_firmwareimp219-1e_firmwareimp219-1eibp219-1erimp1110-1e_firmwareimp1110-1_firmwareimp519-1eimp319-1e_firmwareimp1110-1erimp219-1ibp219-1er_firmwareimp519-1erimp1110-1eimp319-1eibp1110-1er_firmwareibps110-1erimp219-1er_firmwareimp519-1e_firmwareimp1110-1ibp519-1ermps110-1_firmwarePelco Sarix Professional
CWE ID-CWE-20
Improper Input Validation
CVE-2024-37036
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.06% / 20.22%
||
7 Day CHG~0.00%
Published-12 Jun, 2024 | 16:48
Updated-14 Aug, 2024 | 14:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-787: Out-of-bounds Write vulnerability exists that could result in an authentication bypass when sending a malformed POST request and particular configuration parameters are set.

Action-Not Available
Vendor-
Product-sage_4400sage_1410sage_3030_magnumsage_2400sage_rtu_firmwaresage_1450sage_1430Sage 4400Sage 1450Sage 1410Sage 3030 MagnumSage 1430Sage 2400sage_4400_firmware
CWE ID-CWE-787
Out-of-bounds Write
CVE-2018-7233
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.20% / 78.10%
||
7 Day CHG~0.00%
Published-09 Mar, 2018 | 23:00
Updated-17 Sep, 2024 | 01:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'model_name' or 'mac_address'.

Action-Not Available
Vendor-
Product-imp519-1er_firmwareibp319-1erimp319-1erimps110-1eibp519-1er_firmwareimp1110-1er_firmwareimps110-1eribp1110-1erimp519-1_firmwareimp519-1ibps110-1er_firmwareimp219-1_firmwareimp319-1_firmwareimps110-1er_firmwareimp219-1erimp319-1mps110-1ibp319-1er_firmwareimp319-1er_firmwareimps110-1e_firmwareimp219-1e_firmwareimp219-1eibp219-1erimp1110-1e_firmwareimp1110-1_firmwareimp519-1eimp319-1e_firmwareimp1110-1erimp219-1ibp219-1er_firmwareimp519-1erimp1110-1eimp319-1eibp1110-1er_firmwareibps110-1erimp219-1er_firmwareimp519-1e_firmwareimp1110-1ibp519-1ermps110-1_firmwarePelco Sarix Professional
CWE ID-CWE-20
Improper Input Validation
CVE-2018-7228
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.73% / 71.79%
||
7 Day CHG~0.00%
Published-09 Mar, 2018 | 23:00
Updated-16 Sep, 2024 | 23:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to bypass authentication and get the administrator privileges.

Action-Not Available
Vendor-
Product-imp519-1er_firmwareibp319-1erimp319-1erimps110-1eibp519-1er_firmwareimp1110-1er_firmwareimps110-1eribp1110-1erimp519-1_firmwareimp519-1ibps110-1er_firmwareimp219-1_firmwareimp319-1_firmwareimps110-1er_firmwareimp219-1erimp319-1mps110-1ibp319-1er_firmwareimp319-1er_firmwareimps110-1e_firmwareimp219-1e_firmwareimp219-1eibp219-1erimp1110-1e_firmwareimp1110-1_firmwareimp519-1eimp319-1e_firmwareimp1110-1erimp219-1ibp219-1er_firmwareimp519-1erimp1110-1eimp319-1eibp1110-1er_firmwareibps110-1erimp219-1er_firmwareimp519-1e_firmwareimp1110-1ibp519-1ermps110-1_firmwarePelco Sarix Professional
CWE ID-CWE-287
Improper Authentication
CVE-2018-7791
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.34% / 55.66%
||
7 Day CHG~0.00%
Published-29 Aug, 2018 | 21:00
Updated-17 Sep, 2024 | 04:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Permissions, Privileges, and Access Control vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to overwrite the original password with their password. If an attacker exploits this vulnerability and overwrite the password, the attacker can upload the original program from the PLC.

Action-Not Available
Vendor-
Product-modicon_m221_firmwaremodicon_m221Modicon M221, all references, all versions prior to firmware V1.6.2.0
CWE ID-CWE-287
Improper Authentication
CVE-2018-7820
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.28% / 51.19%
||
7 Day CHG~0.00%
Published-17 Sep, 2019 | 19:45
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Credentials Management CWE-255 vulnerability exists in the APC UPS Network Management Card 2 AOS v6.5.6, which could cause Remote Monitoring Credentials to be viewed in plaintext when Remote Monitoring is enabled, and then disabled.

Action-Not Available
Vendor-
Product-ap9630ap9631ap9635smart-ups_srt_5kvaap9635_firmwareap9630_firmwaresmart-ups_srt_5kva_firmwareap9631_firmwareAPC UPS Network Management Card 2 AOS
CWE ID-CWE-255
Not Available
CWE ID-CWE-522
Insufficiently Protected Credentials
CVE-2018-7800
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.17% / 77.84%
||
7 Day CHG~0.00%
Published-24 Dec, 2018 | 16:00
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Hard-coded Credentials vulnerability exists in EVLink Parking, v3.2.0-12_v1 and earlier, which could enable an attacker to gain access to the device.

Action-Not Available
Vendor-
Product-evlink_parkingevlink_parking_firmwareEVLink Parking v3.2.0-12_v1 and earlier
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2018-7841
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-59.14% / 98.15%
||
7 Day CHG+20.04%
Published-22 May, 2019 | 19:20
Updated-30 Jul, 2025 | 01:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Known KEV||Action Due Date - 2022-05-06||The impacted product is end-of-life and should be disconnected if still in use.

A SQL Injection (CWE-89) vulnerability exists in U.motion Builder software version 1.3.4 which could cause unwanted code execution when an improper set of characters is entered.

Action-Not Available
Vendor-U.motionSchneider Electric SE
Product-u.motion_builderU.motion Builder software version 1.3.4U.motion Builder
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2018-7846
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-38.19% / 97.12%
||
7 Day CHG~0.00%
Published-22 May, 2019 | 19:57
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-501: Trust Boundary Violation vulnerability on connection to the Controller exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum and Modicon Premium which could cause unauthorized access by conducting a brute force attack on Modbus protocol to the controller.

Action-Not Available
Vendor-n/a
Product-modicon_quantummodicon_quantum_firmwaremodicon_m580_firmwaremodicon_premium_firmwaremodicon_premiummodicon_m340modicon_m340_firmwaremodicon_m580Modicon M580 Modicon M340 Modicon Quantum Modicon Premium
CWE ID-CWE-668
Exposure of Resource to Wrong Sphere
CVE-2018-7243
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-2.35% / 84.28%
||
7 Day CHG~0.00%
Published-18 Apr, 2018 | 20:00
Updated-05 Aug, 2024 | 06:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An authorization bypass vulnerability exists In Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS. The integrated web server (Port 80/443/TCP) of the affected devices could allow a remote attacker to get a full access to device, bypassing the authorization system.

Action-Not Available
Vendor-
Product-mge_galaxy_4000mge_galaxy_5000mge_eps_8000mge_galaxy_pwmge_galaxy_300066074_mge_network_management_card_transversemge_comet_upsmge_eps_6000mge_galaxy_6000mge_galaxy_9000mge_eps_700066074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS
CVE-2018-7847
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.22% / 78.29%
||
7 Day CHG~0.00%
Published-22 May, 2019 | 20:00
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service or potential code execution by overwriting configuration settings of the controller over Modbus.

Action-Not Available
Vendor-n/a
Product-modicon_quantummodicon_quantum_firmwaremodicon_m580_firmwaremodicon_premium_firmwaremodicon_premiummodicon_m340modicon_m340_firmwaremodicon_m580Modicon M580 Modicon M340 Modicon Quantum Modicon Premium
CWE ID-CWE-287
Improper Authentication
CVE-2018-7238
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-2.73% / 85.39%
||
7 Day CHG~0.00%
Published-09 Mar, 2018 | 23:00
Updated-16 Sep, 2024 | 16:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A buffer overflow vulnerability exist in the web-based GUI of Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to execute arbitrary code.

Action-Not Available
Vendor-
Product-imp519-1er_firmwareibp319-1erimp319-1erimps110-1eibp519-1er_firmwareimp1110-1er_firmwareimps110-1eribp1110-1erimp519-1_firmwareimp519-1ibps110-1er_firmwareimp219-1_firmwareimp319-1_firmwareimps110-1er_firmwareimp219-1erimp319-1mps110-1ibp319-1er_firmwareimp319-1er_firmwareimps110-1e_firmwareimp219-1e_firmwareimp219-1eibp219-1erimp1110-1e_firmwareimp1110-1_firmwareimp519-1eimp319-1e_firmwareimp1110-1erimp219-1ibp219-1er_firmwareimp519-1erimp1110-1eimp319-1eibp1110-1er_firmwareibps110-1erimp219-1er_firmwareimp519-1e_firmwareimp1110-1ibp519-1ermps110-1_firmwarePelco Sarix Professional
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2018-7229
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.54% / 66.58%
||
7 Day CHG~0.00%
Published-09 Mar, 2018 | 23:00
Updated-16 Sep, 2024 | 19:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to bypass authentication and gain administrator privileges because the use of hardcoded credentials.

Action-Not Available
Vendor-
Product-imp519-1er_firmwareibp319-1erimp319-1erimps110-1eibp519-1er_firmwareimp1110-1er_firmwareimps110-1eribp1110-1erimp519-1_firmwareimp519-1ibps110-1er_firmwareimp219-1_firmwareimp319-1_firmwareimps110-1er_firmwareimp219-1erimp319-1mps110-1ibp319-1er_firmwareimp319-1er_firmwareimps110-1e_firmwareimp219-1e_firmwareimp219-1eibp219-1erimp1110-1e_firmwareimp1110-1_firmwareimp519-1eimp319-1e_firmwareimp1110-1erimp219-1ibp219-1er_firmwareimp519-1erimp1110-1eimp319-1eibp1110-1er_firmwareibps110-1erimp219-1er_firmwareimp519-1e_firmwareimp1110-1ibp519-1ermps110-1_firmwarePelco Sarix Professional
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2018-7842
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-6.47% / 90.69%
||
7 Day CHG~0.00%
Published-22 May, 2019 | 19:59
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-290: Authentication Bypass by Spoofing vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause an elevation of privilege by conducting a brute force attack on Modbus parameters sent to the controller.

Action-Not Available
Vendor-n/a
Product-modicon_quantummodicon_quantum_firmwaremodicon_m580_firmwaremodicon_premium_firmwaremodicon_premiummodicon_m340modicon_m340_firmwaremodicon_m580Modicon M580 Modicon M340 Modicon Quantum Modicon Premium
CWE ID-CWE-290
Authentication Bypass by Spoofing
CVE-2018-7232
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.20% / 78.10%
||
7 Day CHG~0.00%
Published-09 Mar, 2018 | 23:00
Updated-17 Sep, 2024 | 00:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'network.ieee8021x.delete_certs'.

Action-Not Available
Vendor-
Product-imp519-1er_firmwareibp319-1erimp319-1erimps110-1eibp519-1er_firmwareimp1110-1er_firmwareimps110-1eribp1110-1erimp519-1_firmwareimp519-1ibps110-1er_firmwareimp219-1_firmwareimp319-1_firmwareimps110-1er_firmwareimp219-1erimp319-1mps110-1ibp319-1er_firmwareimp319-1er_firmwareimps110-1e_firmwareimp219-1e_firmwareimp219-1eibp219-1erimp1110-1e_firmwareimp1110-1_firmwareimp519-1eimp319-1e_firmwareimp1110-1erimp219-1ibp219-1er_firmwareimp519-1erimp1110-1eimp319-1eibp1110-1er_firmwareibps110-1erimp219-1er_firmwareimp519-1e_firmwareimp1110-1ibp519-1ermps110-1_firmwarePelco Sarix Professional
CWE ID-CWE-20
Improper Input Validation
CVE-2014-9198
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-10||HIGH
EPSS-0.68% / 70.64%
||
7 Day CHG~0.00%
Published-27 Jan, 2015 | 11:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The FTP server on the Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware through 1.60 IR 04 has hardcoded credentials, which makes it easier for remote attackers to obtain access via an FTP session.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-tsxetg3022tsxetg3010etg3000_factorycast_hmi_gateway_firmwaretsxetg3021tsxetg3000n/a
CVE-2018-7790
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.49% / 64.64%
||
7 Day CHG~0.00%
Published-29 Aug, 2018 | 21:00
Updated-16 Sep, 2024 | 19:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An Information Management Error vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to replay authentication sequences. If an attacker exploits this vulnerability and connects to a Modicon M221, the attacker can upload the original program from the PLC.

Action-Not Available
Vendor-
Product-modicon_m221_firmwaremodicon_m221Modicon M221, all references, all versions prior to firmware V1.6.2.0
CWE ID-CWE-294
Authentication Bypass by Capture-replay
CVE-2014-8511
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-10||HIGH
EPSS-5.35% / 89.70%
||
7 Day CHG~0.00%
Published-27 Dec, 2014 | 15:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Buffer overflow in an ActiveX control in Atx45.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8512. NOTE: this may be clarified later based on details provided by researchers.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-procliman/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2022-37300
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.29% / 51.88%
||
7 Day CHG~0.00%
Published-12 Sep, 2022 | 17:40
Updated-03 Aug, 2024 | 10:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Including all Unity Pro versions (former name of EcoStruxure Control Expert) (V15.0 SP1 and prior), EcoStruxure Process Expert, Including all versions of EcoStruxure Hybrid DCS (former name of EcoStruxure Process Expert) (V2021 and prior), Modicon M340 CPU (part numbers BMXP34*) (V3.40 and prior), Modicon M580 CPU (part numbers BMEP* and BMEH*) (V3.20 and prior).

Action-Not Available
Vendor-
Product-modicon_m340_bmxp342030_firmwaremodicon_m340_bmxp3420302h_firmwaremodicon_m340_bmxp342020h_firmwaremodicon_m580_bmep583040_firmwaremodicon_m580_bmeh582040smodicon_m340_bmxp3420302_firmwaremodicon_m340_bmxp342010modicon_m580_bmeh584040smodicon_m580_bmep582020h_firmwaremodicon_m580_bmep584040s_firmwaremodicon_m580_bmep584040modicon_m340_bmxp342010_firmwaremodicon_m340_bmxp342020_firmwaremodicon_m340_bmxp3420102_firmwaremodicon_m580_bmep585040_firmwaremodicon_m580_bmep582040h_firmwaremodicon_m580_bmep584040_firmwaremodicon_m580_bmep584040smodicon_m580_bmeh582040cmodicon_m580_bmep583040ecostruxure_control_expertmodicon_m580_bmep582040modicon_m580_bmep584020_firmwaremodicon_m580_bmeh584040modicon_m580_bmep585040modicon_m580_bmep585040c_firmwaremodicon_m580_bmeh584040_firmwaremodicon_m580_bmep581020h_firmwaremodicon_m580_bmep584020modicon_m580_bmeh584040s_firmwaremodicon_m340_bmxp342020modicon_m340_bmxp342030hmodicon_m340_bmxp342020hmodicon_m580_bmeh586040cmodicon_m580_bmep582020_firmwaremodicon_m340_bmxp342000_firmwaremodicon_m580_bmeh586040_firmwaremodicon_m580_bmep581020hmodicon_m580_bmeh584040cmodicon_m340_bmxp342030modicon_m580_bmeh586040c_firmwaremodicon_m580_bmep586040_firmwaremodicon_m580_bmeh582040_firmwaremodicon_m580_bmep582040_firmwaremodicon_m580_bmeh582040modicon_m580_bmeh582040c_firmwaremodicon_m580_bmep583020modicon_m580_bmeh586040s_firmwaremodicon_m580_bmeh586040smodicon_m580_bmep586040modicon_m340_bmxp342000modicon_m580_bmeh586040modicon_m580_bmep582020modicon_m580_bmep583020_firmwaremodicon_m340_bmxp341000modicon_m580_bmeh584040c_firmwaremodicon_m340_bmxp3420302hmodicon_m580_bmep585040cmodicon_m580_bmep582040hmodicon_m340_bmxp3420302modicon_m340_bmxp341000_firmwaremodicon_m580_bmep581020_firmwareecostruxure_process_expertmodicon_m580_bmep581020modicon_m580_bmep586040cmodicon_m340_bmxp342030h_firmwaremodicon_m580_bmep582020hmodicon_m580_bmep586040c_firmwaremodicon_m340_bmxp3420102modicon_m580_bmeh582040s_firmwareEcoStruxure Control ExpertEcoStruxure Process ExpertModicon M340 CPUModicon M580 CPU
CWE ID-CWE-640
Weak Password Recovery Mechanism for Forgotten Password
CVE-2022-32526
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-3.61% / 87.33%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted setting value messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)

Action-Not Available
Vendor-Schneider Electric SE
Product-interactive_graphical_scada_systemIGSS Data Server (IGSSdataServer.exe)
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2013-2762
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-10||HIGH
EPSS-0.08% / 24.63%
||
7 Day CHG~0.00%
Published-04 Apr, 2013 | 10:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The Schneider Electric Magelis XBT HMI controller has a default password for authentication of configuration uploads, which makes it easier for remote attackers to bypass intended access restrictions via crafted configuration data.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-magelis_xbt_hmin/a
CWE ID-CWE-352
Cross-Site Request Forgery (CSRF)
CVE-2020-7475
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.57% / 67.66%
||
7 Day CHG~0.00%
Published-23 Mar, 2020 | 18:56
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection'), reflective DLL, vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior to V3.10), which, if exploited, could allow attackers to transfer malicious code to the controller.

Action-Not Available
Vendor-n/a
Product-ecostruxure_control_expertmodicon_m580_firmwareunity_promodicon_m340modicon_m340_firmwaremodicon_m580EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior to V3.10)
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CVE-2020-7521
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.73% / 71.83%
||
7 Day CHG~0.00%
Published-31 Aug, 2020 | 16:10
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in SFAPV9601 - APC Easy UPS On-Line Software (V2.0 and earlier) when accessing a vulnerable method of `FileUploadServlet` which may lead to uploading executable files to non-specified directories.

Action-Not Available
Vendor-n/a
Product-apc_easy_ups_online_softwareSFAPV9601 - APC Easy UPS On-Line Software V2.0 and earlier
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2020-7540
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.31% / 53.68%
||
7 Day CHG~0.00%
Published-11 Dec, 2020 | 00:52
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause unauthenticated command execution in the controller when sending special HTTP requests.

Action-Not Available
Vendor-n/a
Product-140noc78100140cpu65150140noc78000_firmwaretsxp575634_firmware140noc78000bmxnoe0110_firmware140cpu65160_firmwaretsxp574634modicon_m340_bmxp3420102clmodicon_m340_bmxp3420302_firmwarebmxnor200h_firmware140noc78100_firmwaremodicon_m340_bmxp342000140cpu65160modicon_m340_bmxp3420302cl_firmwaremodicon_m340_bmxp341000140noe77111_firmwaremodicon_m340_bmxp342020_firmware140noc77101_firmwaremodicon_m340_bmxp3420102_firmware140noc77101bmxnoe0110140noe77101tsxety5103_firmwaremodicon_m340_bmxp3420102cl_firmwaretsxety5103tsxp574634_firmwarebmxnoc0401_firmware140noe77111modicon_m340_bmxp3420302clmodicon_m340_bmxp3420302140noe77101_firmwaremodicon_m340_bmxp342020bmxnoe0100_firmwaretsxp576634modicon_m340_bmxp341000_firmwaretsxety4103_firmwarebmxnor200htsxp576634_firmwarebmxnoc0401modicon_m340_bmxp342000_firmwarebmxnoe0100140cpu65150_firmwaremodicon_m340_bmxp3420102tsxety4103tsxp575634Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions)
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2020-7533
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.24% / 46.22%
||
7 Day CHG~0.00%
Published-01 Dec, 2020 | 14:47
Updated-10 Jun, 2025 | 08:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-287: Improper Authentication vulnerability exists which could cause the execution of commands on the webserver without authentication when sending specially crafted HTTP requests.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-140noc78000tsxp574634_firmwaretsxp574634140cpu65260_firmwaretsxety4103tsxp575634modicon_m340_bmxp342000modicon_m340_bmxp3420302_firmwarebmxnoe0100modicon_m340_bmxp342000_firmwarebmxnoe0110_firmwaretsxety5103_firmwaretsxp576634140noe77111_firmwaremodicon_m340_bmxp341000modicon_m340_bmxp3420102_firmwaremodicon_m340_bmxp341000_firmwarebmxnoe0110tsxp575634_firmware140noe77111bmxnoe0100_firmwarebmxnoc0401_firmware140noc77101140cpu65260bmxnoc0401140noc77101_firmwaretsxety4103_firmwaremodicon_m340_bmxp3420302140noc78000_firmwaretsxp576634_firmwaremodicon_m340_bmxp3420102tsxety5103Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules (see security notification for version information)
CWE ID-CWE-287
Improper Authentication
CVE-2022-32515
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.6||HIGH
EPSS-0.16% / 36.93%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could cause brute force attacks to take over the admin account when the product does not implement a rate limit mechanism on the admin authentication form. Affected Products: Conext™ ComBox (All Versions)

Action-Not Available
Vendor-Schneider Electric SE
Product-conext_comboxconext_combox_firmwareConext™ ComBox
CWE ID-CWE-307
Improper Restriction of Excessive Authentication Attempts
CVE-2023-37199
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-6.8||MEDIUM
EPSS-1.69% / 81.47%
||
7 Day CHG~0.00%
Published-12 Jul, 2023 | 07:04
Updated-07 Nov, 2024 | 14:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that could cause remote code execution when an admin user on DCE tampers with backups which are then manually restored.

Action-Not Available
Vendor-
Product-struxureware_data_center_expertStruxureWare Data Center Expert struxureware_data_center_expert
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2023-37198
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-6.8||MEDIUM
EPSS-1.64% / 81.19%
||
7 Day CHG~0.00%
Published-12 Jul, 2023 | 06:44
Updated-07 Nov, 2024 | 14:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that could cause remote code execution when an admin user on DCE uploads or tampers with install packages.

Action-Not Available
Vendor-
Product-struxureware_data_center_expertStruxureWare Data Center Expert struxureware_data_center_expert
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2023-1049
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.10% / 28.58%
||
7 Day CHG~0.00%
Published-14 Jun, 2023 | 07:27
Updated-02 Jan, 2025 | 20:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that could cause execution of malicious code when an unsuspicious user loads a project file from the local filesystem into the HMI.

Action-Not Available
Vendor-
Product-ecostruxure_operator_terminal_expertpro-face_blueEcoStruxure™ Operator Terminal ExpertPro-face BLUE
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2016-8354
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7||HIGH
EPSS-0.16% / 37.84%
||
7 Day CHG~0.00%
Published-13 Feb, 2017 | 21:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in Schneider Electric Unity PRO prior to V11.1. Unity projects can be compiled as x86 instructions and loaded onto the PLC Simulator delivered with Unity PRO. These x86 instructions are subsequently executed directly by the simulator. A specially crafted patched Unity project file can make the simulator execute malicious code by redirecting the control flow of these instructions.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-unity_proSchneider Electric Unity PRO Control prior to V11.1
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2018-7801
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-16.84% / 94.69%
||
7 Day CHG-4.45%
Published-24 Dec, 2018 | 16:00
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Code Injection vulnerability exists in EVLink Parking, v3.2.0-12_v1 and earlier, which could enable access with maximum privileges when a remote code execution is performed.

Action-Not Available
Vendor-
Product-evlink_parkingevlink_parking_firmwareEVLink Parking v3.2.0-12_v1 and earlier
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2019-6816
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-9.1||CRITICAL
EPSS-0.44% / 62.30%
||
7 Day CHG~0.00%
Published-22 May, 2019 | 19:54
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Modicon Quantum all firmware versions, a CWE-94: Code Injection vulnerability could cause an unauthorized firmware modification with possible Denial of Service when using Modbus protocol.

Action-Not Available
Vendor-n/a
Product-modicon_quantummodicon_quantum_firmwareModicon Quantum - all firmware versions
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2021-22961
Matching Score-4
Assigner-HackerOne
ShareView Details
Matching Score-4
Assigner-HackerOne
CVSS Score-9.8||CRITICAL
EPSS-0.96% / 75.50%
||
7 Day CHG~0.00%
Published-18 Oct, 2021 | 12:48
Updated-03 Aug, 2024 | 18:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A code injection vulnerability exists within the firewall software of GlassWire v2.1.167 that could lead to arbitrary code execution from a file in the user path on first execution.

Action-Not Available
Vendor-glasswiren/a
Product-glasswireGlassWire
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2011-10018
Matching Score-4
Assigner-VulnCheck
ShareView Details
Matching Score-4
Assigner-VulnCheck
CVSS Score-10||CRITICAL
EPSS-0.51% / 65.57%
||
7 Day CHG~0.00%
Published-13 Aug, 2025 | 20:35
Updated-14 Aug, 2025 | 17:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
myBB 1.6.4 Backdoor Arbitrary Command Execution

myBB version 1.6.4 was distributed with an unauthorized backdoor embedded in the source code. The backdoor allowed remote attackers to execute arbitrary PHP code by injecting payloads into a specially crafted collapsed cookie. This vulnerability was introduced during packaging and was not part of the intended application logic. Exploitation requires no authentication and results in full compromise of the web server under the context of the web application.

Action-Not Available
Vendor-myBB GroupMyBB
Product-mybbForum Software
CWE ID-CWE-912
Hidden Functionality
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2016-10546
Matching Score-4
Assigner-HackerOne
ShareView Details
Matching Score-4
Assigner-HackerOne
CVSS Score-9.8||CRITICAL
EPSS-0.98% / 75.85%
||
7 Day CHG~0.00%
Published-31 May, 2018 | 20:00
Updated-16 Sep, 2024 | 17:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An arbitrary code injection vector was found in PouchDB 6.0.4 and lesser via the map/reduce functions used in PouchDB temporary views and design documents. The code execution engine for this branch is not properly sandboxed and may be used to run arbitrary JavaScript as well as system commands.

Action-Not Available
Vendor-pouchdbHackerOne
Product-pouchdbpouchdb node module
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2011-0364
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-10||HIGH
EPSS-15.54% / 94.42%
||
7 Day CHG~0.00%
Published-18 Feb, 2011 | 23:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The Management Console (webagent.exe) in Cisco Security Agent 5.1, 5.2, and 6.0 before 6.0.2.145 allows remote attackers to create arbitrary files and execute arbitrary code via unspecified parameters in a crafted st_upload request.

Action-Not Available
Vendor-n/aCisco Systems, Inc.
Product-security_agentn/a
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2024-12789
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.23% / 45.54%
||
7 Day CHG+0.05%
Published-19 Dec, 2024 | 16:31
Updated-10 Jan, 2025 | 21:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
PbootCMS IndexController.php code injection

A vulnerability was found in PbootCMS up to 3.2.3. It has been classified as critical. This affects an unknown part of the file apps/home/controller/IndexController.php. The manipulation of the argument tag leads to code injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. Upgrading to version 3.2.4 is able to address this issue. It is recommended to upgrade the affected component.

Action-Not Available
Vendor-pbootcmsn/a
Product-pbootcmsPbootCMS
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2021-22646
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-0.94% / 75.33%
||
7 Day CHG~0.00%
Published-28 Jul, 2022 | 14:19
Updated-17 Apr, 2025 | 16:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Ovarro TBox Code Injection

The “ipk” package containing the configuration created by TWinSoft can be uploaded, extracted, and executed in Ovarro TBox, allowing malicious code execution.

Action-Not Available
Vendor-ovarroOvarro
Product-tbox_ms-cpu32_firmwaretbox_ms-cpu32-s2_firmwaretbox_tg2tbox_lt2-530_firmwaretbox_lt2-532_firmwaretbox_lt2-540_firmwaretbox_rm2tbox_ms-cpu32-s2tbox_lt2-540tbox_lt2-532tbox_lt2-530tbox_ms-cpu32twinsofttbox_tg2_firmwaretbox_rm2_firmwareTBox
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2019-19502
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.85% / 74.02%
||
7 Day CHG~0.00%
Published-02 Dec, 2019 | 15:14
Updated-05 Aug, 2024 | 02:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Code injection in pluginconfig.php in Image Uploader and Browser for CKEditor before 4.1.9 allows remote authenticated users to execute arbitrary PHP code.

Action-Not Available
Vendor-maleckn/a
Product-image_uploader_and_browser_for_ckeditorn/a
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2024-12900
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.13% / 32.59%
||
7 Day CHG+0.01%
Published-23 Dec, 2024 | 01:31
Updated-15 Jul, 2025 | 20:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
FoxCMS Configuration File installdb.php code injection

A vulnerability classified as critical has been found in FoxCMS up to 1.2. Affected is an unknown function of the file /install/installdb.php of the component Configuration File Handler. The manipulation of the argument database password leads to code injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-qianfoxn/a
Product-foxcmsFoxCMS
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2024-13346
Matching Score-4
Assigner-Wordfence
ShareView Details
Matching Score-4
Assigner-Wordfence
CVSS Score-7.3||HIGH
EPSS-23.69% / 95.78%
||
7 Day CHG~0.00%
Published-13 Feb, 2025 | 06:58
Updated-24 Feb, 2025 | 17:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Avada Theme <= 7.11.13 - Unauthenticated Arbitrary Shortcode Execution

The Avada | Website Builder For WordPress & WooCommerce theme for WordPress is vulnerable to arbitrary shortcode execution in all versions up to, and including, 7.11.13. This is due to the software allowing users to execute an action that does not properly validate a value before running do_shortcode. This makes it possible for unauthenticated attackers to execute arbitrary shortcodes.

Action-Not Available
Vendor-Avada (ThemeFusion)
Product-avadaAvada | Website Builder For WordPress & WooCommerce
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2018-1999019
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-1.77% / 81.91%
||
7 Day CHG~0.00%
Published-23 Jul, 2018 | 15:00
Updated-16 Sep, 2024 | 19:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Chamilo LMS version 11.x contains an Unserialization vulnerability in the "hash" GET parameter for the api endpoint located at /webservices/api/v2.php that can result in Unauthenticated remote code execution. This attack appear to be exploitable via a simple GET request to the api endpoint. This vulnerability appears to have been fixed in After commit 0de84700648f098c1fbf6b807dee28ec640efe62.

Action-Not Available
Vendor-chamilon/a
Product-chamilo_lmsn/a
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2010-3085
Matching Score-4
Assigner-Red Hat, Inc.
ShareView Details
Matching Score-4
Assigner-Red Hat, Inc.
CVSS Score-10||HIGH
EPSS-0.85% / 74.03%
||
7 Day CHG~0.00%
Published-12 Oct, 2010 | 20:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The network-play implementation in Mednafen before 0.8.D might allow remote servers to execute arbitrary code via unspecified vectors, related to "stack manipulation" issues.

Action-Not Available
Vendor-david_shadoffn/a
Product-mednafenn/a
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2010-3761
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-10||HIGH
EPSS-9.23% / 92.40%
||
7 Day CHG~0.00%
Published-05 Oct, 2010 | 21:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Unspecified vulnerability in IBM Tivoli Storage Manager (TSM) FastBack 5.5.0.0 through 5.5.6.0 and 6.1.0.0 through 6.1.0.1 allows remote attackers to execute arbitrary code via unknown vectors, aka ZDI-CAN-700. NOTE: this might overlap CVE-2010-3058 or CVE-2010-3059.

Action-Not Available
Vendor-n/aIBM Corporation
Product-tivoli_storage_manager_fastbackn/a
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2019-17408
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-1.97% / 82.78%
||
7 Day CHG~0.00%
Published-14 Oct, 2019 | 11:43
Updated-05 Aug, 2024 | 01:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

parserIfLabel in inc/zzz_template.php in ZZZCMS zzzphp 1.7.3 allows remote attackers to execute arbitrary code because the danger_key function can be bypassed via manipulations such as strtr.

Action-Not Available
Vendor-zzzcmsn/a
Product-zzzphpn/a
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2020-8349
Matching Score-4
Assigner-Lenovo Group Ltd.
ShareView Details
Matching Score-4
Assigner-Lenovo Group Ltd.
CVSS Score-9.8||CRITICAL
EPSS-2.62% / 85.11%
||
7 Day CHG~0.00%
Published-14 Oct, 2020 | 21:25
Updated-04 Aug, 2024 | 09:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An internal security review has identified an unauthenticated remote code execution vulnerability in Cloud Networking Operating System (CNOS)’ optional REST API management interface. This interface is disabled by default and not vulnerable unless enabled. When enabled, it is only vulnerable where attached to a VRF and as allowed by defined ACLs. Lenovo strongly recommends upgrading to a non-vulnerable CNOS release. Where not possible, Lenovo recommends disabling the REST API management interface or restricting access to the management VRF and further limiting access to authorized management stations via ACL.

Action-Not Available
Vendor-Lenovo Group Limited
Product-rackswitch_ne1072trackswitch_ne2572rackswitch_ne1032rackswitch_g8296rackswitch_g8272cloud_networking_operating_systemrackswitch_ne0152trackswitch_ne10032rackswitch_g8332rackswitch_ne1032tCloud Networking Operating System (CNOS)
CWE ID-CWE-20
Improper Input Validation
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2010-3635
Matching Score-4
Assigner-Adobe Systems Incorporated
ShareView Details
Matching Score-4
Assigner-Adobe Systems Incorporated
CVSS Score-10||HIGH
EPSS-7.83% / 91.64%
||
7 Day CHG~0.00%
Published-10 Nov, 2010 | 01:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Adobe Flash Media Server (FMS) 3.0.x before 3.0.7, 3.5.x before 3.5.5, and 4.0.x before 4.0.1 allows attackers to execute arbitrary code via unspecified vectors, related to a "segmentation fault vulnerability."

Action-Not Available
Vendor-n/aAdobe Inc.
Product-flash_media_servern/a
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2010-2217
Matching Score-4
Assigner-Adobe Systems Incorporated
ShareView Details
Matching Score-4
Assigner-Adobe Systems Incorporated
CVSS Score-10||HIGH
EPSS-5.97% / 90.31%
||
7 Day CHG~0.00%
Published-11 Aug, 2010 | 18:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Adobe Flash Media Server (FMS) before 3.0.6, and 3.5.x before 3.5.4, allows attackers to execute arbitrary code via unspecified vectors, related to a "JS method vulnerability."

Action-Not Available
Vendor-n/aAdobe Inc.Microsoft CorporationLinux Kernel Organization, Inc
Product-linux_kernelflash_media_serverflash_media_server_2windowsn/a
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
  • Previous
  • 1
  • 2
  • 3
  • 4
  • ...
  • 20
  • 21
  • Next
Details not found