Version 1.3.0 of the Weave Cloud Agent Docker image contains a blank password for the root user. Systems deployed using affected versions of the Weave Cloud Agent container may allow a remote attacker to achieve root access with a blank password.
The official rabbitmq docker images before 3.7.13-beta.1-management-alpine (Alpine specific) contain a blank password for a root user. System using the rabbitmq docker container deployed by affected versions of the docker image may allow a remote attacker to achieve root access with a blank password.
The official vault docker images before 0.11.6 contain a blank password for a root user. System using the vault docker container deployed by affected versions of the docker image may allow a remote attacker to achieve root access with a blank password.
The official memcached docker images before 1.5.11-alpine (Alpine specific) contain a blank password for a root user. System using the memcached docker container deployed by affected versions of the docker image may allow a remote attacker to achieve root access with a blank password.
Version 1.0.0 of the Instana Dynamic APM Docker image contains a blank password for the root user. Systems deployed using affected versions of the Instana Dynamic APM container may allow a remote attacker to achieve root access with a blank password.
The official Crux Linux Docker images 3.0 through 3.4 contain a blank password for a root user. System using the Crux Linux Docker container deployed by affected versions of the Docker image may allow an attacker to achieve root access with a blank password.
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). A service available on port 10005/tcp of the affected devices could allow complete access to all services without authorization. An attacker could gain full control over an affected device, if he has access to this service. The system manual recommends to protect access to this port.
Triangle MicroWorks SCADA Data Gateway Missing Authentication Vulnerability. This vulnerability allows remote attackers to bypass authentication on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability. The specific flaw exists due to the lack of user authentication. The issue results from missing authentication in the default system configuration. An attacker can leverage this vulnerability to execute arbitrary code in the context of root. Was ZDI-CAN-20501.
The Micro Air Vehicle Link (MAVLink) protocol presents no authentication mechanism on its version 1.0 (nor authorization) whichs leads to a variety of attacks including identity spoofing, unauthorized access, PITM attacks and more. According to literature, version 2.0 optionally allows for package signing which mitigates this flaw. Another source mentions that MAVLink 2.0 only provides a simple authentication system based on HMAC. This implies that the flying system overall should add the same symmetric key into all devices of network. If not the case, this may cause a security issue, that if one of the devices and its symmetric key are compromised, the whole authentication system is not reliable.
MiR100, MiR200 and other MiR robots use the Robot Operating System (ROS) default packages exposing the computational graph without any sort of authentication. This allows attackers with access to the internal wireless and wired networks to take control of the robot seamlessly. In combination with CVE-2020-10269 and CVE-2020-10271, this flaw allows malicious actors to command the robot at desire.
The WPGraphQL 0.2.3 plugin for WordPress allows remote attackers to register a new user with admin privileges, whenever new user registrations are allowed. This is related to the registerUser mutation.
eQ-3 Homematic CCU2 prior to 2.47.10 and CCU3 prior to 3.47.10 JSON API has Improper Access Control for Interface.***Metadata related operations, resulting in the ability to read, set and deletion of Metadata.
On Netis WF2411 with firmware 2.1.36123 and other Netis WF2xxx devices (possibly WF2411 through WF2880), there is a stack-based buffer overflow that does not require authentication. This can cause denial of service (device restart) or remote code execution. This vulnerability can be triggered by a GET request with a long HTTP "Authorization: Basic" header that is mishandled by user_auth->user_ok in /bin/boa.
An issue was discovered on D-Link DIR-878 1.12B01 devices. Because strncpy is misused, there is a stack-based buffer overflow vulnerability that does not require authentication via the HNAP_AUTH HTTP header.
In NICE Engage through 6.5, the default configuration binds an unauthenticated JMX/RMI interface to all network interfaces, without restricting registration of MBeans, which allows remote attackers to execute arbitrary code via the RMI protocol by using the JMX connector. The observed affected TCP port is 6338 but, based on the product's configuration, a different one could be vulnerable.
A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The RCP+ network port allows access without authentication. Adding authentication feature to the respective library fixes the issue. The issue is classified as "CWE-284: Improper Access Control." This vulnerability, for example, allows a potential attacker to delete video or read video data.
An issue was discovered on Shenzhen Coship WM3300 WiFi Router 5.0.0.55 devices. The password reset functionality of the Wireless SSID doesn't require any type of authentication. By making a POST request to the regx/wireless/wl_security_2G.asp URI, the attacker can change the password of the Wi-FI network.
AVEVA Software, LLC InduSoft Web Studio prior to Version 8.1 SP3 and InTouch Edge HMI (formerly InTouch Machine Edition) prior to Version 2017 Update. Code is executed under the program runtime privileges, which could lead to the compromise of the machine.
An issue was discovered in Tyto Sahi Pro 6.x through 8.0.0. TestRunner_Non_distributed (and distributed end points) does not have any authentication mechanism. This allow an attacker to execute an arbitrary script on the remote Sahi Pro server. There is also a password-protected web interface intended for remote access to scripts. This web interface lacks server-side validation, which allows an attacker to create/modify/delete a script remotely without any password. Chaining both of these issues results in remote code execution on the Sahi Pro server.
A broken access control vulnerability found in Advan VD-1 firmware version 230 leads to insecure ADB service. An attacker can send a POST request to cgibin/AdbSetting.cgi to enable ADB without any authentication then take the compromised device as a relay or to install mining software.
An issue was discovered on D-Link DAP-1360 revision F devices. Remote attackers can start a telnet service without authorization via an undocumented HTTP request. Although this is the primary vulnerability, the impact depends on the firmware version. Versions 609EU through 613EUbeta were tested. Versions through 6.12b01 have weak root credentials, allowing an attacker to gain remote root access. After 6.12b01, the root credentials were changed but the telnet service can still be started without authorization.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of D-Link DCS-960L v1.07.102. Authentication is not required to exploit this vulnerability. The specific flaw exists within the HNAP service, which listens on TCP port 80 by default. When parsing the SOAPAction request header, the process does not properly validate the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the admin user. Was ZDI-CAN-8458.
Victure PC530 devices allow unauthenticated TELNET access as root.
The nd-restaurant-reservations plugin before 1.5 for WordPress has no requirement for nd_rst_import_settings_php_function authentication.
An issue was discovered in Zoho ManageEngine OpManager in builds before 14310. One can bypass the user password requirement and execute commands on the server. The "username+'@opm' string is used for the password. For example, if the username is admin, the password is admin@opm.
A broken access control vulnerability in Smart Battery A4, a multifunctional portable charger, firmware version ?<= r1.7.9 allows an attacker to get/reset administrator’s password without any authentication.
Directus 7 API before 2.2.2 has insufficient anti-automation, as demonstrated by lack of a CAPTCHA in core/Directus/Services/AuthService.php and endpoints/Auth.php.
Advantech WISE-PaaS/RMM, Versions 3.3.29 and prior. There is an unsecured function that allows anyone who can access the IP address to use the function without authentication.
In mintplex-labs/anything-llm v1.5.11 desktop version for Windows, the application opens server port 3001 on 0.0.0.0 with no authentication by default. This vulnerability allows an attacker to gain full backend access, enabling them to perform actions such as deleting all data from the workspace.
Super Micro SuperDoctor 5, when restrictions are not implemented in agent.cfg, allows remote attackers to execute arbitrary commands via NRPE.
In ONAP MSB through Dublin, by accessing an applicable port (30234, 30290, 32010, 30270, 30224, 30281, 30254, 30285, and/or 30271), an attacker gains full access to the respective ONAP services without any authentication. All ONAP Operations Manager (OOM) setups are affected.
An issue was discovered in upgrade_firmware.cgi on VStarcam 100T (C7824WIP) CH-sys-48.53.75.119~123 and 200V (C38S) CH-sys-48.53.203.119~123 devices. A remote command can be executed through a system firmware update without authentication. The attacker can modify the files within the internal firmware or even steal account information by executing a command.
Due to unencrypted and unauthenticated data communication, the wireless barcode scanner Inateck BCST-60 is prone to keystroke injection attacks. Thus, an attacker is able to send arbitrary keystrokes to a victim's computer system, e.g., to install malware when the target system is unattended. In this way, an attacker can remotely take control over the victim's computer that is operated with an affected receiver of this device.
RedwoodHQ 2.5.5 does not require any authentication for database operations, which allows remote attackers to create admin users via a con.automationframework users insert_one call.
An Incorrect Access Control vulnerability was found in Wikimedia MediaWiki 1.27.0 through 1.32.1. Directly POSTing to Special:ChangeEmail would allow for bypassing re-authentication, allowing for potential account takeover.
Improper Access Control in the RCP+ server of the Bosch Video Recording Manager (VRM) component allows arbitrary and unauthenticated access to a limited subset of certificates, stored in the underlying Microsoft Windows operating system. The fixed versions implement modified authentication checks. Prior releases of VRM software version 3.70 are considered unaffected. This vulnerability affects VRM v3.70.x, v3.71 < v3.71.0034 and v3.81 < 3.81.0050; DIVAR IP 5000 3.80 < 3.80.0039; BVMS all versions using VRM.
Anviz Global M3 Outdoor RFID Access Control executes any command received from any source. No authentication/encryption is done. Attackers can fully interact with the device: for example, send the "open door" command, download the users list (which includes RFID codes and passcodes in cleartext), or update/create users. The same attack can be executed on a local network and over the internet (if the device is exposed on a public IP address).
eQ-3 HomeMatic CCU2 devices before 2.41.8 and CCU3 devices before 3.43.15 use session IDs for authentication but lack authorization checks. An attacker can obtain a session ID via the user authentication dialogue, aka HMCCU-153. This leads to automatic login as admin.
The D-Link DIR-816 A2 1.11 router only checks the random token when authorizing a goform request. An attacker can get this token from dir_login.asp and use an API URL /goform/form2userconfig.cgi to edit the system account without authentication.
The D-Link DIR-816 A2 1.11 router only checks the random token when authorizing a goform request. An attacker can get this token from dir_login.asp and use an API URL /goform/setSysAdm to edit the web or system account without authentication.
eQ-3 HomeMatic CCU2 devices before 2.41.8 and CCU3 devices before 3.43.16 use session IDs for authentication but lack authorization checks. An attacker can obtain a session ID via an invalid login attempt to the RemoteApi account, aka HMCCU-154. This leads to automatic login as admin.
SAP Cloud Connector, before version 2.11.3, does not perform any authentication checks for functionalities that require user identity.
Under certain circumstances, SAP HANA Extended Application Services, advanced model (XS advanced) does not perform authentication checks properly for XS advanced platform and business users. Fixed in 1.0.97 to 1.0.99 (running on SAP HANA 1 or SAP HANA 2 SPS0 (second S stands for stack)).
eQ-3 AG HomeMatic CCU2 2.29.22 devices have an open XML-RPC port without authentication. This can be exploited by sending arbitrary XML-RPC requests to control the attached BidCos devices.
The default configuration in Apache Cassandra 3.8 through 3.11.1 binds an unauthenticated JMX/RMI interface to all network interfaces, which allows remote attackers to execute arbitrary Java code via an RMI request. This issue is a regression of CVE-2015-0225. The regression was introduced in https://issues.apache.org/jira/browse/CASSANDRA-12109. The fix for the regression is implemented in https://issues.apache.org/jira/browse/CASSANDRA-14173. This fix is contained in the 3.11.2 release of Apache Cassandra.
In Schneider Electric Evlink Charging Station versions prior to v3.2.0-12_v1, the Web Interface has an issue that may allow a remote attacker to gain administrative privileges without properly authenticating remote users.
A missing authentication for appliance registration vulnerability in Trend Micro Email Encryption Gateway 5.5 could allow an attacker to manipulate the registration process of the product to reset configuration parameters.
The TP-LINK EAP Controller is TP-LINK's software for remotely controlling wireless access point devices. It utilizes a Java remote method invocation (RMI) service for remote control. The RMI interface does not require any authentication before use, so it lacks user authentication for RMI service commands in EAP controller versions 2.5.3 and earlier. Remote attackers can implement deserialization attacks through the RMI protocol. Successful attacks may allow a remote attacker to remotely control the target server and execute Java functions or bytecode.
An issue was discovered in Zoho ManageEngine Desktop Central 10.0.124 and 10.0.184: missing authentication/authorization for a database query mechanism.
An issue was discovered in Zoho ManageEngine Desktop Central 10.0.124 and 10.0.184: insufficient enforcement of database query type restrictions.