Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2020-10580

Summary
Assigner-mitre
Assigner Org ID-8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At-25 Mar, 2021 | 19:48
Updated At-04 Aug, 2024 | 11:06
Rejected At-
Credits

A command injection on the /admin/broadcast.php script of Invigo Automatic Device Management (ADM) through 5.0 allows remote authenticated attackers to execute arbitrary PHP code on the server as the user running the application.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:mitre
Assigner Org ID:8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At:25 Mar, 2021 | 19:48
Updated At:04 Aug, 2024 | 11:06
Rejected At:
▼CVE Numbering Authority (CNA)

A command injection on the /admin/broadcast.php script of Invigo Automatic Device Management (ADM) through 5.0 allows remote authenticated attackers to execute arbitrary PHP code on the server as the user running the application.

Affected Products
Vendor
n/a
Product
n/a
Versions
Affected
  • n/a
Problem Types
TypeCWE IDDescription
textN/An/a
Type: text
CWE ID: N/A
Description: n/a
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.on-x.com/sites/default/files/security_advisory_-_multiple_vulnerabilities_-_invigo_adm.pdf
x_refsource_CONFIRM
https://cwe.mitre.org/data/definitions/77.html
x_refsource_MISC
Hyperlink: https://www.on-x.com/sites/default/files/security_advisory_-_multiple_vulnerabilities_-_invigo_adm.pdf
Resource:
x_refsource_CONFIRM
Hyperlink: https://cwe.mitre.org/data/definitions/77.html
Resource:
x_refsource_MISC
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.on-x.com/sites/default/files/security_advisory_-_multiple_vulnerabilities_-_invigo_adm.pdf
x_refsource_CONFIRM
x_transferred
https://cwe.mitre.org/data/definitions/77.html
x_refsource_MISC
x_transferred
Hyperlink: https://www.on-x.com/sites/default/files/security_advisory_-_multiple_vulnerabilities_-_invigo_adm.pdf
Resource:
x_refsource_CONFIRM
x_transferred
Hyperlink: https://cwe.mitre.org/data/definitions/77.html
Resource:
x_refsource_MISC
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cve@mitre.org
Published At:25 Mar, 2021 | 20:15
Updated At:05 Oct, 2022 | 16:40

A command injection on the /admin/broadcast.php script of Invigo Automatic Device Management (ADM) through 5.0 allows remote authenticated attackers to execute arbitrary PHP code on the server as the user running the application.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Primary2.06.5MEDIUM
AV:N/AC:L/Au:S/C:P/I:P/A:P
Type: Primary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 2.0
Base score: 6.5
Base severity: MEDIUM
Vector:
AV:N/AC:L/Au:S/C:P/I:P/A:P
CPE Matches

invigo
invigo
>>automatic_device_management>>Versions up to 5.0(inclusive)
cpe:2.3:a:invigo:automatic_device_management:*:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-77Primarynvd@nist.gov
CWE ID: CWE-77
Type: Primary
Source: nvd@nist.gov
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://cwe.mitre.org/data/definitions/77.htmlcve@mitre.org
Third Party Advisory
https://www.on-x.com/sites/default/files/security_advisory_-_multiple_vulnerabilities_-_invigo_adm.pdfcve@mitre.org
Exploit
Third Party Advisory
Hyperlink: https://cwe.mitre.org/data/definitions/77.html
Source: cve@mitre.org
Resource:
Third Party Advisory
Hyperlink: https://www.on-x.com/sites/default/files/security_advisory_-_multiple_vulnerabilities_-_invigo_adm.pdf
Source: cve@mitre.org
Resource:
Exploit
Third Party Advisory

Change History

0
Information is not available yet

Similar CVEs

708Records found

CVE-2025-9090
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-2.52% / 85.16%
||
7 Day CHG~0.00%
Published-17 Aug, 2025 | 02:02
Updated-21 Aug, 2025 | 16:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC20 Telnet Service telnet websFormDefine command injection

A vulnerability was identified in Tenda AC20 16.03.08.12. Affected is the function websFormDefine of the file /goform/telnet of the component Telnet Service. The manipulation leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac20ac20_firmwareAC20
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-8818
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.24% / 46.48%
||
7 Day CHG~0.00%
Published-10 Aug, 2025 | 22:32
Updated-04 Sep, 2025 | 18:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 setLan setDFSSetting os command injection

A vulnerability has been found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. Affected by this issue is the function setDFSSetting of the file /goform/setLan. The manipulation of the argument lanNetmask/lanIp leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6350_firmwarere6300_firmwarere6500re9000re9000_firmwarere6350re6250re6300re6250_firmwarere7000_firmwarere6500_firmwarere7000RE6300RE6350RE7000RE9000RE6500RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-9583
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.18% / 38.94%
||
7 Day CHG~0.00%
Published-28 Aug, 2025 | 20:02
Updated-02 Oct, 2025 | 19:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Comfast CF-N1 webmgnt ping_config command injection

A vulnerability has been found in Comfast CF-N1 2.6.0. Affected by this vulnerability is the function ping_config of the file /usr/bin/webmgnt. The manipulation leads to command injection. Remote exploitation of the attack is possible. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-comfastComfast
Product-cf-n1_firmwarecf-n1CF-N1
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-9161
Matching Score-4
Assigner-Rockwell Automation
ShareView Details
Matching Score-4
Assigner-Rockwell Automation
CVSS Score-7.3||HIGH
EPSS-0.08% / 23.04%
||
7 Day CHG~0.00%
Published-09 Sep, 2025 | 12:57
Updated-20 Oct, 2025 | 19:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Rockwell Automation FactoryTalk Optix Remote Code Execution Vulnerability

A security issue exists within FactoryTalk Optix MQTT broker due to the lack of URI sanitization. This flaw enables the loading of remote Mosquito plugins, which can be used to achieve remote code execution.

Action-Not Available
Vendor-Rockwell Automation, Inc.
Product-factorytalk_optixFactoryTalk Optix
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-9223
Matching Score-4
Assigner-Zohocorp
ShareView Details
Matching Score-4
Assigner-Zohocorp
CVSS Score-8.8||HIGH
EPSS-1.28% / 79.30%
||
7 Day CHG-0.13%
Published-11 Nov, 2025 | 13:13
Updated-26 Feb, 2026 | 16:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Command Injection

Zohocorp ManageEngine Applications Manager versions 178100 and below are vulnerable to authenticated command injection vulnerability due to the improper configuration in the execute program action feature.

Action-Not Available
Vendor-Zoho Corporation Pvt. Ltd.
Product-ManageEngine Applications Manager
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-8825
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.24% / 46.48%
||
7 Day CHG~0.00%
Published-11 Aug, 2025 | 02:02
Updated-04 Sep, 2025 | 18:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 RP_setBasicAuto os command injection

A vulnerability was identified in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. This affects the function RP_setBasicAuto of the file /goform/RP_setBasicAuto. The manipulation of the argument staticIp/staticNetmask leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6350_firmwarere6300_firmwarere6500re9000re9000_firmwarere6350re6250re6300re6250_firmwarere7000_firmwarere6500_firmwarere7000RE6300RE6350RE7000RE9000RE6500RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-9582
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.19% / 41.04%
||
7 Day CHG~0.00%
Published-28 Aug, 2025 | 19:32
Updated-11 Sep, 2025 | 13:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Comfast CF-N1 webmgnt ntp_timezone command injection

A flaw has been found in Comfast CF-N1 2.6.0. Affected is the function ntp_timezone of the file /usr/bin/webmgnt. Executing manipulation of the argument timestr can lead to command injection. The attack may be launched remotely. The exploit has been published and may be used.

Action-Not Available
Vendor-comfastComfast
Product-cf-n1cf-n1_firmwareCF-N1
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-9580
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.20% / 42.40%
||
7 Day CHG~0.00%
Published-28 Aug, 2025 | 19:02
Updated-12 Sep, 2025 | 16:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
LB-LINK BL-X26 HTTP set_blacklist os command injection

A security vulnerability has been detected in LB-LINK BL-X26 1.2.8. This affects an unknown function of the file /goform/set_blacklist of the component HTTP Handler. Such manipulation of the argument mac leads to os command injection. The attack can be launched remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-lb-linkLB-LINK
Product-bl-x26bl-x26_firmwareBL-X26
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-9581
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.21% / 43.17%
||
7 Day CHG~0.00%
Published-28 Aug, 2025 | 19:02
Updated-11 Sep, 2025 | 13:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Comfast CF-N1 webmgnt multi_pppoe command injection

A vulnerability was detected in Comfast CF-N1 2.6.0. This impacts the function multi_pppoe of the file /usr/bin/webmgnt. Performing manipulation of the argument phy_interface results in command injection. The attack may be initiated remotely. The exploit is now public and may be used.

Action-Not Available
Vendor-comfastComfast
Product-cf-n1cf-n1_firmwareCF-N1
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-8937
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.54% / 67.31%
||
7 Day CHG~0.00%
Published-14 Aug, 2025 | 04:32
Updated-03 Oct, 2025 | 18:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK N350R formSysCmd command injection

A vulnerability has been found in TOTOLINK N350R 1.2.3-B20130826. This vulnerability affects unknown code of the file /boafrm/formSysCmd. The manipulation leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-n350r_firmwaren350rN350R
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-8828
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.24% / 46.48%
||
7 Day CHG~0.00%
Published-11 Aug, 2025 | 03:32
Updated-04 Sep, 2025 | 18:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 setIpv6 ipv6cmd os command injection

A vulnerability was determined in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. Affected is the function ipv6cmd of the file /goform/setIpv6. The manipulation of the argument Ipv6PriDns/Ipv6SecDns/Ipv6StaticGateway/LanIpv6Addr/LanPrefixLen/pppoeUser/pppoePass/pppoeIdleTime/pppoeRedialPeriod/Ipv6in4_PrefixLen/LocalIpv6/RemoteIpv4/LanIPv6_Prefix/LanPrefixLen/ipv6to4Relay/ipv6rdRelay/tunrd_PrefixLen/wan_UseLinkLocal/Ipv6StaticIp/Ipv6PrefixLen leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6350_firmwarere6300_firmwarere6500re9000re9000_firmwarere6350re6250re6300re6250_firmwarere7000_firmwarere6500_firmwarere7000RE6300RE6350RE7000RE9000RE6500RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-9244
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.30% / 53.11%
||
7 Day CHG~0.00%
Published-20 Aug, 2025 | 19:32
Updated-02 Sep, 2025 | 18:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 addStaticRoute os command injection

A security vulnerability has been detected in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This vulnerability affects the function addStaticRoute of the file /goform/addStaticRoute. Such manipulation of the argument staticRoute_IP_setting/staticRoute_Netmask_setting/staticRoute_Gateway_setting/staticRoute_Metric_setting/staticRoute_destType_setting leads to os command injection. The attack may be launched remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6300re9000_firmwarere6350re6500re6250_firmwarere7000re7000_firmwarere6250re6350_firmwarere9000re6300_firmwarere6500_firmwareRE7000RE9000RE6250RE6350RE6300RE6500
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-9387
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.24% / 46.60%
||
7 Day CHG~0.00%
Published-24 Aug, 2025 | 12:02
Updated-12 Sep, 2025 | 18:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
DCN DCME-720 Web Management Backend ip_block.php os command injection

A vulnerability was found in DCN DCME-720 9.1.5.11. This affects an unknown function of the file /usr/local/www/function/audit/newstatistics/ip_block.php of the component Web Management Backend. Performing manipulation of the argument ip results in os command injection. It is possible to initiate the attack remotely. The exploit has been made public and could be used. Other products might be affected as well. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-dcnetworksDCN
Product-dcme-720_firmwaredcme-720DCME-720
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-8829
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.24% / 46.48%
||
7 Day CHG~0.00%
Published-11 Aug, 2025 | 04:02
Updated-04 Sep, 2025 | 18:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 RP_setBasicAuto um_red os command injection

A vulnerability was identified in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. Affected by this vulnerability is the function um_red of the file /goform/RP_setBasicAuto. The manipulation of the argument hname leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6350_firmwarere6300_firmwarere6500re9000re9000_firmwarere6350re6250re6300re6250_firmwarere7000_firmwarere6500_firmwarere7000RE6300RE6350RE7000RE9000RE6500RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2026-2534
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.35% / 57.09%
||
7 Day CHG+0.09%
Published-16 Feb, 2026 | 04:02
Updated-23 Feb, 2026 | 10:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Comfast CF-N1 V2 mbox-config sub_44AC4C command injection

A vulnerability has been found in Comfast CF-N1 V2 2.6.0.2. The affected element is the function sub_44AC4C of the file /cgi-bin/mbox-config?method=SET&section=ptest_bandwidth. The manipulation of the argument bandwidth leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-comfastComfast
Product-cf-n1cf-n1_firmwareCF-N1 V2
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-9579
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.20% / 42.40%
||
7 Day CHG~0.00%
Published-28 Aug, 2025 | 18:32
Updated-11 Sep, 2025 | 13:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
LB-LINK BL-X26 HTTP set_hidessid_cfg os command injection

A weakness has been identified in LB-LINK BL-X26 1.2.8. The impacted element is an unknown function of the file /goform/set_hidessid_cfg of the component HTTP Handler. This manipulation of the argument enable causes os command injection. The attack can be initiated remotely. The exploit has been made available to the public and could be exploited. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-b-linkLB-LINK
Product-bl-x26bl-x26_firmwareBL-X26
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-9584
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.18% / 38.94%
||
7 Day CHG~0.00%
Published-Not Available
Updated-02 Oct, 2025 | 19:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability was found in Comfast CF-N1 2.6.0. Affected by this issue is the function update_interface_png of the file /usr/bin/webmgnt. The manipulation of the argument interface/display_name results in command injection. The attack can be executed remotely. The exploit has been made public and could be used.

Action-Not Available
Vendor-comfast
Product-cf-n1_firmwarecf-n1
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-8956
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.07% / 22.30%
||
7 Day CHG~0.00%
Published-14 Aug, 2025 | 10:02
Updated-18 Aug, 2025 | 15:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR‑818L ssdpcgi cgibin getenv command injection

A vulnerability was found in D-Link DIR‑818L up to 1.05B01. This issue affects the function getenv of the file /htdocs/cgibin of the component ssdpcgi. The manipulation leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-818l_firmwaredir-818lDIR‑818L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-9149
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.30% / 53.20%
||
7 Day CHG~0.00%
Published-19 Aug, 2025 | 17:32
Updated-06 Oct, 2025 | 18:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Wavlink WL-NU516U1 wireless.cgi sub_4032E4 command injection

A vulnerability was determined in Wavlink WL-NU516U1 M16U1_V240425. This impacts the function sub_4032E4 of the file /cgi-bin/wireless.cgi. This manipulation of the argument Guest_ssid causes command injection. The attack is possible to be carried out remotely. The exploit has been publicly disclosed and may be utilized.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wl-nu516u1_firmwarewl-nu516u1WL-NU516U1
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-8823
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.24% / 46.48%
||
7 Day CHG~0.00%
Published-11 Aug, 2025 | 01:05
Updated-04 Sep, 2025 | 18:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 setDeviceName os command injection

A vulnerability was found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. Affected by this vulnerability is the function setDeviceName of the file /goform/setDeviceName. The manipulation of the argument DeviceName leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6350_firmwarere6300_firmwarere6500re9000re9000_firmwarere6350re6250re6300re6250_firmwarere7000_firmwarere6500_firmwarere7000RE6300RE6350RE7000RE9000RE6500RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-8827
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.24% / 46.48%
||
7 Day CHG~0.00%
Published-11 Aug, 2025 | 03:02
Updated-04 Sep, 2025 | 18:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 RP_setBasicAuto um_inspect_cross_band os command injection

A vulnerability was found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. This issue affects the function um_inspect_cross_band of the file /goform/RP_setBasicAuto. The manipulation of the argument staticGateway leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6350_firmwarere6300_firmwarere6500re9000re9000_firmwarere6350re6250re6300re6250_firmwarere7000_firmwarere6500_firmwarere7000RE6300RE6350RE7000RE9000RE6500RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-9575
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.24% / 46.48%
||
7 Day CHG~0.00%
Published-28 Aug, 2025 | 18:02
Updated-04 Sep, 2025 | 18:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 upload.cgi cgiMain os command injection

A vulnerability was determined in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This issue affects the function cgiMain of the file /cgi-bin/upload.cgi. Executing manipulation of the argument filename can lead to os command injection. The attack may be performed from a remote location. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6350_firmwarere6300_firmwarere6500re9000re9000_firmwarere6350re6250re6300re6250_firmwarere7000_firmwarere6500_firmwarere7000RE6300RE6350RE6500RE9000RE7000RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-9586
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.18% / 38.94%
||
7 Day CHG~0.00%
Published-28 Aug, 2025 | 21:02
Updated-02 Oct, 2025 | 19:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Comfast CF-N1 webmgnt wireless_device_dissoc command injection

A vulnerability was identified in Comfast CF-N1 2.6.0. This vulnerability affects the function wireless_device_dissoc of the file /usr/bin/webmgnt. Such manipulation of the argument mac leads to command injection. The attack may be performed from a remote location. The exploit is publicly available and might be used.

Action-Not Available
Vendor-comfastComfast
Product-cf-n1_firmwarecf-n1CF-N1
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-2535
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.35% / 57.09%
||
7 Day CHG+0.09%
Published-16 Feb, 2026 | 04:32
Updated-23 Feb, 2026 | 10:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Comfast CF-N1 V2 mbox-config sub_44AB9C command injection

A vulnerability was found in Comfast CF-N1 V2 2.6.0.2. The impacted element is the function sub_44AB9C of the file /cgi-bin/mbox-config?method=SET&section=ptest_channel. The manipulation of the argument channel results in command injection. The attack can be launched remotely. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-comfastComfast
Product-cf-n1cf-n1_firmwareCF-N1 V2
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-7952
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.66% / 81.78%
||
7 Day CHG-0.12%
Published-22 Jul, 2025 | 03:02
Updated-23 Jul, 2025 | 16:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK T6 MQTT Packet wireless.so ckeckKeepAlive command injection

A vulnerability classified as critical was found in TOTOLINK T6 4.1.5cu.748. This vulnerability affects the function ckeckKeepAlive of the file wireless.so of the component MQTT Packet Handler. The manipulation leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-t6_firmwaret6T6
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-8665
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.56% / 67.84%
||
7 Day CHG~0.00%
Published-06 Aug, 2025 | 17:02
Updated-06 Aug, 2025 | 20:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
agno-agi agno Model Context Protocol mcp.py MultiMCPTools os command injection

A vulnerability, which was classified as critical, has been found in agno-agi agno up to 1.7.5. This issue affects the function MCPTools/MultiMCPTools in the library libs/agno/agno/tools/mcp.py of the component Model Context Protocol Handler. The manipulation of the argument command leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-agno-agi
Product-agno
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2026-2548
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.41% / 80.23%
||
7 Day CHG+0.35%
Published-16 Feb, 2026 | 09:02
Updated-23 Feb, 2026 | 10:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
WAYOS FBM-220G rc sub_40F820 command injection

A flaw has been found in WAYOS FBM-220G 24.10.19. This affects the function sub_40F820 of the file rc. Executing a manipulation of the argument upnp_waniface/upnp_ssdp_interval/upnp_max_age can lead to command injection. The attack can be executed remotely. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-WAYOS
Product-FBM-220G
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-31996
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-1.36% / 79.91%
||
7 Day CHG~0.00%
Published-23 May, 2023 | 00:00
Updated-17 Jan, 2025 | 17:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Hanwha IP Camera ANE-L7012R 1.41.01 is vulnerable to Command Injection due to improper sanitization of special characters for the NAS storage test function.

Action-Not Available
Vendor-hanwhavisionn/a
Product-qno-8030rqno-6022rqnd-6030rqnp-6250h_firmwareqnd-6020rqnv-7032rqne-7080rvwqnv-8010rqnd-6082rpnm-9085rqz_firmwareqno-8080r_firmwareqnd-7030r_firmwareane-l7012rqnd-8010rqnp-6320rqnd-6030r_firmwarepnm-9084rqz1qnp-6250qnd-7032r_firmwareqnp-6320hspnm-9000vdane-l6012r_firmwarepnm-9322vqp_firmwareano-l6082rqnv-6082r1pnm-9000vd_firmwarepnm-8082vtqnd-6012r_firmwarepnm-9085rqz1qnv-7012r_firmwareqno-6070r_firmwareqnv-6030r_firmwareqnv-6032rqno-7020rqnv-7020r_firmwareqnd-6082r_firmwareqnv-6070r_firmwareqnf-8010qnp-6230qnv-6012r1qnd-8021_firmwareqnd-7032rqnd-6021_firmwareqno-7012r_firmwareqnp-6230rh_firmwareqno-6012rqnp-6230_firmwareqnd-7082r_firmwareqnp-6320pnm-7002vd_firmwareqno-6032rqnd-6011qno-7022r_firmwareqne-7088rv_firmwareqnp-6250hano-l6082r_firmwareqnv-8080rqnd-7080r_firmwareqnv-7010rqnd-6082r1qnd-7022rqnv-6012r1_firmwareqno-7080rpnm-9031rvqne-7088rvpnm-7002vdpnm-c9022rvanv-l6023r_firmwareqnp-6250_firmwareqnd-6082r1_firmwareqno-6070rpnm-9085rqzano-l6022rqnv-6070rano-l6022r_firmwareqnv-6022r1_firmwareqnd-8030rqnv-6022r1qnv-7082ranv-l7082r_firmwarepnm-8082vt_firmwareqnd-70142rqno-6032r_firmwareqnp-6320hqnd-6010r_firmwareqno-7022rpnm-9002vq_firmwareanv-l7012rano-l6012rqnd-8011pnm-9084rqz1_firmwareqnd-7010r_firmwareqnp-6250rane-l7012r_firmwareqnf-8010_firmwarepnm-9000qbqnv-6030rqno-6030rpnm-12082rvdpnm-9031rv_firmwareanv-l6012r_firmwareqnd-7010rqno-7082rpnm-9085rqz1_firmwareqno-7032ranv-l6023rpnm-c7083rvd_firmwarepnm-9002vqpnm-9022vqno-8020rqnd-7020rqno-8020r_firmwareqno-8080rano-l6012r_firmwareqno-7080r_firmwareqnd-70142r_firmwareqnv-7012rqno-6020rqnd-6022rpnm-12082rvd_firmwareano-l7022rqnv-6010r_firmwareqnv-7022rpnm-9000qb_firmwareqnd-6012r1_firmwareqnd-8080r_firmwareqnv-8020r_firmwareqno-6012r1_firmwareqnp-6230h_firmwareqne-7080rvw_firmwareqno-6010r_firmwareqno-6010rano-l7012r_firmwareqno-6020r_firmwareqnd-6012rano-l7012rqno-7020r_firmwareqne-8011rqno-7030r_firmwareqno-6012r_firmwareqnf-9010anv-l6012rpnm-c7083rvdqnp-6320h_firmwareqnv-7032r_firmwareqnd-7080rqne-8021r_firmwareqnv-7082r_firmwarepnm-9084rqz_firmwareqno-6022r1_firmwareqnv-8080r_firmwareqnd-8020r_firmwarepnm-9084qz1qnv-7022r_firmwareano-l7082rqnv-6082r1_firmwareanv-l7082rqnd-6032r_firmwareqno-8010ranv-l6082rpnm-9084qz1_firmwareqno-7082r_firmwareqnp-6320r_firmwareqnv-6082rpnm-c12083rvd_firmwareqno-6030r_firmwareqne-8021rqnv-7030r_firmwareqno-6022r1qnd-6010rqnd-7020r_firmwareqno-6082r1_firmwarepnm-7082rvd_firmwarepnm-9322vqpqnv-6032r_firmwareano-l7082r_firmwareqnv-6022r_firmwarepnm-7082rvdanv-l6082r_firmwareqne-8011r_firmwareqno-6012r1qnd-8020rpnm-c12083rvdqno-6022r_firmwareqnv-6012r_firmwareqnd-6032rqno-7012rpnm-c9022rv_firmwareqnv-8030r_firmwareqnd-6070r_firmwareqno-7030rpnm-9084rqzqnv-7030rqnd-7082rqnd-8011_firmwareqnv-6020r_firmwareqnv-7010r_firmwareqnp-6320_firmwarepnm-9022v_firmwareqnv-7020rqnd-6021qno-8030r_firmwareqnf-9010_firmwareqno-6082r_firmwareqnd-6070rqnp-6230rhqno-8010r_firmwareqnv-8020rqno-7032r_firmwareqnp-6250r_firmwareqnv-6010rqnd-8010r_firmwareqnd-8030r_firmwareqnv-8030rqnd-6020r_firmwareqnd-6022r_firmwareano-l7022r_firmwareqnd-8021qnv-6082r_firmwareqnp-6320hs_firmwareqnd-8080rqnd-6012r1anv-l7012r_firmwareqnv-6020rqnv-6022rqnv-7080rqnv-6012rqnd-7030rqnv-8010r_firmwareqno-6082r1ane-l6012rqno-6082rqnd-6011_firmwareqnp-6230hqnv-7080r_firmwareqnd-7022r_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-8697
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.56% / 67.84%
||
7 Day CHG~0.00%
Published-07 Aug, 2025 | 19:02
Updated-07 Aug, 2025 | 21:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
agentUniverse MCPSessionManager/MCPTool/MCPToolkit StdioServerParameters os command injection

A vulnerability was found in agentUniverse up to 0.0.18 and classified as critical. This issue affects the function StdioServerParameters of the component MCPSessionManager/MCPTool/MCPToolkit. The manipulation leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-n/a
Product-agentUniverse
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-7932
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.08% / 23.67%
||
7 Day CHG-0.01%
Published-21 Jul, 2025 | 17:02
Updated-03 Oct, 2025 | 18:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR‑817L ssdpcgi lxmldbc_system command injection

A vulnerability classified as critical has been found in D-Link DIR‑817L up to 1.04B01. This affects the function lxmldbc_system of the file ssdpcgi. The manipulation leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-817ldir-817l_firmwareDIR‑817L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-8244
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.93% / 75.77%
||
7 Day CHG~0.00%
Published-27 Jul, 2025 | 22:02
Updated-29 Jul, 2025 | 21:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK X15 HTTP POST Request formMapDelDevice buffer overflow

A vulnerability was found in TOTOLINK X15 1.0.0-B20230714.1105. It has been classified as critical. Affected is an unknown function of the file /boafrm/formMapDelDevice of the component HTTP POST Request Handler. The manipulation of the argument macstr leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-x15_firmwarex15X15
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-7788
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.17% / 38.29%
||
7 Day CHG~0.00%
Published-18 Jul, 2025 | 15:02
Updated-11 Sep, 2025 | 19:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Xuxueli xxl-job SampleXxlJob.java commandJobHandler os command injection

A vulnerability has been found in Xuxueli xxl-job up to 3.1.1 and classified as critical. Affected by this vulnerability is the function commandJobHandler of the file src\main\java\com\xxl\job\executor\service\jobhandler\SampleXxlJob.java. The manipulation leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-xuxueliXuxueli
Product-xxl-jobxxl-job
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-8667
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.56% / 67.84%
||
7 Day CHG~0.00%
Published-06 Aug, 2025 | 18:02
Updated-06 Aug, 2025 | 20:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
SkyworkAI DeepResearchAgent tools.py from_mcp os command injection

A vulnerability, which was classified as critical, was found in SkyworkAI DeepResearchAgent up to 08eb7f8eb9505d0094d75bb97ff7dacc3fa3bbf2. Affected is the function from_code/from_dict/from_mcp of the file src/tools/tools.py. The manipulation leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. Continious delivery with rolling releases is used by this product. Therefore, no version details of affected nor updated releases are available. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-SkyworkAI
Product-DeepResearchAgent
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-45596
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.4||HIGH
EPSS-1.43% / 80.39%
||
7 Day CHG~0.00%
Published-26 Dec, 2021 | 00:39
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-rbs850rbk752_firmwarerbk752rbs750_firmwarerbr750rbs750cbr750rbs850_firmwarerbr850rbk852_firmwarerbr750_firmwarerbk852cbr750_firmwarerbr850_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45595
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.6||HIGH
EPSS-0.24% / 46.61%
||
7 Day CHG~0.00%
Published-26 Dec, 2021 | 00:41
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an authenticated user. This affects LBR20 before 2.6.3.50, RBS50Y before 2.7.3.22, RBR10 before 2.7.3.22, RBR20 before 2.7.3.22, RBR40 before 2.7.3.22, RBR50 before 2.7.3.22, RBS10 before 2.7.3.22, RBS20 before 2.7.3.22, RBS40 before 2.7.3.22, RBS50 before 2.7.3.22, RBK12 before 2.7.3.22, RBK20 before 2.7.3.22, RBK40 before 2.7.3.22, and RBK50 before 2.7.3.22.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-rbs40rbs50y_firmwarerbk12rbs40_firmwarerbk20rbr10_firmwarerbr10rbs10_firmwarerbr40_firmwarerbs20_firmwarerbs50_firmwarerbs20rbr40rbs50yrbs50rbr50_firmwarerbk40rbr20rbr50lbr20rbs10rbr20_firmwarerbk50rbk40_firmwarelbr20_firmwarerbk50_firmwarerbk20_firmwarerbk12_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45556
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-0.79% / 73.59%
||
7 Day CHG~0.00%
Published-26 Dec, 2021 | 00:50
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an authenticated user. This affects GS108Tv2 before 5.4.2.36, GS110TPP before 7.0.7.2, GS110TPv2 before 5.4.2.36., GS110TPv3 before 7.0.7.2, GS308T before 1.0.3.2, GS310TP before 1.0.3.2, GS724TPP before 2.0.6.3, GS724TPv2 before 2.0.6.3, GS728TPPv2 before 6.0.8.2, GS728TPv2 before 6.0.8.2, GS752TPP before 6.0.8.2, GS752TPv2 before 6.0.8.2, MS510TXM before 1.0.4.2, and MS510TXUP before 1.0.4.2.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-gs728tppv2gs308tgs310tp_firmwaregs308t_firmwaregs110tpv3_firmwaregs110tppgs108tv2_firmwaregs724tpp_firmwaregs728tpv2_firmwaregs752tpv2_firmwarems510txup_firmwaregs110tpv2_firmwaregs752tppms510txupgs108tv2gs752tpv2gs752tpp_firmwarems510txm_firmwaregs724tpv2ms510txmgs724tpv2_firmwaregs110tpv2gs110tpp_firmwaregs110tpv3gs728tppv2_firmwaregs724tppgs728tpv2gs310tpn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-7414
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.62% / 69.81%
||
7 Day CHG+0.26%
Published-10 Jul, 2025 | 20:32
Updated-16 Jul, 2025 | 15:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O3V2 httpd setPingInfo fromNetToolGet os command injection

A vulnerability classified as critical was found in Tenda O3V2 1.0.0.12(3880). This vulnerability affects the function fromNetToolGet of the file /goform/setPingInfo of the component httpd. The manipulation of the argument domain leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o3_firmwareo3O3V2
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-45598
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.4||HIGH
EPSS-0.98% / 76.44%
||
7 Day CHG~0.00%
Published-26 Dec, 2021 | 00:39
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-cbr40rbs850cbr40_firmwarecbr750rbs850_firmwarerbr850rbk852_firmwarerbk852cbr750_firmwarerbr850_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45531
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.1||HIGH
EPSS-0.94% / 75.91%
||
7 Day CHG~0.00%
Published-26 Dec, 2021 | 00:57
Updated-04 Aug, 2024 | 04:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

NETGEAR D6220 devices before 1.0.0.76 are affected by command injection by an authenticated user.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-d6220d6220_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45541
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.4||HIGH
EPSS-1.88% / 82.89%
||
7 Day CHG~0.00%
Published-26 Dec, 2021 | 00:53
Updated-04 Aug, 2024 | 04:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7900 before 1.0.4.38, R7900P before 1.4.2.84, R8000 before 1.0.4.68, R8000P before 1.4.2.84, RAX200 before 1.0.3.106, MR60 before 1.0.6.110, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, MS60 before 1.0.6.110, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-rax80rax75r8000r7900r8000prax50rbs850rax45ms60_firmwarerbr750r8000_firmwarer8000p_firmwarerax200r7900prax200_firmwarerbs750_firmwaremr60mr60_firmwarerbs850_firmwarerbr850rax80_firmwarerbr750_firmwarerbk752_firmwarer7900_firmwarerbk752rbs750rax75_firmwarerax50_firmwarerax45_firmwarerbk852_firmwarerbk852r7900p_firmwarems60rbr850_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-7615
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.64% / 81.66%
||
7 Day CHG+0.68%
Published-14 Jul, 2025 | 15:14
Updated-15 Jul, 2025 | 13:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK T6 HTTP POST Request cstecgi.cgi clearPairCfg command injection

A vulnerability classified as critical was found in TOTOLINK T6 4.1.5cu.748. Affected by this vulnerability is the function clearPairCfg of the file /cgi-bin/cstecgi.cgi of the component HTTP POST Request Handler. The manipulation of the argument ip leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-T6
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-7613
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.64% / 81.66%
||
7 Day CHG+0.68%
Published-14 Jul, 2025 | 14:44
Updated-15 Jul, 2025 | 13:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK T6 HTTP POST Request cstecgi.cgi CloudSrvVersionCheck command injection

A vulnerability was found in TOTOLINK T6 4.1.5cu.748. It has been rated as critical. This issue affects the function CloudSrvVersionCheck of the file /cgi-bin/cstecgi.cgi of the component HTTP POST Request Handler. The manipulation of the argument ip leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-T6
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-7415
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.57% / 68.35%
||
7 Day CHG+0.24%
Published-10 Jul, 2025 | 21:02
Updated-16 Jul, 2025 | 15:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O3V2 httpd getTraceroute fromTraceroutGet command injection

A vulnerability, which was classified as critical, has been found in Tenda O3V2 1.0.0.12(3880). This issue affects the function fromTraceroutGet of the file /goform/getTraceroute of the component httpd. The manipulation of the argument dest leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o3_firmwareo3O3V2
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45600
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.4||HIGH
EPSS-2.20% / 84.14%
||
7 Day CHG~0.00%
Published-26 Dec, 2021 | 00:39
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR750 before 4.6.3.6, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-rbs850cbr750rbs850_firmwarerbr850rbk852rbk852_firmwarecbr750_firmwarerbr850_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45552
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.3||MEDIUM
EPSS-0.19% / 40.39%
||
7 Day CHG~0.00%
Published-26 Dec, 2021 | 00:51
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.58, R7500v2 before 1.0.3.48, R7800 before 1.0.2.68, R8900 before 1.0.5.2, R9000 before 1.0.5.2, RAX120 before 1.0.1.108, and XR700 before 1.0.1.20.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-r7500v2d7800_firmwarer7800r8900r9000_firmwarerax120_firmwarer8900_firmwarer7800_firmwarer7500v2_firmwared7800xr700_firmwarerax120r9000xr700n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-7525
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.61% / 81.47%
||
7 Day CHG+0.67%
Published-13 Jul, 2025 | 09:32
Updated-15 Jul, 2025 | 20:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK T6 HTTP POST Request cstecgi.cgi setTracerouteCfg command injection

A vulnerability was found in TOTOLINK T6 4.1.5cu.748_B20211015. It has been declared as critical. This vulnerability affects the function setTracerouteCfg of the file /cgi-bin/cstecgi.cgi of the component HTTP POST Request Handler. The manipulation of the argument command leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-t6_firmwaret6T6
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-7154
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-2.08% / 83.72%
||
7 Day CHG+1.18%
Published-08 Jul, 2025 | 00:32
Updated-16 Jul, 2025 | 19:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK N200RE cstecgi.cgi sub_41A0F8 os command injection

A vulnerability, which was classified as critical, has been found in TOTOLINK N200RE 9.3.5u.6095_B20200916/9.3.5u.6139_B20201216. Affected by this issue is the function sub_41A0F8 of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument Hostname leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-n200ren200re_firmwareN200RE
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-45597
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.4||HIGH
EPSS-1.46% / 80.60%
||
7 Day CHG~0.00%
Published-26 Dec, 2021 | 00:39
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, and RBS850 before 3.2.17.12.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-cbr40rbs850cbr40_firmwarecbr750rbs850_firmwarerbr850rbk852_firmwarerbk852cbr750_firmwarerbr850_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-7614
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.64% / 81.66%
||
7 Day CHG+0.68%
Published-14 Jul, 2025 | 15:02
Updated-15 Jul, 2025 | 20:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK T6 HTTP POST Request cstecgi.cgi delDevice command injection

A vulnerability classified as critical has been found in TOTOLINK T6 4.1.5cu.748. Affected is the function delDevice of the file /cgi-bin/cstecgi.cgi of the component HTTP POST Request Handler. The manipulation of the argument ipAddr leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-T6
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45547
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.4||HIGH
EPSS-1.43% / 80.39%
||
7 Day CHG~0.00%
Published-26 Dec, 2021 | 00:52
Updated-04 Aug, 2024 | 04:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7850 before 1.0.5.74, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX200 before 1.0.4.120, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, and RBS850 before 3.2.17.12.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-rax200_firmwarerax80r7900p_firmwarerbs750_firmwarer7850_firmwarerbr850_firmwarerbs850_firmwarer8000rax75rbr850rax80_firmwarerbr750_firmwarer8000prbs850rbk752_firmwarer7960prbk752rbr750r8000p_firmwarerbs750r7960p_firmwarer7850rax200rax75_firmwarerbk852_firmwarerbk852r7900pr8000_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
  • Previous
  • 1
  • 2
  • 3
  • 4
  • ...
  • 14
  • 15
  • Next
Details not found