DIGITUS DA-70254 4-Port Gigabit Network Hub 2.073.000.E0008 devices allow an attacker on the same network to elevate privileges because the administrative password can be discovered by sniffing unencrypted UDP traffic.
OpenHarmony-v3.1.1 and prior versions have a permission bypass vulnerability. LAN attackers can bypass permission control and get control of camera service.
A support user exists on the device and appears to be a backdoor for Technical Support staff. The default password for this account is “support” and cannot be changed by a user via any normally accessible means.
This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of D-Link DIR-1935 1.03 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of HNAP login requests. The issue results from the lack of proper implementation of the authentication algorithm. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-16142.
In Patient Information Center iX (PICiX) Version B.02, C.02, C.03, and PerformanceBridge Focal Point Version A.01, when an actor claims to have a given identity, the software does not prove or insufficiently proves the claim is correct.
OpenHarmony-v3.1.2 and prior versions have an authenication bypass vulnerability in a callback handler function of Softbus_server in communication subsystem. Attackers can launch attacks on distributed networks by sending Bluetooth rfcomm packets to any remote device and executing arbitrary commands.
Authentication bypass vulnerability in multiple Buffalo network devices allows a network-adjacent attacker to bypass authentication and access the device. The affected products/versions are as follows: WCR-300 firmware Ver. 1.87 and earlier, WHR-HP-G300N firmware Ver. 2.00 and earlier, WHR-HP-GN firmware Ver. 1.87 and earlier, WPL-05G300 firmware Ver. 1.88 and earlier, WRM-D2133HP firmware Ver. 2.85 and earlier, WRM-D2133HS firmware Ver. 2.96 and earlier, WTR-M2133HP firmware Ver. 2.85 and earlier, WTR-M2133HS firmware Ver. 2.96 and earlier, WXR-1900DHP firmware Ver. 2.50 and earlier, WXR-1900DHP2 firmware Ver. 2.59 and earlier, WXR-1900DHP3 firmware Ver. 2.63 and earlier, WXR-5950AX12 firmware Ver. 3.40 and earlier, WXR-6000AX12B firmware Ver. 3.40 and earlier, WXR-6000AX12S firmware Ver. 3.40 and earlier, WZR-300HP firmware Ver. 2.00 and earlier, WZR-450HP firmware Ver. 2.00 and earlier, WZR-600DHP firmware Ver. 2.00 and earlier, WZR-900DHP firmware Ver. 1.15 and earlier, WZR-1750DHP2 firmware Ver. 2.31 and earlier, WZR-HP-AG300H firmware Ver. 1.76 and earlier, WZR-HP-G302H firmware Ver. 1.86 and earlier, WEM-1266 firmware Ver. 2.85 and earlier, WEM-1266WP firmware Ver. 2.85 and earlier, WLAE-AG300N firmware Ver. 1.86 and earlier, FS-600DHP firmware Ver. 3.40 and earlier, FS-G300N firmware Ver. 3.14 and earlier, FS-HP-G300N firmware Ver. 3.33 and earlier, FS-R600DHP firmware Ver. 3.40 and earlier, BHR-4GRV firmware Ver. 2.00 and earlier, DWR-HP-G300NH firmware Ver. 1.84 and earlier, DWR-PG firmware Ver. 1.83 and earlier, HW-450HP-ZWE firmware Ver. 2.00 and earlier, WER-A54G54 firmware Ver. 1.43 and earlier, WER-AG54 firmware Ver. 1.43 and earlier, WER-AM54G54 firmware Ver. 1.43 and earlier, WER-AMG54 firmware Ver. 1.43 and earlier, WHR-300 firmware Ver. 2.00 and earlier, WHR-300HP firmware Ver. 2.00 and earlier, WHR-AM54G54 firmware Ver. 1.43 and earlier, WHR-AMG54 firmware Ver. 1.43 and earlier, WHR-AMPG firmware Ver. 1.52 and earlier, WHR-G firmware Ver. 1.49 and earlier, WHR-G300N firmware Ver. 1.65 and earlier, WHR-G301N firmware Ver. 1.87 and earlier, WHR-G54S firmware Ver. 1.43 and earlier, WHR-G54S-NI firmware Ver. 1.24 and earlier, WHR-HP-AMPG firmware Ver. 1.43 and earlier, WHR-HP-G firmware Ver. 1.49 and earlier, WHR-HP-G54 firmware Ver. 1.43 and earlier, WLI-H4-D600 firmware Ver. 1.88 and earlier, WS024BF firmware Ver. 1.60 and earlier, WS024BF-NW firmware Ver. 1.60 and earlier, WXR-1750DHP firmware Ver. 2.60 and earlier, WXR-1750DHP2 firmware Ver. 2.60 and earlier, WZR-1166DHP firmware Ver. 2.18 and earlier, WZR-1166DHP2 firmware Ver. 2.18 and earlier, WZR-1750DHP firmware Ver. 2.30 and earlier, WZR2-G300N firmware Ver. 1.55 and earlier, WZR-450HP-CWT firmware Ver. 2.00 and earlier, WZR-450HP-UB firmware Ver. 2.00 and earlier, WZR-600DHP2 firmware Ver. 1.15 and earlier, WZR-600DHP3 firmware Ver. 2.19 and earlier, WZR-900DHP2 firmware Ver. 2.19 and earlier, WZR-AGL300NH firmware Ver. 1.55 and earlier, WZR-AMPG144NH firmware Ver. 1.49 and earlier, WZR-AMPG300NH firmware Ver. 1.51 and earlier, WZR-D1100H firmware Ver. 2.00 and earlier, WZR-G144N firmware Ver. 1.48 and earlier, WZR-G144NH firmware Ver. 1.48 and earlier, WZR-HP-G300NH firmware Ver. 1.84 and earlier, WZR-HP-G301NH firmware Ver. 1.84 and earlier, WZR-HP-G450H firmware Ver. 1.90 and earlier, WZR-S1750DHP firmware Ver. 2.32 and earlier, WZR-S600DHP firmware Ver. 2.19 and earlier, and WZR-S900DHP firmware Ver. 2.19 and earlier.
The WAVLINK Quantum D4G (WN531G3) running firmware version M31G3.V5030.200325 uses IP addresses to hold sessions and does not not use session tokens. Therefore, if an attacker changes their IP address to match the logged-in administrator's, or is behind the same NAT as the logged in administrator, session takeover is possible.
A vulnerability, which was classified as critical, was found in TOTOLINK T6 4.1.5cu.748_B20211015. This affects the function Form_Login of the file /formLoginAuth.htm. The manipulation of the argument authCode/goURL leads to missing authentication. The attack needs to be initiated within the local network. The exploit has been disclosed to the public and may be used.
TP-Link USB Network Server TL-PS310U devices before 2.079.000.t0210 allow an attacker on the same network to bypass authentication via a web-administration request that lacks a password parameter.
CWE-287: Improper Authentication vulnerability exists that could cause unauthorized tampering of device configuration over NFC communication.
NVIDIA UFM Enterprise, UFM Appliance, and UFM CyberAI contain a vulnerability where an attacker can cause an improper authentication issue by sending a malformed request through the Ethernet management interface. A successful exploit of this vulnerability might lead to escalation of privileges, data tampering, denial of service, and information disclosure.
The Bluetooth module of some Huawei Smart Screen products has an identity authentication bypass vulnerability. Successful exploitation of this vulnerability may allow attackers to access restricted functions. Successful exploitation of this vulnerability may allow attackers to access restricted functions.
A vulnerability classified as critical has been found in SATO CL4NX-J Plus 1.13.2-u455_r2. This affects an unknown part of the component Cookie Handler. The manipulation with the input auth=user,level1,settings; web=true leads to improper authentication. Access to the local network is required for this attack. The exploit has been disclosed to the public and may be used. The identifier VDB-241029 was assigned to this vulnerability.
A vulnerability was found in SATO CL4NX-J Plus 1.13.2-u455_r2. It has been declared as critical. Affected by this vulnerability is an unknown functionality of the component WebConfig. The manipulation leads to improper authentication. The attack needs to be done within the local network. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-241027.
An issue was discovered on NETGEAR Orbi Tri-Band Business WiFi Add-on Satellite (SRS60) AC3000 V2.5.1.106, Outdoor Satellite (RBS50Y) V2.5.1.106, and Pro Tri-Band Business WiFi Router (SRR60) AC3000 V2.5.1.106. The administrative SOAP interface allows an unauthenticated remote write of arbitrary Wi-Fi configuration data such as authentication details (e.g., the Web-admin password), network settings, DNS settings, system administration interface configuration, etc.
A limited authentication bypass vulnerability was discovered that could allow an attacker to achieve remote code execution and escalate privileges on the My Cloud devices. Addressed this vulnerability by changing access token validation logic and rewriting rule logic on PHP scripts.
The ABB IDAL HTTP server CGI interface contains a URL that allows an unauthenticated attacker to bypass authentication and gain access to privileged functions. Specifically, /cgi/loginDefaultUser creates a session in an authenticated state and returns the session ID along with what may be the username and cleartext password of the user. An attacker can then supply an IDALToken value in a cookie, which will allow them to perform privileged operations such as restarting the service with /cgi/restart. A GET request to /cgi/loginDefaultUser may result in "1 #S_OK IDALToken=532c8632b86694f0232a68a0897a145c admin admin" or a similar response.
D-Link DAP-1860 devices before v1.04b03 Beta allow access to administrator functions without authentication via the HNAP_AUTH header timestamp value. In HTTP requests, part of the HNAP_AUTH header is the timestamp used to determine the time when the user sent the request. If this value is equal to the value stored in the device's /var/hnap/timestamp file, the request will pass the HNAP_AUTH check function.
Authentication bypass vulnerability in ACERA 1320 firmware ver.01.26 and earlier, and ACERA 1310 firmware ver.01.26 and earlier allows a network-adjacent unauthenticated attacker who can access the affected product to download configuration files and/or log files, and upload configuration files and/or firmware. They are affected when running in ST(Standalone) mode.
beegfs-ctl in ThinkParQ BeeGFS through 7.1.3 allows Authentication Bypass via communication with a BeeGFS metadata server (which is typically not exposed to external networks).
Arris DG860A and DG1670A devices have predictable default WPA2 PSKs that could lead to unauthorized remote access. (They use the first 6 characters of the SSID and the last 6 characters of the BSSID, decrementing the last digit.)
Authentication bypass vulnerability in Fujitsu network devices Si-R series and SR-M series allows a network-adjacent unauthenticated attacker to obtain, change, and/or reset configuration settings of the affected products. Affected products and versions are as follows: Si-R 30B all versions, Si-R 130B all versions, Si-R 90brin all versions, Si-R570B all versions, Si-R370B all versions, Si-R220D all versions, Si-R G100 V02.54 and earlier, Si-R G200 V02.54 and earlier, Si-R G100B V04.12 and earlier, Si-R G110B V04.12 and earlier, Si-R G200B V04.12 and earlier, Si-R G210 V20.52 and earlier, Si-R G211 V20.52 and earlier, Si-R G120 V20.52 and earlier, Si-R G121 V20.52 and earlier, and SR-M 50AP1 all versions.
This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of NETGEAR R7000 1.0.11.116_10.2.100 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the processing of SOAP requests. The issue results from the lack of proper authentication verification before performing a password reset. An attacker can leverage this vulnerability to reset the admin password. Was ZDI-CAN-13483.
This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of multiple NETGEAR routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the mini_httpd service, which listens on TCP port 80 by default. The issue results from incorrect string matching logic when accessing protected pages. An attacker can leverage this vulnerability to escalate privileges and execute arbitrary code in the context of root. Was ZDI-CAN-13313.
The Belkin N300 (F7D7301v1) router allows remote attackers to bypass authentication and gain privileges via vectors related to incorrect validation of the HTTP Authorization header.
The LB-Link BL-CPE300M AX300 4G LTE Router firmware version BL-R8800_B10_ALK_SL_V01.01.02P42U14_06 does not implement proper session handling. After a user authenticates from a specific IP address, the router grants access to any other client using that same IP, without requiring credentials or verifying client identity. There are no session tokens, cookies, or unique identifiers in place. This flaw allows an attacker to obtain full administrative access simply by configuring their device to use the same IP address as a previously authenticated user. This results in a complete authentication bypass.
There is no account authentication and permission check logic in the firmware and existing apps of SiHAS's SGW-300, ACM-300, GCM-300, so unauthorized users can remotely control the device.
Improper authentication vulnerability in Archer C20 firmware versions prior to 'Archer C20(JP)_V1_230616' allows a network-adjacent unauthenticated attacker to execute an arbitrary OS command via a crafted request to bypass authentication.
Improper authentication vulnerability in Tizen bluetooth-frwk prior to Firmware update JUN-2021 Release allows bluetooth attacker to take over the user's bluetooth device without user awareness.
A vulnerability found in UniFi Protect application V1.18.1 and earlier permits a malicious actor who has already gained access to a network to subsequently control the Protect camera(s) assigned to said network. This vulnerability is fixed in UniFi Protect application V1.19.0 and later.
Improper input validation in BLE prior to SMR Jul-2024 Release 1 allows adjacent attackers to trigger abnormal behavior.
Encrypted WiFi and SSH credentials were found in the Ghost Robotics Vision 60 v0.27.2 APK. This vulnerability allows an attacker to connect to the robot's WiFi and view all its data, as it runs on ROS 2 without default authentication. In addition, the attacker can connect via SSH and gain full control of the robot, which could cause physical damage to the robot itself or its environment.
An issue was discovered on COROS PACE 3 devices through 3.0808.0. It starts advertising if no device is connected via Bluetooth. This allows an attacker to connect with the device via BLE if no other device is connected. While connected, none of the BLE services and characteristics of the device require any authentication or security level. Therefore, any characteristic, depending on their mode of operation (read/write/notify), can be used by the connected attacker. This allows, for example, configuring the device, sending notifications, resetting the device to factory settings, or installing software.
This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of D-Link DIR-867, DIR-878, and DIR-882 routers with firmware 1.10B04. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of HNAP login requests. The issue results from the lack of proper implementation of the authentication algorithm. An attacker can leverage this vulnerability to escalate privileges and execute code in the context of the router. Was ZDI-CAN-9470.
This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of D-Link DAP-2610 Firmware v2.01RC067 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of passwords. The issue results from the lack of proper password checking. An attacker can leverage this vulnerability to execute arbitrary code in the context of root. Was ZDI-CAN-10082.
An authentication bypass vulnerability was reported in Lenovo ThinkPad Stack Wireless Router firmware version 1.1.3.4 that could allow escalation of privilege.
Improper authentication for some Intel(R) Server Boards, Server Systems and Compute Modules before version 1.59 may allow an unauthenticated user to potentially enable escalation of privilege via adjacent access.
Improper authentication for some Intel(R) Server Boards, Server Systems and Compute Modules before version 1.59 may allow an unauthenticated user to potentially enable escalation of privilege via adjacent access.
OpenBlocks IoT VX2 prior to Ver.4.0.0 (Ver.3 Series) allows an attacker on the same network segment to bypass authentication and to initialize the device via unspecified vectors.
Waybox Enel X web management API authentication could be bypassed and provide administrator’s privileges over the Waybox system.
Panasonic AiSEG2 versions 2.00J through 2.93A allows adjacent attackers bypass authentication due to mishandling of X-Forwarded-For headers.
The NSDP protocol implementation on NETGEAR JGS516PE/GS116Ev2 v2.6.0.43 devices was affected by an authentication issue that allows an attacker to bypass access controls and obtain full control of the device.
There exists an authentication bypass vulnerability in OpenThread border router devices and implementations. This issue allows unauthenticated nodes to craft radio frames using “Key ID Mode 2”: a special mode using a static encryption key to bypass security checks, resulting in arbitrary IP packets being allowed on the Thread network. This provides a pathway for an attacker to send/receive arbitrary IPv6 packets to devices on the LAN, potentially exploiting them if they lack additional authentication or contain any network vulnerabilities that would normally be mitigated by the home router’s NAT firewall. Effected devices have been mitigated through an automatic update beyond the affected range.
A CWE-287: Improper Authentication vulnerability exists that could allow a device to be compromised when a key of less than seven digits is entered and the attacker has access to the KNX installation.
Authentication bypass vulnerability in Qrio Lock (Q-SL2) firmware version 2.0.9 and earlier allows a network-adjacent attacker to analyze the product's communication data and conduct an arbitrary operation under certain conditions.
Certain NETGEAR devices are affected by authentication bypass. This affects GS110EMX before 1.0.1.7, GS810EMX before 1.7.1.3, XS512EM before 1.0.1.3, and XS724EM before 1.0.1.3.
Dell Storage Center - Dell Storage Manager, version(s) 20.1.20, contain(s) an Improper Authentication vulnerability. An unauthenticated attacker with adjacent network access could potentially exploit this vulnerability, leading to Elevation of privileges.
Lindy 42633 4-Port USB 2.0 Gigabit Network Server 2.078.000 devices allow an attacker on the same network to bypass authentication via a web-administration request that lacks a password parameter.
Improper Authentication vulnerability in ABB Terra AC wallbox (UL40/80A), ABB Terra AC wallbox (UL32A), ABB Terra AC wallbox (CE) (Terra AC MID), ABB Terra AC wallbox (CE) Terra AC Juno CE, ABB Terra AC wallbox (CE) Terra AC PTB, ABB Terra AC wallbox (CE) Symbiosis, ABB Terra AC wallbox (JP).This issue affects Terra AC wallbox (UL40/80A): from 1.0;0 through 1.5.5; Terra AC wallbox (UL32A) : from 1.0;0 through 1.6.5; Terra AC wallbox (CE) (Terra AC MID): from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC Juno CE: from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC PTB : from 1.0;0 through 1.5.25; Terra AC wallbox (CE) Symbiosis: from 1.0;0 through 1.2.7; Terra AC wallbox (JP): from 1.0;0 through 1.6.5.