In SapphireIMS 5.0, it is possible to use the hardcoded credential in clients (username: sapphire, password: ims) and gain access to the portal. Once the access is available, the attacker can inject malicious OS commands on “ping”, “traceroute” and “snmp” functions and execute code on the server. We also observed the same is true if the JSESSIONID is completely removed.
In SapphireIMS 5.0, it is possible to use the hardcoded credential in clients (username: sapphire, password: ims) and gain access to the portal. Once the access is available, the attacker can inject malicious OS commands on “ping”, “traceroute” and “snmp” functions and execute code on the server.
The /root/anaconda-ks.cfg installation configuration file in International Datacasting Corporation (IDC) SFX Series(SFX2100) SuperFlex Satellite Receiver insecurely stores the hardcoded root password hash. The password itself is highly insecure and susceptible to offline dictionary attacks using the rockyou.txt wordlist. Because direct root SSH login is disabled, an attacker must first obtain low-privileged access to the system (e.g., via other vulnerabilities) to be able to log in as the root user. The password is hardcoded and so allows for an actor with local access on effected versions to escalate to root
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 stores usernames, passwords, and other configuration options in the file generated via the "export configuration" feature. The configuration file is encrypted using the awenc binary. The same binary can be used to decrypt any configuration file since all the encryption logic is hard coded. A local attacker can use this vulnerability to gain access to devices username and passwords.
Calero VeraSMART versions prior to 2026 R1 contain hardcoded static AES encryption keys within Veramark.Framework.dll (Veramark.Core.Config class). These keys are used to encrypt the password of the service account stored in C:\\VeraSMART Data\\app.settings. An attacker with local access to the system can extract the hardcoded keys from the Veramark.Framework.dll module and decrypt the stored credentials. The recovered credentials can then be used to authenticate to the Windows host, potentially resulting in local privilege escalation depending on the privileges of the configured service account.
Precor touchscreen console P62, P80, and P82 could allow a remote attacker (within the local network) to bypass security restrictions, and access the service menu, because there is a hard-coded service code.
Due to the implementation of "deriveVaultKey", prior to version 7.10, the generated vault key would always have the last 16 bytes predetermined to be "arfoobarfoobarfo". This issue happens because "deriveVaultKey" calls "retrieveCloudKey" (which will always return "foobarfoobarfoobarfoobarfoobarfo" as the key), and then merges the 32byte randomly generated key with this key (by takeing 16bytes from each, see "mergeKeys"). This makes the key a lot weaker. This issue does not persist in devices that were initialized on/after version 7.10, but devices that were initialized before that and updated to a newer version still have this issue. Roll an update that enforces the full 32bytes key usage.
A use of hard-coded credentials vulnerability [CWE-798] in FortiTester 2.3.0 through 7.2.3 may allow an attacker who managed to get a shell on the device to access the database via shell commands.
The vulnerability allows an unprivileged (untrusted) third- party application to arbitrary modify the server settings of the Android Client application, inducing it to connect to an attacker - controlled malicious server.This is possible by forging a valid broadcast intent encrypted with a hardcoded RSA key pair
A improper authentication vulnerability in Fortinet FortiSIEM before 6.5.0 allows a local attacker with CLI access to perform operations on the Glassfish server directly via a hardcoded password.
Use of a hard-coded cryptographic key pair by the telnetd_startup service allows an attacker on the local area network to obtain a root shell on the device over telnet. The builds of telnetd_startup included in the version 22.5.9.163 of the K2 firmware, and version 32.1.15.93 of the K3C firmware (possibly amongst many other releases) included both the private and public RSA keys. The remaining versions cited here redacted the private key, but left the public key unchanged. An attacker in possession of the leaked private key may, through a scripted exchange of UDP packets, instruct telnetd_startup to spawn an unauthenticated telnet shell as root, by means of which they can then obtain complete control of the device. A consequence of the limited availablility of firmware images for testing is that models and versions not listed here may share this vulnerability.
A Use of Hard-coded Credentials vulnerability in Juniper Networks Junos OS on Junos Fusion satellite devices allows an attacker who is local to the device to elevate their privileges and take control of the device. This issue affects: Juniper Networks Junos OS Junos Fusion Satellite Devices. 16.1 versions prior to 16.1R7-S7; 17.1 versions prior to 17.1R2-S12, 17.1R3-S2; 17.2 versions prior to 17.2R3-S4; 17.3 versions prior to 17.3R3-S8; 17.4 versions prior to 17.4R2-S10; 17.4 version 17.4R3 and later versions; 18.1 versions prior to 18.1R3-S10; 18.2 versions prior to 18.2R2-S7, 18.2R3-S3; 18.3 versions prior to 18.3R1-S7, 18.3R2-S4, 18.3R3-S2; 18.4 versions prior to 18.4R1-S6, 18.4R2-S4, 18.4R3-S1; 19.1 versions prior to 19.1R1-S5, 19.1R2-S1, 19.1R3; 19.2 versions prior to 19.2R1-S4, 19.2R2; 19.3 versions prior to 19.3R2-S5, 19.3R3; 19.4 versions prior to 19.4R1-S1, 19.4R2; 20.1 versions prior to 20.1R1-S1, 20.1R2. This issue does not affected Junos OS releases prior to 16.1R1 or all 19.2R3 and 19.4R3 release versions.
Infor SyteLine ERP uses hard-coded static cryptographic keys to encrypt stored credentials, including user passwords, database connection strings, and API keys. The encryption keys are identical across all installations. An attacker with access to the application binary and database can decrypt all stored credentials.
A use of hard-coded cryptographic key vulnerability [CWE-321] in the registration mechanism of FortiEDR collectors versions 5.0.2, 5.0.1, 5.0.0, 4.0.0 may allow a local attacker to disable and uninstall the collectors from the end-points within the same deployment.
The root password of the Loxone Miniserver Go Gen.2 before 14.2 is calculated using hard-coded secrets and the MAC address. This allows a local user to calculate the root password and escalate privileges.
BD Viper LT system, versions 2.0 and later, contains hardcoded credentials. If exploited, threat actors may be able to access, modify or delete sensitive information, including electronic protected health information (ePHI), protected health information (PHI) and personally identifiable information (PII). BD Viper LT system versions 4.0 and later utilize Microsoft Windows 10 and have additional Operating System hardening configurations which increase the attack complexity required to exploit this vulnerability.
A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05.11 (only with activated debug support)), CP-8050 MASTER MODULE (All versions < CPCI85 V05.11 (only with activated debug support)). The affected devices contain a hard-coded ID in the SSH `authorized_keys` configuration file. An attacker with knowledge of the corresponding private key could login to the device via SSH. Only devices with activated debug support are affected.
A vulnerability has been found in Tenda i24, 4G03 Pro, 4G05, 4G08, G0-8G-PoE, Nova MW5G and TEG5328F up to 65.10.15.6. Affected is an unknown function of the component Shadow File. Such manipulation with the input Fireitup leads to hard-coded credentials. An attack has to be approached locally. The exploit has been disclosed to the public and may be used.
Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 contains a hard-coded password, which provides access to basic biomedical information, limited device settings, and network configuration of the WBM, if connected. The hard-coded password may allow an attacker with physical access to the device to access management functions to make unauthorized configuration changes to biomedical settings such as turn on and off wireless connections and the phase-complete audible alarm that indicates the end of an infusion phase. Baxter has released a new version of the SIGMA Spectrum Infusion System, version 8, which incorporates hardware and software changes.
ROZCOM client CWE-798: Use of Hard-coded Credentials
A security flaw has been discovered in Tenda AC20 16.03.08.12. Affected by this vulnerability is an unknown functionality of the file /etc_ro/shadow. The manipulation leads to hard-coded credentials. It is possible to launch the attack on the local host. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used.
A vulnerability was identified in FNKvision Y215 CCTV Camera 10.194.120.40. Affected by this issue is some unknown functionality of the file /etc/passwd of the component Firmware. Such manipulation leads to hard-coded credentials. Local access is required to approach this attack. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.
TOTOLINK A3000RU V4.1.2cu.5185_B20201128 was discovered to contain a hardcoded password for root at /etc/shadow.sample.
A use of hard-coded credentials vulnerability [CWE-798] in FortiNAC-F version 7.2.0, FortiNAC version 9.4.2 and below, 9.2 all versions, 9.1 all versions, 8.8 all versions, 8.7 all versions may allow an authenticated attacker to access to the database via shell commands.
A Use of Hardcoded Credentials vulnerability exists in AquaView versions 1.60, 7.x, and 8.x that could allow an authenticated local attacker to manipulate users and system settings.
An issue was discovered on Victure WR1200 devices through 1.0.3. The root SSH password never gets updated from its default value of admin. This enables an attacker to gain control of the device through SSH (regardless of whether the admin password was changed on the web interface).
A vulnerability, which was classified as critical, has been found in LB-LINK BL-AC3600 1.0.22. Affected by this issue is some unknown functionality of the file /etc/shadow. The manipulation with the input root:blinkadmin leads to hard-coded credentials. Local access is required to approach this attack. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Static credentials exist in the PostgreSQL data used in ManageEngine Access Manager Plus (AMP) build 4309, ManageEngine Password Manager Pro, and ManageEngine PAM360. These credentials could allow a malicious actor to modify configuration data that would escalate their permissions from that of a low-privileged user to an Administrative user.
Android App 'Wolt Delivery: Food and more' version 4.27.2 and earlier uses hard-coded credentials (API key for an external service), which may allow a local attacker to obtain the hard-coded API key via reverse-engineering the application binary.
Windows Local Security Authority (LSA) Elevation of Privilege Vulnerability
IBM Security Identity Manager 7.0.1 Virtual Appliance contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 153633.
An issue was discovered on TK-Star Q90 Junior GPS horloge 3.1042.9.8656 devices. When using the device at initial setup, a default password is used (123456) for administrative purposes. There is no prompt to change this password. Note that this password can be used in combination with CVE-2019-20470.
Brocade SANnav versions before v2.0 use a hard-coded password, which could allow local authenticated attackers to access a back-end database and gain privileges.
An exposed Telnet Service on the Billion Smart Energy Router SG600R2 with firmware v3.02.rc6 allows a local network attacker to authenticate via hardcoded credentials into a shell, gaining root execution privileges over the device.
GE Mark VIe Controller is shipped with pre-configured hard-coded credentials that may allow root-user access to the controller. A limited application of the affected product may ship without setup and configuration instructions immediately available to the end user. The bulk of controllers go into applications requiring the GE commissioning engineer to change default configurations during the installation process. GE recommends that users reset controller passwords during installation in the operating environment.
A weak default password for the serial port was reported in some Lenovo Personal Cloud Storage devices that could allow unauthorized device access to an attacker with physical access.
A weak default administrator password for the web interface and serial port was reported in some Lenovo Personal Cloud Storage devices that could allow unauthorized device access to an attacker with physical or local network access.
An attacker with local access to the medical office computer can access restricted functions of the Elefant Service tool by using a hard-coded "Hotline" password in the Elefant service binary, which is shipped with the software.
VVX products with software versions including and prior to, UCS 5.9.2 with Better Together over Ethernet Connector (BToE) application 3.9.1, use hard-coded credentials to establish connections between the host application and the device.
An issue was discovered in CommScope Ruckus IoT Controller 1.7.1.0 and earlier. Hard-coded API Keys exist.
The Cisco AMP For Endpoints application allows an authenticated, local attacker to access a static key value stored in the local application software. The vulnerability is due to the use of a static key value stored in the application used to encrypt the connector protection password. An attacker could exploit this vulnerability by gaining local, administrative access to a Windows host and stopping the Cisco AMP for Endpoints service. Cisco Bug IDs: CSCvg42904.
The software contains a hard-coded password that could allow an attacker to take control of the merging unit using these hard-coded credentials on the MU320E (all firmware versions prior to v04A00.1).
GE UR bootloader binary Version 7.00, 7.01 and 7.02 included unused hardcoded credentials. Additionally, a user with physical access to the UR IED can interrupt the boot sequence by rebooting the UR.
SolarWinds Orion Platform before 2020.2.4, as used by various SolarWinds products, installs and uses a SQL Server backend, and stores database credentials to access this backend in a file readable by unprivileged users. As a result, any user having access to the filesystem can read database login details from that file, including the login name and its associated password. Then, the credentials can be used to get database owner access to the SWNetPerfMon.DB database. This gives access to the data collected by SolarWinds applications, and leads to admin access to the applications by inserting or changing authentication data stored in the Accounts table of the database.
D-Link DIR-850L REV. A (with firmware through FW114WWb07_h2ab_beta1) and REV. B (with firmware through FW208WWb02) devices have 0666 /var/run/hostapd* permissions.
In android for MSM, Firefox OS for MSM, QRD Android, with all Android releases from CAF using the Linux kernel, while flashing FRP partition using reference FRP unlock, authentication method can be compromised for static keys.
SonicWall Email Security Virtual Appliance version 10.0.9 and earlier versions contain a default username and a password that is used at initial setup. An attacker could exploit this transitional/temporary user account from the trusted domain to access the Virtual Appliance remotely only when the device is freshly installed and not connected to Mysonicwall.
NMIS/BioDose software V22.02 and previous versions contain executable binaries with plain text hard-coded passwords. These hard-coded passwords could allow unauthorized access to both the application and database.
IBM Security Guardium 10.6, 11.0, and 11.1 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 174851.
IBM QRadar SIEM 7.3 and 7.4 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 196075.