BD Totalys MultiProcessor, versions 1.70 and earlier, contain hardcoded credentials. If exploited, threat actors may be able to access, modify or delete sensitive information, including electronic protected health information (ePHI), protected health information (PHI) and personally identifiable information (PII). Customers using BD Totalys MultiProcessor version 1.70 with Microsoft Windows 10 have additional operating system hardening configurations which increase the attack complexity required to exploit this vulnerability.
BD FACSLyric Research Use Only, Windows 10 Professional Operating System, U.S. and Malaysian Releases, between November 2017 and November 2018 and BD FACSLyric IVD Windows 10 Professional Operating System US release does not properly enforce user access control to privileged accounts, which may allow for unauthorized access to administrative level functions.
The FACSChorus software contains sensitive information stored in plaintext. A threat actor could gain hardcoded secrets used by the application, which include tokens and passwords for administrative accounts.
A hard-coded password issue was discovered in Becton, Dickinson and Company (BD) PerformA, Version 2.0.14.0 and prior versions, and KLA Journal Service, Version 1.0.51 and prior versions. They use hard-coded passwords to access the BD Kiestra Database, which could be leveraged to compromise the confidentiality of limited PHI/PII information stored in the BD Kiestra Database.
Hardcoded credentials are used in specific BD Pyxis products. If exploited, threat actors may be able to gain access to the underlying file system and could potentially exploit application files for information that could be used to decrypt application credentials or gain access to electronic protected health information (ePHI) or other sensitive information.
The root password of the Loxone Miniserver Go Gen.2 before 14.2 is calculated using hard-coded secrets and the MAC address. This allows a local user to calculate the root password and escalate privileges.
ROZCOM client CWE-798: Use of Hard-coded Credentials
A vulnerability has been found in Tenda i24, 4G03 Pro, 4G05, 4G08, G0-8G-PoE, Nova MW5G and TEG5328F up to 65.10.15.6. Affected is an unknown function of the component Shadow File. Such manipulation with the input Fireitup leads to hard-coded credentials. An attack has to be approached locally. The exploit has been disclosed to the public and may be used.
A use of hard-coded credentials vulnerability [CWE-798] in FortiNAC-F version 7.2.0, FortiNAC version 9.4.2 and below, 9.2 all versions, 9.1 all versions, 8.8 all versions, 8.7 all versions may allow an authenticated attacker to access to the database via shell commands.
VVX products with software versions including and prior to, UCS 5.9.2 with Better Together over Ethernet Connector (BToE) application 3.9.1, use hard-coded credentials to establish connections between the host application and the device.
A CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause local privilege escalation when local attacker connects to the database. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)
IBM QRadar SIEM 7.3 and 7.4 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 196075.
TOTOLINK A3000RU V4.1.2cu.5185_B20201128 was discovered to contain a hardcoded password for root at /etc/shadow.sample.
TOTOLINK A950RG V4.1.2cu.5204_B20210112 was discovered to contain a hardcoded password for root at /etc/shadow.sample.
IBM Security Identity Manager 7.0.1 Virtual Appliance contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 153633.
IBM Security Access Manager Appliance 9.0.1.0, 9.0.2.0, 9.0.3.0, 9.0.4.0, and 9.0.5.0 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 152078.
A Use of Hard-coded Credentials vulnerability in Juniper Networks Junos OS on Junos Fusion satellite devices allows an attacker who is local to the device to elevate their privileges and take control of the device. This issue affects: Juniper Networks Junos OS Junos Fusion Satellite Devices. 16.1 versions prior to 16.1R7-S7; 17.1 versions prior to 17.1R2-S12, 17.1R3-S2; 17.2 versions prior to 17.2R3-S4; 17.3 versions prior to 17.3R3-S8; 17.4 versions prior to 17.4R2-S10; 17.4 version 17.4R3 and later versions; 18.1 versions prior to 18.1R3-S10; 18.2 versions prior to 18.2R2-S7, 18.2R3-S3; 18.3 versions prior to 18.3R1-S7, 18.3R2-S4, 18.3R3-S2; 18.4 versions prior to 18.4R1-S6, 18.4R2-S4, 18.4R3-S1; 19.1 versions prior to 19.1R1-S5, 19.1R2-S1, 19.1R3; 19.2 versions prior to 19.2R1-S4, 19.2R2; 19.3 versions prior to 19.3R2-S5, 19.3R3; 19.4 versions prior to 19.4R1-S1, 19.4R2; 20.1 versions prior to 20.1R1-S1, 20.1R2. This issue does not affected Junos OS releases prior to 16.1R1 or all 19.2R3 and 19.4R3 release versions.
Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 contains a hard-coded password, which provides access to basic biomedical information, limited device settings, and network configuration of the WBM, if connected. The hard-coded password may allow an attacker with physical access to the device to access management functions to make unauthorized configuration changes to biomedical settings such as turn on and off wireless connections and the phase-complete audible alarm that indicates the end of an infusion phase. Baxter has released a new version of the SIGMA Spectrum Infusion System, version 8, which incorporates hardware and software changes.
The software contains a hard-coded password that could allow an attacker to take control of the merging unit using these hard-coded credentials on the MU320E (all firmware versions prior to v04A00.1).
SapphireIMS 5 utilized default sapphire:ims credentials to connect the client to server. This credential is saved in ServerConf.config file in the client.
SolarWinds Orion Platform before 2020.2.4, as used by various SolarWinds products, installs and uses a SQL Server backend, and stores database credentials to access this backend in a file readable by unprivileged users. As a result, any user having access to the filesystem can read database login details from that file, including the login name and its associated password. Then, the credentials can be used to get database owner access to the SWNetPerfMon.DB database. This gives access to the data collected by SolarWinds applications, and leads to admin access to the applications by inserting or changing authentication data stored in the Accounts table of the database.
This vulnerability enables ssh access to minikube container using a default password.
An attacker with local access to the medical office computer can access restricted functions of the Elefant Service tool by using a hard-coded "Hotline" password in the Elefant service binary, which is shipped with the software.
A vulnerability in the configuration of a local database installed as part of the Cisco Energy Management Suite (CEMS) could allow an authenticated, local attacker to access and alter confidential data. The vulnerability is due to the installation of the PostgreSQL database with unchanged default access credentials. An attacker could exploit this vulnerability by logging in to the machine where CEMS is installed and establishing a local connection to the database. The fix for this vulnerability randomizes the database access password in new installations; however, the fix will not change the password for existing installations. Users are required to manually change the password, as documented in the Workarounds section of this advisory. There are workarounds that address this vulnerability.
ISOS firmwares from versions 1.81 to 2.00 contain hardcoded credentials from embedded StreamX installer that integrators are not forced to change.
Dell ECS versions 3.8.1.0 through 3.8.1.7 and Dell ObjectScale versions prior to 4.3.0.0, contains a use of hard-coded credentials vulnerability. An unauthenticated attacker with local access could potentially exploit this vulnerability, leading to filesystem access for attacker.
In PCTechSoft PCSecure V5.0.8.xw, use of Hard-coded Credentials in configuration files leads to admin panel access.
D-Link DIR-850L REV. A (with firmware through FW114WWb07_h2ab_beta1) and REV. B (with firmware through FW208WWb02) devices have 0666 /var/run/hostapd* permissions.
The /root/anaconda-ks.cfg installation configuration file in International Datacasting Corporation (IDC) SFX Series(SFX2100) SuperFlex Satellite Receiver insecurely stores the hardcoded root password hash. The password itself is highly insecure and susceptible to offline dictionary attacks using the rockyou.txt wordlist. Because direct root SSH login is disabled, an attacker must first obtain low-privileged access to the system (e.g., via other vulnerabilities) to be able to log in as the root user. The password is hardcoded and so allows for an actor with local access on effected versions to escalate to root
In android for MSM, Firefox OS for MSM, QRD Android, with all Android releases from CAF using the Linux kernel, while flashing FRP partition using reference FRP unlock, authentication method can be compromised for static keys.
An issue was discovered in CommScope Ruckus IoT Controller 1.7.1.0 and earlier. Hard-coded API Keys exist.
Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568.
Calero VeraSMART versions prior to 2026 R1 contain hardcoded static AES encryption keys within Veramark.Framework.dll (Veramark.Core.Config class). These keys are used to encrypt the password of the service account stored in C:\\VeraSMART Data\\app.settings. An attacker with local access to the system can extract the hardcoded keys from the Veramark.Framework.dll module and decrypt the stored credentials. The recovered credentials can then be used to authenticate to the Windows host, potentially resulting in local privilege escalation depending on the privileges of the configured service account.
TOTOLINK A720R V4.1.5cu.532_B20210610 was discovered to contain a hardcoded password for root at /etc/shadow.sample.
Patterson Dental Eaglesoft 21 has AES-256 encryption but there are two ways to obtain a keyfile: (1) keybackup.data > License > Encryption Key or (2) Eaglesoft.Server.Configuration.data > DbEncryptKeyPrimary > Encryption Key. Applicable files are encrypted with keys and salt that are hardcoded into a DLL or EXE file.
Zoom Rooms for macOS clients before version 5.11.4 contain an insecure key generation mechanism. The encryption key used for IPC between the Zoom Rooms daemon service and the Zoom Rooms client was generated using parameters that could be obtained by a local low-privileged application. That key can then be used to interact with the daemon service to execute privileged functions and cause a local denial of service.
TOTOLINK N600R V4.3.0cu.7647_B20210106 was discovered to contain a hardcoded password for root at /etc/shadow.sample.
TOTOLINK A860R V4.1.2cu.5182_B20201027 was discovered to contain a hardcoded password for root at /etc/shadow.sample.
TOTOLINK A810R V4.1.2cu.5182_B20201026 and V5.9c.4050_B20190424 was discovered to contain a hardcoded password for root at /etc/shadow.sample.
TOTOLINK A800R V4.1.2cu.5137_B20200730 was discovered to contain a hardcoded password for root at /etc/shadow.sample.
Dell EMC SCG Policy Manager, versions from 5.10 to 5.12, contain(s) a contain a Hard-coded Cryptographic Key vulnerability. An attacker with the knowledge of the hard-coded sensitive information, could potentially exploit this vulnerability to login to the system to gain admin privileges.
Infor SyteLine ERP uses hard-coded static cryptographic keys to encrypt stored credentials, including user passwords, database connection strings, and API keys. The encryption keys are identical across all installations. An attacker with access to the application binary and database can decrypt all stored credentials.
Dell EMC SCG Policy Manager, versions from 5.10 to 5.12, contain(s) a Hard-coded Password Vulnerability. An attacker, with the knowledge of the hard-coded credentials, could potentially exploit this vulnerability to login to the system to gain admin privileges.
Dell EMC SCG Policy Manager, versions from 5.10 to 5.12, contain(s) a contain a Hard-coded Cryptographic Key vulnerability. An attacker with the knowledge of the hard-coded sensitive information, could potentially exploit this vulnerability to login to the system to gain LDAP user privileges.
An exposed Telnet Service on the Billion Smart Energy Router SG600R2 with firmware v3.02.rc6 allows a local network attacker to authenticate via hardcoded credentials into a shell, gaining root execution privileges over the device.
A vulnerability was identified in FNKvision Y215 CCTV Camera 10.194.120.40. Affected by this issue is some unknown functionality of the file /etc/passwd of the component Firmware. Such manipulation leads to hard-coded credentials. Local access is required to approach this attack. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.
GE Mark VIe Controller is shipped with pre-configured hard-coded credentials that may allow root-user access to the controller. A limited application of the affected product may ship without setup and configuration instructions immediately available to the end user. The bulk of controllers go into applications requiring the GE commissioning engineer to change default configurations during the installation process. GE recommends that users reset controller passwords during installation in the operating environment.
A security flaw has been discovered in Tenda AC20 16.03.08.12. Affected by this vulnerability is an unknown functionality of the file /etc_ro/shadow. The manipulation leads to hard-coded credentials. It is possible to launch the attack on the local host. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used.
A vulnerability, which was classified as critical, has been found in LB-LINK BL-AC3600 1.0.22. Affected by this issue is some unknown functionality of the file /etc/shadow. The manipulation with the input root:blinkadmin leads to hard-coded credentials. Local access is required to approach this attack. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Use of a hard-coded cryptographic key pair by the telnetd_startup service allows an attacker on the local area network to obtain a root shell on the device over telnet. The builds of telnetd_startup included in the version 22.5.9.163 of the K2 firmware, and version 32.1.15.93 of the K3C firmware (possibly amongst many other releases) included both the private and public RSA keys. The remaining versions cited here redacted the private key, but left the public key unchanged. An attacker in possession of the leaked private key may, through a scripted exchange of UDP packets, instruct telnetd_startup to spawn an unauthenticated telnet shell as root, by means of which they can then obtain complete control of the device. A consequence of the limited availablility of firmware images for testing is that models and versions not listed here may share this vulnerability.