Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2020-5758

Summary
Assigner-tenable
Assigner Org ID-5ac1ecc2-367a-4d16-a0b2-35d495ddd0be
Published At-17 Jul, 2020 | 20:35
Updated At-04 Aug, 2024 | 08:39
Rejected At-
Credits

Grandstream UCM6200 series firmware version 1.0.20.23 and below is vulnerable to OS command injection via HTTP. An authenticated remote attacker can execute commands as the root user by sending a crafted HTTP GET to the UCM's "Old" HTTPS API.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:tenable
Assigner Org ID:5ac1ecc2-367a-4d16-a0b2-35d495ddd0be
Published At:17 Jul, 2020 | 20:35
Updated At:04 Aug, 2024 | 08:39
Rejected At:
▼CVE Numbering Authority (CNA)

Grandstream UCM6200 series firmware version 1.0.20.23 and below is vulnerable to OS command injection via HTTP. An authenticated remote attacker can execute commands as the root user by sending a crafted HTTP GET to the UCM's "Old" HTTPS API.

Affected Products
Vendor
n/a
Product
Grandstream UCM6200 Series
Versions
Affected
  • Versions 1.0.20.23 and below
Problem Types
TypeCWE IDDescription
CWECWE-78CWE-78
Type: CWE
CWE ID: CWE-78
Description: CWE-78
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.tenable.com/security/research/tra-2020-42
x_refsource_CONFIRM
Hyperlink: https://www.tenable.com/security/research/tra-2020-42
Resource:
x_refsource_CONFIRM
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.tenable.com/security/research/tra-2020-42
x_refsource_CONFIRM
x_transferred
Hyperlink: https://www.tenable.com/security/research/tra-2020-42
Resource:
x_refsource_CONFIRM
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:vulnreport@tenable.com
Published At:17 Jul, 2020 | 21:15
Updated At:23 Jul, 2020 | 14:29

Grandstream UCM6200 series firmware version 1.0.20.23 and below is vulnerable to OS command injection via HTTP. An authenticated remote attacker can execute commands as the root user by sending a crafted HTTP GET to the UCM's "Old" HTTPS API.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Primary2.09.0HIGH
AV:N/AC:L/Au:S/C:C/I:C/A:C
Type: Primary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 2.0
Base score: 9.0
Base severity: HIGH
Vector:
AV:N/AC:L/Au:S/C:C/I:C/A:C
CPE Matches

grandstream
grandstream
>>ucm6202_firmware>>Versions up to 1.0.20.23(inclusive)
cpe:2.3:o:grandstream:ucm6202_firmware:*:*:*:*:*:*:*:*
grandstream
grandstream
>>ucm6202>>-
cpe:2.3:h:grandstream:ucm6202:-:*:*:*:*:*:*:*
grandstream
grandstream
>>ucm6204_firmware>>Versions up to 1.0.20.23(inclusive)
cpe:2.3:o:grandstream:ucm6204_firmware:*:*:*:*:*:*:*:*
grandstream
grandstream
>>ucm6204>>-
cpe:2.3:h:grandstream:ucm6204:-:*:*:*:*:*:*:*
grandstream
grandstream
>>ucm6208_firmware>>Versions up to 1.0.20.23(inclusive)
cpe:2.3:o:grandstream:ucm6208_firmware:*:*:*:*:*:*:*:*
grandstream
grandstream
>>ucm6208>>-
cpe:2.3:h:grandstream:ucm6208:-:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-78Primarynvd@nist.gov
CWE-78Secondaryvulnreport@tenable.com
CWE ID: CWE-78
Type: Primary
Source: nvd@nist.gov
CWE ID: CWE-78
Type: Secondary
Source: vulnreport@tenable.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://www.tenable.com/cve/CVE-2020-5758nvd@nist.gov
Not Applicable
https://www.tenable.com/security/research/tra-2020-42vulnreport@tenable.com
Broken Link
Third Party Advisory
Hyperlink: https://www.tenable.com/cve/CVE-2020-5758
Source: nvd@nist.gov
Resource:
Not Applicable
Hyperlink: https://www.tenable.com/security/research/tra-2020-42
Source: vulnreport@tenable.com
Resource:
Broken Link
Third Party Advisory

Change History

0
Information is not available yet

Similar CVEs

1157Records found

CVE-2017-6398
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-64.62% / 98.39%
||
7 Day CHG~0.00%
Published-14 Mar, 2017 | 09:02
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in Trend Micro InterScan Messaging Security (Virtual Appliance) 9.1-1600. An authenticated user can execute a terminal command in the context of the web server user (which is root). Besides, the default installation of IMSVA comes with default administrator credentials. The saveCert.imss endpoint takes several user inputs and performs blacklisting. After that, it uses them as arguments to a predefined operating-system command without proper sanitization. However, because of an improper blacklisting rule, it's possible to inject arbitrary commands into it.

Action-Not Available
Vendor-n/aTrend Micro Incorporated
Product-interscan_messaging_security_virtual_appliancen/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-1703
Matching Score-4
Assigner-SonicWall, Inc.
ShareView Details
Matching Score-4
Assigner-SonicWall, Inc.
CVSS Score-8.8||HIGH
EPSS-3.09% / 86.28%
||
7 Day CHG~0.00%
Published-03 Jun, 2022 | 21:10
Updated-03 Aug, 2024 | 00:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Improper neutralization of special elements in the SonicWall SSL-VPN SMA100 series management interface allows a remote authenticated attacker to inject OS Commands which potentially leads to remote command execution vulnerability or denial of service (DoS) attack.

Action-Not Available
Vendor-SonicWall Inc.
Product-sma_410_firmwaresma_210sma_410sma_500v_firmwaresma_500vsma_210_firmwareSMA100
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-47709
Matching Score-4
Assigner-IBM Corporation
ShareView Details
Matching Score-4
Assigner-IBM Corporation
CVSS Score-9.1||CRITICAL
EPSS-0.29% / 52.32%
||
7 Day CHG~0.00%
Published-11 May, 2024 | 13:07
Updated-14 Jan, 2025 | 21:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
IBM Security Guardium command injection

IBM Security Guardium 11.3, 11.4, 11.5, and 12.0 could allow a remote authenticated attacker to execute arbitrary commands on the system by sending a specially crafted request. IBM X-Force ID: 271524.

Action-Not Available
Vendor-IBM Corporation
Product-security_guardiumSecurity Guardiumsecurity_guardium
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-3278
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-7.2||HIGH
EPSS-1.81% / 82.08%
||
7 Day CHG~0.00%
Published-18 Jun, 2020 | 02:15
Updated-15 Nov, 2024 | 17:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Cisco Small Business RV Series Routers Command Injection Vulnerabilities

Multiple vulnerabilities in the web-based management interface of Cisco Small Business RV320 and RV325 Series Routers and Cisco Small Business RV016, RV042, and RV082 Routers could allow an authenticated, remote attacker with administrative privileges to execute arbitrary commands on an affected device. The vulnerabilities exist because the web-based management interface does not properly validate user-supplied input to scripts. An attacker with administrative privileges that are sufficient to log in to the web-based management interface could exploit each vulnerability by sending malicious requests to an affected device. A successful exploit could allow the attacker to execute arbitrary commands with root privileges on the underlying operating system.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-rv325rv320rv042rv016_firmwarerv042grv082rv320_firmwarerv042_firmwarerv325_firmwarerv082_firmwarerv016rv042g_firmwareCisco Small Business RV Series Router Firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-3224
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-8.8||HIGH
EPSS-0.35% / 56.42%
||
7 Day CHG~0.00%
Published-03 Jun, 2020 | 17:42
Updated-15 Nov, 2024 | 17:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Cisco IOS XE Software Web UI Command Injection Vulnerability

A vulnerability in the web-based user interface (web UI) of Cisco IOS XE Software could allow an authenticated, remote attacker with read-only privileges to inject IOS commands to an affected device. The injected commands should require a higher privilege level in order to be executed. The vulnerability is due to insufficient input validation of specific HTTP requests. An attacker could exploit this vulnerability by sending crafted HTTP requests to a specific web UI endpoint on an affected device. A successful exploit could allow the attacker to inject IOS commands to the affected device, which could allow the attacker to alter the configuration of the device or cause a denial of service (DoS) condition.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-ios_xeCisco IOS XE Software 16.11.1
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-3274
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-7.2||HIGH
EPSS-1.81% / 82.08%
||
7 Day CHG~0.00%
Published-18 Jun, 2020 | 02:21
Updated-15 Nov, 2024 | 16:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Cisco Small Business RV Series Routers Command Injection Vulnerabilities

Multiple vulnerabilities in the web-based management interface of Cisco Small Business RV320 and RV325 Series Routers and Cisco Small Business RV016, RV042, and RV082 Routers could allow an authenticated, remote attacker with administrative privileges to execute arbitrary commands on an affected device. The vulnerabilities exist because the web-based management interface does not properly validate user-supplied input to scripts. An attacker with administrative privileges that are sufficient to log in to the web-based management interface could exploit each vulnerability by sending malicious requests to an affected device. A successful exploit could allow the attacker to execute arbitrary commands with root privileges on the underlying operating system.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-rv325rv320rv042rv016_firmwarerv042grv082rv320_firmwarerv042_firmwarerv325_firmwarerv082_firmwarerv016rv042g_firmwareCisco Small Business RV Series Router Firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-0557
Matching Score-4
Assigner-Protect AI (formerly huntr.dev)
ShareView Details
Matching Score-4
Assigner-Protect AI (formerly huntr.dev)
CVSS Score-8.1||HIGH
EPSS-12.55% / 93.69%
||
7 Day CHG~0.00%
Published-11 Feb, 2022 | 08:45
Updated-02 Aug, 2024 | 23:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
OS Command Injection in microweber/microweber

OS Command Injection in Packagist microweber/microweber prior to 1.2.11.

Action-Not Available
Vendor-Microweber (‘Microweber Academy’ Foundation)
Product-microwebermicroweber/microweber
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-35789
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.84% / 73.78%
||
7 Day CHG~0.00%
Published-29 Dec, 2020 | 23:40
Updated-04 Aug, 2024 | 17:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

NETGEAR NMS300 devices before 1.6.0.27 are affected by command injection by an authenticated user.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-nms300_firmwarenms300n/a
CWE ID-CWE-20
Improper Input Validation
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-54136
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-7.2||HIGH
EPSS-0.07% / 22.16%
||
7 Day CHG-0.02%
Published-01 Aug, 2025 | 23:08
Updated-25 Aug, 2025 | 01:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Cursor's Modification of MCP Server Definitions Bypasses Manual Re-approvals

Cursor is a code editor built for programming with AI. In versions 1.2.4 and below, attackers can achieve remote and persistent code execution by modifying an already trusted MCP configuration file inside a shared GitHub repository or editing the file locally on the target's machine. Once a collaborator accepts a harmless MCP, the attacker can silently swap it for a malicious command (e.g., calc.exe) without triggering any warning or re-prompt. If an attacker has write permissions on a user's active branches of a source repository that contains existing MCP servers the user has previously approved, or allows an attacker has arbitrary file-write locally, the attacker can achieve arbitrary code execution. This is fixed in version 1.3.

Action-Not Available
Vendor-anyspherecursor
Product-cursorcursor
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-0999
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-0.30% / 52.92%
||
7 Day CHG~0.00%
Published-11 Apr, 2022 | 19:38
Updated-16 Apr, 2025 | 17:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
mySCADA myPRO Command Injection

An authenticated user may be able to misuse parameters to inject arbitrary operating system commands into mySCADA myPRO versions 8.25.0 and prior.

Action-Not Available
Vendor-myscadamySCADA
Product-mypromyPRO
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-3332
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-8.1||HIGH
EPSS-1.98% / 82.82%
||
7 Day CHG~0.00%
Published-16 Jul, 2020 | 17:21
Updated-15 Nov, 2024 | 16:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Cisco Small Business RV110W, RV130, RV130W, and RV215W Series Routers Command Shell Injection Vulnerability

A vulnerability in the web-based management interface of Cisco Small Business RV110W, RV130, RV130W, and RV215W Series Routers could allow an authenticated, remote attacker to inject arbitrary shell commands that are executed by an affected device. The vulnerability is due to insufficient input validation of user-supplied data. An attacker could exploit this vulnerability by sending a crafted request to the web-based management interface of an affected device. A successful exploit could allow the attacker to execute arbitrary shell commands or scripts with root privileges on the affected device.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-rv130_vpn_routerrv130_vpn_router_firmwarerv215w_wireless-n_vpn_routerrv110w_wireless-n_vpn_firewall_firmwarerv215w_wireless-n_vpn_router_firmwarerv130w_wireless-n_multifunction_vpn_routerrv110w_wireless-n_vpn_firewallrv130w_wireless-n_multifunction_vpn_router_firmwareCisco RV130W Wireless-N Multifunction VPN Router Firmware
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-3377
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-6.3||MEDIUM
EPSS-0.66% / 70.15%
||
7 Day CHG~0.00%
Published-31 Jul, 2020 | 00:00
Updated-13 Nov, 2024 | 18:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Cisco Data Center Network Manager Command Injection Vulnerability

A vulnerability in the Device Manager application of Cisco Data Center Network Manager (DCNM) could allow an authenticated, remote attacker to inject arbitrary commands on the affected device. The vulnerability is due to insufficient validation of user-supplied input. An attacker could exploit this vulnerability by sending crafted arguments to a specific field within the application. A successful exploit could allow the attacker to run commands as the administrator on the DCNM.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-data_center_network_managerCisco Data Center Network Manager
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-3277
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-7.2||HIGH
EPSS-1.81% / 82.08%
||
7 Day CHG~0.00%
Published-18 Jun, 2020 | 02:15
Updated-15 Nov, 2024 | 17:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Cisco Small Business RV Series Routers Command Injection Vulnerabilities

Multiple vulnerabilities in the web-based management interface of Cisco Small Business RV320 and RV325 Series Routers and Cisco Small Business RV016, RV042, and RV082 Routers could allow an authenticated, remote attacker with administrative privileges to execute arbitrary commands on an affected device. The vulnerabilities exist because the web-based management interface does not properly validate user-supplied input to scripts. An attacker with administrative privileges that are sufficient to log in to the web-based management interface could exploit each vulnerability by sending malicious requests to an affected device. A successful exploit could allow the attacker to execute arbitrary commands with root privileges on the underlying operating system.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-rv325rv320rv042rv016_firmwarerv042grv082rv320_firmwarerv042_firmwarerv325_firmwarerv082_firmwarerv016rv042g_firmwareCisco Small Business RV Series Router Firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2017-5255
Matching Score-4
Assigner-Rapid7, Inc.
ShareView Details
Matching Score-4
Assigner-Rapid7, Inc.
CVSS Score-8.8||HIGH
EPSS-71.42% / 98.66%
||
7 Day CHG~0.00%
Published-20 Dec, 2017 | 22:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In version 3.5 and prior of Cambium Networks ePMP firmware, a lack of input sanitation for certain parameters on the web management console allows any authenticated user (including the otherwise low-privilege readonly user) to inject shell meta-characters as part of a specially-crafted POST request to the get_chart function and run OS-level commands, effectively as root.

Action-Not Available
Vendor-cambiumnetworksCambium Networks
Product-epmp_2000epmp_1000_firmwareepmp_2000_firmwareepmp_1000ePMP
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-35714
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-3.82% / 87.67%
||
7 Day CHG~0.00%
Published-26 Dec, 2020 | 00:46
Updated-04 Aug, 2024 | 17:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Belkin LINKSYS RE6500 devices before 1.0.11.001 allow remote authenticated users to execute arbitrary commands via goform/systemCommand?command= in conjunction with the goform/pingstart program.

Action-Not Available
Vendor-n/aLinksys Holdings, Inc.
Product-re6500_firmwarere6500n/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5571
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.14% / 34.23%
||
7 Day CHG~0.00%
Published-04 Jun, 2025 | 05:31
Updated-15 Jul, 2025 | 17:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DCS-932L setSystemAdmin os command injection

A vulnerability was found in D-Link DCS-932L 2.18.01. It has been classified as critical. Affected is the function setSystemAdmin of the file /setSystemAdmin. The manipulation of the argument AdminID leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dcs-932ldcs-932l_firmwareDCS-932L
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-35715
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-4.65% / 88.89%
||
7 Day CHG~0.00%
Published-26 Dec, 2020 | 00:46
Updated-04 Aug, 2024 | 17:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Belkin LINKSYS RE6500 devices before 1.0.012.001 allow remote authenticated users to execute arbitrary commands via shell metacharacters in a filename to the upload_settings.cgi page.

Action-Not Available
Vendor-n/aLinksys Holdings, Inc.
Product-re6500_firmwarere6500n/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-35606
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-81.70% / 99.14%
||
7 Day CHG~0.00%
Published-21 Dec, 2020 | 19:19
Updated-04 Aug, 2024 | 17:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Arbitrary command execution can occur in Webmin through 1.962. Any user authorized for the Package Updates module can execute arbitrary commands with root privileges via vectors involving %0A and %0C. NOTE: this issue exists because of an incomplete fix for CVE-2019-12840.

Action-Not Available
Vendor-n/aWebmin
Product-webminn/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-35578
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.2||HIGH
EPSS-90.44% / 99.59%
||
7 Day CHG~0.00%
Published-13 Jan, 2021 | 20:19
Updated-04 Aug, 2024 | 17:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in the Manage Plugins page in Nagios XI before 5.8.0. Because the line-ending conversion feature is mishandled during a plugin upload, a remote, authenticated admin user can execute operating-system commands.

Action-Not Available
Vendor-n/aNagios Enterprises, LLC
Product-nagios_xin/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-3279
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-7.2||HIGH
EPSS-1.81% / 82.08%
||
7 Day CHG~0.00%
Published-18 Jun, 2020 | 02:15
Updated-15 Nov, 2024 | 17:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Cisco Small Business RV Series Routers Command Injection Vulnerabilities

Multiple vulnerabilities in the web-based management interface of Cisco Small Business RV320 and RV325 Series Routers and Cisco Small Business RV016, RV042, and RV082 Routers could allow an authenticated, remote attacker with administrative privileges to execute arbitrary commands on an affected device. The vulnerabilities exist because the web-based management interface does not properly validate user-supplied input to scripts. An attacker with administrative privileges that are sufficient to log in to the web-based management interface could exploit each vulnerability by sending malicious requests to an affected device. A successful exploit could allow the attacker to execute arbitrary commands with root privileges on the underlying operating system.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-rv325rv320rv042rv016_firmwarerv042grv082rv320_firmwarerv042_firmwarerv325_firmwarerv082_firmwarerv016rv042g_firmwareCisco Small Business RV Series Router Firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-35576
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-69.83% / 98.61%
||
7 Day CHG~0.00%
Published-25 Jan, 2021 | 00:00
Updated-04 Aug, 2024 | 17:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Command Injection issue in the traceroute feature on TP-Link TL-WR841N V13 (JP) with firmware versions prior to 201216 allows authenticated users to execute arbitrary code as root via shell metacharacters, a different vulnerability than CVE-2018-12577.

Action-Not Available
Vendor-n/aTP-Link Systems Inc.
Product-tl-wr841ntl-wr841n_firmwaren/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-3275
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-7.2||HIGH
EPSS-1.81% / 82.08%
||
7 Day CHG~0.00%
Published-18 Jun, 2020 | 02:21
Updated-15 Nov, 2024 | 16:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Cisco Small Business RV Series Routers Command Injection Vulnerabilities

Multiple vulnerabilities in the web-based management interface of Cisco Small Business RV320 and RV325 Series Routers and Cisco Small Business RV016, RV042, and RV082 Routers could allow an authenticated, remote attacker with administrative privileges to execute arbitrary commands on an affected device. The vulnerabilities exist because the web-based management interface does not properly validate user-supplied input to scripts. An attacker with administrative privileges that are sufficient to log in to the web-based management interface could exploit each vulnerability by sending malicious requests to an affected device. A successful exploit could allow the attacker to execute arbitrary commands with root privileges on the underlying operating system.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-rv325rv320rv042rv016_firmwarerv042grv082rv320_firmwarerv042_firmwarerv325_firmwarerv082_firmwarerv016rv042g_firmwareCisco Small Business RV Series Router Firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-3336
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-7.2||HIGH
EPSS-1.39% / 79.58%
||
7 Day CHG~0.00%
Published-18 Jun, 2020 | 02:16
Updated-15 Nov, 2024 | 17:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Cisco TelePresence Collaboration Endpoint and RoomOS Software Command Injection Vulnerability

A vulnerability in the software upgrade process of Cisco TelePresence Collaboration Endpoint Software and Cisco RoomOS Software could allow an authenticated, remote attacker to modify the filesystem to cause a denial of service (DoS) or gain privileged access to the root filesystem. The vulnerability is due to insufficient input validation. An attacker with administrative privileges could exploit this vulnerability by sending requests with malformed parameters to the system using the console, Secure Shell (SSH), or web API. A successful exploit could allow the attacker to modify the device configuration or cause a DoS.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-roomostelepresence_collaboration_endpointCisco TelePresence CE Software
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-3454
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-7.2||HIGH
EPSS-1.76% / 81.83%
||
7 Day CHG-0.28%
Published-27 Aug, 2020 | 15:40
Updated-13 Nov, 2024 | 18:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Cisco NX-OS Software Call Home Command Injection Vulnerability

A vulnerability in the Call Home feature of Cisco NX-OS Software could allow an authenticated, remote attacker to inject arbitrary commands that could be executed with root privileges on the underlying operating system (OS). The vulnerability is due to insufficient input validation of specific Call Home configuration parameters when the software is configured for transport method HTTP. An attacker could exploit this vulnerability by modifying parameters within the Call Home configuration on an affected device. A successful exploit could allow the attacker to execute arbitrary commands with root privileges on the underlying OS.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-nexus_93180lc-exnexus_56128pnexus_9332pqnexus_3172tqnexus_93108tc-exnexus_3636c-rnx-osnexus_9508nexus_93120txnexus_93128txnexus_9336pq_aci_spinenexus_6004nexus_3548-xlnexus_31128pqnexus_3132q-vnexus_9332cnexus_9364cnexus_3164qnexus_92348gc-xnexus_3172tq-32tnexus_9336c-fx2nexus_3524-xnexus_3132c-znexus_31108tc-vnexus_5548pnexus_9348gc-fxpnexus_5648qnexus_3172mds_9000nexus_9272qnexus_3464cnexus_93216tc-fx2nexus_36180yc-rnexus_5672upnexus_93180yc-fxnexus_3264qnexus_3432d-snexus_34180ycnexus_9000vmds_9509nexus_31108pc-vnexus_5596upnexus_3524nexus_3548nexus_3132qnexus_3016nexus_9372pxnexus_5696qnexus_92304qcnexus_92160yc-xmds_9100nexus_9504nexus_3048nexus_9372tx-enexus_6001nexus_93108tc-fxnexus_93360yc-fx2nexus_3524-xlnexus_9396txnexus_7000nexus_92300ycnexus_3064nexus_3232cnexus_5548upnexus_9396pxnexus_5596tnexus_3264c-enexus_93240yc-fx2nexus_9372txnexus_5624qnexus_3548-xnexus_3132q-xlnexus_3064-tmds_9710nexus_3172tq-xlnexus_93180yc-exnexus_3408-snexus_9372px-enexus_9236cnexus_9516mds_9134nexus_3172pq-xlnexus_7700Cisco NX-OS Software 5.0(1a)
CWE ID-CWE-20
Improper Input Validation
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-3211
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-7.2||HIGH
EPSS-1.34% / 79.25%
||
7 Day CHG~0.00%
Published-03 Jun, 2020 | 17:40
Updated-15 Nov, 2024 | 17:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Cisco IOS XE Software Web UI Command Injection Vulnerability

A vulnerability in the web UI of Cisco IOS XE Software could allow an authenticated, remote attacker to execute arbitrary commands with root privileges on the underlying operating system of an affected device. The vulnerability is due to improper input sanitization. An attacker who has valid administrative access to an affected device could exploit this vulnerability by supplying a crafted input parameter on a form in the web UI and then submitting that form. A successful exploit could allow the attacker to execute arbitrary commands with root privileges on the device, which could lead to complete system compromise.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-ios_xeCisco IOS XE Software 16.10.1
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-3371
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-6.3||MEDIUM
EPSS-2.21% / 83.79%
||
7 Day CHG~0.00%
Published-06 Nov, 2020 | 18:16
Updated-13 Nov, 2024 | 17:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Cisco Integrated Management Controller Command Injection Vulnerability

A vulnerability in the web UI of Cisco Integrated Management Controller (IMC) could allow an authenticated, remote attacker to inject arbitrary code and execute arbitrary commands at the underlying operating system level. The vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by sending crafted commands to the web-based management interface of the affected software. A successful exploit could allow the attacker to inject and execute arbitrary commands at the underlying operating system level.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-integrated_management_controllerCisco Unified Computing System (Standalone)
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-3276
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-7.2||HIGH
EPSS-1.81% / 82.08%
||
7 Day CHG~0.00%
Published-18 Jun, 2020 | 02:21
Updated-15 Nov, 2024 | 16:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Cisco Small Business RV Series Routers Command Injection Vulnerabilities

Multiple vulnerabilities in the web-based management interface of Cisco Small Business RV320 and RV325 Series Routers and Cisco Small Business RV016, RV042, and RV082 Routers could allow an authenticated, remote attacker with administrative privileges to execute arbitrary commands on an affected device. The vulnerabilities exist because the web-based management interface does not properly validate user-supplied input to scripts. An attacker with administrative privileges that are sufficient to log in to the web-based management interface could exploit each vulnerability by sending malicious requests to an affected device. A successful exploit could allow the attacker to execute arbitrary commands with root privileges on the underlying operating system.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-rv325rv320rv042rv016_firmwarerv042grv082rv320_firmwarerv042_firmwarerv325_firmwarerv082_firmwarerv016rv042g_firmwareCisco Small Business RV Series Router Firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-28884
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.2||HIGH
EPSS-4.84% / 89.11%
||
7 Day CHG~0.00%
Published-28 Jan, 2022 | 00:00
Updated-04 Aug, 2024 | 17:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Liferay Portal Server tested on 7.3.5 GA6, 7.2.0 GA1 is affected by OS Command Injection. An administrator user can inject Groovy script to execute any OS command on the Liferay Portal Sever. NOTE: The developer disputes this as a vulnerability since it is a feature for administrators to run groovy scripts and therefore not a design flaw.

Action-Not Available
Vendor-n/aLiferay Inc.
Product-liferay_portaln/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5440
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.39% / 59.13%
||
7 Day CHG~0.00%
Published-02 Jun, 2025 | 10:00
Updated-02 Jul, 2025 | 18:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 NTP os command injection

A vulnerability classified as critical has been found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This affects the function NTP of the file /goform/NTP. The manipulation of the argument manual_year_select/manual_month_select/manual_day_select/manual_hour_select/manual_min_select/manual_sec_select leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re9000_firmwarere6250re7000re6300re6300_firmwarere7000_firmwarere6500_firmwarere9000re6350re6350_firmwarere6250_firmwarere6500RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-23661
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-9.1||CRITICAL
EPSS-2.39% / 84.40%
||
7 Day CHG~0.00%
Published-16 May, 2022 | 19:35
Updated-03 Aug, 2024 | 03:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A authenticated remote command injection vulnerability was discovered in Aruba ClearPass Policy Manager version(s): 6.10.4 and below, 6.9.9 and below, 6.8.9-HF2 and below, 6.7.x and below. Aruba has released updates to ClearPass Policy Manager that address this security vulnerability.

Action-Not Available
Vendor-n/aAruba Networks
Product-clearpass_policy_managerAruba ClearPass Policy Manager
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-24237
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-29.57% / 96.45%
||
7 Day CHG~0.00%
Published-21 Mar, 2022 | 17:24
Updated-03 Aug, 2024 | 04:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The snaptPowered2 component of Snapt Aria v12.8 was discovered to contain a command injection vulnerability. This vulnerability allows authenticated attackers to execute arbitrary commands.

Action-Not Available
Vendor-snaptn/a
Product-arian/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-47565
Matching Score-4
Assigner-QNAP Systems, Inc.
ShareView Details
Matching Score-4
Assigner-QNAP Systems, Inc.
CVSS Score-8||HIGH
EPSS-79.95% / 99.07%
||
7 Day CHG~0.00%
Published-08 Dec, 2023 | 16:06
Updated-30 Jul, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Known KEV||Action Due Date - 2024-01-11||Apply mitigations per vendor instructions or discontinue use of the product if mitigations are unavailable.
Legacy VioStor NVR

An OS command injection vulnerability has been found to affect legacy QNAP VioStor NVR models running QVR Firmware 4.x. If exploited, the vulnerability could allow authenticated users to execute commands via a network. We have already fixed the vulnerability in the following versions: QVR Firmware 5.0.0 and later

Action-Not Available
Vendor-QNAP Systems, Inc.
Product-qvr_firmwareVioStor NVRVioStor NVR
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-28581
Matching Score-4
Assigner-Trend Micro, Inc.
ShareView Details
Matching Score-4
Assigner-Trend Micro, Inc.
CVSS Score-7.2||HIGH
EPSS-75.37% / 98.84%
||
7 Day CHG~0.00%
Published-18 Nov, 2020 | 18:45
Updated-04 Aug, 2024 | 16:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A command injection vulnerability in ModifyVLANItem of Trend Micro InterScan Web Security Virtual Appliance 6.5 SP2 could allow an authenticated, remote attacker to send specially crafted HTTP messages and execute arbitrary OS commands with elevated privileges.

Action-Not Available
Vendor-Trend Micro Incorporated
Product-interscan_web_security_virtual_applianceTrend Micro InterScan Web Security Virtual Appliance
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-23666
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-9.1||CRITICAL
EPSS-2.39% / 84.40%
||
7 Day CHG~0.00%
Published-16 May, 2022 | 19:49
Updated-03 Aug, 2024 | 03:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A authenticated remote command injection vulnerability was discovered in Aruba ClearPass Policy Manager version(s): 6.10.4 and below, 6.9.9 and below, 6.8.9-HF2 and below, 6.7.x and below. Aruba has released updates to ClearPass Policy Manager that address this security vulnerability.

Action-Not Available
Vendor-n/aAruba Networks
Product-clearpass_policy_managerAruba ClearPass Policy Manager
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-23664
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-9.1||CRITICAL
EPSS-2.39% / 84.40%
||
7 Day CHG~0.00%
Published-16 May, 2022 | 19:37
Updated-03 Aug, 2024 | 03:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A authenticated remote command injection vulnerability was discovered in Aruba ClearPass Policy Manager version(s): 6.10.4 and below, 6.9.9 and below, 6.8.9-HF2 and below, 6.7.x and below. Aruba has released updates to ClearPass Policy Manager that address this security vulnerability.

Action-Not Available
Vendor-n/aAruba Networks
Product-clearpass_policy_managerAruba ClearPass Policy Manager
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-24394
Matching Score-4
Assigner-Fidelis Cybersecurity, Inc.
ShareView Details
Matching Score-4
Assigner-Fidelis Cybersecurity, Inc.
CVSS Score-8.8||HIGH
EPSS-0.68% / 70.73%
||
7 Day CHG~0.00%
Published-17 May, 2022 | 19:22
Updated-17 Sep, 2024 | 03:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Authenticated Command Injection Vulnerability in Fidelis Network and Deception

Vulnerability in Fidelis Network and Deception CommandPost enables authenticated command injection through the web interface using the “update_checkfile” value for the “filename” parameter. The vulnerability could allow a specially crafted HTTP request to execute system commands on the CommandPost and return results in an HTTP response via an authenticated session. The vulnerability is present in Fidelis Network and Deception versions prior to 9.4.5. Patches and updates are available to address this vulnerability.

Action-Not Available
Vendor-fidelissecurityFidelis Cybersecurity
Product-deceptionnetworkFidelis DeceptionFidelis Network
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2022-23662
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-9.1||CRITICAL
EPSS-2.39% / 84.40%
||
7 Day CHG~0.00%
Published-16 May, 2022 | 19:32
Updated-03 Aug, 2024 | 03:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A authenticated remote command injection vulnerability was discovered in Aruba ClearPass Policy Manager version(s): 6.10.4 and below, 6.9.9 and below, 6.8.9-HF2 and below, 6.7.x and below. Aruba has released updates to ClearPass Policy Manager that address this security vulnerability.

Action-Not Available
Vendor-n/aAruba Networks
Product-clearpass_policy_managerAruba ClearPass Policy Manager
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-29017
Matching Score-4
Assigner-Fortinet, Inc.
ShareView Details
Matching Score-4
Assigner-Fortinet, Inc.
CVSS Score-8.8||HIGH
EPSS-6.37% / 90.61%
||
7 Day CHG~0.00%
Published-14 Jan, 2021 | 16:03
Updated-25 Oct, 2024 | 14:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An OS command injection vulnerability in FortiDeceptor 3.1.0, 3.0.1, 3.0.0 may allow a remote authenticated attacker to execute arbitrary commands on the system by exploiting a command injection vulnerability on the Customization page.

Action-Not Available
Vendor-n/aFortinet, Inc.
Product-fortideceptorFortinet FortiDeceptor
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-28580
Matching Score-4
Assigner-Trend Micro, Inc.
ShareView Details
Matching Score-4
Assigner-Trend Micro, Inc.
CVSS Score-7.2||HIGH
EPSS-75.37% / 98.84%
||
7 Day CHG~0.00%
Published-18 Nov, 2020 | 18:45
Updated-04 Aug, 2024 | 16:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A command injection vulnerability in AddVLANItem of Trend Micro InterScan Web Security Virtual Appliance 6.5 SP2 could allow an authenticated, remote attacker to send specially crafted HTTP messages and execute arbitrary OS commands with elevated privileges.

Action-Not Available
Vendor-Trend Micro Incorporated
Product-interscan_web_security_virtual_applianceTrend Micro InterScan Web Security Virtual Appliance
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-44981
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-7.06% / 91.13%
||
7 Day CHG~0.00%
Published-24 Jan, 2022 | 12:26
Updated-04 Aug, 2024 | 04:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In QuickBox Pro v2.5.8 and below, the config.php file has a variable which takes a GET parameter value and parses it into a shell_exec(''); function without properly sanitizing any shell arguments, therefore remote code execution is possible. Additionally, as the media server is running as root by default attackers can use the sudo command within this shell_exec(''); function, which allows for privilege escalation by means of RCE.

Action-Not Available
Vendor-quickboxn/a
Product-quickboxn/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-39780
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-70.19% / 98.62%
||
7 Day CHG~0.00%
Published-11 Sep, 2023 | 00:00
Updated-30 Jul, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Known KEV||Action Due Date - 2025-06-23||Apply mitigations per vendor instructions, follow applicable BOD 22-01 guidance for cloud services, or discontinue use of the product if mitigations are unavailable.

On ASUS RT-AX55 3.0.0.4.386.51598 devices, authenticated attackers can perform OS command injection via the /start_apply.htm qos_bw_rulelist parameter. NOTE: for the similar "token-generated module" issue, see CVE-2023-41345; for the similar "token-refresh module" issue, see CVE-2023-41346; for the similar "check token module" issue, see CVE-2023-41347; and for the similar "code-authentication module" issue, see CVE-2023-41348.

Action-Not Available
Vendor-ASUS (ASUSTeK Computer Inc.)
Product-rt-ax55rt-ax55_firmwareRT-AX55rt-ax55RT-AX55 Routers
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2017-2890
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-9.9||CRITICAL
EPSS-1.62% / 81.07%
||
7 Day CHG~0.00%
Published-07 Nov, 2017 | 16:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An exploitable vulnerability exists in the /api/CONFIG/restore functionality of Circle with Disney running firmware 2.0.1. Specially crafted network packets can cause an OS command injection. An attacker can send an HTTP request trigger this vulnerability.

Action-Not Available
Vendor-meetcircleCircle Media
Product-circle_with_disneycircle_with_disney_firmwareCircle
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2017-2848
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-8.8||HIGH
EPSS-1.96% / 82.74%
||
7 Day CHG~0.00%
Published-29 Jun, 2017 | 17:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In the web management interface in Foscam C1 Indoor HD cameras with application firmware 2.52.2.37, a specially crafted HTTP request can allow for a user to inject arbitrary shell characters during manual network configuration resulting in command injection. An attacker can simply send an HTTP request to the device to trigger this vulnerability.

Action-Not Available
Vendor-foscamFoscam
Product-c1_indoor_hd_camerac1_indoor_hd_camera_firmwareIndoor IP Camera C1 Series
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2017-2846
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-8.8||HIGH
EPSS-1.62% / 81.08%
||
7 Day CHG~0.00%
Published-29 Jun, 2017 | 17:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In the web management interface in Foscam C1 Indoor HD cameras with application firmware 2.52.2.37, a specially crafted HTTP request can allow for a user to inject arbitrary shell characters during manual network configuration resulting in command injection. An attacker can simply send an HTTP request to the device to trigger this vulnerability.

Action-Not Available
Vendor-foscamFoscam
Product-c1_indoor_hd_camerac1_indoor_hd_camera_firmwareIndoor IP Camera C1 Series
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-24392
Matching Score-4
Assigner-Fidelis Cybersecurity, Inc.
ShareView Details
Matching Score-4
Assigner-Fidelis Cybersecurity, Inc.
CVSS Score-8.8||HIGH
EPSS-0.68% / 70.73%
||
7 Day CHG~0.00%
Published-17 May, 2022 | 19:26
Updated-16 Sep, 2024 | 16:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Authenticated Command Injection Vulnerability in Fidelis Network and Deception

Vulnerability in Fidelis Network and Deception CommandPost enables authenticated command injection through the web interface using the “feed_comm_test” value for the “feed” parameter. The vulnerability could allow a specially crafted HTTP request to execute system commands on the CommandPost and return results in an HTTP response via an authenticated session. The vulnerability is present in Fidelis Network and Deception versions prior to 9.4.5. Patches and updates are available to address this vulnerability.

Action-Not Available
Vendor-fidelissecurityFidelis Cybersecurity
Product-deceptionnetworkFidelis DeceptionFidelis Network
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-5439
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.39% / 59.13%
||
7 Day CHG~0.00%
Published-02 Jun, 2025 | 09:31
Updated-02 Jul, 2025 | 18:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 verifyFacebookLike os command injection

A vulnerability was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. It has been rated as critical. Affected by this issue is the function verifyFacebookLike of the file /goform/verifyFacebookLike. The manipulation of the argument uid/accessToken leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re9000_firmwarere6250re7000re6300re6300_firmwarere7000_firmwarere6500_firmwarere9000re6350re6350_firmwarere6250_firmwarere6500RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2017-2828
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-8.8||HIGH
EPSS-1.65% / 81.28%
||
7 Day CHG~0.00%
Published-21 Jun, 2017 | 13:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An exploitable command injection vulnerability exists in the web management interface used by the Foscam C1 Indoor HD Camera running application firmware 2.52.2.37. A specially crafted HTTP request can allow for a user to inject arbitrary shell characters during account creation resulting in command injection. An attacker can simply send an HTTP request to the device to trigger this vulnerability.

Action-Not Available
Vendor-foscamFoscam
Product-c1_indoor_hd_camerac1_indoor_hd_camera_firmwareIndoor IP Camera C1 Series
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-24288
Matching Score-4
Assigner-Apache Software Foundation
ShareView Details
Matching Score-4
Assigner-Apache Software Foundation
CVSS Score-8.8||HIGH
EPSS-91.64% / 99.67%
||
7 Day CHG~0.00%
Published-25 Feb, 2022 | 08:30
Updated-03 Aug, 2024 | 04:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Apache Airflow: RCE in example DAGs

In Apache Airflow, prior to version 2.2.4, some example DAGs did not properly sanitize user-provided params, making them susceptible to OS Command Injection from the web UI.

Action-Not Available
Vendor-The Apache Software Foundation
Product-airflowApache Airflow
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2017-2275
Matching Score-4
Assigner-JPCERT/CC
ShareView Details
Matching Score-4
Assigner-JPCERT/CC
CVSS Score-7.2||HIGH
EPSS-0.52% / 65.85%
||
7 Day CHG~0.00%
Published-22 Jul, 2017 | 00:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

WG-C10 v3.0.79 and earlier allows an attacker to execute arbitrary OS commands via unspecified vectors.

Action-Not Available
Vendor-Sony Group Corporation
Product-wg-c10wg-c10_firmwareWG-C10
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-11953
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.85% / 73.91%
||
7 Day CHG~0.00%
Published-14 Jul, 2020 | 13:02
Updated-04 Aug, 2024 | 11:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered on Rittal PDU-3C002DEC through 5.15.40 and CMCIII-PU-9333E0FB through 3.15.70_4 devices. Attackers can execute code.

Action-Not Available
Vendor-rittaln/a
Product-cmciii-pu-9333e0fb_firmwarepdu-3c002dec_firmwareiot_interface_3124.300lcp-cw_firmwarecmc_iii_pu_7030.000_firmwarecmciii-pu-9333e0fbpdu-3c002declcp-cwcmc_iii_pu_7030.000n/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
  • Previous
  • 1
  • 2
  • ...
  • 6
  • 7
  • 8
  • ...
  • 23
  • 24
  • Next
Details not found