Zoho ManageEngine OpManager before 125120 allows an unauthenticated user to retrieve an API key via a servlet call.
An issue was discovered in the Responsive Poll through 1.3.4 for Wordpress. It allows an unauthenticated user to manipulate polls, e.g., delete, clone, or view a hidden poll. This is due to the usage of the callback wp_ajax_nopriv function in Includes/Total-Soft-Poll-Ajax.php for sensitive operations.
authentik is an open-source identity provider. Versions prior to 2022.11.2 and 2022.10.2 are vulnerable to unauthorized user creation and potential account takeover. With the default flows, unauthenticated users can create new accounts in authentik. If a flow exists that allows for email-verified password recovery, this can be used to overwrite the email address of admin accounts and take over their accounts. authentik 2022.11.2 and 2022.10.2 fix this issue. As a workaround, a policy can be created and bound to the `default-user-settings-flow flow` with the contents `return request.user.is_authenticated`.
PRTG Network Monitor before 20.1.57.1745 allows remote unauthenticated attackers to obtain information about probes running or the server itself (CPU usage, memory, Windows version, and internal statistics) via an HTTP request, as demonstrated by type=probes to login.htm or index.htm.
vBulletin before 5.5.6pl1, 5.6.0 before 5.6.0pl1, and 5.6.1 before 5.6.1pl1 has incorrect access control.
Arbitrary code execution vulnerability on Micro Focus Operation Bridge Reporter, affecting version 10.40 and earlier. The vulnerability could allow remote attackers to execute arbitrary code on affected installations of OBR.
Missing authentication for critical function in AssetView prior to Ver.13.2.0 allows a remote unauthenticated attacker with some knowledge on the system configuration to upload a crafted configuration file to the managing server, which may result in the managed clients to execute arbitrary code with the administrative privilege.
Moxa Service in Moxa NPort 5150A firmware version 1.5 and earlier allows attackers to obtain sensitive configuration values via a crafted packet to UDP port 4800. NOTE: Moxa Service is an unauthenticated service that runs upon a first-time installation but can be disabled without ill effect.
If Apache TomEE is configured to use the embedded ActiveMQ broker, and the broker URI includes the useJMX=true parameter, a JMX port is opened on TCP port 1099, which does not include authentication. This affects Apache TomEE 8.0.0-M1 - 8.0.1, Apache TomEE 7.1.0 - 7.1.2, Apache TomEE 7.0.0-M1 - 7.0.7, Apache TomEE 1.0.0 - 1.7.5.
Xiaomi router R3600 ROM before 1.0.50 is affected by a sensitive information leakage caused by an insecure interface get_config_result without authentication
HGiga EIP product lacks ineffective access control in certain pages that allow attackers to access database or perform privileged functions.
Improper Authorization vulnerability of Pepperl+Fuchs P+F Comtrol RocketLinx ES7510-XT, ES8509-XT, ES8510-XT, ES9528-XTv2, ES7506, ES7510, ES7528, ES8508, ES8508F, ES8510, ES8510-XTE, ES9528/ES9528-XT (all versions) allows unauthenticated device administration.
In ONAP OOM through Dublin, by accessing an applicable port (30234, 30290, 32010, 30270, 30224, 30281, 30254, 30285, and/or 30271), an attacker gains full access to the respective ONAP services without any authentication. All ONAP Operations Manager (OOM) setups are affected.
GE Grid Solutions Reason RT Clocks, RT430, RT431, and RT434, all firmware versions prior to 08A05. The device’s vulnerability in the web application could allow multiple unauthenticated attacks that could cause serious impact. The vulnerability may allow an unauthenticated attacker to execute arbitrary commands and send a request to a specific URL that could cause the device to become unresponsive. The unauthenticated attacker may change the password of the 'configuration' user account, allowing the attacker to modify the configuration of the device via the web interface using the new password. This vulnerability may also allow an unauthenticated attacker to bypass the authentication required to configure the device and reboot the system.
An issue was discovered in ONAP VNFSDK through Dublin. By accessing port 8000 of demo-vnfsdk-vnfsdk, an unauthenticated attacker (who already has access to pod-to-pod communication) may execute arbitrary code inside that pod. All ONAP Operations Manager (OOM) setups are affected.
In ONAP CLI through Dublin, by accessing an applicable port (30234, 30290, 32010, 30270, 30224, 30281, 30254, 30285, and/or 30271), an attacker gains full access to the respective ONAP services without any authentication. All ONAP Operations Manager (OOM) setups are affected.
In ONAP SO through Dublin, by accessing an applicable port (30234, 30290, 32010, 30270, 30224, 30281, 30254, 30285, and/or 30271), an attacker gains full access to the respective ONAP services without any authentication. All ONAP Operations Manager (OOM) setups are affected.
Anviz access control devices expose credentials (names and passwords) by allowing remote attackers to query this information without credentials via port tcp/5010.
TeamPass 2.1.27.36 allows an unauthenticated attacker to retrieve files from the TeamPass web root. This may include backups or LDAP debug files.
A Missing Authentication vulnerability in RobotWare for the OmniCore robot controller allows an attacker to read and modify files on the robot controller if the attacker has access to the Connected Services Gateway Ethernet port.
Access to the Advantech iView versions prior to v5.7.03.6112 configuration are missing authentication, which may allow an unauthorized attacker to change the configuration and obtain code execution.
There is a Missing Authentication for Critical Function vulnerability in Huawei Smartphone. Successful exploitation of this vulnerability may impair data confidentiality.
xlockmore 5.13 and 5.22 segfaults when using libpam-opensc and returns the underlying xsession. This allows unauthorized users access to the X session.
An issue was discovered on Samsung mobile devices with Q(10.0) software. The DeX Lockscreen allows attackers to access the quick panel and notifications. The Samsung ID is SVE-2019-16532 (March 2020).
xlockmore 5.13 allows potential xlock bypass when FVWM switches to the same virtual desktop as a new Gaim window.
Password recovery vulnerability in SICK SIM1004 Partnumber 1098148 with firmware version <2.0.0 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The recommended solution is to update the firmware to a version >= 2.0.0 as soon as possible (available in SICK Support Portal).
A vulnerability was found in SourceCodester Company Website CMS 1.0. It has been declared as critical. Affected by this vulnerability is an unknown functionality of the file /dashboard/settings. The manipulation leads to improper authentication. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-206161 was assigned to this vulnerability.
A CWE-306: Missing Authentication for Critical Function vulnerability exists in Easergy T200 ((Modbus) SC2-04MOD-07000100 and earlier), Easergy T200 ((IEC104) SC2-04IEC-07000100 and earlier), and Easergy T200 ((DNP3) SC2-04DNP-07000102 and earlier) that could cause unauthorized operation when authentication is bypassed.
The vCenter Server contains an information disclosure vulnerability due to an unauthenticated appliance management API. A malicious actor with network access to port 443 on vCenter Server may exploit this issue to gain access to sensitive information.
Password recovery vulnerability in SICK SIM2000ST Partnumber 1080579 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The firmware versions <=1.7.0 allow to optionally disable device configuration over the network interfaces. Please make sure that you apply general security practices when operating the SIM2000ST. A fix is planned but not yet scheduled.
Fujifilm FCR Capsula X/ Carbon X/ FCR XC-2, model versions CR-IR 357 FCR Carbon X, CR-IR 357 FCR XC-2, FCR-IR 357 FCR Capsula X provide insecure telnet services that lack authentication requirements. An attacker who successfully exploits this vulnerability may be able to access the underlying operating system.
Emerson OpenEnterprise versions through 3.3.4 may allow an attacker to run an arbitrary commands with system privileges or perform remote code execution via a specific communication service.
WebAccess/NMS (versions prior to 3.0.2) allows an unauthenticated remote user to create a new admin account.
authentik is an open-source Identity Provider. Prior to versions 2023.8.4 and 2023.10.2, when the default admin user has been deleted, it is potentially possible for an attacker to set the password of the default admin user without any authentication. authentik uses a blueprint to create the default admin user, which can also optionally set the default admin users' password from an environment variable. When the user is deleted, the `initial-setup` flow used to configure authentik after the first installation becomes available again. authentik 2023.8.4 and 2023.10.2 fix this issue. As a workaround, ensure the default admin user (Username `akadmin`) exists and has a password set. It is recommended to use a very strong password for this user, and store it in a secure location like a password manager. It is also possible to deactivate the user to prevent any logins as akadmin.
Missing authentication for critical function in DAP-1880AC firmware version 1.21 and earlier allows a remote attacker to login to the device as an authenticated user without the access privilege via unspecified vectors.
An issue was discovered in Wavlink WN530HG4, Wavlink WN531G3, Wavlink WN533A8, and Wavlink WN551K1 affecting /cgi-bin/ExportAllSettings.sh where a crafted POST request returns the current configuration of the device, including the administrator password. No authentication is required. The attacker must perform a decryption step, but all decryption information is readily available.
An issue was discovered affecting a backup feature where a crafted POST request returns the current configuration of the device in cleartext, including the administrator password. No authentication is required. Affected devices: Wavlink WN575A3, Wavlink WN579G3, Wavlink WN531A6, Wavlink WN535G3, Wavlink WN530H4, Wavlink WN57X93, Wavlink WN572HG3, Wavlink WN575A4, Wavlink WN578A2, Wavlink WN579G3, Wavlink WN579X3, and Jetstream AC3000/ERAC3000
An issue was discovered where a page is exposed that has the current administrator password in cleartext in the source code of the page. No authentication is required in order to reach the page (a certain live_?.shtml page with the variable syspasswd). Affected Devices: Wavlink WN530HG4, Wavlink WN531G3, and Wavlink WN572HG3
This vulnerability allows remote attackers to execute arbitrary code on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the control service, which listens on TCP port 9999 by default. The issue results from the lack of authentication prior to allowing alterations to the system configuration. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-10493.
Motorola FX9500 devices allow remote attackers to read database files.
This vulnerability allows remote attackers to issue commands on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the EA-HTTP.exe process. The issue results from the lack of authentication prior to allowing alterations to the system configuration. An attacker can leverage this vulnerability to issue commands to the physical equipment controlled by the device. Was ZDI-CAN-10482.
Grundfos CIM 500 before v06.16.00 responds to unauthenticated requests for password storage files.
An issue was discovered in Electerm 1.3.22, allows attackers to execute arbitrary code via unverified request to electerms service.
In multiple managed switches by WAGO in different versions without authorization and with specially crafted packets it is possible to create users.
Vulnerability of access permissions not being strictly verified in the APPWidget module.Successful exploitation of this vulnerability may cause some apps to run without being authorized.
Trendnet AC2600 TEW-827DRU version 2.08B01 contains an authentication bypass vulnerability. It is possible for an unauthenticated, malicous actor to force the change of the admin password due to a hidden administrative command.
Incorrect Access Control in Emerson Smart Wireless Gateway 1420 4.6.59 allows remote attackers to obtain sensitive device information from the administrator console without authentication.
Piwigo v12.2.0 was discovered to contain an information leak via the action parameter in /admin/maintenance_actions.php.
Trendnet AC2600 TEW-827DRU version 2.08B01 improperly discloses information via redirection from the setup wizard. Authentication can be bypassed and a user may view information as Admin by manually browsing to the setup wizard and forcing it to redirect to the desired page.
The configuration backend of the web-based management can be used by unauthenticated users, although only authenticated users should be able to use the API. The vulnerability allows an unauthenticated attacker to read and set several device parameters that can lead to full compromise of the device.