A vulnerability has been identified in Automation License Manager 5 (All versions < 5.3.4.4). An attacker with network access to the device could send specially crafted network packets to determine whether or not a network port on another remote system is accessible or not. This allows the attacker to do basic network scanning using the victims machine. Successful exploitation requires a network connection to the affected device. The attacker does not need privileges, no user interaction is required. The impact is limited to determining whether or not a port on a target system is accessible by the affected device.
A OS Command Injection vulnerability exists in Node.js versions <14.20.0, <16.20.0, <18.5.0 due to an insufficient IsAllowedHost check that can easily be bypassed because IsIPAddress does not properly check if an IP address is invalid before making DBS requests allowing rebinding attacks.
A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.31), Mendix Applications using Mendix 8 (All versions < V8.18.18), Mendix Applications using Mendix 9 (All versions < V9.14.0), Mendix Applications using Mendix 9 (V9.12) (All versions < V9.12.2), Mendix Applications using Mendix 9 (V9.6) (All versions < V9.6.12). In case of access to an active user session in an application that is built with an affected version, it’s possible to change that user’s password bypassing password validations within a Mendix application. This could allow to set weak passwords.
A vulnerability has been identified in CoreShield One-Way Gateway (OWG) Software (All versions < V2.2). The default installation sets insecure file permissions that could allow a local attacker to escalate privileges to local administrator.
A vulnerability has been identified in SIMATIC MV400 family (All Versions < V7.0.6). An authenticated attacker could escalate privileges by sending specially crafted requests to the integrated webserver. The security vulnerability can be exploited by an attacker with network access to the device. Valid user credentials, but no user interaction are required. Successful exploitation compromises integrity and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2). The affected application consists of a web service that lacks proper access control for some of the endpoints. This could lead to unauthorized access to resources and potentially lead to code execution.
A vulnerability has been identified in Siemens License Server (SLS) (All versions < V4.3). The affected application searches for executable files in the application folder without proper validation. This could allow an attacker to execute arbitrary code with administrative privileges by placing a malicious executable in the same directory.
A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.27), Mendix Applications using Mendix 8 (All versions < V8.18.14), Mendix Applications using Mendix 9 (All versions < V9.12.0), Mendix Applications using Mendix 9 (V9.6) (All versions < V9.6.3). When querying the database, it is possible to sort the results using a protected field. With this an authenticated attacker could extract information about the contents of a protected field.
A vulnerability has been identified in SIMATIC WinCC OA UI for Android (All versions < V3.15.10), SIMATIC WinCC OA UI for iOS (All versions < V3.15.10). Insufficient limitation of CONTROL script capabilities could allow read and write access from one HMI project cache folder to other HMI project cache folders within the app's sandbox on the same mobile device. This includes HMI project cache folders of other configured WinCC OA servers. The security vulnerability could be exploited by an attacker who tricks an app user to connect to an attacker-controlled WinCC OA server. Successful exploitation requires user interaction and read/write access to the app's folder on a mobile device. The vulnerability could allow reading data from and writing data to the app's folder. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens confirms the security vulnerability and provides mitigations to resolve the security issue.
A vulnerability has been identified in PCS neo (Administration Console) (All versions < V3.1), TIA Portal (V15, V15.1 and V16). Manipulating certain files in specific folders could allow a local attacker to execute code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system.
A vulnerability has been identified in TIA Administrator (All versions < V3.0.6). The affected application allows low-privileged users to trigger installations by overwriting cache files and modifying the downloads path. This would allow an attacker to escalate privilege and exceute arbitrary code.
A vulnerability has been identified in Mendix Forgot Password Appstore module (All versions >= V3.3.0 < V3.5.1). In certain configurations of the affected product, a threat actor could use the sign up flow to hijack arbitrary user accounts.
A vulnerability has been identified in SIMATIC WinCC OA V3.14 and prior (All versions < V3.14-P021). Improper access control to a data point of the affected product could allow an unauthenticated remote user to escalate its privileges in the context of SIMATIC WinCC OA V3.14. This vulnerability could be exploited by an attacker with network access to port 5678/TCP of the SIMATIC WinCC OA V3.14 server. Successful exploitation requires no user privileges and no user interaction. This vulnerability could allow an attacker to compromise integrity and availability of the SIMATIC WinCC OA system. At the time of advisory publication no public exploitation of this vulnerability was known.
A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.29). When returning the result of a completed Microflow execution call the affected framework does not correctly verify, if the request was initially made by the user requesting the result. Together with predictable identifiers for Microflow execution calls, this could allow a malicious attacker to retrieve information about arbitrary Microflow execution calls made by users within the affected system.
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The webserver of an affected device is missing specific security headers. This could allow an remote attacker to extract confidential session information under certain circumstances.
A vulnerability has been identified in SINEC NMS (All versions >= V1.0.3 < V2.0), SINEC NMS (All versions < V1.0.3), SINEMA Server V14 (All versions). The affected software do not properly check privileges between users during the same web browser session, creating an unintended sphere of control. This could allow an authenticated low privileged user to achieve privilege escalation.
A vulnerability has been identified in SINUMERIK MC (All versions < V1.15 SP1), SINUMERIK ONE (All versions < V6.15 SP1). The sc SUID binary on affected devices provides several commands that are used to execute system commands or modify system files. A specific set of operations using sc could allow local attackers to escalate their privileges to root.
A vulnerability has been identified in Siemens 7KT PAC1200 data manager (7KT1260) in all versions < V2.03. The integrated web server (port 80/tcp) of the affected devices could allow an unauthenticated remote attacker to perform administrative operations over the network.
A vulnerability has been identified in DCA Vantage Analyzer (All versions < V4.5 are affected by CVE-2020-7590. In addition, serial numbers < 40000 running software V4.4.0 are also affected by CVE-2020-15797). Improper Access Control could allow an unauthenticated attacker to escape from the restricted environment (“kiosk mode”) and access the underlying operating system. Successful exploitation requires direct physical access to the system.
A vulnerability has been identified in License Management Utility (LMU) (All versions < V2.4). The lmgrd service of the affected application is executed with local SYSTEM privileges on the server while its configuration can be modified by local users. The vulnerability could allow a local authenticated attacker to execute arbitrary commands on the server with local SYSTEM privileges.
A vulnerability has been identified in SIMATIC CP 1604 (All versions), SIMATIC CP 1616 (All versions), SIMATIC CP 1623 (All versions), SIMATIC CP 1626 (All versions), SIMATIC CP 1628 (All versions). The kernel memory of affected devices is exposed to user-mode via direct memory access (DMA) which could allow a local attacker with administrative privileges to execute arbitrary code on the host system without any restrictions.
Siemens RUGGEDCOM ROS 3.8.0 through 4.1.x permanently enables the IP forwarding feature, which allows remote attackers to bypass a VLAN isolation protection mechanism via IP traffic.
A vulnerability has been identified in Climatix POL909 (AWB module) (All versions < V11.44), Climatix POL909 (AWM module) (All versions < V11.36). The handling of log files in the web application of affected devices contains an information disclosure vulnerability which could allow logged in users to access sensitive files.
A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.19), Mendix Applications using Mendix 8 (All versions < V8.17.0), Mendix Applications using Mendix 8 (V8.12) (All versions < V8.12.5), Mendix Applications using Mendix 8 (V8.6) (All versions < V8.6.9), Mendix Applications using Mendix 9 (All versions < V9.0.5). Authenticated, non-administrative users could modify their privileges by manipulating the user role under certain circumstances, allowing them to gain administrative privileges.
A vulnerability has been identified in Mendix Forgot Password Appstore module (All Versions < V3.2.1). The Forgot Password Marketplace module does not properly control access. An attacker could take over accounts.
A vulnerability in Siemens SICAM PAS (all versions before V8.09) could allow a remote attacker to cause a Denial of Service condition and potentially lead to unauthenticated remote code execution by sending specially crafted packets to port 19234/TCP.
A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC IT Production Suite (All versions < V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions < V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2), SIMATIC STEP 7 V5.X (All versions < V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (All versions < V14), SIMATIC WinCC (TIA Portal) Professional V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) Professional V14 (All versions < V14 SP1), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1), SIMATIC WinCC V7.0 SP2 and earlier versions (All versions < V7.0 SP2 Upd 12), SIMATIC WinCC V7.0 SP3 (All versions < V7.0 SP3 Upd 8), SIMATIC WinCC V7.2 (All versions < V7.2 Upd 14), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 11), SIMATIC WinCC V7.4 (All versions < V7.4 SP1), SIMIT V9.0 (All versions < V9.0 SP1), SINEMA Remote Connect Client (All versions < V1.0 SP3), SINEMA Server (All versions < V13 SP2), SOFTNET Security Client V5.0 (All versions), Security Configuration Tool (SCT) (All versions < V4.3 HF1), TeleControl Server Basic (All versions < V3.0 SP2), WinAC RTX 2010 SP2 (All versions), WinAC RTX F 2010 SP2 (All versions). Unquoted service paths could allow local Microsoft Windows operating system users to escalate their privileges if the affected products are not installed under their default path ("C:\Program Files\*" or the localized equivalent).
Sage DPW before 2024_12_001 is vulnerable to Incorrect Access Control. The implemented role-based access controls are not always enforced on the server side. Low-privileged Sage users with employee role privileges can create external courses for other employees, even though they do not have the option to do so in the user interface. To do this, a valid request to create a course simply needs to be modified, so that the current user ID in the "id" parameter is replaced with the ID of another user.
Improper access control in Odoo Community 15.0 and earlier and Odoo Enterprise 15.0 and earlier allows remote authenticated users to trigger the creation of demonstration data, including user accounts with known credentials.
Broken access control in NetAdmin 4.030319 returns data with functionalities on the endpoint that "assembles" the functionalities menus, the return of this call is not encrypted and as the system does not validate the session authorization, an attacker can copy the content of the browser of a user with greater privileges having access to the functionalities of the user that the code was copied.
Zitadel is an open source identity management platform. ZITADEL's user account deactivation mechanism did not work correctly with service accounts. Deactivated service accounts retained the ability to request tokens, which could lead to unauthorized access to applications and resources. Versions 2.62.1, 2.61.1, 2.60.2, 2.59.3, 2.58.5, 2.57.5, 2.56.6, 2.55.8, and 2.54.10 have been released which address this issue. Users are advised t upgrade. Users unable to upgrade may instead of deactivating the service account, consider creating new credentials and replacing the old ones wherever they are used. This effectively prevents the deactivated service account from being utilized. Be sure to revoke all existing authentication keys associated with the service account and to rotate the service account's password.
An issue was discovered in CALDERA 2.8.1. It does not properly segregate user privileges, resulting in non-admin users having access to read and modify configuration or other components that should only be accessible by admin users.
TestLink 1.9.20 is vulnerable to Incorrect Access Control in the TestPlan editing section. When a new TestPlan is created, an ID with an incremental value is automatically generated. Using the edit function you can change the tplan_id parameter to another ID. The application does not carry out a check on the user's permissions maing it possible to recover the IDs of all the TestPlans (even the administrative ones) and modify them even with minimal privileges.
HashiCorp Vault and Vault Enterprise 1.8.x through 1.8.4 may have an unexpected interaction between glob-related policies and the Google Cloud secrets engine. Users may, in some situations, have more privileges than intended, e.g., a user with read permission for the /gcp/roleset/* path may be able to issue Google Cloud service account credentials.
An issue was discovered in za-internet C-MOR Video Surveillance 5.2401. Due to improper or missing access control, low privileged users can use administrative functions of the C-MOR web interface. It was found out that different functions are only available to administrative users. However, access those functions is restricted via the web application user interface and not checked on the server side. Thus, by sending corresponding HTTP requests to the web server of the C-MOR web interface, low privileged users can also use administrative functionality, for instance downloading backup files or changing configuration settings.
i-Educar is free, fully online school management software that can be used by school secretaries, teachers, coordinators, and area managers. Prior to the 2.9 branch, an attacker with only minimal viewing privileges in the settings section is able to change their user type to Administrator (or another type with super-permissions) through a specifically crafted POST request to `/intranet/educar_usuario_cad.php`, modifying the `nivel_usuario_` parameter. The vulnerability occurs in the file located at `ieducar/intranet/educar_usuario_cad.php`, which does not check the user's current permission level before allowing changes. Commit c25910cdf11ab50e50162a49dd44bef544422b6e contains a patch for the issue.
TastyIgniter 3.7.6 contains an Incorrect Access Control vulnerability in the invoice() function within Orders.php which allows unauthorized users to access and generate invoices due to missing permission checks.
An issue has been discovered in GitLab CE/EE affecting all versions starting from 11.0 before 14.3.6, all versions starting from 14.4 before 14.4.4, all versions starting from 14.5 before 14.5.2. A permissions validation flaw allowed group members with a developer role to elevate their privilege to a maintainer on projects they import
Kamaji is the Hosted Control Plane Manager for Kubernetes. In versions 1.0.0 and earlier, Kamaji uses an "open at the top" range definition in RBAC for etcd roles leading to some TCPs API servers being able to read, write, and delete the data of other control planes. This vulnerability is fixed in edge-24.8.2.
Sielco PolyEco1000 is vulnerable to an attacker bypassing authorization and accessing resources behind protected pages. The application interface allows users to perform certain actions via HTTP requests without performing any validity checks to verify the requests.
Unspecified vulnerability in the PeopleSoft Enterprise SCM Services Procurement component in Oracle PeopleSoft Products 9.1 and 9.2 allows remote authenticated users to affect confidentiality and integrity via unknown vectors.
Improper Access Control Tampering Vulnerability using ImportAlert function which can lead to a Remote Code Execution (RCE) from the Alerts Settings page.
Nextcloud Server is a self hosted personal cloud system. A recipient of a share with read&share permissions could reshare the item with more permissions. It is recommended that the Nextcloud Server is upgraded to 26.0.13 or 27.1.8 or 28.0.4 and that the Nextcloud Enterprise Server is upgraded to 26.0.13 or 27.1.8 or 28.0.4.
IBM UrbanCode Deploy (UCD) 6.1 and 6.2 could allow an authenticated user to edit objects that they should not have access to due to improper access controls. IBM X-Force ID: 128691.
ZKTeco ZKBio CVSecurity 6.1.1 is vulnerable to Incorrect Access Control. An authenticated user, without the permissions of managing users, can create a new admin user.
In ZKTeco ZKBio CVSecurity v6.1.1_R and earlier (fixed in 6.1.3_R) an authenticated user can bypass password checks while exporting data from the application.
An issue in Insurance Management System v.1.0.0 and before allows a remote attacker to escalate privileges via a crafted POST request to /admin/core/new_staff.
The GamiPress WordPress plugin before 6.8.9's access control mechanism fails to properly restrict access to its settings, permitting Authors to manipulate requests and extend access to lower privileged users, like Subscribers, despite initial settings prohibiting such access. This vulnerability resembles broken access control, enabling unauthorized users to modify critical GamiPress WordPress plugin before 6.8.9 configurations.
Improper privilege validation vulnerability in COM Interface of Gallagher Command Centre Server allows authenticated unprivileged operators to retrieve sensitive information from the Command Centre Server. This issue affects: Gallagher Command Centre 8.50 versions prior to 8.50.2048 (MR3) ; 8.40 versions prior to 8.40.2063 (MR4); 8.30 versions prior to 8.30.1454 (MR4) ; 8.20 versions prior to 8.20.1291 (MR6); version 8.10 and prior versions.
Insecure permissions issue in EaseUS MobiMover 6.0.5 Build 21620 allows attackers to gain escalated privileges via use of crafted executable launched from the application installation directory.