Improper Input Validation vulnerability in the ABB SPIET800 and PNI800 module allows an attacker to cause the denial of service or make the module unresponsive.
Improper Input Validation vulnerability in the ABB SPIET800 and PNI800 module allows an attacker to cause the denial of service or make the module unresponsive.
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, ABB AbilityTM SCADAvantage versions 5.1 to 5.6.5, a weakness in validation of input exists that allows an attacker to block license handling by sending specially crafted messages to the CLS web service.
A S+ Operations and S+ Historian service is subject to a DoS by special crafted messages. An attacker might use this flaw to make it crash or even execute arbitrary code on the machine where the service is hosted.
ABB is aware of vulnerabilities in the product versions listed below. An update is available that resolves the reported vulnerabilities in the product versions under maintenance. An attacker who successfully exploited one or more of these vulnerabilities could cause the product to stop or make the product inaccessible. Numeric Range Comparison Without Minimum Check vulnerability in ABB Freelance controllers AC 700F (Controller modules), ABB Freelance controllers AC 900F (controller modules).This issue affects: Freelance controllers AC 700F: from 9.0;0 through V9.2 SP2, through Freelance 2013, through Freelance 2013SP1, through Freelance 2016, through Freelance 2016SP1, through Freelance 2019, through Freelance 2019 SP1, through Freelance 2019 SP1 FP1; Freelance controllers AC 900F: Freelance 2013, through Freelance 2013SP1, through Freelance 2016, through Freelance 2016SP1, through Freelance 2019, through Freelance 2019 SP1, through Freelance 2019 SP1 FP1.
ABB is aware of vulnerabilities in the product versions listed below. An update is available that resolves the reported vulnerabilities in the product versions under maintenance. An attacker who successfully exploited one or more of these vulnerabilities could cause the product to stop or make the product inaccessible. Stack-based Buffer Overflow vulnerability in ABB Freelance controllers AC 700F (conroller modules), ABB Freelance controllers AC 900F (controller modules).This issue affects: Â Freelance controllers AC 700F:Â from 9.0;0 through V9.2 SP2, through Freelance 2013, through Freelance 2013SP1, through Freelance 2016, through Freelance 2016SP1, through Freelance 2019 , through Freelance 2019 SP1, through Freelance 2019 SP1 FP1;Â Freelance controllers AC 900F:Â through Freelance 2013, through Freelance 2013SP1, through Freelance 2016, through Freelance 2016SP1, through Freelance 2019, through Freelance 2019 SP1, through Freelance 2019 SP1 FP1.
ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets.
Improper Handling of Exceptional Conditions, Improper Check for Unusual or Exceptional Conditions vulnerability in the ABB SPIET800 and PNI800 module that allows an attacker to cause the denial of service or make the module unresponsive.
A vulnerability exists in the HCI Modbus TCP function included in the product versions listed above. If the HCI Modbus TCP is en-abled and configured, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500, causing the receiving RTU500 CMU to reboot. The vulnerability is caused by the validation error in the length information carried in MBAP header in the HCI Modbus TCP function.
Missing Authentication for Critical Function vulnerability in ABB ABB AbilityTM zenon.This issue affects ABB AbilityTM zenon: from 7.50 through 14.
Stack-based Buffer Overflow vulnerability in ABB RMC-100, ABB RMC-100 LITE. When the REST interface is enabled by the user, and an attacker gains access to the control network, and user/password broker authentication is enabled, and CVE-2025-6074 is exploited, the attacker can overflow the buffer for username or password. This issue affects RMC-100: from 2105457-043 through 2105457-045; RMC-100 LITE: from 2106229-015 through 2106229-016.
Stack-based Buffer Overflow vulnerability in ABB RMC-100, ABB RMC-100 LITE. When the REST interface is enabled by the user, and an attacker gains access to the control network, and CVE-2025-6074 is exploited, the attacker can use the JSON configuration to overflow the date of expiration field.This issue affects RMC-100: from 2105457-043 through 2105457-045; RMC-100 LITE: from 2106229-015 through 2106229-016.
The vulnerabilities can be exploited to cause the web visualization component of the PLC to stop and not respond, leading to genuine users losing remote visibility of the PLC state. If a user attempts to login to the PLC while this vulnerability is exploited, the PLC will show an error state and refuse connections to Automation Builder. The execution of the PLC application is not affected by this vulnerability. This issue affects ABB AC500 V2 products with onboard Ethernet.
Fileszie Check vulnerabilities allow a malicious user to bypass size limits or overload to the product. Affected products: ABB ASPECT - Enterprise v3.08.02; NEXUS Series v3.08.02; MATRIX Series v3.08.02
ABB has internally identified a vulnerability in the ABB VPNI feature of the S+ Control API component which may be used by several Symphony Plus products (e.g., S+ Operations, S+ Engineering and S+ Analyst) This issue affects Symphony Plus S+ Operations: from 3..0;0 through 3.3 SP1 RU4, from 2.1;0 through 2.1 SP2 RU3, from 2.0;0 through 2.0 SP6 TC6; Symphony Plus S+ Engineering: from 2.1 through 2.3 RU3; Symphony Plus S+ Analyst: from 7.0.0.0 through 7.2.0.2.
Lack of adequate input/output validation for ABB eSOMS versions 4.0 to 6.0.2 might allow an attacker to attack such as stored cross-site scripting by storing malicious content in the database.
The HMISimulator component of ABB PB610 Panel Builder 600 versions 2.8.0.424 and earlier fails to validate the content-length field for HTTP requests, exposing HMISimulator to denial of service via crafted HTTP requests manipulating the content-length setting.
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, ABB AbilityTM SCADAvantage versions 5.1 to 5.6.5, a weakness in validation of input exists that allows an attacker to alter licenses assigned to the system nodes by sending specially crafted messages to the CLS web service.
A vulnerability in Base Software for SoftControl allows an attacker to insert and run arbitrary code in a computer running the affected product. This issue affects: .
Due to a lack of file length check, the HMIStudio component of ABB PB610 Panel Builder 600 versions 2.8.0.424 and earlier crashes when trying to load an empty *.JPR application file. An attacker with access to the file system might be able to cause application malfunction such as denial of service.
The TextEditor 2.0 in ABB CP400 Panel Builder versions 2.0.7.05 and earlier contain a vulnerability in the file parser of the Text Editor wherein the application doesn't properly prevent the insertion of specially crafted files which could allow arbitrary code execution.
ABB Panel Builder 800 all versions has an improper input validation vulnerability which may allow an attacker to insert and run arbitrary code on a computer where the affected product is used.
A validation issue was addressed with improved logic. This issue is fixed in iOS 18.4 and iPadOS 18.4, iPadOS 17.7.6, macOS Sequoia 15.4, macOS Sonoma 14.7.5, macOS Ventura 13.7.5, tvOS 18.4, visionOS 2.4, watchOS 11.4. A remote user may be able to cause a denial-of-service.
A vulnerability in the email message filtering feature of Cisco AsyncOS Software for Cisco Email Security Appliance (ESA) and Cisco Content Security Management Appliance (SMA) could allow an unauthenticated, remote attacker to cause repeated crashes in some internal processes that are running on the affected devices, resulting in a denial of service (DoS) condition. The vulnerability is due to insufficient input validation of email attachments. An attacker could exploit this vulnerability by sending an email message with a crafted attachment through an affected device. A successful exploit could allow the attacker to cause specific processes to crash repeatedly, resulting in the complete unavailability of both the Cisco Advanced Malware Protection (AMP) and message tracking features and in severe performance degradation while processing email. After the affected processes restart, the software resumes filtering for the same attachment, causing the affected processes to crash and restart again. A successful exploit could also allow the attacker to cause a repeated DoS condition. Manual intervention may be required to recover from this situation.
A vulnerability has been identified in SiNVR/SiVMS Video Server (All versions < V5.0.0), SiNVR/SiVMS Video Server (All versions >= V5.0.0 < V5.0.2). The streaming service (default port 5410/tcp) of the SiVMS/SiNVR Video Server contains a input validation vulnerability, that could allow an unauthenticated remote attacker to cause a Denial-of-Service condition by sending malformed HTTP requests.
illumos, as used in OmniOS Community Edition before r151030y, allows a kernel crash via an application with multiple threads calling sendmsg concurrently over a single socket, because uts/common/inet/ip/ip_attr.c mishandles conn_ixa dereferences.
The SIP module of some Huawei products have a denial of service (DoS) vulnerability. A remote attacker could exploit these three vulnerabilities by sending the specially crafted messages to the affected device. Due to the insufficient verification of the packets, successful exploit could allow the attacker to cause buffer overflow and dead loop, leading to DoS condition. Affected products can be found in https://www.huawei.com/en/psirt/security-advisories/huawei-sa-20200115-01-sip-en.
A vulnerability has been identified in SIPROTEC 4 and SIPROTEC Compact relays equipped with EN100 Ethernet communication modules (All versions). Specially crafted packets sent to port 50000/UDP of the EN100 Ethernet communication modules could cause a Denial-of-Service of the affected device. A manual reboot is required to recover the service of the device. At the time of advisory publication no public exploitation of this security vulnerability was known to Siemens.
A vulnerability in the IPv6 traffic processing of Cisco NX-OS Software could allow an unauthenticated, remote attacker to cause an unexpected restart of the netstack process on an affected device. The vulnerability is due to improper validation of IPv6 traffic sent through an affected device. An attacker could exploit this vulnerability by sending a malformed IPv6 packet through an affected device. A successful exploit could allow the attacker to cause a denial of service (DoS) condition while the netstack process restarts. A sustained attack could lead to a reboot of the device.
A vulnerability in the email message filtering feature of Cisco AsyncOS Software for Cisco Email Security Appliance (ESA) could allow an unauthenticated, remote attacker to cause the CPU utilization to increase to 100 percent, causing a denial of service (DoS) condition on an affected device. The vulnerability is due to improper handling of email messages that contain large attachments. An attacker could exploit this vulnerability by sending a malicious email message through the targeted device. A successful exploit could allow the attacker to cause a permanent DoS condition due to high CPU utilization. This vulnerability may require manual intervention to recover the ESA.
A vulnerability in the cryptographic driver for Cisco Adaptive Security Appliance Software (ASA) and Firepower Threat Defense (FTD) Software could allow an unauthenticated, remote attacker to cause the device to reboot unexpectedly. The vulnerability is due to incomplete input validation of a Secure Sockets Layer (SSL) or Transport Layer Security (TLS) ingress packet header. An attacker could exploit this vulnerability by sending a crafted TLS/SSL packet to an interface on the targeted device. An exploit could allow the attacker to cause the device to reload, which will result in a denial of service (DoS) condition. Note: Only traffic directed to the affected system can be used to exploit this vulnerability. This vulnerability affects systems configured in routed and transparent firewall mode and in single or multiple context mode. This vulnerability can be triggered by IPv4 and IPv6 traffic. A valid SSL or TLS session is required to exploit this vulnerability.
The SIP module of some Huawei products have a denial of service (DoS) vulnerability. A remote attacker could exploit these three vulnerabilities by sending the specially crafted messages to the affected device. Due to the insufficient verification of the packets, successful exploit could allow the attacker to cause buffer overflow and dead loop, leading to DoS condition. Affected products can be found in https://www.huawei.com/en/psirt/security-advisories/huawei-sa-20200115-01-sip-en.
OpenAirInterface V2.2.0 AMF crashes when it receives an NGAP message with invalid procedure code or invalid PDU-type. For example when the message specification requires InitiatingMessage but sent with successfulOutcome.
A missing nullptr-check in handle_ra_input can cause a nullptr-deref.
Pexip Infinity before 26 allows temporary remote Denial of Service (abort) because of missing call-setup input validation.
A vulnerability in the Network Address Translation 64 (NAT64) functions of Cisco IOS Software could allow an unauthenticated, remote attacker to cause either an interface queue wedge or a device reload. The vulnerability is due to the incorrect handling of certain IPv4 packet streams that are sent through the device. An attacker could exploit this vulnerability by sending specific IPv4 packet streams through the device. An exploit could allow the attacker to either cause an interface queue wedge or a device reload, resulting in a denial of service (DoS) condition.
Honeywell equIP series IP cameras Multiple equIP Series Cameras, A vulnerability exists in the affected products where a specially crafted HTTP packet request could result in a denial of service.
Improper Input Validation in GitHub repository pyload/pyload prior to 0.5.0b3.dev40.
A vulnerability in the Network-Based Application Recognition (NBAR) feature of Cisco IOS Software and Cisco IOS XE Software could allow an unauthenticated, remote attacker to cause an affected device to reload. This vulnerability are due to a parsing issue on DNS packets. An attacker could exploit this vulnerability by sending crafted DNS packets through routers that are running an affected version and have NBAR enabled. A successful exploit could allow the attacker to cause the affected device to reload, resulting in a denial of service (DoS) condition.
An attacker may use a specially crafted message to force Relion 650 series (versions 1.3.0.5 and prior) or Relion 670 series (versions 1.2.3.18, 2.0.0.11, 2.1.0.1 and prior) to reboot, which could cause a denial of service.
A vulnerability in the ISDN functions of Cisco IOS Software and Cisco IOS XE Software could allow an unauthenticated, remote attacker to cause the device to reload. The vulnerability is due to incorrect processing of specific values in the Q.931 information elements. An attacker could exploit this vulnerability by calling the affected device with specific Q.931 information elements being present. An exploit could allow the attacker to cause the device to reload, resulting in a denial of service (DoS) condition on an affected device.
The AsyncResponseWrapperImpl class in Apache Olingo versions 4.0.0 to 4.6.0 reads the Retry-After header and passes it to the Thread.sleep() method without any check. If a malicious server returns a huge value in the header, then it can help to implement a DoS attack.
A denial-of-service issue was discovered in the MQTT library in Arm Mbed OS 2017-11-02. The function readMQTTLenString() is called by the function MQTTDeserialize_publish() to get the length and content of the MQTT topic name. In the function readMQTTLenString(), mqttstring->lenstring.len is a part of user input, which can be manipulated. An attacker can simply change it to a larger value to invalidate the if statement so that the statements inside the if statement are skipped, letting the value of mqttstring->lenstring.data default to zero. Later, curn is accessed, which points to mqttstring->lenstring.data. On an Arm Cortex-M chip, the value at address 0x0 is actually the initialization value for the MSP register. It is highly dependent on the actual firmware. Therefore, the behavior of the program is unpredictable from this time on.
A vulnerability in the User Data Services (UDS) API of Cisco Unified Communications Manager (Unified CM) could allow an unauthenticated, remote attacker to cause a denial of service (DoS) condition on the management GUI. The vulnerability is due to improper validation of input parameters in the UDS API requests. An attacker could exploit this vulnerability by sending a crafted request to the UDS API of an affected device. A successful exploit could allow the attacker to make the A Cisco DB service quit unexpectedly, preventing admin access to the Unified CM management GUI. Manual intervention may be required to restore normal operation. Software versions 10.5, 11.5, 12.0, 12.5 are affected.
A vulnerability in the implementation of the Lightweight Directory Access Protocol (LDAP) feature in Cisco Adaptive Security Appliance (ASA) Software and Firepower Threat Defense (FTD) Software could allow an unauthenticated, remote attacker to cause an affected device to reload, resulting in a denial of service (DoS) condition. The vulnerabilities are due to the improper parsing of LDAP packets sent to an affected device. An attacker could exploit these vulnerabilities by sending a crafted LDAP packet, using Basic Encoding Rules (BER), to be processed by an affected device. A successful exploit could allow the attacker to cause the affected device to reload, resulting in a DoS condition.
A vulnerability in the Network-Based Application Recognition (NBAR) feature of Cisco IOS Software and Cisco IOS XE Software could allow an unauthenticated, remote attacker to cause an affected device to reload. This vulnerability is due to a parsing issue on DNS packets. An attacker could exploit these vulnerabilities by sending crafted DNS packets through routers that are running an affected version and have NBAR enabled. A successful exploit could allow the attacker to cause the affected device to reload, resulting in a denial of service (DoS) condition.
A vulnerability in the web-based management interface of Session Initiation Protocol (SIP) Software for Cisco IP Phone 8800 Series could allow an unauthenticated, remote attacker to cause high disk utilization, resulting in a denial of service (DoS) condition. The vulnerability exists because the affected software does not restrict the maximum size of certain files that can be written to disk. An attacker who has valid administrator credentials for an affected system could exploit this vulnerability by sending a crafted, remote connection request to an affected system. A successful exploit could allow the attacker to write a file that consumes most of the available disk space on the system, causing application functions to operate abnormally and leading to a DoS condition. This vulnerability affects Cisco IP Phone 8800 Series products running a SIP Software release prior to 12.5(1)SR1.
There is a Improper Input Validation vulnerability in Huawei Smartphone.Successful exploitation of this vulnerability will cause kernel crash.
A vulnerability in the TCP processing engine of Cisco Adaptive Security Appliance (ASA) Software and Cisco Firepower Threat Defense (FTD) Software could allow an unauthenticated, remote attacker to cause an affected device to reload, resulting in a denial of service (DoS) condition. The vulnerability is due to the improper handling of TCP traffic. An attacker could exploit this vulnerability by sending a specific sequence of packets at a high rate through an affected device. A successful exploit could allow the attacker to temporarily disrupt traffic through the device while it reboots.
A vulnerability in the web proxy functionality of Cisco AsyncOS Software for Cisco Web Security Appliance could allow an unauthenticated, remote attacker to cause a denial of service (DoS) condition on an affected device. The vulnerability is due to improper validation of HTTP and HTTPS requests. An attacker could exploit this vulnerability by sending a malformed HTTP or HTTPS request to an affected device. An exploit could allow the attacker to cause a restart of the web proxy process, resulting in a temporary DoS condition.