Fileszie Check vulnerabilities allow a malicious user to bypass size limits or overload to the product. Affected products: ABB ASPECT - Enterprise v3.08.02; NEXUS Series v3.08.02; MATRIX Series v3.08.02
ABB has internally identified a vulnerability in the ABB VPNI feature of the S+ Control API component which may be used by several Symphony Plus products (e.g., S+ Operations, S+ Engineering and S+ Analyst) This issue affects Symphony Plus S+ Operations: from 3..0;0 through 3.3 SP1 RU4, from 2.1;0 through 2.1 SP2 RU3, from 2.0;0 through 2.0 SP6 TC6; Symphony Plus S+ Engineering: from 2.1 through 2.3 RU3; Symphony Plus S+ Analyst: from 7.0.0.0 through 7.2.0.2.
Stack-based Buffer Overflow vulnerability in ABB RMC-100, ABB RMC-100 LITE. When the REST interface is enabled by the user, and an attacker gains access to the control network, and CVE-2025-6074 is exploited, the attacker can use the JSON configuration to overflow the date of expiration field.This issue affects RMC-100: from 2105457-043 through 2105457-045; RMC-100 LITE: from 2106229-015 through 2106229-016.
Stack-based Buffer Overflow vulnerability in ABB RMC-100, ABB RMC-100 LITE. When the REST interface is enabled by the user, and an attacker gains access to the control network, and user/password broker authentication is enabled, and CVE-2025-6074 is exploited, the attacker can overflow the buffer for username or password. This issue affects RMC-100: from 2105457-043 through 2105457-045; RMC-100 LITE: from 2106229-015 through 2106229-016.
ABB is aware of vulnerabilities in the product versions listed below. An update is available that resolves the reported vulnerabilities in the product versions under maintenance. An attacker who successfully exploited one or more of these vulnerabilities could cause the product to stop or make the product inaccessible. Numeric Range Comparison Without Minimum Check vulnerability in ABB Freelance controllers AC 700F (Controller modules), ABB Freelance controllers AC 900F (controller modules).This issue affects: Freelance controllers AC 700F: from 9.0;0 through V9.2 SP2, through Freelance 2013, through Freelance 2013SP1, through Freelance 2016, through Freelance 2016SP1, through Freelance 2019, through Freelance 2019 SP1, through Freelance 2019 SP1 FP1; Freelance controllers AC 900F: Freelance 2013, through Freelance 2013SP1, through Freelance 2016, through Freelance 2016SP1, through Freelance 2019, through Freelance 2019 SP1, through Freelance 2019 SP1 FP1.
Improper Input Validation vulnerability in the ABB SPIET800 and PNI800 module allows an attacker to cause the denial of service or make the module unresponsive.
Improper Handling of Exceptional Conditions, Improper Check for Unusual or Exceptional Conditions vulnerability in the ABB SPIET800 and PNI800 module that allows an attacker to cause the denial of service or make the module unresponsive.
Improper Input Validation vulnerability in the ABB SPIET800 and PNI800 module allows an attacker to cause the denial of service or make the module unresponsive.
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, ABB AbilityTM SCADAvantage versions 5.1 to 5.6.5, a weakness in validation of input exists that allows an attacker to block license handling by sending specially crafted messages to the CLS web service.
ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets.
The vulnerabilities can be exploited to cause the web visualization component of the PLC to stop and not respond, leading to genuine users losing remote visibility of the PLC state. If a user attempts to login to the PLC while this vulnerability is exploited, the PLC will show an error state and refuse connections to Automation Builder. The execution of the PLC application is not affected by this vulnerability. This issue affects ABB AC500 V2 products with onboard Ethernet.
A S+ Operations and S+ Historian service is subject to a DoS by special crafted messages. An attacker might use this flaw to make it crash or even execute arbitrary code on the machine where the service is hosted.
Improper Input Validation vulnerability in ABB 800xA, Control Software for AC 800M, Control Builder Safe, Compact Product Suite - Control and I/O, ABB Base Software for SoftControl allows an attacker to cause the denial of service.
ABB is aware of vulnerabilities in the product versions listed below. An update is available that resolves the reported vulnerabilities in the product versions under maintenance. An attacker who successfully exploited one or more of these vulnerabilities could cause the product to stop or make the product inaccessible. Stack-based Buffer Overflow vulnerability in ABB Freelance controllers AC 700F (conroller modules), ABB Freelance controllers AC 900F (controller modules).This issue affects: Freelance controllers AC 700F: from 9.0;0 through V9.2 SP2, through Freelance 2013, through Freelance 2013SP1, through Freelance 2016, through Freelance 2016SP1, through Freelance 2019 , through Freelance 2019 SP1, through Freelance 2019 SP1 FP1; Freelance controllers AC 900F: through Freelance 2013, through Freelance 2013SP1, through Freelance 2016, through Freelance 2016SP1, through Freelance 2019, through Freelance 2019 SP1, through Freelance 2019 SP1 FP1.
ABB MicroSCADA Pro SYS600 version 9.3 suffers from an instance of CWE-306: Missing Authentication for Critical Function.
The web server in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway allows access to different endpoints of the application without authenticating by accessing a specific uniform resource locator (URL) , violating the access-control (ACL) rules. This issue allows obtaining sensitive information that may aid in further attacks and privilege escalation.
ABB eSOMS versions 4.0 to 6.0.3 use ASP.NET Viewstate without Message Authentication Code (MAC). Alterations to Viewstate might thus not be noticed.
A Missing Authentication vulnerability in RobotWare for the OmniCore robot controller allows an attacker to read and modify files on the robot controller if the attacker has access to the Connected Services Gateway Ethernet port.
Missing Authentication for Critical Function vulnerability in ABB ALS-mini-s4 IP, ABB ALS-mini-s8 IP.This issue affects . All firmware versions with the Serial Number from 2000 to 5166
Missing authentication for critical function vulnerability in ABB AWIN GW100 rev.2, ABB AWIN GW120.This issue affects AWIN GW100 rev.2: 2.0-0, 2.0-1; AWIN GW120: 1.2-0, 1.2-1.
Missing authentication for critical function vulnerability in ABB AWIN GW100 rev.2, ABB AWIN GW120.This issue affects AWIN GW100 rev.2: 2.0-0, 2.0-1; AWIN GW120: 1.2-0, 1.2-1.
The ASPECT system allows users to bypass authentication. This issue affects all versions of ASPECT
VPN Browser+ 1.1.0.0 contains a denial of service vulnerability that allows unauthenticated attackers to crash the application by submitting oversized input through the search functionality. Attackers can paste a large buffer of characters into the search bar to trigger an unhandled exception that terminates the application.
An exploitable denial-of-service vulnerability exists in the UDPRelay functionality of Shadowsocks-libev 3.3.2. When utilizing a Stream Cipher and a local_address, arbitrary UDP packets can cause a FATAL error code path and exit. An attacker can send arbitrary UDP packets to trigger this vulnerability.
Core FTP 2.0 build 653 contains a denial of service vulnerability in the PBSZ command that allows unauthenticated attackers to crash the service by sending a malformed command with an oversized buffer. Attackers can send a PBSZ command with a payload exceeding 211 bytes to trigger an access violation and crash the FTP server process.
Vulnerability in the Oracle WebLogic Server product of Oracle Fusion Middleware (component: Core). Supported versions that are affected are 14.1.1.0.0 and 14.1.2.0.0. Easily exploitable vulnerability allows unauthenticated attacker with network access via HTTP/2 to compromise Oracle WebLogic Server. Successful attacks of this vulnerability can result in unauthorized ability to cause a hang or frequently repeatable crash (complete DOS) of Oracle WebLogic Server. CVSS 3.1 Base Score 7.5 (Availability impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).
D-Link D-View shutdown_coreserver Missing Authentication Denial-of-Service Vulnerability. This vulnerability allows remote attackers to create a denial-of-service condition on affected installations of D-Link D-View. Authentication is not required to exploit this vulnerability. The specific flaw exists within the shutdown_coreserver action. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to create a denial-of-service condition on the system. Was ZDI-CAN-19572.
Western Digital WD My Book Live (2.x and later) and WD My Book Live Duo (all versions) have an administrator API that can perform a system factory restore without authentication, as exploited in the wild in June 2021, a different vulnerability than CVE-2018-18472.
Vulnerability in the Oracle Financial Services Analytical Applications Infrastructure product of Oracle Financial Services Applications (component: System Configuration). Supported versions that are affected are 8.0.7.9, 8.0.8.7 and 8.1.2.5. Easily exploitable vulnerability allows unauthenticated attacker with network access via HTTP to compromise Oracle Financial Services Analytical Applications Infrastructure. Successful attacks of this vulnerability can result in unauthorized ability to cause a hang or frequently repeatable crash (complete DOS) of Oracle Financial Services Analytical Applications Infrastructure. CVSS 3.1 Base Score 7.5 (Availability impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).
The Chaos Controller Manager in Chaos Mesh exposes a GraphQL debugging server without authentication to the entire Kubernetes cluster, which provides an API to kill arbitrary processes in any Kubernetes pod, leading to cluster-wide denial of service.
One of the usage insights HTTP API endpoints in Grafana Enterprise 6.x before 6.7.6, 7.x before 7.3.10, and 7.4.x before 7.4.5 is accessible without any authentication. This allows any unauthenticated user to send an unlimited number of requests to the endpoint, leading to a denial of service (DoS) attack against a Grafana Enterprise instance.
The Web Management of TP-Link TP-SG105E V4 1.0.0 Build 20181120 devices allows an unauthenticated attacker to reboot the device via a reboot.cgi request.
A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server could trigger a Denial-of-Service condition by sending specifically crafted packets to port 7061/tcp. This vulnerability is independent from CVE-2019-18310. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
In D-link DIR-816 A2_v1.10CNB04.img,the network can be reset without authentication via /goform/setMAC.
A denial of service vulnerability exists in the Modbus TCP and Modbus RTU over TCP USB Function functionality of Socomec DIRIS Digiware M-70 1.6.9. A specially crafted network packet can lead to a denial of service. An attacker can send an unauthenticated packet to trigger this vulnerability.This vulnerability is specific to the malicious message sent via Modbus TCP over port 502.
A denial of service vulnerability exists in the Modbus TCP and Modbus RTU over TCP USB Function functionality of Socomec DIRIS Digiware M-70 1.6.9. A specially crafted network packet can lead to a denial of service. An attacker can send an unauthenticated packet to trigger this vulnerability.This vulnerability is specific to the malicious message sent via Modbus RTU over TCP on port 503.
An incorrect API discovered in Signify Wiz Connected 1.9.1 allows attackers to remotely launch a DoS on Wiz devices only requiring the MAC address.
A denial of service vulnerability exists in the Modbus TCP and Modbus RTU over TCP functionality of Socomec DIRIS Digiware M-70 1.6.9. A specially crafted series of network requests can lead to a denial of service. An attacker can send a sequence of unauthenticated packets to trigger this vulnerability.An attacker can trigger this denial-of-service condition by sending a sequence of Modbus RTU over TCP messages to port 503 using the Write Single Register function code (6). The attack sequence begins with a message to register 58112 with a value of 1000, indicating that a configuration change will follow. Next, a message is sent to register 29440 with a value corresponding to the new Modbus address to be configured. Finally, a message to register 57856 with a value of 161 commits the configuration change. After this configuration change, the device will be in a denial-of-service state.
The reminder module lacks an authentication mechanism for broadcasts received. Successful exploitation of this vulnerability may affect availability.
In Fibaro Home Center 2 and Lite devices with firmware version 4.600 and older an internal management service is accessible on port 8000 and some API endpoints could be accessed without authentication to trigger a shutdown, a reboot or a reboot into recovery mode.
A denial of service vulnerability exists in the Modbus TCP and Modbus RTU over TCP functionality of Socomec DIRIS Digiware M-70 1.6.9. A specially crafted series of network requests can lead to a denial of service. An attacker can send a sequence of unauthenticated packets to trigger this vulnerability.An attacker can trigger this denial-of-service condition by sending a sequence of Modbus TCP messages to port 502 using the Write Single Register function code (6). The attack sequence begins with a message to register 58112 with a value of 1000, indicating that a configuration change will follow. Next, a message is sent to register 29440 with a value corresponding to the new Modbus address to be configured. Finally, a message to register 57856 with a value of 161 commits the configuration change. After this configuration change, the device will be in a denial-of-service state.
A denial of service vulnerability exists in the Modbus TCP and Modbus RTU over TCP functionality of Socomec DIRIS Digiware M-70 1.6.9. A specially crafted series of network requests can lead to a denial of service. An attacker can send a sequence of unauthenticated packets to trigger this vulnerability.An attacker can trigger this denial-of-service condition by sending a single Modbus TCP message to port 502 using the Write Single Register function code (6) to write the value 1 to register 4352. This action changes the Modbus address to 15. After this message is sent, the device will be in a denial-of-service state.
A denial of service vulnerability exists in the Modbus TCP and Modbus RTU over TCP functionality of Socomec DIRIS Digiware M-70 1.6.9. A specially crafted series of network requests can lead to a denial of service. An attacker can send a sequence of unauthenticated packets to trigger this vulnerability.An attacker can trigger this denial-of-service condition by sending a single Modbus TCP message to port 503 using the Write Single Register function code (6) to write the value 1 to register 4352. This action changes the Modbus address to 15. After this message is sent, the device will be in a denial-of-service state.
free5GC is an open-source implementation of the 5G core network. Prior to 4.2.2, free5GC's SMF mounts the UPI management route group without inbound OAuth2 middleware. The POST /upi/v1/upNodesLinks create-or-update handler accepts attacker-controlled JSON and passes it directly into UpNodesFromConfiguration(), which calls logger.InitLog.Fatalf(...) on several validation failures. One confirmed path is the UE-IP-pool overlap check: a single unauthenticated POST that adds a new UPF whose pool overlaps an existing UPF terminates the entire SMF process (docker ps shows Exited (1)), not just the goroutine. This vulnerability is fixed in 4.2.2.
In Apache NiFi 1.0.0 to 1.11.4, the NiFi download token (one-time password) mechanism used a fixed cache size and did not authenticate a request to create a download token, only when attempting to use the token to access the content. An unauthenticated user could repeatedly request download tokens, preventing legitimate users from requesting download tokens.
Memory Allocation with Excessive Size Value, Allocation of Resources Without Limits or Throttling, Missing Authentication for Critical Function vulnerability in Apache IoTDB. When pipe_air_gap_receiver_enabled=true, the IoTDB AirGap pipe receiver accepts raw TCP connections on port 9780 with no authentication. The readLength method reads an attacker-controlled 32-bit integer from the socket and readData passes it directly to new byte[length] with no upper-bound check. An unauthenticated attacker can cause the JVM to attempt an allocation of up to 2,147,483,647 bytes per connection, exhausting heap memory and crashing or severely degrading the DataNode process. This issue affects Apache IoTDB: from 1.0.0 before 2.0.10. Users are recommended to upgrade to version 2.0.10, which fixes the issue.
AVE DOMINAplus <=1.10.x suffers from an unauthenticated reboot command execution. Attackers can exploit this issue to cause a denial of service scenario.
An issue in the component tpi_systool_handle(0) (/goform/SysToolRestoreSet) of Tenda W6-S v1.0.0.4(510) allows unauthenticated attackers to arbitrarily reboot the device.
NLTK (Natural Language Toolkit) is a suite of open source Python modules, data sets, and tutorials supporting research and development in Natural Language Processing. In versions 3.9.3 and prior, `nltk.app.wordnet_app` allows unauthenticated remote shutdown of the local WordNet Browser HTTP server when it is started in its default mode. A simple `GET /SHUTDOWN%20THE%20SERVER` request causes the process to terminate immediately via `os._exit(0)`, resulting in a denial of service. Commit bbaae83db86a0f49e00f5b0db44a7254c268de9b patches the issue.
Hermes Agent before 0.16.0 contains a DNS rebinding vulnerability in WebSocket endpoints that allows remote attackers to bypass Host and Origin validation. FastAPI HTTP middleware does not execute for WebSocket upgrade requests on /api/pty, /api/ws, /api/pub, and /api/events endpoints, enabling attackers to exploit DNS rebinding and inject malicious commands or read terminal output.