A cleartext transmission of sensitive information vulnerability exists in Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS. he integrated web server (Port 80/443/TCP) of the affected devices could allow remote attackers to discover an administrative account. If default on device, it is not using a SSL in settings and if multiple request of the page "Access Control" (IP-address device/ups/pas_cont.htm) account data will be sent in cleartext
Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 allows remote attackers to read database records by leveraging access to the guest account.
A CWE-665: Improper Initialization vulnerability exists that could cause information exposure when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
A CWE-862: Missing Authorization vulnerability exists that could cause information exposure when an attacker sends a specific message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
A CWE-326: Inadequate Encryption Strength vulnerability exists that could cause non-encrypted communication with the server when outdated versions of the ViewX client are used. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could cause Sensitive data such as login credentials being exposed when a Network is sniffed. Affected Product: Conext� ComBox (All Versions)
An exposure of sensitive information vulnerability exists in Schneider Electric's Pelco VideoXpert Enterprise versions 2.0 and prior. Using a directory traversal attack, an unauthorized person can view web server files.
A Violation of Secure Design Principles issue was discovered in Schneider Electric Modicon Modbus Protocol. The Modicon Modbus protocol has a session-related weakness making it susceptible to brute-force attacks.
A CWE-521: Weak Password Requirements vulnerability exists in Easergy Builder (Version 1.4.7.2 and older) which could allow an attacker to compromise a user account.
Directory traversal vulnerability in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier allows remote attackers to read arbitrary files via unspecified vectors.
A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions), which could cause the disclosure of information when transferring applications to the controller using Modbus TCP protocol.
A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading variables in the controller using Modbus.
A CWE-798: Use of Hardcoded Credentials vulnerability exists in Modicon Controllers (All versions of the following CPUs and Communication Module product references listed in the Security Notifications), which could cause the disclosure of FTP hardcoded credentials when using the Web server of the controller on an unsecure network.
A CWE-863: Incorrect Authorization vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow the file system to access the wrong file.
A CWE-669: Incorrect Resource Transfer Between Spheres vulnerability exists that could cause data exfiltration and unauthorized access when accessing a malicious website. Affected Product: spaceLYnk (V2.6.1 and prior), Wiser for KNX (V2.6.1 and prior), fellerLYnk (V2.6.1 and prior)
A CWE-759: Use of a One-Way Hash without a Salt vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could lead an attacker to get knowledge of charging station user account credentials using dictionary attacks techniques.
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause disclosure of arbitrary files being read in the context of the user running IGSS, due to missing validation of user supplied data in network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)
A CWE-319: Cleartext transmission of sensitive information vulnerability exists in PowerLogic ION7400, ION7650, ION7700/73xx, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause disclosure of user credentials when a malicious actor intercepts Telnet network traffic between a user and the device.
A CWE-425: Direct Request ('Forced Browsing') vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause disclosure of sensitive data when sending a specially crafted request to the controller over HTTP.
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could allow an attacker to access the system with elevated privileges when a privileged account clicks on a malicious URL that compromises the security token. Affected Products: AP7xxxx and AP8xxx with NMC2 (V6.9.6 or earlier), AP7xxx and AP8xxx with NMC3 (V1.1.0.3 or earlier), and APDU9xxx with NMC3 (V1.0.0.28 or earlier)
A CWE-200: Information Exposure vulnerability exists that could cause the exposure of sensitive information stored on the memory of the controller when communicating over the Modbus TCP protocol. Affected Products: Modicon M340 CPU (part numbers BMXP34*) (Versions prior to V3.30), Modicon M580 CPU (part numbers BMEP* and BMEH*) (Versions prior to SV3.20), Modicon MC80 (BMKC80) (Versions prior to V1.6), Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S) (All Versions), Modicon Momentum MDI (171CBU*) (Versions prior to V2.3), Legacy Modicon Quantum (All Versions)
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists in Modicon M221 (all references, all versions) that could allow non sensitive information disclosure when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller.
The vulnerability exists within error.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. System information is returned to the attacker that contains sensitive data.
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause information disclosure when specific messages are sent to the server over the database server TCP port. Affected Products: EcoStruxure Geo SCADA Expert 2019 - 2021 (formerly known as ClearSCADA) (Versions prior to October 2022)
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 store cleartext OPC User credentials in a configuration file, which allows local users to obtain sensitive information by reading this file.
CWE-200: Information Exposure vulnerability exists that could cause disclosure of credentials when a specially crafted message is sent to the device.
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 transmit cleartext credentials, which allows remote attackers to obtain sensitive information by sniffing the network.
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 rely on a hardcoded cleartext password to control read access to Project files and Project Configuration files, which makes it easier for local users to obtain sensitive information by discovering this password.
Information Exposure vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause information to be exposed when an unauthorized file is uploaded.
Information Exposure vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause a device to be compromised when it is first configured.
A CWE-200: Information Exposure vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could cause disclosure of encrypted credentials when consulting the maintenance report.
A CWE-200: Information Exposure vulnerability exists in Easergy T300 with firmware V2.7.1 and older that exposes sensitive information to an actor not explicitly authorized to have access to that information.
A CWE-200: Information Exposure vulnerability exists which could allow a session hijack when the door panel is communicating with the door. Affected Product: Ritto Wiser Door (All versions)
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exist in AccuSine PCS+ / PFV+ (Versions prior to V1.6.7) and AccuSine PCSn (Versions prior to V2.2.4) that could allow an authenticated attacker to access the device via FTP protocol.
The web portal interface in Citrix Access Gateway (aka Citrix Advanced Access Control) before Advanced Edition 4.5 HF1 places a session ID in the URL, which allows context-dependent attackers to hijack sessions by reading "residual information", including the a referer log, browser history, or browser cache.
A Disclosure of Sensitive Information vulnerability in HPE SiteScope version v11.2x, v11.3x was found.
Certain NETGEAR devices are affected by disclosure of sensitive information. This affects EAX80 before 1.0.1.62, EX7000 before 1.0.1.104, R6120 before 1.0.0.76, R6220 before 1.1.0.110, R6230 before 1.1.0.110, R6260 before 1.1.0.78, R6850 before 1.1.0.78, R6350 before 1.1.0.78, R6330 before 1.1.0.78, R6800 before 1.2.0.76, R6900v2 before 1.2.0.76, R6700v2 before 1.2.0.76, R7000 before 1.0.11.116, R6900P before 1.3.3.140, R7000P before 1.3.3.140, R7200 before 1.2.0.76, R7350 before 1.2.0.76, R7400 before 1.2.0.76, R7450 before 1.2.0.76, AC2100 before 1.2.0.76, AC2400 before 1.2.0.76, AC2600 before 1.2.0.76, R7900 before 1.0.4.38, R7960P before 1.4.1.66, R8000 before 1.0.4.68, R7900P before 1.4.1.66, R8000P before 1.4.1.66, RAX15 before 1.0.2.82, RAX20 before 1.0.2.82, RAX200 before 1.0.3.106, RAX45 before 1.0.2.72, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, and RAX80 before 1.0.3.106.
CA Identity Manager r12.6 to r12.6 SP8, 14.0, and 14.1 allows remote attackers to potentially identify passwords of locked accounts through an exhaustive search.
IBM Flex System Manager (FSM) 1.1 through 1.3 before 1.3.2.0 allows remote attackers to enumerate user accounts via unspecified vectors.
Certain NETGEAR devices are affected by disclosure of sensitive information. This affects R7000 before 1.0.11.110, R7900 before 1.0.4.30, R8000 before 1.0.4.62, RS400 before 1.5.1.80, R6400v2 before 1.0.4.102, R7000P before 1.3.2.126, R6700v3 before 1.0.4.102, and R6900P before 1.3.2.126.
The Comcast firmware on Cisco DPC3939 (firmware version dpc3939-P20-18-v303r20421746-170221a-CMCST) devices allows remote attackers to compute password-of-the-day values via unspecified vectors.
The Comcast firmware on Cisco DPC3939 (firmware version dpc3939-P20-18-v303r20421733-160420a-CMCST); Cisco DPC3939 (firmware version dpc3939-P20-18-v303r20421746-170221a-CMCST); Cisco DPC3939B (firmware version dpc3939b-v303r204217-150321a-CMCST); Cisco DPC3941T (firmware version DPC3941_2.5s3_PROD_sey); and Arris TG1682G (eMTA&DOCSIS version 10.0.132.SIP.PC20.CT, software version TG1682_2.2p7s2_PROD_sey) devices does not include the HTTPOnly flag in a Set-Cookie header for administration applications, which makes it easier for remote attackers to obtain potentially sensitive information via script access to cookies.
Microsoft SQL Server Analysis Services in Microsoft SQL Server 2012, Microsoft SQL Server 2014, and Microsoft SQL Server 2016 allows an information disclosure vulnerability when it improperly enforces permissions, aka "Microsoft SQL Server Analysis Services Information Disclosure Vulnerability".
The login function in Softaculous Webuzo before 2.1.4 provides different error messages for invalid authentication attempts depending on whether the user account exists, which allows remote attackers to enumerate usernames via a series of requests.
The Comcast firmware on Cisco DPC3939 (firmware version dpc3939-P20-18-v303r20421733-160420a-CMCST) and DPC3939 (firmware version dpc3939-P20-18-v303r20421746-170221a-CMCST) devices allows remote attackers to discover a CM MAC address by sniffing Wi-Fi traffic and performing simple arithmetic calculations.
The Comcast firmware on Cisco DPC3939 (firmware version dpc3939-P20-18-v303r20421733-160420a-CMCST); Cisco DPC3939 (firmware version dpc3939-P20-18-v303r20421746-170221a-CMCST); Cisco DPC3939B (firmware version dpc3939b-v303r204217-150321a-CMCST); Cisco DPC3941T (firmware version DPC3941_2.5s3_PROD_sey); and Arris TG1682G (eMTA&DOCSIS version 10.0.132.SIP.PC20.CT, software version TG1682_2.2p7s2_PROD_sey) devices does not set the secure flag for cookies in an https session to an administration application, which makes it easier for remote attackers to capture these cookies by intercepting their transmission within an http session.
IDM 4.6 Identity Applications prior to 4.6.2.1 may expose sensitive information.
Emerson Dixell XWEB-500 products are affected by information disclosure via directory listing. A potential attacker can use this misconfiguration to access all the files in the remote directories. Note: the product has not been supported since 2018 and should be removed or replaced
The Google News and Weather application before 3.3.1 for Android allows remote attackers to read OAuth tokens by sniffing the network and leveraging the lack of SSL.
A Remote Disclosure of Information vulnerability in HPE Intelligent Management Center (iMC) PLAT version 7.3 E0504P2 was found.