An issue was discovered in Schneider Electric Wonderware Historian 2014 R2 SP1 P01 and earlier. Wonderware Historian creates logins with default passwords, which can allow a malicious entity to compromise Historian databases. In some installation scenarios, resources beyond those created by Wonderware Historian may be compromised as well.
A CWE-306: Missing Authentication for Critical Function The software does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)
A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists that could cause remote code execution when the attacker uploads a malicious JSP file. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)
On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an SSH login can succeed with hardcoded default credentials (if the device is in the uncommissioned state).
CWE-200: Information Exposure vulnerability exists that could cause disclosure of credentials when a specially crafted message is sent to the device.
CWE-787: Out-of-bounds Write vulnerability exists that could result in an authentication bypass when sending a malformed POST request and particular configuration parameters are set.
An authorization bypass vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. Requests to CGI functions allow malicious users to bypass authorization.
In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, a buffer overflow vulnerability exist in cgi program "set".
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to bypass authentication and get the administrator privileges.
A Permissions, Privileges, and Access Control vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to overwrite the original password with their password. If an attacker exploits this vulnerability and overwrite the password, the attacker can upload the original program from the PLC.
A Credentials Management CWE-255 vulnerability exists in the APC UPS Network Management Card 2 AOS v6.5.6, which could cause Remote Monitoring Credentials to be viewed in plaintext when Remote Monitoring is enabled, and then disabled.
A SQL Injection (CWE-89) vulnerability exists in U.motion Builder software version 1.3.4 which could cause unwanted code execution when an improper set of characters is entered.
A CWE-501: Trust Boundary Violation vulnerability on connection to the Controller exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum and Modicon Premium which could cause unauthorized access by conducting a brute force attack on Modbus protocol to the controller.
A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service or potential code execution by overwriting configuration settings of the controller over Modbus.
In Schneider Electric Evlink Charging Station versions prior to v3.2.0-12_v1, the Web Interface has an issue that may allow a remote attacker to gain administrative privileges without properly authenticating remote users.
A buffer overflow vulnerability exist in the web-based GUI of Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to execute arbitrary code.
An unrestricted Upload of File with Dangerous Type vulnerability exists on numerous methods of the IIoT Monitor 3.1.38 software that could allow upload and execution of malicious files.
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to bypass authentication and gain administrator privileges because the use of hardcoded credentials.
In Schneider Electric U.motion Builder software versions prior to v1.3.4, a remote command injection allows authentication bypass.
A CWE-290: Authentication Bypass by Spoofing vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause an elevation of privilege by conducting a brute force attack on Modbus parameters sent to the controller.
Buffer overflow in an unspecified DLL in Schneider Electric Pelco DS-NVs before 7.8.90 allows remote attackers to execute arbitrary code via unspecified vectors.
Stack-based buffer overflow in an unspecified DLL file in a DTM development kit in Schneider Electric Unity Pro, SoMachine, SoMove, SoMove Lite, Modbus Communication Library 2.2.6 and earlier, CANopen Communication Library 1.0.2 and earlier, EtherNet/IP Communication Library 1.0.0 and earlier, EM X80 Gateway DTM (MB TCP/SL), Advantys DTM for OTB, Advantys DTM for STB, KINOS DTM, SOLO DTM, and Xantrex DTMs allows remote attackers to execute arbitrary code via unspecified vectors.
An Information Management Error vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to replay authentication sequences. If an attacker exploits this vulnerability and connects to a Modicon M221, the attacker can upload the original program from the PLC.
A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Including all Unity Pro versions (former name of EcoStruxure Control Expert) (V15.0 SP1 and prior), EcoStruxure Process Expert, Including all versions of EcoStruxure Hybrid DCS (former name of EcoStruxure Process Expert) (V2021 and prior), Modicon M340 CPU (part numbers BMXP34*) (V3.40 and prior), Modicon M580 CPU (part numbers BMEP* and BMEH*) (V3.20 and prior).
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted setting value messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)
A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection'), reflective DLL, vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior to V3.10), which, if exploited, could allow attackers to transfer malicious code to the controller.
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in SFAPV9601 - APC Easy UPS On-Line Software (V2.0 and earlier) when accessing a vulnerable method of `FileUploadServlet` which may lead to uploading executable files to non-specified directories.
A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause unauthenticated command execution in the controller when sending special HTTP requests.
CWE-287: Improper Authentication vulnerability exists which could cause the execution of commands on the webserver without authentication when sending specially crafted HTTP requests.
A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could cause brute force attacks to take over the admin account when the product does not implement a rate limit mechanism on the admin authentication form. Affected Products: Conext™ ComBox (All Versions)
A CWE-20: Improper Input Validation vulnerability exists that could cause a Denial of Service when a crafted packet is sent to the controller over network port 1105/TCP. Affected Product: Modicon M218 Logic Controller (V5.1.0.6 and prior)
A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service via a specially crafted HTTP packet
Improper Input Validation vulnerability exists in Modicon M241/M251 logic controllers firmware prior to V5.1.9.1 that could cause denial of service when specific crafted requests are sent to the controller over HTTP.
A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code execution when the user visits a page containing the injected payload. This CVE is unique from CVE-2021-22827. Affected Product: EcoStruxure� Power Monitoring Expert 9.0 and prior versions
A CWE-20: Improper Input Validation vulnerability exists that could cause denial of service of the device when an attacker sends a specially crafted HTTP request to the web server of the device. Affected Product: Modicon M340 CPUs: BMXP34 (Versions prior to V3.40), Modicon M340 X80 Ethernet Communication Modules: BMXNOE0100 (H), BMXNOE0110 (H), BMXNOC0401, BMXNOR0200H RTU (All Versions), Modicon Premium Processors with integrated Ethernet (Copro): TSXP574634, TSXP575634, TSXP576634 (All Versions), Modicon Quantum Processors with Integrated Ethernet (Copro): 140CPU65xxxxx (All Versions), Modicon Quantum Communication Modules: 140NOE771x1, 140NOC78x00, 140NOC77101 (All Versions), Modicon Premium Communication Modules: TSXETY4103, TSXETY5103 (All Versions)
A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code execution when the user visits a page containing the injected payload. This CVE is unique from CVE-2021-22826. Affected Product: EcoStruxure� Power Monitoring Expert 9.0 and prior versions
A CWE-20: Improper Input Validation vulnerability exists that could cause potential remote code execution when an attacker is able to intercept and modify a request on the same network or has configuration access to an ION device on the network. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
A CWE-20: Improper Input Validation vulnerability exists that could allow the product to be maliciously manipulated when the user is tricked into performing certain actions on a webpage. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
A CWE-20: Improper Input Validation vulnerability exists in Easergy T300 (Firmware version 1.5.2 and older) which could allow an attacker to disable the webserver service on the device when specially crafted network packets are sent.
In Schneider Electric ClearSCADA 2014 R1 (build 75.5210) and prior, 2014 R1.1 (build 75.5387) and prior, 2015 R1 (build 76.5648) and prior, and 2015 R2 (build 77.5882) and prior, an attacker with network access to the ClearSCADA server can send specially crafted sequences of commands and data packets to the ClearSCADA server that can cause the ClearSCADA server process and ClearSCADA communications driver processes to terminate. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).
A CWE-20: Improper Input Validation vulnerability exists that could allow an unauthenticated attacker to view data, change settings, impact availability of the software, or potentially impact a user�s local machine when the user clicks a specially crafted link. Affected Product: EcoStruxure Power Monitoring Expert (Versions 2020 and prior)
A CWE-20: Improper Input Validation vulnerability exists that could allow arbitrary files on the server to be read by authenticated users through a limited operating system service account. Affected Product: EcoStruxure Power Monitoring Expert (Versions 2020 and prior)
A CWE-20: Improper Input Validation vulnerability exists that could allow an authenticated attacker to gain the same privilege as the application on the server when a malicious payload is provided over HTTP for the server to execute.
A CWE-20: Improper Input Validation vulnerability exists in Custom Reports that could cause a macro to be executed, potentially leading to remote code execution when a user opens a malicious report file planted by an attacker. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior).
The Schneider Electric Telvent SAGE 3030 RTU with firmware C3413-500-001D3_P4 and C3413-500-001F0_PB allows remote attackers to cause a denial of service (temporary outage and CPU consumption) via malformed DNP3 traffic.
The client in Schneider Electric Software Update (SESU) Utility 1.0.x and 1.1.x does not ensure that updates have a valid origin, which allows man-in-the-middle attackers to spoof updates, and consequently execute arbitrary code, by modifying the data stream on TCP port 80.
A CWE-20: Improper input validation vulnerability exists in Easergy Builder (Version 1.4.7.2 and older) which could allow an attacker to modify project configuration files.
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow arbitrary system file download due to lack of validation of the shell meta characters with the value of 'system.download.sd_file'
An Improper Input Validation vulnerability exists in Pro-Face GP-Pro EX v4.08 and previous versions which could cause the execution arbitrary executable when GP-Pro EX is launched.
The vulnerability is due to insufficient handling of update_file request parameter on update_module.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. A remote, authenticated attacker can exploit this vulnerability by sending a crafted request to the target server.