Versions of the Official registry Docker images through 2.7.0 contain a blank password for the root user. Systems deployed using affected versions of the registry container may allow a remote attacker to achieve root access with a blank password.
In Solstice Pod before 3.3.0 (or Open4.3), the Administrator password can be enumerated using brute-force attacks via the /Config/service/initModel?password= Solstice Open Control API because there is no complexity requirement (e.g., it might be all digits or all lowercase letters).
An improper restriction of excessive authentication attempts [CWE-307] in FortiClientEMS version 7.2.0 through 7.2.4 and before 7.0.10 allows an unauthenticated attacker to try a brute force attack against the FortiClientEMS console via crafted HTTP or HTTPS requests.
A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause unauthorized command execution when a brute force attack is done over Modbus.
RAGFlow through 0.18.1 allows account takeover because it is possible to conduct successful brute-force attacks against email verification codes to perform arbitrary account registration, login, and password reset. Codes are six digits and there is no rate limiting.
An issue in GX Group GPON ONT Titanium 2122A T2122-V1.26EXL allows attackers to escalate privileges via a brute force attack at the login page.
IBM Security Guardium Big Data Intelligence (SonarG) 3.1 uses an inadequate account lockout setting that could allow a remote attacker to brute force account credentials. IBM X-Force ID: 137773.
Weak Password Requirements in GitHub repository thorsten/phpmyfaq prior to 3.1.8.
BookWyrm is a social network for tracking reading. Versions prior to 0.4.5 were found to lack rate limiting on authentication views which allows brute-force attacks. This issue has been patched in version 0.4.5. Admins with existing instances will need to update their `nginx.conf` file that was created when the instance was set up. Users are advised advised to upgrade. Users unable to upgrade may update their nginx.conf files with the changes manually.
An improper restriction of excessive authentication attempts vulnerability [CWE-307] in FortiTester Telnet port 2.3.0 through 3.9.1, 4.0.0 through 4.2.0, 7.0.0 through 7.1.0 may allow an unauthenticated attacker to guess the credentials of an admin user via a brute force attack.
Improper Restriction of Excessive Authentication Attempts in GitHub repository mastodon/mastodon prior to 4.0.0.
IBM Robotic Process Automation 21.0.0, 21.0.1, and 21.0.2 does not require that users should have strong passwords by default, which makes it easier for attackers to compromise user accounts. IBM X-Force ID: 230634.
A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow an attacker to manipulate the admin after numerous attempts at guessing credentials. Affected Product: spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior)
Renato v0.17.0 employs weak password complexity requirements, allowing attackers to crack user passwords via brute-force attacks.
Zammad 5.2.0 is vulnerable to privilege escalation. Zammad has a prevention against brute-force attacks trying to guess login credentials. After a configurable amount of attempts, users are invalidated and logins prevented. An attacker might work around this prevention, enabling them to send more than the configured amount of requests before the user invalidation takes place.
WiJungle NGFW Version U250 was discovered to be vulnerable to No Rate Limit attack, allowing the attacker to brute force the admin password leading to Account Take Over.
Weak Password Requirements in GitHub repository ikus060/minarca prior to 4.2.2.
A CWE-521: Weak Password Requirements vulnerability exists that could allow an attacker to gain control of the device when the attacker brute forces the password. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0)
An issue was discovered in app/Controller/UsersController.php in MISP 2.4.92. An adversary can bypass the brute-force protection by using a PUT HTTP method instead of a POST HTTP method in the login part, because this protection was only covering POST requests.
IBM Security Guardium Big Data Intelligence (SonarG) 3.1 does not require that users should have strong passwords by default, which makes it easier for attackers to compromise user accounts. IBM X-Force ID: 137772.
Dell EMC AppSync versions 3.9 to 4.3 contain an Improper Restriction of Excessive Authentication Attempts Vulnerability that can be exploited from UI and CLI. An adjacent unauthenticated attacker could potentially exploit this vulnerability, leading to password brute-forcing. Account takeover is possible if weak passwords are used by users.
The DIGITS: WordPress Mobile Number Signup and Login WordPress plugin before 8.4.6.1 does not rate limit OTP validation attempts, making it straightforward for attackers to bruteforce them.
An issue was discovered in SMA Solar Technology products. All inverters have a very weak password policy for the user and installer password. No complexity requirements or length requirements are set. Also, strong passwords are impossible due to a maximum of 12 characters and a limited set of characters. NOTE: the vendor reports that the 12-character limit provides "a very high security standard." Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected
Weak Password Requirements in GitHub repository kromitgmbh/titra prior to 0.78.1.
Dell EMC XtremIO versions prior to X2 6.4.0-22 contain a bruteforce vulnerability. A remote unauthenticated attacker can potentially exploit this vulnerability and gain access to an admin account.
Dell EMC PowerStore, contain(s) an Improper Restriction of Excessive Authentication Attempts Vulnerability in PowerStore Manager GUI. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to password brute-forcing. Account takeover is possible if weak passwords are used by users.
The National Payments Corporation of India BHIM application 1.3 for Android relies on a four-digit passcode, which makes it easier for attackers to obtain access.
An issue was discovered in Infiray IRAY-A8Z3 1.0.957. There is a blank root password for TELNET by default.
Agentflow from Flowring Technology has an Account Lockout Bypass vulnerability, allowing unauthenticated remote attackers to exploit this vulnerability to perform password brute force attack.
An issue in TopIDP3000 Topsec Operating System tos_3.3.005.665b.15_smpidp allows attackers to perform a brute-force attack via a crafted session_id cookie.
A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow unauthorized access when an attacker uses brute force. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
Verizon 4G LTE Network Extender GA4.38 - V0.4.038.2131 utilizes a weak default admin password generation algorithm which generates passwords that are accessible to unauthenticated attackers via the webUI login page.
Mealie 1.0.0beta3 employs weak password requirements which allows attackers to potentially gain unauthorized access to the application via brute-force attacks.
onefilecms.php in OneFileCMS through 2012-04-14 might allow attackers to conduct brute-force attacks via the onefilecms_username and onefilecms_password fields.
Dell PowerScale OneFS versions 8.2.0.x through 9.3.0.x, contain a weak password requirement vulnerability. An administrator may create an account with no password. A remote attacker may potentially exploit this leading to a user account compromise.
Dell Unity, Dell UnityVSA, and Dell Unity XT versions before 5.2.0.0.5.173 do not restrict excessive authentication attempts in Unisphere GUI. A remote unauthenticated attacker may potentially exploit this vulnerability to brute-force passwords and gain access to the system as the victim. Account takeover is possible if weak passwords are used by users.
In Sorcery before 0.15.0, there is a brute force vulnerability when using password authentication via Sorcery. The brute force protection submodule will prevent a brute force attack for the defined lockout period, but once expired, protection will not be re-enabled until a user or malicious actor logs in successfully. This does not affect users that do not use the built-in brute force protection submodule, nor users that use permanent account lockout. This has been patched in 0.15.0.
Weak Password Requirements in GitHub repository notrinos/notrinoserp prior to 0.7.
An issue was discovered on Marbella KR8s Dashcam FF 2.0.8 devices. Once access is gained either by default, common, or cracked passwords, the video recordings (containing sensitive routes, conversations, and footage) are open for downloading by creating a socket to command port 7777, and then downloading video via port 7778 and audio via port 7779.
A vulnerability has been identified in Mendix Forgot Password Appstore module (All versions >= V3.3.0 < V3.5.1), Mendix Forgot Password Appstore module (Mendix 7 compatible) (All versions < V3.2.2). Initial passwords are generated in an insecure manner. This could allow an unauthenticated remote attacker to efficiently brute force passwords in specific situations.
An issue was discovered on Samsung mobile devices with O(8.x) (with TEEGRIS) software. The Gatekeeper Trustlet allows a brute-force attack on user credentials. The Samsung ID is SVE-2020-16908 (June 2020).
The authentication implementation on the xArm controller has very low entropy, making it vulnerable to a brute-force attack. There is no mechanism in place to mitigate or lockout automated attempts to gain access.
Vasion Print (formerly PrinterLogic) before Virtual Appliance Host 22.0.843 Application 20.0.1923 allows Weak Password Encryption / Encoding OVE-20230524-0007.
Weak password requirements in OpenC3 COSMOS v6.0.0 allow attackers to bypass authentication via a brute force attack.
Victure RX1800 EN_V1.0.0_r12_110933 was discovered to utilize a weak default password which includes the last 8 digits of the Mac address.
Dell PowerScale OneFS, versions 8.2.x-9.3.0.x, contain an improper restriction of excessive authentication attempts. An unauthenticated remote attacker could potentially exploit this vulnerability, leading to compromised accounts.
User login brute force protection functionality bypass
Kapsch TrafficCom RIS-9160 & RIS-9260 Roadside Units (RSUs) v3.2.0.829.23, v3.8.0.1119.42, and v4.6.0.1211.28 were discovered to lack secure password requirements for its BIOS Supervisor and User accounts, allowing attackers to bypass authentication via a bruteforce attack.
A lack of rate limiting in the login page of Safe App version a3.0.9 allows attackers to bypass authentication via a brute force attack.
Askey AP5100W_Dual_SIG_1.01.097 and all prior versions use a weak password at the Operating System (rlx-linux) level. This allows an attacker to gain unauthorized access as an admin or root user to the device Operating System via Telnet or SSH.