A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:siemens
Assigner Org ID:cec7a2ec-15b4-4faf-bd53-b40f371f3a77
Published At:12 May, 2021 | 13:18
Updated At:03 Aug, 2024 | 20:48
Rejected At:
▼CVE Numbering Authority (CNA)

A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution.

Affected Products
Vendor
Siemens AGSiemens
Product
SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants)
Versions
Affected
  • All versions < V15.1 Update 6
Vendor
Siemens AGSiemens
Product
SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants)
Versions
Affected
  • All versions < V16 Update 4
Vendor
Siemens AGSiemens
Product
SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants)
Versions
Affected
  • All versions < V15.1 Update 6
Vendor
Siemens AGSiemens
Product
SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants)
Versions
Affected
  • All versions < V16 Update 4
Vendor
Siemens AGSiemens
Product
SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F
Versions
Affected
  • All versions < V15.1 Update 6
Vendor
Siemens AGSiemens
Product
SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F
Versions
Affected
  • All versions < V16 Update 4
Vendor
Siemens AGSiemens
Product
SIMATIC WinCC Runtime Advanced V15
Versions
Affected
  • All versions < V15.1 Update 6
Vendor
Siemens AGSiemens
Product
SIMATIC WinCC Runtime Advanced V16
Versions
Affected
  • All versions < V16 Update 4
Vendor
Siemens AGSiemens
Product
SINAMICS GH150
Versions
Affected
  • All versions
Vendor
Siemens AGSiemens
Product
SINAMICS GL150 (with option X30)
Versions
Affected
  • All versions
Vendor
Siemens AGSiemens
Product
SINAMICS GM150 (with option X30)
Versions
Affected
  • All versions
Vendor
Siemens AGSiemens
Product
SINAMICS SH150
Versions
Affected
  • All versions
Vendor
Siemens AGSiemens
Product
SINAMICS SL150
Versions
Affected
  • All versions
Vendor
Siemens AGSiemens
Product
SINAMICS SM120
Versions
Affected
  • All versions
Vendor
Siemens AGSiemens
Product
SINAMICS SM150
Versions
Affected
  • All versions
Vendor
Siemens AGSiemens
Product
SINAMICS SM150i
Versions
Affected
  • All versions
Problem Types
TypeCWE IDDescription
CWECWE-788CWE-788: Access of Memory Location After End of Buffer
Type: CWE
CWE ID: CWE-788
Description: CWE-788: Access of Memory Location After End of Buffer
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf
x_refsource_MISC
https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf
x_refsource_MISC
https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11
x_refsource_MISC
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf
Resource:
x_refsource_MISC
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf
Resource:
x_refsource_MISC
Hyperlink: https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11
Resource:
x_refsource_MISC
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf
x_refsource_MISC
x_transferred
https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf
x_refsource_MISC
x_transferred
https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11
x_refsource_MISC
x_transferred
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf
Resource:
x_refsource_MISC
x_transferred
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf
Resource:
x_refsource_MISC
x_transferred
Hyperlink: https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11
Resource:
x_refsource_MISC
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:productcert@siemens.com
Published At:12 May, 2021 | 14:15
Updated At:16 Dec, 2021 | 18:26

A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.19.8CRITICAL
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Primary2.07.5HIGH
AV:N/AC:L/Au:N/C:P/I:P/A:P
Type: Primary
Version: 3.1
Base score: 9.8
Base severity: CRITICAL
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 2.0
Base score: 7.5
Base severity: HIGH
Vector:
AV:N/AC:L/Au:N/C:P/I:P/A:P
CPE Matches

Siemens AG
siemens
>>simatic_wincc_runtime_advanced>>Versions before 16(exclusive)
cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>simatic_wincc_runtime_advanced>>16
cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:-:*:*:*:*:*:*
Siemens AG
siemens
>>simatic_wincc_runtime_advanced>>16
cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update1:*:*:*:*:*:*
Siemens AG
siemens
>>simatic_wincc_runtime_advanced>>16
cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update2:*:*:*:*:*:*
Siemens AG
siemens
>>simatic_wincc_runtime_advanced>>16
cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update3:*:*:*:*:*:*
Siemens AG
siemens
>>sinamics_sh150_firmware>>*
cpe:2.3:o:siemens:sinamics_sh150_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>sinamics_sh150>>-
cpe:2.3:h:siemens:sinamics_sh150:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>sinamics_sm150i_firmware>>*
cpe:2.3:o:siemens:sinamics_sm150i_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>sinamics_sm150i>>-
cpe:2.3:h:siemens:sinamics_sm150i:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>sinamics_gh150_firmware>>*
cpe:2.3:o:siemens:sinamics_gh150_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>sinamics_gh150>>-
cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>sinamics_gl150_firmware>>*
cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>sinamics_gl150>>-
cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>sinamics_gm150_firmware>>*
cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>sinamics_gm150>>-
cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>sinamics_sl150_firmware>>*
cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>sinamics_sl150>>-
cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>sinamics_sm120_firmware>>*
cpe:2.3:o:siemens:sinamics_sm120_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>sinamics_sm120>>-
cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>sinamics_sm150_firmware>>*
cpe:2.3:o:siemens:sinamics_sm150_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>sinamics_sm150>>-
cpe:2.3:h:siemens:sinamics_sm150:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>simatic_hmi_comfort_outdoor_panels_7\"_firmware>>Versions before 16(exclusive)
cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\"_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>simatic_hmi_comfort_outdoor_panels_7\"_firmware>>16
cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\"_firmware:16:-:*:*:*:*:*:*
Siemens AG
siemens
>>simatic_hmi_comfort_outdoor_panels_7\"_firmware>>16
cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\"_firmware:16:update1:*:*:*:*:*:*
Siemens AG
siemens
>>simatic_hmi_comfort_outdoor_panels_7\"_firmware>>16
cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\"_firmware:16:update2:*:*:*:*:*:*
Siemens AG
siemens
>>simatic_hmi_comfort_outdoor_panels_7\"_firmware>>16
cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\"_firmware:16:update3:*:*:*:*:*:*
Siemens AG
siemens
>>simatic_hmi_comfort_outdoor_panels_7\">>-
cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\":-:*:*:*:*:*:*:*
Siemens AG
siemens
>>simatic_hmi_comfort_outdoor_panels_15\"_firmware>>Versions before 16(exclusive)
cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\"_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>simatic_hmi_comfort_outdoor_panels_15\"_firmware>>16
cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\"_firmware:16:*:*:*:*:*:*:*
Siemens AG
siemens
>>simatic_hmi_comfort_outdoor_panels_15\"_firmware>>16
cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\"_firmware:16:-:*:*:*:*:*:*
Siemens AG
siemens
>>simatic_hmi_comfort_outdoor_panels_15\"_firmware>>16
cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\"_firmware:16:update1:*:*:*:*:*:*
Siemens AG
siemens
>>simatic_hmi_comfort_outdoor_panels_15\"_firmware>>16
cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\"_firmware:16:update2:*:*:*:*:*:*
Siemens AG
siemens
>>simatic_hmi_comfort_outdoor_panels_15\"_firmware>>16
cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\"_firmware:16:update3:*:*:*:*:*:*
Siemens AG
siemens
>>simatic_hmi_comfort_outdoor_panels_15\">>-
cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\":-:*:*:*:*:*:*:*
Siemens AG
siemens
>>simatic_hmi_comfort_panels_4\"_firmware>>Versions before 16(exclusive)
cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\"_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>simatic_hmi_comfort_panels_4\"_firmware>>16
cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\"_firmware:16:-:*:*:*:*:*:*
Siemens AG
siemens
>>simatic_hmi_comfort_panels_4\"_firmware>>16
cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\"_firmware:16:update1:*:*:*:*:*:*
Siemens AG
siemens
>>simatic_hmi_comfort_panels_4\"_firmware>>16
cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\"_firmware:16:update2:*:*:*:*:*:*
Siemens AG
siemens
>>simatic_hmi_comfort_panels_4\"_firmware>>16
cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\"_firmware:16:update3:*:*:*:*:*:*
Siemens AG
siemens
>>simatic_hmi_comfort_panels_4\">>-
cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\":-:*:*:*:*:*:*:*
Siemens AG
siemens
>>simatic_hmi_comfort_panels_22\"_firmware>>Versions before 16(exclusive)
cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\"_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>simatic_hmi_comfort_panels_22\"_firmware>>16
cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\"_firmware:16:-:*:*:*:*:*:*
Siemens AG
siemens
>>simatic_hmi_comfort_panels_22\"_firmware>>16
cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\"_firmware:16:update1:*:*:*:*:*:*
Siemens AG
siemens
>>simatic_hmi_comfort_panels_22\"_firmware>>16
cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\"_firmware:16:update2:*:*:*:*:*:*
Siemens AG
siemens
>>simatic_hmi_comfort_panels_22\"_firmware>>16
cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\"_firmware:16:update3:*:*:*:*:*:*
Siemens AG
siemens
>>simatic_hmi_comfort_panels_22\">>-
cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\":-:*:*:*:*:*:*:*
Siemens AG
siemens
>>simatic_hmi_ktp_mobile_panels_ktp400f_firmware>>Versions before 16(exclusive)
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>simatic_hmi_ktp_mobile_panels_ktp400f_firmware>>16
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:-:*:*:*:*:*:*
Siemens AG
siemens
>>simatic_hmi_ktp_mobile_panels_ktp400f_firmware>>16
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update1:*:*:*:*:*:*
Siemens AG
siemens
>>simatic_hmi_ktp_mobile_panels_ktp400f_firmware>>16
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update2:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-788Primaryproductcert@siemens.com
CWE ID: CWE-788
Type: Primary
Source: productcert@siemens.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdfproductcert@siemens.com
Patch
Vendor Advisory
https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdfproductcert@siemens.com
Patch
Vendor Advisory
https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11productcert@siemens.com
Third Party Advisory
US Government Resource
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf
Source: productcert@siemens.com
Resource:
Patch
Vendor Advisory
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf
Source: productcert@siemens.com
Resource:
Patch
Vendor Advisory
Hyperlink: https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11
Source: productcert@siemens.com
Resource:
Third Party Advisory
US Government Resource

Change History

0
Information is not available yet

Similar CVEs

209Records found

CVE-2025-27540
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.3||CRITICAL
EPSS-0.18% / 39.78%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:37
Updated-19 Aug, 2025 | 14:49
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'Authenticate' method. This could allow an unauthenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25913)

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2019-6580
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-0.38% / 58.61%
||
7 Day CHG~0.00%
Published-12 Jun, 2019 | 13:47
Updated-04 Aug, 2024 | 20:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Siveillance VMS 2017 R2 (All versions < V11.2a), Siveillance VMS 2018 R1 (All versions < V12.1a), Siveillance VMS 2018 R2 (All versions < V12.2a), Siveillance VMS 2018 R3 (All versions < V12.3a), Siveillance VMS 2019 R1 (All versions < V13.1a). An attacker with network access to port 80/TCP could change device properties without authorization. No user interaction is required to exploit this security vulnerability. Successful exploitation compromises confidentiality, integrity and availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-siveillance_video_management_software_2017_r2siveillance_video_management_software_2019_r1siveillance_video_management_software_2018_r2siveillance_video_management_software_2018_r1siveillance_video_management_software_2018_r3Siveillance VMS 2018 R3Siveillance VMS 2018 R1Siveillance VMS 2019 R1Siveillance VMS 2017 R2Siveillance VMS 2018 R2
CWE ID-CWE-862
Missing Authorization
CVE-2019-5319
Matching Score-8
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-8
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-9.8||CRITICAL
EPSS-1.74% / 81.72%
||
7 Day CHG~0.00%
Published-30 Mar, 2021 | 01:45
Updated-04 Aug, 2024 | 19:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A remote buffer overflow vulnerability was discovered in some Aruba Instant Access Point (IAP) products in version(s): Aruba Instant 6.4.x: 6.4.4.8-4.2.4.17 and below; Aruba Instant 6.5.x: 6.5.4.16 and below; Aruba Instant 8.3.x: 8.3.0.12 and below; Aruba Instant 8.5.x: 8.5.0.6 and below; Aruba Instant 8.6.x: 8.6.0.2 and below. Aruba has released patches for Aruba Instant that address this security vulnerability.

Action-Not Available
Vendor-n/aSiemens AGAruba Networks
Product-scalance_w1750d_firmwareinstantscalance_w1750dAruba Instant Access Points
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2019-6579
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-2.03% / 83.05%
||
7 Day CHG~0.00%
Published-17 Apr, 2019 | 13:40
Updated-04 Aug, 2024 | 20:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Spectrum Power 4 (with Web Office Portal). An attacker with network access to the web server on port 80/TCP or 443/TCP could execute system commands with administrative privileges. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises confidentiality, integrity or availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-spectrum_power_4Spectrum Power™ 4
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-27539
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.3||CRITICAL
EPSS-0.18% / 39.78%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:37
Updated-19 Aug, 2025 | 14:49
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'VerifyUser' method. This could allow an unauthenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25914)

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2022-36361
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-0.47% / 63.71%
||
7 Day CHG~0.00%
Published-11 Oct, 2022 | 00:00
Updated-20 Nov, 2024 | 14:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions). Affected devices do not properly validate the structure of TCP packets in several methods. This could allow an attacker to cause buffer overflows, get control over the instruction counter and run custom code.

Action-Not Available
Vendor-Siemens AG
Product-logo\!8_bm_fs-05logo\!8_bm_fs-05_firmwarelogo\!8_bmlogo\!_8_bm_firmwareLOGO! 230RCEoSIPLUS LOGO! 24CEoLOGO! 12/24RCELOGO! 24RCEoSIPLUS LOGO! 12/24RCEoLOGO! 24CEoSIPLUS LOGO! 24RCEoLOGO! 24RCESIPLUS LOGO! 24CELOGO! 12/24RCEoLOGO! 230RCESIPLUS LOGO! 230RCEoLOGO! 24CESIPLUS LOGO! 24RCESIPLUS LOGO! 12/24RCESIPLUS LOGO! 230RCE
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2019-18314
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-2.86% / 85.73%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-05 Aug, 2024 | 01:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could gain remote code execution by sending specifically crafted objects via RMI. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sppa-t3000_application_serverSPPA-T3000 Application Server
CWE ID-CWE-287
Improper Authentication
CVE-2025-26390
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.3||CRITICAL
EPSS-0.10% / 27.75%
||
7 Day CHG~0.00%
Published-13 May, 2025 | 09:38
Updated-13 May, 2025 | 19:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in OZW672 (All versions < V6.0), OZW772 (All versions < V6.0). The web service of affected devices is vulnerable to SQL injection when checking authentication data. This could allow an unauthenticated remote attacker to bypass the check and authenticate as Administrator user.

Action-Not Available
Vendor-Siemens AG
Product-OZW772OZW672
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2019-3822
Matching Score-8
Assigner-Red Hat, Inc.
ShareView Details
Matching Score-8
Assigner-Red Hat, Inc.
CVSS Score-7.1||HIGH
EPSS-30.92% / 96.58%
||
7 Day CHG~0.00%
Published-06 Feb, 2019 | 20:00
Updated-04 Aug, 2024 | 19:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

libcurl versions from 7.36.0 to before 7.64.0 are vulnerable to a stack-based buffer overflow. The function creating an outgoing NTLM type-3 header (`lib/vauth/ntlm.c:Curl_auth_create_ntlm_type3_message()`), generates the request HTTP header contents based on previously received data. The check that exists to prevent the local buffer from getting overflowed is implemented wrongly (using unsigned math) and as such it does not prevent the overflow from happening. This output data can grow larger than the local buffer if very large 'nt response' data is extracted from a previous NTLMv2 header provided by the malicious or broken HTTP server. Such a 'large value' needs to be around 1000 bytes or more. The actual payload data copied to the target buffer comes from the NTLMv2 type-2 response header.

Action-Not Available
Vendor-NetApp, Inc.Debian GNU/LinuxOracle CorporationRed Hat, Inc.Canonical Ltd.Siemens AGCURL
Product-libcurlubuntu_linuxcommunications_operations_monitoroncommand_insightenterprise_linuxactive_iq_unified_managerservices_tools_bundleoncommand_workflow_automationsnapcenterhttp_serverclustered_data_ontapdebian_linuxsecure_global_desktopsinema_remote_connect_cliententerprise_manager_ops_centermysql_servercurl
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2019-18342
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.9||CRITICAL
EPSS-0.57% / 67.55%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-05 Aug, 2024 | 01:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The SFTP service (default port 22/tcp) of the Control Center Server (CCS) does not properly limit its capabilities to the specified purpose. In conjunction with CVE-2019-18341, an unauthenticated remote attacker with network access to the CCS server could exploit this vulnerability to read or delete arbitrary files, or access other resources on the same server.

Action-Not Available
Vendor-Siemens AG
Product-control_center_serverControl Center Server (CCS)
CWE ID-CWE-749
Exposed Dangerous Method or Function
CVE-2023-37372
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-0.68% / 70.72%
||
7 Day CHG~0.00%
Published-08 Aug, 2023 | 09:20
Updated-27 Feb, 2025 | 21:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.4). The affected applications is vulnerable to SQL injection. This could allow an unauthenticated remote attackers to execute arbitrary SQL queries on the server database.

Action-Not Available
Vendor-Siemens AG
Product-ruggedcom_crossbowRUGGEDCOM CROSSBOW
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2019-20788
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.84% / 73.86%
||
7 Day CHG~0.00%
Published-23 Apr, 2020 | 18:06
Updated-05 Aug, 2024 | 02:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

libvncclient/cursor.c in LibVNCServer through 0.9.12 has a HandleCursorShape integer overflow and heap-based buffer overflow via a large height or width value. NOTE: this may overlap CVE-2019-15690.

Action-Not Available
Vendor-libvnc_projectn/aDebian GNU/LinuxSiemens AGCanonical Ltd.
Product-simatic_itc1500_pro_firmwareubuntu_linuxdebian_linuxsimatic_itc1500_prosimatic_itc1500simatic_itc1900simatic_itc1900_firmwaresimatic_itc1900_pro_firmwaresimatic_itc1500_firmwaresimatic_itc2200_firmwaresimatic_itc2200_prosimatic_itc2200_pro_firmwarelibvncserversimatic_itc1900_prosimatic_itc2200n/a
CWE ID-CWE-787
Out-of-bounds Write
CWE ID-CWE-190
Integer Overflow or Wraparound
CVE-2023-36380
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-0.06% / 19.75%
||
7 Day CHG~0.00%
Published-10 Oct, 2023 | 10:21
Updated-27 Feb, 2025 | 20:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05.11 (only with activated debug support)), CP-8050 MASTER MODULE (All versions < CPCI85 V05.11 (only with activated debug support)). The affected devices contain a hard-coded ID in the SSH `authorized_keys` configuration file. An attacker with knowledge of the corresponding private key could login to the device via SSH. Only devices with activated debug support are affected.

Action-Not Available
Vendor-Siemens AG
Product-cp-8050_firmwarecp-8050cp-8031_firmwarecp-8031CP-8031 MASTER MODULECP-8050 MASTER MODULE
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2019-19317
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-3.56% / 87.24%
||
7 Day CHG~0.00%
Published-05 Dec, 2019 | 13:53
Updated-05 Aug, 2024 | 02:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

lookupName in resolve.c in SQLite 3.30.1 omits bits from the colUsed bitmask in the case of a generated column, which allows attackers to cause a denial of service or possibly have unspecified other impact.

Action-Not Available
Vendor-sqliten/aNetApp, Inc.Oracle CorporationSiemens AG
Product-sinec_infrastructure_network_servicescloud_backupsqliteontap_select_deploy_administration_utilitymysql_workbenchn/a
CWE ID-CWE-681
Incorrect Conversion between Numeric Types
CVE-2019-19646
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-21.53% / 95.50%
||
7 Day CHG~0.00%
Published-09 Dec, 2019 | 18:36
Updated-05 Aug, 2024 | 02:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

pragma.c in SQLite through 3.30.1 mishandles NOT NULL in an integrity_check PRAGMA command in certain cases of generated columns.

Action-Not Available
Vendor-sqliten/aNetApp, Inc.Oracle CorporationTenable, Inc.Siemens AG
Product-sinec_infrastructure_network_servicescloud_backupsqliteontap_select_deploy_administration_utilitytenable.scmysql_workbenchn/a
CWE ID-CWE-754
Improper Check for Unusual or Exceptional Conditions
CVE-2019-18296
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-2.55% / 84.91%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-05 Aug, 2024 | 01:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server could trigger a Denial-of-Service condition and potentially gain remote code execution by sending specifically crafted packets to port 5010/tcp. This vulnerability is independent from CVE-2019-18289, CVE-2019-18293, and CVE-2019-18295. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sppa-t3000_ms3000_migration_serverSPPA-T3000 MS3000 Migration Server
CWE ID-CWE-122
Heap-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2019-18328
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-1.43% / 79.83%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-05 Aug, 2024 | 01:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server can cause a Denial-of-Service condition and potentially gain remote code execution by sending specifically crafted packets to 5010/tcp. This vulnerability is independent from CVE-2019-18323, CVE-2019-18324, CVE-2019-18325, CVE-2019-18326, CVE-2019-18327, CVE-2019-18329, and CVE-2019-18330. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sppa-t3000_ms3000_migration_serverSPPA-T3000 MS3000 Migration Server
CWE ID-CWE-122
Heap-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2019-18315
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-1.02% / 76.33%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-05 Aug, 2024 | 01:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could gain remote code execution by sending specifically crafted packets to 8888/tcp. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sppa-t3000_application_serverSPPA-T3000 Application Server
CWE ID-CWE-287
Improper Authentication
CVE-2019-18337
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-0.07% / 22.98%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-15 Oct, 2024 | 18:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The Control Center Server (CCS) contains an authentication bypass vulnerability in its XML-based communication protocol as provided by default on ports 5444/tcp and 5440/tcp. A remote attacker with network access to the CCS server could exploit this vulnerability to read the CCS users database, including the passwords of all users in obfuscated cleartext.

Action-Not Available
Vendor-Siemens AG
Product-sinvr_3_video_serversinvr_3_central_control_serverControl Center Server (CCS)
CWE ID-CWE-287
Improper Authentication
CVE-2022-29875
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-2.37% / 84.34%
||
7 Day CHG~0.00%
Published-01 Jun, 2022 | 09:50
Updated-03 Aug, 2024 | 06:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Biograph Horizon PET/CT Systems (All VJ30 versions < VJ30C-UD01), MAGNETOM Family (NUMARIS X: VA12M, VA12S, VA10B, VA20A, VA30A, VA31A), MAMMOMAT Revelation (All VC20 versions < VC20D), NAEOTOM Alpha (All VA40 versions < VA40 SP2), SOMATOM X.cite (All versions < VA30 SP5 or VA40 SP2), SOMATOM X.creed (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.All (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.Now (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.Open Pro (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.Sim (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.Top (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.Up (All versions < VA30 SP5 or VA40 SP2), Symbia E/S (All VB22 versions < VB22A-UD03), Symbia Evo (All VB22 versions < VB22A-UD03), Symbia Intevo (All VB22 versions < VB22A-UD03), Symbia T (All VB22 versions < VB22A-UD03), Symbia.net (All VB22 versions < VB22A-UD03), syngo.via VB10 (All versions), syngo.via VB20 (All versions), syngo.via VB30 (All versions), syngo.via VB40 (All versions < VB40B HF06), syngo.via VB50 (All versions), syngo.via VB60 (All versions < VB60B HF02). The application deserialises untrusted data without sufficient validations that could result in an arbitrary deserialization. This could allow an unauthenticated attacker to execute code in the affected system if ports 32912/tcp or 32914/tcp are reachable.

Action-Not Available
Vendor-Siemens AG
Product-somatom_x.citesomatom_go.nowsymbia_intevosymbia_e_firmwaresymbia_evo_firmwaresomatom_go.allmammomat_revelation_firmwaresomatom_x.cite_firmwaresomatom_x.creedsymbia_tsyngo.viasymbia_s_firmwaresomatom_go.upsymbia_ssomatom_go.open_pro_firmwaresomatom_go.simsomatom_go.all_firmwaremagnetom_numaris_xmammomat_revelationsymbia_t_firmwaresomatom_go.up_firmwaresomatom_x.creed_firmwaresomatom_go.sim_firmwaresomatom_go.now_firmwaresymbia_intevo_firmwaresymbia_evonaeotom_alphabiograph_horizon_pet\/ct_systems_firmwaresymbia_enaeotom_alpha_firmwaresomatom_go.open_promagnetom_numaris_x_firmwarebiograph_horizon_pet\/ct_systemssymbia.netSymbia Intevosyngo.via VB30SOMATOM go.UpBiograph Horizon PET/CT SystemsMAMMOMAT RevelationSymbia.netSOMATOM go.AllMAGNETOM FamilySOMATOM X.creedsyngo.via VB40Symbia E/SSOMATOM go.SimSOMATOM go.Topsyngo.via VB50Symbia EvoSOMATOM go.NowSOMATOM X.citeSOMATOM go.Open Prosyngo.via VB20syngo.via VB10NAEOTOM Alphasyngo.via VB60Symbia T
CWE ID-CWE-502
Deserialization of Untrusted Data
CVE-2019-18284
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-0.39% / 59.23%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-05 Aug, 2024 | 01:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). The AdminService is available without authentication on the Application Server. An attacker can use methods exposed via this interface to receive password hashes of other users and to change user passwords. Please note that an attacker needs to have access to the Application Highway in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sppa-t3000_application_serverSPPA-T3000 Application Server
CWE ID-CWE-287
Improper Authentication
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-18323
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-1.43% / 79.83%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-05 Aug, 2024 | 01:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server could cause a Denial-of-Service condition and potentially gain remote code execution by sending specifically crafted packets to 5010/tcp. This vulnerability is independent from CVE-2019-18324, CVE-2019-18325, CVE-2019-18326, CVE-2019-18327, CVE-2019-18328, CVE-2019-18329, and CVE-2019-18330. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sppa-t3000_ms3000_migration_serverSPPA-T3000 MS3000 Migration Server
CWE ID-CWE-122
Heap-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2019-18289
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-2.55% / 84.91%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-05 Aug, 2024 | 01:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server could trigger a Denial-of-Service condition and potentially gain remote code execution by sending specifically crafted packets to port 5010/tcp. This vulnerability is independent from CVE-2019-18293, CVE-2019-18295, and CVE-2019-18296. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sppa-t3000_ms3000_migration_serverSPPA-T3000 MS3000 Migration Server
CWE ID-CWE-122
Heap-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2019-18329
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-1.43% / 79.83%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-05 Aug, 2024 | 01:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server can cause a Denial-of-Service condition and potentially gain remote code execution by sending specifically crafted packets to 5010/tcp. This vulnerability is independent from CVE-2019-18323, CVE-2019-18324, CVE-2019-18325, CVE-2019-18326, CVE-2019-18327, CVE-2019-18328, and CVE-2019-18330. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sppa-t3000_ms3000_migration_serverSPPA-T3000 MS3000 Migration Server
CWE ID-CWE-122
Heap-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2019-18316
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-1.71% / 81.61%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-05 Aug, 2024 | 01:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could gain remote code execution by sending specifically crafted packets to 1099/tcp. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sppa-t3000_application_serverSPPA-T3000 Application Server
CWE ID-CWE-502
Deserialization of Untrusted Data
CVE-2019-18324
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-1.43% / 79.83%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-05 Aug, 2024 | 01:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server can cause a Denial-of-Service condition and potentially gain remote code execution by sending specifically crafted packets to 5010/tcp. This vulnerability is independent from CVE-2019-18323, CVE-2019-18325, CVE-2019-18326, CVE-2019-18327, CVE-2019-18328, CVE-2019-18329, and CVE-2019-18330. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sppa-t3000_ms3000_migration_serverSPPA-T3000 MS3000 Migration Server
CWE ID-CWE-122
Heap-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2019-18283
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-11.46% / 93.33%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-05 Aug, 2024 | 01:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). The AdminService is available without authentication on the Application Server. An attacker can gain remote code execution by sending specifically crafted objects to one of its functions. Please note that an attacker needs to have access to the Application Highway in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sppa-t3000_application_serverSPPA-T3000 Application Server
CWE ID-CWE-502
Deserialization of Untrusted Data
CVE-2019-18327
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-1.43% / 79.83%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-05 Aug, 2024 | 01:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server can cause a Denial-of-Service condition and potentially gain remote code execution by sending specifically crafted packets to 5010/tcp. This vulnerability is independent from CVE-2019-18323, CVE-2019-18324, CVE-2019-18325, CVE-2019-18326, CVE-2019-18328, CVE-2019-18329, and CVE-2019-18330. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sppa-t3000_ms3000_migration_serverSPPA-T3000 MS3000 Migration Server
CWE ID-CWE-122
Heap-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2019-17006
Matching Score-8
Assigner-Mozilla Corporation
ShareView Details
Matching Score-8
Assigner-Mozilla Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.45% / 62.90%
||
7 Day CHG~0.00%
Published-22 Oct, 2020 | 20:24
Updated-05 Aug, 2024 | 01:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Network Security Services (NSS) before 3.46, several cryptographic primitives had missing length checks. In cases where the application calling the library did not perform a sanity check on the inputs it could result in a crash due to a buffer overflow.

Action-Not Available
Vendor-Mozilla CorporationNetApp, Inc.Siemens AG
Product-ruggedcom_rox_rx1511ruggedcom_rox_rx1512hci_storage_nodenetwork_security_servicesruggedcom_rox_mx5000_firmwareruggedcom_rox_rx5000_firmwareruggedcom_rox_rx1511_firmwareruggedcom_rox_rx1510hci_compute_noderuggedcom_rox_rx1400_firmwaresolidfireruggedcom_rox_rx1400ruggedcom_rox_rx1510_firmwareruggedcom_rox_rx1500ruggedcom_rox_rx5000ruggedcom_rox_rx1501hci_management_noderuggedcom_rox_mx5000ruggedcom_rox_rx1500_firmwareruggedcom_rox_rx1501_firmwareruggedcom_rox_rx1512_firmwareNSS
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-20
Improper Input Validation
CVE-2023-28489
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-1.60% / 80.93%
||
7 Day CHG~0.00%
Published-11 Apr, 2023 | 09:03
Updated-13 Feb, 2025 | 16:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05), CP-8050 MASTER MODULE (All versions < CPCI85 V05). Affected devices are vulnerable to command injection via the web server port 443/tcp, if the parameter “Remote Operation” is enabled. The parameter is disabled by default. The vulnerability could allow an unauthenticated remote attacker to perform arbitrary code execution on the device.

Action-Not Available
Vendor-Siemens AG
Product-cp-8050_firmwarecp-8031cp-8031_firmwarecp-8050CP-8031 MASTER MODULECP-8050 MASTER MODULE
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2019-18326
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-1.43% / 79.83%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-05 Aug, 2024 | 01:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server can cause a Denial-of-Service condition and potentially gain remote code execution by sending specifically crafted packets to 5010/tcp. This vulnerability is independent from CVE-2019-18323, CVE-2019-18324, CVE-2019-18325, CVE-2019-18327, CVE-2019-18328, CVE-2019-18329, and CVE-2019-18330. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sppa-t3000_ms3000_migration_serverSPPA-T3000 MS3000 Migration Server
CWE ID-CWE-122
Heap-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2019-18330
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-1.43% / 79.83%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-05 Aug, 2024 | 01:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server could cause a Denial-of-Service condition and potentially gain remote code execution by sending specifically crafted packets to 5010/tcp. This vulnerability is independent from CVE-2019-18323, CVE-2019-18324, CVE-2019-18325, CVE-2019-18326, CVE-2019-18327, CVE-2019-18328, and CVE-2019-18329. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sppa-t3000_ms3000_migration_serverSPPA-T3000 MS3000 Migration Server
CWE ID-CWE-122
Heap-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2019-18295
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-2.55% / 84.91%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-05 Aug, 2024 | 01:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server could trigger a Denial-of-Service condition and potentially gain remote code execution by sending specifically crafted packets to port 5010/tcp. This vulnerability is independent from CVE-2019-18289, CVE-2019-18293, and CVE-2019-18296. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sppa-t3000_ms3000_migration_serverSPPA-T3000 MS3000 Migration Server
CWE ID-CWE-122
Heap-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2019-18313
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-3.95% / 87.88%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-05 Aug, 2024 | 01:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server could gain remote code execution by sending specifically crafted objects to one of the RPC services. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sppa-t3000_ms3000_migration_serverSPPA-T3000 MS3000 Migration Server
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CVE-2019-18325
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-1.43% / 79.83%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-05 Aug, 2024 | 01:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server can cause a Denial-of-Service condition and potentially gain remote code execution by sending specifically crafted packets to 5010/tcp. This vulnerability is independent from CVE-2019-18323, CVE-2019-18324, CVE-2019-18326, CVE-2019-18327, CVE-2019-18328, CVE-2019-18329, and CVE-2019-18330. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sppa-t3000_ms3000_migration_serverSPPA-T3000 MS3000 Migration Server
CWE ID-CWE-122
Heap-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-46353
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-1.40% / 79.62%
||
7 Day CHG~0.00%
Published-13 Dec, 2022 | 00:00
Updated-22 Apr, 2025 | 03:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SCALANCE X204RNA (HSR) (All versions < V3.2.7), SCALANCE X204RNA (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (HSR) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP/HSR) (All versions < V3.2.7). The webserver of affected devices calculates session ids and nonces in an insecure manner. This could allow an unauthenticated remote attacker to brute-force session ids and hijack existing sessions.

Action-Not Available
Vendor-Siemens AG
Product-6gk5204-0bs00-3pa36gk5204-0ba00-2mb2_firmware6gk5204-0ba00-2kb2_firmware6gk5204-0ba00-2mb26gk5204-0ba00-2kb26gk5204-0bs00-3la3_firmware6gk5204-0bs00-2na3_firmware6gk5204-0bs00-3pa3_firmware6gk5204-0bs00-2na36gk5204-0bs00-3la3SCALANCE X204RNA (HSR)SCALANCE X204RNA EEC (PRP/HSR)SCALANCE X204RNA EEC (PRP)SCALANCE X204RNA EEC (HSR)SCALANCE X204RNA (PRP)
CWE ID-CWE-330
Use of Insufficiently Random Values
CVE-2019-12261
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-17.18% / 94.76%
||
7 Day CHG~0.00%
Published-09 Aug, 2019 | 20:27
Updated-04 Aug, 2024 | 23:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Wind River VxWorks 6.7 though 6.9 and vx7 has a Buffer Overflow in the TCP component (issue 3 of 4). This is an IPNET security vulnerability: TCP Urgent Pointer state confusion during connect() to a remote host.

Action-Not Available
Vendor-windriverbeldenn/aNetApp, Inc.Oracle CorporationSonicWall Inc.Siemens AG
Product-power_meter_9810_firmwarehirschmann_rsp20ruggedcom_win7025_firmwarehirschmann_ees25sonicoshirschmann_grs1030hirschmann_grs1142ruggedcom_win7018_firmwarehirschmann_rspe32hirschmann_grs1130garrettcom_magnum_dx940ehirschmann_rspe35hirschmann_eesx20hirschmann_rspe37ruggedcom_win7018power_meter_9410_firmwarehirschmann_grs1042siprotec_5_firmwareruggedcom_win7000ruggedcom_win7200hirschmann_rsp35garrettcom_magnum_dx940e_firmwaree-series_santricity_os_controllervxworkshirschmann_msp40hirschmann_octopus_os3hirschmann_rsp30communications_eaglehirschmann_dragon_mach4000hirschmann_dragon_mach4500hirschmann_msp32hirschmann_rsp25hirschmann_rail_switch_power_smarthirschmann_eesx30hirschmann_grs1020hirschmann_rail_switch_power_litehirschmann_eagle20hirschmann_eagle30hirschmann_hiosruggedcom_win7025hirschmann_rspe30hirschmann_eagle_oneruggedcom_win7200_firmwaresiprotec_5hirschmann_ees20hirschmann_red25power_meter_9410power_meter_9810ruggedcom_win7000_firmwarehirschmann_msp30hirschmann_grs1120n/a
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2019-12256
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-17.71% / 94.85%
||
7 Day CHG~0.00%
Published-09 Aug, 2019 | 17:57
Updated-04 Aug, 2024 | 23:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Wind River VxWorks 6.9 and vx7 has a Buffer Overflow in the IPv4 component. There is an IPNET security vulnerability: Stack overflow in the parsing of IPv4 packets’ IP options.

Action-Not Available
Vendor-windriverbeldenn/aNetApp, Inc.Siemens AGSonicWall Inc.
Product-power_meter_9810_firmwarehirschmann_rsp20ruggedcom_win7025_firmwarehirschmann_ees25sonicoshirschmann_grs1030hirschmann_grs1142ruggedcom_win7018_firmwarehirschmann_rspe32hirschmann_grs1130garrettcom_magnum_dx940ehirschmann_rspe35hirschmann_eesx20hirschmann_rspe37ruggedcom_win7018power_meter_9410_firmwarehirschmann_grs1042siprotec_5_firmwareruggedcom_win7000ruggedcom_win7200hirschmann_rsp35garrettcom_magnum_dx940e_firmwaree-series_santricity_os_controllervxworkshirschmann_msp40hirschmann_octopus_os3hirschmann_rsp30hirschmann_dragon_mach4000hirschmann_dragon_mach4500hirschmann_msp32hirschmann_rsp25hirschmann_rail_switch_power_smarthirschmann_eesx30hirschmann_grs1020hirschmann_rail_switch_power_litehirschmann_eagle20hirschmann_eagle30hirschmann_hiosruggedcom_win7025hirschmann_rspe30hirschmann_eagle_oneruggedcom_win7200_firmwaresiprotec_5hirschmann_ees20hirschmann_red25power_meter_9410power_meter_9810ruggedcom_win7000_firmwarehirschmann_msp30hirschmann_grs1120n/a
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2019-12815
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-81.81% / 99.15%
||
7 Day CHG~0.00%
Published-19 Jul, 2019 | 22:56
Updated-04 Aug, 2024 | 23:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An arbitrary file copy vulnerability in mod_copy in ProFTPD up to 1.3.5b allows for remote code execution and information disclosure without authentication, a related issue to CVE-2015-3306.

Action-Not Available
Vendor-proftpdn/aDebian GNU/LinuxSiemens AGFedora Project
Product-debian_linuxsimatic_cp_1543-1_firmwarefedoraproftpdsimatic_cp_1543-1n/a
CWE ID-CWE-755
Improper Handling of Exceptional Conditions
CVE-2019-12262
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.42% / 61.19%
||
7 Day CHG~0.00%
Published-14 Aug, 2019 | 19:18
Updated-04 Aug, 2024 | 23:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Wind River VxWorks 6.6, 6.7, 6.8, 6.9 and 7 has Incorrect Access Control in the RARP client component. IPNET security vulnerability: Handling of unsolicited Reverse ARP replies (Logical Flaw).

Action-Not Available
Vendor-windriverbeldenn/aSiemens AG
Product-hirschmann_rsp20ruggedcom_win7025_firmwarehirschmann_ees25hirschmann_grs1142hirschmann_grs1030ruggedcom_win7018_firmwarehirschmann_rspe32hirschmann_grs1130garrettcom_magnum_dx940ehirschmann_rspe35hirschmann_eesx20hirschmann_rspe37ruggedcom_win7018hirschmann_grs1042hirschmann_rsp35ruggedcom_win7000ruggedcom_win7200garrettcom_magnum_dx940e_firmwarevxworkshirschmann_msp40hirschmann_octopus_os3hirschmann_rsp30hirschmann_dragon_mach4000hirschmann_dragon_mach4500hirschmann_msp32hirschmann_rsp25hirschmann_rail_switch_power_smarthirschmann_grs1020hirschmann_eesx30hirschmann_rail_switch_power_litehirschmann_eagle20hirschmann_eagle30hirschmann_hiosruggedcom_win7025hirschmann_rspe30hirschmann_eagle_oneruggedcom_win7200_firmwarehirschmann_ees20hirschmann_red25ruggedcom_win7000_firmwarehirschmann_msp30hirschmann_grs1120n/a
CVE-2019-10922
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-1.49% / 80.31%
||
7 Day CHG~0.00%
Published-14 May, 2019 | 19:54
Updated-04 Aug, 2024 | 22:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 and newer (All versions), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 and newer (All versions). An attacker with network access to affected installations, which are configured without "Encrypted Communication", can execute arbitrary code. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected installation. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-simatic_winccsimatic_pcs_7SIMATIC WinCC V7.3 and newerSIMATIC PCS 7 V8.0 and earlierSIMATIC PCS 7 V8.1 and newerSIMATIC WinCC V7.2 and earlier
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-10938
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-0.49% / 64.43%
||
7 Day CHG~0.00%
Published-02 Aug, 2019 | 13:54
Updated-04 Aug, 2024 | 22:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIPROTEC 5 devices with CPU variants CP200 (All versions < V7.59), SIPROTEC 5 devices with CPU variants CP300 and CP100 (All versions < V8.01), Siemens Power Meters Series 9410 (All versions < V2.2.1), Siemens Power Meters Series 9810 (All versions). An unauthenticated attacker with network access to the device could potentially insert arbitrary code which is executed before firmware verification in the device. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-6md857sa867sj826md867um857sj857ut86siprotec_5_digsi_device_driver7sa877vk877ve856md897ut877sa827ut857sl827sd867sl867sd827sk857sk827ut827sd877sj867sl87Siemens Power Meters Series 9410Siemens Power Meters Series 9810SIPROTEC 5 devices with CPU variants CP300 and CP100SIPROTEC 5 devices with CPU variants CP200
CWE ID-CWE-284
Improper Access Control
CVE-2019-10919
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.4||CRITICAL
EPSS-0.75% / 72.10%
||
7 Day CHG~0.00%
Published-14 May, 2019 | 19:54
Updated-04 Aug, 2024 | 22:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Attackers with access to port 10005/tcp could perform device reconfigurations and obtain project files from the devices. The system manual recommends to protect access to this port. The security vulnerability could be exploited by an unauthenticated attacker with network access to port 10005/tcp. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-logo\!8_bm_firmwarelogo\!8_bmLOGO! 8 BM (incl. SIPLUS variants)
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2022-43514
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.7||HIGH
EPSS-1.07% / 76.87%
||
7 Day CHG~0.00%
Published-10 Jan, 2023 | 11:39
Updated-09 Apr, 2025 | 15:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Automation License Manager V5 (All versions), Automation License Manager V6 (All versions < V6.0 SP9 Upd4), TeleControl Server Basic V3 (All versions < V3.1.2). The affected component does not correctly validate the root path on folder related operations, allowing to modify files and folders outside the intended root directory. This could allow an unauthenticated remote attacker to execute file operations of files outside of the specified root folder. Chained with CVE-2022-43513 this could allow Remote Code Execution.

Action-Not Available
Vendor-Siemens AG
Product-automation_license_managerAutomation License Manager V5Automation License Manager V6TeleControl Server Basic V3
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2024-56336
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.5||CRITICAL
EPSS-0.10% / 27.89%
||
7 Day CHG~0.00%
Published-11 Mar, 2025 | 09:48
Updated-11 Mar, 2025 | 14:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINAMICS S200 (All versions with serial number beginning with SZVS8, SZVS9, SZVS0 or SZVSN and the FS number is 02). The affected device contains an unlocked bootloader. This security oversight enables attackers to inject malicious code, or install untrusted firmware. The intrinsic security features designed to protect against data manipulation and unauthorized access are compromised when the bootloader is not secured.

Action-Not Available
Vendor-Siemens AG
Product-SINAMICS S200
CWE ID-CWE-287
Improper Authentication
CVE-2019-0708
Matching Score-8
Assigner-Microsoft Corporation
ShareView Details
Matching Score-8
Assigner-Microsoft Corporation
CVSS Score-9.8||CRITICAL
EPSS-94.44% / 99.99%
||
7 Day CHG~0.00%
Published-16 May, 2019 | 18:17
Updated-30 Jul, 2025 | 01:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Known KEV||Action Due Date - 2022-05-03||Apply updates per vendor instructions.

A remote code execution vulnerability exists in Remote Desktop Services formerly known as Terminal Services when an unauthenticated attacker connects to the target system using RDP and sends specially crafted requests, aka 'Remote Desktop Services Remote Code Execution Vulnerability'.

Action-Not Available
Vendor-Microsoft CorporationSiemens AGHuawei Technologies Co., Ltd.
Product-ch240umaaxiom_multix_mrh1288_v2_firmwarerh5885_v3multix_pro_acssaxiom_vertix_solitaire_msyngo_lab_process_managerx6000multix_pro_acss_firmwareaxiom_multix_m_firmwaremultix_swing_firmwarerh5885_v3_firmwareoceanstor_hvs85tmultix_pro_p_firmwarebh622_v2_firmwareoceanstor_18500bh621_v2_firmwarerh2265_v2windows_7ch140bh620_v2aptio_firmwarech121oceanstor_18500_firmwarerh1288a_v2_firmwarerh2285h_v2ch221_firmwareespace_ecs_firmwaregtsoftx3000_firmwaresmc2.0_firmwarech242_v3centralinkmultix_top_acss_pmultix_proatellica_solutionch242uma_firmwarerh2288e_v2smc2.0rh2288h_v2rapidpoint_500_firmwarech221oceanstor_hvs85t_firmwarerh2288_v2lantisrh2285_v2_firmwaree6000_chassis_firmwareelog_firmwaremultix_top_pbh640_v2ch240_firmwarerh1288_v2seco_vsmviva_e_firmwarerh2485_v2rh2288_v2_firmwarech222_firmwarech140_firmwarevertix_solitaire_firmwarelantis_firmwarerh5885_v2ch220_firmwaremultix_swingaptiorapidpoint_500streamlab_firmwareagile_controller-campus_firmwaremobilett_xp_digital_firmwarerh2268_v2x8000axiom_vertix_md_trauma_firmwaremultix_pro_navy_firmwarerh1288a_v2x8000_firmwarerh5885_v2_firmwaregtsoftx3000vertix_solitaireatellica_solution_firmwarech220multix_pro_firmwarebh622_v2multix_top_acss_firmwareaxiom_vertix_md_traumarh2285_v2oceanstor_hvs88t_firmwarewindows_server_2008oceanstor_18800frh2265_v2_firmwarerh2268_v2_firmwareelogmultix_topbh621_v2rh2288a_v2_firmwaremobilett_xp_digitale6000_firmwarebh640_v2_firmwaremultix_pro_acss_p_firmwarech242_firmwarerh2285h_v2_firmwarerh2288e_v2_firmwareoceanstor_18800f_firmwareviva_ex6000_firmwarebh620_v2_firmwareespace_ecse6000centralink_firmwarech121_firmwaremultix_top_firmwaremultix_top_p_firmwareviva_twinrh2288a_v2multix_top_acssmultix_pro_acss_pe6000_chassismultix_pro_paxiom_vertix_solitaire_m_firmwareoceanstor_18800oceanstor_18800_firmwarech242_v3_firmwareagile_controller-campusrh2485_v2_firmwaremultix_top_acss_p_firmwareseco_vsm_firmwarestreamlabrh2288h_v2_firmwaremultix_pro_navych222oceanstor_hvs88tviva_twin_firmwareWindows ServerWindowsRemote Desktop Services
CWE ID-CWE-416
Use After Free
CVE-2023-24482
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-10||CRITICAL
EPSS-0.23% / 45.81%
||
7 Day CHG~0.00%
Published-14 Feb, 2023 | 10:36
Updated-20 Mar, 2025 | 16:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in COMOS V10.2 (All versions), COMOS V10.3.3.1 (All versions < V10.3.3.1.45), COMOS V10.3.3.2 (All versions < V10.3.3.2.33), COMOS V10.3.3.3 (All versions < V10.3.3.3.9), COMOS V10.3.3.4 (All versions < V10.3.3.4.6), COMOS V10.4.0.0 (All versions < V10.4.0.0.31), COMOS V10.4.1.0 (All versions < V10.4.1.0.32), COMOS V10.4.2.0 (All versions < V10.4.2.0.25). Cache validation service in COMOS is vulnerable to Structured Exception Handler (SEH) based buffer overflow. This could allow an attacker to execute arbitrary code on the target system or cause denial of service condition.

Action-Not Available
Vendor-Siemens AG
Product-comosCOMOS V10.3.3.1COMOS V10.3.3.3COMOS V10.3.3.4COMOS V10.3.3.2COMOS V10.4.2.0COMOS V10.2COMOS V10.4.0.0COMOS V10.4.1.0
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2024-47901
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-10||CRITICAL
EPSS-2.84% / 85.66%
||
7 Day CHG~0.00%
Published-23 Oct, 2024 | 14:21
Updated-30 Oct, 2024 | 15:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in InterMesh 7177 Hybrid 2.0 Subscriber (All versions < V8.2.12), InterMesh 7707 Fire Subscriber (All versions < V7.2.12 only if the IP interface is enabled (which is not the default configuration)). The web server of affected devices does not sanitize the input parameters in specific GET requests that allow for code execution on operating system level. In combination with other vulnerabilities (CVE-2024-47902, CVE-2024-47903, CVE-2024-47904) this could allow an unauthenticated remote attacker to execute arbitrary code with root privileges.

Action-Not Available
Vendor-Siemens AG
Product-intermesh_7707_fire_subscriberintermesh_7177_hybrid_2.0_subscriberintermesh_7707_fire_subscriber_firmwareInterMesh 7707 Fire SubscriberInterMesh 7177 Hybrid 2.0 Subscriberintermesh_7177_hybrid2.0_subscriberintermesh_7707_fire_subscriber
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-25752
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-2.82% / 85.59%
||
7 Day CHG~0.00%
Published-12 Apr, 2022 | 09:07
Updated-03 Aug, 2024 | 04:49
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The webserver of affected devices calculates session ids and nonces in an insecure manner. This could allow an unauthenticated remote attacker to brute-force session ids and hijack existing sessions.

Action-Not Available
Vendor-Siemens AG
Product-scalance_x308-2m_ts_firmwarescalance_x307-3_firmwarescalance_xr324-12mscalance_x310fescalance_x310fe_firmwarescalance_xr324-4m_eecscalance_x308-2ldscalance_x320-1fe_firmwaresiplus_net_scalance_x308-2scalance_xr324-4m_poe_firmwarescalance_x308-2scalance_x307-2eecscalance_xr324-4m_eec_firmwarescalance_x308-2_firmwarescalance_x304-2fe_firmwarescalance_xr324-12m_ts_firmwarescalance_x306-1ldfe_firmwarescalance_x307-2eec_firmwarescalance_x320-1-2ldfesiplus_net_scalance_x308-2_firmwarescalance_x308-2lh_firmwarescalance_x302-7eec_firmwarescalance_x308-2lhscalance_x307-3ld_firmwarescalance_x310scalance_x320-1-2ldfe_firmwarescalance_xr324-12m_firmwarescalance_x308-2m_poe_firmwarescalance_x308-2lh\+scalance_x310_firmwarescalance_x308-2m_poescalance_x308-2lh\+_firmwarescalance_x308-2ld_firmwarescalance_xr324-12m_tsscalance_x308-2m_tsscalance_x308-2m_firmwarescalance_x320-1fescalance_x408-2scalance_xr324-4m_poescalance_x306-1ldfescalance_x307-3ldscalance_x308-2mscalance_x408-2_firmwarescalance_x307-3scalance_x304-2fescalance_xr324-4m_poe_tsscalance_xr324-4m_poe_ts_firmwarescalance_x302-7eecSCALANCE XR324-12M TS (24V)SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)SCALANCE XR324-4M PoE (24V, ports on rear)SCALANCE XR324-4M EEC (24V, ports on front)SCALANCE XR324-12M (230V, ports on rear)SCALANCE X307-2 EEC (2x 24V, coated)SCALANCE XR324-4M PoE TS (24V, ports on front)SCALANCE X307-3SCALANCE X308-2MSCALANCE XR324-12M (24V, ports on rear)SCALANCE X308-2SCALANCE X308-2M PoESCALANCE X310FESCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)SCALANCE X308-2LH+SCALANCE X302-7 EEC (24V, coated)SCALANCE X307-2 EEC (230V, coated)SCALANCE X307-3LDSCALANCE X308-2LHSCALANCE XR324-4M EEC (24V, ports on rear)SCALANCE XR324-4M PoE (24V, ports on front)SCALANCE X302-7 EEC (2x 230V)SCALANCE X408-2SIPLUS NET SCALANCE X308-2SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)SCALANCE XR324-4M PoE (230V, ports on rear)SCALANCE X302-7 EEC (230V)SCALANCE X307-2 EEC (24V, coated)SCALANCE X307-2 EEC (2x 230V, coated)SCALANCE X302-7 EEC (2x 24V, coated)SCALANCE X308-2LDSCALANCE X307-2 EEC (24V)SCALANCE X304-2FESCALANCE X310SCALANCE X307-2 EEC (2x 24V)SCALANCE X307-2 EEC (230V)SCALANCE XR324-12M (24V, ports on front)SCALANCE X320-1 FESCALANCE X302-7 EEC (2x 24V)SCALANCE X306-1LD FESCALANCE X308-2M TSSCALANCE XR324-4M PoE (230V, ports on front)SCALANCE X307-2 EEC (2x 230V)SCALANCE X302-7 EEC (24V)SCALANCE X302-7 EEC (230V, coated)SCALANCE X302-7 EEC (2x 230V, coated)SCALANCE X320-1-2LD FESCALANCE XR324-4M EEC (2x 24V, ports on rear)SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)SCALANCE XR324-12M (230V, ports on front)SCALANCE XR324-4M EEC (2x 24V, ports on front)
CWE ID-CWE-330
Use of Insufficiently Random Values
CVE-2022-26314
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-1.55% / 80.70%
||
7 Day CHG~0.00%
Published-08 Mar, 2022 | 11:31
Updated-03 Aug, 2024 | 05:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Mendix Forgot Password Appstore module (All versions >= V3.3.0 < V3.5.1), Mendix Forgot Password Appstore module (Mendix 7 compatible) (All versions < V3.2.2). Initial passwords are generated in an insecure manner. This could allow an unauthenticated remote attacker to efficiently brute force passwords in specific situations.

Action-Not Available
Vendor-mendixSiemens AG
Product-forgot_passwordMendix Forgot Password Appstore module (Mendix 7 compatible)Mendix Forgot Password Appstore module
CWE ID-CWE-307
Improper Restriction of Excessive Authentication Attempts
  • Previous
  • 1
  • 2
  • 3
  • 4
  • 5
  • Next
Details not found