CVE-2021-33719

Summary
Assigner-siemens
Assigner Org ID-cec7a2ec-15b4-4faf-bd53-b40f371f3a77
Published At-14 Sep, 2021 | 10:47
Updated At-03 Aug, 2024 | 23:58
Rejected At-
Credits

A vulnerability has been identified in SIPROTEC 5 relays with CPU variants CP050 (All versions < V8.80), SIPROTEC 5 relays with CPU variants CP100 (All versions < V8.80), SIPROTEC 5 relays with CPU variants CP300 (All versions < V8.80). Specially crafted packets sent to port 4443/tcp could cause a Denial-of-Service condition or potential remote code execution.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
â–¼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:siemens
Assigner Org ID:cec7a2ec-15b4-4faf-bd53-b40f371f3a77
Published At:14 Sep, 2021 | 10:47
Updated At:03 Aug, 2024 | 23:58
Rejected At:
â–¼CVE Numbering Authority (CNA)

A vulnerability has been identified in SIPROTEC 5 relays with CPU variants CP050 (All versions < V8.80), SIPROTEC 5 relays with CPU variants CP100 (All versions < V8.80), SIPROTEC 5 relays with CPU variants CP300 (All versions < V8.80). Specially crafted packets sent to port 4443/tcp could cause a Denial-of-Service condition or potential remote code execution.

Affected Products
Vendor
Siemens AGSiemens
Product
SIPROTEC 5 relays with CPU variants CP050
Versions
Affected
  • All versions < V8.80
Vendor
Siemens AGSiemens
Product
SIPROTEC 5 relays with CPU variants CP100
Versions
Affected
  • All versions < V8.80
Vendor
Siemens AGSiemens
Product
SIPROTEC 5 relays with CPU variants CP300
Versions
Affected
  • All versions < V8.80
Problem Types
TypeCWE IDDescription
CWECWE-120CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Type: CWE
CWE ID: CWE-120
Description: CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://cert-portal.siemens.com/productcert/pdf/ssa-847986.pdf
x_refsource_MISC
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-847986.pdf
Resource:
x_refsource_MISC
â–¼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://cert-portal.siemens.com/productcert/pdf/ssa-847986.pdf
x_refsource_MISC
x_transferred
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-847986.pdf
Resource:
x_refsource_MISC
x_transferred
Information is not available yet
â–¼National Vulnerability Database (NVD)
nvd.nist.gov
Source:productcert@siemens.com
Published At:14 Sep, 2021 | 11:15
Updated At:16 Dec, 2021 | 18:25

A vulnerability has been identified in SIPROTEC 5 relays with CPU variants CP050 (All versions < V8.80), SIPROTEC 5 relays with CPU variants CP100 (All versions < V8.80), SIPROTEC 5 relays with CPU variants CP300 (All versions < V8.80). Specially crafted packets sent to port 4443/tcp could cause a Denial-of-Service condition or potential remote code execution.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.19.8CRITICAL
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Primary2.07.5HIGH
AV:N/AC:L/Au:N/C:P/I:P/A:P
Type: Primary
Version: 3.1
Base score: 9.8
Base severity: CRITICAL
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 2.0
Base score: 7.5
Base severity: HIGH
Vector:
AV:N/AC:L/Au:N/C:P/I:P/A:P
CPE Matches

Siemens AG
siemens
>>siprotec_5_with_cpu_variant_cp050>>Versions before 8.80(exclusive)
cpe:2.3:o:siemens:siprotec_5_with_cpu_variant_cp050:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>siprotec_5_with_cpu_variant_cp100>>Versions before 8.80(exclusive)
cpe:2.3:o:siemens:siprotec_5_with_cpu_variant_cp100:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>siprotec_5_with_cpu_variant_cp300>>Versions before 8.80(exclusive)
cpe:2.3:o:siemens:siprotec_5_with_cpu_variant_cp300:*:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-120Primaryproductcert@siemens.com
CWE ID: CWE-120
Type: Primary
Source: productcert@siemens.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://cert-portal.siemens.com/productcert/pdf/ssa-847986.pdfproductcert@siemens.com
Patch
Vendor Advisory
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-847986.pdf
Source: productcert@siemens.com
Resource:
Patch
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

1291Records found

CVE-2024-22039
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-10||CRITICAL
EPSS-8.04% / 91.93%
||
7 Day CHG~0.00%
Published-12 Mar, 2024 | 10:21
Updated-16 Dec, 2025 | 18:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Cerberus PRO EN Engineering Tool (All versions < IP8), Cerberus PRO EN Fire Panel FC72x IP6 (All versions < IP6 SR3), Cerberus PRO EN Fire Panel FC72x IP7 (All versions < IP7 SR5), Cerberus PRO EN X200 Cloud Distribution IP7 (All versions < V3.0.6602), Cerberus PRO EN X200 Cloud Distribution IP8 (All versions < V4.0.5016), Cerberus PRO EN X300 Cloud Distribution IP7 (All versions < V3.2.6601), Cerberus PRO EN X300 Cloud Distribution IP8 (All versions < V4.2.5015), Cerberus PRO UL Compact Panel FC922/924 (All versions < MP4), Cerberus PRO UL Engineering Tool (All versions < MP4), Cerberus PRO UL X300 Cloud Distribution (All versions < V4.3.0001), Desigo Fire Safety UL Compact Panel FC2025/2050 (All versions < MP4), Desigo Fire Safety UL Engineering Tool (All versions < MP4), Desigo Fire Safety UL X300 Cloud Distribution (All versions < V4.3.0001), Sinteso FS20 EN Engineering Tool (All versions < MP8), Sinteso FS20 EN Fire Panel FC20 MP6 (All versions < MP6 SR3), Sinteso FS20 EN Fire Panel FC20 MP7 (All versions < MP7 SR5), Sinteso FS20 EN X200 Cloud Distribution MP7 (All versions < V3.0.6602), Sinteso FS20 EN X200 Cloud Distribution MP8 (All versions < V4.0.5016), Sinteso FS20 EN X300 Cloud Distribution MP7 (All versions < V3.2.6601), Sinteso FS20 EN X300 Cloud Distribution MP8 (All versions < V4.2.5015), Sinteso Mobile (All versions < V3.0.0). The network communication library in affected systems does not validate the length of certain X.509 certificate attributes which might result in a stack-based buffer overflow. This could allow an unauthenticated remote attacker to execute code on the underlying operating system with root privileges.

Action-Not Available
Vendor-Siemens AG
Product-cerberus_pro_en_fire_panel_fc72xsinteso_mobilecerberus_pro_en_engineering_toolcerberus_pro_en_x300_cloud_distributionsinteso_fs20_en_x300_cloud_distributionsinteso_fs20_en_fire_panel_fc20sinteso_fs20_en_engineering_toolsinteso_fs20_en_x200_cloud_distributioncerberus_pro_en_x200_cloud_distributionDesigo Fire Safety UL Compact Panel FC2025/2050Sinteso FS20 EN Fire Panel FC20 MP6Sinteso MobileSinteso FS20 EN X200 Cloud Distribution MP8Sinteso FS20 EN X200 Cloud Distribution MP7Cerberus PRO EN X200 Cloud Distribution IP8Cerberus PRO EN X300 Cloud Distribution IP8Cerberus PRO UL X300 Cloud DistributionCerberus PRO EN X200 Cloud Distribution IP7Cerberus PRO UL Compact Panel FC922/924Cerberus PRO EN Fire Panel FC72x IP7Desigo Fire Safety UL X300 Cloud DistributionSinteso FS20 EN Engineering ToolCerberus PRO EN Engineering ToolSinteso FS20 EN X300 Cloud Distribution MP8Sinteso FS20 EN Fire Panel FC20 MP7Cerberus PRO EN X300 Cloud Distribution IP7Desigo Fire Safety UL Engineering ToolCerberus PRO UL Engineering ToolCerberus PRO EN Fire Panel FC72x IP6Sinteso FS20 EN X300 Cloud Distribution MP7cerberus_pro_en_x300_cloud_distributioncerberus_pro_ul_engineering_toolcerberus_pro_en_engineering_tooldesigo_fire_safety_ul_engineering_toolcerberus_pro_ul_compact_panelsinteso_fs20_en_x300_cloud_distributionsinteso_fs20_en_fire_panel_fc20cerberus_pro_ul_x300_cloudcerberus_pro_en_x200_cloud_distributionsinteso_mobilesinteso_fs20_en_x200_cloud_distributiondesigo_fire_safety_ul_compact_panelcerberus_pro_en_fire_panel_fc72x
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-24956
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-6.9||MEDIUM
EPSS-0.13% / 33.23%
||
7 Day CHG~0.00%
Published-11 Feb, 2025 | 10:29
Updated-24 Sep, 2025 | 00:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in OpenV2G (All versions < V0.9.6). The OpenV2G EXI parsing feature is missing a length check when parsing X509 serial numbers. Thus, an attacker could introduce a buffer overflow that leads to memory corruption.

Action-Not Available
Vendor-Siemens AG
Product-openv2gOpenV2G
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2020-7593
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-17.29% / 94.86%
||
7 Day CHG~0.00%
Published-14 Jul, 2020 | 13:18
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (V1.81.01 - V1.81.03), LOGO! 8 BM (incl. SIPLUS variants) (V1.82.01), LOGO! 8 BM (incl. SIPLUS variants) (V1.82.02). A buffer overflow vulnerability exists in the Web Server functionality of the device. A remote unauthenticated attacker could send a specially crafted HTTP request to cause a memory corruption, potentially resulting in remote code execution.

Action-Not Available
Vendor-Siemens AG
Product-logo\!_8_bmlogo\!_8_bm_firmwareLOGO! 8 BM (incl. SIPLUS variants)
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2019-12261
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-22.51% / 95.70%
||
7 Day CHG~0.00%
Published-09 Aug, 2019 | 20:27
Updated-04 Aug, 2024 | 23:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Wind River VxWorks 6.7 though 6.9 and vx7 has a Buffer Overflow in the TCP component (issue 3 of 4). This is an IPNET security vulnerability: TCP Urgent Pointer state confusion during connect() to a remote host.

Action-Not Available
Vendor-windriverbeldenn/aNetApp, Inc.Oracle CorporationSonicWall Inc.Siemens AG
Product-power_meter_9810_firmwarehirschmann_rsp20ruggedcom_win7025_firmwarehirschmann_ees25sonicoshirschmann_grs1030hirschmann_grs1142ruggedcom_win7018_firmwarehirschmann_rspe32hirschmann_grs1130garrettcom_magnum_dx940ehirschmann_rspe35hirschmann_eesx20hirschmann_rspe37ruggedcom_win7018power_meter_9410_firmwarehirschmann_grs1042siprotec_5_firmwareruggedcom_win7000ruggedcom_win7200hirschmann_rsp35garrettcom_magnum_dx940e_firmwaree-series_santricity_os_controllervxworkshirschmann_msp40hirschmann_octopus_os3hirschmann_rsp30communications_eaglehirschmann_dragon_mach4000hirschmann_dragon_mach4500hirschmann_msp32hirschmann_rsp25hirschmann_rail_switch_power_smarthirschmann_eesx30hirschmann_grs1020hirschmann_rail_switch_power_litehirschmann_eagle20hirschmann_eagle30hirschmann_hiosruggedcom_win7025hirschmann_rspe30hirschmann_eagle_oneruggedcom_win7200_firmwaresiprotec_5hirschmann_ees20hirschmann_red25power_meter_9410power_meter_9810ruggedcom_win7000_firmwarehirschmann_msp30hirschmann_grs1120n/a
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2019-12260
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-25.60% / 96.10%
||
7 Day CHG~0.00%
Published-09 Aug, 2019 | 20:18
Updated-04 Aug, 2024 | 23:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Wind River VxWorks 6.9 and vx7 has a Buffer Overflow in the TCP component (issue 2 of 4). This is an IPNET security vulnerability: TCP Urgent Pointer state confusion caused by a malformed TCP AO option.

Action-Not Available
Vendor-windriverbeldenn/aNetApp, Inc.Oracle CorporationSonicWall Inc.Siemens AG
Product-power_meter_9810_firmwarehirschmann_rsp20ruggedcom_win7025_firmwarehirschmann_ees25sonicoshirschmann_grs1030hirschmann_grs1142ruggedcom_win7018_firmwarehirschmann_rspe32hirschmann_grs1130garrettcom_magnum_dx940ehirschmann_rspe35hirschmann_eesx20hirschmann_rspe37ruggedcom_win7018power_meter_9410_firmwarehirschmann_grs1042siprotec_5_firmwareruggedcom_win7000ruggedcom_win7200hirschmann_rsp35garrettcom_magnum_dx940e_firmwaree-series_santricity_os_controllervxworkshirschmann_msp40hirschmann_octopus_os3hirschmann_rsp30communications_eaglehirschmann_dragon_mach4000hirschmann_dragon_mach4500hirschmann_msp32hirschmann_rsp25hirschmann_rail_switch_power_smarthirschmann_eesx30hirschmann_grs1020hirschmann_rail_switch_power_litehirschmann_eagle20hirschmann_eagle30hirschmann_hiosruggedcom_win7025hirschmann_rspe30hirschmann_eagle_oneruggedcom_win7200_firmwaresiprotec_5hirschmann_ees20hirschmann_red25power_meter_9410power_meter_9810ruggedcom_win7000_firmwarehirschmann_msp30hirschmann_grs1120n/a
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2019-12256
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-13.84% / 94.13%
||
7 Day CHG~0.00%
Published-09 Aug, 2019 | 17:57
Updated-04 Aug, 2024 | 23:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Wind River VxWorks 6.9 and vx7 has a Buffer Overflow in the IPv4 component. There is an IPNET security vulnerability: Stack overflow in the parsing of IPv4 packets’ IP options.

Action-Not Available
Vendor-windriverbeldenn/aNetApp, Inc.Siemens AGSonicWall Inc.
Product-power_meter_9810_firmwarehirschmann_rsp20ruggedcom_win7025_firmwarehirschmann_ees25sonicoshirschmann_grs1030hirschmann_grs1142ruggedcom_win7018_firmwarehirschmann_rspe32hirschmann_grs1130garrettcom_magnum_dx940ehirschmann_rspe35hirschmann_eesx20hirschmann_rspe37ruggedcom_win7018power_meter_9410_firmwarehirschmann_grs1042siprotec_5_firmwareruggedcom_win7000ruggedcom_win7200hirschmann_rsp35garrettcom_magnum_dx940e_firmwaree-series_santricity_os_controllervxworkshirschmann_msp40hirschmann_octopus_os3hirschmann_rsp30hirschmann_dragon_mach4000hirschmann_dragon_mach4500hirschmann_msp32hirschmann_rsp25hirschmann_rail_switch_power_smarthirschmann_eesx30hirschmann_grs1020hirschmann_rail_switch_power_litehirschmann_eagle20hirschmann_eagle30hirschmann_hiosruggedcom_win7025hirschmann_rspe30hirschmann_eagle_oneruggedcom_win7200_firmwaresiprotec_5hirschmann_ees20hirschmann_red25power_meter_9410power_meter_9810ruggedcom_win7000_firmwarehirschmann_msp30hirschmann_grs1120n/a
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2019-12255
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-76.86% / 98.92%
||
7 Day CHG~0.00%
Published-09 Aug, 2019 | 19:18
Updated-04 Aug, 2024 | 23:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Wind River VxWorks has a Buffer Overflow in the TCP component (issue 1 of 4). This is a IPNET security vulnerability: TCP Urgent Pointer = 0 that leads to an integer underflow.

Action-Not Available
Vendor-windriverbeldenn/aNetApp, Inc.Siemens AGSonicWall Inc.
Product-power_meter_9810_firmwarehirschmann_rsp20ruggedcom_win7025_firmwarehirschmann_ees25sonicoshirschmann_grs1030hirschmann_grs1142ruggedcom_win7018_firmwarehirschmann_rspe32hirschmann_grs1130garrettcom_magnum_dx940ehirschmann_rspe35hirschmann_eesx20hirschmann_rspe37ruggedcom_win7018power_meter_9410_firmwarehirschmann_grs1042siprotec_5_firmwareruggedcom_win7000ruggedcom_win7200hirschmann_rsp35garrettcom_magnum_dx940e_firmwaree-series_santricity_os_controllervxworkshirschmann_msp40hirschmann_octopus_os3hirschmann_rsp30hirschmann_dragon_mach4000hirschmann_dragon_mach4500hirschmann_msp32hirschmann_rsp25hirschmann_rail_switch_power_smarthirschmann_eesx30hirschmann_grs1020hirschmann_rail_switch_power_litehirschmann_eagle20hirschmann_eagle30hirschmann_hiosruggedcom_win7025hirschmann_rspe30hirschmann_eagle_oneruggedcom_win7200_firmwaresiprotec_5hirschmann_ees20hirschmann_red25power_meter_9410power_meter_9810ruggedcom_win7000_firmwarehirschmann_msp30hirschmann_grs1120n/a
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2022-36361
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-0.55% / 67.43%
||
7 Day CHG~0.00%
Published-11 Oct, 2022 | 00:00
Updated-20 Nov, 2024 | 14:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions). Affected devices do not properly validate the structure of TCP packets in several methods. This could allow an attacker to cause buffer overflows, get control over the instruction counter and run custom code.

Action-Not Available
Vendor-Siemens AG
Product-logo\!8_bm_fs-05logo\!8_bm_fs-05_firmwarelogo\!8_bmlogo\!_8_bm_firmwareLOGO! 230RCEoSIPLUS LOGO! 24CEoLOGO! 12/24RCELOGO! 24RCEoSIPLUS LOGO! 12/24RCEoLOGO! 24CEoSIPLUS LOGO! 24RCEoLOGO! 24RCESIPLUS LOGO! 24CELOGO! 12/24RCEoLOGO! 230RCESIPLUS LOGO! 230RCEoLOGO! 24CESIPLUS LOGO! 24RCESIPLUS LOGO! 12/24RCESIPLUS LOGO! 230RCE
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2023-24482
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-10||CRITICAL
EPSS-0.41% / 60.86%
||
7 Day CHG~0.00%
Published-14 Feb, 2023 | 10:36
Updated-20 Mar, 2025 | 16:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in COMOS V10.2 (All versions), COMOS V10.3.3.1 (All versions < V10.3.3.1.45), COMOS V10.3.3.2 (All versions < V10.3.3.2.33), COMOS V10.3.3.3 (All versions < V10.3.3.3.9), COMOS V10.3.3.4 (All versions < V10.3.3.4.6), COMOS V10.4.0.0 (All versions < V10.4.0.0.31), COMOS V10.4.1.0 (All versions < V10.4.1.0.32), COMOS V10.4.2.0 (All versions < V10.4.2.0.25). Cache validation service in COMOS is vulnerable to Structured Exception Handler (SEH) based buffer overflow. This could allow an attacker to execute arbitrary code on the target system or cause denial of service condition.

Action-Not Available
Vendor-Siemens AG
Product-comosCOMOS V10.3.3.1COMOS V10.3.3.3COMOS V10.3.3.4COMOS V10.3.3.2COMOS V10.4.2.0COMOS V10.2COMOS V10.4.0.0COMOS V10.4.1.0
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2022-37885
Matching Score-10
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-10
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-9.8||CRITICAL
EPSS-1.23% / 78.82%
||
7 Day CHG~0.00%
Published-07 Oct, 2022 | 00:00
Updated-03 Aug, 2024 | 10:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

There are buffer overflow vulnerabilities in multiple underlying services that could lead to unauthenticated remote code execution by sending specially crafted packets destined to the PAPI (Aruba Networks AP management protocol) UDP port (8211). Successful exploitation of these vulnerabilities results in the ability to execute arbitrary code as a privileged user on the underlying operating system of Aruba InstantOS 6.4.x: 6.4.4.8-4.2.4.20 and below; Aruba InstantOS 6.5.x: 6.5.4.23 and below; Aruba InstantOS 8.6.x: 8.6.0.18 and below; Aruba InstantOS 8.7.x: 8.7.1.9 and below; Aruba InstantOS 8.10.x: 8.10.0.1 and below; ArubaOS 10.3.x: 10.3.1.0 and below; Aruba has released upgrades for Aruba InnstantOS that address these security vulnerabilities.

Action-Not Available
Vendor-n/aSiemens AGAruba Networks
Product-arubaosscalance_w1750d_firmwareinstantscalance_w1750dAruba Access Points; 100 Series; 103 Series; 110 Series; 120 Series; 130 Series; 200 Series; 207 Series; 210 Series; 220 Series; 260 Series; 300 Series; 303 Series; 310 Series; 318 Series Hardened Access Points; 320 Series; 330 Series; 340 Series; 370 Series; 500 Series; 510 Series; 530 Series; 550 Series; 630 Series; 650 Series;
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2022-37887
Matching Score-10
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-10
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-9.8||CRITICAL
EPSS-1.29% / 79.34%
||
7 Day CHG~0.00%
Published-07 Oct, 2022 | 00:00
Updated-03 Aug, 2024 | 10:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

There are buffer overflow vulnerabilities in multiple underlying services that could lead to unauthenticated remote code execution by sending specially crafted packets destined to the PAPI (Aruba Networks AP management protocol) UDP port (8211). Successful exploitation of these vulnerabilities results in the ability to execute arbitrary code as a privileged user on the underlying operating system of Aruba InstantOS 6.4.x: 6.4.4.8-4.2.4.20 and below; Aruba InstantOS 6.5.x: 6.5.4.23 and below; Aruba InstantOS 8.6.x: 8.6.0.18 and below; Aruba InstantOS 8.7.x: 8.7.1.9 and below; Aruba InstantOS 8.10.x: 8.10.0.1 and below; ArubaOS 10.3.x: 10.3.1.0 and below; Aruba has released upgrades for Aruba InnstantOS that address these security vulnerabilities.

Action-Not Available
Vendor-n/aSiemens AGAruba Networks
Product-arubaosscalance_w1750d_firmwareinstantscalance_w1750dAruba Access Points: 100 Series; 103 Series; 110 Series; 120 Series; 130 Series; 200 Series; 207 Series; 210 Series; 220 Series; 260 Series; 300 Series; 303 Series; 310 Series; 318 Series Hardened Access Points; 320 Series; 330 Series; 340 Series; 370 Series; 500 Series; 510 Series; 530 Series; 550 Series; 630 Series; 650 Series;
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2022-37888
Matching Score-10
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-10
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-9.8||CRITICAL
EPSS-1.23% / 78.82%
||
7 Day CHG~0.00%
Published-06 Oct, 2022 | 00:00
Updated-03 Aug, 2024 | 10:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

There are buffer overflow vulnerabilities in multiple underlying services that could lead to unauthenticated remote code execution by sending specially crafted packets destined to the PAPI (Aruba Networks AP management protocol) UDP port (8211). Successful exploitation of these vulnerabilities results in the ability to execute arbitrary code as a privileged user on the underlying operating system of Aruba InstantOS 6.4.x: 6.4.4.8-4.2.4.20 and below; Aruba InstantOS 6.5.x: 6.5.4.23 and below; Aruba InstantOS 8.6.x: 8.6.0.18 and below; Aruba InstantOS 8.7.x: 8.7.1.9 and below; Aruba InstantOS 8.10.x: 8.10.0.1 and below; ArubaOS 10.3.x: 10.3.1.0 and below; Aruba has released upgrades for Aruba InnstantOS that address these security vulnerabilities.

Action-Not Available
Vendor-n/aSiemens AGAruba Networks
Product-instantap-334ap-505ap-514ap-315iap-315ap-103ap-115iap-204arubaosap-114scalance_w1750d_firmwareap-120ap-370ap-214ap-635ap-224ap-555iap-225ap-225iap-304iap-224iap-114ap-215ap-135ap-304ap-535ap-534iap-318ap-121ap-205iap-325ap-204ap-324ap-515iap-207iap-324ap-207ap-303ap-314rap-109scalance_w1750dap-504ap-325ap-655iap-103ap-340iap-205ap-130iap-305iap-314iap-334ap-305rap-108iap-115ap-318Aruba Access Points: 100 Series; 103 Series; 110 Series; 120 Series; 130 Series; 200 Series; 207 Series; 210 Series; 220 Series; 260 Series; 300 Series; 303 Series; 310 Series; 318 Series Hardened Access Points; 320 Series; 330 Series; 340 Series; 370 Series; 500 Series; 510 Series; 530 Series; 550 Series; 630 Series; 650 Series;
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2023-43504
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-9.6||CRITICAL
EPSS-0.23% / 45.64%
||
7 Day CHG~0.00%
Published-14 Nov, 2023 | 11:03
Updated-08 Jan, 2025 | 16:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in COMOS (All versions < V10.4.4). Ptmcast executable used for testing cache validation service in affected application is vulnerable to Structured Exception Handler (SEH) based buffer overflow. This could allow an attacker to execute arbitrary code on the target system or cause denial of service condition.

Action-Not Available
Vendor-Siemens AG
Product-comosCOMOS
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2022-37886
Matching Score-10
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-10
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-9.8||CRITICAL
EPSS-1.23% / 78.82%
||
7 Day CHG~0.00%
Published-07 Oct, 2022 | 00:00
Updated-03 Aug, 2024 | 10:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

There are buffer overflow vulnerabilities in multiple underlying services that could lead to unauthenticated remote code execution by sending specially crafted packets destined to the PAPI (Aruba Networks AP management protocol) UDP port (8211). Successful exploitation of these vulnerabilities results in the ability to execute arbitrary code as a privileged user on the underlying operating system of Aruba InstantOS 6.4.x: 6.4.4.8-4.2.4.20 and below; Aruba InstantOS 6.5.x: 6.5.4.23 and below; Aruba InstantOS 8.6.x: 8.6.0.18 and below; Aruba InstantOS 8.7.x: 8.7.1.9 and below; Aruba InstantOS 8.10.x: 8.10.0.1 and below; ArubaOS 10.3.x: 10.3.1.0 and below; Aruba has released upgrades for Aruba InnstantOS that address these security vulnerabilities.

Action-Not Available
Vendor-n/aSiemens AGAruba Networks
Product-arubaosscalance_w1750d_firmwareinstantscalance_w1750dAruba Access Points: 100 Series; 103 Series; 110 Series; 120 Series; 130 Series; 200 Series; 207 Series; 210 Series; 220 Series; 260 Series; 300 Series; 303 Series; 310 Series; 318 Series Hardened Access Points; 320 Series; 330 Series; 340 Series; 370 Series; 500 Series; 510 Series; 530 Series; 550 Series; 630 Series; 650 Series;
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2022-37889
Matching Score-10
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-10
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-9.8||CRITICAL
EPSS-1.23% / 78.82%
||
7 Day CHG~0.00%
Published-07 Oct, 2022 | 00:00
Updated-03 Aug, 2024 | 10:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

There are buffer overflow vulnerabilities in multiple underlying services that could lead to unauthenticated remote code execution by sending specially crafted packets destined to the PAPI (Aruba Networks AP management protocol) UDP port (8211). Successful exploitation of these vulnerabilities results in the ability to execute arbitrary code as a privileged user on the underlying operating system of Aruba InstantOS 6.4.x: 6.4.4.8-4.2.4.20 and below; Aruba InstantOS 6.5.x: 6.5.4.23 and below; Aruba InstantOS 8.6.x: 8.6.0.18 and below; Aruba InstantOS 8.7.x: 8.7.1.9 and below; Aruba InstantOS 8.10.x: 8.10.0.1 and below; ArubaOS 10.3.x: 10.3.1.0 and below; Aruba has released upgrades for Aruba InnstantOS that address these security vulnerabilities.

Action-Not Available
Vendor-n/aSiemens AGAruba Networks
Product-arubaosscalance_w1750d_firmwareinstantscalance_w1750dAruba Access Points: 100 Series; 103 Series; 110 Series; 120 Series; 130 Series; 200 Series; 207 Series; 210 Series; 220 Series; 260 Series; 300 Series; 303 Series; 310 Series; 318 Series Hardened Access Points; 320 Series; 330 Series; 340 Series; 370 Series; 500 Series; 510 Series; 530 Series; 550 Series; 630 Series; 650 Series;
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2019-5319
Matching Score-10
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-10
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-9.8||CRITICAL
EPSS-1.73% / 82.09%
||
7 Day CHG~0.00%
Published-30 Mar, 2021 | 01:45
Updated-04 Aug, 2024 | 19:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A remote buffer overflow vulnerability was discovered in some Aruba Instant Access Point (IAP) products in version(s): Aruba Instant 6.4.x: 6.4.4.8-4.2.4.17 and below; Aruba Instant 6.5.x: 6.5.4.16 and below; Aruba Instant 8.3.x: 8.3.0.12 and below; Aruba Instant 8.5.x: 8.5.0.6 and below; Aruba Instant 8.6.x: 8.6.0.2 and below. Aruba has released patches for Aruba Instant that address this security vulnerability.

Action-Not Available
Vendor-n/aSiemens AGAruba Networks
Product-scalance_w1750d_firmwareinstantscalance_w1750dAruba Instant Access Points
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2021-31895
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.1||HIGH
EPSS-1.16% / 78.27%
||
7 Day CHG~0.00%
Published-13 Jul, 2021 | 11:02
Updated-14 Oct, 2025 | 10:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM i800 (All versions < V4.3.7), RUGGEDCOM i801 (All versions < V4.3.7), RUGGEDCOM i802 (All versions < V4.3.7), RUGGEDCOM i803 (All versions < V4.3.7), RUGGEDCOM M2100 (All versions < V4.3.7), RUGGEDCOM M2200 (All versions < V4.3.7), RUGGEDCOM M969 (All versions < V4.3.7), RUGGEDCOM RMC30 (All versions < V4.3.7), RUGGEDCOM RMC8388 V4.X (All versions < V4.3.7), RUGGEDCOM RMC8388 V5.X (All versions < V5.5.4), RUGGEDCOM RP110 (All versions < V4.3.7), RUGGEDCOM RS1600 (All versions < V4.3.7), RUGGEDCOM RS1600F (All versions < V4.3.7), RUGGEDCOM RS1600T (All versions < V4.3.7), RUGGEDCOM RS400 (All versions < V4.3.7), RUGGEDCOM RS401 (All versions < V4.3.7), RUGGEDCOM RS416 (All versions < V4.3.7), RUGGEDCOM RS416P (All versions < V4.3.7), RUGGEDCOM RS416Pv2 V4.X (All versions < V4.3.7), RUGGEDCOM RS416Pv2 V5.X (All versions < V5.5.4), RUGGEDCOM RS416v2 V4.X (All versions < V4.3.7), RUGGEDCOM RS416v2 V5.X (All versions < 5.5.4), RUGGEDCOM RS8000 (All versions < V4.3.7), RUGGEDCOM RS8000A (All versions < V4.3.7), RUGGEDCOM RS8000H (All versions < V4.3.7), RUGGEDCOM RS8000T (All versions < V4.3.7), RUGGEDCOM RS900 (32M) V4.X (All versions < V4.3.7), RUGGEDCOM RS900 (32M) V5.X (All versions < V5.5.4), RUGGEDCOM RS900G (All versions < V4.3.7), RUGGEDCOM RS900G (32M) V4.X (All versions < V4.3.7), RUGGEDCOM RS900G (32M) V5.X (All versions < V5.5.4), RUGGEDCOM RS900GP (All versions < V4.3.7), RUGGEDCOM RS900L (All versions < V4.3.7), RUGGEDCOM RS900W (All versions < V4.3.7), RUGGEDCOM RS910 (All versions < V4.3.7), RUGGEDCOM RS910L (All versions < V4.3.7), RUGGEDCOM RS910W (All versions < V4.3.7), RUGGEDCOM RS920L (All versions < V4.3.7), RUGGEDCOM RS920W (All versions < V4.3.7), RUGGEDCOM RS930L (All versions < V4.3.7), RUGGEDCOM RS930W (All versions < V4.3.7), RUGGEDCOM RS940G (All versions < V4.3.7), RUGGEDCOM RS969 (All versions < V4.3.7), RUGGEDCOM RSG2100 (All versions < V4.3.7), RUGGEDCOM RSG2100 (32M) V4.X (All versions < V4.3.7), RUGGEDCOM RSG2100 (32M) V5.X (All versions < V5.5.4), RUGGEDCOM RSG2100P (All versions < V4.3.7), RUGGEDCOM RSG2100P (32M) V4.X (All versions < V4.3.7), RUGGEDCOM RSG2100P (32M) V5.X (All versions < V5.5.4), RUGGEDCOM RSG2200 (All versions < V4.3.7), RUGGEDCOM RSG2288 V4.X (All versions < V4.3.7), RUGGEDCOM RSG2288 V5.X (All versions < V5.5.4), RUGGEDCOM RSG2300 V4.X (All versions < V4.3.7), RUGGEDCOM RSG2300 V5.X (All versions < V5.5.4), RUGGEDCOM RSG2300P V4.X (All versions < V4.3.7), RUGGEDCOM RSG2300P V5.X (All versions < V5.5.4), RUGGEDCOM RSG2488 V4.X (All versions < V4.3.7), RUGGEDCOM RSG2488 V5.X (All versions < V5.5.4), RUGGEDCOM RSG907R (All versions < V5.5.4), RUGGEDCOM RSG908C (All versions < V5.5.4), RUGGEDCOM RSG909R (All versions < V5.5.4), RUGGEDCOM RSG910C (All versions < V5.5.4), RUGGEDCOM RSG920P V4.X (All versions < V4.3.7), RUGGEDCOM RSG920P V5.X (All versions < V5.5.4), RUGGEDCOM RSL910 (All versions < V5.5.4), RUGGEDCOM RST2228 (All versions < V5.5.4), RUGGEDCOM RST2228P (All versions < V5.5.4), RUGGEDCOM RST916C (All versions < V5.5.4), RUGGEDCOM RST916P (All versions < V5.5.4). The DHCP client in affected devices fails to properly sanitize incoming DHCP packets. This could allow an unauthenticated remote attacker to cause memory to be overwritten, potentially allowing remote code execution.

Action-Not Available
Vendor-Siemens AG
Product-ruggedcom_ros_rs900ruggedcom_ros_m2100ruggedcom_rst916pruggedcom_ros_rs900lruggedcom_ros_rs910wruggedcom_ros_rs969ruggedcom_i802ruggedcom_ros_rs920lruggedcom_rsg2300pruggedcom_ros_rs910lruggedcom_rs910lruggedcom_rmc30ruggedcom_ros_rmc30ruggedcom_rs900wruggedcom_ros_rsg2200ruggedcom_ros_rsg900rruggedcom_rs8000truggedcom_rs940gruggedcom_ros_i803ruggedcom_m969ruggedcom_rs930lruggedcom_ros_m2200ruggedcom_rsg2100ruggedcom_ros_rsg2288ruggedcom_rsg2100pruggedcom_ros_rmcruggedcom_rsg900gruggedcom_rs8000ruggedcom_rs910wruggedcom_ros_rsg900ruggedcom_ros_rsl910ruggedcom_ros_rs416ruggedcom_ros_rs930wruggedcom_ros_m969ruggedcom_ros_rsg2300pruggedcom_i803ruggedcom_ros_rsg900gruggedcom_ros_rsg920pruggedcom_rsg900rruggedcom_ros_rp110ruggedcom_rs401ruggedcom_rs900ruggedcom_ros_rmc8388ruggedcom_ros_rs900gruggedcom_rmc41ruggedcom_rs900gruggedcom_rs910ruggedcom_ros_rsg2100ruggedcom_rsg920pruggedcom_rp110ruggedcom_ros_rmc41ruggedcom_ros_rsg2300ruggedcom_ros_i802ruggedcom_rs416ruggedcom_ros_rst916cruggedcom_rs8000hruggedcom_rs920lruggedcom_ros_rst916pruggedcom_rmc8388ruggedcom_ros_rs416v2ruggedcom_ros_rs8000ruggedcom_ros_rs8000aruggedcom_ros_rst2228ruggedcom_rs400ruggedcom_ros_rs900wruggedcom_ros_rs930lruggedcom_ros_rs940gruggedcom_rs969ruggedcom_m2100ruggedcom_ros_i800ruggedcom_rsg2288ruggedcom_rsg900ruggedcom_m2200ruggedcom_ros_rs920wruggedcom_ros_rs401ruggedcom_ros_rs910ruggedcom_rsg2300ruggedcom_rsg2488ruggedcom_rsg900cruggedcom_ros_rsg900cruggedcom_rsg2200ruggedcom_rmc20ruggedcom_rs416v2ruggedcom_ros_rsg2488ruggedcom_ros_rsg2100pruggedcom_rmc40ruggedcom_rs930wruggedcom_rs920wruggedcom_rs900lruggedcom_ros_rs8000truggedcom_rmcruggedcom_rs900gpruggedcom_ros_rs400ruggedcom_rs8000aruggedcom_ros_rmc40ruggedcom_ros_rs900gpruggedcom_ros_rs8000hruggedcom_ros_rmc20ruggedcom_i801ruggedcom_rst2228ruggedcom_ros_i801ruggedcom_rsl910ruggedcom_i800ruggedcom_rst916cRUGGEDCOM RST916PRUGGEDCOM RSG2488 V4.XRUGGEDCOM RS969RUGGEDCOM RS900GRUGGEDCOM i801RUGGEDCOM RSG920P V5.XRUGGEDCOM RS930LRUGGEDCOM RS1600TRUGGEDCOM RS401RUGGEDCOM RS900G (32M) V5.XRUGGEDCOM RSG920P V4.XRUGGEDCOM RS920LRUGGEDCOM M2200RUGGEDCOM RSG910CRUGGEDCOM RS416Pv2 V4.XRUGGEDCOM RSG2100PRUGGEDCOM RSG2288 V4.XRUGGEDCOM RS8000TRUGGEDCOM RS8000HRUGGEDCOM RS900 (32M) V4.XRUGGEDCOM M2100RUGGEDCOM RSG2100 (32M) V4.XRUGGEDCOM RSG2300 V4.XRUGGEDCOM RS416Pv2 V5.XRUGGEDCOM RSG2300 V5.XRUGGEDCOM RS8000RUGGEDCOM RS900LRUGGEDCOM RMC8388 V5.XRUGGEDCOM RS400RUGGEDCOM RS910LRUGGEDCOM RSG907RRUGGEDCOM RSL910RUGGEDCOM RS900GPRUGGEDCOM RST916CRUGGEDCOM RSG2200RUGGEDCOM RSG2488 V5.XRUGGEDCOM RS940GRUGGEDCOM RMC8388 V4.XRUGGEDCOM RSG2100 (32M) V5.XRUGGEDCOM RSG2100P (32M) V4.XRUGGEDCOM RS910WRUGGEDCOM RS910RUGGEDCOM RS1600FRUGGEDCOM RS900G (32M) V4.XRUGGEDCOM RSG2100RUGGEDCOM RMC30RUGGEDCOM RSG2288 V5.XRUGGEDCOM RSG2300P V4.XRUGGEDCOM RSG908CRUGGEDCOM RS416v2 V4.XRUGGEDCOM i800RUGGEDCOM RSG909RRUGGEDCOM i802RUGGEDCOM RP110RUGGEDCOM RS1600RUGGEDCOM RS416PRUGGEDCOM RST2228PRUGGEDCOM RSG2100P (32M) V5.XRUGGEDCOM RS8000ARUGGEDCOM RS416v2 V5.XRUGGEDCOM RS920WRUGGEDCOM M969RUGGEDCOM RS900 (32M) V5.XRUGGEDCOM RST2228RUGGEDCOM RS416RUGGEDCOM RS930WRUGGEDCOM RSG2300P V5.XRUGGEDCOM i803RUGGEDCOM RS900W
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-27391
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-2.86% / 85.93%
||
7 Day CHG~0.00%
Published-14 Sep, 2021 | 10:47
Updated-23 Apr, 2025 | 19:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in APOGEE MBC (PPC) (P2 Ethernet) (All versions >= V2.6.3), APOGEE MEC (PPC) (P2 Ethernet) (All versions >= V2.6.3), APOGEE PXC Compact (BACnet) (All versions < V3.5.3), APOGEE PXC Compact (P2 Ethernet) (All versions >= V2.8), APOGEE PXC Modular (BACnet) (All versions < V3.5.3), APOGEE PXC Modular (P2 Ethernet) (All versions >= V2.8), TALON TC Compact (BACnet) (All versions < V3.5.3), TALON TC Modular (BACnet) (All versions < V3.5.3). The web server of affected devices lacks proper bounds checking when parsing the Host parameter in HTTP requests, which could lead to a buffer overflow. An unauthenticated remote attacker could exploit this vulnerability to execute arbitrary code on the device with root privileges.

Action-Not Available
Vendor-Siemens AG
Product-apogee_pxc_compact_\(p2_ethernet\)apogee_pxc_modular_\(bacnet\)_firmwareapogee_pxc_compact_\(p2_ethernet\)_firmwaretalon_tc_compact_\(bacnet\)apogee_mbc_\(ppc\)_\(p2_ethernet\)_firmwareapogee_pxc_bacnet_automation_controllerapogee_mbc_\(ppc\)_\(p2_ethernet\)apogee_pxc_bacnet_automation_controller_firmwareapogee_mec_\(ppc\)_\(p2_ethernet\)talon_tc_compact_\(bacnet\)_firmwareapogee_pxc_modular_\(p2_ethernet\)talon_tc_modular_\(bacnet\)apogee_pxc_modular_\(p2_ethernet\)_firmwareapogee_pxc_modular_\(bacnet\)apogee_mec_\(ppc\)_\(p2_ethernet\)_firmwaretalon_tc_modular_\(bacnet\)_firmwareAPOGEE PXC Modular (P2 Ethernet)APOGEE PXC Compact (BACnet)APOGEE MEC (PPC) (P2 Ethernet)APOGEE PXC Modular (BACnet)APOGEE MBC (PPC) (P2 Ethernet)TALON TC Modular (BACnet)APOGEE PXC Compact (P2 Ethernet)TALON TC Compact (BACnet)
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2021-25149
Matching Score-10
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-10
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-9.8||CRITICAL
EPSS-0.71% / 71.89%
||
7 Day CHG~0.00%
Published-29 Mar, 2021 | 23:58
Updated-03 Aug, 2024 | 19:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A remote buffer overflow vulnerability was discovered in some Aruba Instant Access Point (IAP) products in version(s): Aruba Instant 6.4.x: 6.4.4.8-4.2.4.17 and below; Aruba Instant 6.5.x: 6.5.4.16 and below; Aruba Instant 8.3.x: 8.3.0.12 and below; Aruba Instant 8.5.x: 8.5.0.6 and below; Aruba Instant 8.6.x: 8.6.0.2 and below. Aruba has released patches for Aruba Instant that address this security vulnerability.

Action-Not Available
Vendor-n/aSiemens AGAruba Networks
Product-scalance_w1750d_firmwareinstantscalance_w1750dAruba Instant Access Points
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2022-37890
Matching Score-10
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-10
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-9.8||CRITICAL
EPSS-1.88% / 82.80%
||
7 Day CHG~0.00%
Published-07 Oct, 2022 | 00:00
Updated-03 Aug, 2024 | 10:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Unauthenticated buffer overflow vulnerabilities exist within the Aruba InstantOS and ArubaOS 10 web management interface. Successful exploitation results in the execution of arbitrary commands on the underlying operating system of Aruba InstantOS 6.4.x: 6.4.4.8-4.2.4.20 and below; Aruba InstantOS 6.5.x: 6.5.4.23 and below; Aruba InstantOS 8.6.x: 8.6.0.18 and below; Aruba InstantOS 8.7.x: 8.7.1.9 and below; Aruba InstantOS 8.10.x: 8.10.0.1 and below; ArubaOS 10.3.x: 10.3.1.0 and below; Aruba has released upgrades for Aruba InnstantOS that address these security vulnerabilities.

Action-Not Available
Vendor-n/aSiemens AGAruba Networks
Product-arubaosscalance_w1750d_firmwareinstantscalance_w1750dAruba Access Points: 100 Series; 103 Series; 110 Series; 120 Series; 130 Series; 200 Series; 207 Series; 210 Series; 220 Series; 260 Series; 300 Series; 303 Series; 310 Series; 318 Series Hardened Access Points; 320 Series; 330 Series; 340 Series; 370 Series; 500 Series; 510 Series; 530 Series; 550 Series; 630 Series; 650 Series;
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2021-37716
Matching Score-10
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-10
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-9.8||CRITICAL
EPSS-1.58% / 81.25%
||
7 Day CHG~0.00%
Published-07 Sep, 2021 | 12:02
Updated-04 Aug, 2024 | 01:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A remote buffer overflow vulnerability was discovered in Aruba SD-WAN Software and Gateways; Aruba Operating System Software version(s): Prior to 8.6.0.4-2.2.0.4; Prior to 8.7.1.2, 8.6.0.8, 8.5.0.12, 8.3.0.15. Aruba has released patches for Aruba SD-WAN Software and Gateways and ArubaOS that address this security vulnerability.

Action-Not Available
Vendor-n/aSiemens AGAruba Networks
Product-arubaossd-wanscalance_w1750d_firmwarescalance_w1750dAruba SD-WAN Software and Gateways; Aruba Operating System Software
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2021-37726
Matching Score-10
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-10
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-9.8||CRITICAL
EPSS-1.32% / 79.53%
||
7 Day CHG~0.00%
Published-12 Oct, 2021 | 14:06
Updated-04 Aug, 2024 | 01:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A remote buffer overflow vulnerability was discovered in HPE Aruba Instant (IAP) version(s): Aruba Instant 8.7.x.x: 8.7.0.0 through 8.7.1.2. Aruba has released patches for Aruba Instant (IAP) that address this security vulnerability.

Action-Not Available
Vendor-n/aSiemens AGAruba Networks
Product-aruba_instantscalance_w1750d_firmwarescalance_w1750dHPE Aruba Instant (IAP)
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2020-10042
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-1.30% / 79.37%
||
7 Day CHG~0.00%
Published-14 Jul, 2020 | 13:18
Updated-04 Aug, 2024 | 10:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). A buffer overflow in various positions of the web application might enable an attacker with access to the web application to execute arbitrary code over the network.

Action-Not Available
Vendor-Siemens AG
Product-sicam_t_firmwaresicam_mmusicam_sgu_firmwaresicam_mmu_firmwaresicam_sgusicam_tSICAM TSICAM MMUSICAM SGU
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2022-37891
Matching Score-10
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-10
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-9.8||CRITICAL
EPSS-1.88% / 82.80%
||
7 Day CHG~0.00%
Published-07 Oct, 2022 | 00:00
Updated-03 Aug, 2024 | 10:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Unauthenticated buffer overflow vulnerabilities exist within the Aruba InstantOS and ArubaOS 10 web management interface. Successful exploitation results in the execution of arbitrary commands on the underlying operating system of Aruba InstantOS 6.4.x: 6.4.4.8-4.2.4.20 and below; Aruba InstantOS 6.5.x: 6.5.4.23 and below; Aruba InstantOS 8.6.x: 8.6.0.18 and below; Aruba InstantOS 8.7.x: 8.7.1.9 and below; Aruba InstantOS 8.10.x: 8.10.0.1 and below; ArubaOS 10.3.x: 10.3.1.0 and below; Aruba has released upgrades for Aruba InnstantOS that address these security vulnerabilities.

Action-Not Available
Vendor-n/aSiemens AGAruba Networks
Product-arubaosscalance_w1750d_firmwareinstantscalance_w1750dAruba Access Points: 100 Series; 103 Series; 110 Series; 120 Series; 130 Series; 200 Series; 207 Series; 210 Series; 220 Series; 260 Series; 300 Series; 303 Series; 310 Series; 318 Series Hardened Access Points; 320 Series; 330 Series; 340 Series; 370 Series; 500 Series; 510 Series; 530 Series; 550 Series; 630 Series; 650 Series;
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2024-23813
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.3||HIGH
EPSS-0.14% / 34.78%
||
7 Day CHG~0.00%
Published-13 Feb, 2024 | 09:00
Updated-09 May, 2025 | 18:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Polarion ALM (All versions < V2404.0). The REST API endpoints of doorsconnector of the affected product lacks proper authentication. An unauthenticated attacker could access the endpoints, and potentially execute code.

Action-Not Available
Vendor-Siemens AG
Product-polarion_almPolarion ALM
CWE ID-CWE-287
Improper Authentication
CVE-2024-23810
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.76% / 72.87%
||
7 Day CHG~0.00%
Published-13 Feb, 2024 | 09:00
Updated-09 May, 2025 | 18:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEC NMS (All versions < V2.0 SP1). The affected application is vulnerable to SQL injection. This could allow an unauthenticated remote attacker to execute arbitrary SQL queries on the server database.

Action-Not Available
Vendor-Siemens AG
Product-sinec_nmsSINEC NMS
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2024-23816
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-1.91% / 82.97%
||
7 Day CHG~0.00%
Published-13 Feb, 2024 | 09:00
Updated-09 May, 2025 | 18:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Location Intelligence Perpetual Large (9DE5110-8CA13-1AX0) (All versions < V4.3), Location Intelligence Perpetual Medium (9DE5110-8CA12-1AX0) (All versions < V4.3), Location Intelligence Perpetual Non-Prod (9DE5110-8CA10-1AX0) (All versions < V4.3), Location Intelligence Perpetual Small (9DE5110-8CA11-1AX0) (All versions < V4.3), Location Intelligence SUS Large (9DE5110-8CA13-1BX0) (All versions < V4.3), Location Intelligence SUS Medium (9DE5110-8CA12-1BX0) (All versions < V4.3), Location Intelligence SUS Non-Prod (9DE5110-8CA10-1BX0) (All versions < V4.3), Location Intelligence SUS Small (9DE5110-8CA11-1BX0) (All versions < V4.3). Affected products use a hard-coded secret value for the computation of a Keyed-Hash Message Authentication Code. This could allow an unauthenticated remote attacker to gain full administrative access to the application.

Action-Not Available
Vendor-Siemens AG
Product-location_intelligenceLocation Intelligence SUS Non-ProdLocation Intelligence Perpetual LargeLocation Intelligence Perpetual MediumLocation Intelligence Perpetual Non-ProdLocation Intelligence SUS SmallLocation Intelligence Perpetual SmallLocation Intelligence SUS MediumLocation Intelligence SUS Large
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2024-54092
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.3||CRITICAL
EPSS-0.48% / 64.49%
||
7 Day CHG~0.00%
Published-08 Apr, 2025 | 08:22
Updated-08 Jul, 2025 | 11:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Industrial Edge Device Kit - arm64 V1.17 (All versions), Industrial Edge Device Kit - arm64 V1.18 (All versions), Industrial Edge Device Kit - arm64 V1.19 (All versions), Industrial Edge Device Kit - arm64 V1.20 (All versions < V1.20.2-1), Industrial Edge Device Kit - arm64 V1.21 (All versions < V1.21.1-1), Industrial Edge Device Kit - x86-64 V1.17 (All versions), Industrial Edge Device Kit - x86-64 V1.18 (All versions), Industrial Edge Device Kit - x86-64 V1.19 (All versions), Industrial Edge Device Kit - x86-64 V1.20 (All versions < V1.20.2-1), Industrial Edge Device Kit - x86-64 V1.21 (All versions < V1.21.1-1), Industrial Edge Own Device (IEOD) (All versions < V1.21.1-1-a), Industrial Edge Virtual Device (All versions < V1.21.1-1-a), SCALANCE LPE9413 (6GK5998-3GS01-2AC2) (All versions < V2.1), SIMATIC IPC BX-39A Industrial Edge Device (All versions < V3.0), SIMATIC IPC BX-59A Industrial Edge Device (All versions < V3.0), SIMATIC IPC127E Industrial Edge Device (All versions < V3.0), SIMATIC IPC227E Industrial Edge Device (All versions < V3.0), SIMATIC IPC427E Industrial Edge Device (All versions < V3.0), SIMATIC IPC847E Industrial Edge Device (All versions < V3.0). Affected devices do not properly enforce user authentication on specific API endpoints when identity federation is used. This could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Successful exploitation requires that identity federation is currently or has previously been used and the attacker has learned the identity of a legitimate user.

Action-Not Available
Vendor-Siemens AG
Product-SIMATIC IPC227E Industrial Edge DeviceSIMATIC IPC847E Industrial Edge DeviceIndustrial Edge Device Kit - arm64 V1.17Industrial Edge Device Kit - arm64 V1.19Industrial Edge Device Kit - arm64 V1.18Industrial Edge Device Kit - x86-64 V1.17SIMATIC IPC427E Industrial Edge DeviceIndustrial Edge Device Kit - x86-64 V1.21SIMATIC IPC BX-39A Industrial Edge DeviceIndustrial Edge Device Kit - x86-64 V1.19Industrial Edge Device Kit - x86-64 V1.18Industrial Edge Own Device (IEOD)Industrial Edge Device Kit - x86-64 V1.20SIMATIC IPC127E Industrial Edge DeviceIndustrial Edge Device Kit - arm64 V1.21SCALANCE LPE9413SIMATIC IPC BX-59A Industrial Edge DeviceIndustrial Edge Virtual DeviceIndustrial Edge Device Kit - arm64 V1.20
CWE ID-CWE-1390
Weak Authentication
CVE-2024-52335
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.3||CRITICAL
EPSS-0.73% / 72.20%
||
7 Day CHG~0.00%
Published-06 Dec, 2024 | 13:14
Updated-06 Dec, 2024 | 17:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in syngo.plaza VB30E (All versions < VB30E_HF05). The affected application do not properly sanitize input data before sending it to the SQL server. This could allow an attacker with access to the application could use this vulnerability to execute malicious SQL commands to compromise the whole database.

Action-Not Available
Vendor-Siemens AG
Product-syngo.plaza VB30Esyngo_plaza_vb30e
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-27540
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.3||CRITICAL
EPSS-0.72% / 72.04%
||
7 Day CHG+0.36%
Published-16 Apr, 2025 | 17:37
Updated-19 Aug, 2025 | 14:49
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'Authenticate' method. This could allow an unauthenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25913)

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2024-49775
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.3||CRITICAL
EPSS-2.43% / 84.83%
||
7 Day CHG~0.00%
Published-16 Dec, 2024 | 15:06
Updated-13 Jan, 2026 | 10:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2501.0001), Opcenter Intelligence (All versions < V2501.0001), Opcenter Quality (All versions < V2512), Opcenter RDnL (All versions < V2410), SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions < V4.1 Update 3), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1), SINEC NMS (All versions if operated in conjunction with UMC < V2.15), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions). Affected products contain a heap-based buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to execute arbitrary code.

Action-Not Available
Vendor-Siemens AG
Product-Opcenter IntelligenceSIMATIC PCS neo V4.0SIMATIC PCS neo V5.0SINEC NMSTotally Integrated Automation Portal (TIA Portal) V18Totally Integrated Automation Portal (TIA Portal) V19Totally Integrated Automation Portal (TIA Portal) V16Opcenter Execution FoundationSIMATIC PCS neo V4.1Opcenter QualityTotally Integrated Automation Portal (TIA Portal) V17Opcenter RDnL
CWE ID-CWE-122
Heap-based Buffer Overflow
CVE-2025-26389
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-10||CRITICAL
EPSS-0.55% / 67.50%
||
7 Day CHG~0.00%
Published-13 May, 2025 | 09:38
Updated-06 Oct, 2025 | 10:34
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in OZW672 (All versions < V8.0), OZW772 (All versions < V8.0). The web service in affected devices does not sanitize the input parameters required for the `exportDiagramPage` endpoint. This could allow an unauthenticated remote attacker to execute arbitrary code with root privileges.

Action-Not Available
Vendor-Siemens AG
Product-ozw772ozw672ozw672_firmwareozw772_firmwareOZW772OZW672
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-7774
Matching Score-8
Assigner-Snyk
ShareView Details
Matching Score-8
Assigner-Snyk
CVSS Score-7.3||HIGH
EPSS-0.64% / 69.96%
||
7 Day CHG~0.00%
Published-17 Nov, 2020 | 12:30
Updated-16 Sep, 2024 | 20:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Prototype Pollution

The package y18n before 3.2.2, 4.0.1 and 5.0.5, is vulnerable to Prototype Pollution.

Action-Not Available
Vendor-y18n_projectn/aOracle CorporationSiemens AG
Product-y18nsinec_infrastructure_network_servicesgraalvmy18n
CWE ID-CWE-1321
Improperly Controlled Modification of Object Prototype Attributes ('Prototype Pollution')
CVE-2024-47901
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-10||CRITICAL
EPSS-2.78% / 85.74%
||
7 Day CHG~0.00%
Published-23 Oct, 2024 | 14:21
Updated-30 Oct, 2024 | 15:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in InterMesh 7177 Hybrid 2.0 Subscriber (All versions < V8.2.12), InterMesh 7707 Fire Subscriber (All versions < V7.2.12 only if the IP interface is enabled (which is not the default configuration)). The web server of affected devices does not sanitize the input parameters in specific GET requests that allow for code execution on operating system level. In combination with other vulnerabilities (CVE-2024-47902, CVE-2024-47903, CVE-2024-47904) this could allow an unauthenticated remote attacker to execute arbitrary code with root privileges.

Action-Not Available
Vendor-Siemens AG
Product-intermesh_7707_fire_subscriberintermesh_7177_hybrid_2.0_subscriberintermesh_7707_fire_subscriber_firmwareInterMesh 7707 Fire SubscriberInterMesh 7177 Hybrid 2.0 Subscriberintermesh_7177_hybrid2.0_subscriberintermesh_7707_fire_subscriber
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-47902
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-6.9||MEDIUM
EPSS-0.34% / 56.38%
||
7 Day CHG~0.00%
Published-23 Oct, 2024 | 14:21
Updated-30 Oct, 2024 | 15:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in InterMesh 7177 Hybrid 2.0 Subscriber (All versions < V8.2.12), InterMesh 7707 Fire Subscriber (All versions < V7.2.12 only if the IP interface is enabled (which is not the default configuration)). The web server of affected devices does not authenticate GET requests that execute specific commands (such as `ping`) on operating system level.

Action-Not Available
Vendor-Siemens AG
Product-intermesh_7707_fire_subscriberintermesh_7177_hybrid_2.0_subscriberintermesh_7707_fire_subscriber_firmwareInterMesh 7707 Fire SubscriberInterMesh 7177 Hybrid 2.0 Subscriberintermesh_7177_hybrid2.0_subscriberintermesh_7707_fire_subscriber
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-18316
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-1.71% / 82.01%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-05 Aug, 2024 | 01:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could gain remote code execution by sending specifically crafted packets to 1099/tcp. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sppa-t3000_application_serverSPPA-T3000 Application Server
CWE ID-CWE-502
Deserialization of Untrusted Data
CVE-2020-27304
Matching Score-8
Assigner-JFrog
ShareView Details
Matching Score-8
Assigner-JFrog
CVSS Score-9.8||CRITICAL
EPSS-1.00% / 76.54%
||
7 Day CHG~0.00%
Published-21 Oct, 2021 | 15:42
Updated-04 Aug, 2024 | 16:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The CivetWeb web library does not validate uploaded filepaths when running on an OS other than Windows, when using the built-in HTTP form-based file upload mechanism, via the mg_handle_form_request API. Web applications that use the file upload form handler, and use parts of the user-controlled filename in the output path, are susceptible to directory traversal

Action-Not Available
Vendor-civetweb_projectcivetweb_projectSiemens AG
Product-sinec_infrastructure_network_servicescivetwebcivetweb
CWE ID-CWE-23
Relative Path Traversal
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2020-24636
Matching Score-8
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-8
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-9.8||CRITICAL
EPSS-4.51% / 88.88%
||
7 Day CHG~0.00%
Published-29 Mar, 2021 | 19:08
Updated-04 Aug, 2024 | 15:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A remote execution of arbitrary commands vulnerability was discovered in some Aruba Instant Access Point (IAP) products in version(s): Aruba Instant 6.5.x: 6.5.4.17 and below; Aruba Instant 8.3.x: 8.3.0.13 and below; Aruba Instant 8.5.x: 8.5.0.10 and below; Aruba Instant 8.6.x: 8.6.0.5 and below; Aruba Instant 8.7.x: 8.7.0.0 and below. Aruba has released patches for Aruba Instant that address this security vulnerability.

Action-Not Available
Vendor-n/aSiemens AGAruba Networks
Product-scalance_w1750d_firmwareinstantscalance_w1750dAruba Instant Access Points
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-25226
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-0.68% / 71.18%
||
7 Day CHG~0.00%
Published-12 Jan, 2021 | 20:18
Updated-04 Aug, 2024 | 15:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0). The web server of the affected devices contains a vulnerability that may lead to a buffer overflow condition. An attacker could cause this condition on the webserver by sending a specially crafted request. The webserver could stop and not recover anymore.

Action-Not Available
Vendor-Siemens AG
Product-scalance_xc208scalance_xf206-1_firmwarescalance_xb205-3scalance_xc216eec_firmwarescalance_x320-1fe_firmwarescalance_xp208scalance_xc206-2sfp_g_\(e\/ip\)scalance_xc224-4c_g_eec_firmwarescalance_xc206-2sfp_g_eec_firmwarescalance_xp216scalance_xb213-3_firmwarescalance_x202-2irtscalance_xb205-3ldscalance_xc208g_eecscalance_xf204-2scalance_xc206-2sfp_g_firmwarescalance_xc216-4c_g_\(e\/ip\)_firmwarescalance_xb205-3_firmwarescalance_x308-2lh\+_firmwarescalance_x308-2ld_firmwarescalance_xb216_firmwarescalance_xp216poe_eec_firmwarescalance_xb213-3ldscalance_xf204-2ba_irtscalance_xc206-2g_poe__firmwarescalance_xf208_firmwarescalance_xc208g_eec_firmwarescalance_x204irt_firmwarescalance_xf204scalance_x308-2lh\+scalance_x202-2pirtscalance_xc208eec_firmwarescalance_xf204_dnascalance_xc208g_poescalance_x307-3_firmwarescalance_xc224-4c_g_\(e\/ip\)_firmwarescalance_xb213-3ld_firmwarescalance_x310fe_firmwarescalance_xf204-2ba_irt_firmwarescalance_x308-2ldscalance_xc216scalance_x308-2scalance_x200-4pirtscalance_xc206-2sfp_g_eecscalance_x201-3pirtscalance_xc206-2sfp_g_\(e\/ip\)_firmwarescalance_xp216eec_firmwarescalance_xc208g_\(e\/ip\)_firmwarescalance_xp208eecscalance_x202-2pirt_siplus_netscalance_xb208scalance_x308-2m_tsscalance_xc206-2g_poe_eecscalance_xc216-4c_g_firmwarescalance_xc206-2g_poe_scalance_x202-2irt_firmwarescalance_x307-3ldscalance_xc224__firmwarescalance_xf201-3p_irt_firmwarescalance_xc206-2sfp_gscalance_xp208poe_eecscalance_xf204-2ba_dnascalance_xc206-2_firmwarescalance_xb213-3scalance_x310fescalance_xc224-4c_g_scalance_xc216-4c_firmwarescalance_xp216poe_eecscalance_x308-2_firmwarescalance_xc216-4c_g_\(e\/ip\)scalance_x320-3ldfe_firmwarescalance_x307-3ld_firmwarescalance_x308-2lhscalance_x202-2pirt_firmwarescalance_x201-3pirt_firmwarescalance_x310scalance_xb205-3ld_firmwarescalance_xc224-4c_g_eecscalance_xc224_scalance_xp216_\(eip\)_firmwarescalance_xc216eecscalance_xf204_firmwarescalance_x308-2m_firmwarescalance_xp208_\(eip\)scalance_xc208gscalance_xb216scalance_xf204-2_firmwarescalance_xf202-2p_irtscalance_x308-2mscalance_xc206-2g_poe_eec_firmwarescalance_xc216_firmwarescalance_xc208eecscalance_xc206-2sfp_eec_firmwarescalance_xc216-4cscalance_x202-2pirt_siplus_net_firmwarescalance_xf204_dna_firmwarescalance_xc208g_firmwarescalance_xc206-2sfpscalance_xc208_firmwarescalance_x308-2m_ts_firmwarescalance_xp216_\(eip\)scalance_xf201-3p_irtscalance_xf208scalance_xp208_\(eip\)_firmwarescalance_xf204irtscalance_xp208eec_firmwarescalance_x204irtscalance_xc206-2sfp_firmwarescalance_xc208g_\(e\/ip\)scalance_xb208_firmwarescalance_xc224-4c_g__firmwarescalance_x308-2lh_firmwarescalance_xc206-2scalance_x320-3ldfescalance_xc208g_poe_firmwarescalance_xf206-1scalance_x310_firmwarescalance_x200-4pirt_firmwarescalance_xf204-2ba_dna_firmwarescalance_xc224-4c_g_\(e\/ip\)scalance_x320-1fescalance_xc216-4c_g_eec_firmwarescalance_xf202-2p_irt_firmwarescalance_xp216_firmwarescalance_x307-3scalance_xp208_firmwarescalance_xp208poe_eec_firmwarescalance_xp216eecscalance_xf204irt_firmwarescalance_xc216-4c_g_eecscalance_xc206-2sfp_eecscalance_xc216-4c_gSCALANCE X-200 switch family (incl. SIPLUS NET variants)SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)
CWE ID-CWE-122
Heap-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2020-25228
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-0.45% / 62.91%
||
7 Day CHG~0.00%
Published-14 Dec, 2020 | 21:05
Updated-04 Aug, 2024 | 15:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). A service available on port 10005/tcp of the affected devices could allow complete access to all services without authorization. An attacker could gain full control over an affected device, if he has access to this service. The system manual recommends to protect access to this port.

Action-Not Available
Vendor-Siemens AG
Product-logo\!_8_bmlogo\!_8_bm_firmwareLOGO! 8 BM (incl. SIPLUS variants)
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2002-1484
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-7.41% / 91.55%
||
7 Day CHG~0.00%
Published-18 Mar, 2003 | 05:00
Updated-03 Apr, 2025 | 01:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

DB4Web server, when configured to use verbose debug messages, allows remote attackers to use DB4Web as a proxy and attempt TCP connections to other systems (port scan) via a request for a URL that specifies the target IP address and port, which produces a connection status in the resulting error message.

Action-Not Available
Vendor-n/aSiemens AG
Product-db4webn/a
CWE ID-CWE-918
Server-Side Request Forgery (SSRF)
CVE-2012-3020
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.5||HIGH
EPSS-0.44% / 62.73%
||
7 Day CHG~0.00%
Published-06 Aug, 2012 | 16:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The Siemens Synco OZW Web Server devices OZW672.*, OZW772.*, and OZW775 with firmware before 4 have an unspecified default password, which makes it easier for remote attackers to obtain administrative access via a network session.

Action-Not Available
Vendor-n/aSiemens AG
Product-synco_ozw_web_serversynco_ozw_web_server_firmwaren/a
CVE-2012-3032
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.5||HIGH
EPSS-0.54% / 67.01%
||
7 Day CHG~0.00%
Published-18 Sep, 2012 | 14:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

SQL injection vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to execute arbitrary SQL commands via a crafted SOAP message.

Action-Not Available
Vendor-n/aSiemens AG
Product-winccsimatic_pcs7n/a
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2019-13918
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-0.48% / 64.49%
||
7 Day CHG~0.00%
Published-13 Sep, 2019 | 16:38
Updated-05 Aug, 2024 | 00:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0 SP1). The web interface has no means to prevent password guessing attacks. The vulnerability could be exploited by an attacker with network access to the vulnerable software, requiring no privileges and no user interaction. The vulnerability could allow full access to the web interface. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sinema_remote_connect_serverSINEMA Remote Connect Server
CWE ID-CWE-307
Improper Restriction of Excessive Authentication Attempts
CWE ID-CWE-521
Weak Password Requirements
CVE-2023-51438
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-10||CRITICAL
EPSS-0.45% / 63.09%
||
7 Day CHG~0.00%
Published-09 Jan, 2024 | 10:00
Updated-22 May, 2025 | 17:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC IPC1047E (All versions with maxView Storage Manager < V4.14.00.26068 on Windows), SIMATIC IPC647E (All versions with maxView Storage Manager < V4.14.00.26068 on Windows), SIMATIC IPC847E (All versions with maxView Storage Manager < V4.14.00.26068 on Windows). In default installations of maxView Storage Manager where Redfish® server is configured for remote system management, a vulnerability has been identified that can provide unauthorized access.

Action-Not Available
Vendor-microchipSiemens AG
Product-simatic_ipc647esimatic_ipc847emaxview_storage_managersimatic_ipc1047eSIMATIC IPC847ESIMATIC IPC1047ESIMATIC IPC647E
CWE ID-CWE-20
Improper Input Validation
CVE-2019-12262
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.16% / 37.25%
||
7 Day CHG~0.00%
Published-14 Aug, 2019 | 19:18
Updated-04 Aug, 2024 | 23:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Wind River VxWorks 6.6, 6.7, 6.8, 6.9 and 7 has Incorrect Access Control in the RARP client component. IPNET security vulnerability: Handling of unsolicited Reverse ARP replies (Logical Flaw).

Action-Not Available
Vendor-windriverbeldenn/aSiemens AG
Product-hirschmann_rsp20ruggedcom_win7025_firmwarehirschmann_ees25hirschmann_grs1142hirschmann_grs1030ruggedcom_win7018_firmwarehirschmann_rspe32hirschmann_grs1130garrettcom_magnum_dx940ehirschmann_rspe35hirschmann_eesx20hirschmann_rspe37ruggedcom_win7018hirschmann_grs1042hirschmann_rsp35ruggedcom_win7000ruggedcom_win7200garrettcom_magnum_dx940e_firmwarevxworkshirschmann_msp40hirschmann_octopus_os3hirschmann_rsp30hirschmann_dragon_mach4000hirschmann_dragon_mach4500hirschmann_msp32hirschmann_rsp25hirschmann_rail_switch_power_smarthirschmann_grs1020hirschmann_eesx30hirschmann_rail_switch_power_litehirschmann_eagle20hirschmann_eagle30hirschmann_hiosruggedcom_win7025hirschmann_rspe30hirschmann_eagle_oneruggedcom_win7200_firmwarehirschmann_ees20hirschmann_red25ruggedcom_win7000_firmwarehirschmann_msp30hirschmann_grs1120n/a
CVE-2019-13933
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.6||HIGH
EPSS-0.71% / 71.80%
||
7 Day CHG~0.00%
Published-16 Jan, 2020 | 00:00
Updated-05 Aug, 2024 | 00:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SCALANCE X204RNA (HSR), SCALANCE X204RNA (PRP), SCALANCE X204RNA EEC (HSR), SCALANCE X204RNA EEC (PRP), SCALANCE X204RNA EEC (PRP/HSR), SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices contain a vulnerability that allows an unauthenticated attacker to violate access-control rules. The vulnerability can be triggered by sending GET request to specific uniform resource locator on the web configuration interface of the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. An attacker could use the vulnerability to obtain sensitive information or change the device configuration. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-scalance_x408-2_firmwarescalance_x-200rnascalance_xr-300scalance_x204rna_firmwarescalance_x-300scalance_x-200rna_firmwarescalance_x-300_firmwarescalance_x408-2scalance_xr-300_firmwarescalance_x204rnasiplus_net_csm_1277_firmwarescalance_xr-300wg_firmwarescalance_xr-300wgsiplus_net_csm_1277SCALANCE XR324-12M TS (24V)SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)SCALANCE XR324-4M PoE (24V, ports on rear)SCALANCE XR324-4M EEC (24V, ports on front)SCALANCE XR324-12M (230V, ports on rear)SCALANCE X307-2 EEC (2x 24V, coated)SCALANCE XR324-4M PoE TS (24V, ports on front)SCALANCE X307-3SCALANCE X308-2MSCALANCE XR324-12M (24V, ports on rear)SCALANCE X308-2SCALANCE X308-2M PoESCALANCE X310FESCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)SCALANCE X308-2LH+SCALANCE X302-7 EEC (24V, coated)SCALANCE X307-2 EEC (230V, coated)SCALANCE X204RNA EEC (PRP)SCALANCE X307-3LDSCALANCE X308-2LHSCALANCE XR324-4M EEC (24V, ports on rear)SCALANCE X204RNA (PRP)SCALANCE XR324-4M PoE (24V, ports on front)SCALANCE X302-7 EEC (2x 230V)SCALANCE X408-2SIPLUS NET SCALANCE X308-2SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)SCALANCE XR324-4M PoE (230V, ports on rear)SCALANCE X302-7 EEC (230V)SCALANCE X307-2 EEC (24V, coated)SCALANCE X307-2 EEC (2x 230V, coated)SCALANCE X302-7 EEC (2x 24V, coated)SCALANCE X308-2LDSCALANCE X307-2 EEC (24V)SCALANCE X204RNA EEC (HSR)SCALANCE X304-2FESCALANCE X310SCALANCE X307-2 EEC (2x 24V)SCALANCE X307-2 EEC (230V)SCALANCE X204RNA (HSR)SCALANCE XR324-12M (24V, ports on front)SCALANCE X320-1 FESCALANCE X302-7 EEC (2x 24V)SCALANCE X306-1LD FESCALANCE X308-2M TSSCALANCE XR324-4M PoE (230V, ports on front)SCALANCE X307-2 EEC (2x 230V)SCALANCE X302-7 EEC (230V, coated)SCALANCE X302-7 EEC (24V)SCALANCE X302-7 EEC (2x 230V, coated)SCALANCE X320-1-2LD FESCALANCE X204RNA EEC (PRP/HSR)SCALANCE XR324-4M EEC (2x 24V, ports on rear)SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)SCALANCE XR324-12M (230V, ports on front)SCALANCE XR324-4M EEC (2x 24V, ports on front)
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-10939
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-0.44% / 62.89%
||
7 Day CHG~0.00%
Published-14 Apr, 2020 | 19:50
Updated-04 Aug, 2024 | 22:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TIM 3V-IE (incl. SIPLUS NET variants) (All versions < V2.8), TIM 3V-IE Advanced (incl. SIPLUS NET variants) (All versions < V2.8), TIM 3V-IE DNP3 (incl. SIPLUS NET variants) (All versions < V3.3), TIM 4R-IE (incl. SIPLUS NET variants) (All versions < V2.8), TIM 4R-IE DNP3 (incl. SIPLUS NET variants) (All versions < V3.3). The affected versions contain an open debug port that is available under certain specific conditions. The vulnerability is only available if the IP address is configured to 192.168.1.2. If available, the debug port could be exploited by an attacker with network access to the device. No user interaction is required to exploit this vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the affected device. At the stage of publishing this security advisory no public exploitation is known.

Action-Not Available
Vendor-Siemens AG
Product-tim_4r-ie_dnp3tim_4r-ietim_4r-ie_firmwaretim_3v-ie_dnp3_firmwaretim_3v-ie_advancedtim_3v-ie_advanced_firmwaretim_3v-ie_firmwaretim_3v-ietim_3v-ie_dnp3tim_4r-ie_dnp3_firmwareTIM 3V-IE DNP3 (incl. SIPLUS NET variants)TIM 4R-IE (incl. SIPLUS NET variants)TIM 4R-IE DNP3 (incl. SIPLUS NET variants)TIM 3V-IE (incl. SIPLUS NET variants)TIM 3V-IE Advanced (incl. SIPLUS NET variants)
CWE ID-CWE-489
Active Debug Code
CVE-2019-10919
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.4||CRITICAL
EPSS-0.63% / 69.79%
||
7 Day CHG~0.00%
Published-14 May, 2019 | 19:54
Updated-04 Aug, 2024 | 22:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Attackers with access to port 10005/tcp could perform device reconfigurations and obtain project files from the devices. The system manual recommends to protect access to this port. The security vulnerability could be exploited by an unauthenticated attacker with network access to port 10005/tcp. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-logo\!8_bm_firmwarelogo\!8_bmLOGO! 8 BM (incl. SIPLUS variants)
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-8274
Matching Score-8
Assigner-Kaspersky
ShareView Details
Matching Score-8
Assigner-Kaspersky
CVSS Score-9.8||CRITICAL
EPSS-4.00% / 88.16%
||
7 Day CHG-0.51%
Published-09 Mar, 2019 | 00:00
Updated-16 Sep, 2024 | 19:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

UltraVNC revision 1211 has a heap buffer overflow vulnerability in VNC server code inside file transfer offer handler, which can potentially in result code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212.

Action-Not Available
Vendor-uvncSiemens AGKaspersky Lab
Product-sinumerik_pcu_base_win10_software\/ipcultravncsinumerik_pcu_base_win7_software\/ipcsinumerik_access_mymachine\/p2pUltraVNC
CWE ID-CWE-122
Heap-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
  • Previous
  • 1
  • 2
  • 3
  • ...
  • 25
  • 26
  • Next
Details not found