A vulnerability has been identified in Desigo PXM30-1 (All versions < V02.20.126.11-41), Desigo PXM30.E (All versions < V02.20.126.11-41), Desigo PXM40-1 (All versions < V02.20.126.11-41), Desigo PXM40.E (All versions < V02.20.126.11-41), Desigo PXM50-1 (All versions < V02.20.126.11-41), Desigo PXM50.E (All versions < V02.20.126.11-41), PXG3.W100-1 (All versions < V02.20.126.11-37), PXG3.W100-2 (All versions < V02.20.126.11-41), PXG3.W200-1 (All versions < V02.20.126.11-37), PXG3.W200-2 (All versions < V02.20.126.11-41). Endpoints of the “Operation” web application that interpret and execute Axon language queries allow file read access to the device file system with root privileges. By supplying specific I/O related Axon queries, a remote low-privileged attacker can read sensitive files on the device.
A vulnerability has been identified in Simcenter STAR-CCM+ (All versions only if the Power-on-Demand public license server is used). Affected applications expose user, host and display name of users, when the public license server is used. This could allow an attacker to retrieve this information.
A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V3.0). The affected application exposes an internal service port to be accessible from outside the system. This could allow an unauthorized attacker to access the application.
The Siemens SPCanywhere application for Android and iOS does not use encryption during lookups of system ID to IP address mappings, which allows man-in-the-middle attackers to discover alarm IP addresses and spoof servers by intercepting the client-server data stream.
The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to read arbitrary files via crafted packets.
A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.31), Mendix Applications using Mendix 8 (All versions < V8.18.18), Mendix Applications using Mendix 9 (All versions < V9.11), Mendix Applications using Mendix 9 (V9.6) (All versions < V9.6.12). Applications built with an affected system publicly expose the internal project structure. This could allow an unauthenticated remote attacker to read confidential information.
A vulnerability has been identified in SCALANCE M875 (All versions). An authenticated remote attacker with access to the web interface (443/tcp), could potentially read and download arbitrary files from the device's file system. Successful exploitation requires that the attacker has network access to the web interface. The attacker must be authenticated as administrative user to exploit the security vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote attackers to obtain sensitive information via an HTTP request.
A vulnerability has been identified in Teamcenter Active Workspace V4 (All versions < V4.3.9), Teamcenter Active Workspace V5.0 (All versions < V5.0.7), Teamcenter Active Workspace V5.1 (All versions < V5.1.4). By sending malformed requests, a remote attacker could leak an application token due to an error not properly handled by the system.
A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). An authenticated attacker could download the user profile of any user. With this, the attacker could leak confidential information of any user in the affected system.
Siemens RUGGEDCOM ROX I (all versions) contain a vulnerability that could allow an authenticated user to read arbitrary files through the web interface at port 10000/TCP and access sensitive information.
A vulnerability has been identified in Desigo Insight (All versions). Some error messages in the web application show the absolute path to the requested resource. This could allow an authenticated attacker to retrieve additional information about the host system.
A vulnerability has been identified in Spectrum Power 4 (All versions < V4.70 SP8). If configured in an insecure manner, the web server might be susceptible to a directory listing attack.
WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to discover a username and password via crafted parameters to unspecified methods in ActiveX controls.
node-fetch is vulnerable to Exposure of Sensitive Information to an Unauthorized Actor
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The affected device offered SNMP read and write capacities with a publicly know hardcoded community string. The security vulnerability could be exploited by an attacker with network access to the affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SINAMICS PERFECT HARMONY GH180 with NXG I control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- (All Versions with option G21, G22, G23, G26, G28, G31, G32, G38, G43 or G46), SINAMICS PERFECT HARMONY GH180 with NXG II control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- (All Versions with option G21, G22, G23, G26, G28, G31, G32, G38, G43 or G46). An improperly configured Parameter Read/Write execution via Field bus network may cause the controller to restart. The vulnerability could be exploited by an attacker with network access to the device. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise the availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.
The Siemens SIMATIC WinCC Sm@rtClient and Sm@rtClient Lite applications before 01.00.01.00 for Android do not properly store passwords, which allows physically proximate attackers to obtain sensitive information via unspecified vectors.
Siemens Ruggedcom WIN51xx devices with firmware before SS4.4.4624.35, WIN52xx devices with firmware before SS4.4.4624.35, WIN70xx devices with firmware before BS4.4.4621.32, and WIN72xx devices with firmware before BS4.4.4621.32 allow context-dependent attackers to discover password hashes by reading (1) files or (2) security logs.
Siemens SIMATIC STEP 7 (TIA Portal) 12 and 13 before 13 SP1 Upd1 improperly stores password data within project files, which makes it easier for local users to determine cleartext (1) protection-level passwords or (2) web-server passwords by leveraging the ability to read these files.
curl 7.1.1 to and including 7.75.0 is vulnerable to an "Exposure of Private Personal Information to an Unauthorized Actor" by leaking credentials in the HTTP Referer: header. libcurl does not strip off user credentials from the URL when automatically populating the Referer: HTTP request header field in outgoing HTTP requests, and therefore risks leaking sensitive data to the server that is the target of the second HTTP request.
curl supports the `-t` command line option, known as `CURLOPT_TELNETOPTIONS`in libcurl. This rarely used option is used to send variable=content pairs toTELNET servers.Due to flaw in the option parser for sending `NEW_ENV` variables, libcurlcould be made to pass on uninitialized data from a stack based buffer to theserver. Therefore potentially revealing sensitive internal information to theserver using a clear-text network protocol.This could happen because curl did not call and use sscanf() correctly whenparsing the string provided by the application.
Siemens SINUMERIK Integrate Operate Clients between 2.0.3.00.016 (including) and 2.0.6 (excluding) and between 3.0.4.00.032 (including) and 3.0.6 (excluding) contain a vulnerability that could allow an attacker to read and manipulate data in TLS sessions while performing a man-in-the-middle (MITM) attack.
A vulnerability has been identified in SIMATIC Reader RF610R CMIIT (6GT2811-6BC10-2AA0) (All versions < V4.2), SIMATIC Reader RF610R ETSI (6GT2811-6BC10-0AA0) (All versions < V4.2), SIMATIC Reader RF610R FCC (6GT2811-6BC10-1AA0) (All versions < V4.2), SIMATIC Reader RF615R CMIIT (6GT2811-6CC10-2AA0) (All versions < V4.2), SIMATIC Reader RF615R ETSI (6GT2811-6CC10-0AA0) (All versions < V4.2), SIMATIC Reader RF615R FCC (6GT2811-6CC10-1AA0) (All versions < V4.2), SIMATIC Reader RF650R ARIB (6GT2811-6AB20-4AA0) (All versions < V4.2), SIMATIC Reader RF650R CMIIT (6GT2811-6AB20-2AA0) (All versions < V4.2), SIMATIC Reader RF650R ETSI (6GT2811-6AB20-0AA0) (All versions < V4.2), SIMATIC Reader RF650R FCC (6GT2811-6AB20-1AA0) (All versions < V4.2), SIMATIC Reader RF680R ARIB (6GT2811-6AA10-4AA0) (All versions < V4.2), SIMATIC Reader RF680R CMIIT (6GT2811-6AA10-2AA0) (All versions < V4.2), SIMATIC Reader RF680R ETSI (6GT2811-6AA10-0AA0) (All versions < V4.2), SIMATIC Reader RF680R FCC (6GT2811-6AA10-1AA0) (All versions < V4.2), SIMATIC Reader RF685R ARIB (6GT2811-6CA10-4AA0) (All versions < V4.2), SIMATIC Reader RF685R CMIIT (6GT2811-6CA10-2AA0) (All versions < V4.2), SIMATIC Reader RF685R ETSI (6GT2811-6CA10-0AA0) (All versions < V4.2), SIMATIC Reader RF685R FCC (6GT2811-6CA10-1AA0) (All versions < V4.2), SIMATIC RF1140R (6GT2831-6CB00) (All versions < V1.1), SIMATIC RF1170R (6GT2831-6BB00) (All versions < V1.1), SIMATIC RF166C (6GT2002-0EE20) (All versions < V2.2), SIMATIC RF185C (6GT2002-0JE10) (All versions < V2.2), SIMATIC RF186C (6GT2002-0JE20) (All versions < V2.2), SIMATIC RF186CI (6GT2002-0JE50) (All versions < V2.2), SIMATIC RF188C (6GT2002-0JE40) (All versions < V2.2), SIMATIC RF188CI (6GT2002-0JE60) (All versions < V2.2), SIMATIC RF360R (6GT2801-5BA30) (All versions < V2.2). The service log files of the affected application can be accessed without proper authentication. This could allow an unauthenticated attacker to get access to sensitive information.
A vulnerability has been identified in SIMATIC CP 343-1 Advanced (incl. SIPLUS NET variant) (All versions < V3.0.53), SIMATIC CP 443-1 Advanced (incl. SIPLUS NET variant) (All versions < V3.2.17), SIMATIC S7-300 PN/DP CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP CPU family (incl. SIPLUS variants) (All versions). The integrated web server delivers cookies without the "secure" flag. Modern browsers interpreting the flag would mitigate potential data leakage in case of clear text transmission.
The Comcast firmware on Cisco DPC3939 (firmware version dpc3939-P20-18-v303r20421733-160420a-CMCST) and DPC3939 (firmware version dpc3939-P20-18-v303r20421746-170221a-CMCST) devices allows remote attackers to discover the CM MAC address by connecting to the device's xfinitywifi hotspot.
An exposure of sensitive information to an unauthorized actor vulnerability [CWE-200] in FortiClientEMS versions 7.0.0 through 7.0.4, 7.0.6 through 7.0.7, in all 6.4 and 6.2 version management interface may allow an unauthenticated attacker to gain information on environment variables such as the EMS installation path.
Certain NETGEAR devices are affected by an attacker's ability to read arbitrary files. This affects DST6501 before 1.1.0.6 and WNR2000v2 before 1.2.0.8.
Certain NETGEAR devices are affected by an attacker's ability to read arbitrary files. This affects D7800 before 1.0.1.28, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.20, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR4300v2 before 1.0.0.48, and WNDR4500v3 before 1.0.0.48.
Certain NETGEAR devices are affected by an attacker's ability to read arbitrary files. This affects D6220 before 1.0.0.32, D6400 before 1.0.0.60, D8500 before 1.0.3.29, R6250 before 1.0.4.16, R6300v2 before 1.0.4.18, R6400 before 1.01.32, R6400v2 before 1.0.2.44, R6700 before 1.0.1.36, R6900 before 1.0.1.34, R7000 before 1.0.9.14, R7000P before 1.3.0.8, R6900P before 1.3.0.8, R7100LG before 1.0.0.34, R7300DST before 1.0.0.56, R7900 before 1.0.1.26, R8000 before 1.0.4.4, R8500 before 1.0.2.106, R8300 before 1.0.2.106, and WNDR3400v3 before 1.0.1.16.
An exposure of sensitive information to an unauthorized actor vulnerability [CWE-200] in FortiClient for Linux version 7.0.2 and below, 6.4.7 and below and 6.2.9 and below may allow an unauthenticated attacker to access the confighandler webserver via external binaries.
Syska Smart Bulb devices through 2017-08-06 receive RGB parameters over cleartext Bluetooth Low Energy (BLE), leading to sniffing, reverse engineering, and replay attacks.
The TrackR Bravo mobile app stores the account password used to authenticate to the cloud API in cleartext in the cache.db file. Updated apps, version 5.1.6 for iOS and 2.2.5 for Android, have been released by the vendor to address the vulnerabilities in CVE-2016-6538, CVE-2016-6539, CVE-2016-6540 and CVE-2016-6541.
IBM Security Verify Privilege On-Premises 11.5 could allow a user to obtain version number information using a specially crafted HTTP request that could be used in further attacks against the system. IBM X-Force ID: 207899.
The D-Link DCS-932L camera with firmware 1.02 allows remote attackers to discover the password via a UDP broadcast packet, as demonstrated by running the D-Link Setup Wizard and reading the _paramR["P"] value.
The DNAv4 protocol implementation in the DHCP component in Apple iOS before 6 sends Wi-Fi packets containing a MAC address of a host on a previously used network, which might allow remote attackers to obtain sensitive information about previous device locations by sniffing an unencrypted Wi-Fi network for these packets.
Brocade SANnav before v2.3.0a lacks protection mechanisms on port 2377/TCP and 7946/TCP, which could allow an unauthenticated attacker to sniff the SANnav Docker information.
Centreon before 19.10.7 exposes Session IDs in server responses.
Improper Access Control vulnerability in web service of Secomea SiteManager allows local attacker without credentials to gather network information and configuration of the SiteManager. This issue affects: Secomea SiteManager All versions prior to 9.5 on Hardware.
Padding bytes in Ethernet packets on PA-200, PA-220, PA-500, PA-800, PA-2000 Series, PA-3000 Series, PA-3200 Series, PA-5200 Series, and PA-7000 Series firewalls are not cleared before the data frame is created. This leaks a small amount of random information from the firewall memory into the Ethernet packets. An attacker on the same Ethernet subnet as the PAN-OS firewall is able to collect potentially sensitive information from these packets. This issue is also known as Etherleak and is detected by security scanners as CVE-2003-0001. This issue impacts: PAN-OS 8.1 version earlier than PAN-OS 8.1.18; PAN-OS 9.0 versions earlier than PAN-OS 9.0.12; PAN-OS 9.1 versions earlier than PAN-OS 9.1.5.
A information disclosure vulnerability in the Android system (bluetooth). Product: Android. Versions: 5.1.1, 6.0, 6.0.1, 7.0, 7.1.1, 7.1.2, 8.0, 8.1. Android ID: A-67058064.
A information disclosure vulnerability in the Android system (bluetooth). Product: Android. Versions: 5.1.1, 6.0, 6.0.1, 7.0, 7.1.1, 7.1.2, 8.0, 8.1. Android ID: A-68818034.
A vulnerability in the packet processing code of Cisco IOS Software for Cisco Aironet Access Points could allow an unauthenticated, adjacent attacker to retrieve content from memory on an affected device, which could lead to the disclosure of confidential information. The vulnerability is due to insufficient condition checks that are performed by the affected device when the device adds padding to egress packets. An attacker could exploit this vulnerability by sending a crafted IP packet to an affected device. A successful exploit could allow the attacker to retrieve content from memory on the affected device, which could lead to the disclosure of confidential information. Cisco Bug IDs: CSCvc21581.
A vulnerability was found in Linksys WRT54GL 4.30.18. It has been classified as problematic. This affects an unknown part of the file /wlaninfo.htm of the component Web Management Interface. The manipulation leads to information disclosure. The exploit has been disclosed to the public and may be used. The identifier VDB-253329 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Linksys WRT54GL 4.30.18 and classified as problematic. Affected by this issue is some unknown functionality of the file /SysInfo.htm of the component Web Management Interface. The manipulation leads to information disclosure. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-253328. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Netgear R7000 1.0.11.136_10.2.120 and classified as problematic. Affected by this issue is some unknown functionality of the file /debuginfo.htm of the component Web Management Interface. The manipulation leads to information disclosure. The exploit has been disclosed to the public and may be used. VDB-253382 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Linksys WRT54GL 4.30.18. It has been declared as problematic. This vulnerability affects unknown code of the file /SysInfo1.htm of the component Web Management Interface. The manipulation leads to information disclosure. The exploit has been disclosed to the public and may be used. VDB-253330 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Rebuild up to 3.5.5 and classified as problematic. This issue affects the function QiniuCloud.getStorageFile of the file /filex/proxy-download. The manipulation of the argument url leads to information disclosure. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-252455.
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists in Modicon M221 (all references, all versions) that could allow non sensitive information disclosure when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller.
A vulnerability was found in Hikvision Intercom Broadcasting System 3.0.3_20201113_RELEASE(HIK). It has been classified as problematic. This affects an unknown part of the file access/html/system.html of the component Log File Handler. The manipulation leads to information disclosure. The exploit has been disclosed to the public and may be used. Upgrading to version 4.1.0 is able to address this issue. It is recommended to upgrade the affected component. The identifier VDB-248253 was assigned to this vulnerability.