An issue was discovered in ONAP SDC through Dublin. By accessing port 6000 of demo-sdc-sdc-fe pod, an unauthenticated attacker (who already has access to pod-to-pod communication) may execute arbitrary code inside that pod. All ONAP Operations Manager (OOM) setups are affected.
In ONAP MSB through Dublin, by accessing an applicable port (30234, 30290, 32010, 30270, 30224, 30281, 30254, 30285, and/or 30271), an attacker gains full access to the respective ONAP services without any authentication. All ONAP Operations Manager (OOM) setups are affected.
An issue was discovered in upgrade_htmls.cgi on VStarcam 100T (C7824WIP) KR75.8.53.20 and 200V (C38S) KR203.18.1.20 devices. The web service, network, and account files can be manipulated through a web UI firmware update without any authentication. The attacker can achieve access to the device through a manipulated web UI firmware update.
Password recovery vulnerability in SICK SIM1000 FX Partnumber 1097816 and 1097817 with firmware version <1.6.0 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The recommended solution is to update the firmware to a version >= 1.6.0 as soon as possible (available in SICK Support Portal).
An issue was discovered in ONAP SDC through Dublin. By accessing port 4000 of demo-sdc-sdc-be pod, an unauthenticated attacker (who already has access to pod-to-pod communication) may execute arbitrary code inside that pod. All ONAP Operations Manager (OOM) setups are affected.
In ONAP CLI through Dublin, by accessing an applicable port (30234, 30290, 32010, 30270, 30224, 30281, 30254, 30285, and/or 30271), an attacker gains full access to the respective ONAP services without any authentication. All ONAP Operations Manager (OOM) setups are affected.
An issue was discovered on D-Link DIR-600M 3.02, 3.03, 3.04, and 3.06 devices. wan.htm can be accessed directly without authentication, which can lead to disclosure of information about the WAN, and can also be leveraged by an attacker to modify the data fields of the page.
An issue was discovered in ONAP HOLMES before Dublin. By accessing port 9202 of dep-holmes-engine-mgmt pod, an unauthenticated attacker (who already has access to pod-to-pod communication) may execute arbitrary code inside that pod. All ONAP Operations Manager (OOM) setups are affected.
In ONAP Logging through Dublin, by accessing an applicable port (30234, 30290, 32010, 30270, 30224, 30281, 30254, 30285, and/or 30271), an attacker gains full access to the respective ONAP services without any authentication. All ONAP Operations Manager (OOM) setups are affected.
An issue was discovered in ONAP SDC through Dublin. By accessing port 7000 of demo-sdc-sdc-wfd-fe pod, an unauthenticated attacker (who already has access to pod-to-pod communication) may execute arbitrary code inside that pod. All ONAP Operations Manager (OOM) setups are affected.
RedwoodHQ 2.5.5 does not require any authentication for database operations, which allows remote attackers to create admin users via a con.automationframework users insert_one call.
An issue was discovered in ONAP SDC through Dublin. By accessing port 4001 of demo-sdc-sdc-onboarding-be pod, an unauthenticated attacker (who already has access to pod-to-pod communication) may execute arbitrary code inside that pod. All ONAP Operations Manager (OOM) setups are affected.
HCL OneTest UI V9.5, V10.0, and V10.1 does not perform authentication for functionality that either requires a provable user identity or consumes a significant amount of resources.
Improper Access Control in the RCP+ server of the Bosch Video Recording Manager (VRM) component allows arbitrary and unauthenticated access to a limited subset of certificates, stored in the underlying Microsoft Windows operating system. The fixed versions implement modified authentication checks. Prior releases of VRM software version 3.70 are considered unaffected. This vulnerability affects VRM v3.70.x, v3.71 < v3.71.0034 and v3.81 < 3.81.0050; DIVAR IP 5000 3.80 < 3.80.0039; BVMS all versions using VRM.
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 and newer (All versions), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 and newer (All versions). An attacker with network access to affected installations, which are configured without "Encrypted Communication", can execute arbitrary code. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected installation. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.
Password recovery vulnerability in SICK SIM1004 Partnumber 1098148 with firmware version <2.0.0 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The recommended solution is to update the firmware to a version >= 2.0.0 as soon as possible (available in SICK Support Portal).
Password recovery vulnerability in SICK SIM4000 (PPC) Partnumber 1078787 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The firmware versions <=1.10.1 allow to optionally disable device configuration over the network interfaces. Please make sure that you apply general security practices when operating the SIM4000. A fix is planned but not yet scheduled.
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Attackers with access to port 10005/tcp could perform device reconfigurations and obtain project files from the devices. The system manual recommends to protect access to this port. The security vulnerability could be exploited by an unauthenticated attacker with network access to port 10005/tcp. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability was found in SourceCodester Company Website CMS 1.0. It has been declared as critical. Affected by this vulnerability is an unknown functionality of the file /dashboard/settings. The manipulation leads to improper authentication. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-206161 was assigned to this vulnerability.
A vulnerability, which was classified as critical, was found in MAXTECH MAX-G866ac 0.4.1_TBRO_20160314. This affects an unknown part of the component Remote Management. The manipulation leads to missing authentication. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-227001 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Password recovery vulnerability in SICK SIM2000ST Partnumber 1080579 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The firmware versions <=1.7.0 allow to optionally disable device configuration over the network interfaces. Please make sure that you apply general security practices when operating the SIM2000ST. A fix is planned but not yet scheduled.
vBulletin before 5.5.6pl1, 5.6.0 before 5.6.0pl1, and 5.6.1 before 5.6.1pl1 has incorrect access control.
Arbitrary code execution vulnerability on Micro Focus Operation Bridge Reporter, affecting version 10.40 and earlier. The vulnerability could allow remote attackers to execute arbitrary code on affected installations of OBR.
A file write vulnerability exists in the OAS Engine SecureTransferFiles functionality of Open Automation Software OAS Platform V16.00.0112. A specially-crafted series of network requests can lead to remote code execution. An attacker can send a sequence of requests to trigger this vulnerability.
An authentication bypass vulnerability exists which allows an unauthenticated attacker to control administrator backup functions, leading to compromise of passwords, secrets, and application session tokens stored by the Unified PAM.
Veeam Backup & Replication 10.x and 11.x has Incorrect Access Control (issue 1 of 2).
The TP-240 (aka tp240dvr) component in Mitel MiCollab before 9.4 SP1 FP1 and MiVoice Business Express through 8.1 allows remote attackers to obtain sensitive information and cause a denial of service (performance degradation and excessive outbound traffic). This was exploited in the wild in February and March 2022 for the TP240PhoneHome DDoS attack.
Anviz Global M3 Outdoor RFID Access Control executes any command received from any source. No authentication/encryption is done. Attackers can fully interact with the device: for example, send the "open door" command, download the users list (which includes RFID codes and passcodes in cleartext), or update/create users. The same attack can be executed on a local network and over the internet (if the device is exposed on a public IP address).
WebAccess/NMS (versions prior to 3.0.2) allows an unauthenticated remote user to create a new admin account.
Fujifilm FCR Capsula X/ Carbon X/ FCR XC-2, model versions CR-IR 357 FCR Carbon X, CR-IR 357 FCR XC-2, FCR-IR 357 FCR Capsula X provide insecure telnet services that lack authentication requirements. An attacker who successfully exploits this vulnerability may be able to access the underlying operating system.
In IOBit IOTransfer 4.3.1.1561, an unauthenticated attacker can send GET and POST requests to Airserv and gain arbitrary read/write access to the entire file-system (with admin privileges) on the victim's endpoint, which can result in data theft and remote code execution.
When connecting to a certain port Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) may allow an attacker to send certain XML messages to a specific port without proper authentication. Successful exploitation of this vulnerability could allow a remote unauthenticated attacker to read and modify the affected product’s configuration.
SAUTER Controls Nova 200–220 Series with firmware version 3.3-006 and prior and BACnetstac version 4.2.1 and prior allows the execution of commands without credentials. As Telnet and file transfer protocol (FTP) are the only protocols available for device management, an unauthorized user could access the system and modify the device configuration, which could result in the unauthorized user executing unrestricted malicious commands.
TerraMaster NAS 4.2.29 and earlier allows remote attackers to discover the administrative password by sending "User-Agent: TNAS" to module/api.php?mobile/webNasIPS and then reading the PWD field in the response.
Authentication is currently unsupported in Haas Controller version 100.20.000.1110 when using the “Ethernet Q Commands” service, which allows any user on the same network segment as the controller (even while connected remotely) to access the service and write unauthorized macros to the device.
Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) may allow an attacker to send certain commands to a specific port without authentication. Successful exploitation of this vulnerability could allow a remote unauthenticated attacker to obtain full file-system access and remote code execution.
eQ-3 HomeMatic CCU2 devices before 2.41.8 and CCU3 devices before 3.43.16 use session IDs for authentication but lack authorization checks. An attacker can obtain a session ID via an invalid login attempt to the RemoteApi account, aka HMCCU-154. This leads to automatic login as admin.
Garden is an automation platform for Kubernetes development and testing. In versions prior to 0.12.39 multiple endpoints did not require authentication. In some operating modes this allows for an attacker to gain access to the application erroneously. The configuration is leaked through the /api endpoint on the local server that is responsible for serving the Garden dashboard. At the moment, this server is accessible to 0.0.0.0 which makes it accessible to anyone on the same network (or anyone on the internet if they are on a public, static IP). This may lead to the ability to compromise credentials, secrets or environment variables. Users are advised to upgrade to version 0.12.39 as soon as possible. Users unable to upgrade should use a firewall blocking access to port 9777 from all untrusted network machines.
Dover Fueling Solutions ProGauge MagLink LX Consoles expose an undocumented and unauthenticated target communication framework (TCF) interface on a specific port. Files can be created, deleted, or modified, potentially leading to remote code execution.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the control service, which listens on TCP port 9999 by default. The issue results from the lack of authentication prior to allowing alterations to the system configuration. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-10493.
The KUKA SystemSoftware V/KSS in versions prior to 8.6.5 is prone to improper access control as an unauthorized attacker can directly read and write robot configurations when access control is not available or not enabled (default).
In Carlo Gavazzi UWP3.0 in multiple versions and CPY Car Park Server in Version 2.8.3 a missing authentication allows for full access via API.
NUUO NVRmini2 through 3.11 allows an unauthenticated attacker to upload an encrypted TAR archive, which can be abused to add arbitrary users because of the lack of handle_import_user.php authentication. When combined with another flaw (CVE-2011-5325), it is possible to overwrite arbitrary files under the web root and achieve code execution as root.
jupyter-lsp is a coding assistance tool for JupyterLab (code navigation + hover suggestions + linters + autocompletion + rename) using Language Server Protocol. Installations of jupyter-lsp running in environments without configured file system access control (on the operating system level), and with jupyter-server instances exposed to non-trusted network are vulnerable to unauthorised access and modification of file system beyond the jupyter root directory. This issue has been patched in version 2.2.2 and all users are advised to upgrade. Users unable to upgrade should uninstall jupyter-lsp.
SAP Cloud Connector, before version 2.11.3, does not perform any authentication checks for functionalities that require user identity.
Under certain circumstances, SAP HANA Extended Application Services, advanced model (XS advanced) does not perform authentication checks properly for XS advanced platform and business users. Fixed in 1.0.97 to 1.0.99 (running on SAP HANA 1 or SAP HANA 2 SPS0 (second S stands for stack)).
A lack of authentication vulnerability exists in the HTTP API functionality of GoCast 1.1.3. A specially crafted HTTP request can lead to arbitrary command execution. An attacker can make an unauthenticated HTTP request to trigger this vulnerability.
Vulnerability in the Oracle Web Applications Desktop Integrator product of Oracle E-Business Suite (component: Upload). Supported versions that are affected are 12.2.3-12.2.11. Easily exploitable vulnerability allows unauthenticated attacker with network access via HTTP to compromise Oracle Web Applications Desktop Integrator. Successful attacks of this vulnerability can result in takeover of Oracle Web Applications Desktop Integrator. CVSS 3.1 Base Score 9.8 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
Burk Technology ARC Solo's password change mechanism can be utilized without proper authentication procedures, allowing an attacker to take over the device. A password change request can be sent directly to the device's HTTP endpoint without providing valid credentials. The system does not enforce proper authentication or session validation, allowing the password change to proceed without verifying the request's legitimacy.
Missing Authentication in the registration feature of Lablup's BackendAI allows arbitrary users to create user accounts that can access private data even when registration is disabled.