A vulnerability has been identified in SiPass integrated AC5102 (ACC-G2) (All versions < V6.4.8), SiPass integrated ACC-AP (All versions < V6.4.8). Affected devices expose several MQTT URLs without authentication. This could allow an unauthenticated remote attacker to access sensitive data.
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). The AdminService is available without authentication on the Application Server. An attacker can use methods exposed via this interface to receive password hashes of other users and to change user passwords. Please note that an attacker needs to have access to the Application Highway in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0). The vulnerability could allow an unauthenticated attacker to reboot the device over the network by using special urls from integrated web server of the affected products.
A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046)
A vulnerability has been identified in TIA Administrator (All versions < V1.0 SP1 Upd1). The integrated configuration web application (TIA Administrator) allows to execute certain application commands without proper authentication. The vulnerability could be exploited by an attacker with local access to the affected system. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 and newer (All versions), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 and newer (All versions). An attacker with network access to affected installations, which are configured without "Encrypted Communication", can execute arbitrary code. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected installation. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in DIGSI 4 (All versions < V4.92), EN100 Ethernet module DNP3 variant (All versions < V1.05.00), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). The device engineering mechanism allows an unauthenticated remote user to upload a modified device configuration overwriting access authorization passwords.
A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with network access to port 69/udp could modify the firmware of the device.
A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with network access to port 69/udp could modify the administrative client stored on the device. If a legitimate user downloads and executes the modified client from the affected device, then he/she could obtain code execution on the client system.
A vulnerability has been identified in Desigo PXC00-E.D V4.10 (All versions < V4.10.111), Desigo PXC00-E.D V5.00 (All versions < V5.0.171), Desigo PXC00-E.D V5.10 (All versions < V5.10.69), Desigo PXC00-E.D V6.00 (All versions < V6.0.204), Desigo PXC00/64/128-U V4.10 (All versions < V4.10.111 only with web module), Desigo PXC00/64/128-U V5.00 (All versions < V5.0.171 only with web module), Desigo PXC00/64/128-U V5.10 (All versions < V5.10.69 only with web module), Desigo PXC00/64/128-U V6.00 (All versions < V6.0.204 only with web module), Desigo PXC001-E.D V4.10 (All versions < V4.10.111), Desigo PXC001-E.D V5.00 (All versions < V5.0.171), Desigo PXC001-E.D V5.10 (All versions < V5.10.69), Desigo PXC001-E.D V6.00 (All versions < V6.0.204), Desigo PXC100-E.D V4.10 (All versions < V4.10.111), Desigo PXC100-E.D V5.00 (All versions < V5.0.171), Desigo PXC100-E.D V5.10 (All versions < V5.10.69), Desigo PXC100-E.D V6.00 (All versions < V6.0.204), Desigo PXC12-E.D V4.10 (All versions < V4.10.111), Desigo PXC12-E.D V5.00 (All versions < V5.0.171), Desigo PXC12-E.D V5.10 (All versions < V5.10.69), Desigo PXC12-E.D V6.00 (All versions < V6.0.204), Desigo PXC200-E.D V4.10 (All versions < V4.10.111), Desigo PXC200-E.D V5.00 (All versions < V5.0.171), Desigo PXC200-E.D V5.10 (All versions < V5.10.69), Desigo PXC200-E.D V6.00 (All versions < V6.0.204), Desigo PXC22-E.D V4.10 (All versions < V4.10.111), Desigo PXC22-E.D V5.00 (All versions < V5.0.171), Desigo PXC22-E.D V5.10 (All versions < V5.10.69), Desigo PXC22-E.D V6.00 (All versions < V6.0.204), Desigo PXC22.1-E.D V4.10 (All versions < V4.10.111), Desigo PXC22.1-E.D V5.00 (All versions < V5.0.171), Desigo PXC22.1-E.D V5.10 (All versions < V5.10.69), Desigo PXC22.1-E.D V6.00 (All versions < V6.0.204), Desigo PXC36.1-E.D V4.10 (All versions < V4.10.111), Desigo PXC36.1-E.D V5.00 (All versions < V5.0.171), Desigo PXC36.1-E.D V5.10 (All versions < V5.10.69), Desigo PXC36.1-E.D V6.00 (All versions < V6.0.204), Desigo PXC50-E.D V4.10 (All versions < V4.10.111), Desigo PXC50-E.D V5.00 (All versions < V5.0.171), Desigo PXC50-E.D V5.10 (All versions < V5.10.69), Desigo PXC50-E.D V6.00 (All versions < V6.0.204), Desigo PXM20-E V4.10 (All versions < V4.10.111), Desigo PXM20-E V5.00 (All versions < V5.0.171), Desigo PXM20-E V5.10 (All versions < V5.10.69), Desigo PXM20-E V6.00 (All versions < V6.0.204). A remote attacker with network access to the device could potentially upload a new firmware image to the devices without prior authentication.
A vulnerability has been identified in EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module DNP3 variant (All versions < V1.04), EN100 Ethernet module PROFINET IO variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module IEC 104 variant (All versions < V1.22). The web interface (TCP/80) of affected devices allows an unauthenticated user to upgrade or downgrade the firmware of the device, including to older versions with known vulnerabilities.
A vulnerability has been identified in SICAM T (All versions < V3.0). The web based management interface of affected devices does not employ special access protection for certain internal developer views. This could allow unauthenticated users to extract internal configuration details.
A vulnerability has been identified in SICAM T (All versions < V3.0). The web based management interface of affected devices does not employ special access protection for certain internal developer views. This could allow authenticated users to access critical device information.
A vulnerability has been identified in SCALANCE X204RNA (HSR), SCALANCE X204RNA (PRP), SCALANCE X204RNA EEC (HSR), SCALANCE X204RNA EEC (PRP), SCALANCE X204RNA EEC (PRP/HSR), SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices contain a vulnerability that allows an unauthenticated attacker to violate access-control rules. The vulnerability can be triggered by sending GET request to specific uniform resource locator on the web configuration interface of the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. An attacker could use the vulnerability to obtain sensitive information or change the device configuration. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability was discovered in Siemens OZW672 (all versions) and OZW772 (all versions) that could allow an attacker to read and manipulate data in TLS sessions while performing a man-in-the-middle (MITM) attack on the integrated web server on port 443/tcp.
A vulnerability has been identified in Desigo CC (All versions if access from Installed Clients to Desigo CC server is allowed from networks outside of a highly protected zone), Desigo CC (All versions if access from Installed Clients to Desigo CC server is only allowed within highly protected zones). The affected server application fails to authenticate specific client requests. Modification of the client binary could allow an unauthenticated remote attacker to execute arbitrary SQL queries on the server database via the event port (default: 4998/tcp)
A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). An attacker with access to the device's web server might be able to execute administrative commands without authentication.
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.5). The affected systems allow any unauthenticated client to disconnect any active user from the server. An attacker could use this vulnerability to prevent any user to perform actions in the system, causing a denial of service situation.
The Aqara Cloud Developer Portal (developer.aqara.com) issued a developer token to any email address supplied by the attacker. This is an instance of "CWE-306: Missing Authentication for Critical Function" with an estimated CVSS of CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N (6.5 Medium). When combined with CVE-2026-50083, CVE-2026-50084, and CVE-2026-50085, any otherwise-unauthenticated attacker could execute a full takeover of affected devices.
Multiple versions of GARO Wallbox GLB/GTB/GTC are affected by incorrect access control. Lack of access control on the web manger pages allows any user to view and modify information.
The Datalogic DXU service on (for example) DL-Axist devices does not require authentication for configuration changes or disclosure of configuration settings.
Tad Book3 editing book page does not perform identity verification. Remote attackers can use the vulnerability to view and modify arbitrary content of books without permission.
openSIS through 7.4 has Incorrect Access Control.
The ISOinsight from Netvision has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to access certain system functions. These functions include viewing the administrator list, viewing and editing IP settings, and uploading files.
An issue was discovered in the WPGraphQL 0.2.3 plugin for WordPress. By querying the 'users' RootQuery, it is possible, for an unauthenticated attacker, to retrieve all WordPress users details such as email address, role, and username.
An authentication bypass vulnerability was identified in GitHub Enterprise Server that allowed an unauthenticated attacker to create a local user account, bypassing the configured external identity provider. When external authentication was enabled, the signup endpoint did not properly enforce the authentication restriction, allowing account creation and session establishment without identity provider validation. The created account was limited to the default base permissions configured on the instance. Exploitation required network access to a GHES instance configured with an external authentication provider. This vulnerability affected all versions of GitHub Enterprise Server prior to 3.21 and was fixed in versions 3.20.2, 3.19.6, 3.18.9, 3.17.15, and 3.16.18.
FreeScout is a free help desk and shared inbox built with PHP's Laravel framework. Prior to 1.8.212, the endpoint GET /thread/read/{conversation_id}/{thread_id} does not require authentication and does not validate whether the given thread_id belongs to the given conversation_id. This allows any unauthenticated attacker to mark any thread as read by passing arbitrary IDs, enumerate valid thread IDs via HTTP response codes (200 vs 404), and manipulate opened_at timestamps across conversations (IDOR). This vulnerability is fixed in 1.8.212.
Missing Authentication for Critical Function vulnerability in Drupal AJAX Dashboard allows Exploiting Incorrectly Configured Access Control Security Levels.This issue affects AJAX Dashboard: from 0.0.0 before 3.1.0.
Chartbrew is an open-source web application that can connect directly to databases and APIs and use the data to create charts. In version 4.9.0, the endpoint POST /user/invited does not validate any invite token, authentication header, or session. Any unauthenticated attacker can call this endpoint directly to create a fully active account and receive a valid JWT — even when the instance has existing users and signupRestricted is enabled. This bypass is distinct from the normal registration endpoint (POST /user) which enforces signupRestricted and sets active: false pending verification. This issue has been patched in version 5.0.0.
The BlueBubbles webhook handler in OpenClaw versions prior to 2026.2.21 contains a passwordless fallback authentication path that allows unauthenticated webhook events in certain reverse-proxy or local routing configurations. Attackers can bypass webhook authentication by exploiting the loopback/proxy heuristics to send unauthenticated webhook events to the BlueBubbles plugin.
Craft CMS is a content management system (CMS). From version 4.0.0-RC1 to before version 4.17.8 and from version 5.0.0-RC1 to before version 5.9.14, guest users can access Config Sync updater index, obtain signed data, and execute state-changing Config Sync actions (regenerate-yaml, apply-yaml-changes) without authentication. This issue has been patched in versions 4.17.8 and 5.9.14.
Indico is an event management system that uses Flask-Multipass, a multi-backend authentication system for Flask. In versions prior to 3.3.11, the API endpoint used to manage event series is missing an access check, allowing unauthenticated/unauthorized access to this endpoint. The impact of this is limited to getting the metadata (title, category chain, start/end date) for events in an existing series, deleting an existing event series, and modifying an existing event series. This vulnerability does NOT allow unauthorized access to events (beyond the basic metadata mentioned above), nor any kind of tampering with user-visible data in events. Version 3.3.11 fixes the issue. As a workaround, use the webserver to restrict access to the series management API endpoint.
The Link Whisper Free WordPress plugin before 0.9.1 has a publicly accessible REST endpoint that allows unauthenticated settings updates.
IBM Sterling B2B Integrator and IBM Sterling File Gateway 6.1.0.0 through 6.1.2.7_2, 6.2.0.0 through 6.2.0.5_1, 6.2.1.0 through 6.2.1.1_1, and 6.2.2.0 allows a remote unauthenticated attacker to view and delete the partners of a community and to delete the communities.
Dockyard is a Docker container management app. Prior to 1.1.0, Docker container start and stop operations are performed through GET requests without CSRF protection. A remote attacker can cause a logged-in administrator's browser to request /apps/action.php?action=stop&name=<container> or /apps/action.php?action=start&name=<container>, which starts or stops the target container. This vulnerability is fixed in 1.1.0.
The SSL Zen WordPress plugin before 4.6.0 does not properly prevent directory listing of the private keys folder, as it only relies on the use of .htaccess to prevent visitors from accessing the site's generated private keys, which allows an attacker to read them if the site runs on a server who doesn't support .htaccess files, like NGINX.
Missing Authentication for Critical Function vulnerability in Drupal Panels allows Exploiting Incorrectly Configured Access Control Security Levels.This issue affects Panels: from 0.0.0 before 4.9.0.
SonLogger before 6.4.1 is affected by user creation with any user permissions profile (e.g., SuperAdmin). An anonymous user can send a POST request to /User/saveUser without any authentication or session header.
A denial of service vulnerability exists in the Modbus RTU over TCP functionality of Socomec DIRIS Digiware M-70 1.6.9. A specially crafted network packet can lead to denial of service and weaken credentials resulting in default documented credentials being applied to the device. An attacker can send an unauthenticated packet to trigger this vulnerability.
Fluent Bit in_forward input plugin does not properly enforce the security.users authentication mechanism under certain configuration conditions. This allows remote attackers with network access to the Fluent Bit instance exposing the forward input to send unauthenticated data. By bypassing authentication controls, attackers can inject forged log records, flood alerting systems, or manipulate routing decisions, compromising the authenticity and integrity of ingested logs.
An issue was discovered in SquareBox CatDV Server through 9.2. An attacker can invoke sensitive RMI methods such as getConnections without authentication, the results of which can be used to generate valid authentication tokens. These tokens can then be used to invoke administrative tasks within the application, such as disclosing password hashes.
A Missing Authentication in Critical Function in Bosch IP cameras allows an unauthenticated remote attacker to extract sensitive information or change settings of the camera by sending crafted requests to the device. Only devices of the CPP6, CPP7 and CPP7.3 family with firmware 7.70, 7.72, and 7.80 prior to B128 are affected by this vulnerability. Versions 7.62 or lower and INTEOX cameras are not affected.
Trendnet AC2600 TEW-827DRU version 2.08B01 lacks proper authentication to the bittorrent functionality. If enabled, anyone is able to visit and modify settings and files via the Bittorent web client by visiting: http://192.168.10.1:9091/transmission/web/
Multiple vulnerabilities in Cisco Application Services Engine could allow an unauthenticated, remote attacker to gain privileged access to host-level operations or to learn device-specific information, create diagnostic files, and make limited configuration changes. For more information about these vulnerabilities, see the Details section of this advisory.
Cisco Finesse, Cisco Virtualized Voice Browser, and Cisco Unified CVP OpenSocial Gadget Editor Unauthenticated Access Vulnerability A vulnerability in the web management interface of Cisco Finesse, Cisco Virtualized Voice Browser, and Cisco Unified CVP could allow an unauthenticated, remote attacker to access the OpenSocial Gadget Editor without providing valid user credentials. The vulnerability is due to missing authentication for a specific section of the web-based management interface. An attacker could exploit this vulnerability by accessing a crafted URL. A successful exploit could allow the attacker to obtain access to a section of the interface, which they could use to obtain potentially confidential information and create arbitrary XML files. Cisco has released software updates that address this vulnerability. There are no workarounds that address this vulnerability.
Xvfb of SAP Business Objects Business Intelligence Platform, versions - 4.2, 4.3, platform on Unix does not perform any authentication checks for functionalities that require user identity.
IBM Planning Analytics Local 2.0 connects to a Redis server. The Redis server, an in-memory data structure store, running on the remote host is not protected by password authentication. A remote attacker can exploit this to gain unauthorized access to the server. IBM X-Force ID: 186401.
A vulnerability in the web-based management interface of Cisco Vision Dynamic Signage Director could allow an unauthenticated, remote attacker to access confidential information or make configuration changes. The vulnerability is due to missing authentication for a specific section of the web-based management interface. An attacker could exploit this vulnerability by accessing a crafted URL. A successful exploit could allow the attacker to obtain access to a section of the interface, which they could use to read confidential information or make configuration changes.
The Web CGI Script on ZyXEL LTE4506-M606 V1.00(ABDO.2)C0 devices does not require authentication, which allows remote unauthenticated attackers (via crafted JSON action data to /cgi-bin/gui.cgi) to use all features provided by the router. Examples: change the router password, retrieve the Wi-Fi passphrase, send an SMS message, or modify the IP forwarding to access the internal network.
The default configuration of Crimson 3.1 (Build versions prior to 3119.001) allows a user to be able to read and modify the database without authentication.