Issue summary: Applications performing certificate name checks (e.g., TLS clients checking server certificates) may attempt to read an invalid memory address resulting in abnormal termination of the application process. Impact summary: Abnormal termination of an application can a cause a denial of service. Applications performing certificate name checks (e.g., TLS clients checking server certificates) may attempt to read an invalid memory address when comparing the expected name with an `otherName` subject alternative name of an X.509 certificate. This may result in an exception that terminates the application program. Note that basic certificate chain validation (signatures, dates, ...) is not affected, the denial of service can occur only when the application also specifies an expected DNS name, Email address or IP address. TLS servers rarely solicit client certificates, and even when they do, they generally don't perform a name check against a reference identifier (expected identity), but rather extract the presented identity after checking the certificate chain. So TLS servers are generally not affected and the severity of the issue is Moderate. The FIPS modules in 3.3, 3.2, 3.1 and 3.0 are not affected by this issue.
A vulnerability has been identified in SIPROTEC 5 relays with CPU variants CP050 (All versions < V8.80), SIPROTEC 5 relays with CPU variants CP100 (All versions < V8.80), SIPROTEC 5 relays with CPU variants CP300 (All versions < V8.80). Received webpackets are not properly processed. An unauthenticated remote attacker with access to any of the Ethernet interfaces could send specially crafted packets to force a restart of the target device.
A vulnerability has been identified in SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations.
A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 Ready4Linux (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packet over port 102/tcp. A restart of the affected device is needed to restore normal operations.
A vulnerability has been identified in SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations.
fs/nfsd/trace.h in the Linux kernel before 5.13.4 might allow remote attackers to cause a denial of service (out-of-bounds read in strlen) by sending NFS traffic when the trace event framework is being used for nfsd.
Calling Buffer.fill() or Buffer.alloc() with some parameters can lead to a hang which could result in a Denial of Service. In order to address this vulnerability, the implementations of Buffer.alloc() and Buffer.fill() were updated so that they zero fill instead of hanging in these cases. All versions of Node.js 6.x (LTS "Boron"), 8.x (LTS "Carbon"), and 9.x are vulnerable. All versions of Node.js 10.x (Current) are NOT vulnerable.
The `'path'` module in the Node.js 4.x release line contains a potential regular expression denial of service (ReDoS) vector. The code in question was replaced in Node.js 6.x and later so this vulnerability only impacts all versions of Node.js 4.x. The regular expression, `splitPathRe`, used within the `'path'` module for the various path parsing functions, including `path.dirname()`, `path.extname()` and `path.parse()` was structured in such a way as to allow an attacker to craft a string, that when passed through one of these functions, could take a significant amount of time to evaluate, potentially leading to a full denial of service.
c-ares is an asynchronous resolver library. c-ares is vulnerable to denial of service. If a target resolver sends a query, the attacker forges a malformed UDP packet with a length of 0 and returns them to the target resolver. The target resolver erroneously interprets the 0 length as a graceful shutdown of the connection. This issue has been patched in version 1.19.1.
All versions of Node.js 9.x and 10.x are vulnerable and the severity is HIGH. An attacker can cause a denial of service (DoS) by causing a node process which provides an http server supporting TLS server to crash. This can be accomplished by sending duplicate/unexpected messages during the handshake. This vulnerability has been addressed by updating the TLS implementation.
All versions of Node.js 8.x, 9.x, and 10.x are vulnerable and the severity is HIGH. An attacker can cause a denial of service (DoS) by causing a node server providing an http2 server to crash. This can be accomplished by interacting with the http2 server in a manner that triggers a cleanup bug where objects are used in native code after they are no longer available. This has been addressed by updating the http2 implementation.
A vulnerability has been identified in OpenPCS 7 V7.1 and earlier (All versions), OpenPCS 7 V8.0 (All versions), OpenPCS 7 V8.1 (All versions < V8.1 Upd5), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd1), SIMATIC BATCH V7.1 and earlier (All versions), SIMATIC BATCH V8.0 (All versions < V8.0 SP1 Upd21), SIMATIC BATCH V8.1 (All versions < V8.1 SP1 Upd16), SIMATIC BATCH V8.2 (All versions < V8.2 Upd10), SIMATIC BATCH V9.0 (All versions < V9.0 SP1), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions < 15 SP1), SIMATIC PCS 7 V7.1 and earlier (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP1), SIMATIC Route Control V7.1 and earlier (All versions), SIMATIC Route Control V8.0 (All versions), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions < V9.0 Upd1), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Upd2), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Upd5), SIMATIC WinCC V7.2 and earlier (All versions < WinCC 7.2 Upd 15), SIMATIC WinCC V7.3 (All versions < WinCC 7.3 Upd 16), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 4), SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). Specially crafted messages sent to the RPC service of the affected products could cause a Denial-of-Service condition on the remote and local communication functionality of the affected products. A reboot of the system is required to recover the remote and local communication functionality. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
XStream is a Java library to serialize objects to XML and back again. In XStream before version 1.4.16, there is a vulnerability which may allow a remote attacker to occupy a thread that consumes maximum CPU time and will never return. No user is affected, who followed the recommendation to setup XStream's security framework with a whitelist limited to the minimal required types. If you rely on XStream's default blacklist of the Security Framework, you will have to use at least version 1.4.16.
Out-of-bounds Read vulnerability in mod_macro of Apache HTTP Server.This issue affects Apache HTTP Server: through 2.4.57.
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SINEC NMS (All versions < V4.0), SINEMA Remote Connect (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions), Totally Integrated Automation Portal (TIA Portal) V20 (All versions), User Management Component (UMC) (All versions < V2.15.1.1). Affected products contain a out of bound write buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition.
Improper Input Validation vulnerability in Apache Software Foundation Apache Traffic Server. The configuration option proxy.config.http.push_method_enabled didn't function. However, by default the PUSH method is blocked in the ip_allow configuration file.This issue affects Apache Traffic Server: from 8.0.0 through 9.2.0. 8.x users should upgrade to 8.1.7 or later versions 9.x users should upgrade to 9.2.1 or later versions
A vulnerability was found in Radare2 in version 5.3.1. Improper input validation when reading a crafted LE binary can lead to resource exhaustion and DoS.
A heap-based buffer overflow vulnerability was found in ImageMagick in versions prior to 7.0.11-14 in ReadTIFFImage() in coders/tiff.c. This issue is due to an incorrect setting of the pixel array size, which can lead to a crash and segmentation fault.
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SINEC NMS (All versions < V4.0), SINEMA Remote Connect (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions), Totally Integrated Automation Portal (TIA Portal) V20 (All versions), User Management Component (UMC) (All versions < V2.15.1.1). Affected products contain a out of bound read buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition.
An issue found in Frrouting bgpd v.8.4.2 allows a remote attacker to cause a denial of service via the bgp_attr_psid_sub() function.
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SINEC NMS (All versions < V4.0), SINEMA Remote Connect (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions), Totally Integrated Automation Portal (TIA Portal) V20 (All versions), User Management Component (UMC) (All versions < V2.15.1.1). Affected products contain a out of bound read buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition.
zlib before 1.2.12 allows memory corruption when deflating (i.e., when compressing) if the input has many distant matches.
If the `recursive-clients` quota is reached on a BIND 9 resolver configured with both `stale-answer-enable yes;` and `stale-answer-client-timeout 0;`, a sequence of serve-stale-related lookups could cause `named` to loop and terminate unexpectedly due to a stack overflow. This issue affects BIND 9 versions 9.16.33 through 9.16.41, 9.18.7 through 9.18.15, 9.16.33-S1 through 9.16.41-S1, and 9.18.11-S1 through 9.18.15-S1.
Laminas Diactoros provides PSR HTTP Message implementations. In versions 2.18.0 and prior, 2.19.0, 2.20.0, 2.21.0, 2.22.0, 2.23.0, 2.24.0, and 2.25.0, users who create HTTP requests or responses using laminas/laminas-diactoros, when providing a newline at the start or end of a header key or value, can cause an invalid message. This can lead to denial of service vectors or application errors. The problem has been patched in following versions 2.18.1, 2.19.1, 2.20.1, 2.21.1, 2.22.1, 2.23.1, 2.24.1, and 2.25.1. As a workaround, validate HTTP header keys and/or values, and if using user-supplied values, filter them to strip off leading or trailing newline characters before calling `withHeader()`.
hw/rdma/vmw/pvrdma_main.c in QEMU does not implement a read operation (such as uar_read by analogy to uar_write), which allows attackers to cause a denial of service (NULL pointer dereference).
The email-ingestion feature in Best Practical Request Tracker 4.1.13 through 4.4 allows denial of service by remote attackers via an algorithmic complexity attack on email address parsing.
In libexpat in Expat before 2.2.7, XML input including XML names that contain a large number of colons could make the XML parser consume a high amount of RAM and CPU resources while processing (enough to be usable for denial-of-service attacks).
In BIND 9.10.0 -> 9.11.21, 9.12.0 -> 9.16.5, 9.17.0 -> 9.17.3, also affects 9.10.5-S1 -> 9.11.21-S1 of the BIND 9 Supported Preview Edition, An attacker that can reach a vulnerable system with a specially crafted query packet can trigger a crash. To be vulnerable, the system must: * be running BIND that was built with "--enable-native-pkcs11" * be signing one or more zones with an RSA key * be able to receive queries from a possible attacker
A carefully crafted request uri-path can cause mod_proxy_uwsgi to read above the allocated memory and crash (DoS). This issue affects Apache HTTP Server versions 2.4.30 to 2.4.48 (inclusive).
The OPC UA implementations (ANSI C and C++) in affected products contain an integer overflow vulnerability that could cause the application to run into an infinite loop during certificate validation. This could allow an unauthenticated remote attacker to create a denial of service condition by sending a specially crafted certificate.
The html package (aka x/net/html) through 2018-09-25 in Go mishandles <table><math><select><mi><select></table>, leading to an infinite loop during an html.Parse call because inSelectIM and inSelectInTableIM do not comply with a specification.
The html package (aka x/net/html) through 2018-09-25 in Go mishandles <math><template><mn><b></template>, leading to a "panic: runtime error" (index out of range) in (*insertionModeStack).pop in node.go, called from inHeadIM, during an html.Parse call.
A vulnerability has been identified in SIPROTEC 5 6MD85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 6MD86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 6MD89 (CP300) (All versions >= V7.80 < V9.64), SIPROTEC 5 6MU85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7KE85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SA82 (CP100) (All versions < V8.90), SIPROTEC 5 7SA82 (CP150) (All versions < V9.40), SIPROTEC 5 7SA86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SA87 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SD82 (CP100) (All versions < V8.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.40), SIPROTEC 5 7SD86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SD87 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SJ81 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.40), SIPROTEC 5 7SJ82 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.40), SIPROTEC 5 7SJ85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SJ86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SK82 (CP100) (All versions < V8.89), SIPROTEC 5 7SK82 (CP150) (All versions < V9.40), SIPROTEC 5 7SK85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SL82 (CP100) (All versions < V8.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.40), SIPROTEC 5 7SL86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SL87 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SS85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7ST85 (CP300) (All versions >= V7.80 < V9.64), SIPROTEC 5 7ST86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SX82 (CP150) (All versions < V9.40), SIPROTEC 5 7SX85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7UM85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7UT82 (CP100) (All versions < V8.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.40), SIPROTEC 5 7UT85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7UT86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7UT87 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7VE85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7VK87 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7VU85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions < V9.40 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions < V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions < V9.40 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions < V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions < V9.40), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V9.40). Affected devices lack proper validation of http request parameters of the hosted web service. An unauthenticated remote attacker could send specially crafted packets that could cause denial of service condition of the target device.
In the GNU C Library (aka glibc or libc6) through 2.28, attempting to resolve a crafted hostname via getaddrinfo() leads to the allocation of a socket descriptor that is not closed. This is related to the if_nametoindex() function.
The html package (aka x/net/html) through 2018-09-17 in Go mishandles <math><template><mo><template>, leading to a "panic: runtime error" in parseCurrentToken in parse.go during an html.Parse call.
A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC712 (All versions < V2.1), SIMATIC Cloud Connect 7 CC716 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC716 (All versions < V2.1). The affected device is vulnerable to a denial of service while parsing a random (non-JSON) MQTT payload. This could allow an attacker who can manipulate the communication between the MQTT broker and the affected device to cause a denial of service (DoS).
The IEEE 802.11 parser in tcpdump before 4.9.3 has a buffer over-read in print-802_11.c for the Mesh Flags subfield.
Every `named` instance configured to run as a recursive resolver maintains a cache database holding the responses to the queries it has recently sent to authoritative servers. The size limit for that cache database can be configured using the `max-cache-size` statement in the configuration file; it defaults to 90% of the total amount of memory available on the host. When the size of the cache reaches 7/8 of the configured limit, a cache-cleaning algorithm starts to remove expired and/or least-recently used RRsets from the cache, to keep memory use below the configured limit. It has been discovered that the effectiveness of the cache-cleaning algorithm used in `named` can be severely diminished by querying the resolver for specific RRsets in a certain order, effectively allowing the configured `max-cache-size` limit to be significantly exceeded. This issue affects BIND 9 versions 9.11.0 through 9.16.41, 9.18.0 through 9.18.15, 9.19.0 through 9.19.13, 9.11.3-S1 through 9.16.41-S1, and 9.18.11-S1 through 9.18.15-S1.
The BGP parser in tcpdump before 4.9.3 has a buffer over-read in print-bgp.c:bgp_attr_print() (MP_REACH_NLRI).
Suricata before 5.0.7 and 6.x before 6.0.3 has a "critical evasion."
The SMB parser in tcpdump before 4.9.3 has buffer over-reads in print-smb.c:print_trans() for \MAILSLOT\BROWSE and \PIPE\LANMAN.
The html package (aka x/net/html) through 2018-09-25 in Go mishandles <svg><template><desc><t><svg></template>, leading to a "panic: runtime error" (index out of range) in (*nodeStack).pop in node.go, called from (*parser).clearActiveFormattingElements, during an html.Parse call.
The html package (aka x/net/html) before 2018-07-13 in Go mishandles "in frameset" insertion mode, leading to a "panic: runtime error" for html.Parse of <template><object>, <template><applet>, or <template><marquee>. This is related to HTMLTreeBuilder.cpp in WebKit.
A vulnerability has been identified in SIMATIC S7-400 CPU 412-1 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 DP V7 (All versions), SIMATIC S7-400 CPU 414-2 DP V7 (All versions), SIMATIC S7-400 CPU 414-3 DP V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416-2 DP V7 (All versions), SIMATIC S7-400 CPU 416-3 DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416F-2 DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 417-4 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions < V7.0.3), SIMATIC S7-400 H V4.5 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) (All versions < V6.0.9), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-410 CPU family (incl. SIPLUS variants) (All versions < V8.2.1), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), SIPLUS S7-400 CPU 416-3 V7 (All versions), SIPLUS S7-400 CPU 417-4 V7 (All versions). Specially crafted packets sent to port 102/tcp via Ethernet interface, via PROFIBUS, or via Multi Point Interfaces (MPI) could cause the affected devices to go into defect mode. Manual reboot is required to resume normal operation. Successful exploitation requires an attacker to be able to send specially crafted packets to port 102/tcp via Ethernet interface, via PROFIBUS or Multi Point Interfaces (MPI). No user interaction and no user privileges are required to exploit the security vulnerability. The vulnerability could allow causing a denial of service condition of the core functionality of the CPU, compromising the availability of the system.
The HNCP parser in tcpdump before 4.9.3 has a buffer over-read in print-hncp.c:print_prefix().
A vulnerability has been identified in SIMATIC S7-400 CPU 412-1 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 DP V7 (All versions), SIMATIC S7-400 CPU 414-2 DP V7 (All versions), SIMATIC S7-400 CPU 414-3 DP V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416-2 DP V7 (All versions), SIMATIC S7-400 CPU 416-3 DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416F-2 DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 417-4 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions < V7.0.3), SIMATIC S7-400 H V4.5 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) (All versions < V6.0.9), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-410 CPU family (incl. SIPLUS variants) (All versions < V8.2.1), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), SIPLUS S7-400 CPU 416-3 V7 (All versions), SIPLUS S7-400 CPU 417-4 V7 (All versions). Sending of specially crafted packets to port 102/tcp via Ethernet interface via PROFIBUS or Multi Point Interfaces (MPI) could cause a denial of service condition on affected devices. Flashing with a firmware image may be required to recover the CPU. Successful exploitation requires an attacker to have network access to port 102/tcp via Ethernet interface or to be able to send messages via PROFIBUS or Multi Point Interfaces (MPI) to the device. No user interaction is required. If no access protection is configured, no privileges are required to exploit the security vulnerability. The vulnerability could allow causing a denial of service condition of the core functionality of the CPU, compromising the availability of the system.
The DCCP parser in tcpdump before 4.9.3 has a buffer over-read in print-dccp.c:dccp_print_option().
The IKEv1 parser in tcpdump before 4.9.3 has a buffer over-read in print-isakmp.c:ikev1_n_print().
The html package (aka x/net/html) through 2018-09-17 in Go mishandles <template><tBody><isindex/action=0>, leading to a "panic: runtime error" in inBodyIM in parse.go during an html.Parse call.
The OSPFv3 parser in tcpdump before 4.9.3 has a buffer over-read in print-ospf6.c:ospf6_print_lshdr().