Cross Site Scripting (XSS) vulnerability in MetInfo 7.0.0 via the gourl parameter in login.php.
A vulnerability was found in PHPGurukul Taxi Stand Management System 1.0 and classified as problematic. Affected by this issue is some unknown functionality of the file /admin/search-autoortaxi.php. The manipulation of the argument searchdata leads to cross site scripting. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
A cross-site scripting (XSS) vulnerability in the referer parameter of Dzzoffice 2.02 allows attackers to execute arbitrary web scripts or HTML via a crafted payload.
IceWarp 11.4.6.0 was discovered to contain a cross-site scripting (XSS) vulnerability via the color parameter.
A reflected Cross Site Scripting (XSS) in wuzhicms v4.1.0 allows remote attackers to execute arbitrary web script or HTML via the imgurl parameter.
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists which could cause arbritrary script execution when a malicious file is read and displayed. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)
An issue was discovered in Arcserve Unified Data Protection (UDP) through 6.5 Update 4. There is a DDI-VRT-2018-21 Reflected Cross-site Scripting via /authenticationendpoint/domain.jsp issue.
The sanitize_string function in Zenphoto before 1.4.9 does not properly sanitize HTML tags, which allows remote attackers to perform a cross-site scripting (XSS) attack by wrapping a payload in "<<script></script>script>payload<script></script></script>", or in an image tag, with the payload as the onerror event.
ZTE MF971R product has reflective XSS vulnerability. An attacker could use the vulnerability to obtain cookie information.
jQuery v2.2.2 allows XSS via a crafted onerror attribute of an IMG element. NOTE: this vulnerability has been reported to be spam entry
Adobe Connect version 11.2.3 (and earlier) is affected by a reflected Cross-Site Scripting (XSS) vulnerability. If an attacker is able to convince a victim to visit a URL referencing a vulnerable page, malicious JavaScript content may be executed within the context of the victim's browser.
Improper neutralization of input in Nagvis before version 1.9.47 which can lead to XSS
The elementor-edit-template class in wp-admin/customize.php in the Elementor Pro plugin before 2.0.10 for WordPress has XSS.
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to a delete policy file. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)
Cross Site Scripting (XSS) vulnerability in the Showtime2 Slideshow module in CMS Made Simple (CMSMS) 2.2.4.
GNUBOARD5 5.3.1.9 has XSS that allows remote attackers to inject arbitrary web script or HTML via the "board tail contents" parameter, aka the adm/board_form_update.php bo_content_tail parameter.
Grafana 5.3.1 has XSS via a column style on the "Dashboard > Table Panel" screen. NOTE: this issue exists because of an incomplete fix for CVE-2018-12099.
Grafana 5.3.1 has XSS via the "Dashboard > Text Panel" screen. NOTE: this issue exists because of an incomplete fix for CVE-2018-12099.
Cross-site scripting vulnerabilities exist in the ssh_form.php script functionality of Advantech R-SeeNet v 2.4.12 (20.10.2020). If a user visits a specially crafted URL, it can lead to arbitrary JavaScript code execution in the context of the targeted user’s browser. An attacker can provide a crafted URL to trigger this vulnerability.
Fiyo CMS 2.0.7 has XSS via the dapur\apps\app_user\edit_user.php name parameter.
Multiple vulnerabilities in the web-based management interface of Cisco Identity Services Engine (ISE) Software could allow an attacker to conduct a cross-site scripting (XSS) attack against a user of the interface. For more information about these vulnerabilities, see the Details section of this advisory.
PHPgurukl Small CRM v.1.0 is vulnerable to Cross Site Scripting (XSS).
OP5 Monitor 8.3.1, 8.3.2, and OP5 8.3.3 are vulnerable to Cross Site Scripting (XSS).
A vulnerability has been found in 1000 Projects Sales Management System 1.0. Affected is an unknown function of the file /sales.php. The manipulation of the argument select2112 leads to cross site scripting. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
Proofpoint Insider Threat Management Server (formerly ObserveIT Server) before 7.11.1 allows stored XSS.
Cross-site scripting vulnerabilities exist in the telnet_form.php script functionality of Advantech R-SeeNet v 2.4.12 (20.10.2020). If a user visits a specially crafted URL, it can lead to arbitrary JavaScript code execution in the context of the targeted user’s browser. An attacker can provide a crafted URL to trigger this vulnerability.
GNUBOARD5 before 5.3.2.0 has XSS that allows remote attackers to inject arbitrary web script or HTML via the "board group extra contents" parameter, aka the adm/boardgroup_form_update.php gr_1~10 parameter.
OpenRefine is a free, open source tool for working with messy data. Prior to version 3.8.3, the built-in "Something went wrong!" error page includes the exception message and exception traceback without escaping HTML tags, enabling injection into the page if an attacker can reliably produce an error with an attacker-influenced message. It appears that the only way to reach this code in OpenRefine itself is for an attacker to somehow convince a victim to import a malicious file, which may be difficult. However, out-of-tree extensions may add their own calls to `respondWithErrorPage`. Version 3.8.3 has a fix for this issue.
Cross Site Scripting (XSS) vulnerability in gnuboard5 <=v5.3.2.8 via the url parameter to bbs/login.php.
Incomplete blacklist in sanitize_string in Zenphoto before 1.4.9 allows remote attackers to conduct cross-site scripting (XSS) attacks.
gaizhenbiao/chuanhuchatgpt project, version <=20240802 is vulnerable to stored Cross-Site Scripting (XSS) in WebSocket session transmission. An attacker can inject malicious content into a WebSocket message. When a victim accesses this session, the malicious JavaScript is executed in the victim's browser.
openBaraza HCM 3.1.6 does not properly neutralize user-controllable input: an unauthenticated remote attacker can conduct a stored cross-site scripting (XSS) attack against an administrative user from hr/subscription.jsp and hr/application.jsp and and hr/index.jsp (with view=).
Due to improper handling of uploaded images it is possible in very unlikely and rare conditions to force the agents browser to execute malicious javascript from a special crafted SVG file rendered as inline jpg file. This issue affects: ((OTRS)) Community Edition 5.0.x version 5.0.39 and prior versions; 6.0.x version 6.0.24 and prior versions. OTRS 7.0.x version 7.0.13 and prior versions.
Client-Side code injection through Feature Flag name in GitLab CE/EE starting with 11.9 allows a specially crafted feature flag name to PUT requests on behalf of other users via clicking on a link
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)
Reflected XSS vulnerability in Micro Focus Application Automation Tools Plugin - Jenkins plugin. The vulnerability affects all version 6.7 and earlier versions.
A bug exist in the input parameter of Access Manager that allows supply of invalid character to trigger cross-site scripting vulnerability. This affects NetIQ Access Manager 4.5 and 5.0
A vulnerability was identified in 1000 Projects Sales Management System 1.0. This issue affects some unknown processing of the file /superstore/admin/sales.php. The manipulation of the argument ssalescat leads to cross site scripting. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
A cross-site scripting (XSS) vulnerability in SAP J2EE Engine/7.01/Portal/EPP allows remote attackers to inject arbitrary web script via the wsdlLib parameter to /ctcprotocol/Protocol. NOTE: This vulnerability only affects products that are no longer supported by the maintainer
An issue was discovered in Open Ticket Request System (OTRS) 6.0.x before 6.0.12. An attacker could send an e-mail message with a malicious link to an OTRS system or an agent. If a logged-in agent opens this link, it could cause the execution of JavaScript in the context of OTRS.
The Simple Image Gallery WordPress plugin is vulnerable to Reflected Cross-Site Scripting via the msg parameter found in the ~/simple-image-gallery.php file which allows attackers to inject arbitrary web scripts, in versions up to and including 1.0.6.
The Bug Library WordPress plugin is vulnerable to Reflected Cross-Site Scripting via the successimportcount parameter found in the ~/bug-library.php file which allows attackers to inject arbitrary web scripts, in versions up to and including 2.0.3.
Cross Site Scripting (XSS) in Simiki v1.6.2.1 and prior allows remote attackers to execute arbitrary code via line 54 of the component 'simiki/blob/master/simiki/generators.py'.
A cross-site scripting (XSS) vulnerability in SAP J2EE Engine/7.01/Fiori allows remote attackers to inject arbitrary web script via the sys_jdbc parameter to /TestJDBC_Web/test2. NOTE: This vulnerability only affects products that are no longer supported by the maintainer
An XSS issue was discovered in Thycotic Secret Server before 10.7 (issue 1 of 2).
A vulnerability, which was classified as problematic, has been found in Portabilis i-Educar 2.9. This issue affects some unknown processing of the file /intranet/educar_avaliacao_desempenho_lst.php. The manipulation of the argument titulo_avaliacao leads to cross site scripting. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A CWE-79: Improper Neutralization of Input During Web Page Generation (Cross-siteScripting) through Cross-Site Request Forgery (CSRF) vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to impersonate the user who manages the charging station or carry out actions on their behalf when crafted malicious parameters are submitted to the charging station web server.
The H5P CSS Editor WordPress plugin is vulnerable to Reflected Cross-Site Scripting via the h5p-css-file parameter found in the ~/h5p-css-editor.php file which allows attackers to inject arbitrary web scripts, in versions up to and including 1.0.
A stored and reflected cross-site scripting (XSS) vulnerability in WiKID 2FA Enterprise Server through 4.2.0-b2047 allow remote attackers to inject arbitrary web script or HTML via /WiKIDAdmin/groups.jsp. The groupName parameter is vulnerable: the reflected cross-site scripting occurs immediately after the group is created. The malicious script is stored and will be executed again whenever /WiKIDAdmin/groups.jsp is visited.
The Image Optimizer by 10web WordPress plugin before 1.0.27 does not sanitise and escape the iowd_tabs_active parameter before rendering it in the plugin admin panel, leading to a reflected Cross-Site Scripting vulnerability, allowing an attacker to trick a logged in admin to execute arbitrary javascript by clicking a link.