Unlimited strcpy on user input when setting a locale file leads to stack buffer overflow in mIPC camera firmware 5.3.1.2003161406.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:mitre
Assigner Org ID:8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At:26 Sep, 2022 | 15:00
Updated At:22 May, 2025 | 13:58
Rejected At:
▼CVE Numbering Authority (CNA)

Unlimited strcpy on user input when setting a locale file leads to stack buffer overflow in mIPC camera firmware 5.3.1.2003161406.

Affected Products
Vendor
n/a
Product
n/a
Versions
Affected
  • n/a
Problem Types
TypeCWE IDDescription
textN/An/a
Type: text
CWE ID: N/A
Description: n/a
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://hackmd.io/%40_zOX-PXQQFmCETA_RZIgow/BkOhIU1oc
x_refsource_MISC
Hyperlink: https://hackmd.io/%40_zOX-PXQQFmCETA_RZIgow/BkOhIU1oc
Resource:
x_refsource_MISC
▼Authorized Data Publishers (ADP)
1. CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://hackmd.io/%40_zOX-PXQQFmCETA_RZIgow/BkOhIU1oc
x_refsource_MISC
x_transferred
Hyperlink: https://hackmd.io/%40_zOX-PXQQFmCETA_RZIgow/BkOhIU1oc
Resource:
x_refsource_MISC
x_transferred
2. CISA ADP Vulnrichment
Affected Products
Problem Types
TypeCWE IDDescription
CWECWE-787CWE-787 Out-of-bounds Write
Type: CWE
CWE ID: CWE-787
Description: CWE-787 Out-of-bounds Write
Metrics
VersionBase scoreBase severityVector
3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://hackmd.io/@_zOX-PXQQFmCETA_RZIgow/BkOhIU1oc
exploit
Hyperlink: https://hackmd.io/@_zOX-PXQQFmCETA_RZIgow/BkOhIU1oc
Resource:
exploit
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cve@mitre.org
Published At:26 Sep, 2022 | 16:15
Updated At:22 May, 2025 | 14:16

Unlimited strcpy on user input when setting a locale file leads to stack buffer overflow in mIPC camera firmware 5.3.1.2003161406.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Secondary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Secondary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
CPE Matches

mipcm
mipcm
>>mipc_camera_firmware>>5.3.1.2003161406
cpe:2.3:o:mipcm:mipc_camera_firmware:5.3.1.2003161406:*:*:*:*:*:*:*
mipcm
mipcm
>>mipc_camera>>-
cpe:2.3:h:mipcm:mipc_camera:-:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-787Primarynvd@nist.gov
CWE-787Secondary134c704f-9b21-4f2e-91b3-4a467353bcc0
CWE ID: CWE-787
Type: Primary
Source: nvd@nist.gov
CWE ID: CWE-787
Type: Secondary
Source: 134c704f-9b21-4f2e-91b3-4a467353bcc0
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://hackmd.io/%40_zOX-PXQQFmCETA_RZIgow/BkOhIU1occve@mitre.org
N/A
https://hackmd.io/%40_zOX-PXQQFmCETA_RZIgow/BkOhIU1ocaf854a3a-2127-422b-91ae-364da2661108
N/A
https://hackmd.io/@_zOX-PXQQFmCETA_RZIgow/BkOhIU1oc134c704f-9b21-4f2e-91b3-4a467353bcc0
N/A
Hyperlink: https://hackmd.io/%40_zOX-PXQQFmCETA_RZIgow/BkOhIU1oc
Source: cve@mitre.org
Resource: N/A
Hyperlink: https://hackmd.io/%40_zOX-PXQQFmCETA_RZIgow/BkOhIU1oc
Source: af854a3a-2127-422b-91ae-364da2661108
Resource: N/A
Hyperlink: https://hackmd.io/@_zOX-PXQQFmCETA_RZIgow/BkOhIU1oc
Source: 134c704f-9b21-4f2e-91b3-4a467353bcc0
Resource: N/A

Change History

0
Information is not available yet

Similar CVEs

396Records found

CVE-2025-8159
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.30% / 53.29%
||
7 Day CHG~0.00%
Published-25 Jul, 2025 | 14:32
Updated-16 Sep, 2025 | 19:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-513 HTTP POST Request formLanguageChange stack-based overflow

A vulnerability was found in D-Link DIR-513 1.0. It has been rated as critical. This issue affects the function formLanguageChange of the file /goform/formLanguageChange of the component HTTP POST Request Handler. The manipulation of the argument curTime leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-513dir-513_firmwareDIR-513
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2019-19988
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.78% / 73.26%
||
7 Day CHG~0.00%
Published-26 Feb, 2020 | 15:15
Updated-05 Aug, 2024 | 02:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in Selesta Visual Access Manager (VAM) 4.15.0 through 4.29. A user with valid credentials is able to create and write XML files on the filesystem via /common/vam_editXml.php in the web interface. The vulnerable PHP page checks none of these: the parameter that identifies the file name to be created, the destination path, or the extension. Thus, an attacker can manipulate the file name to create any type of file within the filesystem with arbitrary content.

Action-Not Available
Vendor-selingn/a
Product-visual_access_managern/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-63835
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-0.27% / 49.83%
||
7 Day CHG~0.00%
Published-10 Nov, 2025 | 00:00
Updated-18 Nov, 2025 | 17:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A stack-based buffer overflow vulnerability was discovered in Tenda AC18 v15.03.05.05_multi. The vulnerability exists in the guestSsid parameter of the /goform/WifiGuestSet interface. Remote attackers can exploit this vulnerability by sending oversized data to the guestSsid parameter, leading to denial of service (device crash) or potential remote code execution.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac18ac18_firmwaren/a
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-6111
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.14% / 33.98%
||
7 Day CHG~0.00%
Published-16 Jun, 2025 | 07:00
Updated-17 Jun, 2025 | 19:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1205 VirtualSer fromVirtualSer stack-based overflow

A vulnerability classified as critical was found in Tenda FH1205 2.0.0.7(775). This vulnerability affects the function fromVirtualSer of the file /goform/VirtualSer. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1205_firmwarefh1205FH1205
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-62164
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-8.8||HIGH
EPSS-0.11% / 29.38%
||
7 Day CHG~0.00%
Published-21 Nov, 2025 | 01:18
Updated-04 Dec, 2025 | 17:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
VLLM deserialization vulnerability leading to DoS and potential RCE

vLLM is an inference and serving engine for large language models (LLMs). From versions 0.10.2 to before 0.11.1, a memory corruption vulnerability could lead to a crash (denial-of-service) and potentially remote code execution (RCE), exists in the Completions API endpoint. When processing user-supplied prompt embeddings, the endpoint loads serialized tensors using torch.load() without sufficient validation. Due to a change introduced in PyTorch 2.8.0, sparse tensor integrity checks are disabled by default. As a result, maliciously crafted tensors can bypass internal bounds checks and trigger an out-of-bounds memory write during the call to to_dense(). This memory corruption can crash vLLM and potentially lead to code execution on the server hosting vLLM. This issue has been patched in version 0.11.1.

Action-Not Available
Vendor-vllmvllm-project
Product-vllmvllm
CWE ID-CWE-123
Write-what-where Condition
CWE ID-CWE-20
Improper Input Validation
CWE ID-CWE-502
Deserialization of Untrusted Data
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-6110
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.20% / 42.08%
||
7 Day CHG~0.00%
Published-16 Jun, 2025 | 06:31
Updated-17 Jun, 2025 | 19:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1201 SafeMacFilter stack-based overflow

A vulnerability classified as critical has been found in Tenda FH1201 1.2.0.14(408). This affects an unknown part of the file /goform/SafeMacFilter. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1201fh1201_firmwareFH1201
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2019-3921
Matching Score-4
Assigner-Tenable Network Security, Inc.
ShareView Details
Matching Score-4
Assigner-Tenable Network Security, Inc.
CVSS Score-8.8||HIGH
EPSS-5.49% / 90.02%
||
7 Day CHG~0.00%
Published-05 Mar, 2019 | 21:00
Updated-17 Sep, 2024 | 04:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The Alcatel Lucent I-240W-Q GPON ONT using firmware version 3FE54567BOZJ19 is vulnerable to a stack buffer overflow via crafted HTTP POST request sent by a remote, authenticated attacker to /GponForm/usb_Form?script/. An attacker can leverage this vulnerability to potentially execute arbitrary code.

Action-Not Available
Vendor-Tenable, Inc.Nokia Corporation
Product-i-240w-q_gpon_ont_firmwarei-240w-q_gpon_ontAlcatel Lucent I-240W-Q GPON ONT
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-49907
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-7.2||HIGH
EPSS-0.86% / 74.67%
||
7 Day CHG~0.00%
Published-09 Apr, 2024 | 14:12
Updated-04 Nov, 2025 | 19:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A stack-based buffer overflow vulnerability exists in the web interface Radio Scheduling functionality of Tp-Link AC1350 Wireless MU-MIMO Gigabit Access Point (EAP225 V3) v5.1.0 Build 20220926. A specially crafted series of HTTP requests can lead to remote code execution. An attacker can make an authenticated HTTP request to trigger this vulnerability.This vulnerability refers specifically to the overflow that occurs via the `band` parameter at offset `0x0045aad8` of the `httpd_portal` binary shipped with v5.1.0 Build 20220926 of the EAP225.

Action-Not Available
Vendor-TP-Link Systems Inc.
Product-eap115_firmwareeap225eap225_firmwareeap115AC1350 Wireless MU-MIMO Gigabit Access Point (EAP225 V3)N300 Wireless Access Point (EAP115)ac1350_firmwaren300_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-49913
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-7.2||HIGH
EPSS-0.86% / 74.67%
||
7 Day CHG~0.00%
Published-09 Apr, 2024 | 14:12
Updated-04 Nov, 2025 | 19:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A stack-based buffer overflow vulnerability exists in the web interface Radio Scheduling functionality of Tp-Link AC1350 Wireless MU-MIMO Gigabit Access Point (EAP225 V3) v5.1.0 Build 20220926. A specially crafted series of HTTP requests can lead to remote code execution. An attacker can make an authenticated HTTP request to trigger this vulnerability.This vulnerability refers specifically to the overflow that occurs via the `action` parameter at offset `0x422448` of the `httpd` binary shipped with v5.0.4 Build 20220216 of the EAP115.

Action-Not Available
Vendor-TP-Link Systems Inc.
Product-eap115_firmwareeap225eap225_firmwareeap115AC1350 Wireless MU-MIMO Gigabit Access Point (EAP225 V3)N300 Wireless Access Point (EAP115)ac1350_firmwaren300_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-49906
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-7.2||HIGH
EPSS-0.86% / 74.67%
||
7 Day CHG~0.00%
Published-09 Apr, 2024 | 14:12
Updated-04 Nov, 2025 | 19:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A stack-based buffer overflow vulnerability exists in the web interface Radio Scheduling functionality of Tp-Link AC1350 Wireless MU-MIMO Gigabit Access Point (EAP225 V3) v5.1.0 Build 20220926. A specially crafted series of HTTP requests can lead to remote code execution. An attacker can make an authenticated HTTP request to trigger this vulnerability.This vulnerability refers specifically to the overflow that occurs via the `ssid` parameter at offset `0x0045ab7c` of the `httpd_portal` binary shipped with v5.1.0 Build 20220926 of the EAP225.

Action-Not Available
Vendor-TP-Link Systems Inc.
Product-eap225eap225_firmwareAC1350 Wireless MU-MIMO Gigabit Access Point (EAP225 V3)N300 Wireless Access Point (EAP115)ac1350_firmwaren300_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-5978
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.35% / 57.12%
||
7 Day CHG~0.00%
Published-10 Jun, 2025 | 20:31
Updated-20 Jun, 2025 | 14:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1202 VirtualSer fromVirtualSer stack-based overflow

A vulnerability was found in Tenda FH1202 1.2.0.14. It has been classified as critical. Affected is the function fromVirtualSer of the file /goform/VirtualSer. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1202_firmwarefh1202FH1202
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-5934
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.05%
||
7 Day CHG~0.00%
Published-10 Jun, 2025 | 03:31
Updated-20 Jun, 2025 | 13:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Netgear EX3700 mtd sub_41619C stack-based overflow

A vulnerability was found in Netgear EX3700 up to 1.0.0.88. It has been classified as critical. Affected is the function sub_41619C of the file /mtd. The manipulation leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. Upgrading to version 1.0.0.98 is able to address this issue. It is recommended to upgrade the affected component. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-NETGEAR, Inc.
Product-ex3700ex3700_firmwareEX3700
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-49909
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-7.2||HIGH
EPSS-0.86% / 74.67%
||
7 Day CHG~0.00%
Published-09 Apr, 2024 | 14:12
Updated-04 Nov, 2025 | 19:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A stack-based buffer overflow vulnerability exists in the web interface Radio Scheduling functionality of Tp-Link AC1350 Wireless MU-MIMO Gigabit Access Point (EAP225 V3) v5.1.0 Build 20220926. A specially crafted series of HTTP requests can lead to remote code execution. An attacker can make an authenticated HTTP request to trigger this vulnerability.This vulnerability refers specifically to the overflow that occurs via the `action` parameter at offset `0x0045ab38` of the `httpd_portal` binary shipped with v5.1.0 Build 20220926 of the EAP225.

Action-Not Available
Vendor-TP-Link Systems Inc.
Product-eap225eap225_firmwareAC1350 Wireless MU-MIMO Gigabit Access Point (EAP225 V3)N300 Wireless Access Point (EAP115)ac1350_firmwaren300_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-5853
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.22% / 44.61%
||
7 Day CHG~0.00%
Published-09 Jun, 2025 | 00:31
Updated-09 Jun, 2025 | 19:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC6 SetRemoteWebCfg formSetSafeWanWebMan stack-based overflow

A vulnerability classified as critical was found in Tenda AC6 15.03.05.16. Affected by this vulnerability is the function formSetSafeWanWebMan of the file /goform/SetRemoteWebCfg. The manipulation of the argument remoteIp leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac6ac6_firmwareAC6
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-5863
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.21% / 43.16%
||
7 Day CHG~0.00%
Published-09 Jun, 2025 | 05:31
Updated-10 Jun, 2025 | 14:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC5 SetRebootTimer formSetRebootTimer stack-based overflow

A vulnerability was found in Tenda AC5 15.03.06.47. It has been classified as critical. Affected is the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac5ac5_firmwareAC5
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-5855
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.21% / 43.16%
||
7 Day CHG~0.00%
Published-09 Jun, 2025 | 01:31
Updated-09 Jun, 2025 | 19:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC6 SetRebootTimer formSetRebootTimer stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda AC6 15.03.05.16. This affects the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac6ac6_firmwareAC6
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-5847
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.15% / 35.39%
||
7 Day CHG~0.00%
Published-08 Jun, 2025 | 13:31
Updated-09 Jun, 2025 | 19:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC9 HTTP POST Request SetRemoteWebCfg formSetSafeWanWebMan stack-based overflow

A vulnerability has been found in Tenda AC9 15.03.02.13 and classified as critical. Affected by this vulnerability is the function formSetSafeWanWebMan of the file /goform/SetRemoteWebCfg of the component HTTP POST Request Handler. The manipulation of the argument remoteIp leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac9_firmwareac9AC9
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-26781
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-9.9||CRITICAL
EPSS-0.88% / 74.90%
||
7 Day CHG~0.00%
Published-12 May, 2022 | 17:01
Updated-15 Apr, 2025 | 19:01
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Multiple improper input validation vulnerabilities exists in the libnvram.so nvram_import functionality of InHand Networks InRouter302 V3.5.4. A specially-crafted file can lead to remote code execution. An attacker can send a sequence of requests to trigger this vulnerability.An improper input validation vulnerability exists in the `httpd`'s `user_define_print` function. Controlling the `user_define_timeout` nvram variable can lead to remote code execution.

Action-Not Available
Vendor-InHand Networks, Inc.
Product-ir302_firmwareir302InRouter302
CWE ID-CWE-20
Improper Input Validation
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-5619
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.49% / 64.96%
||
7 Day CHG+0.11%
Published-04 Jun, 2025 | 23:00
Updated-06 Jun, 2025 | 20:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda CH22 addUserName formaddUserName stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda CH22 1.0.0.1. This issue affects the function formaddUserName of the file /goform/addUserName. The manipulation of the argument Password leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ch22ch22_firmwareCH22
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-5685
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.27% / 50.39%
||
7 Day CHG+0.06%
Published-05 Jun, 2025 | 20:00
Updated-10 Jun, 2025 | 15:01
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda CH22 Natlimit formNatlimit stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda CH22 1.0.0.1. This affects the function formNatlimit of the file /goform/Natlimit. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ch22ch22_firmwareCH22
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-5572
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.29% / 52.03%
||
7 Day CHG+0.07%
Published-04 Jun, 2025 | 06:00
Updated-06 Jun, 2025 | 18:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DCS-932L setSystemEmail stack-based overflow

A vulnerability was found in D-Link DCS-932L 2.18.01. It has been declared as critical. Affected by this vulnerability is the function setSystemEmail of the file /setSystemEmail. The manipulation of the argument EmailSMTPPortNumber leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dcs-932ldcs-932l_firmwareDCS-932L
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-49908
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-7.2||HIGH
EPSS-0.86% / 74.67%
||
7 Day CHG~0.00%
Published-09 Apr, 2024 | 14:12
Updated-04 Nov, 2025 | 19:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A stack-based buffer overflow vulnerability exists in the web interface Radio Scheduling functionality of Tp-Link AC1350 Wireless MU-MIMO Gigabit Access Point (EAP225 V3) v5.1.0 Build 20220926. A specially crafted series of HTTP requests can lead to remote code execution. An attacker can make an authenticated HTTP request to trigger this vulnerability.This vulnerability refers specifically to the overflow that occurs via the `profile` parameter at offset `0x0045abc8` of the `httpd_portal` binary shipped with v5.1.0 Build 20220926 of the EAP225.

Action-Not Available
Vendor-TP-Link Systems Inc.
Product-eap225eap225_firmwareAC1350 Wireless MU-MIMO Gigabit Access Point (EAP225 V3)N300 Wireless Access Point (EAP115)ac1350_firmwaren300_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-5527
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.50% / 65.67%
||
7 Day CHG+0.12%
Published-03 Jun, 2025 | 20:31
Updated-09 Jun, 2025 | 15:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda RX3 SetStaticRouteCfg save_staticroute_data stack-based overflow

A vulnerability was found in Tenda RX3 16.03.13.11_multi_TDE01. It has been rated as critical. This issue affects the function save_staticroute_data of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-rx3_firmwarerx3RX3
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-49912
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-7.2||HIGH
EPSS-0.86% / 74.67%
||
7 Day CHG~0.00%
Published-09 Apr, 2024 | 14:12
Updated-04 Nov, 2025 | 19:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A stack-based buffer overflow vulnerability exists in the web interface Radio Scheduling functionality of Tp-Link AC1350 Wireless MU-MIMO Gigabit Access Point (EAP225 V3) v5.1.0 Build 20220926. A specially crafted series of HTTP requests can lead to remote code execution. An attacker can make an authenticated HTTP request to trigger this vulnerability.This vulnerability refers specifically to the overflow that occurs via the `profile` parameter at offset `0x4224b0` of the `httpd` binary shipped with v5.0.4 Build 20220216 of the EAP115.

Action-Not Available
Vendor-TP-Link Systems Inc.
Product-eap115_firmwareeap225eap225_firmwareeap115AC1350 Wireless MU-MIMO Gigabit Access Point (EAP225 V3)N300 Wireless Access Point (EAP115)ac1350_firmwaren300_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-49911
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-7.2||HIGH
EPSS-0.86% / 74.67%
||
7 Day CHG~0.00%
Published-09 Apr, 2024 | 14:12
Updated-04 Nov, 2025 | 19:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A stack-based buffer overflow vulnerability exists in the web interface Radio Scheduling functionality of Tp-Link AC1350 Wireless MU-MIMO Gigabit Access Point (EAP225 V3) v5.1.0 Build 20220926. A specially crafted series of HTTP requests can lead to remote code execution. An attacker can make an authenticated HTTP request to trigger this vulnerability.This vulnerability refers specifically to the overflow that occurs via the `band` parameter at offset `0x422420` of the `httpd` binary shipped with v5.0.4 Build 20220216 of the EAP115.

Action-Not Available
Vendor-TP-Link Systems Inc.
Product-eap115_firmwareeap225eap225_firmwareeap115AC1350 Wireless MU-MIMO Gigabit Access Point (EAP225 V3)N300 Wireless Access Point (EAP115)ac1350_firmwaren300_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-49910
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-7.2||HIGH
EPSS-0.86% / 74.67%
||
7 Day CHG~0.00%
Published-09 Apr, 2024 | 14:12
Updated-04 Nov, 2025 | 19:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A stack-based buffer overflow vulnerability exists in the web interface Radio Scheduling functionality of Tp-Link AC1350 Wireless MU-MIMO Gigabit Access Point (EAP225 V3) v5.1.0 Build 20220926. A specially crafted series of HTTP requests can lead to remote code execution. An attacker can make an authenticated HTTP request to trigger this vulnerability.This vulnerability refers specifically to the overflow that occurs via the `ssid` parameter at offset `0x42247c` of the `httpd` binary shipped with v5.0.4 Build 20220216 of the EAP115.

Action-Not Available
Vendor-TP-Link Systems Inc.
Product-eap115_firmwareeap225eap225_firmwareeap115AC1350 Wireless MU-MIMO Gigabit Access Point (EAP225 V3)N300 Wireless Access Point (EAP115)ac1350_firmwaren300_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-48725
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-7.2||HIGH
EPSS-31.01% / 96.62%
||
7 Day CHG~0.00%
Published-07 Mar, 2024 | 14:59
Updated-04 Nov, 2025 | 19:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A stack-based buffer overflow vulnerability exists in the JSON Parsing getblockschedule() functionality of Netgear RAX30 1.0.11.96 and 1.0.7.78. A specially crafted HTTP request can lead to code execution. An attacker can make an authenticated HTTP request to trigger this vulnerability.

Action-Not Available
Vendor-NETGEAR, Inc.
Product-rax30_firmwarerax30RAX30rax30_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4492
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.19% / 40.72%
||
7 Day CHG~0.00%
Published-05 May, 2024 | 00:31
Updated-27 Jan, 2025 | 18:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i21 setStaOffline formOfflineSet stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda i21 1.0.0.14(4656). This issue affects the function formOfflineSet of the file /goform/setStaOffline. The manipulation of the argument GO/ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-263081 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i21i21_firmwarei21
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-5080
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.39% / 59.27%
||
7 Day CHG+0.04%
Published-22 May, 2025 | 15:00
Updated-20 Jun, 2025 | 16:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH451 webExcptypemanFilter stack-based overflow

A vulnerability classified as critical has been found in Tenda FH451 1.0.0.9. Affected is the function webExcptypemanFilter of the file /goform/webExcptypemanFilter. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh451_firmwarefh451FH451
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-4843
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.13% / 32.84%
||
7 Day CHG~0.00%
Published-17 May, 2025 | 23:31
Updated-04 Jun, 2025 | 20:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DCS-932L udev SubUPnPCSInit stack-based overflow

A vulnerability was found in D-Link DCS-932L 2.18.01. It has been classified as critical. This affects the function SubUPnPCSInit of the file /sbin/udev. The manipulation of the argument CameraName leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dcs-932l_firmwaredcs-932lDCS-932L
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-4842
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.13% / 32.84%
||
7 Day CHG~0.00%
Published-17 May, 2025 | 23:00
Updated-04 Jun, 2025 | 20:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DCS-932L ucp isUCPCameraNameChanged stack-based overflow

A vulnerability was found in D-Link DCS-932L 2.18.01. It has been declared as critical. This vulnerability affects the function isUCPCameraNameChanged of the file /sbin/ucp. The manipulation of the argument CameraName leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dcs-932l_firmwaredcs-932lDCS-932L
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-4841
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.13% / 32.84%
||
7 Day CHG~0.00%
Published-17 May, 2025 | 22:31
Updated-03 Jun, 2025 | 15:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DCS-932L gpio sub_404780 stack-based overflow

A vulnerability was found in D-Link DCS-932L 2.18.01 and classified as critical. Affected by this issue is the function sub_404780 of the file /bin/gpio. The manipulation of the argument CameraName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dcs-932ldcs-932l_firmwareDCS-932L
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-26782
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-9.9||CRITICAL
EPSS-1.26% / 79.12%
||
7 Day CHG~0.00%
Published-12 May, 2022 | 17:01
Updated-15 Apr, 2025 | 19:01
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Multiple improper input validation vulnerabilities exists in the libnvram.so nvram_import functionality of InHand Networks InRouter302 V3.5.4. A specially-crafted file can lead to remote code execution. An attacker can send a sequence of requests to trigger this vulnerability.An improper input validation vulnerability exists in the `httpd`'s `user_define_set_item` function. Controlling the `user_define_timeout` nvram variable can lead to remote code execution.

Action-Not Available
Vendor-InHand Networks, Inc.
Product-ir302_firmwareir302InRouter302
CWE ID-CWE-20
Improper Input Validation
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-25753
Matching Score-4
Assigner-Siemens
ShareView Details
Matching Score-4
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-3.35% / 87.06%
||
7 Day CHG~0.00%
Published-12 Apr, 2022 | 09:07
Updated-03 Aug, 2024 | 04:49
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The handling of arguments such as IP addresses in the CLI of affected devices is prone to buffer overflows. This could allow an authenticated remote attacker to execute arbitrary code on the device.

Action-Not Available
Vendor-Siemens AG
Product-scalance_x308-2m_ts_firmwarescalance_x307-3_firmwarescalance_xr324-12mscalance_x310fescalance_x310fe_firmwarescalance_xr324-4m_eecscalance_x308-2ldscalance_x320-1fe_firmwaresiplus_net_scalance_x308-2scalance_xr324-4m_poe_firmwarescalance_x308-2scalance_x307-2eecscalance_xr324-4m_eec_firmwarescalance_x308-2_firmwarescalance_x304-2fe_firmwarescalance_xr324-12m_ts_firmwarescalance_x306-1ldfe_firmwarescalance_x307-2eec_firmwarescalance_x320-1-2ldfesiplus_net_scalance_x308-2_firmwarescalance_x308-2lh_firmwarescalance_x302-7eec_firmwarescalance_x308-2lhscalance_x307-3ld_firmwarescalance_x310scalance_x320-1-2ldfe_firmwarescalance_xr324-12m_firmwarescalance_x308-2m_poe_firmwarescalance_x310_firmwarescalance_x308-2m_poescalance_x308-2lh\+_firmwarescalance_x308-2ld_firmwarescalance_xr324-12m_tsscalance_x308-2m_tsscalance_x308-2m_firmwarescalance_x320-1fescalance_x408-2scalance_xr324-4m_poescalance_x306-1ldfescalance_x307-3ldscalance_x308-2mscalance_x408-2_firmwarescalance_x307-3scalance_x304-2fescalance_xr324-4m_poe_tsscalance_xr324-4m_poe_ts_firmwarescalance_x302-7eecscalance_x308-2lh\+SCALANCE XR324-12M TS (24V)SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)SCALANCE XR324-4M PoE (24V, ports on rear)SCALANCE XR324-4M EEC (24V, ports on front)SCALANCE XR324-12M (230V, ports on rear)SCALANCE X307-2 EEC (2x 24V, coated)SCALANCE XR324-4M PoE TS (24V, ports on front)SCALANCE X307-3SCALANCE X308-2MSCALANCE XR324-12M (24V, ports on rear)SCALANCE X308-2SCALANCE X308-2M PoESCALANCE X310FESCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)SCALANCE X308-2LH+SCALANCE X302-7 EEC (24V, coated)SCALANCE X307-2 EEC (230V, coated)SCALANCE X307-3LDSCALANCE X308-2LHSCALANCE XR324-4M EEC (24V, ports on rear)SCALANCE XR324-4M PoE (24V, ports on front)SCALANCE X302-7 EEC (2x 230V)SCALANCE X408-2SIPLUS NET SCALANCE X308-2SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)SCALANCE XR324-4M PoE (230V, ports on rear)SCALANCE X302-7 EEC (230V)SCALANCE X307-2 EEC (24V, coated)SCALANCE X307-2 EEC (2x 230V, coated)SCALANCE X302-7 EEC (2x 24V, coated)SCALANCE X308-2LDSCALANCE X307-2 EEC (24V)SCALANCE X304-2FESCALANCE X310SCALANCE X307-2 EEC (2x 24V)SCALANCE X307-2 EEC (230V)SCALANCE XR324-12M (24V, ports on front)SCALANCE X320-1 FESCALANCE X302-7 EEC (2x 24V)SCALANCE X306-1LD FESCALANCE X308-2M TSSCALANCE XR324-4M PoE (230V, ports on front)SCALANCE X307-2 EEC (2x 230V)SCALANCE X302-7 EEC (24V)SCALANCE X302-7 EEC (230V, coated)SCALANCE X302-7 EEC (2x 230V, coated)SCALANCE X320-1-2LD FESCALANCE XR324-4M EEC (2x 24V, ports on rear)SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)SCALANCE XR324-12M (230V, ports on front)SCALANCE XR324-4M EEC (2x 24V, ports on front)
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-4809
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.36% / 57.78%
||
7 Day CHG~0.00%
Published-16 May, 2025 | 20:00
Updated-24 May, 2025 | 01:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 setMacFilterCfg fromSafeSetMacFilter stack-based overflow

A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function fromSafeSetMacFilter of the file /goform/setMacFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-4810
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.36% / 57.78%
||
7 Day CHG~0.00%
Published-16 May, 2025 | 20:31
Updated-24 May, 2025 | 01:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 SetRebootTimer formSetRebootTimer stack-based overflow

A vulnerability was found in Tenda AC7 15.03.06.44. It has been declared as critical. Affected by this vulnerability is the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument reboot_time leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4244
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.36% / 57.53%
||
7 Day CHG~0.00%
Published-26 Apr, 2024 | 21:31
Updated-27 Jan, 2025 | 18:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W9 DhcpSetSer fromDhcpSetSer stack-based overflow

A vulnerability classified as critical was found in Tenda W9 1.0.0.7(4456). Affected by this vulnerability is the function fromDhcpSetSer of the file /goform/DhcpSetSer. The manipulation of the argument dhcpStartIp/dhcpEndIp/dhcpGw/dhcpMask/dhcpLeaseTime/dhcpDns1/dhcpDns2 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-262135. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w9w9_firmwareW9
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4170
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.83% / 74.21%
||
7 Day CHG~0.00%
Published-25 Apr, 2024 | 13:00
Updated-21 Jan, 2025 | 14:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda 4G300 sub_429A30 stack-based overflow

A vulnerability was found in Tenda 4G300 1.01.42. It has been rated as critical. This issue affects the function sub_429A30. The manipulation of the argument list1 leads to stack-based buffer overflow. The attack may be initiated remotely. The identifier VDB-261989 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-4g300_firmware4g3004G3004g300_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-25293
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-5.76% / 90.28%
||
7 Day CHG-0.18%
Published-24 Feb, 2022 | 04:55
Updated-03 Aug, 2024 | 04:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A systemd stack-based buffer overflow in WatchGuard Firebox and XTM appliances allows an authenticated remote attacker to potentially execute arbitrary code by initiating a firmware update with a malicious upgrade image. This vulnerability impacts Fireware OS before 12.7.2_U2, 12.x before 12.1.3_U8, and 12.2.x through 12.5.x before 12.5.9_U2.

Action-Not Available
Vendor-n/aWatchGuard Technologies, Inc.
Product-firewaren/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4114
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.15% / 35.16%
||
7 Day CHG~0.00%
Published-24 Apr, 2024 | 15:00
Updated-27 Jan, 2025 | 16:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda TX9 PowerSaveSet sub_42C014 stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda TX9 22.03.02.10. This issue affects the function sub_42C014 of the file /goform/PowerSaveSet. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261857 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-tx9_pro_firmwaretx9_proTX9tx9_pro_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-25292
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-4.13% / 88.41%
||
7 Day CHG~0.00%
Published-24 Feb, 2022 | 04:55
Updated-03 Aug, 2024 | 04:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A wgagent stack-based buffer overflow in WatchGuard Firebox and XTM appliances allows an authenticated remote attacker to potentially execute arbitrary code by initiating a firmware update with a malicious upgrade image. This vulnerability impacts Fireware OS before 12.7.2_U2, 12.x before 12.1.3_U8, and 12.2.x through 12.5.x before 12.5.9_U2.

Action-Not Available
Vendor-n/aWatchGuard Technologies, Inc.
Product-firewaren/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-45845
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.12% / 31.24%
||
7 Day CHG~0.00%
Published-08 May, 2025 | 00:00
Updated-16 May, 2025 | 15:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

TOTOLINK NR1800X V9.1.0u.6681_B20230703 was discovered to contain an authenticated stack overflow via the ssid5g parameter in the setWiFiEasyGuestCfg function.

Action-Not Available
Vendor-n/aTOTOLINK
Product-nr1800x_firmwarenr1800xn/a
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4112
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.32% / 54.35%
||
7 Day CHG~0.00%
Published-24 Apr, 2024 | 14:31
Updated-27 Jan, 2025 | 16:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda TX9 SetVirtualServerCfg sub_42CB94 stack-based overflow

A vulnerability classified as critical has been found in Tenda TX9 22.03.02.10. This affects the function sub_42CB94 of the file /goform/SetVirtualServerCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261855. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-tx9_pro_firmwaretx9_proTX9tx9_pro_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4121
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.22% / 44.81%
||
7 Day CHG~0.00%
Published-24 Apr, 2024 | 18:00
Updated-15 Jan, 2025 | 18:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W15E formQOSRuleDel stack-based overflow

A vulnerability classified as critical has been found in Tenda W15E 15.11.0.14. Affected is the function formQOSRuleDel. The manipulation of the argument qosIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The identifier of this vulnerability is VDB-261864. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w15e_firmwarew15eW15Ew15e_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-45843
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.12% / 31.24%
||
7 Day CHG~0.00%
Published-08 May, 2025 | 00:00
Updated-16 May, 2025 | 15:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

TOTOLINK NR1800X V9.1.0u.6681_B20230703 was discovered to contain an authenticated stack overflow via the ssid parameter in the setWiFiGuestCfg function.

Action-Not Available
Vendor-n/aTOTOLINK
Product-nr1800x_firmwarenr1800xn/a
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-45842
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.12% / 31.24%
||
7 Day CHG~0.00%
Published-08 May, 2025 | 00:00
Updated-16 May, 2025 | 15:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

TOTOLINK NR1800X V9.1.0u.6681_B20230703 was discovered to contain an authenticated stack overflow via the ssid5g parameter in the setWiFiEasyCfg function.

Action-Not Available
Vendor-n/aTOTOLINK
Product-nr1800x_firmwarenr1800xn/a
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4117
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.26% / 49.10%
||
7 Day CHG~0.00%
Published-24 Apr, 2024 | 16:00
Updated-15 Jan, 2025 | 18:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W15E DelPortMapping formDelPortMapping stack-based overflow

A vulnerability was found in Tenda W15E 15.11.0.14 and classified as critical. Affected by this issue is the function formDelPortMapping of the file /goform/DelPortMapping. The manipulation of the argument portMappingIndex leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261860. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w15e_firmwarew15eW15E
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4122
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.22% / 44.81%
||
7 Day CHG~0.00%
Published-24 Apr, 2024 | 18:00
Updated-15 Jan, 2025 | 18:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W15E setDebugCfg formSetDebugCfg stack-based overflow

A vulnerability classified as critical was found in Tenda W15E 15.11.0.14. Affected by this vulnerability is the function formSetDebugCfg of the file /goform/setDebugCfg. The manipulation of the argument enable/level/module leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261865 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w15e_firmwarew15eW15Ew15e
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-23561
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-8.8||HIGH
EPSS-0.18% / 38.87%
||
7 Day CHG~0.00%
Published-04 Feb, 2022 | 22:32
Updated-23 Apr, 2025 | 19:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Out of bounds write in TFLite

Tensorflow is an Open Source Machine Learning Framework. An attacker can craft a TFLite model that would cause a write outside of bounds of an array in TFLite. In fact, the attacker can override the linked list used by the memory allocator. This can be leveraged for an arbitrary write primitive under certain conditions. The fix will be included in TensorFlow 2.8.0. We will also cherrypick this commit on TensorFlow 2.7.1, TensorFlow 2.6.3, and TensorFlow 2.5.3, as these are also affected and still in supported range.

Action-Not Available
Vendor-Google LLCTensorFlow
Product-tensorflowtensorflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3906
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.61% / 69.28%
||
7 Day CHG~0.00%
Published-17 Apr, 2024 | 10:31
Updated-21 Jan, 2025 | 18:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC500 QuickIndex formQuickIndex stack-based overflow

A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been declared as critical. This vulnerability affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-261142 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac500ac500_firmwareAC500ac500
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
  • Previous
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • Next
Details not found