The official drupal docker images before 8.5.10-fpm-alpine (Alpine specific) contain a blank password for a root user. System using the drupal docker container deployed by affected versions of the docker image may allow a remote attacker to achieve root access with a blank password.
A Missing Authentication for Critical Function vulnerability in SUSE Manager allows anyone with access to the websocket at /rhn/websocket/minion/remote-commands to execute arbitrary commands as root. This issue affects Container suse/manager/5.0/x86_64/server:5.0.5.7.30.1: from ? before 0.3.7-150600.3.6.2; Container suse/manager/5.0/x86_64/server:5.0.5.7.30.1: from ? before 5.0.14-150600.4.17.1; Container suse/manager/5.0/x86_64/server:5.0.5.7.30.1: from ? before 5.0.14-150600.4.17.1; Image SLES15-SP4-Manager-Server-4-3-BYOS: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Server-4-3-BYOS: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Server-4-3-BYOS-Azure: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Server-4-3-BYOS-Azure: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Server-4-3-BYOS-EC2: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Server-4-3-BYOS-EC2: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Server-4-3-BYOS-GCE: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Server-4-3-BYOS-GCE: from ? before 4.3.33-150400.3.55.2; SUSE Manager Server Module 4.3: from ? before 0.3.7-150400.3.39.4; SUSE Manager Server Module 4.3: from ? before 4.3.33-150400.3.55.2; SUSE Manager Server Module 4.3: from ? before 4.3.33-150400.3.55.2.
An issue discovered in Shenzhen Zhiboton Electronics ZBT WE1626 Router v 21.06.18 allows attackers to escalate privileges via WGET command to the Network Diagnosis endpoint.
WGS-80HPT-V2 and WGS-4215-8T2S are missing authentication that could allow an attacker to create an administrator account without knowing any existing credentials.
D-Link DIR-822+ V1.0.2 contains a login bypass in the HNAP1 interface, which allows attackers to log in to administrator accounts with empty passwords.
Telepad allows remote unauthenticated users to send instructions to the server to execute arbitrary code without any previous authorization or authentication. CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summer Baby Zoom Wifi Monitor & Internet Viewing System allows remote attackers to bypass authentication, related to the MySnapCam web service.
Missing authentication checks in the query.fcgi endpoint of NS3000 v8.1.1.125110 , v7.2.8.124852 , and v7.x and NS2000 v7.02.08 allows attackers to execute a session hijacking attack.
Certain NETGEAR devices are affected by authentication bypass. This affects WAC505 before 5.0.0.17 and WAC510 before 5.0.0.17.
Improper Authentication vulnerability in Abdul Hakeem Build App Online allows Privilege Escalation.This issue affects Build App Online: from n/a through 1.0.19.
An issue was discovered in CommScope Ruckus IoT Controller 1.7.1.0 and earlier. There are Unauthenticated API Endpoints.
Multiple camera devices by UDP Technology, Geutebrück and other vendors allow unauthenticated remote access to sensitive files due to default user authentication settings. This can lead to manipulation of the device and denial of service.
The web management interface of Okcat Parking Management Platform from ZONG YU has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to directly access system functions. These functions include opening gates, viewing license plates and parking records, and restarting the system.
NETGEAR ProSAFE Network Management System has Java Debug Wire Protocol (JDWP) listening on port 11611 and it is remotely accessible by unauthenticated users, allowing attackers to execute arbitrary code.
There is an arbitrary password modification vulnerability in a D-LINK DSL-2888A router product. An attacker can use this vulnerability to modify the password of the admin user without authorization.
AVEVA System Platform versions 2017 through 2020 R2 P01 does not perform any authentication for functionality that requires a provable user identity.
The router console is accessible without authentication at "data" field, and while a user needs to be logged in in order to modify the configuration, the session state is shared. If any other user is currently logged in, the anonymous user can execute commands in the context of the authenticated one. If the logged in user has administrative privileges, it is possible to use webadmin service configuration commands to create a new admin user with a chosen password.
Due to missing authentication on a critical function of the devices an unauthenticated remote attacker can execute arbitrary commands, potentially enabling unauthorized upload or download of configuration files and leading to full system compromise.
A vulnerability has been identified in SINEC NMS (All versions < V4.0). The affected application exposes an endpoint that allows an unauthorized modification of administrative credentials. This could allow an unauthenticated attacker to reset the superadmin password and gain full control of the application (ZDI-CAN-26569).
The affected product’s configuration is vulnerable due to missing authentication, which may allow an attacker to change configurations and execute arbitrary code on the iView (versions prior to v5.7.03.6182).
Missing authentication for critical function vulnerability in First Corporation's DVRs allows a remote unauthenticated attacker to rewrite or obtain the configuration information of the affected device. Note that updates are provided only for Late model of CFR-4EABC, CFR-4EAB, CFR-8EAB, CFR-16EAB, MD-404AB, and MD-808AB. As for the other products, apply the workaround.
The Telnet service of the SIMATIC HMI Comfort Panels system component in affected products does not require authentication, which may allow a remote attacker to gain access to the device if the service is enabled. Telnet is disabled by default on the SINAMICS Medium Voltage Products (SINAMICS SL150: All versions, SINAMICS SM150: All versions, SINAMICS SM150i: All versions).
Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation G-50 Version 3.37 and prior, G-50-W Version 3.37 and prior, G-50A Version 3.37 and prior, GB-50 Version 3.37 and prior, GB-50A Version 3.37 and prior, GB-24A Version 9.12 and prior, G-150AD Version 3.21 and prior, AG-150A-A Version 3.21 and prior, AG-150A-J Version 3.21 and prior, GB-50AD Version 3.21 and prior, GB-50ADA-A Version 3.21 and prior, GB-50ADA-J Version 3.21 and prior, EB-50GU-A Version 7.11 and prior, EB-50GU-J Version 7.11 and prior, AE-200J Version 8.01 and prior, AE-200A Version 8.01 and prior, AE-200E Version 8.01 and prior, AE-50J Version 8.01 and prior, AE-50A Version 8.01 and prior, AE-50E Version 8.01 and prior, EW-50J Version 8.01 and prior, EW-50A Version 8.01 and prior, EW-50E Version 8.01 and prior, TE-200A Version 8.01 and prior, TE-50A Version 8.01 and prior, TW-50A Version 8.01 and prior, and CMS-RMD-J Version 1.40 and prior allows a remote unauthenticated attacker to bypass authentication and then control the air conditioning systems illegally, or disclose information in them by exploiting this vulnerability. In addition, the attacker may tamper with firmware for them using the disclosed information.
IBM Spectrum Protect Server 8.1 through 8.1.26 could allow attacker to bypass authentication due to improper session authentication which can result in access to unauthorized resources.
authentik is an open-source Identity Provider. Prior to versions 2023.8.4 and 2023.10.2, when the default admin user has been deleted, it is potentially possible for an attacker to set the password of the default admin user without any authentication. authentik uses a blueprint to create the default admin user, which can also optionally set the default admin users' password from an environment variable. When the user is deleted, the `initial-setup` flow used to configure authentik after the first installation becomes available again. authentik 2023.8.4 and 2023.10.2 fix this issue. As a workaround, ensure the default admin user (Username `akadmin`) exists and has a password set. It is recommended to use a very strong password for this user, and store it in a secure location like a password manager. It is also possible to deactivate the user to prevent any logins as akadmin.
Authentication Bypass Using an Alternate Path or Channel vulnerability in Yepas Digital Yepas allows Authentication Bypass.This issue affects Digital Yepas: before 1.0.1.
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability that could allow an attacker to achieve unauthenticated remote code execution in the context of an administrator.
Langflow versions prior to 1.3.0 are susceptible to code injection in the /api/v1/validate/code endpoint. A remote and unauthenticated attacker can send crafted HTTP requests to execute arbitrary code.
The previous default setting for Airflow's Experimental API was to allow all API requests without authentication, but this poses security risks to users who miss this fact. From Airflow 1.10.11 the default has been changed to deny all requests by default and is documented at https://airflow.apache.org/docs/1.10.11/security.html#api-authentication. Note this change fixes it for new installs but existing users need to change their config to default `[api]auth_backend = airflow.api.auth.backend.deny_all` as mentioned in the Updating Guide: https://github.com/apache/airflow/blob/1.10.11/UPDATING.md#experimental-api-will-deny-all-request-by-default
NetAlertX is a network, presence scanner and alert framework. Prior to version 25.4.14, it is possible to bypass the authentication mechanism of NetAlertX to update settings without authentication. An attacker can trigger sensitive functions within util.php by sending crafted requests to /index.php. This issue has been patched in version 25.4.14.
Enterprise Cloud Database from Ragic does not authenticate access to specific functionality, allowing unauthenticated remote attackers to use this functionality to obtain any user's session cookie.
Burk Technology ARC Solo's password change mechanism can be utilized without proper authentication procedures, allowing an attacker to take over the device. A password change request can be sent directly to the device's HTTP endpoint without providing valid credentials. The system does not enforce proper authentication or session validation, allowing the password change to proceed without verifying the request's legitimacy.
The SMS Alert Order Notifications – WooCommerce plugin for WordPress is vulnerable to privilege escalation via account takeover in all versions up to, and including, 3.7.9. This is due to the plugin using the Host header to determine if the plugin is in a playground environment. This makes it possible for unauthenticated attackers to spoof the Host header to make the OTP code "1234" and authenticate as any user, including administrators.
A security vulnerability has been identified in the HPE Edgeline Infrastructure Manager, also known as HPE Edgeline Infrastructure Management Software, prior to version 1.22. The vulnerability could be remotely exploited to bypass remote authentication leading to execution of arbitrary commands, gaining privileged access, causing denial of service, and changing the configuration. HPE has released a software update to resolve the vulnerability in the HPE Edgeline Infrastructure Manager.
Vulnerability of access permissions not being strictly verified in the APPWidget module.Successful exploitation of this vulnerability may cause some apps to run without being authorized.
BAB TECHNOLOGIE GmbH eibPort V3 prior version 3.9.1 allow unauthenticated attackers access to /webif/SecurityModule to validate the so called and hard coded unique 'eibPort String' which acts as the root SSH key passphrase. This is usable and part of an attack chain to gain SSH root access.
Red Lion SixTRAK and VersaTRAK Series RTUs with authenticated users enabled (UDR-A) any Sixnet UDR message will meet an authentication challenge over UDP/IP. When the same message is received over TCP/IP the RTU will simply accept the message with no authentication challenge.
In JetBrains TeamCity before 2023.05.4 authentication bypass leading to RCE on TeamCity Server was possible
An improper access control vulnerability has been reported to affect certain legacy versions of HBS 3. If exploited, this vulnerability allows attackers to compromise the security of the operating system.QNAP have already fixed this vulnerability in the following versions of HBS 3: QTS 4.3.6: HBS 3 v3.0.210507 and later QTS 4.3.4: HBS 3 v3.0.210506 and later QTS 4.3.3: HBS 3 v3.0.210506 and later
There is no account authentication and permission check logic in the firmware and existing apps of SiHAS's SGW-300, ACM-300, GCM-300, so unauthorized users can remotely control the device.
Vulnerability in the Oracle Scripting product of Oracle E-Business Suite (component: iSurvey Module). Supported versions that are affected are 12.2.3-12.2.14. Easily exploitable vulnerability allows unauthenticated attacker with network access via HTTP to compromise Oracle Scripting. Successful attacks of this vulnerability can result in takeover of Oracle Scripting. CVSS 3.1 Base Score 9.8 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
An issue was discovered in genua genugate before 9.0 Z p19, 9.1.x through 9.6.x before 9.6 p7, and 10.x before 10.1 p4. The Web Interfaces (Admin, Userweb, Sidechannel) can use different methods to perform the authentication of a user. A specific authentication method during login does not check the provided data (when a certain manipulation occurs) and returns OK for any authentication request. This allows an attacker to login to the admin panel as a user of his choice, e.g., the root user (with highest privileges) or even a non-existing user.
Authentication bypass when an OAuth2 Client is using client_secret_jwt as its authentication method on affected 11.3 versions via specially crafted requests.
A first-factor authentication bypass vulnerability exists in the PingFederate with PingID Radius PCV when a MSCHAP authentication request is sent via a maliciously crafted RADIUS client request.
Even if the authentication fails for local service authentication, the requested command could still execute regardless of authentication status.
Arbitrary code execution vulnerability on Micro Focus Operation Bridge Reporter, affecting version 10.40 and earlier. The vulnerability could allow remote attackers to execute arbitrary code on affected installations of OBR.
An issue was discovered in BACKCLICK Professional 5.9.63. User authentication for accessing the CORBA back-end services can be bypassed.
Windows Mobile Device Management Elevation of Privilege Vulnerability
If Apache TomEE is configured to use the embedded ActiveMQ broker, and the broker URI includes the useJMX=true parameter, a JMX port is opened on TCP port 1099, which does not include authentication. This affects Apache TomEE 8.0.0-M1 - 8.0.1, Apache TomEE 7.1.0 - 7.1.2, Apache TomEE 7.0.0-M1 - 7.0.7, Apache TomEE 1.0.0 - 1.7.5.
Vasion Print (formerly PrinterLogic) before Virtual Appliance Host 22.0.933 Application 20.0.2368 allows Unauthenticated Driver Package Editing V-2024-008.