Vulnerability in the Oracle WebLogic Server product of Oracle Fusion Middleware (component: Core). Supported versions that are affected are 12.2.1.4.0 and 14.1.1.0.0. Easily exploitable vulnerability allows unauthenticated attacker with network access via T3, IIOP to compromise Oracle WebLogic Server. Successful attacks of this vulnerability can result in unauthorized access to critical data or complete access to all Oracle WebLogic Server accessible data. CVSS 3.1 Base Score 7.5 (Confidentiality impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).
Vulnerability in the Oracle WebLogic Server product of Oracle Fusion Middleware (component: Core). Supported versions that are affected are 12.2.1.4.0 and 14.1.1.0.0. Easily exploitable vulnerability allows unauthenticated attacker with network access via T3, IIOP to compromise Oracle WebLogic Server. Successful attacks of this vulnerability can result in unauthorized access to critical data or complete access to all Oracle WebLogic Server accessible data. CVSS 3.1 Base Score 7.5 (Confidentiality impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).
A Missing Authentication for Critical Function vulnerability combined with a Generation of Error Message Containing Sensitive Information vulnerability in J-Web of Juniper Networks Junos OS on SRX Series and EX Series allows an unauthenticated, network-based attacker to access sensitive system information. When a user logs in, a temporary file which contains the configuration of the device (as visible to that user) is created in the /cache folder. An unauthenticated attacker can then attempt to access such a file by sending a specific request to the device trying to guess the name of such a file. Successful exploitation will reveal configuration information. This issue affects Juniper Networks Junos OS on SRX Series and EX Series: * All versions earlier than 20.4R3-S9; * 21.2 versions earlier than 21.2R3-S7; * 21.3 versions earlier than 21.3R3-S5; * 21.4 versions earlier than 21.4R3-S6; * 22.1 versions earlier than 22.1R3-S5; * 22.2 versions earlier than 22.2R3-S3; * 22.3 versions earlier than 22.3R3-S2; * 22.4 versions earlier than 22.4R3; * 23.2 versions earlier than 23.2R1-S2, 23.2R2.
A vulnerability classified as problematic has been found in SourceCodester Book Store Management System 1.0. This affects an unknown part of the file /bsms_ci/index.php/user/edit_user/. The manipulation of the argument password leads to information disclosure. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-214587.
Vulnerability in the Oracle WebLogic Server product of Oracle Fusion Middleware (component: Core). Supported versions that are affected are 12.2.1.4.0 and 14.1.1.0.0. Easily exploitable vulnerability allows unauthenticated attacker with network access via T3, IIOP to compromise Oracle WebLogic Server. Successful attacks of this vulnerability can result in unauthorized access to critical data or complete access to all Oracle WebLogic Server accessible data. CVSS 3.1 Base Score 7.5 (Confidentiality impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).
Missing Authentication for Critical Function vulnerability in Honeywell OneWireless allows Authentication Bypass. This issue affects OneWireless version 322.1
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to access the aprunning endpoint, which could allow an attacker to retrieve any file from the “RunningConfigs” directory. The attacker could then view and modify configuration files such as UserListInfo.xml, which would allow them to see existing administrative passwords.
Missing authentication for critical function in Windows Remote Desktop Licensing Service allows an unauthorized attacker to bypass a security feature over a network.
The health module has insufficient restrictions on loading URLs, which may lead to some information leakage.
Vulnerability in the Oracle Access Manager product of Oracle Fusion Middleware (component: Admin Console). The supported version that is affected is 12.2.1.4.0. Easily exploitable vulnerability allows unauthenticated attacker with network access via HTTP to compromise Oracle Access Manager. Successful attacks of this vulnerability can result in unauthorized access to critical data or complete access to all Oracle Access Manager accessible data. CVSS 3.1 Base Score 7.5 (Confidentiality impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).
The WMS module lacks the authentication mechanism in some APIs. Successful exploitation of this vulnerability may affect data confidentiality.
The MinigameCenter module has insufficient restrictions on loading URLs, which may lead to some information leakage.
All FLIR AX8 thermal sensor cameras version up to and including 1.46.16 are affected by an insecure design vulnerability due to an improper directory access restriction. An unauthenticated, remote attacker can exploit this by sending a URI that contains the path of the SQLite users database and download it. A successful exploit could allow the attacker to extract usernames and hashed passwords.
An issue was discovered in the A4N (Aremis 4 Nomad) application 1.5.0 for Android. It possesses an authentication mechanism; however, some features do not require any token or cookie in a request. Therefore, an attacker may send a simple HTTP request to the right endpoint, and obtain authorization to retrieve application data.
A vulnerability has been identified in SIMATIC MV540 H (All versions < V3.3), SIMATIC MV540 S (All versions < V3.3), SIMATIC MV550 H (All versions < V3.3), SIMATIC MV550 S (All versions < V3.3), SIMATIC MV560 U (All versions < V3.3), SIMATIC MV560 X (All versions < V3.3). Affected devices do not perform authentication for several web API endpoints. This could allow an unauthenticated remote attacker to read and download data from the device.
OpenClinic version 0.8.2 is affected by a missing authentication vulnerability that allows unauthenticated users to access any patient's medical test results, possibly resulting in disclosure of Protected Health Information (PHI) stored in the application, via a direct request for the /tests/ URI.
Splunk Enterprise deployment servers in versions before 9.0 allow unauthenticated downloading of forwarder bundles. Remediation requires you to update the deployment server to version 9.0 and Configure authentication for deployment servers and clients (https://docs.splunk.com/Documentation/Splunk/9.0.0/Security/ConfigDSDCAuthEnhancements#Configure_authentication_for_deployment_servers_and_clients). Once enabled, deployment servers can manage only Universal Forwarder versions 9.0 and higher. Though the vulnerability does not directly affect Universal Forwarders, remediation requires updating all Universal Forwarders that the deployment server manages to version 9.0 or higher prior to enabling the remediation.
An unauthenticated attacker with access to the local network of the medical office can query an unprotected Fast Healthcare Interoperability Resources (FHIR) API to get access to sensitive electronic health records (EHR).
An unauthenticated remote attacker can get access without password protection to the affected device. This enables the unprotected read-only access to the stored measurement data.
Free5gc v3.2.1 is vulnerable to Information disclosure.
Lack of authentication in case-exporting components in DDRT Dashcom Live through 2019-05-08 allows anyone to remotely access all claim details by visiting easily guessable exportpdf/all_claim_detail.php?claim_id= URLs.
On Linksys E5350 WiFi Router with firmware version 1.0.00.037 and lower, (and potentially other vendors/devices due to code reuse), the /SysInfo.htm URI does not require a session ID. This web page calls a show_sysinfo function which retrieves WPA passwords, SSIDs, MAC Addresses, serial numbers, WPS Pins, and hardware/firmware versions, and prints this information into the web page. This web page is visible when remote management is enabled. A user who has access to the web interface of the device can extract these secrets. If the device has remote management enabled and is connected directly to the internet, this vulnerability is exploitable over the internet without interaction.
The affected product lacks proper authentication required to query the server on the Ignition 8 Gateway (versions prior to 8.0.10) and Ignition 7 Gateway (versions prior to 7.9.14), allowing an attacker to obtain sensitive information.
Vulnerability in the Oracle WebLogic Server product of Oracle Fusion Middleware (component: Core). Supported versions that are affected are 12.2.1.4.0, 14.1.1.0.0 and 14.1.2.0.0. Easily exploitable vulnerability allows unauthenticated attacker with network access via T3, IIOP to compromise Oracle WebLogic Server. Successful attacks of this vulnerability can result in unauthorized access to critical data or complete access to all Oracle WebLogic Server accessible data. CVSS 3.1 Base Score 7.5 (Confidentiality impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).
An issue was discovered in Chadha PHPKB 9.0 Enterprise Edition. installer/test-connection.php (part of the installation process) allows a remote unauthenticated attacker to disclose local files on hosts running PHP before 7.2.16, or on hosts where the MySQL ALLOW LOCAL DATA INFILE option is enabled.
An issue was discovered in CIPPlanner CIPAce 6.80 Build 2016031401. GetDistributedPOP3 allows attackers to obtain the username and password of the SMTP user.
Zoho ManageEngine OpManager before 125120 allows an unauthenticated user to retrieve an API key via a servlet call.
On IROAD v9 devices, one can Remotely Dump Video Footage and the Live Video Stream. The dashcam exposes endpoints that allow unauthorized users, who gained access through other means, to list and download recorded videos, as well as access live video streams without proper authentication.
An issue was discovered affecting a backup feature where a crafted POST request returns the current configuration of the device in cleartext, including the administrator password. No authentication is required. Affected devices: Wavlink WN575A3, Wavlink WN579G3, Wavlink WN531A6, Wavlink WN535G3, Wavlink WN530H4, Wavlink WN57X93, Wavlink WN572HG3, Wavlink WN575A4, Wavlink WN578A2, Wavlink WN579G3, Wavlink WN579X3, and Jetstream AC3000/ERAC3000
Honeywell equIP and Performance series IP cameras, multiple versions, A vulnerability exists where the affected product allows unauthenticated access to audio streaming over HTTP.
Missing authentication for critical function vulnerability exists in Wi-Fi AP UNIT 'AC-WPS-11ac series'. If exploited, a remote unauthenticated attacker may obtain the product configuration information including authentication information.
An information disclosure vulnerability exists in the OAS Engine SecureBrowseFile functionality of Open Automation Software OAS Platform V16.00.0112. A specially-crafted network request can lead to a disclosure of sensitive information. An attacker can send a network request to trigger this vulnerability.
Motorola FX9500 devices allow remote attackers to read database files.
An issue was discovered on Samsung mobile devices with Q(10.0) software. The DeX Lockscreen allows attackers to access the quick panel and notifications. The Samsung ID is SVE-2019-16532 (March 2020).
An issue was discovered on Mofi Network MOFI4500-4GXeLTE 4.0.8-std devices. Authentication is not required to download the support file that contains sensitive information such as cleartext credentials and password hashes.
Visual Components (owned by KUKA) is a robotic simulator that allows simulating factories and robots in order toimprove planning and decision-making processes. Visual Components software requires a special license which can beobtained from a network license server. The network license server binds to all interfaces (0.0.0.0) and listensfor packets over UDP port 5093. No authentication/authorization is required in order to communicate with theserver. The protocol being used is a property protocol by RMS Sentinel which provides the licensing infrastructurefor the network license server. RMS Sentinel license manager service exposes UDP port 5093 which provides sensitivesystem information that could be leveraged for further exploitation without any kind of authentication. Thisinformation includes detailed hardware and OS characteristics.After a decryption process, a textual protocol is found which contains a simple header with the requested command,application-identifier, and some arguments. The protocol leaks information regarding the receiving serverinformation, license information and managing licenses, among others.Through this flaw, attackers can retreive information about a KUKA simulation system, particularly, the version ofthe licensing server, which is connected to the simulator, and which will allow them to launch local simulationswith similar characteristics, further understanding the dynamics of motion virtualization and opening doors toother attacks (see RVDP#711 and RVDP#712 for subsequent vulnerabilities that compromise integrity andavailability).Beyond compromising simulations, Visual Components provides capabilities to interface with industrial machinery.Particularly, their PLC Connectivity feature 'makes it easy' to connect simulations with control systems usingeither the industry standard OPC UA or other supported vendor specific interfaces. This fills the gap of jumpingfrom simulation to real and enables attackers to pivot from the Visual Components simulator to robots or otherIndustrial Control System (ICS) devices, such as PLCs.
A web application for configuring the controller is accessible at a specific path. It contains an endpoint that allows an unauthenticated remote attacker to read files from the system’s file structure.
An information disclosure vulnerability exists in the OAS Engine SecureTransferFiles functionality of Open Automation Software OAS Platform V16.00.0112. A specially-crafted series of network requests can lead to arbitrary file read. An attacker can send a sequence of requests to trigger this vulnerability.
An issue was discovered on Libre Wireless LS9 LS1.5/p7040 devices. There is a luci_service GETPASS Configuration Password Information Leak. The luci_service daemon running on port 7777 does not require authentication to return the device configuration password in cleartext when using the GETPASS command. As such, any unauthenticated person with access to port 7777 on the device will be able to leak the user's personal device configuration password by issuing the GETPASS command.
Piwigo v12.2.0 was discovered to contain an information leak via the action parameter in /admin/maintenance_actions.php.
TerraMaster NAS 4.2.29 and earlier allows remote attackers to discover the administrative password by sending "User-Agent: TNAS" to module/api.php?mobile/webNasIPS and then reading the PWD field in the response.
There is a Missing Authentication for Critical Function vulnerability in Huawei Smartphone. Successful exploitation of this vulnerability may impair data confidentiality.
Sectona Spectra before 3.4.0 has a vulnerable SOAP API endpoint that leaks sensitive information about the configured assets without proper authentication. This could be used by unauthorized parties to get configured login credentials of the assets via a modified pAccountID value. NOTE: The vendor has indicated this is not a vulnerability and states "This vulnerability occurred due to wrong configuration of system.
A missing authentication check in the WebSocket channel used for the Check Point IoT integration in Nozomi Networks Guardian and CMC, may allow an unauthenticated attacker to obtain assets data without authentication. Malicious unauthenticated users with knowledge on the underlying system may be able to extract limited asset information.
Smartwares HOME easy <=1.0.9 is vulnerable to an unauthenticated database backup download and information disclosure vulnerability. An attacker could disclose sensitive and clear-text information resulting in authentication bypass, session hijacking and full system control.
An issue was discovered in Motorola CX2 router CX 1.0.2 Build 20190508 Rel.97360n where authentication to download the Syslog could be bypassed.
The CACAGOO Cloud Storage Intelligent Camera TV-288ZD-2MP with firmware 3.4.2.0919 allows access to the RTSP service without a password.
Incorrect Access Control in Emerson Smart Wireless Gateway 1420 4.6.59 allows remote attackers to obtain sensitive device information from the administrator console without authentication.
ironic-image is a container image to run OpenStack Ironic as part of Metal³. Prior to version capm3-v1.4.3, if Ironic is not deployed with TLS and it does not have API and Conductor split into separate services, access to the API is not protected by any authentication. Ironic API is also listening in host network. In case the node is not behind a firewall, the API could be accessed by anyone via network without authentication. By default, Ironic API in Metal3 is protected by TLS and basic authentication, so this vulnerability requires operator to configure API without TLS for it to be vulnerable. TLS and authentication however should not be coupled as they are in versions prior to capm3-v1.4.3. A patch exists in versions capm3-v1.4.3 and newer. Some workarounds are available. Either configure TLS for Ironic API (`deploy.sh -t ...`, `IRONIC_TLS_SETUP=true`) or split Ironic API and Conductor via configuration change (old implementation, not recommended). With both workarounds, services are configured with httpd front-end, which has proper authentication configuration in place.
Zoho ManageEngine Desktop Central before 10.0.483 allows unauthenticated users to access PDFGenerationServlet, leading to sensitive information disclosure.