Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in flow computer and remote controller products of ABB ( RMC-100 (Standard), RMC-100-LITE, XIO, XFCG5 , XRCG5 , uFLOG5 , UDC) allows an attacker who successfully exploited this vulnerability could insert and run arbitrary code in an affected system node.
The IRC5 family with UAS service enabled comes by default with credentials that can be found on publicly available manuals. ABB considers this a well documented functionality that helps customer set up however, out of our research, we found multiple production systems running these exact default credentials and consider thereby this an exposure that should be mitigated. Moreover, future deployments should consider that these defaults should be forbidden (user should be forced to change them).
IRC5 exposes an ftp server (port 21). Upon attempting to gain access you are challenged with a request of username and password, however you can input whatever you like. As long as the field isn't empty it will be accepted.
A vulnerability in ABB ARG600 Wireless Gateway series that could allow an attacker to exploit the vulnerability by remotely connecting to the serial port gateway, and/or protocol converter, depending on the configuration.
The web server in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway allows access to different endpoints of the application without authenticating by accessing a specific uniform resource locator (URL) , violating the access-control (ACL) rules. This issue allows obtaining sensitive information that may aid in further attacks and privilege escalation.
In all versions of ABB Power Generation Information Manager (PGIM) and Plant Connect, the affected product is vulnerable to authentication bypass, which may allow an attacker to remotely bypass authentication and extract credentials from the affected device.
Use of Hard-coded Credentials vulnerability in ABB ASPECT-Enterprise, ABB NEXUS Series, ABB MATRIX Series.This issue affects ASPECT-Enterprise: through 3.*; NEXUS Series: through 3.*; MATRIX Series: through 3.*.
A Missing Authentication vulnerability in RobotWare for the OmniCore robot controller allows an attacker to read and modify files on the robot controller if the attacker has access to the Connected Services Gateway Ethernet port.
For ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, confidential data is written in an unprotected file. An attacker who successfully exploited this vulnerability could take full control of the computer.
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, ABB AbilityTM SCADAvantage versions 5.1 to 5.6.5. an XML External Entity Injection vulnerability exists that allows an attacker to read or call arbitrary files from the license server and/or from the network and also block the license handling.
In S+ Operations and S+ History, it is possible that an unauthenticated user could inject values to the Operations History server (or standalone S+ History server) and ultimately write values to the controlled process.
In S+ Operations and S+ Historian, a successful SQL injection exploit can read sensitive data from the database, modify database data (Insert/Update/Delete), execute administration operations on the database (such as shutdown the DBMS), recover the content of a given file present on the DBMS file system and in some cases issue commands to the operating system. This can lead to a loss of confidentiality and data integrity or even affect the product behavior and its availability.
A vulnerability in Base Software for SoftControl allows an attacker to insert and run arbitrary code in a computer running the affected product. This issue affects: .
A S+ Operations and S+ Historian service is subject to a DoS by special crafted messages. An attacker might use this flaw to make it crash or even execute arbitrary code on the machine where the service is hosted.
The affected versions of S+ Operations (version 2.1 SP1 and earlier) used an approach for user authentication which relies on validation at the client node (client-side authentication). This is not as secure as having the server validate a client application before allowing a connection. Therefore, if the network communication or endpoints for these applications are not protected, unauthorized actors can bypass authentication and make unauthorized connections to the server application.
Insecure Storage of Sensitive Information vulnerability in ABB My Control System (on-premise) allows an attacker who successfully exploited this vulnerability to gain access to the secure application data or take control of the application. Of the services that make up the My Control System (on-premise) application, the following ones are affected by this vulnerability: User Interface System Monitoring1 Asset Inventory This issue affects My Control System (on-premise): from 5.0;0 through 5.13.
Improper Privilege Management vulnerability in ABB Ltd. ASPECT®-Enterprise on ASPECT®-Enterprise, Linux (2CQG103201S3021, 2CQG103202S3021, 2CQG103203S3021, 2CQG103204S3021 modules), ABB Ltd. NEXUS Series on NEXUS Series, Linux (2CQG100102R2021, 2CQG100104R2021, 2CQG100105R2021, 2CQG100106R2021, 2CQG100110R2021, 2CQG100112R2021, 2CQG100103R2021, 2CQG100107R2021, 2CQG100108R2021, 2CQG100109R2021, 2CQG100111R2021, 2CQG100113R2021 modules), ABB Ltd. MATRIX Series on MATRIX Series, Linux (2CQG100102R1021, 2CQG100103R1021, 2CQG100104R1021, 2CQG100105R1021, 2CQG100106R1021 modules) allows Privilege Escalation.This issue affects ASPECT®-Enterprise: from 3.0;0 before 3.07.01; NEXUS Series: from 3.0;0 before 3.07.01; MATRIX Series: from 3.0;0 before 3.07.01.
Use of Default Password vulnerability in ABB RCCMD on Windows, Linux, MacOS allows Try Common or Default Usernames and Passwords.This issue affects RCCMD: before 4.40 230207.
Unauthorized file access in WEB Server in ABB ASPECT - Enterprise v3.08.01; NEXUS Series v3.08.01 ; MATRIX Series v3.08.01 allows Attacker to execute arbitrary code remotely
RE11S v1.11 was discovered to contain a command injection vulnerability via the component /goform/formAccept.
A vulnerability was identified in Vaelsys VaelsysV4 up to 5.1.0/5.4.0. Affected by this issue is the function execute_DataObjectProc of the file /grid/vgrid_server.php of the component Web interface. Such manipulation of the argument xajaxargs leads to os command injection. The attack can be executed remotely. The exploit is publicly available and might be used. Upgrading to version 5.1.1 and 5.4.1 can resolve this issue. It is suggested to upgrade the affected component.
There is a system command injection vulnerability in BiSheng-WNM FW 3.0.0.325. A Huawei printer has a system command injection vulnerability. Successful exploitation could lead to remote code execution.
An issue in symphony v.3.6.3 and before allows a remote attacker to execute arbitrary code via the log4j component.
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, EAX20 before 1.0.0.58, EAX80 before 1.0.1.68, EX7500 before 1.0.0.74, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, R6400 before 1.0.1.70, R6400v2 before 1.0.4.118, R6700v3 before 1.0.4.118, R6900P before 1.3.3.140, R7000 before 1.0.11.116, R7000P before 1.3.3.140, R7850 before 1.0.5.68, R7900 before 1.0.4.38, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.68, R8000P before 1.4.2.84, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, XR1000 before 1.0.0.58, and XR300 before 1.0.3.68.
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, EAX20 before 1.0.0.48, EAX80 before 1.0.1.64, EX7500 before 1.0.0.72, R6400 before 1.0.1.68, R6900P before 1.3.2.132, R7000 before 1.0.11.116, R7000P before 1.3.2.132, R7900 before 1.0.4.38, R7960P before 1.4.1.66, R8000 before 1.0.4.66, RAX200 before 1.0.3.106, RS400 before 1.5.1.80, XR300 before 1.0.3.68, MK62 before 1.0.6.110, MR60 before 1.0.6.110, R6400v2 before 1.0.4.106, R8000P before 1.4.1.66, RAX20 before 1.0.2.64, RAX45 before 1.0.2.82, RAX80 before 1.0.3.106, MS60 before 1.0.6.110, R6700v3 before 1.0.4.106, R7900P before 1.4.1.66, RAX15 before 1.0.2.64, RAX50 before 1.0.2.82, RAX75 before 1.0.3.106, RBR750 before 3.2.16.22, RBR850 before 3.2.16.22, RBS750 before 3.2.16.22, RBS850 before 3.2.16.22, RBK752 before 3.2.16.22, and RBK852 before 3.2.16.22.
A command injection vulnerability has been identified in Atos Unify OpenScape 4000 Assistant and Unify OpenScape 4000 Manager (8 before R2.22.18, 10 before 0.28.13, and 10 R1 before R1.34.4) that may allow an unauthenticated attacker to upload arbitrary files and achieve administrative access to the system.
The webserver in Delta DX-3021 versions prior to 1.24 is vulnerable to command injection through the network diagnosis page. This vulnerability could allow a remote unauthenticated user to add files, delete files, and change file permissions.
Nanoleaf Desktop App before v1.3.1 was discovered to contain a command injection vulnerability which is exploited via a crafted HTTP request.
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Apache Software Foundation Apache Airflow Hive Provider.This issue affects Apache Airflow Hive Provider: before 5.0.0.
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.58, R7500v2 before 1.0.3.48, R7800 before 1.0.2.68, R8900 before 1.0.5.2, R9000 before 1.0.5.2, RAX120 before 1.0.1.108, and XR700 before 1.0.1.20.
NETIS SYSTEMS MW5360 V1.0.1.3031 was discovered to contain a command injection vulnerability via the password parameter on the login page.
TOTOLINK_A3700R_V9.1.2u.6165_20211012has a command Injection vulnerability via setOpModeCfg
A weakness has been identified in Totolink A8000RU 7.1cu.643_b20200521. The impacted element is the function setScheduleCfg of the file /cgi-bin/cstecgi.cgi of the component Web Management Interface. Executing a manipulation of the argument mode can lead to os command injection. It is possible to launch the attack remotely. The exploit has been made available to the public and could be used for attacks.
xterm before 375 allows code execution via font ops, e.g., because an OSC 50 response may have Ctrl-g and therefore lead to command execution within the vi line-editing mode of Zsh. NOTE: font ops are not allowed in the xterm default configurations of some Linux distributions.
Diagnosis Controller miss parameter validation, so user may attacked by command injection via HTTP Request.
lib/cmd.js in the node-windows package before 1.0.0-beta.6 for Node.js allows command injection via the PID parameter.
D-Link DIR-3040 device with firmware 120B03 was discovered to contain a command injection vulnerability via the SetTriggerLEDBlink function.
Alarm instance management has command injection when there is a specific command configured. It is only for logged-in users. We recommend you upgrade to version 2.0.6 or higher
A security flaw has been discovered in Totolink A8000RU 7.1cu.643_b20200521. This vulnerability affects the function setWiFiAdvancedCfg of the file /cgi-bin/cstecgi.cgi of the component Web Management Interface. The manipulation of the argument bgProtection results in os command injection. The attack can be launched remotely. The exploit has been released to the public and may be used for attacks.
IP-COM EW9 V15.11.0.14(9732) was discovered to contain a command injection vulnerability in the formSetDebugCfg function.
There is a command injection vulnerability in the ssdpcgi_main function of cgibin binary in D-Link DIR-815 router firmware v1.04.
A command injection vulnerability exists in Jitsi before commit 8aa7be58522f4264078d54752aae5483bfd854b2 when launching browsers on Windows which could allow an attacker to insert an arbitrary URL which opens up the opportunity to remote execution.
A Heap Overflow vulnerability in WLInfoRailService component of Ivanti Avalanche before 6.4.3 allows a remote unauthenticated attacker to execute arbitrary commands
A vulnerability has been found in Teledyne FLIR AX8 up to 1.46.16. Affected by this issue is some unknown functionality of the file palette.php of the component Web Service Handler. The manipulation of the argument palette leads to command injection. The attack is possible to be carried out remotely. The exploit has been disclosed to the public and may be used. Upgrading to version 1.49.16 can resolve this issue. Upgrading the affected component is advised. The vendor points out: "FLIR AX8 internal web site has been refactored to be able to handle the reported vulnerabilities."
A security vulnerability has been detected in Totolink A8000RU 7.1cu.643_b20200521. Affected by this vulnerability is the function setFirewallType of the file /cgi-bin/cstecgi.cgi of the component Web Management Interface. The manipulation of the argument firewallType leads to os command injection. The attack is possible to be carried out remotely. The exploit has been disclosed publicly and may be used.
There is a command injection vulnerability using environment variables in Bitbucket Server and Data Center. An attacker with permission to control their username can exploit this issue to execute arbitrary code on the system. This vulnerability can be unauthenticated if the Bitbucket Server and Data Center instance has enabled “Allow public signup”.
A vulnerability, which was classified as critical, was found in LB-LINK AC1900 Router 1.0.2. Affected is the function websGetVar of the file /goform/set_manpwd. The manipulation of the argument routepwd leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was identified in Totolink A8000RU 7.1cu.643_b20200521. This vulnerability affects the function setPasswordCfg of the file /cgi-bin/cstecgi.cgi of the component Web Management Interface. Such manipulation of the argument admpass leads to os command injection. The attack can be executed remotely. The exploit is publicly available and might be used.
D-Link DIR-823G v1.0.2 was found to contain a command injection vulnerability in the function SetNetworkTomographySettings. This vulnerability allows attackers to execute arbitrary commands via a crafted packet.
An issue was discovered in GTB Central Console 15.17.1-30814.NG. The method systemSettingsDnsDataAction at /opt/webapp/src/AppBundle/Controller/React/SystemSettingsController.php is vulnerable to command injection via the /old/react/v1/api/system/dns/data endpoint. An authenticated attacker can abuse it to inject an arbitrary command and compromise the platform.