For ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, confidential data is written in an unprotected file. An attacker who successfully exploited this vulnerability could take full control of the computer.
Use of Hard-coded Credentials vulnerability in ABB ASPECT-Enterprise, ABB NEXUS Series, ABB MATRIX Series.This issue affects ASPECT-Enterprise: through 3.*; NEXUS Series: through 3.*; MATRIX Series: through 3.*.
A Missing Authentication vulnerability in RobotWare for the OmniCore robot controller allows an attacker to read and modify files on the robot controller if the attacker has access to the Connected Services Gateway Ethernet port.
Due to an issue in configuration, code that was intended for debugging purposes was included in the market release of the ASPECT FW allowing an attacker to bypass authentication. This vulnerability may allow an attacker to change the system time, access files, and make function calls without prior authentication. This issue affects all versions of ASPECT prior to 3.08.04-s01
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, ABB AbilityTM SCADAvantage versions 5.1 to 5.6.5. an XML External Entity Injection vulnerability exists that allows an attacker to read or call arbitrary files from the license server and/or from the network and also block the license handling.
In S+ Operations and S+ Historian, a successful SQL injection exploit can read sensitive data from the database, modify database data (Insert/Update/Delete), execute administration operations on the database (such as shutdown the DBMS), recover the content of a given file present on the DBMS file system and in some cases issue commands to the operating system. This can lead to a loss of confidentiality and data integrity or even affect the product behavior and its availability.
A S+ Operations and S+ Historian service is subject to a DoS by special crafted messages. An attacker might use this flaw to make it crash or even execute arbitrary code on the machine where the service is hosted.
A vulnerability in Base Software for SoftControl allows an attacker to insert and run arbitrary code in a computer running the affected product. This issue affects: .
The affected versions of S+ Operations (version 2.1 SP1 and earlier) used an approach for user authentication which relies on validation at the client node (client-side authentication). This is not as secure as having the server validate a client application before allowing a connection. Therefore, if the network communication or endpoints for these applications are not protected, unauthorized actors can bypass authentication and make unauthorized connections to the server application.
Insecure Storage of Sensitive Information vulnerability in ABB My Control System (on-premise) allows an attacker who successfully exploited this vulnerability to gain access to the secure application data or take control of the application. Of the services that make up the My Control System (on-premise) application, the following ones are affected by this vulnerability: User Interface System Monitoring1 Asset Inventory This issue affects My Control System (on-premise): from 5.0;0 through 5.13.
Improper Privilege Management vulnerability in ABB Ltd. ASPECT®-Enterprise on ASPECT®-Enterprise, Linux (2CQG103201S3021, 2CQG103202S3021, 2CQG103203S3021, 2CQG103204S3021 modules), ABB Ltd. NEXUS Series on NEXUS Series, Linux (2CQG100102R2021, 2CQG100104R2021, 2CQG100105R2021, 2CQG100106R2021, 2CQG100110R2021, 2CQG100112R2021, 2CQG100103R2021, 2CQG100107R2021, 2CQG100108R2021, 2CQG100109R2021, 2CQG100111R2021, 2CQG100113R2021 modules), ABB Ltd. MATRIX Series on MATRIX Series, Linux (2CQG100102R1021, 2CQG100103R1021, 2CQG100104R1021, 2CQG100105R1021, 2CQG100106R1021 modules) allows Privilege Escalation.This issue affects ASPECT®-Enterprise: from 3.0;0 before 3.07.01; NEXUS Series: from 3.0;0 before 3.07.01; MATRIX Series: from 3.0;0 before 3.07.01.
ABB MicroSCADA Pro SYS600 version 9.3 suffers from an instance of CWE-306: Missing Authentication for Critical Function.
Use of Default Password vulnerability in ABB RCCMD on Windows, Linux, MacOS allows Try Common or Default Usernames and Passwords.This issue affects RCCMD: before 4.40 230207.
In all versions of ABB Power Generation Information Manager (PGIM) and Plant Connect, the affected product is vulnerable to authentication bypass, which may allow an attacker to remotely bypass authentication and extract credentials from the affected device.
In S+ Operations and S+ History, it is possible that an unauthenticated user could inject values to the Operations History server (or standalone S+ History server) and ultimately write values to the controlled process.
Improper Input Validation vulnerability in ABB Ltd. ASPECT®-Enterprise on ASPECT®-Enterprise, Linux (2CQG103201S3021, 2CQG103202S3021, 2CQG103203S3021, 2CQG103204S3021 modules), ABB Ltd. NEXUS Series on NEXUS Series, Linux (2CQG100102R2021, 2CQG100104R2021, 2CQG100105R2021, 2CQG100106R2021, 2CQG100110R2021, 2CQG100112R2021, 2CQG100103R2021, 2CQG100107R2021, 2CQG100108R2021, 2CQG100109R2021, 2CQG100111R2021, 2CQG100113R2021 modules), ABB Ltd. MATRIX Series on MATRIX Series, Linux (2CQG100102R1021, 2CQG100103R1021, 2CQG100104R1021, 2CQG100105R1021, 2CQG100106R1021 modules) allows Command Injection.This issue affects ASPECT®-Enterprise: from 3.0;0 before 3.07.0; NEXUS Series: from 3.0;0 before 3.07.0; MATRIX Series: from 3.0;0 before 3.07.1.
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in flow computer and remote controller products of ABB ( RMC-100 (Standard), RMC-100-LITE, XIO, XFCG5 , XRCG5 , uFLOG5 , UDC) allows an attacker who successfully exploited this vulnerability could insert and run arbitrary code in an affected system node.
IRC5 exposes an ftp server (port 21). Upon attempting to gain access you are challenged with a request of username and password, however you can input whatever you like. As long as the field isn't empty it will be accepted.
Pluto Safety PLC Gateway Ethernet devices ABB GATE-E1 and GATE-E2 all versions do not allow authentication to be configured on administrative telnet or web interfaces, which could enable various effects vectors, including conducting device resets, reading or modifying registers, and changing configuration settings such as IP addresses.
In ABB IP GATEWAY 3.39 and prior, by accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to access the configuration files and application pages without authentication.
A vulnerability in ABB ARG600 Wireless Gateway series that could allow an attacker to exploit the vulnerability by remotely connecting to the serial port gateway, and/or protocol converter, depending on the configuration.
The web server in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway allows access to different endpoints of the application without authenticating by accessing a specific uniform resource locator (URL) , violating the access-control (ACL) rules. This issue allows obtaining sensitive information that may aid in further attacks and privilege escalation.
Unauthorized file access in WEB Server in ABB ASPECT - Enterprise v3.08.01; NEXUS Series v3.08.01 ; MATRIX Series v3.08.01 allows Attacker to execute arbitrary code remotely
In ABB IP GATEWAY 3.39 and prior, some configuration files contain passwords stored in plain-text, which may allow an attacker to gain unauthorized access.
The Redis data structure component used in ABB eSOMS versions 6.0 to 6.0.2 stores credentials in clear text. If an attacker has file system access, this can potentially compromise the credentials' confidentiality.
In S+ Operations and S+ Historian, the passwords of internal users (not Windows Users) are encrypted but improperly stored in a database.
Storing Passwords in a Recoverable Format vulnerability in ABB Zenon 8.20 allows an attacker who successfully exploit the vulnerability may add more network clients that may monitor various activities of the Zenon.
The backup function in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway saves the current settings and configuration of the application, including credentials of existing user accounts and other configuration's credentials in plaintext.
Storing Passwords in a Recoverable Format vulnerability in ABB Zenon 8.20 allows an attacker who successfully exploit the vulnerability may add or alter data points and corresponding attributes. Once such engineering data is used the data visualization will be altered for the end user.
Username Enumeration vulnerabilities allow access to application level username add, delete, modify and list functions. Affected products: ABB ASPECT - Enterprise v3.08.02; NEXUS Series v3.08.02; MATRIX Series v3.08.02
Credentials Disclosure vulnerabilities allow access to on board project back-up bundles. Affected products: ABB ASPECT - Enterprise v3.08.02; NEXUS Series v3.08.02; MATRIX Series v3.08.02
LemonLDAP::NG -2.0.3 has Incorrect Access Control.
Kaseya VSA before 9.5.7 allows credential disclosure, as exploited in the wild in July 2021. By default Kaseya VSA on premise offers a download page where the clients for the installation can be downloaded. The default URL for this page is https://x.x.x.x/dl.asp When an attacker download a client for Windows and installs it, the file KaseyaD.ini is generated (C:\Program Files (x86)\Kaseya\XXXXXXXXXX\KaseyaD.ini) which contains an Agent_Guid and AgentPassword This Agent_Guid and AgentPassword can be used to log in on dl.asp (https://x.x.x.x/dl.asp?un=840997037507813&pw=113cc622839a4077a84837485ced6b93e440bf66d44057713cb2f95e503a06d9) This request authenticates the client and returns a sessionId cookie that can be used in subsequent attacks to bypass authentication. Security issues discovered --- * Unauthenticated download page leaks credentials * Credentials of agent software can be used to obtain a sessionId (cookie) that can be used for services not intended for use by agents * dl.asp accepts credentials via a GET request * Access to KaseyaD.ini gives an attacker access to sufficient information to penetrate the Kaseya installation and its clients. Impact --- Via the page /dl.asp enough information can be obtained to give an attacker a sessionId that can be used to execute further (semi-authenticated) attacks against the system.
The manage users profile services of the network camera device allows an authenticated. Remote attackers can modify URL parameters and further amend user’s information and escalate privileges to control the devices.
The sensitive information of webcam device is not properly protected. Remote attackers can unauthentically grant administrator’s credential and further control the devices.
An issue was discovered in Fresenius Kabi PharmaHelp 5.1.759.0 allows attackers to gain escalated privileges via via capture of user login information.
The Vangene deltaFlow E-platform does not take properly protective measures. Attackers can obtain privileged permissions remotely by tampering with users’ data in the Cookie.
An isssue in GatesAIr Flexiva FM Transmitter/Exiter Fax 150W allows a remote attacker to gain privileges via the LDAP and SMTP credentials.
Realtek xPON RTL9601D SDK 1.9 stores passwords in plaintext which may allow attackers to possibly gain access to the device with root permissions via the build-in network monitoring tool and execute arbitrary commands.
Tomcat application credentials are hardcoded in SonicWall GMS and Analytics configuration file. This issue affects GMS: 9.3.2-SP1 and earlier versions; Analytics: 2.5.0.4-R7 and earlier versions.
Pre Classified Listing PHP allows remote attackers to bypass authentication and gain administrative access by setting the (1) adminname and the (2) adminid cookies to "admin".
RustFS is a distributed object storage system built in Rust. In versions 1.0.0-alpha.13 through 1.0.0-alpha.78, a flawed `deny_only` short-circuit in RustFS IAM allows a restricted service account or STS credential to self-issue an unrestricted service account, inheriting the parent’s full privileges. This enables privilege escalation and bypass of session/inline policy restrictions. Version 1.0.0-alpha.79 fixes the issue.
The web application on Agilia Link+ version 3.0 implements authentication and session management mechanisms exclusively on the client-side and does not protect authentication attributes sufficiently.
Rockwell Automation Studio 5000 Logix Designer Versions 21 and later, and RSLogix 5000 Versions 16 through 20 use a key to verify Logix controllers are communicating with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. Rockwell Automation Studio 5000 Logix Designer Versions 21 and later and RSLogix 5000: Versions 16 through 20 are vulnerable because an unauthenticated attacker could bypass this verification mechanism and authenticate with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800.
An unprotected ssh private key exists on the Gryphon devices which could be used to achieve root access to a server affiliated with Gryphon's development and infrastructure. At the time of discovery, the ssh key could be used to login to the development server hosted in Amazon Web Services.
KMS Controls BAC-A1616BC BACnet devices have a cleartext password of snowman in the BACKDOOR_NAME variable in the BC_Logon.swf file.
It is possible to unmask credentials and other sensitive information on “unprotected” project files, which may allow an attacker to remotely access the C-More Touch Panels EA9 series: firmware versions prior to 6.53 and manipulate system configurations.
In ApexPro Telemetry Server, Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Telemetry Server Version 4.3, CARESCAPE Central Station (CSCS) Versions 1.X, a vulnerability exists in the affected products that could allow an attacker to obtain access to the SSH private key in configuration files.
E3 Site Supervisor (firmware version < 2.31F01) has a default admin user "ONEDAY" with a daily generated password. An attacker can predictably generate the password for ONEDAY. The oneday user cannot be deleted or modified by any user.
Status2k does not remove the install directory allowing credential reset.