Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list and bindnum at /goform/SetIpMacBind.
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter schedStartTime and schedEndTime at /goform/openSchedWifi.
Tenda AX1806 v1.0.0.1 contains a stack overflow via the iptv.stb.port parameter in the function formGetIptv.
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter macFilterType and parameter deviceList at url /goform/setMacFilterCfg.
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list at /goform/SetVirtualServerCfg.
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter macFilterType and parameter deviceList at /goform/setMacFilterCfg.
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function 'formWifiBasicSet.'
Stack Overflow vulnerability in Tenda AX1803 v.1.0.0.1 allows a remote attacker to execute arbitrary code via the devName parameter in the function formAddMacfilterRule.
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter firewallEn at /goform/SetFirewallCfg.
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list at /goform/SetNetControlList.
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter list and bindnum at /goform/SetIpMacBind.
Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42_multi were discovered to contain a tack overflow via the list parameter in the formSetQosBand function.
Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function.
Tenda F1202 V1.2.0.9, PA202 V1.1.2.5, PW201A V1.1.2.5 and FH1202 V1.2.0.9 were discovered to contain a stack overflow via the page parameter in the SafeEmailFilter function.
Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function.
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and FH1203 V2.0.1.6 were discovered to contain a stack overflow via the list parameter in the setaccount function.
Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function.
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function.
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function.
Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) was discovered to contain a stack overflow via the deviceId parameter in the formSetDeviceName function.
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the entrys parameter in the fromAddressNat function.
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function.
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function.
Tenda AC1206 V15.03.06.23, F1202 V1.2.0.20(408), and FH1202 V1.2.0.20(408) were discovered to contain a stack overflow in the page parameter in the fromSetIpBind function.
Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function frmL7ProtForm.
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the page parameter in the fromAddressNat function.
Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromNatStaticSetting.
Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromSafeMacFilter.
Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromSafeClientFilter.
Tenda AC1206 V15.03.06.23 and AC10 V15.03.06.47 were discovered to contain a stack overflow in the deviceId parameter in the saveParentControlInfo function.
Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromDhcpListClient.
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function.
Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromqossetting.
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the deviceId parameter in the formSetDeviceName function.
Tenda TX3 US_TX3V1.0br_V16.03.13.11_multi_TDE01 was discovered to contain a stack overflow via the startIp parameter at /goform/SetPptpServerCfg.
Tenda i21 V1.0.0.14(4656) is vulnerable to Buffer Overflow via /goform/setDiagnoseInfo.
Tenda i21 V1.0.0.14(4656) has a stack overflow vulnerability via /goform/setSysPwd.
Tenda TX3 US_TX3V1.0br_V16.03.13.11_multi_TDE01 was discovered to contain a stack overflow via the time parameter at /goform/SetSysTimeCfg.
Tenda i21 V1.0.0.14(4656) is vulnerable to Buffer Overflow via /goform/setUplinkInfo.
Tenda i21 V1.0.0.14(4656) is vulnerable to Buffer Overflow via /goform/setSnmpInfo.
Tenda AC23 V16.03.07.45_cn was discovered to contain a stack overflow via the shareSpeed parameter in the fromSetWifiGusetBasic function.
Tenda AC23 V16.03.07.45_cn was discovered to contain a stack overflow via the time parameter in the setSmartPowerManagement function.
Tenda AC23 V16.03.07.45_cn was discovered to contain a stack overflow via the schedStartTime parameter in the setSchedWifi function.
Tenda AC18 V15.03.05.19(6318) was discovered to contain a stack overflow via the time parameter in the fromSetSysTime function.
Tenda i21 V1.0.0.14(4656) is vulnerable to Buffer Overflow via /goform/AddSysLogRule.
Tenda TX3 US_TX3V1.0br_V16.03.13.11_multi_TDE01 was discovered to contain a stack overflow via the timeZone parameter at /goform/SetSysTimeCfg.
Tenda TX3 US_TX3V1.0br_V16.03.13.11_multi_TDE01 was discovered to contain a stack overflow via the firewallEn parameter at /goform/SetFirewallCfg.
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter time at /goform/saveParentControlInfo.
Tenda TX3 US_TX3V1.0br_V16.03.13.11_multi_TDE01 was discovered to contain a stack overflow via the list parameter at /goform/SetVirtualServerCfg.
Tenda AC23 V16.03.07.45_cn was discovered to contain a stack overflow via the wpapsk_crypto parameter in the fromSetWirelessRepeat function.