Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2023-26297

Summary
Assigner-hp
Assigner Org ID-74586083-13ce-40fd-b46a-8e5d23cfbcb2
Published At-12 Jun, 2023 | 21:19
Updated At-06 Jan, 2025 | 15:50
Rejected At-
Credits

Previous versions of HP Device Manager (prior to HPDM 5.0.10) could potentially allow command injection and/or elevation of privileges.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:hp
Assigner Org ID:74586083-13ce-40fd-b46a-8e5d23cfbcb2
Published At:12 Jun, 2023 | 21:19
Updated At:06 Jan, 2025 | 15:50
Rejected At:
▼CVE Numbering Authority (CNA)

Previous versions of HP Device Manager (prior to HPDM 5.0.10) could potentially allow command injection and/or elevation of privileges.

Affected Products
Vendor
HP Inc.HP Inc.
Product
HP Device Manager
Versions
Affected
  • 5.0.9
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://support.hp.com/us-en/document/ish_7974907-7974931-16/hpsbhf03842
N/A
Hyperlink: https://support.hp.com/us-en/document/ish_7974907-7974931-16/hpsbhf03842
Resource: N/A
▼Authorized Data Publishers (ADP)
1. CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://support.hp.com/us-en/document/ish_7974907-7974931-16/hpsbhf03842
x_transferred
Hyperlink: https://support.hp.com/us-en/document/ish_7974907-7974931-16/hpsbhf03842
Resource:
x_transferred
2. CISA ADP Vulnrichment
Affected Products
Problem Types
TypeCWE IDDescription
CWECWE-77CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection')
Type: CWE
CWE ID: CWE-77
Description: CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection')
Metrics
VersionBase scoreBase severityVector
3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:hp-security-alert@hp.com
Published At:12 Jun, 2023 | 22:15
Updated At:06 Jan, 2025 | 16:15

Previous versions of HP Device Manager (prior to HPDM 5.0.10) could potentially allow command injection and/or elevation of privileges.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Secondary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Secondary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
CPE Matches

HP Inc.
hp
>>hp_device_manager>>5.0
cpe:2.3:a:hp:hp_device_manager:5.0:-:*:*:*:*:*:*
HP Inc.
hp
>>hp_device_manager>>5.0
cpe:2.3:a:hp:hp_device_manager:5.0:sp1:*:*:*:*:*:*
HP Inc.
hp
>>hp_device_manager>>5.0
cpe:2.3:a:hp:hp_device_manager:5.0:sp2:*:*:*:*:*:*
HP Inc.
hp
>>hp_device_manager>>5.0.3
cpe:2.3:a:hp:hp_device_manager:5.0.3:*:*:*:*:*:*:*
HP Inc.
hp
>>hp_device_manager>>5.0.4
cpe:2.3:a:hp:hp_device_manager:5.0.4:*:*:*:*:*:*:*
HP Inc.
hp
>>hp_device_manager>>5.0.5
cpe:2.3:a:hp:hp_device_manager:5.0.5:*:*:*:*:*:*:*
HP Inc.
hp
>>hp_device_manager>>5.0.6
cpe:2.3:a:hp:hp_device_manager:5.0.6:*:*:*:*:*:*:*
HP Inc.
hp
>>hp_device_manager>>5.0.7
cpe:2.3:a:hp:hp_device_manager:5.0.7:*:*:*:*:*:*:*
HP Inc.
hp
>>hp_device_manager>>5.0.7.1
cpe:2.3:a:hp:hp_device_manager:5.0.7.1:*:*:*:*:*:*:*
HP Inc.
hp
>>hp_device_manager>>5.0.8
cpe:2.3:a:hp:hp_device_manager:5.0.8:*:*:*:*:*:*:*
HP Inc.
hp
>>hp_device_manager>>5.0.9
cpe:2.3:a:hp:hp_device_manager:5.0.9:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-77Primarynvd@nist.gov
CWE-77Secondary134c704f-9b21-4f2e-91b3-4a467353bcc0
CWE ID: CWE-77
Type: Primary
Source: nvd@nist.gov
CWE ID: CWE-77
Type: Secondary
Source: 134c704f-9b21-4f2e-91b3-4a467353bcc0
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://support.hp.com/us-en/document/ish_7974907-7974931-16/hpsbhf03842hp-security-alert@hp.com
Vendor Advisory
https://support.hp.com/us-en/document/ish_7974907-7974931-16/hpsbhf03842af854a3a-2127-422b-91ae-364da2661108
Vendor Advisory
Hyperlink: https://support.hp.com/us-en/document/ish_7974907-7974931-16/hpsbhf03842
Source: hp-security-alert@hp.com
Resource:
Vendor Advisory
Hyperlink: https://support.hp.com/us-en/document/ish_7974907-7974931-16/hpsbhf03842
Source: af854a3a-2127-422b-91ae-364da2661108
Resource:
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

522Records found

CVE-2026-0779
Matching Score-4
Assigner-Zero Day Initiative
ShareView Details
Matching Score-4
Assigner-Zero Day Initiative
CVSS Score-7.2||HIGH
EPSS-0.19% / 40.64%
||
7 Day CHG+0.02%
Published-23 Jan, 2026 | 02:57
Updated-18 Feb, 2026 | 19:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
ALGO 8180 IP Audio Alerter Ping Command Injection Remote Code Execution Vulnerability

ALGO 8180 IP Audio Alerter Ping Command Injection Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of ALGO 8180 IP Audio Alerter devices. Authentication is required to exploit this vulnerability. The specific flaw exists within the web-based user interface. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-25568.

Action-Not Available
Vendor-algosolutionsALGO
Product-8180_ip_audio_alerter_firmware8180_ip_audio_alerter8180 IP Audio Alerter
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2026-1625
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.02% / 3.73%
||
7 Day CHG~0.00%
Published-29 Jan, 2026 | 22:02
Updated-23 Feb, 2026 | 09:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DWR-M961 SMS Message formSmsManage sub_4250E0 command injection

A vulnerability was detected in D-Link DWR-M961 1.1.47. The impacted element is the function sub_4250E0 of the file /boafrm/formSmsManage of the component SMS Message. Performing a manipulation of the argument action_value results in command injection. The attack may be initiated remotely. The exploit is now public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dwr-m961dwr-m961_firmwareDWR-M961
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-1327
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.69% / 71.38%
||
7 Day CHG+0.13%
Published-22 Jan, 2026 | 14:02
Updated-23 Feb, 2026 | 08:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Totolink NR1800X POST Request cstecgi.cgi setTracerouteCfg command injection

A security vulnerability has been detected in Totolink NR1800X 9.1.0u.6279_B20210910. This issue affects the function setTracerouteCfg of the file /cgi-bin/cstecgi.cgi of the component POST Request Handler. Such manipulation of the argument command leads to command injection. The attack can be launched remotely. The exploit has been disclosed publicly and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-nr1800x_firmwarenr1800xNR1800X
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-8821
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.24% / 46.48%
||
7 Day CHG~0.00%
Published-11 Aug, 2025 | 00:02
Updated-04 Sep, 2025 | 18:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 RP_setBasic os command injection

A vulnerability was identified in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. This issue affects the function RP_setBasic of the file /goform/RP_setBasic. The manipulation of the argument bssid leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6350_firmwarere6300_firmwarere6500re9000re9000_firmwarere6350re6250re6300re6250_firmwarere7000_firmwarere6500_firmwarere7000RE6300RE6350RE7000RE9000RE6500RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-51301
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.13% / 33.05%
||
7 Day CHG~0.00%
Published-30 Oct, 2024 | 00:00
Updated-10 Apr, 2025 | 15:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Draytek Vigor3900 1.5.1.3, attackers can inject malicious commands into mainfunction.cgi and execute arbitrary commands by calling the packet_monitor function.

Action-Not Available
Vendor-n/aDrayTek Corp.
Product-vigor3900_firmwarevigor3900n/avigor3900_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-9584
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.18% / 38.94%
||
7 Day CHG~0.00%
Published-Not Available
Updated-02 Oct, 2025 | 19:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability was found in Comfast CF-N1 2.6.0. Affected by this issue is the function update_interface_png of the file /usr/bin/webmgnt. The manipulation of the argument interface/display_name results in command injection. The attack can be executed remotely. The exploit has been made public and could be used.

Action-Not Available
Vendor-comfast
Product-cf-n1_firmwarecf-n1
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-9223
Matching Score-4
Assigner-Zohocorp
ShareView Details
Matching Score-4
Assigner-Zohocorp
CVSS Score-8.8||HIGH
EPSS-1.28% / 79.30%
||
7 Day CHG-0.13%
Published-11 Nov, 2025 | 13:13
Updated-26 Feb, 2026 | 16:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Command Injection

Zohocorp ManageEngine Applications Manager versions 178100 and below are vulnerable to authenticated command injection vulnerability due to the improper configuration in the execute program action feature.

Action-Not Available
Vendor-Zoho Corporation Pvt. Ltd.
Product-ManageEngine Applications Manager
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-9579
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.20% / 42.40%
||
7 Day CHG~0.00%
Published-28 Aug, 2025 | 18:32
Updated-11 Sep, 2025 | 13:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
LB-LINK BL-X26 HTTP set_hidessid_cfg os command injection

A weakness has been identified in LB-LINK BL-X26 1.2.8. The impacted element is an unknown function of the file /goform/set_hidessid_cfg of the component HTTP Handler. This manipulation of the argument enable causes os command injection. The attack can be initiated remotely. The exploit has been made available to the public and could be exploited. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-b-linkLB-LINK
Product-bl-x26bl-x26_firmwareBL-X26
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-9161
Matching Score-4
Assigner-Rockwell Automation
ShareView Details
Matching Score-4
Assigner-Rockwell Automation
CVSS Score-7.3||HIGH
EPSS-0.08% / 23.04%
||
7 Day CHG~0.00%
Published-09 Sep, 2025 | 12:57
Updated-20 Oct, 2025 | 19:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Rockwell Automation FactoryTalk Optix Remote Code Execution Vulnerability

A security issue exists within FactoryTalk Optix MQTT broker due to the lack of URI sanitization. This flaw enables the loading of remote Mosquito plugins, which can be used to achieve remote code execution.

Action-Not Available
Vendor-Rockwell Automation, Inc.
Product-factorytalk_optixFactoryTalk Optix
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-51299
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.13% / 33.05%
||
7 Day CHG~0.00%
Published-30 Oct, 2024 | 00:00
Updated-10 Apr, 2025 | 15:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Draytek Vigor3900 1.5.1.3, attackers can inject malicious commands into mainfunction.cgi and execute arbitrary commands by calling the dumpSyslog function.

Action-Not Available
Vendor-n/aDrayTek Corp.
Product-vigor3900_firmwarevigor3900n/avigor3900_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-9586
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.18% / 38.94%
||
7 Day CHG~0.00%
Published-28 Aug, 2025 | 21:02
Updated-02 Oct, 2025 | 19:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Comfast CF-N1 webmgnt wireless_device_dissoc command injection

A vulnerability was identified in Comfast CF-N1 2.6.0. This vulnerability affects the function wireless_device_dissoc of the file /usr/bin/webmgnt. Such manipulation of the argument mac leads to command injection. The attack may be performed from a remote location. The exploit is publicly available and might be used.

Action-Not Available
Vendor-comfastComfast
Product-cf-n1_firmwarecf-n1CF-N1
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-9583
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.18% / 38.94%
||
7 Day CHG~0.00%
Published-28 Aug, 2025 | 20:02
Updated-02 Oct, 2025 | 19:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Comfast CF-N1 webmgnt ping_config command injection

A vulnerability has been found in Comfast CF-N1 2.6.0. Affected by this vulnerability is the function ping_config of the file /usr/bin/webmgnt. The manipulation leads to command injection. Remote exploitation of the attack is possible. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-comfastComfast
Product-cf-n1_firmwarecf-n1CF-N1
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-9580
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.20% / 42.40%
||
7 Day CHG~0.00%
Published-28 Aug, 2025 | 19:02
Updated-12 Sep, 2025 | 16:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
LB-LINK BL-X26 HTTP set_blacklist os command injection

A security vulnerability has been detected in LB-LINK BL-X26 1.2.8. This affects an unknown function of the file /goform/set_blacklist of the component HTTP Handler. Such manipulation of the argument mac leads to os command injection. The attack can be launched remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-lb-linkLB-LINK
Product-bl-x26bl-x26_firmwareBL-X26
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-8830
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.24% / 46.48%
||
7 Day CHG~0.00%
Published-11 Aug, 2025 | 04:32
Updated-04 Sep, 2025 | 18:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 setWan sub_3517C os command injection

A vulnerability has been found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. Affected by this issue is the function sub_3517C of the file /goform/setWan. The manipulation of the argument Hostname leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6350_firmwarere6300_firmwarere6500re9000re9000_firmwarere6350re6250re6300re6250_firmwarere7000_firmwarere6500_firmwarere7000RE6300RE6350RE6250RE7000RE6500RE9000
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-8829
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.24% / 46.48%
||
7 Day CHG~0.00%
Published-11 Aug, 2025 | 04:02
Updated-04 Sep, 2025 | 18:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 RP_setBasicAuto um_red os command injection

A vulnerability was identified in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. Affected by this vulnerability is the function um_red of the file /goform/RP_setBasicAuto. The manipulation of the argument hname leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6350_firmwarere6300_firmwarere6500re9000re9000_firmwarere6350re6250re6300re6250_firmwarere7000_firmwarere6500_firmwarere7000RE6300RE6350RE7000RE9000RE6500RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-8825
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.24% / 46.48%
||
7 Day CHG~0.00%
Published-11 Aug, 2025 | 02:02
Updated-04 Sep, 2025 | 18:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 RP_setBasicAuto os command injection

A vulnerability was identified in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. This affects the function RP_setBasicAuto of the file /goform/RP_setBasicAuto. The manipulation of the argument staticIp/staticNetmask leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6350_firmwarere6300_firmwarere6500re9000re9000_firmwarere6350re6250re6300re6250_firmwarere7000_firmwarere6500_firmwarere7000RE6300RE6350RE7000RE9000RE6500RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-8937
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.54% / 67.31%
||
7 Day CHG~0.00%
Published-14 Aug, 2025 | 04:32
Updated-03 Oct, 2025 | 18:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK N350R formSysCmd command injection

A vulnerability has been found in TOTOLINK N350R 1.2.3-B20130826. This vulnerability affects unknown code of the file /boafrm/formSysCmd. The manipulation leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-n350r_firmwaren350rN350R
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-8827
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.24% / 46.48%
||
7 Day CHG~0.00%
Published-11 Aug, 2025 | 03:02
Updated-04 Sep, 2025 | 18:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 RP_setBasicAuto um_inspect_cross_band os command injection

A vulnerability was found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. This issue affects the function um_inspect_cross_band of the file /goform/RP_setBasicAuto. The manipulation of the argument staticGateway leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6350_firmwarere6300_firmwarere6500re9000re9000_firmwarere6350re6250re6300re6250_firmwarere7000_firmwarere6500_firmwarere7000RE6300RE6350RE7000RE9000RE6500RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-8956
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.07% / 22.30%
||
7 Day CHG~0.00%
Published-14 Aug, 2025 | 10:02
Updated-18 Aug, 2025 | 15:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR‑818L ssdpcgi cgibin getenv command injection

A vulnerability was found in D-Link DIR‑818L up to 1.05B01. This issue affects the function getenv of the file /htdocs/cgibin of the component ssdpcgi. The manipulation leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-818l_firmwaredir-818lDIR‑818L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-9585
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.18% / 38.94%
||
7 Day CHG~0.00%
Published-28 Aug, 2025 | 20:32
Updated-02 Oct, 2025 | 19:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Comfast CF-N1 webmgnt wifilith_delete_pic_file command injection

A vulnerability was determined in Comfast CF-N1 2.6.0. This affects the function wifilith_delete_pic_file of the file /usr/bin/webmgnt. This manipulation of the argument portal_delete_picname causes command injection. The attack is possible to be carried out remotely. The exploit has been publicly disclosed and may be utilized.

Action-Not Available
Vendor-comfastComfast
Product-cf-n1_firmwarecf-n1CF-N1
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-7932
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.08% / 23.67%
||
7 Day CHG-0.01%
Published-21 Jul, 2025 | 17:02
Updated-03 Oct, 2025 | 18:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR‑817L ssdpcgi lxmldbc_system command injection

A vulnerability classified as critical has been found in D-Link DIR‑817L up to 1.04B01. This affects the function lxmldbc_system of the file ssdpcgi. The manipulation leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-817ldir-817l_firmwareDIR‑817L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-7836
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.08% / 23.67%
||
7 Day CHG-0.01%
Published-19 Jul, 2025 | 16:44
Updated-03 Oct, 2025 | 18:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-816L Environment Variable cgibin lxmldbc_system command injection

A vulnerability has been found in D-Link DIR-816L up to 2.06B01 and classified as critical. Affected by this vulnerability is the function lxmldbc_system of the file /htdocs/cgibin of the component Environment Variable Handler. The manipulation leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-816l_firmwaredir-816lDIR-816L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-11285
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.41% / 61.11%
||
7 Day CHG~0.00%
Published-05 Oct, 2025 | 06:02
Updated-09 Oct, 2025 | 17:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
samanhappy MCPHub serverController.ts os command injection

A vulnerability was found in samanhappy MCPHub up to 0.9.10. Affected by this issue is some unknown functionality of the file src/controllers/serverController.ts. The manipulation of the argument command/args results in os command injection. The attack can be launched remotely. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-mcphubxsamanhappy
Product-mcphubMCPHub
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-7952
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.66% / 81.78%
||
7 Day CHG-0.12%
Published-22 Jul, 2025 | 03:02
Updated-23 Jul, 2025 | 16:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK T6 MQTT Packet wireless.so ckeckKeepAlive command injection

A vulnerability classified as critical was found in TOTOLINK T6 4.1.5cu.748. This vulnerability affects the function ckeckKeepAlive of the file wireless.so of the component MQTT Packet Handler. The manipulation leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-t6_firmwaret6T6
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-2991
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-4.59% / 89.01%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 18:31
Updated-22 Jan, 2025 | 17:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1203 WriteFacMac formWriteFacMac command injection

A vulnerability has been found in Tenda FH1203 2.0.1.6 and classified as critical. This vulnerability affects the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258160. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1203_firmwarefh1203FH1203fh1203_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-51300
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.13% / 33.05%
||
7 Day CHG~0.00%
Published-30 Oct, 2024 | 00:00
Updated-10 Apr, 2025 | 15:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Draytek Vigor3900 1.5.1.3, attackers can inject malicious commands into mainfunction.cgi and execute arbitrary commands by calling the get_rrd function.

Action-Not Available
Vendor-n/aDrayTek Corp.
Product-vigor3900_firmwarevigor3900n/avigor3900_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2020-8188
Matching Score-4
Assigner-HackerOne
ShareView Details
Matching Score-4
Assigner-HackerOne
CVSS Score-8.8||HIGH
EPSS-0.94% / 75.99%
||
7 Day CHG~0.00%
Published-02 Jul, 2020 | 18:35
Updated-04 Aug, 2024 | 09:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

We have recently released new version of UniFi Protect firmware v1.13.3 and v1.14.10 for Unifi Cloud Key Gen2 Plus and UniFi Dream Machine Pro/UNVR respectively that fixes vulnerabilities found on Protect firmware v1.13.2, v1.14.9 and prior according to the description below:View only users can run certain custom commands which allows them to assign themselves unauthorized roles and escalate their privileges.

Action-Not Available
Vendor-n/aUbiquiti Inc.
Product-unifi_protect_firmwareunifi_protectunifi_dream_machine_prounifi_cloud_key_plusProtect for UniFi Cloud Key Gen2 Plus, UniFi Dream Machine Pro, UNVR
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-8233
Matching Score-4
Assigner-HackerOne
ShareView Details
Matching Score-4
Assigner-HackerOne
CVSS Score-8.8||HIGH
EPSS-14.94% / 94.42%
||
7 Day CHG~0.00%
Published-17 Aug, 2020 | 15:41
Updated-04 Aug, 2024 | 09:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A command injection vulnerability exists in EdgeSwitch firmware <v1.9.0 that allowed an authenticated read-only user to execute arbitrary shell commands over the HTTP interface, allowing them to escalate privileges.

Action-Not Available
Vendor-n/aopenSUSEUbiquiti Inc.
Product-es-24-250wep-16-xges-48-liteedgeswitch_firmwareep-s16es-24-500wes-8-150wes-24-litees-16-150wleapbackports_slees-48-750wes-48-500wes-12fEdgeSwitch firmware v1.9.0 and prior
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-51304
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.18% / 39.74%
||
7 Day CHG~0.00%
Published-30 Oct, 2024 | 00:00
Updated-10 Apr, 2025 | 15:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Draytek Vigor3900 1.5.1.3, attackers can inject malicious commands into mainfunction.cgi and execute arbitrary commands by calling the ldap_search_dn function.

Action-Not Available
Vendor-n/aDrayTek Corp.
Product-vigor3900_firmwarevigor3900n/avigor3900_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-30213
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-6.67% / 91.04%
||
7 Day CHG~0.00%
Published-12 Jul, 2024 | 00:00
Updated-02 Aug, 2024 | 01:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

StoneFly Storage Concentrator (SC and SCVM) before 8.0.4.26 allows remote authenticated users to achieve Command Injection via a Ping URL, leading to remote code execution.

Action-Not Available
Vendor-n/astonefly
Product-n/ascvm
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-8244
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.93% / 75.77%
||
7 Day CHG~0.00%
Published-27 Jul, 2025 | 22:02
Updated-29 Jul, 2025 | 21:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK X15 HTTP POST Request formMapDelDevice buffer overflow

A vulnerability was found in TOTOLINK X15 1.0.0-B20230714.1105. It has been classified as critical. Affected is an unknown function of the file /boafrm/formMapDelDevice of the component HTTP POST Request Handler. The manipulation of the argument macstr leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-x15_firmwarex15X15
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-7788
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.17% / 38.29%
||
7 Day CHG~0.00%
Published-18 Jul, 2025 | 15:02
Updated-11 Sep, 2025 | 19:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Xuxueli xxl-job SampleXxlJob.java commandJobHandler os command injection

A vulnerability has been found in Xuxueli xxl-job up to 3.1.1 and classified as critical. Affected by this vulnerability is the function commandJobHandler of the file src\main\java\com\xxl\job\executor\service\jobhandler\SampleXxlJob.java. The manipulation leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-xuxueliXuxueli
Product-xxl-jobxxl-job
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-7407
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.70% / 71.78%
||
7 Day CHG+0.30%
Published-10 Jul, 2025 | 13:32
Updated-16 Jul, 2025 | 16:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Netgear D6400 diag.cgi os command injection

A vulnerability, which was classified as critical, was found in Netgear D6400 1.0.0.114. This affects an unknown part of the file diag.cgi. The manipulation of the argument host_name leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early and confirmed the existence of the vulnerability. They reacted very quickly, professional and kind. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-NETGEAR, Inc.
Product-d6400d6400_firmwareD6400
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-7415
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.57% / 68.35%
||
7 Day CHG+0.24%
Published-10 Jul, 2025 | 21:02
Updated-16 Jul, 2025 | 15:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O3V2 httpd getTraceroute fromTraceroutGet command injection

A vulnerability, which was classified as critical, has been found in Tenda O3V2 1.0.0.12(3880). This issue affects the function fromTraceroutGet of the file /goform/getTraceroute of the component httpd. The manipulation of the argument dest leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o3_firmwareo3O3V2
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-7525
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.61% / 81.47%
||
7 Day CHG+0.67%
Published-13 Jul, 2025 | 09:32
Updated-15 Jul, 2025 | 20:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK T6 HTTP POST Request cstecgi.cgi setTracerouteCfg command injection

A vulnerability was found in TOTOLINK T6 4.1.5cu.748_B20211015. It has been declared as critical. This vulnerability affects the function setTracerouteCfg of the file /cgi-bin/cstecgi.cgi of the component HTTP POST Request Handler. The manipulation of the argument command leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-t6_firmwaret6T6
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-7524
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.61% / 81.47%
||
7 Day CHG+0.67%
Published-13 Jul, 2025 | 09:02
Updated-15 Jul, 2025 | 20:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK T6 HTTP POST Request cstecgi.cgi setDiagnosisCfg command injection

A vulnerability was found in TOTOLINK T6 4.1.5cu.748_B20211015. It has been classified as critical. This affects the function setDiagnosisCfg of the file /cgi-bin/cstecgi.cgi of the component HTTP POST Request Handler. The manipulation of the argument ip leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-t6_firmwaret6T6
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-7192
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.17% / 38.61%
||
7 Day CHG+0.10%
Published-08 Jul, 2025 | 19:32
Updated-14 Jul, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-645 ssdpcgi cgibin ssdpcgi_main command injection

A vulnerability was found in D-Link DIR-645 up to 1.05B01 and classified as critical. This issue affects the function ssdpcgi_main of the file /htdocs/cgibin of the component ssdpcgi. The manipulation leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-645_firmwaredir-645DIR-645
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-7081
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.96% / 76.17%
||
7 Day CHG~0.00%
Published-06 Jul, 2025 | 13:32
Updated-09 Jul, 2025 | 17:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Belkin F9K1122 webs formSetWanStatic os command injection

A vulnerability has been found in Belkin F9K1122 1.00.33 and classified as critical. Affected by this vulnerability is the function formSetWanStatic of the file /goform/formSetWanStatic of the component webs. The manipulation of the argument m_wan_ipaddr/m_wan_netmask/m_wan_gateway/m_wan_staticdns1/m_wan_staticdns2 is directly passed by the attacker/so we can control the m_wan_ipaddr/m_wan_netmask/m_wan_gateway/m_wan_staticdns1/m_wan_staticdns2 leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Belkin International, Inc.
Product-f9k1122f9k1122_firmwareF9K1122
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-7083
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.96% / 76.17%
||
7 Day CHG~0.00%
Published-06 Jul, 2025 | 15:32
Updated-09 Jul, 2025 | 17:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Belkin F9K1122 webs mp os command injection

A vulnerability was found in Belkin F9K1122 1.00.33. It has been classified as critical. This affects the function mp of the file /goform/mp of the component webs. The manipulation of the argument command leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Belkin International, Inc.
Product-f9k1122f9k1122_firmwareF9K1122
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-7082
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.96% / 76.17%
||
7 Day CHG~0.00%
Published-06 Jul, 2025 | 14:02
Updated-09 Jul, 2025 | 17:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Belkin F9K1122 webs formBSSetSitesurvey os command injection

A vulnerability was found in Belkin F9K1122 1.00.33 and classified as critical. Affected by this issue is the function formBSSetSitesurvey of the file /goform/formBSSetSitesurvey of the component webs. The manipulation of the argument wan_ipaddr/wan_netmask/wan_gateway/wl_ssid is directly passed by the attacker/so we can control the wan_ipaddr/wan_netmask/wan_gateway/wl_ssid leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Belkin International, Inc.
Product-f9k1122f9k1122_firmwareF9K1122
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-7154
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-2.08% / 83.72%
||
7 Day CHG+1.18%
Published-08 Jul, 2025 | 00:32
Updated-16 Jul, 2025 | 19:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK N200RE cstecgi.cgi sub_41A0F8 os command injection

A vulnerability, which was classified as critical, has been found in TOTOLINK N200RE 9.3.5u.6095_B20200916/9.3.5u.6139_B20201216. Affected by this issue is the function sub_41A0F8 of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument Hostname leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-n200ren200re_firmwareN200RE
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-7414
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.62% / 69.81%
||
7 Day CHG+0.26%
Published-10 Jul, 2025 | 20:32
Updated-16 Jul, 2025 | 15:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O3V2 httpd setPingInfo fromNetToolGet os command injection

A vulnerability classified as critical was found in Tenda O3V2 1.0.0.12(3880). This vulnerability affects the function fromNetToolGet of the file /goform/setPingInfo of the component httpd. The manipulation of the argument domain leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o3_firmwareo3O3V2
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-6896
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.17% / 38.61%
||
7 Day CHG~0.00%
Published-30 Jun, 2025 | 07:02
Updated-14 Jul, 2025 | 17:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DI-7300G+ wget_test.asp os command injection

A vulnerability classified as critical has been found in D-Link DI-7300G+ 19.12.25A1. Affected is an unknown function of the file wget_test.asp. The manipulation of the argument url leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-di-7300g\+_firmwaredi-7300g\+DI-7300G+
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-2982
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.5||MEDIUM
EPSS-2.89% / 86.09%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 15:31
Updated-14 Jan, 2025 | 15:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1202 WriteFacMac formWriteFacMac command injection

A vulnerability has been found in Tenda FH1202 1.2.0.14(408) and classified as critical. Affected by this vulnerability is the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to command injection. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-258151. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1202_firmwarefh1202FH1202fh1202_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-6898
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.12% / 31.40%
||
7 Day CHG~0.00%
Published-30 Jun, 2025 | 08:02
Updated-14 Jul, 2025 | 17:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DI-7300G+ in proxy_client.asp os command injection

A vulnerability, which was classified as critical, has been found in D-Link DI-7300G+ 19.12.25A1. Affected by this issue is some unknown functionality of the file in proxy_client.asp. The manipulation of the argument proxy_srv/proxy_lanport/proxy_lanip/proxy_srvport leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-di-7300g\+_firmwaredi-7300g\+DI-7300G+
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-6899
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.18% / 39.41%
||
7 Day CHG~0.00%
Published-30 Jun, 2025 | 08:32
Updated-14 Jul, 2025 | 17:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DI-7300G+/DI-8200G msp_info.htm os command injection

A vulnerability, which was classified as critical, was found in D-Link DI-7300G+ and DI-8200G 17.12.20A1/19.12.25A1. This affects an unknown part of the file msp_info.htm. The manipulation of the argument flag/cmd/iface leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-di-7300g\+_firmwaredi-8200gdi-8200g_firmwaredi-7300g\+DI-8200GDI-7300G+
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-51258
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.18% / 39.74%
||
7 Day CHG~0.00%
Published-30 Oct, 2024 | 00:00
Updated-10 Apr, 2025 | 15:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

DrayTek Vigor3900 1.5.1.3 allows attackers to inject malicious commands into mainfunction.cgi and execute arbitrary commands by calling the doSSLTunnel function.

Action-Not Available
Vendor-n/aDrayTek Corp.
Product-vigor3900_firmwarevigor3900n/avigor3900_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-2526
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.35% / 57.09%
||
7 Day CHG+0.09%
Published-16 Feb, 2026 | 01:02
Updated-23 Feb, 2026 | 10:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Wavlink WL-WN579A3 wireless.cgi multi_ssid command injection

A vulnerability was found in Wavlink WL-WN579A3 up to 20210219. This impacts the function multi_ssid of the file /cgi-bin/wireless.cgi. Performing a manipulation of the argument SSID2G2 results in command injection. The attack may be initiated remotely. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wl-wn579a3_firmwarewl-wn579a3WL-WN579A3
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-51296
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.13% / 33.05%
||
7 Day CHG~0.00%
Published-30 Oct, 2024 | 00:00
Updated-10 Apr, 2025 | 15:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Draytek Vigor3900 1.5.1.3, attackers can inject malicious commands into mainfunction.cgi and execute arbitrary commands by calling the pingtrace function.

Action-Not Available
Vendor-n/aDrayTek Corp.
Product-vigor3900_firmwarevigor3900n/avigor3900_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-66399
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-7.4||HIGH
EPSS-0.13% / 32.75%
||
7 Day CHG~0.00%
Published-02 Dec, 2025 | 17:57
Updated-08 Dec, 2025 | 21:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
SNMP Command Injection leads to RCE in Cacti

Cacti is an open source performance and fault management framework. Prior to 1.2.29, there is an input-validation flaw in the SNMP device configuration functionality. An authenticated Cacti user can supply crafted SNMP community strings containing control characters (including newlines) that are accepted, stored verbatim in the database, and later embedded into backend SNMP operations. In environments where downstream SNMP tooling or wrappers interpret newline-separated tokens as command boundaries, this can lead to unintended command execution with the privileges of the Cacti process. This vulnerability is fixed in 1.2.29.

Action-Not Available
Vendor-The Cacti Group, Inc.
Product-cacticacti
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
  • Previous
  • 1
  • 2
  • 3
  • 4
  • 5
  • ...
  • 10
  • 11
  • Next
Details not found