Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2023-27983

Summary
Assigner-schneider
Assigner Org ID-076d1eb6-cfab-4401-b34d-6dfc2a413bdb
Published At-21 Mar, 2023 | 00:00
Updated At-05 Feb, 2025 | 20:05
Rejected At-
Credits

A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Data Server TCP interface that could allow deletion of reports from the IGSS project report directory, this would lead to loss of data when an attacker abuses this functionality. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior).

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:schneider
Assigner Org ID:076d1eb6-cfab-4401-b34d-6dfc2a413bdb
Published At:21 Mar, 2023 | 00:00
Updated At:05 Feb, 2025 | 20:05
Rejected At:
▼CVE Numbering Authority (CNA)

A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Data Server TCP interface that could allow deletion of reports from the IGSS project report directory, this would lead to loss of data when an attacker abuses this functionality. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior).

Affected Products
Vendor
Schneider Electric SESchneider Electric
Product
IGSS Data Server(IGSSdataServer.exe)
Versions
Affected
  • From V through 16.0.0.23040 (custom)
Vendor
Schneider Electric SESchneider Electric
Product
IGSS Dashboard (DashBoard.exe)
Versions
Affected
  • From V through 16.0.0.23040 (custom)
Vendor
Schneider Electric SESchneider Electric
Product
Custom Reports (RMS16.dll)
Versions
Affected
  • From V through 16.0.0.23040 (custom)
Problem Types
TypeCWE IDDescription
CWECWE-306CWE-306 Missing Authentication for Critical Function
Type: CWE
CWE ID: CWE-306
Description: CWE-306 Missing Authentication for Critical Function
Metrics
VersionBase scoreBase severityVector
3.16.5MEDIUM
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L
Version: 3.1
Base score: 6.5
Base severity: MEDIUM
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-073-04.pdf
N/A
Hyperlink: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-073-04.pdf
Resource: N/A
▼Authorized Data Publishers (ADP)
1. CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-073-04.pdf
x_transferred
Hyperlink: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-073-04.pdf
Resource:
x_transferred
2. CISA ADP Vulnrichment
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cybersecurity@se.com
Published At:21 Mar, 2023 | 14:15
Updated At:28 Mar, 2023 | 15:10

A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Data Server TCP interface that could allow deletion of reports from the IGSS project report directory, this would lead to loss of data when an attacker abuses this functionality. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior).

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.15.3MEDIUM
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N
Secondary3.16.5MEDIUM
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L
Type: Primary
Version: 3.1
Base score: 5.3
Base severity: MEDIUM
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N
Type: Secondary
Version: 3.1
Base score: 6.5
Base severity: MEDIUM
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L
CPE Matches

Schneider Electric SE
schneider-electric
>>custom_reports>>Versions up to 16.0.0.23040(inclusive)
cpe:2.3:a:schneider-electric:custom_reports:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>igss_dashboard>>Versions up to 16.0.0.23040(inclusive)
cpe:2.3:a:schneider-electric:igss_dashboard:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>igss_data_server>>Versions up to 16.0.0.23040(inclusive)
cpe:2.3:a:schneider-electric:igss_data_server:*:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-306Primarycybersecurity@se.com
CWE ID: CWE-306
Type: Primary
Source: cybersecurity@se.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-073-04.pdfcybersecurity@se.com
Patch
Vendor Advisory
Hyperlink: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-073-04.pdf
Source: cybersecurity@se.com
Resource:
Patch
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

69Records found

CVE-2022-22809
Matching Score-10
Assigner-Schneider Electric
ShareView Details
Matching Score-10
Assigner-Schneider Electric
CVSS Score-5.3||MEDIUM
EPSS-0.39% / 59.23%
||
7 Day CHG~0.00%
Published-09 Feb, 2022 | 00:00
Updated-03 Aug, 2024 | 03:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow modifications of the touch configurations in an unauthorized manner when an attacker attempts to modify the touch configurations. Affected Product: spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior)

Action-Not Available
Vendor-n/a
Product-fellerlynkwiser_for_knxspacelynkwiser_for_knx_firmwarefellerlynk_firmwarespacelynk_firmwarespaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior)
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2023-0595
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-5.3||MEDIUM
EPSS-0.07% / 20.82%
||
7 Day CHG~0.00%
Published-24 Feb, 2023 | 00:00
Updated-05 Feb, 2025 | 20:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-117: Improper Output Neutralization for Logs vulnerability exists that could cause the misinterpretation of log files when malicious packets are sent to the Geo SCADA server's database web port (default 443). Affected products: EcoStruxure Geo SCADA Expert 2019, EcoStruxure Geo SCADA Expert 2020, EcoStruxure Geo SCADA Expert 2021(All Versions prior to October 2022), ClearSCADA (All Versions)

Action-Not Available
Vendor-Schneider Electric SE
Product-clearscadaecostruxure_geo_scada_expert_2021ecostruxure_geo_scada_expert_2020ecostruxure_geo_scada_expert_2019EcoStruxure Geo SCADA Expert 2020EcoStruxure Geo SCADA Expert 2021EcoStruxure Geo SCADA Expert 2019ClearSCADA
CWE ID-CWE-117
Improper Output Neutralization for Logs
CWE ID-CWE-116
Improper Encoding or Escaping of Output
CVE-2024-10498
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-6.9||MEDIUM
EPSS-0.10% / 28.80%
||
7 Day CHG+0.01%
Published-17 Jan, 2025 | 10:30
Updated-12 Feb, 2025 | 16:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could allow an unauthorized attacker to modify configuration values outside of the normal range when the attacker sends specific Modbus write packets to the device which could result in invalid data or loss of web interface functionality.

Action-Not Available
Vendor-Schneider Electric SE
Product-PowerLogic HDPM6000
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2017-6030
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-6.5||MEDIUM
EPSS-0.39% / 59.51%
||
7 Day CHG~0.00%
Published-30 Jun, 2017 | 02:35
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Predictable Value Range from Previous Values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The affected products generate insufficiently random TCP initial sequence numbers that may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-modicon_m241modicon_m221modicon_m241_firmwaremodicon_m221_firmwaremodicon_m251_firmwaremodicon_m251Schneider Electric Modicon PLCs
CWE ID-CWE-331
Insufficient Entropy
CWE ID-CWE-343
Predictable Value Range from Previous Values
CVE-2022-34765
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-5.5||MEDIUM
EPSS-0.27% / 50.47%
||
7 Day CHG~0.00%
Published-13 Jul, 2022 | 21:11
Updated-16 Sep, 2024 | 19:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-73: External Control of File Name or Path vulnerability exists that could cause loading of unauthorized firmware images when user-controlled data is written to the file path. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V2.01 and later), OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior)

Action-Not Available
Vendor-
Product-opc_ua_module_for_m580opc_ua_module_for_m580_firmwarex80_advanced_rtu_module_firmwarex80_advanced_rtu_moduleOPC UA Modicon Communication ModuleX80 advanced RTU Communication Module
CWE ID-CWE-73
External Control of File Name or Path
CWE ID-CWE-668
Exposure of Resource to Wrong Sphere
CVE-2024-5056
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-6.5||MEDIUM
EPSS-0.13% / 33.29%
||
7 Day CHG~0.00%
Published-12 Jun, 2024 | 12:10
Updated-23 Aug, 2024 | 16:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-552: Files or Directories Accessible to External Parties vulnerability exists which may prevent user to update the device firmware and prevent proper behavior of the webserver when specific files or directories are removed from the filesystem.

Action-Not Available
Vendor-
Product-bmxnoe0110_firmwarebmxnoe0100bmxnoe0110modicon_m340modicon_m340_firmwarebmxnoe0100_firmwareModicon M340Network module, Modicon M340, Modbus/TCP BMXNOE0100Network module, Modicon M340, Ethernet TCP/IP BMXNOE0110modicom_m340_firmwaremodicom_m340
CWE ID-CWE-552
Files or Directories Accessible to External Parties
CVE-2023-27977
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-6.5||MEDIUM
EPSS-0.06% / 18.91%
||
7 Day CHG~0.00%
Published-21 Mar, 2023 | 00:00
Updated-05 Feb, 2025 | 20:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could cause access to delete files in the IGSS project report directory, this could lead to loss of data when an attacker sends specific crafted messages to the Data Server TCP port. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior).

Action-Not Available
Vendor-Schneider Electric SE
Product-custom_reportsigss_dashboardigss_data_serverIGSS Dashboard (DashBoard.exe)IGSS Data Server(IGSSdataServer.exe)Custom Reports (RMS16.dll)
CWE ID-CWE-345
Insufficient Verification of Data Authenticity
CVE-2023-27979
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-6.5||MEDIUM
EPSS-0.07% / 22.88%
||
7 Day CHG~0.00%
Published-21 Mar, 2023 | 00:00
Updated-05 Feb, 2025 | 20:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could allow the renaming of files in the IGSS project report directory, this could lead to denial of service when an attacker sends specific crafted messages to the Data Server TCP port. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior).

Action-Not Available
Vendor-Schneider Electric SE
Product-custom_reportsigss_dashboardigss_data_serverIGSS Dashboard (DashBoard.exe)IGSS Data Server(IGSSdataServer.exe)Custom Reports (RMS16.dll)
CWE ID-CWE-345
Insufficient Verification of Data Authenticity
CVE-2018-7778
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.69% / 70.91%
||
7 Day CHG~0.00%
Published-03 Jul, 2018 | 14:00
Updated-17 Sep, 2024 | 01:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Schneider Electric Evlink Charging Station versions prior to v3.2.0-12_v1, the Web Interface has an issue that may allow a remote attacker to gain administrative privileges without properly authenticating remote users.

Action-Not Available
Vendor-
Product-evlink_charging_stationevlink_charging_station_firmwareEvlink Charging Station
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2023-4516
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.03% / 5.96%
||
7 Day CHG~0.00%
Published-14 Sep, 2023 | 08:54
Updated-27 Feb, 2025 | 20:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-306: Missing Authentication for Critical Function vulnerability exists in the IGSS Update Service that could allow a local attacker to change update source, potentially leading to remote code execution when the attacker force an update containing malicious content.

Action-Not Available
Vendor-Schneider Electric SE
Product-interactive_graphical_scada_systemIGSS Update Service (IGSSupdateservice.exe)
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2021-22772
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.21% / 43.24%
||
7 Day CHG~0.00%
Published-21 Jul, 2021 | 10:41
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-306: Missing Authentication for Critical Function vulnerability exists in Easergy T200 ((Modbus) SC2-04MOD-07000100 and earlier), Easergy T200 ((IEC104) SC2-04IEC-07000100 and earlier), and Easergy T200 ((DNP3) SC2-04DNP-07000102 and earlier) that could cause unauthorized operation when authentication is bypassed.

Action-Not Available
Vendor-n/a
Product-t200et200i_firmwaret200it200pt200e_firmwaret200p_firmwareEasergy T200 ((Modbus) SC2-04MOD-07000100 and earlier), Easergy T200 ((IEC104) SC2-04IEC-07000100 and earlier), and Easergy T200 ((DNP3) SC2-04DNP-07000102 and earlier)
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2021-22805
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-9.1||CRITICAL
EPSS-0.23% / 45.97%
||
7 Day CHG~0.00%
Published-11 Feb, 2022 | 17:40
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_system_data_collectorInteractive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2024-8530
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-5.9||MEDIUM
EPSS-0.11% / 29.45%
||
7 Day CHG~0.00%
Published-11 Oct, 2024 | 13:55
Updated-17 Oct, 2024 | 19:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause exposure of private data when an already generated “logcaptures” archive is accessed directly by HTTPS.

Action-Not Available
Vendor-
Product-Data Center Expertdata_center_expert
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2020-7561
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.59% / 80.88%
||
7 Day CHG~0.00%
Published-19 Nov, 2020 | 00:00
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-306: Missing Authentication for Critical Function vulnerability exists in Easergy T300 (with firmware 2.7 and older) that could cause a wide range of problems, including information exposure, denial of service, and command execution when access to a resource from an attacker is not restricted or incorrectly restricted.

Action-Not Available
Vendor-n/a
Product-easergy_t300easergy_t300_firmwareEasergy T300 with firmware 2.7 and older
CWE ID-CWE-284
Improper Access Control
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2020-7540
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.31% / 53.66%
||
7 Day CHG~0.00%
Published-11 Dec, 2020 | 00:52
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause unauthenticated command execution in the controller when sending special HTTP requests.

Action-Not Available
Vendor-n/a
Product-140noc78100140cpu65150140noc78000_firmwaretsxp575634_firmware140noc78000bmxnoe0110_firmware140cpu65160_firmwaretsxp574634modicon_m340_bmxp3420102clmodicon_m340_bmxp3420302_firmwarebmxnor200h_firmware140noc78100_firmwaremodicon_m340_bmxp342000140cpu65160modicon_m340_bmxp3420302cl_firmwaremodicon_m340_bmxp341000140noe77111_firmwaremodicon_m340_bmxp342020_firmware140noc77101_firmwaremodicon_m340_bmxp3420102_firmware140noc77101bmxnoe0110140noe77101tsxety5103_firmwaremodicon_m340_bmxp3420102cl_firmwaretsxety5103tsxp574634_firmwarebmxnoc0401_firmware140noe77111modicon_m340_bmxp3420302clmodicon_m340_bmxp3420302140noe77101_firmwaremodicon_m340_bmxp342020bmxnoe0100_firmwaretsxp576634modicon_m340_bmxp341000_firmwaretsxety4103_firmwarebmxnor200htsxp576634_firmwarebmxnoc0401modicon_m340_bmxp342000_firmwarebmxnoe0100140cpu65150_firmwaremodicon_m340_bmxp3420102tsxety4103tsxp575634Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions)
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2023-29411
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-5.99% / 90.32%
||
7 Day CHG~0.00%
Published-18 Apr, 2023 | 20:49
Updated-05 Feb, 2025 | 21:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow changes to administrative credentials, leading to potential remote code execution without requiring prior authentication on the Java RMI interface.

Action-Not Available
Vendor-Microsoft CorporationSchneider Electric SE
Product-windows_server_2016apc_easy_ups_online_monitoring_softwareeasy_ups_online_monitoring_softwarewindows_11windows_10windows_server_2022windows_server_2019Schneider Electric Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)APC Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2023-27980
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-2.12% / 83.44%
||
7 Day CHG~0.00%
Published-21 Mar, 2023 | 00:00
Updated-05 Feb, 2025 | 20:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Data Server TCP interface that could allow the creation of a malicious report file in the IGSS project report directory, this could lead to remote code execution when a victim eventually opens the report. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior)

Action-Not Available
Vendor-Schneider Electric SE
Product-custom_reportsigss_dashboardigss_data_serverIGSS Dashboard (DashBoard.exe)IGSS Data Server(IGSSdataServer.exe)Custom Reports (RMS16.dll)
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-6808
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-3.84% / 87.70%
||
7 Day CHG~0.00%
Published-22 May, 2019 | 20:05
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a remote code execution by overwriting configuration settings of the controller over Modbus.

Action-Not Available
Vendor-n/a
Product-modicon_quantummodicon_quantum_firmwaremodicon_m580_firmwaremodicon_premium_firmwaremodicon_premiummodicon_m340modicon_m340_firmwaremodicon_m580Modicon M580 Modicon M340 Modicon Quantum Modicon Premium
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2023-29413
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.26% / 49.32%
||
7 Day CHG~0.00%
Published-18 Apr, 2023 | 20:50
Updated-05 Feb, 2025 | 20:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause Denial-of-Service when accessed by an unauthenticated user on the Schneider UPS Monitor service.

Action-Not Available
Vendor-Microsoft CorporationSchneider Electric SE
Product-windows_server_2016apc_easy_ups_online_monitoring_softwareeasy_ups_online_monitoring_softwarewindows_11windows_10windows_server_2022windows_server_2019Schneider Electric Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)APC Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-6820
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-8.2||HIGH
EPSS-0.38% / 58.86%
||
7 Day CHG~0.00%
Published-22 May, 2019 | 19:40
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-306: Missing Authentication for Critical Function vulnerability exists which could cause a modification of device IP configuration (IP address, network mask and gateway IP address) when a specific Ethernet frame is received in all versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2

Action-Not Available
Vendor-n/a
Product-pacdrive_ecomodicon_m241_firmwarepacdrive_pro2_firmwaremodicon_m200_firmwarepacdrive_eco_firmwaremodicon_m221_firmwaremodicon_m241modicon_m258atv_imc_drive_controller_firmwaremodicon_m258_firmwareatv_imc_drive_controllermodicon_m251_firmwaremodicon_m200modicon_lmc078modicon_m100_firmwarepacdrive_promodicon_m221pacdrive_pro2pacdrive_pro_firmwaremodicon_lmc078_firmwaremodicon_lmc058modicon_m100modicon_lmc058_firmwaremodicon_m251Modicon and PacDrive Controller, All versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2017-13997
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-1.59% / 80.87%
||
7 Day CHG~0.00%
Published-02 Oct, 2017 | 05:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Missing Authentication for Critical Function issue was discovered in Schneider Electric InduSoft Web Studio v8.0 SP2 or prior, and InTouch Machine Edition v8.0 SP2 or prior. InduSoft Web Studio provides the capability for an HMI client to trigger script execution on the server for the purposes of performing customized calculations or actions. A remote malicious entity could bypass the server authentication and trigger the execution of an arbitrary command. The command is executed under high privileges and could lead to a complete compromise of the server.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-wonderware_intouchwonderware_indusoft_web_studioSchneider Electric InduSoft Web Studio, InTouch Machine Edition
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2021-22784
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-5.7||MEDIUM
EPSS-0.23% / 45.43%
||
7 Day CHG~0.00%
Published-21 Jul, 2021 | 10:40
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-306: Missing Authentication for Critical Function vulnerability exists in C-Bus Toolkit v1.15.8 and prior that could allow an attacker to use a crafted webpage to obtain remote access to the system.

Action-Not Available
Vendor-n/a
Product-c-bus_toolkitC-Bus Toolkit v1.15.8 and prior
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2021-22823
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-9.1||CRITICAL
EPSS-1.75% / 81.77%
||
7 Day CHG~0.00%
Published-11 Feb, 2022 | 17:40
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_system_data_collectorInteractive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2022-42970
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.23% / 45.82%
||
7 Day CHG~0.00%
Published-01 Feb, 2023 | 00:00
Updated-05 Feb, 2025 | 20:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-306: Missing Authentication for Critical Function The software does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)

Action-Not Available
Vendor-Microsoft CorporationSchneider Electric SE
Product-windows_server_2016apc_easy_ups_online_monitoring_softwareeasy_ups_online_monitoring_softwarewindows_7windows_11windows_10windows_server_2022windows_server_2019Schneider Electric Easy UPS Online Monitoring SoftwareAPC Easy UPS Online Monitoring Software
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2020-7479
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.15% / 35.93%
||
7 Day CHG~0.00%
Published-23 Mar, 2020 | 19:18
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-306: Missing Authentication for Critical Function vulnerability exists in IGSS (Versions 14 and prior using the service: IGSSupdate), which could allow a local user to execute processes that otherwise require escalation privileges when sending local network commands to the IGSS Update Service.

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_systemIGSS (Interactive Graphical SCADA System) (IGSS Version prior to 14.0.0.20009)
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2022-32528
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-8.6||HIGH
EPSS-0.08% / 24.78%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause access to manipulate and read specific files in the IGSS project report directory, potentially leading to a denial-of-service condition when an attacker sends specific messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)

Action-Not Available
Vendor-Schneider Electric SE
Product-interactive_graphical_scada_systemIGSS Data Server (IGSSdataServer.exe)
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-0379
Matching Score-4
Assigner-SAP SE
ShareView Details
Matching Score-4
Assigner-SAP SE
CVSS Score-5.3||MEDIUM
EPSS-0.22% / 44.30%
||
7 Day CHG~0.00%
Published-08 Oct, 2019 | 19:27
Updated-04 Aug, 2024 | 17:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

SAP Process Integration, business-to-business add-on, versions 1.0, 2.0, does not perform authentication check properly when the default security provider is changed to BouncyCastle (BC), leading to Missing Authentication Check

Action-Not Available
Vendor-SAP SE
Product-process_integrationSAP Process Integration, business-to-business add-on
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2024-26011
Matching Score-4
Assigner-Fortinet, Inc.
ShareView Details
Matching Score-4
Assigner-Fortinet, Inc.
CVSS Score-5.2||MEDIUM
EPSS-0.04% / 13.09%
||
7 Day CHG~0.00%
Published-12 Nov, 2024 | 18:53
Updated-12 Dec, 2024 | 19:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A missing authentication for critical function in Fortinet FortiManager version 7.4.0 through 7.4.2, 7.2.0 through 7.2.4, 7.0.0 through 7.0.11, 6.4.0 through 6.4.14, FortiPAM version 1.2.0, 1.1.0 through 1.1.2, 1.0.0 through 1.0.3, FortiProxy version 7.4.0 through 7.4.2, 7.2.0 through 7.2.9, 7.0.0 through 7.0.17, 2.0.0 through 2.0.14, 1.2.0 through 1.2.13, 1.1.0 through 1.1.6, 1.0.0 through 1.0.7, FortiSwitchManager version 7.2.0 through 7.2.3, 7.0.0 through 7.0.3, FortiPortal version 6.0.0 through 6.0.14, FortiOS version 7.4.0 through 7.4.3, 7.2.0 through 7.2.7, 7.0.0 through 7.0.14, 6.4.0 through 6.4.15, 6.2.0 through 6.2.16, 6.0.0 through 6.0.18 allows attacker to execute unauthorized code or commands via specially crafted packets.

Action-Not Available
Vendor-Fortinet, Inc.
Product-fortimanagerfortiswitchmanagerfortiportalfortipamfortiproxyfortiosFortiProxyFortiSwitchManagerFortiPortalFortiPAMFortiOSFortiManager
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2018-20507
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-5.3||MEDIUM
EPSS-0.11% / 30.76%
||
7 Day CHG~0.00%
Published-30 Dec, 2019 | 21:24
Updated-05 Aug, 2024 | 12:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in GitLab Enterprise Edition 11.2.x through 11.4.x before 11.4.13, 11.5.x before 11.5.6, and 11.6.x before 11.6.1. It has Incorrect Access Control.

Action-Not Available
Vendor-n/aGitLab Inc.
Product-gitlabn/a
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2025-4018
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-6.9||MEDIUM
EPSS-0.11% / 30.04%
||
7 Day CHG~0.00%
Published-28 Apr, 2025 | 11:31
Updated-29 Apr, 2025 | 13:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
20120630 Novel-Plus CrawlController.java addCrawlSource missing authentication

A vulnerability, which was classified as critical, has been found in 20120630 Novel-Plus up to 0e156c04b4b7ce0563bef6c97af4476fcda8f160. This issue affects the function addCrawlSource of the file novel-crawl/src/main/java/com/java2nb/novel/controller/CrawlController.java. The manipulation leads to missing authentication. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-20120630
Product-Novel-Plus
CWE ID-CWE-287
Improper Authentication
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2025-32782
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-5.3||MEDIUM
EPSS-0.09% / 27.01%
||
7 Day CHG~0.00%
Published-15 Apr, 2025 | 22:04
Updated-16 Apr, 2025 | 15:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Ash Authentication email link auto-click account confirmation vulnerability

Ash Authentication provides authentication for the Ash framework. The confirmation flow for account creation currently uses a GET request triggered by clicking a link sent via email. Some email clients and security tools (e.g., Outlook, virus scanners, and email previewers) may automatically follow these links, unintentionally confirming the account. This allows an attacker to register an account using another user’s email and potentially have it auto-confirmed by the victim’s email client. This does not allow attackers to take over or access existing accounts or private data. It is limited to account confirmation of new accounts only. This vulnerability is fixed in 4.7.0.

Action-Not Available
Vendor-team-alembic
Product-ash_authentication
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2023-46819
Matching Score-4
Assigner-Apache Software Foundation
ShareView Details
Matching Score-4
Assigner-Apache Software Foundation
CVSS Score-5.3||MEDIUM
EPSS-0.30% / 52.76%
||
7 Day CHG-0.01%
Published-07 Nov, 2023 | 11:02
Updated-04 Sep, 2024 | 19:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Apache OFBiz: Execution of Solr plugin queries without authentication

Missing Authentication in Apache Software Foundation Apache OFBiz when using the Solr plugin. This issue affects Apache OFBiz: before 18.12.09.  Users are recommended to upgrade to version 18.12.09

Action-Not Available
Vendor-The Apache Software Foundation
Product-ofbizApache OFBiz
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2025-32738
Matching Score-4
Assigner-JPCERT/CC
ShareView Details
Matching Score-4
Assigner-JPCERT/CC
CVSS Score-6.9||MEDIUM
EPSS-0.08% / 25.05%
||
7 Day CHG~0.00%
Published-15 May, 2025 | 08:48
Updated-15 May, 2025 | 13:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Missing authentication for critical function issue exists in I-O DATA network attached hard disk 'HDL-T Series' firmware Ver.1.21 and earlier. If exploited, a remote unauthenticated attacker may change the product settings.

Action-Not Available
Vendor-I-O DATA DEVICE, INC.
Product-HDL-T1WHHDL-T3WHHDL-T3NVHDL-T2WHHDL-T1NVHDL-T2NVHDL-TC500HDL-TC1
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2025-32377
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-6.5||MEDIUM
EPSS-0.10% / 27.70%
||
7 Day CHG~0.00%
Published-18 Apr, 2025 | 19:59
Updated-21 Apr, 2025 | 14:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Rasa Pro Missing Authentication For Voice Connector APIs

Rasa Pro is a framework for building scalable, dynamic conversational AI assistants that integrate large language models (LLMs). A vulnerability has been identified in Rasa Pro where voice connectors in Rasa Pro do not properly implement authentication even when a token is configured in the credentials.yml file. This could allow an attacker to submit voice data to the Rasa Pro assistant from an unauthenticated source. This issue has been patched for audiocodes, audiocodes_stream, and genesys connectors in versions 3.9.20, 3.10.19, 3.11.7 and 3.12.6.

Action-Not Available
Vendor-RasaHQ
Product-rasa-pro-security-advisories
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2021-27569
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-5.3||MEDIUM
EPSS-0.06% / 20.15%
||
7 Day CHG~0.00%
Published-07 May, 2021 | 16:31
Updated-03 Aug, 2024 | 21:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in Emote Remote Mouse through 4.0.0.0. Attackers can maximize or minimize the window of a running process by sending the process name in a crafted packet. This information is sent in cleartext and is not protected by any authentication logic.

Action-Not Available
Vendor-remotemousen/a
Product-emote_remote_mousen/a
CWE ID-CWE-319
Cleartext Transmission of Sensitive Information
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2025-26360
Matching Score-4
Assigner-Nozomi Networks Inc.
ShareView Details
Matching Score-4
Assigner-Nozomi Networks Inc.
CVSS Score-5.3||MEDIUM
EPSS-0.12% / 31.43%
||
7 Day CHG+0.01%
Published-12 Feb, 2025 | 13:29
Updated-17 Feb, 2025 | 10:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-306 "Missing Authentication for Critical Function" in maxprofile/persistance/routes.lua in Q-Free MaxTime less than or equal to version 2.11.0 allows an unauthenticated remote attacker to delete dashboards via crafted HTTP requests.

Action-Not Available
Vendor-Q-Free
Product-MaxTime
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2021-24219
Matching Score-4
Assigner-WPScan
ShareView Details
Matching Score-4
Assigner-WPScan
CVSS Score-5.3||MEDIUM
EPSS-0.18% / 39.61%
||
7 Day CHG~0.00%
Published-12 Apr, 2021 | 14:02
Updated-03 Aug, 2024 | 19:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
All Thrive Themes and Plugins - Unauthenticated Option Update

The Thrive Optimize WordPress plugin before 1.4.13.3, Thrive Comments WordPress plugin before 1.4.15.3, Thrive Headline Optimizer WordPress plugin before 1.3.7.3, Thrive Leads WordPress plugin before 2.3.9.4, Thrive Ultimatum WordPress plugin before 2.3.9.4, Thrive Quiz Builder WordPress plugin before 2.3.9.4, Thrive Apprentice WordPress plugin before 2.3.9.4, Thrive Visual Editor WordPress plugin before 2.6.7.4, Thrive Dashboard WordPress plugin before 2.3.9.3, Thrive Ovation WordPress plugin before 2.4.5, Thrive Clever Widgets WordPress plugin before 1.57.1 and Rise by Thrive Themes WordPress theme before 2.0.0, Ignition by Thrive Themes WordPress theme before 2.0.0, Luxe by Thrive Themes WordPress theme before 2.0.0, FocusBlog by Thrive Themes WordPress theme before 2.0.0, Minus by Thrive Themes WordPress theme before 2.0.0, Squared by Thrive Themes WordPress theme before 2.0.0, Voice WordPress theme before 2.0.0, Performag by Thrive Themes WordPress theme before 2.0.0, Pressive by Thrive Themes WordPress theme before 2.0.0, Storied by Thrive Themes WordPress theme before 2.0.0, Thrive Themes Builder WordPress theme before 2.2.4 register a REST API endpoint associated with Zapier functionality. While this endpoint was intended to require an API key in order to access, it was possible to access it by supplying an empty api_key parameter in vulnerable versions if Zapier was not enabled. Attackers could use this endpoint to add arbitrary data to a predefined option in the wp_options table.

Action-Not Available
Vendor-Thrive Themes LLC (Thrive Themes)
Product-thrive_apprenticethrive_ovationfocusblogthrive_quiz_builderignitionthrive_visual_editorstoriedriseluxevoicethrive_optimizethrive_themes_builderthrive_dashboardperformagthrive_commentsminussquaredpressivethrive_clever_widgetsthrive_headline_optimizerThrive UltimatumThrive CommentsVoicePerformag by Thrive ThemesStoried by Thrive ThemesThrive LeadsIgnition by Thrive ThemesMinus by Thrive ThemesRise by Thrive ThemesThrive DashboardThrive OvationThrive Themes BuilderThrive OptimizeThrive Clever WidgetsFocusBlog by Thrive ThemesThrive Quiz BuilderThrive ApprenticeSquared by Thrive ThemesLuxe by Thrive ThemesThrive Visual EditorThrive Headline OptimizerPressive by Thrive Themes
CWE ID-CWE-284
Improper Access Control
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2023-36846
Matching Score-4
Assigner-Juniper Networks, Inc.
ShareView Details
Matching Score-4
Assigner-Juniper Networks, Inc.
CVSS Score-5.3||MEDIUM
EPSS-94.28% / 99.93%
||
7 Day CHG~0.00%
Published-17 Aug, 2023 | 19:18
Updated-30 Jul, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Known KEV||Action Due Date - 2023-11-17||Apply mitigations per vendor instructions or discontinue use of the product if mitigations are unavailable.
Junos OS: SRX Series: A vulnerability in J-Web allows an unauthenticated attacker to upload arbitrary files

A Missing Authentication for Critical Function vulnerability in Juniper Networks Junos OS on SRX Series allows an unauthenticated, network-based attacker to cause limited impact to the file system integrity. With a specific request to user.php that doesn't require authentication an attacker is able to upload arbitrary files via J-Web, leading to a loss of integrity for a certain  part of the file system, which may allow chaining to other vulnerabilities. This issue affects Juniper Networks Junos OS on SRX Series: * All versions prior to 20.4R3-S8; * 21.1 versions 21.1R1 and later; * 21.2 versions prior to 21.2R3-S6; * 21.3 versions prior to 21.3R3-S5; * 21.4 versions prior to 21.4R3-S5; * 22.1 versions prior to 22.1R3-S3; * 22.2 versions prior to 22.2R3-S2; * 22.3 versions prior to 22.3R2-S2, 22.3R3; * 22.4 versions prior to 22.4R2-S1, 22.4R3.

Action-Not Available
Vendor-Juniper Networks, Inc.
Product-srx345srx110srx300srx100srx550_hmsrx3600srx240h2srx550msrx240srx1400srx4200srx5800srx380srx5400srx210srx340srx5000srx240msrx5600srx220srx3400junossrx4000srx4100srx320srx650srx4600srx1500srx550Junos OSJunos OS
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2023-36851
Matching Score-4
Assigner-Juniper Networks, Inc.
ShareView Details
Matching Score-4
Assigner-Juniper Networks, Inc.
CVSS Score-5.3||MEDIUM
EPSS-10.47% / 92.94%
||
7 Day CHG~0.00%
Published-26 Sep, 2023 | 19:53
Updated-30 Jul, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Known KEV||Action Due Date - 2023-11-17||Apply mitigations per vendor instructions or discontinue use of the product if mitigations are unavailable.
Junos OS: SRX Series: A vulnerability in J-Web allows an unauthenticated attacker to upload and download arbitrary files

A Missing Authentication for Critical Function vulnerability in Juniper Networks Junos OS on SRX Series allows an unauthenticated, network-based attacker to cause limited impact to the file system integrity. With a specific request to webauth_operation.php that doesn't require authentication, an attacker is able to upload and download arbitrary files via J-Web, leading to a loss of integrity or confidentiality, which may allow chaining to other vulnerabilities. This issue affects Juniper Networks Junos OS on SRX Series: * 21.2 versions prior to 21.2R3-S8; * 21.4 versions prior to 21.4R3-S6; * 22.1 versions prior to 22.1R3-S5; * 22.2 versions prior to 22.2R3-S3; * 22.3 versions prior to 22.3R3-S2; * 22.4 versions prior to 22,4R2-S2, 22.4R3; * 23.2 versions prior to 23.2R1-S2, 23.2R2.

Action-Not Available
Vendor-Juniper Networks, Inc.
Product-ex4300-48p-sex4400srx110ex4300msrx3600ex4200ex3400ex8200-vcex4650ex4300-32f-sex4550ex2200-vcsrx5000ex2300-24mpex9253ex4300-48tdc-afiex2300-24tex3200ex9214srx3400srx320srx1500ex4300-48t-dc-afiex4300-48tsrx345ex4300srx240h2ex4300-48mpex2200-csrx240ex2200ex4300-48tafisrx340srx5600ex4300-24pex4300-48t-ssrx4000junosex4300-32f-dcex6200srx4600srx5800srx550ex2300-48pex2300-cex9200ex9208ex2300srx100ex4550\/vcex4600ex8208ex4300-48tdcsrx550mex3300ex4200-vcsrx4200ex4500-vcex4300-24tsrx380ex4500srx240mex2300mex9204ex6210ex2300-48tsrx4100ex8216ex4300-48t-afiex4300-48pex4300-48t-dcex2300-48mpex4300-32fsrx300ex3300-vcsrx550_hmex4550-vcsrx1400ex4300-mpsrx5400srx210ex9250srx220ex4600-vcex4300-24t-sex9251srx650ex2300-24pex4300-24p-sex4300-vcex8200ex4300-48mp-sJunos OSJunos OS
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2025-23194
Matching Score-4
Assigner-SAP SE
ShareView Details
Matching Score-4
Assigner-SAP SE
CVSS Score-5.3||MEDIUM
EPSS-0.09% / 25.79%
||
7 Day CHG~0.00%
Published-11 Mar, 2025 | 00:32
Updated-11 Mar, 2025 | 02:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Missing Authentication check in SAP NetWeaver Enterprise Portal (OBN component)

SAP NetWeaver Enterprise Portal OBN does not perform proper authentication check for a particular configuration setting. As result, a non-authenticated user can set it to an undesired value causing low impact on integrity. There is no impact on confidentiality or availability of the application.

Action-Not Available
Vendor-SAP SE
Product-SAP NetWeaver Enterprise Portal (OBN component)
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2021-1499
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-5.3||MEDIUM
EPSS-93.66% / 99.84%
||
7 Day CHG~0.00%
Published-06 May, 2021 | 12:41
Updated-08 Nov, 2024 | 23:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Cisco HyperFlex HX Data Platform File Upload Vulnerability

A vulnerability in the web-based management interface of Cisco HyperFlex HX Data Platform could allow an unauthenticated, remote attacker to upload files to an affected device. This vulnerability is due to missing authentication for the upload function. An attacker could exploit this vulnerability by sending a specific HTTP request to an affected device. A successful exploit could allow the attacker to upload files to the affected device with the permissions of the tomcat8 user.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-hyperflex_hx240c_af_m5hyperflex_hx240c_m5hyperflex_hx220c_m5hyperflex_hx220c_edge_m5hyperflex_hx_data_platformhyperflex_hx220c_all_nvme_m5hyperflex_hx220c_af_m5hyperflex_hx240cCisco HyperFlex HX Data Platform
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2022-4240
Matching Score-4
Assigner-Honeywell International Inc.
ShareView Details
Matching Score-4
Assigner-Honeywell International Inc.
CVSS Score-6.5||MEDIUM
EPSS-0.01% / 1.00%
||
7 Day CHG~0.00%
Published-30 May, 2023 | 16:15
Updated-09 Jan, 2025 | 21:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Unauthenticated API allowing an attacker to obtain the information about network resources

Missing Authentication for Critical Function vulnerability in Honeywell OneWireless allows Authentication Bypass. This issue affects OneWireless version 322.1

Action-Not Available
Vendor-Honeywell International Inc.
Product-onewireless_network_wireless_device_manageronewireless_network_wireless_device_manager_firmwareOneWireless
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2025-1754
Matching Score-4
Assigner-GitLab Inc.
ShareView Details
Matching Score-4
Assigner-GitLab Inc.
CVSS Score-5.3||MEDIUM
EPSS-0.05% / 14.35%
||
7 Day CHG~0.00%
Published-26 Jun, 2025 | 05:31
Updated-12 Aug, 2025 | 14:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Missing Authentication for Critical Function in GitLab

An issue has been discovered in GitLab CE/EE affecting all versions from 17.2 before 17.11.5, 18.0 before 18.0.3, and 18.1 before 18.1.1 that could have allowed unauthenticated attackers to upload arbitrary files to public projects by sending crafted API requests, potentially leading to resource abuse and unauthorized content storage.

Action-Not Available
Vendor-GitLab Inc.
Product-gitlabGitLab
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2024-8320
Matching Score-4
Assigner-Ivanti
ShareView Details
Matching Score-4
Assigner-Ivanti
CVSS Score-5.3||MEDIUM
EPSS-0.85% / 73.90%
||
7 Day CHG~0.00%
Published-10 Sep, 2024 | 20:52
Updated-12 Sep, 2024 | 21:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Missing authentication in Network Isolation of Ivanti EPM before 2022 SU6, or the 2024 September update allows a remote unauthenticated attacker to spoof Network Isolation status of managed devices.

Action-Not Available
Vendor-Ivanti Software
Product-endpoint_managerEndpoint Managerautomation
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2024-47865
Matching Score-4
Assigner-JPCERT/CC
ShareView Details
Matching Score-4
Assigner-JPCERT/CC
CVSS Score-5.3||MEDIUM
EPSS-0.16% / 37.26%
||
7 Day CHG~0.00%
Published-20 Nov, 2024 | 07:30
Updated-20 Nov, 2024 | 15:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Missing authentication for critical function vulnerability exists in Rakuten Turbo 5G firmware version V1.3.18 and earlier. If this vulnerability is exploited, a remote unauthenticated attacker may update or downgrade the firmware on the device.

Action-Not Available
Vendor-Rakuten Mobile, Inc.rakuten
Product-Rakuten Turbo 5Gturbo_5g_firmware
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2023-27261
Matching Score-4
Assigner-The Missing Link Australia (TML)
ShareView Details
Matching Score-4
Assigner-The Missing Link Australia (TML)
CVSS Score-5.3||MEDIUM
EPSS-0.19% / 41.67%
||
7 Day CHG~0.00%
Published-25 Oct, 2023 | 10:21
Updated-25 Sep, 2024 | 12:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Missing Authentication In IDAttend’s IDWeb Application

Missing authentication in the DeleteAssignments method in IDAttend’s IDWeb application 3.1.052 and earlier allows deletion of data by unauthenticated attackers.

Action-Not Available
Vendor-idattendIDAttend Pty Ltd
Product-idwebIDWeb
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2023-26579
Matching Score-4
Assigner-The Missing Link Australia (TML)
ShareView Details
Matching Score-4
Assigner-The Missing Link Australia (TML)
CVSS Score-5.3||MEDIUM
EPSS-0.28% / 50.61%
||
7 Day CHG~0.00%
Published-25 Oct, 2023 | 09:46
Updated-11 Sep, 2024 | 13:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Missing Authentication In IDAttend’s IDWeb Application

Missing authentication in the DeleteStaff method in IDAttend’s IDWeb application 3.1.013 allows deletion of staff information by unauthenticated attackers.

Action-Not Available
Vendor-idattendIDAttend Pty Ltd
Product-idwebIDWeb
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2022-29883
Matching Score-4
Assigner-Siemens
ShareView Details
Matching Score-4
Assigner-Siemens
CVSS Score-5.3||MEDIUM
EPSS-0.27% / 50.44%
||
7 Day CHG~0.00%
Published-10 May, 2022 | 09:47
Updated-03 Aug, 2024 | 06:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00). Affected devices do not restrict unauthenticated access to certain pages of the web interface. This could allow an attacker to delete log files without authentication.

Action-Not Available
Vendor-Siemens AG
Product-7kg8501-0aa11-2aa0_firmware7kg8551-0aa01-2aa07kg8501-0aa11-0aa07kg8500-0aa10-0aa0_firmware7kg8501-0aa31-2aa0_firmware7kg8551-0aa02-2aa0_firmware7kg8551-0aa02-0aa0_firmware7kg8551-0aa32-2aa0_firmware7kg8550-0aa00-0aa07kg8550-0aa00-0aa0_firmware7kg8501-0aa01-0aa07kg8551-0aa02-0aa07kg8500-0aa30-0aa07kg8551-0aa32-0aa0_firmware7kg8551-0aa02-2aa07kg8550-0aa30-0aa0_firmware7kg8501-0aa32-0aa07kg8500-0aa30-2aa0_firmware7kg8501-0aa01-0aa0_firmware7kg8501-0aa02-0aa07kg8551-0aa12-2aa07kg8500-0aa00-0aa07kg8551-0aa01-0aa0_firmware7kg8501-0aa11-2aa07kg8501-0aa31-0aa07kg8501-0aa12-2aa0_firmware7kg8501-0aa32-2aa07kg8550-0aa00-2aa0_firmware7kg8550-0aa30-2aa07kg8501-0aa31-0aa0_firmware7kg8550-0aa30-0aa07kg8501-0aa12-0aa0_firmware7kg8551-0aa12-0aa07kg8500-0aa30-2aa07kg8501-0aa32-2aa0_firmware7kg8500-0aa10-2aa0_firmware7kg8500-0aa00-2aa0_firmware7kg8501-0aa01-2aa0_firmware7kg8501-0aa02-0aa0_firmware7kg8500-0aa10-0aa07kg8551-0aa12-0aa0_firmware7kg8550-0aa30-2aa0_firmware7kg8551-0aa32-2aa07kg8501-0aa11-0aa0_firmware7kg8550-0aa10-2aa07kg8501-0aa02-2aa0_firmware7kg8551-0aa32-0aa07kg8501-0aa32-0aa0_firmware7kg8551-0aa12-2aa0_firmware7kg8550-0aa10-0aa0_firmware7kg8501-0aa01-2aa07kg8550-0aa00-2aa07kg8551-0aa31-2aa0_firmware7kg8551-0aa11-2aa07kg8501-0aa12-0aa07kg8551-0aa31-0aa0_firmware7kg8551-0aa11-0aa07kg8500-0aa00-2aa07kg8551-0aa01-2aa0_firmware7kg8550-0aa10-2aa0_firmware7kg8550-0aa10-0aa07kg8551-0aa31-0aa07kg8551-0aa11-0aa0_firmware7kg8551-0aa11-2aa0_firmware7kg8500-0aa30-0aa0_firmware7kg8551-0aa01-0aa07kg8501-0aa02-2aa07kg8500-0aa10-2aa07kg8551-0aa31-2aa07kg8501-0aa31-2aa07kg8501-0aa12-2aa07kg8500-0aa00-0aa0_firmwareSICAM P850SICAM P855
CWE ID-CWE-287
Improper Authentication
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2022-30229
Matching Score-4
Assigner-Siemens
ShareView Details
Matching Score-4
Assigner-Siemens
CVSS Score-5.3||MEDIUM
EPSS-0.25% / 48.19%
||
7 Day CHG~0.00%
Published-14 Jun, 2022 | 09:21
Updated-03 Aug, 2024 | 06:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SICAM GridEdge Essential ARM (All versions < V2.6.6), SICAM GridEdge Essential Intel (All versions < V2.6.6), SICAM GridEdge Essential with GDS ARM (All versions < V2.6.6), SICAM GridEdge Essential with GDS Intel (All versions < V2.6.6). The affected software does not require authenticated access for privileged functions. This could allow an unauthenticated attacker to change data of an user, such as credentials, in case that user's id is known.

Action-Not Available
Vendor-Siemens AG
Product-sicam_gridedge_essentialSICAM GridEdge Essential with GDS ARMSICAM GridEdge Essential with GDS IntelSICAM GridEdge Essential ARMSICAM GridEdge Essential Intel
CWE ID-CWE-306
Missing Authentication for Critical Function
CWE ID-CWE-287
Improper Authentication
CVE-2022-26971
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-5.3||MEDIUM
EPSS-0.17% / 39.03%
||
7 Day CHG~0.00%
Published-01 Jun, 2022 | 11:34
Updated-03 Aug, 2024 | 05:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a license file upload mechanism. This upload can be executed without authentication.

Action-Not Available
Vendor-barcon/a
Product-control_room_management_suiten/a
CWE ID-CWE-306
Missing Authentication for Critical Function
  • Previous
  • 1
  • 2
  • Next
Details not found