Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2024-12985

Summary
Assigner-VulDB
Assigner Org ID-1af790b2-7ee1-4545-860a-a788eba489b5
Published At-27 Dec, 2024 | 15:00
Updated At-27 Dec, 2024 | 16:05
Rejected At-
Credits

Overtek OT-E801G passwd os command injection

A vulnerability classified as critical was found in Overtek OT-E801G OTE801G65.1.1.0. This vulnerability affects unknown code of the file /diag_ping.cmd?action=test&interface=ppp0.1&ipaddr=8.8.8.8%26%26cat%20/etc/passwd&ipversion=4&sessionKey=test. The manipulation leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:VulDB
Assigner Org ID:1af790b2-7ee1-4545-860a-a788eba489b5
Published At:27 Dec, 2024 | 15:00
Updated At:27 Dec, 2024 | 16:05
Rejected At:
▼CVE Numbering Authority (CNA)
Overtek OT-E801G passwd os command injection

A vulnerability classified as critical was found in Overtek OT-E801G OTE801G65.1.1.0. This vulnerability affects unknown code of the file /diag_ping.cmd?action=test&interface=ppp0.1&ipaddr=8.8.8.8%26%26cat%20/etc/passwd&ipversion=4&sessionKey=test. The manipulation leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Affected Products
Vendor
Overtek
Product
OT-E801G
Versions
Affected
  • OTE801G65.1.1.0
Problem Types
TypeCWE IDDescription
CWECWE-78OS Command Injection
CWECWE-77Command Injection
Type: CWE
CWE ID: CWE-78
Description: OS Command Injection
Type: CWE
CWE ID: CWE-77
Description: Command Injection
Metrics
VersionBase scoreBase severityVector
4.05.3MEDIUM
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N
3.16.3MEDIUM
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
3.06.3MEDIUM
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
2.06.5N/A
AV:N/AC:L/Au:S/C:P/I:P/A:P
Version: 4.0
Base score: 5.3
Base severity: MEDIUM
Vector:
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N
Version: 3.1
Base score: 6.3
Base severity: MEDIUM
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
Version: 3.0
Base score: 6.3
Base severity: MEDIUM
Vector:
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
Version: 2.0
Base score: 6.5
Base severity: N/A
Vector:
AV:N/AC:L/Au:S/C:P/I:P/A:P
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

reporter
c4ng4c3ir0 (VulDB User)
Timeline
EventDate
Advisory disclosed2024-12-27 00:00:00
VulDB entry created2024-12-27 01:00:00
VulDB entry last update2024-12-27 09:02:06
Event: Advisory disclosed
Date: 2024-12-27 00:00:00
Event: VulDB entry created
Date: 2024-12-27 01:00:00
Event: VulDB entry last update
Date: 2024-12-27 09:02:06
Replaced By

Rejected Reason

References
HyperlinkResource
https://vuldb.com/?id.289378
vdb-entry
https://vuldb.com/?ctiid.289378
signature
permissions-required
https://vuldb.com/?submit.462387
third-party-advisory
Hyperlink: https://vuldb.com/?id.289378
Resource:
vdb-entry
Hyperlink: https://vuldb.com/?ctiid.289378
Resource:
signature
permissions-required
Hyperlink: https://vuldb.com/?submit.462387
Resource:
third-party-advisory
▼Authorized Data Publishers (ADP)
CISA ADP Vulnrichment
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://vuldb.com/?submit.462387
exploit
Hyperlink: https://vuldb.com/?submit.462387
Resource:
exploit
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cna@vuldb.com
Published At:27 Dec, 2024 | 15:15
Updated At:27 Dec, 2024 | 16:15

A vulnerability classified as critical was found in Overtek OT-E801G OTE801G65.1.1.0. This vulnerability affects unknown code of the file /diag_ping.cmd?action=test&interface=ppp0.1&ipaddr=8.8.8.8%26%26cat%20/etc/passwd&ipversion=4&sessionKey=test. The manipulation leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Secondary4.05.3MEDIUM
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Secondary3.16.3MEDIUM
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
Secondary2.06.5MEDIUM
AV:N/AC:L/Au:S/C:P/I:P/A:P
Type: Secondary
Version: 4.0
Base score: 5.3
Base severity: MEDIUM
Vector:
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Type: Secondary
Version: 3.1
Base score: 6.3
Base severity: MEDIUM
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
Type: Secondary
Version: 2.0
Base score: 6.5
Base severity: MEDIUM
Vector:
AV:N/AC:L/Au:S/C:P/I:P/A:P
CPE Matches

Weaknesses
CWE IDTypeSource
CWE-77Secondarycna@vuldb.com
CWE-78Secondarycna@vuldb.com
CWE ID: CWE-77
Type: Secondary
Source: cna@vuldb.com
CWE ID: CWE-78
Type: Secondary
Source: cna@vuldb.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://vuldb.com/?ctiid.289378cna@vuldb.com
N/A
https://vuldb.com/?id.289378cna@vuldb.com
N/A
https://vuldb.com/?submit.462387cna@vuldb.com
N/A
https://vuldb.com/?submit.462387134c704f-9b21-4f2e-91b3-4a467353bcc0
N/A
Hyperlink: https://vuldb.com/?ctiid.289378
Source: cna@vuldb.com
Resource: N/A
Hyperlink: https://vuldb.com/?id.289378
Source: cna@vuldb.com
Resource: N/A
Hyperlink: https://vuldb.com/?submit.462387
Source: cna@vuldb.com
Resource: N/A
Hyperlink: https://vuldb.com/?submit.462387
Source: 134c704f-9b21-4f2e-91b3-4a467353bcc0
Resource: N/A

Change History

0
Information is not available yet

Similar CVEs

685Records found

CVE-2025-5571
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.14% / 34.22%
||
7 Day CHG~0.00%
Published-04 Jun, 2025 | 05:31
Updated-15 Jul, 2025 | 17:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DCS-932L setSystemAdmin os command injection

A vulnerability was found in D-Link DCS-932L 2.18.01. It has been classified as critical. Affected is the function setSystemAdmin of the file /setSystemAdmin. The manipulation of the argument AdminID leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dcs-932ldcs-932l_firmwareDCS-932L
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5443
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.56% / 67.24%
||
7 Day CHG~0.00%
Published-02 Jun, 2025 | 11:31
Updated-10 Jun, 2025 | 15:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 wirelessAdvancedHidden os command injection

A vulnerability, which was classified as critical, was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Affected is the function wirelessAdvancedHidden of the file /goform/wirelessAdvancedHidden. The manipulation of the argument ExtChSelector/24GSelector/5GSelector leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6350re6350_firmwarere6500re7000_firmwarere6300_firmwarere6500_firmwarere6300re6250_firmwarere9000_firmwarere7000re6250re9000RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5502
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.54% / 80.67%
||
7 Day CHG~0.00%
Published-03 Jun, 2025 | 14:00
Updated-06 Jun, 2025 | 17:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK X15 formMapReboot command injection

A vulnerability, which was classified as critical, has been found in TOTOLINK X15 1.0.0-B20230714.1105. Affected by this issue is the function formMapReboot of the file /boafrm/formMapReboot. The manipulation of the argument deviceMacAddr leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-TOTOLINK
Product-x15x15_firmwareX15
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-21433
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-9.9||CRITICAL
EPSS-5.47% / 89.82%
||
7 Day CHG~0.00%
Published-09 Apr, 2021 | 17:55
Updated-03 Aug, 2024 | 18:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Remote code execution on discord-recon .dirsearch and .arjun commands due to improper input validation

Discord Recon Server is a bot that allows you to do your reconnaissance process from your Discord. Remote code execution in version 0.0.1 would allow remote users to execute commands on the server resulting in serious issues. This flaw is patched in 0.0.2.

Action-Not Available
Vendor-demon1aDEMON1A
Product-discord-reconDiscord-Recon
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-21412
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-6.4||MEDIUM
EPSS-1.08% / 76.97%
||
7 Day CHG~0.00%
Published-30 Mar, 2021 | 17:40
Updated-03 Aug, 2024 | 18:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
[thi.ng/egf] Potential arbitrary code execution of `#gpg`-tagged property values

Potential for arbitrary code execution in npm package @thi.ng/egf `#gpg`-tagged property values (only if `decrypt: true` option is enabled). PR with patch has been submitted and will has been released as of v0.4.0 By default the EGF parse functions do NOT attempt to decrypt values (since GPG only available in non-browser env). However, if GPG encrypted values are used/required: 1. Perform a regex search for `#gpg`-tagged values in the EGF source file/string and check for backtick (\`) chars in the encrypted value string 2. Replace/remove them or skip parsing if present.

Action-Not Available
Vendor-\@thi.ng\/egf_projectthi-ng
Product-\@thi.ng\/egfegf
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-21530
Matching Score-4
Assigner-Dell
ShareView Details
Matching Score-4
Assigner-Dell
CVSS Score-8.3||HIGH
EPSS-0.39% / 58.94%
||
7 Day CHG~0.00%
Published-30 Apr, 2021 | 21:10
Updated-16 Sep, 2024 | 20:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell OpenManage Enterprise-Modular (OME-M) versions prior to 1.30.00 contain a security bypass vulnerability. An authenticated malicious user with low privileges may potentially exploit the vulnerability to escape from the restricted environment and gain access to sensitive information in the system, resulting in information disclosure and elevation of privilege.

Action-Not Available
Vendor-Dell Inc.
Product-openmanage_enterprise-modularOpenManage Enterprise
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2016-2056
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-60.26% / 98.21%
||
7 Day CHG~0.00%
Published-13 Apr, 2016 | 16:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

xymond in Xymon 4.1.x, 4.2.x, and 4.3.x before 4.3.25 allow remote authenticated users to execute arbitrary commands via shell metacharacters in the adduser_name argument in (1) web/useradm.c or (2) web/chpasswd.c.

Action-Not Available
Vendor-xymonn/aDebian GNU/Linux
Product-debian_linuxxymonn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-5573
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.15% / 36.71%
||
7 Day CHG~0.00%
Published-04 Jun, 2025 | 06:00
Updated-06 Jun, 2025 | 18:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DCS-932L setSystemWizard setSystemControl os command injection

A vulnerability was found in D-Link DCS-932L 2.18.01. It has been rated as critical. Affected by this issue is the function setSystemWizard/setSystemControl of the file /setSystemWizard. The manipulation of the argument AdminID leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dcs-932ldcs-932l_firmwareDCS-932L
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5504
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-6.26% / 90.55%
||
7 Day CHG~0.00%
Published-03 Jun, 2025 | 14:31
Updated-04 Jun, 2025 | 14:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK X2000R formWsc command injection

A vulnerability has been found in TOTOLINK X2000R 1.0.0-B20230726.1108 and classified as critical. This vulnerability affects unknown code of the file /boafrm/formWsc. The manipulation of the argument peerRptPin leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-TOTOLINK
Product-X2000R
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-5439
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.39% / 59.13%
||
7 Day CHG~0.00%
Published-02 Jun, 2025 | 09:31
Updated-02 Jul, 2025 | 18:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 verifyFacebookLike os command injection

A vulnerability was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. It has been rated as critical. Affected by this issue is the function verifyFacebookLike of the file /goform/verifyFacebookLike. The manipulation of the argument uid/accessToken leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re9000_firmwarere6250re7000re6300re6300_firmwarere7000_firmwarere6500_firmwarere9000re6350re6350_firmwarere6250_firmwarere6500RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5447
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.56% / 67.47%
||
7 Day CHG~0.00%
Published-02 Jun, 2025 | 13:31
Updated-02 Jul, 2025 | 01:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 ssid1MACFilter os command injection

A vulnerability was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. It has been declared as critical. This vulnerability affects the function ssid1MACFilter of the file /goform/ssid1MACFilter. The manipulation of the argument apselect_%d/newap_text_%d leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6300re6500re9000re6250re6350re7000re9000_firmwarere7000_firmwarere6500_firmwarere6300_firmwarere6350_firmwarere6250_firmwareRE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5438
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.53% / 66.40%
||
7 Day CHG~0.00%
Published-02 Jun, 2025 | 09:00
Updated-02 Jul, 2025 | 18:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 WPS command injection

A vulnerability was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. It has been declared as critical. Affected by this vulnerability is the function WPS of the file /goform/WPS. The manipulation of the argument PIN leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re9000_firmwarere6250re7000re6300re6300_firmwarere7000_firmwarere6500_firmwarere9000re6350re6350_firmwarere6250_firmwarere6500RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-5445
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.56% / 67.24%
||
7 Day CHG~0.00%
Published-02 Jun, 2025 | 12:31
Updated-10 Jun, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 RP_checkFWByBBS os command injection

A vulnerability was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001 and classified as critical. Affected by this issue is the function RP_checkFWByBBS of the file /goform/RP_checkFWByBBS. The manipulation of the argument type/ch/ssidhex/security/extch/pwd/mode/ip/nm/gw leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6350re6350_firmwarere6500re7000_firmwarere6300_firmwarere6500_firmwarere6300re6250_firmwarere9000_firmwarere7000re6250re9000RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5446
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.41% / 60.63%
||
7 Day CHG~0.00%
Published-02 Jun, 2025 | 13:00
Updated-02 Jun, 2025 | 17:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 RP_checkCredentialsByBBS os command injection

A vulnerability was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. It has been classified as critical. This affects the function RP_checkCredentialsByBBS of the file /goform/RP_checkCredentialsByBBS. The manipulation of the argument pwd leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5442
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.41% / 60.63%
||
7 Day CHG~0.00%
Published-02 Jun, 2025 | 11:00
Updated-02 Jun, 2025 | 17:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 RP_pingGatewayByBBS os command injection

A vulnerability, which was classified as critical, has been found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This issue affects the function RP_pingGatewayByBBS of the file /goform/RP_pingGatewayByBBS. The manipulation of the argument ip/nm/gw leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5606
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.07% / 76.88%
||
7 Day CHG~0.00%
Published-04 Jun, 2025 | 19:00
Updated-10 Jun, 2025 | 15:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 SetIPTVCfg formSetIptv command injection

A vulnerability was found in Tenda AC18 15.03.05.05. It has been declared as critical. This vulnerability affects the function formSetIptv of the file /goform/SetIPTVCfg. The manipulation of the argument list leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18ac18_firmwareAC18
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-5492
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.05% / 15.83%
||
7 Day CHG~0.00%
Published-03 Jun, 2025 | 10:31
Updated-15 Jul, 2025 | 17:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DI-500WF-WT /usr/sbin/jhttpd msp_info.htm sub_456DE8 command injection

A vulnerability has been found in D-Link DI-500WF-WT up to 20250511 and classified as critical. Affected by this vulnerability is the function sub_456DE8 of the file /msp_info.htm?flag=cmd of the component /usr/sbin/jhttpd. The manipulation of the argument cmd leads to command injection. The attack can be launched remotely.

Action-Not Available
Vendor-D-Link Corporation
Product-di-500wf-wt_firmwaredi-500wf-wtDI-500WF-WT
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2018-6021
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.4||HIGH
EPSS-0.55% / 67.09%
||
7 Day CHG~0.00%
Published-09 May, 2018 | 21:00
Updated-16 Sep, 2024 | 19:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Silex SD-320AN version 2.01 and prior and GE MobileLink(GEH-SD-320AN) version GEH-1.1 and prior have a system call parameter that is not properly sanitized, which may allow remote code execution.

Action-Not Available
Vendor-silextechnologyn/a
Product-geh-sd-320an_firmwaregeh-sd-320ansd-320an_firmwaresd-320ann/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2016-1468
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-8.8||HIGH
EPSS-0.67% / 70.43%
||
7 Day CHG~0.00%
Published-08 Aug, 2016 | 00:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The administrative web interface in Cisco TelePresence Video Communication Server Expressway X8.5.2 allows remote authenticated users to execute arbitrary commands via crafted fields, aka Bug ID CSCuv12531.

Action-Not Available
Vendor-n/aCisco Systems, Inc.
Product-telepresence_video_communication_servern/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2016-1141
Matching Score-4
Assigner-JPCERT/CC
ShareView Details
Matching Score-4
Assigner-JPCERT/CC
CVSS Score-4.7||MEDIUM
EPSS-0.54% / 66.57%
||
7 Day CHG~0.00%
Published-30 Jan, 2016 | 15:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

KDDI HOME SPOT CUBE devices before 2 allow remote authenticated users to execute arbitrary OS commands via unspecified vectors.

Action-Not Available
Vendor-kddin/a
Product-home_spot_cubehome_spot_cube_firmwaren/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2016-11022
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.2||HIGH
EPSS-3.73% / 87.54%
||
7 Day CHG~0.00%
Published-23 Mar, 2020 | 14:17
Updated-06 Aug, 2024 | 03:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

NETGEAR Prosafe WC9500 5.1.0.17, WC7600 5.1.0.17, and WC7520 2.5.0.35 devices allow a remote attacker to execute code with root privileges via shell metacharacters in the reqMethod parameter to login_handler.php.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-prosafe_wc7600_firmwareprosafe_wc7520_firmwareprosafe_wc9500prosafe_wc7600prosafe_wc9500_firmwareprosafe_wc7520n/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5145
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.54% / 80.63%
||
7 Day CHG~0.00%
Published-25 May, 2025 | 05:31
Updated-11 Jul, 2025 | 09:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Netcore POWER13 Query String cgi-bin command injection

A vulnerability, which was classified as critical, was found in Netcore NBR1005GPEV2, B6V2, COVER5, NAP830, NAP930, NBR100V2, NBR200V2 and POWER13 up to 20250508. This affects an unknown part of the file /www/cgi-bin/ of the component Query String Handler. The manipulation leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Netcore
Product-B6V2NAP930NBR100V2NBR1005GPEV2NBR200V2COVER5NAP830POWER13
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2016-10322
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-2.81% / 85.59%
||
7 Day CHG~0.00%
Published-10 Apr, 2017 | 18:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Synology Photo Station before 6.3-2958 allows remote authenticated guest users to execute arbitrary commands via shell metacharacters in the X-Forwarded-For HTTP header to photo/login.php.

Action-Not Available
Vendor-n/aSynology, Inc.
Product-photo_stationn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-5000
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.23% / 46.16%
||
7 Day CHG~0.00%
Published-20 May, 2025 | 21:00
Updated-12 Jun, 2025 | 16:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys FGW3000-AH/FGW3000-HK HTTP POST Request sysconf.cgi control_panel_sw command injection

A vulnerability was found in Linksys FGW3000-AH and FGW3000-HK up to 1.0.17.000000. It has been classified as critical. This affects the function control_panel_sw of the file /cgi-bin/sysconf.cgi of the component HTTP POST Request Handler. The manipulation of the argument filename leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-fgw3000-ahfgw3000-hkfgw3000-hk_firmwarefgw3000-ah_firmwareFGW3000-HKFGW3000-AH
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2018-16232
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-38.48% / 97.14%
||
7 Day CHG~0.00%
Published-17 Oct, 2018 | 14:00
Updated-05 Aug, 2024 | 10:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An authenticated command injection vulnerability exists in IPFire Firewall before 2.21 Core Update 124 in backup.cgi. This allows an authenticated user with privileges for the affected page to execute arbitrary commands.

Action-Not Available
Vendor-ipfiren/a
Product-ipfiren/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-4999
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.23% / 46.16%
||
7 Day CHG~0.00%
Published-20 May, 2025 | 21:00
Updated-12 Jun, 2025 | 16:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys FGW3000-AH/FGW3000-HK HTTP POST Request sysconf.cgi sub_4153FC command injection

A vulnerability was found in Linksys FGW3000-AH and FGW3000-HK up to 1.0.17.000000 and classified as critical. Affected by this issue is the function sub_4153FC of the file /cgi-bin/sysconf.cgi of the component HTTP POST Request Handler. The manipulation of the argument supplicant_rnd_id_en leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-fgw3000-ahfgw3000-hkfgw3000-hk_firmwarefgw3000-ah_firmwareFGW3000-HKFGW3000-AH
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-5146
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.51% / 80.48%
||
7 Day CHG~0.00%
Published-25 May, 2025 | 07:00
Updated-29 May, 2025 | 07:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Netcore NBR200V2 HTTP Header routerd passwd_set command injection

A vulnerability has been found in Netcore NBR1005GPEV2, B6V2, COVER5, NAP830, NAP930, NBR100V2 and NBR200V2 up to 20250508 and classified as critical. This vulnerability affects the function passwd_set of the file /usr/bin/routerd of the component HTTP Header Handler. The manipulation of the argument pwd leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Netcore
Product-NAP930NBR1005GPEV2B6V2COVER5NBR100V2NAP830NBR200V2
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2018-21164
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.8||MEDIUM
EPSS-1.04% / 76.52%
||
7 Day CHG~0.00%
Published-23 Apr, 2020 | 21:09
Updated-05 Aug, 2024 | 12:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R6220 before 1.1.0.64 and WNDR3700v5 before 1.1.0.54.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-r6220_firmwarer6220wndr3700wndr3700_firmwaren/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5147
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.51% / 80.48%
||
7 Day CHG~0.00%
Published-25 May, 2025 | 11:31
Updated-29 May, 2025 | 07:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Netcore NBR1005GPEV2/NBR200V2/B6V2 network_tools tools_ping command injection

A vulnerability was found in Netcore NBR1005GPEV2, NBR200V2 and B6V2 up to 20250508 and classified as critical. This issue affects the function tools_ping of the file /usr/bin/network_tools. The manipulation of the argument url leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Netcore
Product-NBR1005GPEV2NBR200V2B6V2
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2018-20727
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-3.95% / 87.90%
||
7 Day CHG~0.00%
Published-17 Jan, 2019 | 02:00
Updated-05 Aug, 2024 | 12:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Multiple command injection vulnerabilities in NeDi before 1.7Cp3 allow authenticated users to execute code on the server side via the flt parameter to Nodes-Traffic.php, the dv parameter to Devices-Graph.php, or the tit parameter to drawmap.php.

Action-Not Available
Vendor-nedin/a
Product-nedin/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-12358
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.50% / 80.40%
||
7 Day CHG+0.32%
Published-09 Dec, 2024 | 04:31
Updated-10 Dec, 2024 | 23:34
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
WeiYe-Jing datax-web add os command injection

A vulnerability was found in WeiYe-Jing datax-web 2.1.1. It has been classified as critical. This affects an unknown part of the file /api/job/add/. The manipulation of the argument glueSource leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-datax-web_projectWeiYe-Jingweiye-jing
Product-datax-webdatax-webdatax-web
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2018-15887
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-7.80% / 91.62%
||
7 Day CHG~0.00%
Published-27 Aug, 2018 | 15:00
Updated-05 Aug, 2024 | 10:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Main_Analysis_Content.asp in ASUS DSL-N12E_C1 1.1.2.3_345 is prone to Authenticated Remote Command Execution, which allows a remote attacker to execute arbitrary OS commands via service parameters, such as shell metacharacters in the destIP parameter of a cmdMethod=ping request.

Action-Not Available
Vendor-n/aASUS (ASUSTeK Computer Inc.)
Product-dsl-n12e_c1dsl-n12e_c1_firmwaren/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2016-0326
Matching Score-4
Assigner-IBM Corporation
ShareView Details
Matching Score-4
Assigner-IBM Corporation
CVSS Score-8.8||HIGH
EPSS-0.89% / 74.67%
||
7 Day CHG~0.00%
Published-22 Oct, 2016 | 01:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

IBM Rational Quality Manager (RQM) and Rational Collaborative Lifecycle Management 3.0.1.6 before iFix8, 4.x before 4.0.7 iFix11, 5.x before 5.0.2 iFix17, and 6.x before 6.0.1 ifix3 allow remote authenticated users to execute arbitrary OS commands via a crafted "HTML request."

Action-Not Available
Vendor-n/aIBM Corporation
Product-rational_collaborative_lifecycle_managementrational_quality_managern/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-12350
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-2.13% / 83.50%
||
7 Day CHG+0.45%
Published-09 Dec, 2024 | 00:31
Updated-11 Dec, 2024 | 17:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
JFinalCMS Template TemplateController.java update command injection

A vulnerability was found in JFinalCMS 1.0. It has been rated as critical. Affected by this issue is the function update of the file \src\main\java\com\cms\controller\admin\TemplateController.java of the component Template Handler. The manipulation of the argument content leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-jwillbern/ajfinalcms_project
Product-jfinalcmsJFinalCMSjfinalcms
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2016-0325
Matching Score-4
Assigner-IBM Corporation
ShareView Details
Matching Score-4
Assigner-IBM Corporation
CVSS Score-6.3||MEDIUM
EPSS-0.47% / 63.62%
||
7 Day CHG~0.00%
Published-24 Nov, 2016 | 19:41
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

IBM Rational Collaborative Lifecycle Management 3.0.1.6 before iFix8, 4.0 before 4.0.7 iFix11, 5.0 before 5.0.2 iFix18, and 6.0 before 6.0.2 iFix5; Rational Quality Manager 3.0.1.6 before iFix8, 4.0 before 4.0.7 iFix11, 5.0 before 5.0.2 iFix18, and 6.0 before 6.0.2 iFix5; Rational Team Concert 3.0.1.6 before iFix8, 4.0 before 4.0.7 iFix11, 5.0 before 5.0.2 iFix18, and 6.0 before 6.0.2 iFix5; Rational DOORS Next Generation 4.0 before 4.0.7 iFix11, 5.0 before 5.0.2 iFix18, and 6.0 before 6.0.2 iFix5; Rational Engineering Lifecycle Manager 4.x before 4.0.7 iFix11, 5.0 before 5.0.2 iFix18, and 6.0 before 6.0.2 iFix5; Rational Rhapsody Design Manager 4.0 before 4.0.7 iFix11, 5.0 before 5.0.2 iFix18, and 6.0 before 6.0.2 iFix5; and Rational Software Architect Design Manager 4.0 before 4.0.7 iFix11, 5.0 before 5.0.2 iFix18, and 6.0 before 6.0.2 iFix5 allow remote authenticated users to execute arbitrary OS commands via a crafted request.

Action-Not Available
Vendor-n/aIBM Corporation
Product-rational_team_concertn/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2018-12692
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-7.48% / 91.41%
||
7 Day CHG~0.00%
Published-23 Jun, 2018 | 18:00
Updated-16 Sep, 2024 | 16:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

TP-Link TL-WA850RE Wi-Fi Range Extender with hardware version 5 allows remote authenticated users to execute arbitrary commands via shell metacharacters in the wps_setup_pin parameter to /data/wps.setup.json.

Action-Not Available
Vendor-n/aTP-Link Systems Inc.
Product-tl-wa850retl-wa850re_firmwaren/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-10697
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-66.82% / 98.48%
||
7 Day CHG+0.95%
Published-02 Nov, 2024 | 12:00
Updated-05 Apr, 2025 | 07:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC6 API Endpoint WriteFacMac formWriteFacMac command injection

A vulnerability has been found in Tenda AC6 15.03.05.19 and classified as critical. Affected by this vulnerability is the function formWriteFacMac of the file /goform/WriteFacMac of the component API Endpoint. The manipulation of the argument mac leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac6ac6_firmwareAC6ac6_firmware
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-10919
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-3.45% / 87.07%
||
7 Day CHG~0.00%
Published-06 Nov, 2024 | 16:00
Updated-08 Nov, 2024 | 21:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
didi Super-Jacoco triggerUnitCover os command injection

A vulnerability has been found in didi Super-Jacoco 1.0 and classified as critical. Affected by this vulnerability is an unknown functionality of the file /cov/triggerUnitCover. The manipulation of the argument uuid leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-didididididi
Product-super-jacocoSuper-Jacocosuper_jacoco
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-10966
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-2.50% / 84.75%
||
7 Day CHG-0.25%
Published-07 Nov, 2024 | 18:00
Updated-16 Dec, 2024 | 23:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK X18 cstecgi.cgi os command injection

A vulnerability, which was classified as critical, has been found in TOTOLINK X18 9.1.0cu.2024_B20220329. Affected by this issue is some unknown functionality of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument enable leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-x18x18_firmwareX18x18
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2018-19031
Matching Score-4
Assigner-40f8fa2f-7875-43d0-a30e-e901a5537754
ShareView Details
Matching Score-4
Assigner-40f8fa2f-7875-43d0-a30e-e901a5537754
CVSS Score-8.8||HIGH
EPSS-3.82% / 87.68%
||
7 Day CHG~0.00%
Published-04 Nov, 2019 | 14:42
Updated-05 Aug, 2024 | 11:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A command injection vulnerability exists when the authorized user passes crafted parameter to background process in the router. This affects 360 router series products (360 Safe Router P0,P1,P2,P3,P4), the affected version is V2.0.61.58897.

Action-Not Available
Vendor-360360 Security Technology, Inc.
Product-safe_router_p1_firmwaresafe_router_p3safe_router_p4_firmwaresafe_router_p4safe_router_p1safe_router_p2_firmwaresafe_router_p0_firmwaresafe_router_p0safe_router_p2safe_router_p3_firmware360 Safe Router
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2018-15153
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-75.98% / 98.87%
||
7 Day CHG~0.00%
Published-15 Aug, 2018 | 17:00
Updated-05 Aug, 2024 | 09:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

OS command injection occurring in versions of OpenEMR before 5.0.1.4 allows a remote authenticated attacker to execute arbitrary commands by making a crafted request to interface/main/daemon_frame.php after modifying the "hylafax_server" global variable in interface/super/edit_globals.php.

Action-Not Available
Vendor-n/aOpenEMR Foundation, Inc
Product-openemrn/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2015-7769
Matching Score-4
Assigner-JPCERT/CC
ShareView Details
Matching Score-4
Assigner-JPCERT/CC
CVSS Score-6.3||MEDIUM
EPSS-0.59% / 68.34%
||
7 Day CHG~0.00%
Published-19 Feb, 2016 | 19:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

baserCMS 3.0.2 through 3.0.8 allows remote authenticated users to execute arbitrary OS commands via unspecified vectors.

Action-Not Available
Vendor-basercmsn/a
Product-basercmsn/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2018-15155
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-7.55% / 91.45%
||
7 Day CHG~0.00%
Published-15 Aug, 2018 | 17:00
Updated-05 Aug, 2024 | 09:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

OS command injection occurring in versions of OpenEMR before 5.0.1.4 allows a remote authenticated attacker to execute arbitrary commands by making a crafted request to interface/fax/fax_dispatch.php after modifying the "hylafax_enscript" global variable in interface/super/edit_globals.php.

Action-Not Available
Vendor-n/aOpenEMR Foundation, Inc
Product-openemrn/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-11046
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.16% / 77.72%
||
7 Day CHG+0.30%
Published-10 Nov, 2024 | 03:00
Updated-13 Nov, 2024 | 21:01
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DI-8003 upgrade_filter.asp upgrade_filter_asp os command injection

A vulnerability was found in D-Link DI-8003 16.07.16A1. It has been classified as critical. Affected is the function upgrade_filter_asp of the file /upgrade_filter.asp. The manipulation of the argument path leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-di-8003_firmwaredi-8003DI-8003
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-4849
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.92% / 75.00%
||
7 Day CHG~0.00%
Published-18 May, 2025 | 02:31
Updated-24 May, 2025 | 00:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK N300RH cstecgi.cgi CloudACMunualUpdateUserdata command injection

A vulnerability was found in TOTOLINK N300RH 6.1c.1390_B20191101. It has been rated as critical. Affected by this issue is the function CloudACMunualUpdateUserdata of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument url leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-n300rh_firmwaren300rhN300RH
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2018-15481
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.76% / 72.28%
||
7 Day CHG~0.00%
Published-21 Aug, 2018 | 16:00
Updated-05 Aug, 2024 | 09:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Improper input sanitization within the restricted administration shell on UCOPIA Wireless Appliance devices using firmware version 5.1.x before 5.1.13 allows authenticated remote attackers to escape the shell and escalate their privileges by adding a LocalCommand to the SSH configuration file in the user home folder.

Action-Not Available
Vendor-ucopian/a
Product-wireless_appliancewireless_appliance_firmwaren/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-4851
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.92% / 75.00%
||
7 Day CHG~0.00%
Published-18 May, 2025 | 03:31
Updated-24 May, 2025 | 01:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK N300RH cstecgi.cgi setUploadUserData command injection

A vulnerability classified as critical was found in TOTOLINK N300RH 6.1c.1390_B20191101. This vulnerability affects the function setUploadUserData of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument FileName leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-n300rh_firmwaren300rhN300RH
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2015-8988
Matching Score-4
Assigner-Intel Corporation
ShareView Details
Matching Score-4
Assigner-Intel Corporation
CVSS Score-8.8||HIGH
EPSS-0.58% / 68.03%
||
7 Day CHG~0.00%
Published-14 Mar, 2017 | 22:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Unquoted executable path vulnerability in Client Management and Gateway components in McAfee (now Intel Security) ePO Deep Command (eDC) 2.2 and 2.1 allows authenticated users to execute a command of their choice via dropping a malicious file for the path.

Action-Not Available
Vendor-McAfee, LLCIntel Corporation
Product-epo_deep_commandePO Deep Command (eDC)
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4729
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-2.87% / 85.76%
||
7 Day CHG~0.00%
Published-15 May, 2025 | 23:31
Updated-20 Jun, 2025 | 14:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK A3002R/A3002RU HTTP POST Request formMapDelDevice command injection

A vulnerability was found in TOTOLINK A3002R and A3002RU 3.0.0-B20230809.1615. It has been declared as critical. Affected by this vulnerability is an unknown functionality of the file /boafrm/formMapDelDevice of the component HTTP POST Request Handler. The manipulation of the argument macstr leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-a3002rua3002ru_firmwarea3002ra3002r_firmwareA3002RA3002RU
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-10435
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.97% / 82.78%
||
7 Day CHG+0.36%
Published-28 Oct, 2024 | 00:31
Updated-28 Oct, 2024 | 13:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
didi Super-Jacoco triggerEnvCov command injection

A vulnerability was found in didi Super-Jacoco 1.0. It has been declared as critical. This vulnerability affects unknown code of the file /cov/triggerEnvCov. The manipulation of the argument uuid leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-didididi
Product-Super-Jacocosuper_jacoco
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
  • Previous
  • 1
  • 2
  • 3
  • 4
  • 5
  • ...
  • 13
  • 14
  • Next
Details not found