CVE-2024-22044

Summary
Assigner-siemens
Assigner Org ID-cec7a2ec-15b4-4faf-bd53-b40f371f3a77
Published At-12 Mar, 2024 | 10:21
Updated At-26 Aug, 2024 | 18:02
Rejected At-
Credits

A vulnerability has been identified in SENTRON 3KC ATC6 Expansion Module Ethernet (3KC9000-8TL75) (All versions). Affected devices expose an unused, unstable http service at port 80/tcp on the Modbus-TCP Ethernet. This could allow an attacker on the same Modbus network to create a denial of service condition that forces the device to reboot.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:siemens
Assigner Org ID:cec7a2ec-15b4-4faf-bd53-b40f371f3a77
Published At:12 Mar, 2024 | 10:21
Updated At:26 Aug, 2024 | 18:02
Rejected At:
▼CVE Numbering Authority (CNA)

A vulnerability has been identified in SENTRON 3KC ATC6 Expansion Module Ethernet (3KC9000-8TL75) (All versions). Affected devices expose an unused, unstable http service at port 80/tcp on the Modbus-TCP Ethernet. This could allow an attacker on the same Modbus network to create a denial of service condition that forces the device to reboot.

Affected Products
Vendor
Siemens AGSiemens
Product
SENTRON 3KC ATC6 Expansion Module Ethernet
Default Status
unknown
Versions
Affected
  • From 0 before * (custom)
Problem Types
TypeCWE IDDescription
CWECWE-912CWE-912: Hidden Functionality
Type: CWE
CWE ID: CWE-912
Description: CWE-912: Hidden Functionality
Metrics
VersionBase scoreBase severityVector
3.17.5HIGH
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Version: 3.1
Base score: 7.5
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://cert-portal.siemens.com/productcert/html/ssa-918992.html
N/A
Hyperlink: https://cert-portal.siemens.com/productcert/html/ssa-918992.html
Resource: N/A
▼Authorized Data Publishers (ADP)
1. CISA ADP Vulnrichment
Affected Products
Vendor
Siemens AGsiemens
Product
sentron_3kc_act6
CPEs
  • cpe:2.3:h:siemens:sentron_3kc_act6:*:*:*:*:*:*:*:*
Default Status
unknown
Versions
Affected
  • From 0 before * (custom)
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
2. CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://cert-portal.siemens.com/productcert/html/ssa-918992.html
x_transferred
Hyperlink: https://cert-portal.siemens.com/productcert/html/ssa-918992.html
Resource:
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:productcert@siemens.com
Published At:12 Mar, 2024 | 11:15
Updated At:12 Mar, 2024 | 12:40

A vulnerability has been identified in SENTRON 3KC ATC6 Expansion Module Ethernet (3KC9000-8TL75) (All versions). Affected devices expose an unused, unstable http service at port 80/tcp on the Modbus-TCP Ethernet. This could allow an attacker on the same Modbus network to create a denial of service condition that forces the device to reboot.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Secondary3.17.5HIGH
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Type: Secondary
Version: 3.1
Base score: 7.5
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
CPE Matches

Weaknesses
CWE IDTypeSource
CWE-912Primaryproductcert@siemens.com
CWE ID: CWE-912
Type: Primary
Source: productcert@siemens.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://cert-portal.siemens.com/productcert/html/ssa-918992.htmlproductcert@siemens.com
N/A
Hyperlink: https://cert-portal.siemens.com/productcert/html/ssa-918992.html
Source: productcert@siemens.com
Resource: N/A

Change History

0
Information is not available yet

Similar CVEs

196Records found

CVE-2019-12259
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-30.05% / 96.49%
||
7 Day CHG~0.00%
Published-09 Aug, 2019 | 18:05
Updated-04 Aug, 2024 | 23:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Wind River VxWorks 6.6, 6.7, 6.8, 6.9 and vx7 has an array index error in the IGMPv3 client component. There is an IPNET security vulnerability: DoS via NULL dereference in IGMP parsing.

Action-Not Available
Vendor-windriverbeldenn/aSiemens AGSonicWall Inc.
Product-hirschmann_rsp20ruggedcom_win7025_firmwarehirschmann_ees25sonicoshirschmann_grs1030hirschmann_grs1142ruggedcom_win7018_firmwarehirschmann_rspe32hirschmann_grs1130garrettcom_magnum_dx940ehirschmann_rspe35hirschmann_eesx20hirschmann_rspe37ruggedcom_win7018hirschmann_grs10429410_power_meter_firmwareruggedcom_win7000siprotec_5_firmwareruggedcom_win7200hirschmann_rsp35garrettcom_magnum_dx940e_firmwarevxworkshirschmann_msp40hirschmann_octopus_os39810_power_meterhirschmann_rsp309410_power_meter9810_power_meter_firmwarehirschmann_dragon_mach4000hirschmann_dragon_mach4500hirschmann_msp32hirschmann_rsp25hirschmann_rail_switch_power_smarthirschmann_eesx30hirschmann_grs1020hirschmann_rail_switch_power_litehirschmann_eagle20hirschmann_eagle30hirschmann_hiosruggedcom_win7025hirschmann_rspe30hirschmann_eagle_oneruggedcom_win7200_firmwaresiprotec_5hirschmann_ees20hirschmann_red25ruggedcom_win7000_firmwarehirschmann_msp30hirschmann_grs1120n/a
CWE ID-CWE-476
NULL Pointer Dereference
CVE-2019-10923
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.47% / 63.54%
||
7 Day CHG~0.00%
Published-10 Oct, 2019 | 13:49
Updated-11 Feb, 2025 | 10:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation.

Action-Not Available
Vendor-Siemens AG
Product-simatic_s7-300_cpu_313simatic_winac_rtx_\(f\)cp1604_firmwaresinamics_s150_firmwaresimatic_et_200mdk_standard_ethernet_controllersinamics_dcm_firmwaresimatic_s7-400_v6sinamics_gm150simatic_et_200ecopn_firmwaresinamics_gl150_firmwaresimatic_s7-400_pn_v7_firmwaresimatic_s7-400_dp_v7sinamics_gl150sinumerik_840d_slscalance_x-200irtsimatic_s7-300_cpu_firmwaresimatic_s7-400_pn_v7sinamics_gh150cp1616simatic_et_200s_firmwaresimatic_s7-300_cpu_316-2_dp_firmwaresinamics_dcmsimatic_pn\/pn_coupler_6es7158-3ad01-0xa0sinamics_sm120scalance_x-200irt_firmwaresinamics_g120simatic_s7-300_cpu_315-2_dpsimatic_s7-300_cpu_315_firmwaresimotion_firmwaresimotionsinumerik_828dcp1616_firmwaresinamics_sl150_firmwaresinamics_s150ek-ertec_200ek-ertec_200_firmwaresinamics_dcp_firmwaresimatic_s7-300_cpusimatic_s7-300_cpu_314_firmwaresimatic_s7-400_v6_firmwarecp1604simatic_s7-300_cpu_314ek-ertec_200p_firmwaresimatic_et_200m_firmwaresimatic_s7-300_cpu_318-2_firmwaresimatic_s7-300_cpu_313_firmwaresimatic_et_200ssimatic_s7-400_dp_v7_firmwaredk_standard_ethernet_controller_firmwaresimatic_s7-300_cpu_318-2sinamics_s110sinamics_gm150_firmwaresinamics_g150sinamics_g130simatic_s7-300_cpu_315-2_dp_firmwaresimatic_s7-300_cpu_315simatic_s7-300_cpu_312_ifm_firmwaresinamics_g110mek-ertec_200psinamics_g110m_firmwaresinamics_gh150_firmwaresinamics_dcpsinamics_sl150simatic_et_200ecopnsimatic_pn\/pn_coupler_6es7158-3ad01-0xa0_firmwaresimatic_s7-300_cpu_314_ifmsimatic_s7-300_cpu_312_ifmsimatic_s7-300_cpu_314_ifm_firmwaresimatic_s7-300_cpu_316-2_dpsinamics_sm120_firmwaresinamics_g150_firmwaresinamics_s120sinamics_g130_firmwaresinamics_s120_firmwaresimatic_winac_rtx_\(f\)_firmwaresinamics_s110_firmwaresinamics_g120_firmwareSINAMICS G120 V4.7 Control Unit (incl. SIPLUS variants)SINAMICS SM120 V4.7 Control UnitSIPLUS ET 200SP IM 155-6 PN STSIMATIC ET 200MP IM 155-5 PN STSIPLUS ET 200S IM 151-8 PN/DP CPUSIPLUS S7-300 CPU 315-2 PN/DPSIMATIC S7-300 CPU 317T-3 PN/DPSINUMERIK 828DSINAMICS GL150 V4.7 Control UnitSIPLUS S7-300 CPU 317F-2 PN/DPSIPLUS ET 200SP IM 155-6 PN ST BA TX RAILSIPLUS ET 200MP IM 155-5 PN HF T1 RAILSIPLUS ET 200SP IM 155-6 PN HFDevelopment/Evaluation Kits for PROFINET IO: EK-ERTEC 200SIMATIC ET200ecoPN: IO-Link MasterSIMATIC ET200ecoPN, 8AI RTD/TC 8xM12SIMATIC ET 200SP IM 155-6 PN HFSIMATIC ET200ecoPN, 8DI, DC24V, 8xM12SIPLUS S7-300 CPU 314C-2 PN/DPSCALANCE X-200IRT family (incl. SIPLUS NET variants)SIPLUS ET 200SP IM 155-6 PN HF T1 RAILSIMATIC PN/PN Coupler (incl. SIPLUS NET variants)SIMATIC S7-400 CPU 416-3 PN/DP V7SIMATIC S7-300 CPU 315F-2 PN/DPSINUMERIK 840D slSIMATIC ET 200pro IM 154-8 PN/DP CPUSIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12SINAMICS G150SINAMICS GH150 V4.7 Control UnitSIMATIC S7-300 CPU 314C-2 PN/DPSINAMICS S120 V4.7 Control Unit and CBE20 (incl. SIPLUS variants)SIMATIC ET200ecoPN, 4AO U/I 4xM12SIMATIC S7-400 CPU 414-3 PN/DP V7SINAMICS DCPSIPLUS S7-400 CPU 414-3 PN/DP V7SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12SIMATIC WinAC RTX 2010SIMATIC ET 200pro IM 154-3 PN HFSIMATIC ET 200M (incl. SIPLUS variants)SIPLUS S7-400 CPU 416-3 PN/DP V7SIMATIC ET 200S IM 151-8 PN/DP CPUSIMATIC S7-400 CPU 416F-3 PN/DP V7SINAMICS GM150 V4.7 Control UnitSIMATIC CP 1616Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet ControllerSIPLUS ET 200SP IM 155-6 PN ST TX RAILSIMATIC S7-400 CPU 414F-3 PN/DP V7SIMATIC ET 200S IM 151-8F PN/DP CPUSIMATIC ET 200pro IM 154-8F PN/DP CPUDevelopment/Evaluation Kits for PROFINET IO: EK-ERTEC 200PSIMATIC S7-300 CPU 315-2 PN/DPSIMATIC ET 200MP IM 155-5 PN HFSIMATIC S7-300 CPU 319F-3 PN/DPSIPLUS ET 200MP IM 155-5 PN ST TX RAILSIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12SIMATIC S7-300 CPU 317-2 PN/DPSIMATIC ET 200SP IM 155-6 PN ST BASIMATIC S7-300 CPU 317TF-3 PN/DPSIMATIC ET 200SP IM 155-6 PN STSIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)SIPLUS S7-300 CPU 317-2 PN/DPSIPLUS S7-300 CPU 315F-2 PN/DPSIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12SIMATIC ET 200pro IM 154-4 PN HFSIPLUS ET 200S IM 151-8F PN/DP CPUSIPLUS ET 200SP IM 155-6 PN ST BASIMATIC CP 1604SIMATIC S7-400 CPU 412-2 PN V7SIPLUS ET 200MP IM 155-5 PN HFSINAMICS DCMSIMOTIONSIMATIC S7-300 CPU 319-3 PN/DPSIMATIC ET200S (incl. SIPLUS variants)SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12SIMATIC S7-300 CPU 317F-2 PN/DPSIMATIC WinAC RTX F 2010SINAMICS S150SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12SINAMICS G110M V4.7 Control UnitSINAMICS G130SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12SIMATIC ET 200pro IM 154-8FX PN/DP CPUSIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12SIPLUS ET 200MP IM 155-5 PN STSINAMICS SL150 V4.7 Control UnitSIMATIC S7-300 CPU 315T-3 PN/DPSINAMICS S110 Control Unit
CWE ID-CWE-400
Uncontrolled Resource Consumption
CVE-2019-10931
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.19% / 40.77%
||
7 Day CHG~0.00%
Published-11 Jul, 2019 | 21:17
Updated-04 Aug, 2024 | 22:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions ), DIGSI 5 engineering software (All versions < V7.90), SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7UT86, 7UT87 and 7VE85 with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions < V7.90), SIPROTEC 5 device types 7SS85 and 7KE85 (All versions < V8.01), SIPROTEC 5 device types with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.59), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.59). Specially crafted packets sent to port 443/TCP could cause a Denial of Service condition.

Action-Not Available
Vendor-Siemens AG
Product-6md857sa867sj826md867um857sj857ut867ss85siprotec_5_digsi_device_driver7sa877vk877ve856md897ut877sa827ut857sl827sd867ke857sl867sd827sk857sk827ut827sd877sj867sl87digsi_5_engineering_softwareSIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7UT86, 7UT87 and 7VE85 with CPU variants CP300 and CP100 and the respective Ethernet communication modulesAll other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modulesSIPROTEC 5 device types with CPU variants CP200 and the respective Ethernet communication modulesDIGSI 5 engineering softwareSIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modulesSIPROTEC 5 device types 7SS85 and 7KE85
CWE ID-CWE-248
Uncaught Exception
CVE-2019-10937
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.77% / 72.46%
||
7 Day CHG~0.00%
Published-13 Sep, 2019 | 16:38
Updated-04 Aug, 2024 | 22:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC TDC CP51M1 (All versions < V1.1.7). An attacker with network access to the device could cause a Denial-of-Service condition by sending a specially crafted UDP packet. The vulnerability affects the UDP communication of the device. The security vulnerability could be exploited without authentication. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-simatic_tdc_cp51m1_firmwaresimatic_tdc_cp51m1SIMATIC TDC CP51M1
CWE ID-CWE-20
Improper Input Validation
CVE-2019-10936
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-1.99% / 82.88%
||
7 Day CHG~0.00%
Published-10 Oct, 2019 | 00:00
Updated-04 Aug, 2024 | 22:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Affected devices improperly handle large amounts of specially crafted UDP packets. This could allow an unauthenticated remote attacker to trigger a denial of service condition.

Action-Not Available
Vendor-Siemens AG
Product-simatic_s7-1500_cpu_1511csimatic_s7-1500_cpudk_standard_ethernet_controllersimatic_s7-400h_v6_firmwaresimatic_et_200sp_im_155-6_pn_st_firmwaresimatic_et_200ecopn_firmwaresimatic_s7-1200_cpu_1212csimatic_s7-1500s_cpusinamics_gl150_firmwaresimatic_s7-400_pn_v7_firmwaresimatic_s7-400_dp_v7sinamics_gl150simatic_s7-300_cpu_firmwaresimatic_s7-1500_cpu_1512c_firmwaresimatic_s7-400_pn_v7simatic_hmi_comfort_panels_22\"simatic_et_200sp_im_155-6_pn\/2_hfsimatic_et_200pro_firmwaresimatic_profinet_driver_firmwaresimatic_s7-410_v8_firmwaresinamics_dcmsimatic_hmi_comfort_outdoor_panels_7\"sinamics_sm120simatic_et_200mp_im_155-5_pn_hfsimatic_hmi_ktp_mobile_panelssimatic_et_200mp_im_155-5_pn_basimatic_et_200sp_im_155-6_pn_stsinumerik_828dsimatic_hmi_comfort_panels_4\"sinamics_s150ek-ertec_200simatic_hmi_comfort_outdoor_panels_15\"simatic_s7-1200_cpu_1214c_firmwaresimatic_s7-300_cpusimatic_s7-300_cpu_314_firmwaresimatic_s7-1200_cpu_1211c_firmwaresimatic_et_200sp_im_155-6_pn_basimatic_s7-1200_cpu_1214csimatic_s7-400_v6_firmwaresimatic_et_200sp_im_155-6_pn_hssimatic_s7-300_cpu_314ek-ertec_200p_firmwaresimatic_s7-300_cpu_318-2_firmwaresimatic_s7-300_cpu_313_firmwaresimatic_et_200sp_im_155-6_pn_hfsinamics_gm150_firmwaresimatic_hmi_comfort_outdoor_panels_7\"_firmwaresinamics_g150simatic_s7-300_cpu_312_ifm_firmwaresimatic_et_200mp_im_155-5_pn_hf_firmwaresimatic_et_200sp_im_155-6_pn\/2_hf_firmwaresinamics_sl150simatic_s7-1500t_cpu_firmwaresimatic_et_200mp_im_155-5_pn_stsimatic_et_200ecopnsimatic_et_200alsimatic_s7-300_cpu_312_ifmsimatic_s7-1500_cpu_1518simatic_s7-300_cpu_316-2_dpsimatic_pn\/pn_couplersinamics_s120simatic_s7-1500_cpu_1518_firmwaresimatic_cfu_pa_firmwaresimatic_et_200prosinumerik_840d_slsimatic_s7-300_cpu_313simatic_et_200sp_im_155-6_pn_hasimatic_cfu_pasinamics_s150_firmwaresimatic_et_200msinamics_dcm_firmwaresimatic_s7-400_v6sinamics_gm150simatic_et_200sp_im_155-6_pn_ba_firmwaresimatic_s7-400h_v6simatic_et_200al_firmwaresimatic_hmi_comfort_panels_4\"_firmwaresimatic_s7-1500t_cpusimatic_s7-410_v8simatic_s7-1200_cpu_1212c_firmwaresimatic_et_200s_firmwaresimatic_s7-300_cpu_316-2_dp_firmwaresimatic_et_200mp_im_155-5_pn_st_firmwaresimatic_hmi_ktp_mobile_panels_firmwaresimatic_et_200sp_im_155-6_pn_ha_firmwaresimatic_hmi_comfort_outdoor_panels_15\"_firmwaresimatic_s7-1500_cpu_1512csimatic_s7-300_cpu_315_firmwaresimatic_s7-300_cpu_315-2_dpsinamics_g120simatic_s7-1200_cpusinamics_sl150_firmwaresimatic_hmi_comfort_panels_22\"_firmwareek-ertec_200_firmwaresinamics_dcp_firmwaresimatic_winac_rtx_\(f\)_2010simatic_s7-1500_cpu_firmwaresimatic_et_200sp_im_155-6_pn\/3_hfsimatic_s7-1500s_cpu_firmwaresimatic_et_200m_firmwaresimatic_et_200ssimatic_profinet_driversimatic_s7-400_dp_v7_firmwaredk_standard_ethernet_controller_firmwaresimatic_s7-300_cpu_318-2simatic_s7-1500_cpu_1511c_firmwaresinamics_s110simatic_et_200sp_im_155-6_pn_hs_firmwaresimatic_et_200mp_im_155-5_pn_ba_firmwaresimatic_s7-300_cpu_315-2_dp_firmwaresimatic_pn\/pn_coupler_firmwaresimatic_s7-300_cpu_315sinamics_g110msinamics_g130ek-ertec_200psinamics_g110m_firmwaresinamics_dcpsimatic_s7-1200_cpu_firmwaresimatic_s7-300_cpu_314_ifmsimatic_s7-1200_cpu_1211csimatic_et_200sp_im_155-6_pn\/3_hf_firmwaresimatic_s7-300_cpu_314_ifm_firmwaresinamics_sm120_firmwaresinamics_g150_firmwaresimatic_et_200sp_im_155-6_pn_hf_firmwaresinamics_g130_firmwaresinamics_s120_firmwaresimatic_winac_rtx_\(f\)_firmwaresinamics_s110_firmwaresinamics_g120_firmwareSINAMICS GM150 V4.7 Control UnitSINUMERIK 840D slSIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12SIMATIC ET200ecoPN, 4AO U/I 4xM12SIPLUS ET 200MP IM 155-5 PN HF T1 RAILSINAMICS S110 Control UnitSIMATIC ET 200SP IM 155-6 PN HFSIMATIC S7-400 CPU 414F-3 PN/DP V7SIPLUS NET PN/PN CouplerSIPLUS S7-300 CPU 315F-2 PN/DPSIMATIC S7-300 CPU 317F-2 PN/DPSINAMICS DCMSIPLUS ET 200SP IM 155-6 PN HFSIMATIC ET 200SP IM 155-6 PN STSIMATIC S7-300 CPU 315F-2 PN/DPSIMATIC HMI Comfort Panels (incl. SIPLUS variants)SIMATIC S7-300 CPU 317-2 PN/DPSIMATIC S7-300 CPU 317TF-3 PN/DPSIMATIC ET 200SP IM 155-6 PN HSSIMATIC ET200ecoPN: IO-Link MasterSINAMICS S150 Control UnitSINAMICS G150 Control UnitSIMATIC PN/PN CouplerSIMATIC S7-300 CPU 317T-3 PN/DPSIMATIC ET 200SP IM 155-6 PN BASIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12SIMATIC S7-400 CPU 416F-3 PN/DP V7SIPLUS ET 200SP IM 155-6 PN HF T1 RAILSIPLUS ET 200SP IM 155-6 PN ST TX RAILSIMATIC ET 200SP IM 155-6 PN/2 HFSINAMICS G110M V4.7 PN Control UnitSIMATIC S7-300 CPU 319-3 PN/DPSIMATIC ET 200pro IM 154-8F PN/DP CPUSIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)SIMATIC ET 200SP IM 155-6 PN ST BASIMATIC ET 200S IM 151-8 PN/DP CPUSIMATIC CFU PASIMATIC ET 200MP IM 155-5 PN HFSIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)SINAMICS DCPSINAMICS G130 V4.7 Control UnitSIMATIC ET 200S IM 151-8F PN/DP CPUSIMATIC ET200ecoPN, 16DI, DC24V, 8xM12SIMATIC HMI Comfort Outdoor Panels (incl. SIPLUS variants)SIMATIC ET 200pro IM 154-4 PN HFSIMATIC S7-1500 Software ControllerSIMATIC ET 200MP IM 155-5 PN STSINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants)SIPLUS S7-300 CPU 317-2 PN/DPSIPLUS S7-400 CPU 414-3 PN/DP V7SIMATIC TDC CPU555SINAMICS GH150 V4.7 Control UnitSIMATIC ET200S (incl. SIPLUS variants)SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12SIMATIC S7-400 CPU 416-3 PN/DP V7SIPLUS S7-300 CPU 317F-2 PN/DPSIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)SIMATIC ET 200SP IM 155-6 PN/3 HFSIPLUS S7-300 CPU 314C-2 PN/DPSIPLUS ET 200S IM 151-8F PN/DP CPUSIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12SIMATIC TDC CP51M1SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12SIMATIC WinAC RTX 2010SIMATIC ET 200MP IM 155-5 PN BASIMATIC ET 200pro IM 154-8FX PN/DP CPUSIMATIC S7-1200 CPU family (incl. SIPLUS variants)SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12SIMATIC HMI KTP Mobile PanelsDevelopment/Evaluation Kits for PROFINET IO: EK-ERTEC 200PSIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)SIPLUS ET 200SP IM 155-6 PN ST BASIMATIC ET 200pro IM 154-3 PN HFSIPLUS ET 200SP IM 155-6 PN HF TX RAILSIMATIC S7-300 CPU 314C-2 PN/DPDevelopment/Evaluation Kits for PROFINET IO: EK-ERTEC 200SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12SIMATIC PROFINET DriverDevelopment/Evaluation Kits for PROFINET IO: DK Standard Ethernet ControllerSINUMERIK 828DSIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12SIPLUS S7-300 CPU 315-2 PN/DPSIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12SIMATIC S7-300 CPU 315-2 PN/DPSIPLUS ET 200SP IM 155-6 PN ST BA TX RAILSIMATIC S7-300 CPU 319F-3 PN/DPSINAMICS GL150 V4.7 Control UnitSIMATIC ET 200M (incl. SIPLUS variants)SIMATIC ET 200pro IM 154-8 PN/DP CPUSIPLUS S7-400 CPU 416-3 PN/DP V7SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)SIPLUS ET 200MP IM 155-5 PN STSIPLUS ET 200S IM 151-8 PN/DP CPUSIMATIC WinAC RTX F 2010SIMATIC S7-400 CPU 414-3 PN/DP V7SIMATIC ET 200AL IM 157-1 PNSIMATIC ET200ecoPN, 8DI, DC24V, 8xM12SIPLUS ET 200SP IM 155-6 PN STSIPLUS ET 200MP IM 155-5 PN ST TX RAILSIMATIC S7-400 CPU 412-2 PN V7SINAMICS SM120 V4.7 Control UnitSIPLUS ET 200MP IM 155-5 PN HFSINAMICS SL150 V4.7 Control UnitSINAMICS G120 V4.7 PN Control Unit (incl. SIPLUS variants)SIMATIC S7-300 CPU 315T-3 PN/DPSIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)simatic_winac_rtx_\(f\)_2010simatic_tdc_cpu555_firmwaresimatic_et_200sp_firmwaresimatic_tdc_cp51m1_firmwaresiplus_s7-300_cpu_314simatic_s7-1500_cpusimatic_et200ecopn_firmwaresimatic_cfu_pasimatic_s7-400_h_v6_firmwareek-ertec_200p_firmwaresimatic_et_200m_firmwaresinamics_gm150simatic_profinet_driversimatic_s7-300_cpu_315f-2_dp_firmwaredk_standard_ethernet_controller_firmwaresimatic_s7-400_cpu_416-3_pn\/dpsinamics_gl150simatic_s7-300_cpu_317-2_dp_firmwaresimatic_et_200al_firmwaresimatic_s7-400_pn\/dp_v6_firmwaresinamics_s110sinamics_g150simatic_winac_rtx_2010simatic_s7-300_cpu_315-2_dp_firmwaresinamics_g130sinamics_g110msinamics_gh150simatic_et_200mp_firmwaresinamics_dcpsinamics_sl150simatic_et_200s_firmwaresimatic_et_200pro_firmwaresimatic_s7-410_cpu_firmwaresimatic_pn\/pn_coupler_6es7158-3ad01-0xa0sinamics_dcmsimatic_hmi_comfort_outdoor_panelssimatic_s7-400_cpu_412-2_pnsinamics_sm120sinamics_g120simatic_et200s_firmwaresimatic_s7-400_cpu_414-3_pn\/dpsinumerik_828dsimatic_s7-1200_cpusimatic_s7-300_cpu_319-3_pn\/dp_firmwaresinamics_s120ek-ertec_200_firmwaresimatic_s7-1500_controllersimatic_s7-300_cpu_314_firmwaresimatic_s7-300_cpu_317-2_pn\/dp_firmwaresinumerik_840d_sl
CWE ID-CWE-400
Uncontrolled Resource Consumption
CVE-2019-10953
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.5||HIGH
EPSS-0.72% / 71.54%
||
7 Day CHG~0.00%
Published-17 Apr, 2019 | 14:02
Updated-04 Aug, 2024 | 22:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets.

Action-Not Available
Vendor-wagon/aABBPhoenix Contact GmbH & Co. KGSiemens AG
Product-ethernet_firmwarebacnet\/ip6es7211-1ae40-0xb0modicon_m221_firmwareknx_ip_firmwareknx_ipethernet6es7314-6eh04-0ab0modicon_m221pm554-tp-eth_firmware6es7314-6eh04-0ab0_firmware6ed1052-1cc01-0ba8pm554-tp-eth6es7211-1ae40-0xb0_firmwarepfc100_firmwarepfc100ilc_151_eth_firmwarebacnet\/ip_firmware6ed1052-1cc01-0ba8_firmwareilc_151_ethABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers
CWE ID-CWE-400
Uncontrolled Resource Consumption
CWE ID-CWE-770
Allocation of Resources Without Limits or Throttling
CVE-2022-27194
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.16% / 37.46%
||
7 Day CHG~0.00%
Published-12 Apr, 2022 | 09:07
Updated-03 Aug, 2024 | 05:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC PCS neo (Administration Console) (All versions < V3.1 SP1), SINETPLAN (All versions), TIA Portal (V15, V15.1, V16 and V17). The affected system cannot properly process specially crafted packets sent to port 8888/tcp. A remote attacker could exploit this vulnerability to cause a Denial-of-Service condition. The affected devices must be restarted manually.

Action-Not Available
Vendor-Siemens AG
Product-simatic_pcs_neototally_integrated_automation_portalsinetplanSIMATIC PCS neo (Administration Console)SINETPLANTIA Portal
CWE ID-CWE-400
Uncontrolled Resource Consumption
CVE-2022-26648
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.2||HIGH
EPSS-0.87% / 74.30%
||
7 Day CHG~0.00%
Published-12 Jul, 2022 | 10:06
Updated-21 Apr, 2025 | 13:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT PRO (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2P IRT (All versions < V5.5.2), SCALANCE X202-2P IRT PRO (All versions < V5.5.2), SCALANCE X204-2 (All versions < V5.2.6), SCALANCE X204-2FM (All versions < V5.2.6), SCALANCE X204-2LD (All versions < V5.2.6), SCALANCE X204-2LD TS (All versions < V5.2.6), SCALANCE X204-2TS (All versions < V5.2.6), SCALANCE X204IRT (All versions < V5.5.2), SCALANCE X204IRT (All versions < V5.5.2), SCALANCE X204IRT PRO (All versions < V5.5.2), SCALANCE X206-1 (All versions < V5.2.6), SCALANCE X206-1LD (All versions < V5.2.6), SCALANCE X208 (All versions < V5.2.6), SCALANCE X208PRO (All versions < V5.2.6), SCALANCE X212-2 (All versions < V5.2.6), SCALANCE X212-2LD (All versions < V5.2.6), SCALANCE X216 (All versions < V5.2.6), SCALANCE X224 (All versions < V5.2.6), SCALANCE XF201-3P IRT (All versions < V5.5.2), SCALANCE XF202-2P IRT (All versions < V5.5.2), SCALANCE XF204 (All versions < V5.2.6), SCALANCE XF204-2 (All versions < V5.2.6), SCALANCE XF204-2BA IRT (All versions < V5.5.2), SCALANCE XF204IRT (All versions < V5.5.2), SCALANCE XF206-1 (All versions < V5.2.6), SCALANCE XF208 (All versions < V5.2.6). Affected devices do not properly validate the GET parameter XNo of incoming HTTP requests. This could allow an unauthenticated remote attacker to crash affected devices.

Action-Not Available
Vendor-Siemens AG
Product-scalance_xf206-1_firmwarescalance_xf201-3p_irtscalance_x208_pro_firmwarescalance_x212-2ldscalance_x201-3p_irtscalance_x204-2ldscalance_xf208scalance_x201-3p_irt_firmwarescalance_x202-2p_irt_pro_firmwarescalance_xf204irtscalance_xf204-2ba_irt_firmwarescalance_x206-1scalance_x204-2ld_ts_firmwarescalance_x204irtscalance_x201-3p_irt_proscalance_x204-2fmscalance_x204-2ld_tsscalance_x208scalance_x200-4p_irtscalance_x204irt_pro_firmwarescalance_x202-2irtscalance_x202-2p_irtscalance_x204-2scalance_x224scalance_x206-1_firmwarescalance_x204-2_firmwarescalance_xf204-2scalance_xf206-1scalance_x202-2p_irt_firmwarescalance_x206-1ld_firmwarescalance_x212-2ld_firmwarescalance_x212-2scalance_xf204_firmwarescalance_x204-2ts_firmwarescalance_xf204-2ba_irtscalance_x216_firmwarescalance_x204-2ld_firmwarescalance_x212-2_firmwarescalance_xf208_firmwarescalance_xf202-2p_irt_firmwarescalance_x208_firmwarescalance_x208_proscalance_xf204-2_firmwarescalance_x202-2p_irt_proscalance_x202-2irt_firmwarescalance_xf202-2p_irtscalance_x200-4p_irt_firmwarescalance_x204irt_proscalance_x216scalance_xf201-3p_irt_firmwarescalance_x204-2fm_firmwarescalance_x204-2tsscalance_xf204irt_firmwarescalance_x201-3p_irt_pro_firmwarescalance_x204irt_firmwarescalance_xf204scalance_x206-1ldscalance_x224_firmwareSCALANCE XF201-3P IRTSCALANCE XF204-2BA IRTSCALANCE X202-2P IRTSCALANCE X202-2P IRT PROSCALANCE X204-2TSSCALANCE X206-1SCALANCE XF204IRTSCALANCE X204IRTSCALANCE X200-4P IRTSCALANCE X224SCALANCE XF208SCALANCE X208SCALANCE XF204-2SCALANCE X204-2LD TSSCALANCE X208PROSCALANCE X204-2LDSCALANCE X204-2SCALANCE X216SCALANCE X212-2LDSCALANCE X201-3P IRT PROSCALANCE XF206-1SCALANCE X201-3P IRTSCALANCE X206-1LDSCALANCE X212-2SCALANCE XF202-2P IRTSCALANCE X204-2FMSCALANCE XF204SCALANCE X202-2IRTSCALANCE X204IRT PRO
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2022-26335
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-2.87% / 85.74%
||
7 Day CHG~0.00%
Published-12 Apr, 2022 | 09:07
Updated-03 Aug, 2024 | 05:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices do not properly validate the URI of incoming HTTP GET requests. This could allow an unauthenticated remote attacker to crash affected devices.

Action-Not Available
Vendor-Siemens AG
Product-scalance_x308-2m_ts_firmwarescalance_x307-3_firmwarescalance_xr324-12mscalance_x310fescalance_x310fe_firmwarescalance_xr324-4m_eecscalance_x308-2ldscalance_x320-1fe_firmwaresiplus_net_scalance_x308-2scalance_xr324-4m_poe_firmwarescalance_x308-2scalance_x307-2eecscalance_xr324-4m_eec_firmwarescalance_x308-2_firmwarescalance_x304-2fe_firmwarescalance_xr324-12m_ts_firmwarescalance_x306-1ldfe_firmwarescalance_x307-2eec_firmwarescalance_x320-1-2ldfesiplus_net_scalance_x308-2_firmwarescalance_x308-2lh_firmwarescalance_x302-7eec_firmwarescalance_x308-2lhscalance_x307-3ld_firmwarescalance_x310scalance_x320-1-2ldfe_firmwarescalance_xr324-12m_firmwarescalance_x308-2m_poe_firmwarescalance_x308-2lh\+scalance_x310_firmwarescalance_x308-2m_poescalance_x308-2lh\+_firmwarescalance_x308-2ld_firmwarescalance_xr324-12m_tsscalance_x308-2m_tsscalance_x308-2m_firmwarescalance_x320-1fescalance_x408-2scalance_xr324-4m_poescalance_x306-1ldfescalance_x307-3ldscalance_x308-2mscalance_x408-2_firmwarescalance_x307-3scalance_x304-2fescalance_xr324-4m_poe_tsscalance_xr324-4m_poe_ts_firmwarescalance_x302-7eecSCALANCE XR324-12M TS (24V)SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)SCALANCE XR324-4M PoE (24V, ports on rear)SCALANCE XR324-4M EEC (24V, ports on front)SCALANCE XR324-12M (230V, ports on rear)SCALANCE X307-2 EEC (2x 24V, coated)SCALANCE XR324-4M PoE TS (24V, ports on front)SCALANCE X307-3SCALANCE X308-2MSCALANCE XR324-12M (24V, ports on rear)SCALANCE X308-2SCALANCE X308-2M PoESCALANCE X310FESCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)SCALANCE X308-2LH+SCALANCE X302-7 EEC (24V, coated)SCALANCE X307-2 EEC (230V, coated)SCALANCE X307-3LDSCALANCE X308-2LHSCALANCE XR324-4M EEC (24V, ports on rear)SCALANCE XR324-4M PoE (24V, ports on front)SCALANCE X302-7 EEC (2x 230V)SCALANCE X408-2SIPLUS NET SCALANCE X308-2SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)SCALANCE XR324-4M PoE (230V, ports on rear)SCALANCE X302-7 EEC (230V)SCALANCE X307-2 EEC (24V, coated)SCALANCE X307-2 EEC (2x 230V, coated)SCALANCE X302-7 EEC (2x 24V, coated)SCALANCE X308-2LDSCALANCE X307-2 EEC (24V)SCALANCE X304-2FESCALANCE X310SCALANCE X307-2 EEC (2x 24V)SCALANCE X307-2 EEC (230V)SCALANCE XR324-12M (24V, ports on front)SCALANCE X320-1 FESCALANCE X302-7 EEC (2x 24V)SCALANCE X306-1LD FESCALANCE X308-2M TSSCALANCE XR324-4M PoE (230V, ports on front)SCALANCE X307-2 EEC (2x 230V)SCALANCE X302-7 EEC (24V)SCALANCE X302-7 EEC (230V, coated)SCALANCE X302-7 EEC (2x 230V, coated)SCALANCE X320-1-2LD FESCALANCE XR324-4M EEC (2x 24V, ports on rear)SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)SCALANCE XR324-12M (230V, ports on front)SCALANCE XR324-4M EEC (2x 24V, ports on front)
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2018-4832
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.57% / 67.60%
||
7 Day CHG~0.00%
Published-24 Apr, 2018 | 17:00
Updated-05 Aug, 2024 | 05:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in OpenPCS 7 V7.1 and earlier (All versions), OpenPCS 7 V8.0 (All versions), OpenPCS 7 V8.1 (All versions < V8.1 Upd5), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd1), SIMATIC BATCH V7.1 and earlier (All versions), SIMATIC BATCH V8.0 (All versions < V8.0 SP1 Upd21), SIMATIC BATCH V8.1 (All versions < V8.1 SP1 Upd16), SIMATIC BATCH V8.2 (All versions < V8.2 Upd10), SIMATIC BATCH V9.0 (All versions < V9.0 SP1), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions < 15 SP1), SIMATIC PCS 7 V7.1 and earlier (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP1), SIMATIC Route Control V7.1 and earlier (All versions), SIMATIC Route Control V8.0 (All versions), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions < V9.0 Upd1), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Upd2), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Upd5), SIMATIC WinCC V7.2 and earlier (All versions < WinCC 7.2 Upd 15), SIMATIC WinCC V7.3 (All versions < WinCC 7.3 Upd 16), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 4), SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). Specially crafted messages sent to the RPC service of the affected products could cause a Denial-of-Service condition on the remote and local communication functionality of the affected products. A reboot of the system is required to recover the remote and local communication functionality. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sppa-t3000_application_serveropenpcs_7simatic_winccsimatic_pcs_7simatic_route_controlsimatic_net_pc_softwaresimatic_net_pcsimatic_wincc_runtime_professionalsimatic_batchSIMATIC NET PC Software V14SIMATIC BATCH V7.1 and earlierSIMATIC NET PC Software V15SIMATIC BATCH V8.1SIMATIC WinCC V7.3SIMATIC PCS 7 V9.0SIMATIC Route Control V8.0OpenPCS 7 V9.0OpenPCS 7 V8.2SIMATIC WinCC V7.4OpenPCS 7 V8.1SIMATIC BATCH V8.2SIMATIC WinCC Runtime Professional V14SPPA-T3000 Application ServerSIMATIC WinCC V7.2 and earlierSIMATIC Route Control V8.2SIMATIC WinCC Runtime Professional V13SIMATIC PCS 7 V8.0SIMATIC PCS 7 V7.1 and earlierSIMATIC PCS 7 V8.2SIMATIC Route Control V8.1OpenPCS 7 V7.1 and earlierSIMATIC Route Control V9.0SIMATIC BATCH V9.0SIMATIC PCS 7 V8.1OpenPCS 7 V8.0SIMATIC Route Control V7.1 and earlierSIMATIC BATCH V8.0
CWE ID-CWE-20
Improper Input Validation
CVE-2018-5391
Matching Score-8
Assigner-CERT/CC
ShareView Details
Matching Score-8
Assigner-CERT/CC
CVSS Score-7.5||HIGH
EPSS-1.73% / 81.70%
||
7 Day CHG~0.00%
Published-06 Sep, 2018 | 21:00
Updated-05 Aug, 2024 | 05:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
The Linux kernel, versions 3.9+, IP implementation is vulnerable to denial of service conditions with low rates of specially modified packets

The Linux kernel, versions 3.9+, is vulnerable to a denial of service attack with low rates of specially modified packets targeting IP fragment re-assembly. An attacker may cause a denial of service condition by sending specially crafted IP fragments. Various vulnerabilities in IP fragmentation have been discovered and fixed over the years. The current vulnerability (CVE-2018-5391) became exploitable in the Linux kernel with the increase of the IP fragment reassembly queue size.

Action-Not Available
Vendor-Debian GNU/LinuxRed Hat, Inc.Canonical Ltd.F5, Inc.Siemens AGLinux Kernel Organization, IncMicrosoft Corporation
Product-ubuntu_linuxbig-ip_webacceleratorbig-ip_application_acceleration_managerenterprise_linux_server_euswindows_8.1big-ip_policy_enforcement_managerenterprise_linux_server_ausscalance_sc-600_firmwaresimatic_rf188_firmwareruggedcom_rm1224_firmwarebig-ip_local_traffic_managersimatic_net_cp_1243-7_lte_uswindows_10simatic_net_cp_1243-7_lte_us_firmwarescalance_w700_ieee_802.11a\/b\/g\/nsinema_remote_connect_serverenterprise_linux_workstationsimatic_net_cp_1243-1simatic_net_cp_1243-7_lte_eu_firmwaresimatic_rf185c_firmwarescalance_s615_firmwaresimatic_net_cp_1543sp-1enterprise_linux_desktopsimatic_net_cp_1543-1scalance_m-800_firmwaresimatic_net_cp_1242-7_firmwaresimatic_net_cp_1542sp-1_firmwarebig-ip_domain_name_systemsimatic_net_cp_1543sp-1_firmwarescalance_w1700_ieee_802.11ac_firmwareruggedcom_rox_iisimatic_net_cp_1542sp-1big-ip_edge_gatewaydebian_linuxlinux_kernelsimatic_net_cp_1543-1_firmwarescalance_sc-600simatic_net_cp_1242-7simatic_net_cp_1243-1_firmwarewindows_server_2008simatic_net_cp_1542sp-1_irc_firmwareenterprise_linux_serverwindows_server_2016windows_server_2012simatic_rf188big-ip_fraud_protection_serviceruggedcom_rox_ii_firmwarescalance_w700_ieee_802.11a\/b\/g\/n_firmwaresimatic_rf186c_firmwaresimatic_net_cp_1542sp-1_ircbig-ip_application_security_managerruggedcom_rm1224simatic_rf185cscalance_s615simatic_rf186cisimatic_net_cp_1243-8_ircbig-ip_access_policy_managersimatic_net_cp_1243-8_irc_firmwaresimatic_rf186ci_firmwaresimatic_rf188ci_firmwaresinema_remote_connect_server_firmwarewindows_rt_8.1big-ip_global_traffic_managerbig-ip_analyticssimatic_rf186cbig-ip_link_controllerscalance_w1700_ieee_802.11acwindows_7scalance_m-800enterprise_linux_server_tusbig-ip_advanced_firewall_managersimatic_rf188cisimatic_net_cp_1243-7_lte_euKernel
CWE ID-CWE-400
Uncontrolled Resource Consumption
CWE ID-CWE-20
Improper Input Validation
CVE-2024-43647
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.40% / 59.90%
||
7 Day CHG~0.00%
Published-10 Sep, 2024 | 09:36
Updated-10 Sep, 2024 | 14:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC S7-200 SMART CPU CR40 (6ES7288-1CR40-0AA0) (All versions), SIMATIC S7-200 SMART CPU CR60 (6ES7288-1CR60-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR20 (6ES7288-1SR20-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR20 (6ES7288-1SR20-0AA1) (All versions), SIMATIC S7-200 SMART CPU SR30 (6ES7288-1SR30-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR30 (6ES7288-1SR30-0AA1) (All versions), SIMATIC S7-200 SMART CPU SR40 (6ES7288-1SR40-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR40 (6ES7288-1SR40-0AA1) (All versions), SIMATIC S7-200 SMART CPU SR60 (6ES7288-1SR60-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR60 (6ES7288-1SR60-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST20 (6ES7288-1ST20-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST20 (6ES7288-1ST20-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST30 (6ES7288-1ST30-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST30 (6ES7288-1ST30-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST40 (6ES7288-1ST40-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST40 (6ES7288-1ST40-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST60 (6ES7288-1ST60-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST60 (6ES7288-1ST60-0AA1) (All versions). Affected devices do not properly handle TCP packets with an incorrect structure. This could allow an unauthenticated remote attacker to cause a denial of service condition. To restore normal operations, the network cable of the device needs to be unplugged and re-plugged.

Action-Not Available
Vendor-Siemens AG
Product-SIMATIC S7-200 SMART CPU CR40SIMATIC S7-200 SMART CPU ST60SIMATIC S7-200 SMART CPU SR40SIMATIC S7-200 SMART CPU ST30SIMATIC S7-200 SMART CPU SR30SIMATIC S7-200 SMART CPU SR60SIMATIC S7-200 SMART CPU CR60SIMATIC S7-200 SMART CPU SR20SIMATIC S7-200 SMART CPU ST40SIMATIC S7-200 SMART CPU ST20simatic_s7-200_smart_cpu_st60
CWE ID-CWE-400
Uncontrolled Resource Consumption
CVE-2018-25032
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-0.09% / 26.20%
||
7 Day CHG~0.00%
Published-25 Mar, 2022 | 00:00
Updated-21 Aug, 2025 | 20:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

zlib before 1.2.12 allows memory corruption when deflating (i.e., when compressing) if the input has many distant matches.

Action-Not Available
Vendor-azulzlibgoton/aNetApp, Inc.Fedora ProjectDebian GNU/LinuxSparkle MotionSiemens AGMicrosoft CorporationPython Software FoundationApple Inc.MariaDB Foundation
Product-h410cmacospythonhci_compute_nodeh500s_firmwareh300s_firmwarescalance_sc642-2c_firmwaremac_os_xscalance_sc646-2c_firmwareh700s_firmwaremariadbscalance_sc622-2c_firmwaremanagement_services_for_element_softwarescalance_sc632-2c_firmwarezlibh410sh410s_firmwarenokogiriontap_select_deploy_administration_utilityscalance_sc636-2cfedorawindowsscalance_sc642-2cgotoassisth300sscalance_sc626-2czuluscalance_sc626-2c_firmwarescalance_sc636-2c_firmwareh410c_firmwarescalance_sc646-2cactive_iq_unified_managerscalance_sc622-2ce-series_santricity_os_controllerh700sdebian_linuxscalance_sc632-2ch500soncommand_workflow_automationn/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-39158
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-5.3||MEDIUM
EPSS-0.29% / 51.46%
||
7 Day CHG~0.00%
Published-13 Sep, 2022 | 00:00
Updated-12 Aug, 2025 | 12:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM i800, RUGGEDCOM i800NC, RUGGEDCOM i801, RUGGEDCOM i801NC, RUGGEDCOM i802, RUGGEDCOM i802NC, RUGGEDCOM i803, RUGGEDCOM i803NC, RUGGEDCOM M2100, RUGGEDCOM M2100F, RUGGEDCOM M2100NC, RUGGEDCOM M2200, RUGGEDCOM M2200F, RUGGEDCOM M2200NC, RUGGEDCOM M969, RUGGEDCOM M969F, RUGGEDCOM M969NC, RUGGEDCOM RMC30, RUGGEDCOM RMC30NC, RUGGEDCOM RMC8388 V4.X, RUGGEDCOM RMC8388 V5.X, RUGGEDCOM RMC8388NC V4.X, RUGGEDCOM RMC8388NC V5.X, RUGGEDCOM RP110, RUGGEDCOM RP110NC, RUGGEDCOM RS1600, RUGGEDCOM RS1600F, RUGGEDCOM RS1600FNC, RUGGEDCOM RS1600NC, RUGGEDCOM RS1600T, RUGGEDCOM RS1600TNC, RUGGEDCOM RS400, RUGGEDCOM RS400F, RUGGEDCOM RS400NC, RUGGEDCOM RS401, RUGGEDCOM RS401NC, RUGGEDCOM RS416, RUGGEDCOM RS416F, RUGGEDCOM RS416NC, RUGGEDCOM RS416NCv2 V4.X, RUGGEDCOM RS416NCv2 V5.X, RUGGEDCOM RS416P, RUGGEDCOM RS416PF, RUGGEDCOM RS416PNC, RUGGEDCOM RS416PNCv2 V4.X, RUGGEDCOM RS416PNCv2 V5.X, RUGGEDCOM RS416Pv2 V4.X, RUGGEDCOM RS416Pv2 V5.X, RUGGEDCOM RS416v2 V4.X, RUGGEDCOM RS416v2 V5.X, RUGGEDCOM RS8000, RUGGEDCOM RS8000A, RUGGEDCOM RS8000ANC, RUGGEDCOM RS8000H, RUGGEDCOM RS8000HNC, RUGGEDCOM RS8000NC, RUGGEDCOM RS8000T, RUGGEDCOM RS8000TNC, RUGGEDCOM RS900, RUGGEDCOM RS900 (32M) V4.X, RUGGEDCOM RS900 (32M) V5.X, RUGGEDCOM RS900F, RUGGEDCOM RS900G, RUGGEDCOM RS900G (32M) V4.X, RUGGEDCOM RS900G (32M) V5.X, RUGGEDCOM RS900GF, RUGGEDCOM RS900GNC, RUGGEDCOM RS900GNC(32M) V4.X, RUGGEDCOM RS900GNC(32M) V5.X, RUGGEDCOM RS900GP, RUGGEDCOM RS900GPF, RUGGEDCOM RS900GPNC, RUGGEDCOM RS900L, RUGGEDCOM RS900LNC, RUGGEDCOM RS900M-GETS-C01, RUGGEDCOM RS900M-GETS-XX, RUGGEDCOM RS900M-STND-C01, RUGGEDCOM RS900M-STND-XX, RUGGEDCOM RS900MNC-GETS-C01, RUGGEDCOM RS900MNC-GETS-XX, RUGGEDCOM RS900MNC-STND-XX, RUGGEDCOM RS900MNC-STND-XX-C01, RUGGEDCOM RS900NC, RUGGEDCOM RS900NC(32M) V4.X, RUGGEDCOM RS900NC(32M) V5.X, RUGGEDCOM RS900W, RUGGEDCOM RS910, RUGGEDCOM RS910L, RUGGEDCOM RS910LNC, RUGGEDCOM RS910NC, RUGGEDCOM RS910W, RUGGEDCOM RS920L, RUGGEDCOM RS920LNC, RUGGEDCOM RS920W, RUGGEDCOM RS930L, RUGGEDCOM RS930LNC, RUGGEDCOM RS930W, RUGGEDCOM RS940G, RUGGEDCOM RS940GF, RUGGEDCOM RS940GNC, RUGGEDCOM RS969, RUGGEDCOM RS969NC, RUGGEDCOM RSG2100, RUGGEDCOM RSG2100 (32M) V4.X, RUGGEDCOM RSG2100 (32M) V5.X, RUGGEDCOM RSG2100F, RUGGEDCOM RSG2100NC, RUGGEDCOM RSG2100NC(32M) V4.X, RUGGEDCOM RSG2100NC(32M) V5.X, RUGGEDCOM RSG2100P, RUGGEDCOM RSG2100P (32M) V4.X, RUGGEDCOM RSG2100P (32M) V5.X, RUGGEDCOM RSG2100PF, RUGGEDCOM RSG2100PNC, RUGGEDCOM RSG2100PNC (32M) V4.X, RUGGEDCOM RSG2100PNC (32M) V5.X, RUGGEDCOM RSG2200, RUGGEDCOM RSG2200F, RUGGEDCOM RSG2200NC, RUGGEDCOM RSG2288 V4.X, RUGGEDCOM RSG2288 V5.X, RUGGEDCOM RSG2288NC V4.X, RUGGEDCOM RSG2288NC V5.X, RUGGEDCOM RSG2300 V4.X, RUGGEDCOM RSG2300 V5.X, RUGGEDCOM RSG2300F, RUGGEDCOM RSG2300NC V4.X, RUGGEDCOM RSG2300NC V5.X, RUGGEDCOM RSG2300P V4.X, RUGGEDCOM RSG2300P V5.X, RUGGEDCOM RSG2300PF, RUGGEDCOM RSG2300PNC V4.X, RUGGEDCOM RSG2300PNC V5.X, RUGGEDCOM RSG2488 V4.X, RUGGEDCOM RSG2488 V5.X, RUGGEDCOM RSG2488F, RUGGEDCOM RSG2488NC V4.X, RUGGEDCOM RSG2488NC V5.X, RUGGEDCOM RSG907R, RUGGEDCOM RSG908C, RUGGEDCOM RSG909R, RUGGEDCOM RSG910C, RUGGEDCOM RSG920P V4.X, RUGGEDCOM RSG920P V5.X, RUGGEDCOM RSG920PNC V4.X, RUGGEDCOM RSG920PNC V5.X, RUGGEDCOM RSL910, RUGGEDCOM RSL910NC, RUGGEDCOM RST2228, RUGGEDCOM RST2228P, RUGGEDCOM RST916C, RUGGEDCOM RST916P. Affected devices improperly handle partial HTTP requests which makes them vulnerable to slowloris attacks. This could allow a remote attacker to create a denial of service condition that persists until the attack ends.

Action-Not Available
Vendor-Siemens AG
Product-ruggedcom_rsg2100_\(32m\)ruggedcom_rsg2300pruggedcom_rsg907rruggedcom_rst916pruggedcom_rsg910cruggedcom_rsl910ruggedcom_rs900_\(32m\)ruggedcom_rosruggedcom_rsg920pruggedcom_rsg2300ruggedcom_rs416v2ruggedcom_rst916cruggedcom_rst2228ruggedcom_rst2228pruggedcom_rmc8388ruggedcom_rsg909rruggedcom_rsg908cruggedcom_rs416pv2ruggedcom_rsg2488ruggedcom_rsg2288ruggedcom_rs900g_\(32m\)RUGGEDCOM RS8000RUGGEDCOM RS900LRUGGEDCOM RSG2300 V4.XRUGGEDCOM RS900MNC-STND-XX-C01RUGGEDCOM RSG920P V4.XRUGGEDCOM RS401NCRUGGEDCOM RSG2100PNC (32M) V4.XRUGGEDCOM RS920LNCRUGGEDCOM RS910LRUGGEDCOM RS930WRUGGEDCOM RSG2100NC(32M) V5.XRUGGEDCOM RSG2100 (32M) V5.XRUGGEDCOM RSG2288NC V5.XRUGGEDCOM RS416Pv2 V4.XRUGGEDCOM RS1600RUGGEDCOM i801NCRUGGEDCOM RS940GRUGGEDCOM RSG2100NC(32M) V4.XRUGGEDCOM i800NCRUGGEDCOM RS910RUGGEDCOM RSG908CRUGGEDCOM RS8000NCRUGGEDCOM RS400FRUGGEDCOM RS900NC(32M) V4.XRUGGEDCOM RS920LRUGGEDCOM RMC8388 V4.XRUGGEDCOM RS8000HRUGGEDCOM RS900LNCRUGGEDCOM RS8000TRUGGEDCOM RS910NCRUGGEDCOM RS416PFRUGGEDCOM RS900GRUGGEDCOM M2100FRUGGEDCOM RS900M-STND-XXRUGGEDCOM RS900WRUGGEDCOM RMC8388 V5.XRUGGEDCOM RS900MNC-STND-XXRUGGEDCOM RSG2100PNC (32M) V5.XRUGGEDCOM RSG910CRUGGEDCOM RSG2300PFRUGGEDCOM RSG2288 V4.XRUGGEDCOM RS1600NCRUGGEDCOM RS969RUGGEDCOM RS900 (32M) V4.XRUGGEDCOM RSG909RRUGGEDCOM RS416FRUGGEDCOM RS900GPFRUGGEDCOM RSG2100PRUGGEDCOM RS930LNCRUGGEDCOM RS416PRUGGEDCOM RSG920P V5.XRUGGEDCOM RSG2200NCRUGGEDCOM RS8000HNCRUGGEDCOM RSG2300PNC V5.XRUGGEDCOM RSG2288 V5.XRUGGEDCOM RS1600FRUGGEDCOM RS416NCRUGGEDCOM RS930LRUGGEDCOM RSG907RRUGGEDCOM RSG2300P V5.XRUGGEDCOM RS910WRUGGEDCOM RSG2300 V5.XRUGGEDCOM RS940GNCRUGGEDCOM RS900GNCRUGGEDCOM RSG2100P (32M) V4.XRUGGEDCOM RMC8388NC V5.XRUGGEDCOM RS940GFRUGGEDCOM RS910LNCRUGGEDCOM RSG2288NC V4.XRUGGEDCOM RSG2488 V5.XRUGGEDCOM RMC30RUGGEDCOM RS900GFRUGGEDCOM RS8000ANCRUGGEDCOM RMC8388NC V4.XRUGGEDCOM RS1600TRUGGEDCOM M969FRUGGEDCOM RS900G (32M) V5.XRUGGEDCOM RS400NCRUGGEDCOM RS900MNC-GETS-C01RUGGEDCOM RS900M-GETS-C01RUGGEDCOM RSG2488NC V4.XRUGGEDCOM M2200FRUGGEDCOM RP110RUGGEDCOM i801RUGGEDCOM RS416v2 V4.XRUGGEDCOM RS416NCv2 V4.XRUGGEDCOM RS8000TNCRUGGEDCOM RSG2300P V4.XRUGGEDCOM RS416v2 V5.XRUGGEDCOM RS920WRUGGEDCOM RS900FRUGGEDCOM M2200RUGGEDCOM RS900MNC-GETS-XXRUGGEDCOM RSG2300NC V5.XRUGGEDCOM RS900GNC(32M) V4.XRUGGEDCOM RS900RUGGEDCOM RSG2100RUGGEDCOM M969NCRUGGEDCOM RS416PNCRUGGEDCOM RS1600FNCRUGGEDCOM RS400RUGGEDCOM RS900NC(32M) V5.XRUGGEDCOM RS1600TNCRUGGEDCOM RS900G (32M) V4.XRUGGEDCOM M969RUGGEDCOM RS416PNCv2 V4.XRUGGEDCOM M2200NCRUGGEDCOM RS8000ARUGGEDCOM i803RUGGEDCOM RSG2100PNCRUGGEDCOM RSG920PNC V5.XRUGGEDCOM RSG2100NCRUGGEDCOM RSG2488FRUGGEDCOM RP110NCRUGGEDCOM RSG2200RUGGEDCOM RSG2488NC V5.XRUGGEDCOM RSL910NCRUGGEDCOM RS969NCRUGGEDCOM RS416RUGGEDCOM RST2228PRUGGEDCOM i800RUGGEDCOM RS900M-STND-C01RUGGEDCOM RS900M-GETS-XXRUGGEDCOM RST916PRUGGEDCOM RS416PNCv2 V5.XRUGGEDCOM RS416NCv2 V5.XRUGGEDCOM RSG2100 (32M) V4.XRUGGEDCOM RSL910RUGGEDCOM RSG2100PFRUGGEDCOM RS900GPRUGGEDCOM RST916CRUGGEDCOM RS900GPNCRUGGEDCOM RSG2100FRUGGEDCOM RSG2488 V4.XRUGGEDCOM i802RUGGEDCOM RS900GNC(32M) V5.XRUGGEDCOM RST2228RUGGEDCOM RS401RUGGEDCOM RSG2300NC V4.XRUGGEDCOM RSG920PNC V4.XRUGGEDCOM i802NCRUGGEDCOM i803NCRUGGEDCOM M2100RUGGEDCOM RSG2300FRUGGEDCOM RSG2300PNC V4.XRUGGEDCOM RS900NCRUGGEDCOM RS416Pv2 V5.XRUGGEDCOM RMC30NCRUGGEDCOM RS900 (32M) V5.XRUGGEDCOM RSG2200FRUGGEDCOM M2100NCRUGGEDCOM RSG2100P (32M) V5.X
CWE ID-CWE-400
Uncontrolled Resource Consumption
CVE-2018-16890
Matching Score-8
Assigner-Red Hat, Inc.
ShareView Details
Matching Score-8
Assigner-Red Hat, Inc.
CVSS Score-5.4||MEDIUM
EPSS-0.89% / 74.50%
||
7 Day CHG~0.00%
Published-06 Feb, 2019 | 20:00
Updated-05 Aug, 2024 | 10:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

libcurl versions from 7.36.0 to before 7.64.0 is vulnerable to a heap buffer out-of-bounds read. The function handling incoming NTLM type-2 messages (`lib/vauth/ntlm.c:ntlm_decode_type2_target`) does not validate incoming data correctly and is subject to an integer overflow vulnerability. Using that overflow, a malicious or broken NTLM server could trick libcurl to accept a bad length + offset combination that would lead to a buffer read out-of-bounds.

Action-Not Available
Vendor-NetApp, Inc.Debian GNU/LinuxOracle CorporationRed Hat, Inc.Canonical Ltd.F5, Inc.Siemens AGCURL
Product-libcurlclustered_data_ontapubuntu_linuxdebian_linuxcommunications_operations_monitorhttp_serversecure_global_desktopenterprise_linuxsinema_remote_connect_clientbig-ip_access_policy_managercurl
CWE ID-CWE-125
Out-of-bounds Read
CWE ID-CWE-190
Integer Overflow or Wraparound
CVE-2018-16556
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.19% / 40.88%
||
7 Day CHG~0.00%
Published-13 Dec, 2018 | 16:00
Updated-05 Aug, 2024 | 10:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC S7-400 CPU 412-1 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 DP V7 (All versions), SIMATIC S7-400 CPU 414-2 DP V7 (All versions), SIMATIC S7-400 CPU 414-3 DP V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416-2 DP V7 (All versions), SIMATIC S7-400 CPU 416-3 DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416F-2 DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 417-4 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions < V7.0.3), SIMATIC S7-400 H V4.5 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) (All versions < V6.0.9), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-410 CPU family (incl. SIPLUS variants) (All versions < V8.2.1), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), SIPLUS S7-400 CPU 416-3 V7 (All versions), SIPLUS S7-400 CPU 417-4 V7 (All versions). Specially crafted packets sent to port 102/tcp via Ethernet interface, via PROFIBUS, or via Multi Point Interfaces (MPI) could cause the affected devices to go into defect mode. Manual reboot is required to resume normal operation. Successful exploitation requires an attacker to be able to send specially crafted packets to port 102/tcp via Ethernet interface, via PROFIBUS or Multi Point Interfaces (MPI). No user interaction and no user privileges are required to exploit the security vulnerability. The vulnerability could allow causing a denial of service condition of the core functionality of the CPU, compromising the availability of the system.

Action-Not Available
Vendor-Siemens AG
Product-simatic_s7-400_pn\/dp_v7_firmwaresimatic_s7-400_firmwaresimatic_s7-400h_v6simatic_s7-400simatic_s7-400_pn\/dp_v7simatic_s7-410_firmwaresimatic_s7-400h_firmwaresimatic_s7-410simatic_s7-400h_v6_firmwaresimatic_s7-400h SIMATIC S7-400 CPU 412-2 DP V7 SIMATIC S7-400 CPU 414F-3 PN/DP V7 SIMATIC S7-400 CPU 416-3 DP V7SIPLUS S7-400 CPU 416-3 PN/DP V7 SIMATIC S7-400 CPU 416F-3 PN/DP V7 SIMATIC S7-400 CPU 416F-2 DP V7 SIMATIC S7-400 CPU 414-2 DP V7SIPLUS S7-400 CPU 416-3 V7SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)SIMATIC S7-410 CPU family (incl. SIPLUS variants) SIMATIC S7-400 CPU 417-4 DP V7SIMATIC S7-400 H V4.5 and below CPU family (incl. SIPLUS variants) SIMATIC S7-400 CPU 416-2 DP V7 SIMATIC S7-400 CPU 414-3 PN/DP V7 SIMATIC S7-400 CPU 414-3 DP V7SIPLUS S7-400 CPU 414-3 PN/DP V7SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) SIMATIC S7-400 CPU 416-3 PN/DP V7SIPLUS S7-400 CPU 417-4 V7 SIMATIC S7-400 CPU 412-1 DP V7SIMATIC S7-400 CPU 412-2 PN V7
CWE ID-CWE-20
Improper Input Validation
CVE-2018-16557
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.2||HIGH
EPSS-0.09% / 27.02%
||
7 Day CHG~0.00%
Published-13 Dec, 2018 | 16:00
Updated-05 Aug, 2024 | 10:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC S7-400 CPU 412-1 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 DP V7 (All versions), SIMATIC S7-400 CPU 414-2 DP V7 (All versions), SIMATIC S7-400 CPU 414-3 DP V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416-2 DP V7 (All versions), SIMATIC S7-400 CPU 416-3 DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416F-2 DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 417-4 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions < V7.0.3), SIMATIC S7-400 H V4.5 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) (All versions < V6.0.9), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-410 CPU family (incl. SIPLUS variants) (All versions < V8.2.1), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), SIPLUS S7-400 CPU 416-3 V7 (All versions), SIPLUS S7-400 CPU 417-4 V7 (All versions). Sending of specially crafted packets to port 102/tcp via Ethernet interface via PROFIBUS or Multi Point Interfaces (MPI) could cause a denial of service condition on affected devices. Flashing with a firmware image may be required to recover the CPU. Successful exploitation requires an attacker to have network access to port 102/tcp via Ethernet interface or to be able to send messages via PROFIBUS or Multi Point Interfaces (MPI) to the device. No user interaction is required. If no access protection is configured, no privileges are required to exploit the security vulnerability. The vulnerability could allow causing a denial of service condition of the core functionality of the CPU, compromising the availability of the system.

Action-Not Available
Vendor-Siemens AG
Product-simatic_s7-400_pn\/dp_v7_firmwaresimatic_s7-400_firmwaresimatic_s7-400simatic_s7-400_pn\/dp_v7simatic_s7-410_firmwaresimatic_s7-400h_firmwaresimatic_s7-410simatic_s7-400h SIMATIC S7-400 CPU 412-2 DP V7 SIMATIC S7-400 CPU 414F-3 PN/DP V7 SIMATIC S7-400 CPU 416-3 DP V7SIPLUS S7-400 CPU 416-3 PN/DP V7 SIMATIC S7-400 CPU 416F-3 PN/DP V7 SIMATIC S7-400 CPU 416F-2 DP V7 SIMATIC S7-400 CPU 414-2 DP V7SIPLUS S7-400 CPU 416-3 V7SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)SIMATIC S7-410 CPU family (incl. SIPLUS variants) SIMATIC S7-400 CPU 417-4 DP V7SIMATIC S7-400 H V4.5 and below CPU family (incl. SIPLUS variants) SIMATIC S7-400 CPU 416-2 DP V7 SIMATIC S7-400 CPU 414-3 PN/DP V7 SIMATIC S7-400 CPU 414-3 DP V7SIPLUS S7-400 CPU 414-3 PN/DP V7SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) SIMATIC S7-400 CPU 416-3 PN/DP V7SIPLUS S7-400 CPU 417-4 V7 SIMATIC S7-400 CPU 412-1 DP V7SIMATIC S7-400 CPU 412-2 PN V7
CWE ID-CWE-347
Improper Verification of Cryptographic Signature
CVE-2022-25751
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-3.26% / 86.63%
||
7 Day CHG~0.00%
Published-12 Apr, 2022 | 09:07
Updated-03 Aug, 2024 | 04:49
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices do not properly validate the HTTP headers of incoming requests. This could allow an unauthenticated remote attacker to crash affected devices.

Action-Not Available
Vendor-Siemens AG
Product-scalance_x308-2m_ts_firmwarescalance_x307-3_firmwarescalance_xr324-12mscalance_x310fescalance_x310fe_firmwarescalance_xr324-4m_eecscalance_x308-2ldscalance_x320-1fe_firmwaresiplus_net_scalance_x308-2scalance_xr324-4m_poe_firmwarescalance_x308-2scalance_x307-2eecscalance_xr324-4m_eec_firmwarescalance_x308-2_firmwarescalance_x304-2fe_firmwarescalance_xr324-12m_ts_firmwarescalance_x306-1ldfe_firmwarescalance_x307-2eec_firmwarescalance_x320-1-2ldfesiplus_net_scalance_x308-2_firmwarescalance_x308-2lh_firmwarescalance_x302-7eec_firmwarescalance_x308-2lhscalance_x307-3ld_firmwarescalance_x310scalance_x320-1-2ldfe_firmwarescalance_xr324-12m_firmwarescalance_x308-2m_poe_firmwarescalance_x308-2lh\+scalance_x310_firmwarescalance_x308-2m_poescalance_x308-2lh\+_firmwarescalance_x308-2ld_firmwarescalance_xr324-12m_tsscalance_x308-2m_tsscalance_x308-2m_firmwarescalance_x320-1fescalance_x408-2scalance_xr324-4m_poescalance_x306-1ldfescalance_x307-3ldscalance_x308-2mscalance_x408-2_firmwarescalance_x307-3scalance_x304-2fescalance_xr324-4m_poe_tsscalance_xr324-4m_poe_ts_firmwarescalance_x302-7eecSCALANCE XR324-12M TS (24V)SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)SCALANCE XR324-4M PoE (24V, ports on rear)SCALANCE XR324-4M EEC (24V, ports on front)SCALANCE XR324-12M (230V, ports on rear)SCALANCE X307-2 EEC (2x 24V, coated)SCALANCE XR324-4M PoE TS (24V, ports on front)SCALANCE X307-3SCALANCE X308-2MSCALANCE XR324-12M (24V, ports on rear)SCALANCE X308-2SCALANCE X308-2M PoESCALANCE X310FESCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)SCALANCE X308-2LH+SCALANCE X302-7 EEC (24V, coated)SCALANCE X307-2 EEC (230V, coated)SCALANCE X307-3LDSCALANCE X308-2LHSCALANCE XR324-4M EEC (24V, ports on rear)SCALANCE XR324-4M PoE (24V, ports on front)SCALANCE X302-7 EEC (2x 230V)SCALANCE X408-2SIPLUS NET SCALANCE X308-2SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)SCALANCE XR324-4M PoE (230V, ports on rear)SCALANCE X302-7 EEC (230V)SCALANCE X307-2 EEC (24V, coated)SCALANCE X307-2 EEC (2x 230V, coated)SCALANCE X302-7 EEC (2x 24V, coated)SCALANCE X308-2LDSCALANCE X307-2 EEC (24V)SCALANCE X304-2FESCALANCE X310SCALANCE X307-2 EEC (2x 24V)SCALANCE X307-2 EEC (230V)SCALANCE XR324-12M (24V, ports on front)SCALANCE X320-1 FESCALANCE X302-7 EEC (2x 24V)SCALANCE X306-1LD FESCALANCE X308-2M TSSCALANCE XR324-4M PoE (230V, ports on front)SCALANCE X307-2 EEC (2x 230V)SCALANCE X302-7 EEC (24V)SCALANCE X302-7 EEC (230V, coated)SCALANCE X302-7 EEC (2x 230V, coated)SCALANCE X320-1-2LD FESCALANCE XR324-4M EEC (2x 24V, ports on rear)SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)SCALANCE XR324-12M (230V, ports on front)SCALANCE XR324-4M EEC (2x 24V, ports on front)
CWE ID-CWE-20
Improper Input Validation
CVE-2021-44694
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-5.5||MEDIUM
EPSS-0.07% / 22.26%
||
7 Day CHG~0.00%
Published-13 Dec, 2022 | 00:00
Updated-21 Apr, 2025 | 13:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device.

Action-Not Available
Vendor-Siemens AG
Product-simatic_s7-1500_cpu_1507ssimatic_s7-1200_cpu_12_1214fcsimatic_s7-1500_cpu_cpu_1513pro-2simatic_s7-1500_cpu_1511csimatic_s7-1500_cpu_1511t-1_firmwaresimatic_s7-1500_cpu_1512sp-1siplus_et_200sp_cp_1543sp-1_isec_tx_rail_firmwaresimatic_et_200_sp_open_controller_cpu_1515sp_pc_firmwaresimatic_s7-1200_cpu_12_1214c_firmwaresimatic_s7-1200_cpu_12_1211csimatic_s7-1500_cpu_1508s_f_firmwaresimatic_s7-1500_cpu_1510sp-1simatic_s7-1200_cpu_1212csimatic_s7-1500_cpu_1512spf-1simatic_s7-1500_cpu_1513-1simatic_s7-1200_cpu_1212fc_firmwaresimatic_s7-1500_cpu_1517-3_pnsimatic_s7-1500_cpu_1515-2_pn_firmwaresimatic_s7-1500_cpu_1517f-3_pn\/dpsimatic_s7-1500_cpu_1513r-1simatic_s7-1200_cpu_1215_fcsimatic_s7-1500_cpu_1512c_firmwaresimatic_s7-1500_cpu_1517f-3_pn\/dp_firmwaresimatic_s7-1200_cpu_12_1215csimatic_s7-1500_cpu_1511-1_firmwaresimatic_s7-1500_cpu_1511-1_pnsimatic_s7-1500_cpu_1517f-3_firmwaresimatic_s7-1500_cpu_1518f-4_pn\/dp_firmwaresimatic_s7-1500_cpu_1518hf-4simatic_s7-1500_cpu_1518-4_pn_firmwaresiplus_tim_1531_irc_firmwaresimatic_s7-1500_cpu_1518-4_dp_firmwaresimatic_s7-1500_cpu_1516tf-3_firmwaresimatic_s7-1500_cpu_1511f-1_pn_firmwaresimatic_s7-1500_cpu_1516-3_firmwaresimatic_s7-1500_cpu_1518-4_pn\/dp_mfp_firmwaresimatic_s7-1500_cpu_1517-3_pn\/dpsimatic_s7-1500_cpu_1517-3simatic_s7-1500_cpu_1518t-4_firmwaresimatic_s7-1500_cpu_1508s_fsimatic_s7-1500_cpu_15prof-2_firmwaresimatic_s7-1500_cpu_1513f-1_pnsimatic_s7-1200_cpu_1214c_firmwaresimatic_s7-1500_cpu_1517-3_pn_firmwaresimatic_s7-1500_cpu_1517-3_dpsimatic_s7-1200_cpu_12_1214csimatic_s7-1200_cpu_1211c_firmwaresimatic_s7-1500_cpu_cpu_1513pro-2_firmwaresimatic_s7-1200_cpu_1214csiplus_tim_1531_ircsimatic_s7-1500_cpu_15prof-2simatic_s7-1500_cpu_1516tf-3simatic_s7-1500_cpu_1516f-3_pn\/dp_firmwaresimatic_s7-1500_cpu_151511f-1_firmwaresimatic_s7-1500_cpu_1507s_f_firmwaresimatic_s7-1500_cpu_1516t-3_firmwaresimatic_s7-1500_cpu_1511t-1simatic_s7-1500_cpu_1517tf-3simatic_s7-1500_cpu_1515-2_pnsimatic_s7-1200_cpu_1214_fcsimatic_s7-1500_cpu_1515-2_firmwaresimatic_s7-1500_cpu_1516pro-2_firmwaretim_1531_irc_firmwaresimatic_s7-1500_cpu_1515-2simatic_s7-1500_cpu_1516-3_pnsimatic_s7-1500_cpu_1516pro_f_firmwaresimatic_s7-1500_cpu_1516-3simatic_s7-1200_cpu_1214fcsimatic_s7-1500_cpu_1518f-4_pn\/dpsimatic_s7-1500_cpu_1508s_firmwaresimatic_s7-1500_cpu_1511f-1_firmwaresimatic_s7-1200_cpu_12_1212fcsimatic_s7-1500_cpu_151511c-1simatic_s7-1500_cpu_1518tf-4_firmwaresiplus_s7-1200_cp_1243-1simatic_s7-1500_cpu_1511f-1_pnsimatic_s7-1500_cpu_1507s_fsimatic_s7-1500_cpu_1518simatic_s7-1500_cpu_1513-1_pn_firmwaresimatic_s7-1200_cpu_1215fcsimatic_s7-1500_cpu_1518f-4simatic_s7-1500_cpu_1516pro_fsimatic_s7-1500_cpu_1513r-1_firmwaresimatic_et_200_sp_open_controller_cpu_1515sp_pcsimatic_s7-1500_cpu_1512c-1_firmwaresimatic_s7-1500_cpu_1513f-1_pn_firmwaresiplus_et_200sp_cp_1543sp-1_isec_firmwaresimatic_s7-1500_cpu_1518_firmwaresimatic_s7-1500_cpu_1518-4_firmwaresimatic_s7-1500_cpu_1518tf-4simatic_s7-1200_cpu_1214_fc_firmwaresiplus_s7-1200_cp_1243-1_railsimatic_s7-1500_cpu_1516t-3simatic_s7-1500_cpu_1510sp_firmwaresimatic_s7-1500_cpu_1518-4_pn\/dp_mfpsiplus_et_200sp_cp_1542sp-1_irc_tx_rail_firmwaresimatic_s7-1200_cpu_1215_fc_firmwaresimatic_s7-1200_cpu_12_1215fc_firmwaresimatic_s7-1500_cpu_1515t-2simatic_s7-1500_cpu_15pro-2simatic_s7-1500_cpu_1518-4_pnsimatic_s7-1200_cpu_12_1212c_firmwaresimatic_s7-1200_cpu_12_1212fc_firmwaresimatic_s7-1500_cpu_1511-1_pn_firmwaresimatic_s7-1500_cpu_15pro-2_firmwaresimatic_s7-1500_cpu_1515tf-2_firmwaretim_1531_ircsimatic_s7-1500_cpu_151511c-1_firmwaresimatic_s7-1200_cpu_12_1217csimatic_s7-1500_cpu_1518-4_pn\/dp_firmwaresimatic_s7-1500_cpu_1510spsimatic_s7-1200_cpu_12_1217c_firmwaresimatic_s7-1500_cpu_1518f-4_firmwaresimatic_s7-1200_cpu_1217csimatic_s7-1500_cpu_151511f-1simatic_s7-1500_software_controller_firmwaresimatic_s7-1500_cpu_1511-1simatic_s7-1500_cpu_1518-4_dpsimatic_s7-1200_cpu_1215c_firmwaresimatic_s7-1500_cpu_1513-1_pnsimatic_s7-1200_cpu_1212c_firmwaresimatic_s7-1500_cpu_1515f-2_firmwaresimatic_s7-1200_cpu_1217c_firmwaresimatic_s7-1200_cpu_1214fc_firmwaresimatic_s7-1500_cpu_cpu_1513prof-2_firmwaresimatic_s7-1200_cpu_1215csimatic_s7-1500_cpu_1515r-2simatic_s7-1200_cpu_12_1215fcsiplus_et_200sp_cp_1543sp-1_isecsimatic_s7-1500_cpu_1513f-1simatic_s7-1500_cpu_1512csimatic_s7-1500_cpu_1516f-3_pn\/dpsimatic_s7-1500_cpu_1511c-1simatic_s7-1500_cpu_1517f-3simatic_s7-1500_cpu_1512spf-1_firmwaresiplus_et_200sp_cp_1543sp-1_isec_tx_railsimatic_s7-1500_cpu_1517tf-3_firmwaresimatic_s7-1500_cpu_1516f-3_firmwaresimatic_s7-1500_cpu_1517-3_firmwaresimatic_s7-1200_cpu_12_1214fc_firmwaresimatic_s7-1500_software_controllersimatic_s7-1500_cpu_1511c-1_firmwaresimatic_s7-1500_cpu_1517-3_dp_firmwaresimatic_s7-1500_cpu_1516-3_pn\/dp_firmwaresimatic_s7-1500_cpu_1518hf-4_firmwaresimatic_s7-1200_cpu_12_1212csimatic_s7-1500_cpu_1511f-1simatic_s7-1500_cpu_1515tf-2siplus_s7-1200_cp_1243-1_rail_firmwaresimatic_s7-1500_cpu_1511c_firmwaresimatic_s7-1500_cpu_1511tf-1simatic_s7-1500_cpu_1518-4simatic_s7-1500_cpu_1518-4_pn\/dpsiplus_s7-1200_cp_1243-1_firmwaresimatic_s7-1500_cpu_1511tf-1_firmwaresimatic_s7-1500_cpu_1517-3_pn\/dp_firmwaresimatic_s7-1500_cpu_1516-3_dpsimatic_s7-1500_cpu_1508ssimatic_s7-plcsim_advanced_firmwaresimatic_s7-1500_cpu_1510sp-1_firmwaresimatic_s7-1500_cpu_1516-3_pn\/dpsimatic_s7-1500_cpu_1515f-2_pn_firmwaresimatic_s7-1500_cpu_1515t-2_firmwaresiplus_et_200sp_cp_1542sp-1_irc_tx_railsimatic_s7-1500_cpu_1516-3_dp_firmwaresimatic_s7-1200_cpu_12_1215c_firmwaresimatic_s7-1500_cpu_1512sp-1_firmwaresimatic_s7-1200_cpu_1215fc_firmwaresimatic_s7-1500_cpu_1512c-1simatic_s7-1500_cpu_1515f-2simatic_s7-1500_cpu_cpu_1513prof-2simatic_s7-1500_cpu_1515f-2_pnsimatic_s7-1200_cpu_1211csimatic_s7-1500_cpu_1516f-3simatic_s7-1500_cpu_1516-3_pn_firmwaresimatic_s7-1200_cpu_12_1211c_firmwaresimatic_s7-plcsim_advancedsimatic_s7-1500_cpu_1513f-1_firmwaresimatic_s7-1200_cpu_1212fcsimatic_s7-1500_cpu_1516pro-2simatic_s7-1500_cpu_1515r-2_firmwaresimatic_s7-1500_cpu_1507s_firmwaresimatic_s7-1500_cpu_1513-1_firmwaresimatic_s7-1500_cpu_1518t-4SIMATIC S7-1500 CPU 1512C-1 PNSIMATIC S7-1500 CPU 1517F-3 PN/DPSIMATIC S7-1500 CPU 1515-2 PNSIMATIC S7-1500 CPU 1511T-1 PNSIPLUS S7-1500 CPU 1518-4 PN/DPSIPLUS S7-1500 CPU 1518F-4 PN/DPSIPLUS S7-1500 CPU 1518-4 PN/DP MFPSIMATIC S7-1500 CPU 1515TF-2 PNSIMATIC S7-1500 CPU 1510SP-1 PNSIMATIC S7-1500 CPU 1516-3 PN/DPSIMATIC S7-1500 CPU 1511TF-1 PNSIPLUS S7-1500 CPU 1515F-2 PNSIPLUS S7-1500 CPU 1517H-3 PNSIPLUS ET 200SP CPU 1510SP F-1 PN RAILSIMATIC S7-1500 CPU 1518HF-4 PNSIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PNSIPLUS ET 200SP CPU 1512SP-1 PN RAILSIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PNSIPLUS ET 200SP CPU 1510SP-1 PN RAILSIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PNSIMATIC S7-PLCSIM AdvancedSIMATIC S7-1500 CPU 1517-3 PN/DPSIMATIC S7-1500 CPU 1517H-3 PNSIMATIC S7-1500 CPU 1516TF-3 PN/DPSIMATIC S7-1500 CPU 1515T-2 PNSIMATIC S7-1500 CPU S7-1518-4 PN/DP ODKSIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PNSIPLUS S7-1500 CPU 1516-3 PN/DP RAILSIPLUS S7-1500 CPU 1516-3 PN/DP TX RAILSIMATIC S7-1500 CPU 1511C-1 PNSIMATIC S7-1500 CPU 1517TF-3 PN/DPSIMATIC S7-1200 CPU family (incl. SIPLUS variants)SIPLUS S7-1500 CPU 1515F-2 PN T2 RAILSIPLUS S7-1500 CPU 1511-1 PN TX RAILSIPLUS S7-1500 CPU 1513F-1 PNSIMATIC Drive Controller CPU 1507D TFSIMATIC Drive Controller CPU 1504D TFSIMATIC S7-1500 CPU 1513R-1 PNSIPLUS S7-1500 CPU 1516-3 PN/DPSIMATIC S7-1500 CPU 1515R-2 PNSIMATIC S7-1500 CPU 1512SP F-1 PNTIM 1531 IRCSIPLUS S7-1500 CPU 1511F-1 PNSIPLUS ET 200SP CPU 1512SP F-1 PN RAILSIMATIC S7-1500 Software Controller V2SIMATIC S7-1500 CPU 1518F-4 PN/DP MFPSIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)SIPLUS ET 200SP CPU 1512SP F-1 PNSIMATIC S7-1500 CPU 1515F-2 PNSIMATIC S7-1500 CPU 1518-4 PN/DPSIMATIC S7-1500 CPU 1513-1 PNSIPLUS ET 200SP CPU 1510SP F-1 PNSIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODKSIMATIC S7-1500 CPU 1518F-4 PN/DPSIMATIC S7-1500 CPU 1518-4 PN/DP MFPSIPLUS ET 200SP CPU 1510SP-1 PNSIPLUS S7-1500 CPU 1516F-3 PN/DPSIMATIC S7-1500 CPU 1516T-3 PN/DPSIMATIC S7-1500 CPU 1518TF-4 PN/DPSIPLUS S7-1500 CPU 1515R-2 PN TX RAILSIMATIC S7-1500 CPU 1512SP-1 PNSIMATIC S7-1500 CPU 1518T-4 PN/DPSIMATIC S7-1500 CPU 1511-1 PNSIMATIC S7-1500 CPU 1517T-3 PN/DPSIPLUS S7-1500 CPU 1518HF-4 PNSIPLUS S7-1500 CPU 1513-1 PNSIPLUS S7-1500 CPU 1515R-2 PNSIMATIC S7-1500 CPU 1513F-1 PNSIMATIC S7-1500 CPU 1510SP F-1 PNSIPLUS S7-1500 CPU 1515F-2 PN RAILSIPLUS TIM 1531 IRCSIMATIC S7-1500 CPU 1511F-1 PNSIMATIC S7-1500 CPU 1516F-3 PN/DPSIPLUS ET 200SP CPU 1512SP-1 PNSIPLUS S7-1500 CPU 1511-1 PN T1 RAILSIPLUS S7-1500 CPU 1511-1 PNSIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL
CWE ID-CWE-1287
Improper Validation of Specified Type of Input
CWE ID-CWE-20
Improper Input Validation
CVE-2021-44221
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.54% / 66.59%
||
7 Day CHG~0.00%
Published-12 Jul, 2022 | 10:06
Updated-04 Aug, 2024 | 04:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC eaSie Core Package (All versions < V22.00). The affected systems do not properly validate input that is sent to the underlying message passing framework. This could allow an remote attacker to trigger a denial of service of the affected system.

Action-Not Available
Vendor-Siemens AG
Product-simatic_easie_core_packageSIMATIC eaSie Core Package
CWE ID-CWE-20
Improper Input Validation
CVE-2021-41991
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-2.20% / 83.77%
||
7 Day CHG~0.00%
Published-18 Oct, 2021 | 13:44
Updated-04 Aug, 2024 | 03:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The in-memory certificate cache in strongSwan before 5.9.4 has a remote integer overflow upon receiving many requests with different certificates to fill the cache and later trigger the replacement of cache entries. The code attempts to select a less-often-used cache entry by means of a random number generator, but this is not done correctly. Remote code execution might be a slight possibility.

Action-Not Available
Vendor-strongswann/aDebian GNU/LinuxSiemens AGFedora Project
Product-siplus_s7-1200_cp_1243-1_railsimatic_cp_1242-7_gprs_v2_firmwaresimatic_cp_1542sp-1_firmwarescalance_sc646-2c_firmwaresiplus_et_200sp_cp_1543sp-1_isec_tx_rail_firmwaresiplus_et_200sp_cp_1542sp-1_irc_tx_rail_firmwaresimatic_cp_1243-1_firmwarescalance_sc622-2cscalance_sc646-2csinema_remote_connect_serversiplus_net_cp_1543-1_firmwaresiplus_s7-1200_cp_1243-1_rail_firmwarefedorasimatic_net_cp1243-7_lte_eu_firmwarescalance_sc632-2c_firmwaresimatic_net_cp_1545-1_firmwaresimatic_net_cp_1243-8_ircsimatic_cp_1242-7_gprs_v2scalance_sc622-2c_firmwaresiplus_s7-1200_cp_1243-1_firmwarecp_1543-1_firmwaresimatic_net_cp_1243-8_irc_firmwaresimatic_cp_1243-7_lte\/ussimatic_cp_1543sp-1simatic_cp_1243-7_lte\/us_firmwarestrongswansiplus_et_200sp_cp_1542sp-1_irc_tx_railsiplus_s7-1200_cp_1243-1scalance_sc636-2csimatic_cp_1542sp-1_ircscalance_sc642-2c_firmwaresimatic_cp_1243-1siplus_et_200sp_cp_1543sp-1_isecdebian_linuxsimatic_cp_1542sp-1_irc_firmwarecp_1543-1simatic_net_cp_1545-1simatic_cp_1543sp-1_firmwaresimatic_cp_1542sp-1scalance_sc642-2csiplus_et_200sp_cp_1543sp-1_isec_tx_railsiplus_et_200sp_cp_1543sp-1_isec_firmwaresiplus_net_cp_1543-1simatic_net_cp1243-7_lte_euscalance_sc636-2c_firmwarescalance_sc632-2cn/a
CWE ID-CWE-190
Integer Overflow or Wraparound
CVE-2021-40142
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-0.59% / 68.14%
||
7 Day CHG~0.00%
Published-27 Aug, 2021 | 06:51
Updated-04 Aug, 2024 | 02:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In OPC Foundation Local Discovery Server (LDS) before 1.04.402.463, remote attackers can cause a denial of service (DoS) by sending carefully crafted messages that lead to Access of a Memory Location After the End of a Buffer.

Action-Not Available
Vendor-opcfoundationn/aSiemens AG
Product-telecontrol_server_basicsimatic_wincc_runtimesimatic_winccsimatic_process_historian_opc_ua_server_firmwaresimatic_wincc_unified_scada_runtimesimatic_process_historian_opc_ua_serverlocal_discover_serversimatic_net_pcn/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2021-40365
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.09% / 27.06%
||
7 Day CHG~0.00%
Published-13 Dec, 2022 | 00:00
Updated-21 Apr, 2025 | 13:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device.

Action-Not Available
Vendor-Siemens AG
Product-simatic_s7-1500_cpu_1507ssimatic_s7-1200_cpu_12_1214fcsimatic_s7-1500_cpu_cpu_1513pro-2simatic_s7-1500_cpu_1511csimatic_s7-1500_cpu_1511t-1_firmwaresimatic_s7-1500_cpu_1512sp-1siplus_s7-300_cpu_314siplus_et_200sp_cp_1543sp-1_isec_tx_rail_firmwaresimatic_et_200_sp_open_controller_cpu_1515sp_pc_firmwaresimatic_s7-1200_cpu_12_1214c_firmwaresimatic_s7-1200_cpu_12_1211csimatic_s7-1500_cpu_1508s_f_firmwaresimatic_s7-1500_cpu_1510sp-1simatic_s7-1200_cpu_1212csimatic_s7-1500_cpu_1512spf-1simatic_s7-1500_cpu_1513-1simatic_s7-1200_cpu_1212fc_firmwaresimatic_s7-1500_cpu_1517-3_pnsimatic_s7-1500_cpu_1515-2_pn_firmwaresimatic_s7-1500_cpu_1517f-3_pn\/dpsimatic_s7-1500_cpu_1513r-1simatic_s7-1200_cpu_1215_fcsimatic_s7-1500_cpu_1512c_firmwaresimatic_s7-1500_cpu_1517f-3_pn\/dp_firmwaresimatic_s7-1200_cpu_12_1215csimatic_s7-1500_cpu_1511-1_firmwaresimatic_s7-1500_cpu_1511-1_pnsimatic_s7-1500_cpu_1517f-3_firmwaresimatic_s7-1500_cpu_1518f-4_pn\/dp_firmwaresimatic_s7-1500_cpu_1518hf-4simatic_s7-1500_cpu_1518-4_pn_firmwaresiplus_tim_1531_irc_firmwaresimatic_s7-1500_cpu_1518-4_dp_firmwaresimatic_s7-1500_cpu_1516tf-3_firmwaresimatic_s7-1500_cpu_1511f-1_pn_firmwaresimatic_s7-1500_cpu_1516-3_firmwaresimatic_s7-1500_cpu_1518-4_pn\/dp_mfp_firmwaresimatic_s7-1500_cpu_1517-3_pn\/dpsimatic_s7-1500_cpu_1517-3simatic_s7-1500_cpu_1518t-4_firmwaresimatic_s7-1500_cpu_1508s_fsimatic_s7-1500_cpu_15prof-2_firmwaresimatic_s7-1500_cpu_1513f-1_pnsimatic_s7-1200_cpu_1214c_firmwaresimatic_s7-1500_cpu_1517-3_pn_firmwaresimatic_s7-1500_cpu_1517-3_dpsimatic_s7-1200_cpu_12_1214csimatic_s7-1200_cpu_1211c_firmwaresimatic_s7-1500_cpu_cpu_1513pro-2_firmwaresimatic_s7-1200_cpu_1214csiplus_tim_1531_ircsimatic_s7-1500_cpu_15prof-2simatic_s7-1500_cpu_1516tf-3siplus_s7-300_cpu_315-2_pn\/dp_firmwaresimatic_s7-1500_cpu_1516f-3_pn\/dp_firmwaresimatic_s7-1500_cpu_151511f-1_firmwaresimatic_s7-1500_cpu_1507s_f_firmwaresimatic_s7-1500_cpu_1516t-3_firmwaresimatic_s7-1500_cpu_1511t-1simatic_s7-1500_cpu_1517tf-3simatic_s7-1500_cpu_1515-2_pnsimatic_s7-1200_cpu_1214_fcsimatic_s7-1500_cpu_1515-2_firmwaresimatic_s7-1500_cpu_1516pro-2_firmwaretim_1531_irc_firmwaresimatic_s7-1500_cpu_1515-2simatic_s7-1500_cpu_1516-3_pnsimatic_s7-1500_cpu_1516pro_f_firmwaresimatic_s7-1500_cpu_1516-3simatic_s7-1200_cpu_1214fcsimatic_s7-1500_cpu_1518f-4_pn\/dpsimatic_s7-1500_cpu_1508s_firmwaresimatic_s7-1500_cpu_1511f-1_firmwaresimatic_s7-1200_cpu_12_1212fcsimatic_s7-1500_cpu_151511c-1simatic_s7-1500_cpu_1518tf-4_firmwaresiplus_s7-1200_cp_1243-1simatic_s7-1500_cpu_1511f-1_pnsimatic_s7-1500_cpu_1507s_fsiplus_s7-300_cpu_315-2_dpsimatic_s7-1500_cpu_1518simatic_s7-1500_cpu_1513-1_pn_firmwaresimatic_s7-1200_cpu_1215fcsimatic_s7-1500_cpu_1518f-4simatic_s7-1500_cpu_1516pro_fsimatic_s7-1500_cpu_1513r-1_firmwaresimatic_et_200_sp_open_controller_cpu_1515sp_pcsimatic_s7-1500_cpu_1512c-1_firmwaresimatic_s7-1500_cpu_1513f-1_pn_firmwaresiplus_et_200sp_cp_1543sp-1_isec_firmwaresimatic_s7-1500_cpu_1518_firmwaresimatic_s7-1500_cpu_1518-4_firmwaresimatic_s7-1500_cpu_1518tf-4simatic_s7-1200_cpu_1214_fc_firmwaresiplus_s7-1200_cp_1243-1_railsimatic_s7-1500_cpu_1516t-3simatic_s7-1500_cpu_1510sp_firmwaresimatic_s7-1500_cpu_1518-4_pn\/dp_mfpsiplus_et_200sp_cp_1542sp-1_irc_tx_rail_firmwaresimatic_s7-1200_cpu_1215_fc_firmwaresimatic_s7-1200_cpu_12_1215fc_firmwaresimatic_s7-1500_cpu_1515t-2simatic_s7-1500_cpu_15pro-2simatic_s7-1500_cpu_1518-4_pnsimatic_s7-1200_cpu_12_1212c_firmwaresimatic_s7-1200_cpu_12_1212fc_firmwaresimatic_s7-1500_cpu_1511-1_pn_firmwaresimatic_s7-1500_cpu_15pro-2_firmwaresimatic_s7-1500_cpu_1515tf-2_firmwaretim_1531_ircsimatic_s7-1500_cpu_151511c-1_firmwaresimatic_s7-1200_cpu_12_1217csimatic_s7-1500_cpu_1518-4_pn\/dp_firmwaresimatic_s7-1500_cpu_1510spsimatic_s7-1200_cpu_12_1217c_firmwaresimatic_s7-1500_cpu_1518f-4_firmwaresimatic_s7-1200_cpu_1217csimatic_s7-1500_cpu_151511f-1simatic_s7-1500_software_controller_firmwaresimatic_s7-1500_cpu_1511-1simatic_s7-1500_cpu_1518-4_dpsiplus_s7-300_cpu_317-2_pn\/dp_firmwaresimatic_s7-1200_cpu_1215c_firmwaresimatic_s7-1500_cpu_1513-1_pnsimatic_s7-1200_cpu_1212c_firmwaresimatic_s7-1500_cpu_1515f-2_firmwaresimatic_s7-1200_cpu_1217c_firmwaresimatic_s7-1200_cpu_1214fc_firmwaresimatic_s7-1500_cpu_cpu_1513prof-2_firmwaresimatic_s7-1200_cpu_1215csimatic_s7-1500_cpu_1515r-2simatic_s7-1200_cpu_12_1215fcsiplus_et_200sp_cp_1543sp-1_isecsimatic_s7-1500_cpu_1513f-1simatic_s7-1500_cpu_1512csimatic_s7-1500_cpu_1516f-3_pn\/dpsimatic_s7-1500_cpu_1511c-1simatic_s7-1500_cpu_1517f-3simatic_s7-1500_cpu_1512spf-1_firmwaresiplus_s7-300_cpu_314_firmwaresiplus_et_200sp_cp_1543sp-1_isec_tx_railsimatic_s7-1500_cpu_1517tf-3_firmwaresimatic_s7-1500_cpu_1516f-3_firmwaresimatic_s7-1500_cpu_1517-3_firmwaresimatic_s7-1200_cpu_12_1214fc_firmwaresimatic_s7-1500_software_controllersimatic_s7-1500_cpu_1511c-1_firmwaresimatic_s7-1500_cpu_1517-3_dp_firmwaresimatic_s7-1500_cpu_1516-3_pn\/dp_firmwaresimatic_s7-1500_cpu_1518hf-4_firmwaresimatic_s7-1200_cpu_12_1212csiplus_s7-300_cpu_315-2_pn\/dpsimatic_s7-1500_cpu_1511f-1siplus_s7-300_cpu_317-2_pn\/dpsimatic_s7-1500_cpu_1515tf-2siplus_s7-1200_cp_1243-1_rail_firmwaresimatic_s7-1500_cpu_1511c_firmwaresimatic_s7-1500_cpu_1511tf-1simatic_s7-1500_cpu_1518-4simatic_s7-1500_cpu_1518-4_pn\/dpsiplus_s7-1200_cp_1243-1_firmwaresimatic_s7-1500_cpu_1511tf-1_firmwaresimatic_s7-1500_cpu_1517-3_pn\/dp_firmwaresimatic_s7-1500_cpu_1516-3_dpsimatic_s7-1500_cpu_1508ssiplus_s7-300_cpu_315-2_dp_firmwaresimatic_s7-plcsim_advanced_firmwaresimatic_s7-1500_cpu_1510sp-1_firmwaresimatic_s7-1500_cpu_1516-3_pn\/dpsimatic_s7-1500_cpu_1515f-2_pn_firmwaresimatic_s7-1500_cpu_1515t-2_firmwaresiplus_et_200sp_cp_1542sp-1_irc_tx_railsimatic_s7-1500_cpu_1516-3_dp_firmwaresimatic_s7-1200_cpu_12_1215c_firmwaresimatic_s7-1500_cpu_1512sp-1_firmwaresimatic_s7-1200_cpu_1215fc_firmwaresimatic_s7-1500_cpu_1512c-1simatic_s7-1500_cpu_1515f-2simatic_s7-1500_cpu_cpu_1513prof-2simatic_s7-1500_cpu_1515f-2_pnsimatic_s7-1200_cpu_1211csimatic_s7-1500_cpu_1516f-3simatic_s7-1500_cpu_1516-3_pn_firmwaresimatic_s7-1200_cpu_12_1211c_firmwaresimatic_s7-plcsim_advancedsimatic_s7-1500_cpu_1513f-1_firmwaresimatic_s7-1200_cpu_1212fcsimatic_s7-1500_cpu_1516pro-2simatic_s7-1500_cpu_1515r-2_firmwaresimatic_s7-1500_cpu_1507s_firmwaresimatic_s7-1500_cpu_1513-1_firmwaresimatic_s7-1500_cpu_1518t-4SIMATIC S7-1500 CPU 1512C-1 PNSIMATIC S7-1500 CPU 1517F-3 PN/DPSIMATIC S7-1500 CPU 1515-2 PNSIMATIC S7-1500 CPU 1511T-1 PNSIPLUS S7-1500 CPU 1518-4 PN/DPSIPLUS S7-1500 CPU 1518F-4 PN/DPSIPLUS S7-1500 CPU 1518-4 PN/DP MFPSIMATIC S7-1500 CPU 1515TF-2 PNSIMATIC S7-1500 CPU 1510SP-1 PNSIMATIC S7-1500 CPU 1516-3 PN/DPSIMATIC S7-1500 CPU 1511TF-1 PNSIPLUS S7-1500 CPU 1515F-2 PNSIPLUS S7-1500 CPU 1517H-3 PNSIPLUS ET 200SP CPU 1510SP F-1 PN RAILSIMATIC S7-1500 CPU 1518HF-4 PNSIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PNSIPLUS ET 200SP CPU 1512SP-1 PN RAILSIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PNSIPLUS ET 200SP CPU 1510SP-1 PN RAILSIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PNSIMATIC S7-PLCSIM AdvancedSIMATIC S7-1500 CPU 1517-3 PN/DPSIMATIC S7-1500 CPU 1517H-3 PNSIMATIC S7-1500 CPU 1516TF-3 PN/DPSIMATIC S7-1500 CPU 1515T-2 PNSIMATIC S7-1500 CPU S7-1518-4 PN/DP ODKSIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PNSIPLUS S7-1500 CPU 1516-3 PN/DP RAILSIPLUS S7-1500 CPU 1516-3 PN/DP TX RAILSIMATIC S7-1500 CPU 1511C-1 PNSIMATIC S7-1500 CPU 1517TF-3 PN/DPSIMATIC S7-1200 CPU family (incl. SIPLUS variants)SIPLUS S7-1500 CPU 1515F-2 PN T2 RAILSIPLUS S7-1500 CPU 1511-1 PN TX RAILSIPLUS S7-1500 CPU 1513F-1 PNSIMATIC Drive Controller CPU 1507D TFSIMATIC Drive Controller CPU 1504D TFSIMATIC S7-1500 CPU 1513R-1 PNSIPLUS S7-1500 CPU 1516-3 PN/DPSIMATIC S7-1500 CPU 1515R-2 PNSIMATIC S7-1500 CPU 1512SP F-1 PNTIM 1531 IRCSIPLUS S7-1500 CPU 1511F-1 PNSIPLUS ET 200SP CPU 1512SP F-1 PN RAILSIMATIC S7-1500 Software Controller V2SIMATIC S7-1500 CPU 1518F-4 PN/DP MFPSIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)SIPLUS ET 200SP CPU 1512SP F-1 PNSIMATIC S7-1500 CPU 1515F-2 PNSIMATIC S7-1500 CPU 1518-4 PN/DPSIMATIC S7-1500 CPU 1513-1 PNSIPLUS ET 200SP CPU 1510SP F-1 PNSIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODKSIMATIC S7-1500 CPU 1518F-4 PN/DPSIMATIC S7-1500 CPU 1518-4 PN/DP MFPSIPLUS ET 200SP CPU 1510SP-1 PNSIPLUS S7-1500 CPU 1516F-3 PN/DPSIMATIC S7-1500 CPU 1516T-3 PN/DPSIMATIC S7-1500 CPU 1518TF-4 PN/DPSIPLUS S7-1500 CPU 1515R-2 PN TX RAILSIMATIC S7-1500 CPU 1512SP-1 PNSIMATIC S7-1500 CPU 1518T-4 PN/DPSIMATIC S7-1500 CPU 1511-1 PNSIMATIC S7-1500 CPU 1517T-3 PN/DPSIPLUS S7-1500 CPU 1518HF-4 PNSIPLUS S7-1500 CPU 1513-1 PNSIPLUS S7-1500 CPU 1515R-2 PNSIMATIC S7-1500 CPU 1513F-1 PNSIMATIC S7-1500 CPU 1510SP F-1 PNSIPLUS S7-1500 CPU 1515F-2 PN RAILSIPLUS TIM 1531 IRCSIMATIC S7-1500 CPU 1511F-1 PNSIMATIC S7-1500 CPU 1516F-3 PN/DPSIPLUS ET 200SP CPU 1512SP-1 PNSIPLUS S7-1500 CPU 1511-1 PN T1 RAILSIPLUS S7-1500 CPU 1511-1 PNSIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL
CWE ID-CWE-20
Improper Input Validation
CVE-2021-37185
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-1.43% / 79.86%
||
7 Day CHG~0.00%
Published-09 Feb, 2022 | 15:16
Updated-18 Apr, 2025 | 18:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations.

Action-Not Available
Vendor-Siemens AG
Product-simatic_et_200sp_open_controller_cpu_1515sp_pc2_firmwaresimatic_s7-1500_cpu_1516t-3simatic_s7-1500_cpu_1510sp_firmwaresimatic_s7-1500_cpu_cpu_1513pro-2simatic_s7-1500_cpu_1511t-1_firmwaresimatic_s7-1500_cpu_1512sp-1simatic_s7-1500_cpu_1510sp-1simatic_s7-1200_cpu_1212csimatic_s7-1500_cpu_1515t-2simatic_s7-1500_cpu_1512spf-1simatic_drive_controller_cpu_1507d_tf_firmwaresimatic_s7-1500_cpu_1513-1simatic_s7-1500_cpu_1515tf-2_firmwaretim_1531_ircsimatic_s7-1200_cpu_1212fc_firmwaresimatic_s7-1500_cpu_1510spsimatic_s7-1500_cpu_1518f-4_firmwaresimatic_s7-1200_cpu_1217csimatic_s7-1500_cpu_1513r-1simatic_s7-1500_cpu_1511-1simatic_s7-1200_cpu_1215c_firmwaresimatic_s7-1500_cpu_1517f-3_firmwaresimatic_s7-1500_cpu_1511-1_firmwaresimatic_s7-1500_cpu_1518tf-4simatic_s7-1200_cpu_1212c_firmwaresimatic_s7-1500_cpu_1515f-2_firmwaresimatic_s7-1200_cpu_1217c_firmwaresimatic_s7-1500_cpu_1518hf-4simatic_s7-1200_cpu_1214fc_firmwaresimatic_s7-1500_cpu_cpu_1513prof-2_firmwaresimatic_s7-1200_cpu_1215csimatic_s7-1500_cpu_1515r-2simatic_s7-1500_cpu_1516tf-3_firmwaresimatic_s7-1500_cpu_1516-3_firmwaresimatic_s7-1500_cpu_1513f-1simatic_s7-1500_cpu_1511c-1simatic_s7-1500_cpu_1517-3simatic_s7-1500_cpu_1518t-4_firmwaresimatic_s7-1500_cpu_1517f-3simatic_s7-1500_cpu_1512spf-1_firmwaresimatic_s7-1200_cpu_1214c_firmwaresimatic_s7-1500_cpu_1517tf-3_firmwaresimatic_s7-1500_cpu_1516f-3_firmwaresimatic_s7-1500_cpu_cpu_1513pro-2_firmwaresimatic_s7-1200_cpu_1211c_firmwaresimatic_s7-1500_cpu_1517-3_firmwaresimatic_s7-1200_cpu_1214csimatic_s7-1500_software_controllersimatic_s7-1500_cpu_1516tf-3simatic_s7-1500_cpu_1511c-1_firmwaresimatic_s7-1500_cpu_1516t-3_firmwaresimatic_s7-1500_cpu_1518hf-4_firmwaresimatic_s7-1500_cpu_1511t-1simatic_drive_controller_cpu_1504d_tf_firmwaresimatic_s7-1500_cpu_1517tf-3simatic_s7-1500_cpu_1511f-1simatic_s7-1500_cpu_1515tf-2tim_1531_irc_firmwaresimatic_s7-1500_cpu_1515-2_firmwaresimatic_s7-1500_cpu_1516pro-2_firmwaresimatic_s7-1500_cpu_1511tf-1simatic_s7-1500_cpu_1515-2simatic_s7-1500_cpu_1518-4simatic_s7-1500_cpu_1511tf-1_firmwaresimatic_s7-1500_cpu_1516pro_f_firmwaresimatic_s7-plcsim_advanced_firmwaresimatic_s7-1500_cpu_1510sp-1_firmwaresimatic_s7-1500_cpu_1516-3simatic_s7-1200_cpu_1214fcsimatic_s7-1500_cpu_1515t-2_firmwaresimatic_drive_controller_cpu_1504d_tfsimatic_drive_controller_cpu_1507d_tfsimatic_s7-1500_cpu_1511f-1_firmwaresimatic_s7-1500_cpu_1518tf-4_firmwaresimatic_s7-1500_cpu_1512sp-1_firmwaresimatic_s7-1200_cpu_1215fc_firmwaresimatic_s7-1500_cpu_1512c-1simatic_s7-1500_cpu_cpu_1513prof-2simatic_s7-1500_cpu_1515f-2simatic_s7-1200_cpu_1211csimatic_s7-1500_cpu_1516f-3simatic_s7-1200_cpu_1215fcsimatic_s7-1500_cpu_1518f-4simatic_s7-1500_cpu_1516pro_fsimatic_s7-1500_cpu_1513r-1_firmwaresimatic_s7-1500_cpu_1512c-1_firmwaresimatic_s7-1500_cpu_1513f-1_firmwaresimatic_s7-1200_cpu_1212fcsimatic_s7-1500_cpu_1516pro-2simatic_s7-1500_cpu_1515r-2_firmwaresimatic_s7-plcsim_advancedsimatic_s7-1500_cpu_1513-1_firmwaresimatic_s7-1500_cpu_1518-4_firmwaresimatic_s7-1500_cpu_1518t-4simatic_et_200sp_open_controller_cpu_1515sp_pc2TIM 1531 IRCSIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)SIMATIC S7-PLCSIM AdvancedSIMATIC Drive Controller familySIMATIC S7-1200 CPU family (incl. SIPLUS variants)SIMATIC S7-1500 Software ControllerSIPLUS TIM 1531 IRCSIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)
CWE ID-CWE-672
Operation on a Resource after Expiration or Release
CVE-2021-37204
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-1.43% / 79.86%
||
7 Day CHG~0.00%
Published-09 Feb, 2022 | 15:16
Updated-18 Apr, 2025 | 18:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 Ready4Linux (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packet over port 102/tcp. A restart of the affected device is needed to restore normal operations.

Action-Not Available
Vendor-Siemens AG
Product-simatic_et_200sp_open_controller_cpu_1515sp_pc2_firmwaresimatic_s7-1500_cpu_1516t-3simatic_s7-1500_cpu_1510sp_firmwaresimatic_s7-1500_cpu_cpu_1513pro-2simatic_s7-1500_cpu_1511t-1_firmwaresimatic_s7-1500_cpu_1512sp-1simatic_s7-1500_cpu_1510sp-1simatic_s7-1200_cpu_1212csimatic_s7-1500_cpu_1515t-2simatic_s7-1500_cpu_1512spf-1simatic_drive_controller_cpu_1507d_tf_firmwaresimatic_s7-1500_cpu_1513-1simatic_s7-1500_cpu_1515tf-2_firmwaretim_1531_ircsimatic_s7-1200_cpu_1212fc_firmwaresimatic_s7-1500_cpu_1510spsimatic_s7-1500_cpu_1518f-4_firmwaresimatic_s7-1200_cpu_1217csimatic_s7-1500_cpu_1513r-1simatic_s7-1500_cpu_1511-1simatic_s7-1200_cpu_1215c_firmwaresimatic_s7-1500_cpu_1517f-3_firmwaresimatic_s7-1500_cpu_1511-1_firmwaresimatic_s7-1500_cpu_1518tf-4simatic_s7-1200_cpu_1212c_firmwaresimatic_s7-1500_cpu_1515f-2_firmwaresimatic_s7-1200_cpu_1217c_firmwaresimatic_s7-1500_cpu_1518hf-4simatic_s7-1200_cpu_1214fc_firmwaresimatic_s7-1500_cpu_cpu_1513prof-2_firmwaresimatic_s7-1200_cpu_1215csimatic_s7-1500_cpu_1515r-2simatic_s7-1500_cpu_1516tf-3_firmwaresimatic_s7-1500_cpu_1516-3_firmwaresimatic_s7-1500_cpu_1513f-1simatic_s7-1500_cpu_1511c-1simatic_s7-1500_cpu_1517-3simatic_s7-1500_cpu_1518t-4_firmwaresimatic_s7-1500_cpu_1517f-3simatic_s7-1500_cpu_1512spf-1_firmwaresimatic_s7-1200_cpu_1214c_firmwaresimatic_s7-1500_cpu_1517tf-3_firmwaresimatic_s7-1500_cpu_1516f-3_firmwaresimatic_s7-1500_cpu_cpu_1513pro-2_firmwaresimatic_s7-1200_cpu_1211c_firmwaresimatic_s7-1500_cpu_1517-3_firmwaresimatic_s7-1200_cpu_1214csimatic_s7-1500_software_controllersimatic_s7-1500_cpu_1516tf-3simatic_s7-1500_cpu_1511c-1_firmwaresimatic_s7-1500_cpu_1516t-3_firmwaresimatic_s7-1500_cpu_1518hf-4_firmwaresimatic_s7-1500_cpu_1511t-1simatic_drive_controller_cpu_1504d_tf_firmwaresimatic_s7-1500_cpu_1517tf-3simatic_s7-1500_cpu_1511f-1simatic_s7-1500_cpu_1515tf-2tim_1531_irc_firmwaresimatic_s7-1500_cpu_1515-2_firmwaresimatic_s7-1500_cpu_1516pro-2_firmwaresimatic_s7-1500_cpu_1511tf-1simatic_s7-1500_cpu_1515-2simatic_s7-1500_cpu_1518-4simatic_s7-1500_cpu_1511tf-1_firmwaresimatic_s7-1500_cpu_1516pro_f_firmwaresimatic_s7-plcsim_advanced_firmwaresimatic_s7-1500_cpu_1510sp-1_firmwaresimatic_s7-1500_cpu_1516-3simatic_s7-1200_cpu_1214fcsimatic_s7-1500_cpu_1515t-2_firmwaresimatic_drive_controller_cpu_1504d_tfsimatic_drive_controller_cpu_1507d_tfsimatic_s7-1500_cpu_1511f-1_firmwaresimatic_s7-1500_cpu_1518tf-4_firmwaresimatic_s7-1500_cpu_1512sp-1_firmwaresimatic_s7-1200_cpu_1215fc_firmwaresimatic_s7-1500_cpu_1512c-1simatic_s7-1500_cpu_cpu_1513prof-2simatic_s7-1500_cpu_1515f-2simatic_s7-1200_cpu_1211csimatic_s7-1500_cpu_1516f-3simatic_s7-1200_cpu_1215fcsimatic_s7-1500_cpu_1518f-4simatic_s7-1500_cpu_1516pro_fsimatic_s7-1500_cpu_1513r-1_firmwaresimatic_s7-1500_cpu_1512c-1_firmwaresimatic_s7-1500_cpu_1513f-1_firmwaresimatic_s7-1200_cpu_1212fcsimatic_s7-1500_cpu_1516pro-2simatic_s7-1500_cpu_1515r-2_firmwaresimatic_s7-plcsim_advancedsimatic_s7-1500_cpu_1513-1_firmwaresimatic_s7-1500_cpu_1518-4_firmwaresimatic_s7-1500_cpu_1518t-4simatic_et_200sp_open_controller_cpu_1515sp_pc2SIMATIC ET 200SP Open Controller CPU 1515SP PC2 Ready4LinuxTIM 1531 IRCSIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)SIMATIC S7-PLCSIM AdvancedSIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)SIMATIC Drive Controller familySIMATIC S7-1200 CPU family (incl. SIPLUS variants)SIMATIC S7-1500 Software ControllerSIPLUS TIM 1531 IRCSIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)
CWE ID-CWE-672
Operation on a Resource after Expiration or Release
CVE-2021-3749
Matching Score-8
Assigner-Protect AI (formerly huntr.dev)
ShareView Details
Matching Score-8
Assigner-Protect AI (formerly huntr.dev)
CVSS Score-7.5||HIGH
EPSS-8.37% / 91.93%
||
7 Day CHG-0.21%
Published-31 Aug, 2021 | 10:36
Updated-03 Aug, 2024 | 17:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Inefficient Regular Expression Complexity in axios/axios

axios is vulnerable to Inefficient Regular Expression Complexity

Action-Not Available
Vendor-axiosaxiosOracle CorporationSiemens AG
Product-sinec_insgoldengateaxiosaxios/axios
CWE ID-CWE-1333
Inefficient Regular Expression Complexity
CWE ID-CWE-400
Uncontrolled Resource Consumption
CVE-2021-31882
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-6.5||MEDIUM
EPSS-1.41% / 79.76%
||
7 Day CHG~0.00%
Published-09 Nov, 2021 | 11:31
Updated-11 Mar, 2025 | 09:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303). The DHCP client application does not validate the length of the Domain Name Server IP option(s) (0x06) when processing DHCP ACK packets. This may lead to Denial-of-Service conditions. (FSMD-2021-0011)

Action-Not Available
Vendor-Siemens AG
Product-nucleus_readystart_v3talon_tc_compactnucleus_nettalon_tc_compact_firmwareapogee_pxc_compactapogee_modular_equiment_controller_firmwareapogee_pxc_compact_firmwareapogee_modular_equiment_controllerapogee_modular_building_controllercapital_vstarapogee_pxc_modular_firmwareapogee_pxc_modulartalon_tc_modular_firmwaretalon_tc_modularapogee_modular_building_controller_firmwarenucleus_source_codeCapital Embedded AR Classic 431-422Capital Embedded AR Classic R20-11
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2021-25662
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.74% / 71.98%
||
7 Day CHG~0.00%
Published-12 May, 2021 | 13:18
Updated-03 Aug, 2024 | 20:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC client fails to handle an exception properly if the program execution process is modified after sending a packet from the server, which could result in a Denial-of-Service condition.

Action-Not Available
Vendor-Siemens AG
Product-simatic_hmi_comfort_panels_22\"simatic_hmi_ktp_mobile_panels_ktp700fsimatic_hmi_ktp_mobile_panels_ktp900_firmwaresimatic_hmi_ktp_mobile_panels_ktp900fsimatic_hmi_ktp_mobile_panels_ktp400fsimatic_hmi_comfort_outdoor_panels_7\"simatic_hmi_ktp_mobile_panels_ktp700simatic_hmi_ktp_mobile_panels_ktp700f_firmwaresimatic_hmi_comfort_outdoor_panels_15\"_firmwaresimatic_hmi_ktp_mobile_panels_ktp900f_firmwaresimatic_hmi_ktp_mobile_panels_ktp400f_firmwaresimatic_hmi_comfort_panels_4\"simatic_hmi_comfort_panels_4\"_firmwaresimatic_hmi_ktp_mobile_panels_ktp900simatic_hmi_comfort_outdoor_panels_15\"simatic_hmi_comfort_outdoor_panels_7\"_firmwaresimatic_hmi_comfort_panels_22\"_firmwaresimatic_wincc_runtime_advancedsimatic_hmi_ktp_mobile_panels_ktp700_firmwareSIMATIC WinCC Runtime Advanced V16SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants)SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants)SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900FSIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F SIMATIC WinCC Runtime Advanced V15
CWE ID-CWE-755
Improper Handling of Exceptional Conditions
CVE-2021-25143
Matching Score-8
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-8
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-7.5||HIGH
EPSS-0.67% / 70.32%
||
7 Day CHG~0.00%
Published-29 Mar, 2021 | 19:03
Updated-03 Aug, 2024 | 19:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A remote denial of service (dos) vulnerability was discovered in some Aruba Instant Access Point (IAP) products in version(s): Aruba Instant 8.3.x: 8.3.0.12 and below; Aruba Instant 8.5.x: 8.5.0.9 and below; Aruba Instant 8.6.x: 8.6.0.4 and below. Aruba has released patches for Aruba Instant that address this security vulnerability.

Action-Not Available
Vendor-n/aSiemens AGAruba Networks
Product-scalance_w1750d_firmwareinstantscalance_w1750dAruba Instant Access Points
CVE-2021-25215
Matching Score-8
Assigner-Internet Systems Consortium (ISC)
ShareView Details
Matching Score-8
Assigner-Internet Systems Consortium (ISC)
CVSS Score-7.5||HIGH
EPSS-1.68% / 81.43%
||
7 Day CHG~0.00%
Published-29 Apr, 2021 | 00:55
Updated-16 Sep, 2024 | 22:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
An assertion check can fail while answering queries for DNAME records that require the DNAME to be processed to resolve itself

In BIND 9.0.0 -> 9.11.29, 9.12.0 -> 9.16.13, and versions BIND 9.9.3-S1 -> 9.11.29-S1 and 9.16.8-S1 -> 9.16.13-S1 of BIND Supported Preview Edition, as well as release versions 9.17.0 -> 9.17.11 of the BIND 9.17 development branch, when a vulnerable version of named receives a query for a record triggering the flaw described above, the named process will terminate due to a failed assertion check. The vulnerability affects all currently maintained BIND 9 branches (9.11, 9.11-S, 9.16, 9.16-S, 9.17) as well as all other versions of BIND 9.

Action-Not Available
Vendor-Internet Systems Consortium, Inc.Debian GNU/LinuxNetApp, Inc.Oracle CorporationSiemens AGFedora Project
Product-h300e500f_firmwarea250_firmwareh500scloud_backuptekelec_platform_distributionh300s_firmwareactive_iq_unified_managerh410sh300sh300e_firmwaresinec_infrastructure_network_services500fdebian_linuxh500eh410s_firmwarefedorah500s_firmwareh500e_firmwareh700s_firmwarea250h700ebindh700e_firmwareh700sBIND9
CWE ID-CWE-617
Reachable Assertion
CVE-2021-22883
Matching Score-8
Assigner-HackerOne
ShareView Details
Matching Score-8
Assigner-HackerOne
CVSS Score-7.5||HIGH
EPSS-87.36% / 99.42%
||
7 Day CHG~0.00%
Published-03 Mar, 2021 | 17:38
Updated-30 Apr, 2025 | 22:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Node.js before 10.24.0, 12.21.0, 14.16.0, and 15.10.0 is vulnerable to a denial of service attack when too many connection attempts with an 'unknownProtocol' are established. This leads to a leak of file descriptors. If a file descriptor limit is configured on the system, then the server is unable to accept new connections and prevent the process also from opening, e.g. a file. If no file descriptor limit is configured, then this lead to an excessive memory usage and cause the system to run out of memory.

Action-Not Available
Vendor-Node.js (OpenJS Foundation)Oracle CorporationNetApp, Inc.Siemens AGFedora Project
Product-sinec_infrastructure_network_servicespeoplesoft_enterprise_peopletoolsgraalvme-series_performance_analyzermysql_clusternosql_databasefedorajd_edwards_enterpriseone_toolsnode.jsNode
CWE ID-CWE-400
Uncontrolled Resource Consumption
CWE ID-CWE-772
Missing Release of Resource after Effective Lifetime
CVE-2021-22926
Matching Score-8
Assigner-HackerOne
ShareView Details
Matching Score-8
Assigner-HackerOne
CVSS Score-7.5||HIGH
EPSS-0.77% / 72.49%
||
7 Day CHG~0.00%
Published-05 Aug, 2021 | 00:00
Updated-03 Aug, 2024 | 18:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

libcurl-using applications can ask for a specific client certificate to be used in a transfer. This is done with the `CURLOPT_SSLCERT` option (`--cert` with the command line tool).When libcurl is built to use the macOS native TLS library Secure Transport, an application can ask for the client certificate by name or with a file name - using the same option. If the name exists as a file, it will be used instead of by name.If the appliction runs with a current working directory that is writable by other users (like `/tmp`), a malicious user can create a file name with the same name as the app wants to use by name, and thereby trick the application to use the file based cert instead of the one referred to by name making libcurl send the wrong client certificate in the TLS connection handshake.

Action-Not Available
Vendor-n/aNetApp, Inc.Oracle CorporationSplunk LLC (Cisco Systems, Inc.)CURLSiemens AG
Product-h300epeoplesoft_enterprise_peopletoolsh500sh300s_firmwareactive_iq_unified_managerh410soncommand_workflow_automationcurlh300suniversal_forwardersolidfiresnapcentersinec_infrastructure_network_servicesh300e_firmwareclustered_data_ontaph500ehci_management_nodeh410s_firmwareh700s_firmwareh500s_firmwareh500e_firmwareh700eh700e_firmwaremysql_serverh700soncommand_insighthttps://github.com/curl/curl
CWE ID-CWE-840
Not Available
CWE ID-CWE-295
Improper Certificate Validation
CVE-2022-38371
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.51% / 65.58%
||
7 Day CHG~0.00%
Published-11 Oct, 2022 | 00:00
Updated-13 May, 2025 | 09:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.7), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.21), APOGEE PXC Modular (BACnet) (All versions < V3.5.7), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.21), Desigo PXC00-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC00-U (All versions >= V2.3 < V6.30.37), Desigo PXC001-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC100-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC12-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC128-U (All versions >= V2.3 < V6.30.37), Desigo PXC200-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC22-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC22.1-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC36.1-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC50-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC64-U (All versions >= V2.3 < V6.30.37), Desigo PXM20-E (All versions >= V2.3 < V6.30.37), Nucleus NET for Nucleus PLUS V1 (All versions < V5.2a), Nucleus NET for Nucleus PLUS V2 (All versions < V5.4), Nucleus ReadyStart V3 V2012 (All versions < V2012.08.1), Nucleus ReadyStart V3 V2017 (All versions < V2017.02.4), Nucleus Source Code (All versions including affected FTP server), TALON TC Compact (BACnet) (All versions < V3.5.7), TALON TC Modular (BACnet) (All versions < V3.5.7). The FTP server does not properly release memory resources that were reserved for incomplete connection attempts by FTP clients. This could allow a remote attacker to generate a denial of service condition on devices that incorporate a vulnerable version of the FTP server.

Action-Not Available
Vendor-Siemens AG
Product-talon_tc_compactdesigo_pxm20-edesigo_pxc22.1-e.dapogee_pxc_compactdesigo_pxc001-e.d_firmwaredesigo_pxc12-e.dapogee_modular_equiment_controller_firmwareapogee_pxc_compact_firmwaredesigo_pxc200-e.d_firmwareapogee_modular_equiment_controllerdesigo_pxc100-e.dapogee_modular_building_controllerdesigo_pxc001-e.dapogee_pxc_modular_firmwaredesigo_pxc22.1-e.d_firmwaredesigo_pxc50-e.dapogee_modular_building_controller_firmwaredesigo_pxc12-e.d_firmwaredesigo_pxc22-e.ddesigo_pxc22-e.d_firmwaredesigo_pxc00-u_firmwarenucleus_readystart_v3desigo_pxc00-e.ddesigo_pxc100-e.d_firmwaredesigo_pxc200-e.ddesigo_pxc00-e.d_firmwaredesigo_pxc50-e.d_firmwarenucleus_netdesigo_pxc64-utalon_tc_compact_firmwaredesigo_pxc36.1-e.d_firmwaredesigo_pxc64-u_firmwaredesigo_pxc128-udesigo_pxc00-uapogee_pxc_modulardesigo_pxm20-e_firmwaredesigo_pxc36.1-e.ddesigo_pxc128-u_firmwarenucleus_source_codeDesigo PXC22.1-E.DAPOGEE PXC Modular (P2 Ethernet)Nucleus ReadyStart V3 V2017Desigo PXC50-E.DDesigo PXC64-UDesigo PXC001-E.DAPOGEE PXC Compact (P2 Ethernet)Desigo PXC36.1-E.DNucleus NET for Nucleus PLUS V1TALON TC Compact (BACnet)APOGEE PXC Modular (BACnet)APOGEE MBC (PPC) (P2 Ethernet)Desigo PXC22-E.DTALON TC Modular (BACnet)Desigo PXC100-E.DAPOGEE PXC Compact (BACnet)APOGEE MEC (PPC) (BACnet)Desigo PXC00-UDesigo PXC00-E.DDesigo PXC200-E.DDesigo PXM20-EAPOGEE MEC (PPC) (P2 Ethernet)APOGEE MBC (PPC) (BACnet)Nucleus Source CodeDesigo PXC12-E.DNucleus NET for Nucleus PLUS V2Desigo PXC128-UNucleus ReadyStart V3 V2012
CWE ID-CWE-400
Uncontrolled Resource Consumption
CWE ID-CWE-401
Missing Release of Memory after Effective Lifetime
CVE-2024-52504
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.11% / 29.48%
||
7 Day CHG~0.00%
Published-12 Aug, 2025 | 11:16
Updated-12 Aug, 2025 | 19:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIPROTEC 4 6MD61 (All versions), SIPROTEC 4 6MD63 (All versions), SIPROTEC 4 6MD66 (All versions), SIPROTEC 4 6MD665 (All versions), SIPROTEC 4 7SA522 (All versions), SIPROTEC 4 7SA6 (All versions < V4.78), SIPROTEC 4 7SD5 (All versions < V4.78), SIPROTEC 4 7SD610 (All versions < V4.78), SIPROTEC 4 7SJ61 (All versions), SIPROTEC 4 7SJ62 (All versions), SIPROTEC 4 7SJ63 (All versions), SIPROTEC 4 7SJ64 (All versions), SIPROTEC 4 7SJ66 (All versions), SIPROTEC 4 7SS52 (All versions), SIPROTEC 4 7ST6 (All versions), SIPROTEC 4 7UM61 (All versions), SIPROTEC 4 7UM62 (All versions), SIPROTEC 4 7UT612 (All versions), SIPROTEC 4 7UT613 (All versions), SIPROTEC 4 7UT63 (All versions), SIPROTEC 4 7VE6 (All versions), SIPROTEC 4 7VK61 (All versions), SIPROTEC 4 7VU683 (All versions), SIPROTEC 4 Compact 7RW80 (All versions), SIPROTEC 4 Compact 7SD80 (All versions), SIPROTEC 4 Compact 7SJ80 (All versions), SIPROTEC 4 Compact 7SJ81 (All versions), SIPROTEC 4 Compact 7SK80 (All versions), SIPROTEC 4 Compact 7SK81 (All versions). Affected devices do not properly handle interrupted operations of file transfer. This could allow an unauthenticated remote attacker to cause a denial of service condition. To restore normal operations, the devices need to be restarted.

Action-Not Available
Vendor-Siemens AG
Product-SIPROTEC 4 Compact 7RW80SIPROTEC 4 Compact 7SD80SIPROTEC 4 7VU683SIPROTEC 4 7SA522SIPROTEC 4 6MD63SIPROTEC 4 7SD610SIPROTEC 4 7SA6SIPROTEC 4 7UT612SIPROTEC 4 7UT613SIPROTEC 4 Compact 7SJ80SIPROTEC 4 6MD66SIPROTEC 4 7VK61SIPROTEC 4 Compact 7SK80SIPROTEC 4 6MD61SIPROTEC 4 Compact 7SK81SIPROTEC 4 7ST6SIPROTEC 4 7VE6SIPROTEC 4 7SJ66SIPROTEC 4 6MD665SIPROTEC 4 7SD5SIPROTEC 4 7UT63SIPROTEC 4 7SJ61SIPROTEC 4 7SJ62SIPROTEC 4 7SS52SIPROTEC 4 7SJ63SIPROTEC 4 7UM61SIPROTEC 4 7UM62SIPROTEC 4 Compact 7SJ81SIPROTEC 4 7SJ64
CWE ID-CWE-754
Improper Check for Unusual or Exceptional Conditions
CVE-2022-31810
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.34% / 56.34%
||
7 Day CHG~0.00%
Published-11 Jul, 2023 | 09:07
Updated-05 Mar, 2025 | 18:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SiPass integrated (All versions < V2.90.3.8). Affected server applications improperly check the size of data packets received for the configuration client login, causing a stack-based buffer overflow. This could allow an unauthenticated remote attacker to crash the server application, creating a denial of service condition.

Action-Not Available
Vendor-Siemens AG
Product-sipass_integratedSiPass integrated
CWE ID-CWE-20
Improper Input Validation
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-30938
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-1.83% / 82.18%
||
7 Day CHG~0.00%
Published-12 Jul, 2022 | 10:06
Updated-03 Aug, 2024 | 07:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in EN100 Ethernet module DNP3 IP variant (All versions), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.40), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). Affected applications contains a memory corruption vulnerability while parsing specially crafted HTTP packets to /txtrace endpoint manupulating a specific argument. This could allow an attacker to crash the affected application leading to a denial of service condition

Action-Not Available
Vendor-Siemens AG
Product-en100_ethernet_module_iec_104_firmwareen100_ethernet_module_profinet_io_firmwareen100_ethernet_module_dnp3_ip_firmwareen100_ethernet_module_iec_61850_firmwareen100_ethernet_moduleen100_ethernet_module_modbus_tcp_firmwareEN100 Ethernet module IEC 104 variantEN100 Ethernet module PROFINET IO variantEN100 Ethernet module DNP3 IP variantEN100 Ethernet module Modbus TCP variantEN100 Ethernet module IEC 61850 variant
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-33737
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.23% / 45.55%
||
7 Day CHG~0.00%
Published-14 Sep, 2021 | 10:47
Updated-03 Aug, 2024 | 23:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC CP 343-1 (incl. SIPLUS variants) (All versions), SIMATIC CP 343-1 Advanced (incl. SIPLUS variants) (All versions), SIMATIC CP 343-1 ERPC (All versions), SIMATIC CP 343-1 Lean (incl. SIPLUS variants) (All versions), SIMATIC CP 443-1 (All versions < V3.3), SIMATIC CP 443-1 (All versions < V3.3), SIMATIC CP 443-1 Advanced (All versions < V3.3), SIPLUS NET CP 443-1 (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (All versions < V3.3). Sending a specially crafted packet to port 102/tcp of an affected device could cause a denial of service condition. A restart is needed to restore normal operations.

Action-Not Available
Vendor-Siemens AG
Product-simatic_cp_343-1_erpc_firmwaresimatic_cp_343-1_leansimatic_cp343-1_advancedsimatic_cp_443-1simatic_cp_443-1_advanced_firmwaresimatic_cp_343-1_erpcsimatic_cp_443-1_firmwaresimatic_cp_343-1_advanced_firmwaresimatic_cp343-1simatic_cp_343-1_lean_firmwaresimatic_cp_443-1_advancedsimatic_cp_343-1_firmwareSIMATIC CP 343-1 (incl. SIPLUS variants)SIMATIC CP 343-1 ERPCSIMATIC CP 443-1 AdvancedSIPLUS NET CP 443-1 AdvancedSIMATIC CP 343-1 Lean (incl. SIPLUS variants)SIMATIC CP 443-1SIPLUS NET CP 443-1SIMATIC CP 343-1 Advanced (incl. SIPLUS variants)
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2021-31890
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-2.50% / 84.72%
||
7 Day CHG~0.00%
Published-09 Nov, 2021 | 11:32
Updated-11 Mar, 2025 | 09:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions < V1.0.0.0). The total length of an TCP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on the network buffer organization in memory. (FSMD-2021-0017)

Action-Not Available
Vendor-Siemens AG
Product-nucleus_readystart_v3talon_tc_compactnucleus_nettalon_tc_compact_firmwareapogee_pxc_compactapogee_modular_equiment_controller_firmwareapogee_pxc_compact_firmwareapogee_modular_equiment_controllerapogee_modular_building_controllercapital_vstarapogee_pxc_modular_firmwareapogee_pxc_modularnucleus_readystart_v4talon_tc_modular_firmwaretalon_tc_modularapogee_modular_building_controller_firmwarenucleus_source_codePLUSCONTROL 1st GenSIMOTICS CONNECT 400Capital Embedded AR Classic 431-422Capital Embedded AR Classic R20-11
CWE ID-CWE-240
Improper Handling of Inconsistent Structural Elements
CVE-2021-31401
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-0.71% / 71.40%
||
7 Day CHG~0.00%
Published-19 Aug, 2021 | 11:25
Updated-03 Aug, 2024 | 22:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in tcp_rcv() in nptcp.c in HCC embedded InterNiche 4.0.1. The TCP header processing code doesn't sanitize the value of the IP total length field (header length + data length). With a crafted IP packet, an integer overflow occurs whenever the value of the IP data length is calculated by subtracting the length of the header from the total length of the IP packet.

Action-Not Available
Vendor-hcc-embeddedn/aSiemens AG
Product-sentron_3wa_com190_firmwaresentron_3wl_com35_firmwaresentron_3wa_com190sentron_3wl_com35nichestackn/a
CWE ID-CWE-20
Improper Input Validation
CVE-2024-46891
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-6.9||MEDIUM
EPSS-0.19% / 40.95%
||
7 Day CHG~0.00%
Published-12 Nov, 2024 | 12:49
Updated-20 Aug, 2025 | 19:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 3). The affected application does not properly restrict the size of generated log files. This could allow an unauthenticated remote attacker to trigger a large amount of logged events to exhaust the system's resources and create a denial of service condition.

Action-Not Available
Vendor-Siemens AG
Product-sinec_insSINEC INSsinec_ins
CWE ID-CWE-125
Out-of-bounds Read
CWE ID-CWE-400
Uncontrolled Resource Consumption
CVE-2021-25659
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.44% / 62.47%
||
7 Day CHG~0.00%
Published-10 Aug, 2021 | 10:35
Updated-03 Aug, 2024 | 20:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Automation License Manager 5 (All versions), Automation License Manager 6 (All versions < V6.0 SP9 Update 2). Sending specially crafted packets to port 4410/tcp of an affected system could lead to extensive memory being consumed and as such could cause a denial-of-service preventing legitimate users from using the system.

Action-Not Available
Vendor-Siemens AG
Product-automation_license_managerAutomation License Manager 5Automation License Manager 6
CWE ID-CWE-400
Uncontrolled Resource Consumption
CVE-2021-25676
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.24% / 47.34%
||
7 Day CHG~0.00%
Published-15 Mar, 2021 | 17:03
Updated-03 Aug, 2024 | 20:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM RM1224 (V6.3), SCALANCE M-800 (V6.3), SCALANCE S615 (V6.3), SCALANCE SC-600 (All Versions >= V2.1 and < V2.1.3). Multiple failed SSH authentication attempts could trigger a temporary Denial-of-Service under certain conditions. When triggered, the device will reboot automatically.

Action-Not Available
Vendor-Siemens AG
Product-scalance_s615scalance_m-800_firmwarescalance_sc-600scalance_sc-600_firmwareruggedcom_rm1224_firmwarescalance_m-800scalance_s615_firmwareruggedcom_rm1224SCALANCE M-800RUGGEDCOM RM1224SCALANCE S615SCALANCE SC-600
CWE ID-CWE-307
Improper Restriction of Excessive Authentication Attempts
CVE-2020-9327
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-1.40% / 79.66%
||
7 Day CHG~0.00%
Published-21 Feb, 2020 | 21:25
Updated-04 Aug, 2024 | 10:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In SQLite 3.31.1, isAuxiliaryVtabOperator allows attackers to trigger a NULL pointer dereference and segmentation fault because of generated column optimizations.

Action-Not Available
Vendor-sqliten/aNetApp, Inc.Oracle CorporationCanonical Ltd.Siemens AG
Product-sinec_infrastructure_network_servicesubuntu_linuxcommunications_messaging_servercloud_backupsqlitecommunications_network_charging_and_controlzfs_storage_appliance_kitoutside_in_technologyhyperion_infrastructure_technologyenterprise_manager_ops_centermysql_workbenchn/a
CWE ID-CWE-476
NULL Pointer Dereference
CVE-2024-37994
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-5.3||MEDIUM
EPSS-0.15% / 36.72%
||
7 Day CHG~0.00%
Published-10 Sep, 2024 | 09:36
Updated-18 Sep, 2024 | 15:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC Reader RF610R CMIIT (6GT2811-6BC10-2AA0) (All versions < V4.2), SIMATIC Reader RF610R ETSI (6GT2811-6BC10-0AA0) (All versions < V4.2), SIMATIC Reader RF610R FCC (6GT2811-6BC10-1AA0) (All versions < V4.2), SIMATIC Reader RF615R CMIIT (6GT2811-6CC10-2AA0) (All versions < V4.2), SIMATIC Reader RF615R ETSI (6GT2811-6CC10-0AA0) (All versions < V4.2), SIMATIC Reader RF615R FCC (6GT2811-6CC10-1AA0) (All versions < V4.2), SIMATIC Reader RF650R ARIB (6GT2811-6AB20-4AA0) (All versions < V4.2), SIMATIC Reader RF650R CMIIT (6GT2811-6AB20-2AA0) (All versions < V4.2), SIMATIC Reader RF650R ETSI (6GT2811-6AB20-0AA0) (All versions < V4.2), SIMATIC Reader RF650R FCC (6GT2811-6AB20-1AA0) (All versions < V4.2), SIMATIC Reader RF680R ARIB (6GT2811-6AA10-4AA0) (All versions < V4.2), SIMATIC Reader RF680R CMIIT (6GT2811-6AA10-2AA0) (All versions < V4.2), SIMATIC Reader RF680R ETSI (6GT2811-6AA10-0AA0) (All versions < V4.2), SIMATIC Reader RF680R FCC (6GT2811-6AA10-1AA0) (All versions < V4.2), SIMATIC Reader RF685R ARIB (6GT2811-6CA10-4AA0) (All versions < V4.2), SIMATIC Reader RF685R CMIIT (6GT2811-6CA10-2AA0) (All versions < V4.2), SIMATIC Reader RF685R ETSI (6GT2811-6CA10-0AA0) (All versions < V4.2), SIMATIC Reader RF685R FCC (6GT2811-6CA10-1AA0) (All versions < V4.2), SIMATIC RF1140R (6GT2831-6CB00) (All versions < V1.1), SIMATIC RF1170R (6GT2831-6BB00) (All versions < V1.1), SIMATIC RF166C (6GT2002-0EE20) (All versions < V2.2), SIMATIC RF185C (6GT2002-0JE10) (All versions < V2.2), SIMATIC RF186C (6GT2002-0JE20) (All versions < V2.2), SIMATIC RF186CI (6GT2002-0JE50) (All versions < V2.2), SIMATIC RF188C (6GT2002-0JE40) (All versions < V2.2), SIMATIC RF188CI (6GT2002-0JE60) (All versions < V2.2), SIMATIC RF360R (6GT2801-5BA30) (All versions < V2.2). The affected application contains a hidden configuration item to enable debug functionality. This could allow an attacker to gain insight into the internal configuration of the deployment.

Action-Not Available
Vendor-Siemens AG
Product-simatic_reader_rf650r_fcc_firmwaresimatic_reader_rf680r_cmiitsimatic_rf1170r_firmwaresimatic_reader_rf650r_cmiit_firmwaresimatic_reader_rf685r_fccsimatic_reader_rf650r_aribsimatic_reader_rf615r_etsi_firmwaresimatic_rf360rsimatic_reader_rf680r_fccsimatic_reader_rf610r_fccsimatic_reader_rf610r_etsi_firmwaresimatic_reader_rf685r_arib_firmwaresimatic_reader_rf615r_cmiitsimatic_rf186c_firmwaresimatic_reader_rf685r_fcc_firmwaresimatic_rf188c_firmwaresimatic_reader_rf680r_cmiit_firmwaresimatic_reader_rf685r_etsisimatic_rf185csimatic_rf360r_firmwaresimatic_rf1140r_firmwaresimatic_rf186cisimatic_rf1140rsimatic_rf188csimatic_reader_rf610r_cmiit_firmwaresimatic_reader_rf610r_fcc_firmwaresimatic_rf185c_firmwaresimatic_reader_rf615r_fccsimatic_reader_rf680r_etsisimatic_reader_rf615r_fcc_firmwaresimatic_reader_rf680r_fcc_firmwaresimatic_reader_rf610r_etsisimatic_reader_rf685r_cmiit_firmwaresimatic_reader_rf680r_arib_firmwaresimatic_rf186ci_firmwaresimatic_rf166c_firmwaresimatic_rf188ci_firmwaresimatic_reader_rf650r_fccsimatic_reader_rf650r_cmiitsimatic_reader_rf685r_cmiitsimatic_rf166csimatic_reader_rf680r_aribsimatic_rf1170rsimatic_reader_rf650r_etsisimatic_reader_rf610r_cmiitsimatic_reader_rf650r_arib_firmwaresimatic_reader_rf680r_etsi_firmwaresimatic_reader_rf615r_etsisimatic_reader_rf650r_etsi_firmwaresimatic_rf186csimatic_reader_rf685r_aribsimatic_reader_rf615r_cmiit_firmwaresimatic_reader_rf685r_etsi_firmwaresimatic_rf188ciSIMATIC Reader RF650R ARIBSIMATIC Reader RF650R ETSISIMATIC Reader RF680R CMIITSIMATIC Reader RF615R ETSISIMATIC RF166CSIMATIC Reader RF685R CMIITSIMATIC RF185CSIMATIC Reader RF610R CMIITSIMATIC Reader RF685R ETSISIMATIC Reader RF615R CMIITSIMATIC RF188CISIMATIC Reader RF610R ETSISIMATIC Reader RF685R FCCSIMATIC Reader RF615R FCCSIMATIC RF186CSIMATIC RF360RSIMATIC Reader RF680R ARIBSIMATIC RF1140RSIMATIC Reader RF685R ARIBSIMATIC RF1170RSIMATIC Reader RF680R ETSISIMATIC RF188CSIMATIC Reader RF610R FCCSIMATIC Reader RF650R CMIITSIMATIC RF186CISIMATIC Reader RF680R FCCSIMATIC Reader RF650R FCC
CWE ID-CWE-912
Hidden Functionality
CVE-2024-33583
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-4.8||MEDIUM
EPSS-0.11% / 30.47%
||
7 Day CHG~0.00%
Published-14 May, 2024 | 10:03
Updated-02 Aug, 2024 | 02:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected application contains a hidden configuration item to enable debug functionality. This could allow an authenticated local attacker to gain insight into the internal configuration of the deployment.

Action-Not Available
Vendor-Siemens AG
Product-SIMATIC RTLS Locating Managersimatic_rtls_locating_manager
CWE ID-CWE-912
Hidden Functionality
CVE-2024-37990
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-7||HIGH
EPSS-0.20% / 42.73%
||
7 Day CHG~0.00%
Published-10 Sep, 2024 | 09:36
Updated-18 Sep, 2024 | 15:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC Reader RF610R CMIIT (6GT2811-6BC10-2AA0) (All versions < V4.2), SIMATIC Reader RF610R ETSI (6GT2811-6BC10-0AA0) (All versions < V4.2), SIMATIC Reader RF610R FCC (6GT2811-6BC10-1AA0) (All versions < V4.2), SIMATIC Reader RF615R CMIIT (6GT2811-6CC10-2AA0) (All versions < V4.2), SIMATIC Reader RF615R ETSI (6GT2811-6CC10-0AA0) (All versions < V4.2), SIMATIC Reader RF615R FCC (6GT2811-6CC10-1AA0) (All versions < V4.2), SIMATIC Reader RF650R ARIB (6GT2811-6AB20-4AA0) (All versions < V4.2), SIMATIC Reader RF650R CMIIT (6GT2811-6AB20-2AA0) (All versions < V4.2), SIMATIC Reader RF650R ETSI (6GT2811-6AB20-0AA0) (All versions < V4.2), SIMATIC Reader RF650R FCC (6GT2811-6AB20-1AA0) (All versions < V4.2), SIMATIC Reader RF680R ARIB (6GT2811-6AA10-4AA0) (All versions < V4.2), SIMATIC Reader RF680R CMIIT (6GT2811-6AA10-2AA0) (All versions < V4.2), SIMATIC Reader RF680R ETSI (6GT2811-6AA10-0AA0) (All versions < V4.2), SIMATIC Reader RF680R FCC (6GT2811-6AA10-1AA0) (All versions < V4.2), SIMATIC Reader RF685R ARIB (6GT2811-6CA10-4AA0) (All versions < V4.2), SIMATIC Reader RF685R CMIIT (6GT2811-6CA10-2AA0) (All versions < V4.2), SIMATIC Reader RF685R ETSI (6GT2811-6CA10-0AA0) (All versions < V4.2), SIMATIC Reader RF685R FCC (6GT2811-6CA10-1AA0) (All versions < V4.2), SIMATIC RF1140R (6GT2831-6CB00) (All versions < V1.1), SIMATIC RF1170R (6GT2831-6BB00) (All versions < V1.1), SIMATIC RF166C (6GT2002-0EE20) (All versions < V2.2), SIMATIC RF185C (6GT2002-0JE10) (All versions < V2.2), SIMATIC RF186C (6GT2002-0JE20) (All versions < V2.2), SIMATIC RF186CI (6GT2002-0JE50) (All versions < V2.2), SIMATIC RF188C (6GT2002-0JE40) (All versions < V2.2), SIMATIC RF188CI (6GT2002-0JE60) (All versions < V2.2), SIMATIC RF360R (6GT2801-5BA30) (All versions < V2.2). The affected applications contain configuration files which can be modified. An attacker with privilege access can modify these files and enable features that are not released for this device.

Action-Not Available
Vendor-Siemens AG
Product-simatic_reader_rf650r_fcc_firmwaresimatic_reader_rf680r_cmiitsimatic_rf1170r_firmwaresimatic_reader_rf650r_cmiit_firmwaresimatic_reader_rf685r_fccsimatic_reader_rf650r_aribsimatic_reader_rf615r_etsi_firmwaresimatic_rf360rsimatic_reader_rf680r_fccsimatic_reader_rf610r_fccsimatic_reader_rf610r_etsi_firmwaresimatic_reader_rf685r_arib_firmwaresimatic_reader_rf615r_cmiitsimatic_rf186c_firmwaresimatic_reader_rf685r_fcc_firmwaresimatic_rf188c_firmwaresimatic_reader_rf680r_cmiit_firmwaresimatic_reader_rf685r_etsisimatic_rf185csimatic_rf360r_firmwaresimatic_rf1140r_firmwaresimatic_rf186cisimatic_rf1140rsimatic_rf188csimatic_reader_rf610r_cmiit_firmwaresimatic_reader_rf610r_fcc_firmwaresimatic_rf185c_firmwaresimatic_reader_rf615r_fccsimatic_reader_rf680r_etsisimatic_reader_rf615r_fcc_firmwaresimatic_reader_rf680r_fcc_firmwaresimatic_reader_rf610r_etsisimatic_reader_rf685r_cmiit_firmwaresimatic_reader_rf680r_arib_firmwaresimatic_rf186ci_firmwaresimatic_rf166c_firmwaresimatic_rf188ci_firmwaresimatic_reader_rf650r_fccsimatic_reader_rf650r_cmiitsimatic_reader_rf685r_cmiitsimatic_rf166csimatic_reader_rf680r_aribsimatic_rf1170rsimatic_reader_rf650r_etsisimatic_reader_rf610r_cmiitsimatic_reader_rf650r_arib_firmwaresimatic_reader_rf680r_etsi_firmwaresimatic_reader_rf615r_etsisimatic_reader_rf650r_etsi_firmwaresimatic_rf186csimatic_reader_rf685r_aribsimatic_reader_rf615r_cmiit_firmwaresimatic_reader_rf685r_etsi_firmwaresimatic_rf188ciSIMATIC Reader RF650R ARIBSIMATIC Reader RF650R ETSISIMATIC Reader RF680R CMIITSIMATIC Reader RF615R ETSISIMATIC RF166CSIMATIC Reader RF685R CMIITSIMATIC RF185CSIMATIC Reader RF610R CMIITSIMATIC Reader RF685R ETSISIMATIC Reader RF615R CMIITSIMATIC RF188CISIMATIC Reader RF610R ETSISIMATIC Reader RF685R FCCSIMATIC Reader RF615R FCCSIMATIC RF186CSIMATIC RF360RSIMATIC Reader RF680R ARIBSIMATIC RF1140RSIMATIC Reader RF685R ARIBSIMATIC RF1170RSIMATIC Reader RF680R ETSISIMATIC RF188CSIMATIC Reader RF610R FCCSIMATIC Reader RF650R CMIITSIMATIC RF186CISIMATIC Reader RF680R FCCSIMATIC Reader RF650R FCC
CWE ID-CWE-912
Hidden Functionality